Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Accepted-AOC | |
| 2 | L2₹44.2 L+₹2.6 L (6.19%)Rejected-AOC | L2 | Rejected-AOC Rejected-AOC | |
| 3 | L3₹44.8 L+₹3.2 L (7.61%)Rejected-AOC LANE NO 11 HOUSE NO 4 INDRAPRASTHA COLONY UPPER NATHANPUR RING ROAD DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC Rejected-AOC | |
| 4 | L4₹46.0 L+₹4.3 L (10.4%)Rejected-AOC | L4 | Rejected-AOC Rejected-AOC | |
| 5 | L5₹48.4 L+₹6.8 L (16.3%)Rejected-AOC | L5 | Rejected-AOC Rejected-AOC |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
16 Dec 2020, 6:00 pmClosed
GE DEHRADUN
GE DEHRADUN, MALL ROAD, GARHI CANTT, TELE - 01352750580
Spl repair to 01 x Septic tank of OR Govt Md Accn Bldg No P-1, P-2, P-18 and P-19 at Sulva line of 2/5 GR (FF) at Ghunghora, Single JCOs Accn Bldg No. T-1 of 217 Fd Wksp Coy EME, sewer pipe line (approx 280 RM) and repair of septic tank roofs, manhol
2020_MES_395670_1
8244/A/E8
Open Tender
Civil Works
Item Rate
120 days
GE DEHRADUN
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹99,000
Yes
23 Feb 2021
17 Nov 2020
18 Dec 2020
17 Nov 2020
16 Dec 2020
2 Dec 2020
Amount
Demolition of brick work or stone/boulder, masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but exceeding ashlar facing and pre-cast concrete articles complete all as specified and as directed
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable to store and rabbish off the premises.
Demolition of RCC of any description and in any position not otherwise specifically provided complete all as specified and as directed
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified
M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre means radius built in cement mortar 1:6 complete all as specified and as directed.
All as per item No 5.00 here in above but except bricks (Bricks shall be reused, obtained from demolition of brick work)
M&L Brickwork with subclass ‘B’ bricks in cement mortar 1:4, straight or curved on plan exc 6mtrs radius complete all as specified and directed.
Taking down cement plaster on brick wall including racking out joints, hacking for key, scrubbing down with water complete all as specified
M&L for rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:3) finished surfaces even and smooth complete all as specified and as directed.
M&L rendering 15m thick on fair faces of brick work in CM 1:6 and finished surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
M&L rendering 15m thick on fair faces of brick work in CM 1:4 and finished surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
Supply only liquid water proofing compound as per manufacturer's instructions . Make- Pidilite/fosrock/bauchemic/Sika.
M&L for 25 mm thick plain cement concrete (1:2:4) type B-0 ( using 12.5 mm graded stone aggregate) as in sub base of floor finished complete all as specified
M&L non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exceeding 0.11sqm but n.exc 0.18sqm in floor etc, set and jointed in neat cement slurry and pointed in white cement mixed with colour pigment to match including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M&L for coloured Non Skid Ceramic joint free tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with colour pigment to match including screed bed 15mm thick in CM (1:6) all as directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 350x250x7mm/ 450x350x7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white cement mixed with coloured pigment to match all as directed.
M&L 15 to 18 mm thick machine cut polished granite 1st quality "black" stone slab over kitchen platform, steps and similar placed over and including 15mm thick screed bed in cement mortar (1:4) laind and jointed with white cement with admixture of marble dust in ratio (1:2) mixed with pigment to match with existing surface including grinding and moulding of exposed edges of granite complete all as specified and directed.
M&L 65-70 mm thick Pre-Cast Factory made RCC M-30 as in Cover slab in different size of Manholes, Septic tanks or Similar articles with Plain faces all round 1mm thick plain sheet on the edge painted with bituminous paint on external surface and RCC cover should be engraved CA No and MES and set in cement mortar (1:4) with Nos 12 mm dia handle counter sunk, complete all as specified and directed by Engr-in-Charge.
Rounding to edges of stone slabs one edge ,of any situations complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness incl cover fillets.
Providing and fixing tiled false ceiling of Everest Designer tile lvory plainted (High pressure steam cured) of 4 mm thickness (as per IS 14862) of size 595x595mm and any one of the design (cascade of electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gsm, both side inclusive and black painted groove on all T webs) consisting of main "T" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30mm sheet, 1200mm long spaced between main "T" at 600mm c/c to from a grid of 1200 x 600 mm and secondary cross "T" of length 600mm and size 15 x 32 mm made of 0.30mm thick sheet to be interolcked at middle of
Item No 21.00 contd/....the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, rquired cutting/ making opening for services like diffusers, grills light fittings, fixtures smoke detectors etc. Main "T" runners to be suspended from ceiling using CI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adustable rods of 3 mm dia with galvanized butterfly level clips or with 3 mm dia GI wire, spaced at 1200mm c/c along main "T" bottom exposed width of 15mm of all T Section shall b pre painted with polyster paint and black painted groove at center or size 4mm depth and 4mm all complete all as specified by Engr-in-Charge. including dismantling of old celing board inclduing cover fillets and removing from site.
Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frame) and removing from site complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm but n exc 4 Sqm each (without taking off shutters from the frame) and removing from site complete all as specified and directed.
M&L for 2nd class hard wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S&F pre laminated Solid PVC Door frame of size 50mm x 47mm made out of 5mm single side prelam single piece extruded pvc profile and edgs will be painted to match with prelam sheet , PVC sheet are to be reinforced with 19x19mm MS square tube EPDM rubber gasket weather seal shall be provided through out the frame. The profile shall be mitre cut at two corners and joint by insrting 2 nos of 150mm long backets of 15mmx15mm MS square tube inside the 19mmx19mm MS square tube and suitably screwed and fixing in opening as per specification & drawing.
S&F Factory made solid PVC Moulded Door Shutter, 28 to 30 mm thick (stiles) with 2,4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm Plain colour PVC sheet on back face, supplying & fixing in the frame at site as per specification complete all as specified and as directed by Engr-in-Charge.
S&F for 35mm thick flush shutters, solid core constructor with block board core and plywood face panel and commercial type on both side, including provision of block suitable for taking mortice lock, latches and other fitting complete all as specified and directed.
S&F powder coated aluminium anodised door with frame, shutter, following accessories and glazing 4.8mm thick retro reflected glass, rubber gasket, aluminium glazing clips, mortice lock, aluminium stopper cleat, iron mongary section of aluminium door shall be of following sizes:- Frame : 100x44x1.2mm thick with rawl plug middle lock rail : 85x44x1.20mm thick Bottom rail : 150x44x1.20mm thick Top rail : 85x44x1.20mm thick Style : 75x44x1.20mm glazing bead : 070 mm thick aluminium handle 'D' type 150mm, aluminium tower bolt 9.9mm dia shoot 200mm long Mortice lock : 100mm 4 lever, aluminium stopper cleat aluminium hinges 100mm long (Note : PCC shall be measured and paid separately and making good of wall surface with matching to existing surface complete all as specified and directed.
S&F for 35 mm thick 2nd class hard wood factory made glazed and skeleton shutters , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24(a); supplied and fitted to chowkhats complete all as specified and directed.
S&F 150 mm long aluminum anodised tower Bolt fixed with screw complete all as specified and directed by Engr-in-charge
S&F 150mm long Aluminium, anodised handles of fabricated type complete all as specified and as directed .
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F 100 mm size cadmium plated stainless steel butt hinges and fixed with stainless steel screws, complete all as specified and directed.
S&F 250mm long aluminium alloy sliding door bolt, hasp & staple (bolt type) with bright bolt not less than, 12mm dia with an including 6 boths and nuts four on bolt plate and two on staple plate ISI marked complete all as specified.
S&F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F factory fabricated steel windows with side hung shutters including box type hinges without glazing bars, including MS handles, peg stay, tower bolts complete all as specified and directed Notes : Wire mesh, glazing & guard bars shall be measured and paid sepearately under respective items of this schedules
S&F in repair factory fabricated steel windows with side hung shutters including box type hinges with glazing bars, including MS handles, peg stay, tower bolts complete all as specified and directed Notes : Wire mesh, glazing & guard bars shall be measured and paid sepearately under respective items of this schedules
S&F in repair factory made steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed Notes : Wire mesh, glazing & guard bars shall be measured and paid sepearately under respective items of this schedules
S&F framed work such as grills grating etc with end of bars shoulderedor riveted, or forged into spikes, frmaed guard bars, barred iron doors and similar work conforming to Fe-210, Gde E-165 complete all as specified and directed.
M&L sheet glass ordinary quality 4 mm thick, glazing with oil putty with glazing pins in squares exc 0.50 sqm each pane complete all as specified and directed.
M&L sheet glass frosted ordinary quality 4 mm thick, glazing with oil putty with glazing pins/rubber gasket in squares n.exc 0.50 sqm each pane as in aluminium window complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned tacks or stainless steel wire staples all as directed by Engeer-in-charge.
S&F in repair 20mm dia mild steel curtain rail, chromium plated with fixing brackets, stops, rollers etc fixed to walls complete all as specified and directed.
M&L for two coat of synthetic enamel paint over a coat of primer including preparation on new steel surfaces of any description over 10 cm width or girth complete all as specified.
M&L for new surfaces of any description ,over 10cm in width or girth preparation, filling with thin varnish or lacquer shellack varnish , under coating and finishing with synthetic varnish complete all as specified and directed.
M&L for complete removal of existing treatment of wall preparing surfaces and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L for preparation of wall and applying interior grade wall care putty 2 to 3mm thick to make the surface smooth as specified and directed by Engr-in-Charge
M&L for preparation of old plastered /POP/ putty surfaces of walls and applying two coats of cement base paint complete all as specified and directed by Engr-in-charge
M&L for preparation of new plastered /POP/ putty surfaces of walls and applying two coats of cement base paint over a coat of suitable primer complete all as specified and directed by Engr-in-charge
Taking up or down steel tubing and connection incl removal from site bore of pipe 15 mm.
Taking up or down steel tubing and connection incl removal from site bore of pipe 20 mm.
M&L for preparation of new surface, plaster/un-plaster and applying two coats of oil bound distemper over a coat of suitable primer complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills sunshades, shelves, lintel,etc and cutting chases for cocealed water tubing or concealed conduit wiring, etc and making, googd, cutting n exc 10 cm girth complete all as specified and directed.
M&L steel water tubing 15 mm bore medium grade galvanized with all fittings such as bends, tees, nipples, elbows, reducers, etc, fixed complete to walls and ceilings or laid in floors all as specified and directed.
M&L steel water tubing 20 mm bore medium grade galvanized with all fittings such as bends, tees, nipples, elbows, reducers, etc, fixed complete to walls and ceilings or laid in floors all as specified and directed.
Dismantling water tanks of any description and removing from site exc 500 and n exc 1000 ltr capacity complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks 500 Ltrs capacity three layered, externally white (cylindrical vertical with closed top) hoisted and fixed in position including PTMT ball valve 20mm bore with polythelene float complete all as specified and directed.
S&F gun metal globe or gate valve, with iron wheel suitable for 20mm bore iron pipe complete all as specified.
S&F in repairs ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for 20mm bore iron pipe ( minimum weight 20mm -210 gms) complete all as specified and directed.
S&F vitreous china wash hand basin, white flat back, size 440x550mm excluding taps but including waste pipe, CP waste fittings 32mm size long shank,brass and MS brackets all as specified and directed by Engr-in-charge Make: Make :Jaquar FNS-WHT-40801 or equvilant of Hindware /Parryware FNS-WHT-40801
S& Pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make : Jaquar Cat part No. VGP81001 / Hindware -F370001 / Parryware -EDGE G4802A1.
S&F 32mm dia bore waste fittings brass chromium plated fixed to wash hand basin, sinks with long screwed shanks and fly nuts flange and bedded in run lead cement and other fixed complete all as specified and directed.
S&F 32mm bore PTMT wash hand basin waste pipe complete all as specified and directed.
S&F in repair vitreous china squatting pan Orrisa pattern of size 580x440mm white with integral foot rest including connecting to trap and anti-syphonage pipe incl provision of lime concrete bedding and making good to floor complete all as specified and directed.Make:- Hindware (CONMFORT) cat No. 20070/ Cera cat No. S3010106(OR)/Jaquar Cat No.ECS-WHT-453LE .
S&F in repair 10 ltr capacity PVC low level flushing cistern including PVC syphon and float valve with PVC long band for out let connection of cistern with WC, complete all as specified and directed (Make commander/Cera/Hindware).
S&F in repair 15mm nominal internal bore PVC connection 450mm long with two brass nuts and PVC washer complete all as specifed
S&F in repair 15mm bore Bib taps, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed Make : - JAGUAR CAT Part No ALI-85037/Hindweare CAT Part No F-370004/Parryware
S&F in repair 20 mm dia brass chromium plated tubular towel rail, D type, 60 cm long between flanges fixed with rawl plug complete all as specified and directed.
S&F in repair 15mm Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specifed .Make :Jaquar cat No- EOS-538 RB or equivalent in Hindware/Parryware
S&F grating doom 100mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed.
S&F grating doom 125mm dia with waste hole of PTMT (minimum weight 40gms) complete all as specified and directed.
S&F in repair PTMT shelf fixed with and including chromium plated brass screws and wooden/ plastic cleats (minimum weight 300gms) complete all as specified and directed.
S&F in repair stainless steel sink with draining board made out of 1mm thick sheet kitchen or laboratory with plugs, washers including beding lime cement mortar to dwarf wall or including fixing cantilever brackets fixed to wall and connecting union to pipe overall size 914x460x203mm bowl size 405x354x203 mm complete all as specified and directed.
Taking down rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc including cleaning or refixing or removal to store measured over all as fixed along the center line over fittings and accessories) complete all as specified and directed.
S & F 75 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring,joints laid in trenches complete for the following sizes Make : Supreme/Finolex/Prince
S & F 110 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring,joints laid in trenches complete for the following sizes Make : Supreme/Finolex/Prince
S&F UPVC (SWR) Bend, 'T' junction, socket, reducer, with access door jointed with adhesive for 75 mm bore pipes complete all as specified and directed. Make: Supreme/ Finolex/Prince
S&F UPVC (SWR) Bend, 'T' junction, socket, reducer,with access door jointed with adhesive for 110 mm bore pipes complete all as specified and directed. Make: Supreme/ Finolex/Prince
S&F in repair cast iron bend (any radius) of 75mm bore with oval access door.
S&F in repair 110mm dia cast iron cowls complete all as specified and directed.
S&F 75mm dia PVC floor trap including jointing to waste pipe fixed in cement concrete type B 1(1:2:4) complete all as specified
S&F 75mm dia (spun) cast iron soil and waste pipe in any length with or with ears, with cement joints laid in floors/ trenches complete all as specified and directed.
All as per item No 83.00 here in above but fixed on wall complete all as specified and directed.
S&F in repair 75mm dia cast iron (spun) cowls.
S&F UPVC vent cowl 1103m bore complete all as specified and directed
S&F in repair cast iron (spun) bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door of 100 mm bore
S&F 100mm dia (spun) cast iron soil and waste pipe in any length with or with ears, with cement joints laid in floors/ trenches complete all as specified and directed.
All as per item No 86.00 here in above but fixed on wall complete all as specified and directed.
S&F centrifugally cast (Spun) iron brach piece single of 100mm bore with parallel branches complete all as specified and directed.
S&F centrifugally cast (Spun) iron brach piece single of 75mm bore with parallel branches complete all as specified and directed.
S&F 100mm dia centrifugally cast (spun) iron bends (any radius) diminishing pieces or taper (larger bore measured) complete all as specified and directed.
S&F 75mm dia centrifugally cast (spun) iron bends (any radius) diminishing pieces or taper (larger bore measured) complete all as specified and directed.
M&L for salt glazed stone ware gully traps square or rounded mouthed type 'P' of size 150x150mm embedded in PCC with necessary brick work, plastering etc complete and connection to pipe complete all as specified and directed by Engr-in-Charge
M&L for precast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) in cover slabs ( for manholes etc.) and similar articles with plain faces including necessary form work, set in cement mortar (1:4) complete all as specified and directed.
M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre depth for foundation, manhole etc not exc 10 Sqm on plan and not exc 1.5 metre in depth including getting out in any type of soil complete all as specified and as directed
Excavation over areas not exceeding 1.50 metre depth and getting out in any type of soft/loose soil for septic tank/ sokage well etc complete all as specified and as directed
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil etc,complete all as specified and as directed.
Returning, filling in soil including spreading, leveling watering and well ramming in layers not exceeding 25 centimetre complete all as specified and directed.
Removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed
Removing excavated surplus soil/material not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed
Removing excavated surplus soil/material exc 250 metre and not exceeding 500 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed
Cutting into existing manholes for connecting new drains 150mm bore pipe including removing existing branch drain pipe of 100/150mm bore & benching to form branch channel (1/2 round or 3/4 section) incement concrete (1:2:4) type good surface with plaster etc to match existing , etc complete all as specified and directed.
Demolition and breaking up drain pipes (slat glazed ware, AC or reinforced concrete) set in cement mortar, in 150 mm internal dia complete all as specified and as directed.
M&L Salt Glazed Stone Ware drain pipe, grade ‘A’ 150 mm bore laid in trenches and jointed complete all as specified and as directed. (Excavation and earth work shall be measured and paid separately).
M&L Salt Glazed Stone Ware drain pipe, grade ‘A’ 200 mm bore laid in trenches and jointed complete all as specified and as directed. (Excavation and earth work shall be measured and paid separately).
M&L for concrete in PCC (1:3:6) type C-2 ( using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed .
M&L for concrete in PCC (1:3:6) type C-2 ( using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore pipe complete all as specified and directed .
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in benching and forming fair finished drain or channel using extra cement, including forms, moulds mitered or stopped ends etc. complete., including necessary form work complete all as specified and as directed
M&L PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for foundations, filling and mass concrete etc, complete all as specified and as directed .
M&L for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in surface channel and drains complete all as specified and directed.
M&L 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone agg as in sub base complete all as specified and as directed by the Engr-in-Charge.
M&L for hardcore of broken stone or boulder of gauge exc 63 mm but n.exc 100 mm deposited, spread and leveled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surfaces,complete all as specified and as directed.
M&L for RCC (1:1.5:3) type A-1 (using 20mm graded crushed stone aggregate) as in slab of septic tank/ sokage well etc complete all as specified and directed. (Note : formwork & reinforcement shall be measured and paid separetly).
M & L for Reinforced cement concrete ( 1:1.5:3 ) type A-0 (using 12.5 mm graded stone aggregate) as in baffle wall etc complete all as specified and as directed.
M&L for 50mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor etc, surface finished even and smooth using extra cement etc complete all as specified and directed.
M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/ stopped ends etc complete all as specified and directed.
M&L plain fillets 2nd class hard wood wrought exc 13 & n exc 25 Sqcm (Square or rectangular) in section, secured with nails or barbs all as directed by Engr-in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete.
M&L for formwork to edges of slabs of septic tank/ sokage well n exc 200cm wide, horizontal or sloping & similar work exc 10cm but n exc 20cm wide for fair finished surfaces of concrete etc complete all as specified and directed.
S&F 6mm thick teak wood lipping for fixing on edges of pre laminated particle board/ block board complete all as specified and directed.
M&L for 0.9mm decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
M&L for 18/19 mm thick block boards, grade 2 quality interior grade, decorative type with decorative face veneer on one face fixed with screws to timber frame work complete all as specified and directed.
S & F magnetic catches with 8mm dia steel ball, and brass and striking plate including letting in and fixed
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flap (when open) 30 mm complete all as specified and directed.
S&F 40mm dia cup board knobs brass polished fixed with screw and washers complete all as specified & directed.
S&F Hasp and staple 75 mm safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws
M & L for 75mm thk PCC 1:3:6 type C-2 as in plinth protection, finished even and fair without using extra cement. The plinth protection shall be laid in alternate bays nexe 2 sqm with 10mm wide joints filled with bitumen mastic comprising of 1 part of hot bitumen 85/25 grade and 3 parts sand all by weight complete all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.55mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.55mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified
M&L for pre-polished pavement coloured tiles glossy finish of size not less than 300x300x20-22 mm thick with anti skid properties laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
Dismantling of corrugated or semi corrugated Asbestos Cement (AC) sheets in roof covering incl ridge, velly gutters complete all as specified and directed.
M&L for water proofing treatment on roof slab including picking, sweeping clean and washing down with water to remove dust & providing water proofing treatment described as under:- (a) Surface preparation and treating of construction joints, filling of honey combs with polymer modified mortar (Cement: Sand : smart care multipurpose polymer of Asian Paints or equivalent product of Thermax/ Berger ) (b) Providing PCC (1:2:4) type B-0, 25mm thick screed bed or bedding layer over roof surface .
Item No 134.00 contd. (c) Cleaning the surface and applying (Resin & Hardner) smart care Epoxy Primer 2k of Make Asian paints or equivalent product of Thermax/ Berger ) on the cleaned surface for bonding of PU magnum with the existing concrete surface. (d) Supplying, providing and applying waterproofing treatment to Terrace area with Asian Paints Smart care PU magnum, single component highly elastomeric seamless cold applied modified PU coating or equivalent product of Thermax/ Berger) including all necessary surface preparation, coving using smart care multipurpose polymer, water pond test, etc. complete as per manufacture's specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1mm. The coating shall have dual combination of 250% elongation . Execution to be done with authorised applicator of the manufacturer. Work will be executed in smart assurance system..
Provn of 50 users septic tanks including excavation and earthwork in any type of soil , PCC foundation, brick work, RCC cover slab, precast RCC man hole cover with angle iron frame vent shaft and sludge chambers complete all as shown on TD drawing, specified and directed.
M&L for construction of soakage well, internal dia 1.80M dia & depth 3.00M including excavation and earthwork in any type of soil ,brick work etc,complete all as shown on TD drawing, specified and directed.
M&L for cleaning of existing seawage pipe lines 100mm/150/200mm internal dia at any depth including manholes by removing the manholes cover of any type/ size and cleaning by means of hydraulic jet pressure machine manually as required at site from manholes and well fulshing with water after cleaning including getting out sudge in any and liquid materials from connecting manholes cover to its original position (cost of removal of sludge/ liquid material from sewage lines and manholes in same line is including in rate of this item and rate quoted also includes for keeping particular sewage line which is undertaken once cleaning, functional for full contract period) complete all as specified and directed.
Removing the manholes covers (CI or RCC) any type of manholes rectangular/ circular and de-sludingg / de-watering of septic tank and soakage well of any size and depth by mechanical pumping by plugging intel as required, making it fully functional to the entire satisfaction of Engr-in-Charge including carrying the effluent and re-instating the manoles cover to its original position complete all as specified and directed by Engr-in-Charge.
Cleaning of manhole any depth any size taking out accumulated, soil, sludge any material including both ends and removal to MD lands and manholes cover refixing complete all as specified and directed.
Suncking out sewage water through sewage tanker from the man hole/ septic tank/ soakage well in different location and disposal (5000ltr capacity) of out of MD land complete all as specified and directed.
Dismanlting cast iron or reinforced cement concrete drain pipes jointe in cement mortar and taking out of trenches if required for internal dia of pipe upto 100mm including all fittings complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, lamp holders, regulators, sockets, light fitting any type etc complete. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Eng.-in-charge
M&L for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel suction box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly complete all as specified and directed by Engr.-in-charge of following.
(a) One light /bell / Exhaust fan point controlled by one-one way switch.
(b) One ceiling fan Point controlled by one-one way switch through Regulator.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board.
All as per Item No 143.00 here in above but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete.
S & F Switch piano flush type single pole one way 230 Volts 6 Amp complete all as directed.
S & F Switch piano flush type single pole one way 230 Volts 16 Amp complete all as directed.
S & F Socket outlet ,2 in 1,5 pin , 230 Volts 5 Amp & 15/16 Amps flush type multipurpose complete.
S & F Socket outlet 2 in 1,5 pin , 230 Volts 5/6 Amps flush type multipurpose 5 pin complete.
Supply and fixing Ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified
S&F step type, electronic fan regulator 120 watts, 5 step for ceiling fan 1200/1400 mm sweep 230 volts AC. Make : HPL/ Havells/ Anchor.
S & F Lamp holder polycarbonate insulated body complete all as specified and directed.
S&F MCB, SP, 240 volt,10KA, 10 to 32 Amp, conforming to relevant IS complete all as specified & directed.
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips smart bright/ Crompton LDLB-20-CDL/ Wipro TRM LED as approved by GE
S&F Energy saving Bulk head luminaire with opal diffuser with and including retrofit LED lamp 10 watts complete all as specified and directed by Engr-in-charge. Make : CG cat LBHP-10-CDL/Philips WT140W LED7S CW PSU S1 PC/Havells ENDURA RUGBYNEO N /Bajaj cat no BIBWP10WLED.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with a 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm. dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe medium 15 mm. bore, and water pipe 20 mm. bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & 75 mm thick RCC (1:2:4) type B1 cover slab reinforced with 8mm TMT bars 100mm c/c both ways complete all as specified & shown in elect plate No. 3 of SSR part I of 2009 and testing on completion. Note: (i) If the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item
Supply & fixing vibration free exhaust fans AC single phase 230/ 240 V of size 300 mm sweep double ball 900 rpm with louvers making necessary fixing arrangements on wall with hold fasteners 4 Nos nut and bolts connecting with three core flexible copper conductor cable (23/0.0060) from ceiling rose complete all as specified and directed. Make: Orient/Havells/CG
Supply & fix fans ceiling complete with blades, 230 V,1200 mm sweep, White/Brown/lvory, complete all as specified and directed. , make: Havells,Usha,Orient
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 16 Sqmm 4core inclu lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-charge. Make: Havells/Polycab/Glandlay
M&L for sand cushioning in trenches for protection of UG cable with river bed sand laid dry in trenches before and after laying of cable, including well ramming and consolidation complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Supply and laying GI Steel tubing light grade 40 mm dia including all fitting laying in trenches or grouting/fixing in wall for protection of cable in replacement , complete all as specified and directed by Engineer-in-charge
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) and one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4 Sq mm as earth wire upto common earth and connected to earth dolly drawing through and including 20 mm dia medium density concealled PVC conduit pipe, ,complete all as specified & directed. Make: Havells/Finolex/L&T
S&F Geyser Vertical Storage type of capacity 50 Ltrs ISI marked having Stainless steel storage tank of capacity 50 ltrs, rock wool insulation, 2.0 KW element, thermostat, system On/Off indicator lamps, safety valve, pressure release valve, inlet & outlet connections with suitable size hot and cold nylone braided pipes 2 Nos connected to water supply line complete including three core power cord with , having minimum 5 star rating as per BEE certification including grouting of four nos hold fastners/Tee bolts of suitable size etc for fixing of geyser to wall complete all as specified and directed Make : Racold CDR 50V or equivalent in Havells/Crompton/AO Smith/Jaquar
M&L for Distribution board Vertical type TPN 4 Way double door, suitable for MCCB 100/125 Amps MCCB as incoming and MCBs for outgoing factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection incl taking out old u/s complete. Note:- DB and MCCB/MCB shall be of same make and paid separetaly Make:- Legrand/Hager/L&T /C&S
Supply and fixing of MCCB 100 Amps FP 415 Volts having breaking capacity 15 KA with and incl spreader link kit complete suitable for fixing as incoming in polycarbonate busbar complete all as specified and directed.
S&F in replacement Sheet metal enclosure SPN with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 10 KA C series complete all as specrified & directed Make: Legrand / L&T/ Schneider.
S&F street light fitting LED type 60 Watt of dia-cast IP 66 aluminium housing, 60 watt, LED 6000K lence type toughened glass having separate surge protector 10 KV,efficiency of minimum 100 lumens/watt, incl adopter( if any) required to fixed with replacement of MS bracket 40 mm dia incl clamps with painted all as directed. Make : Green star/ Phillips/ HaveIIS/ Crompton
Ram Naresh Singh Sikarwar
M/s Teg Singh Negi
RAMAPATI ENGINEERING SERVICES
M/S C S AITHANI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .