| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹17.8 L+₹2.1 L (13.3%)Rejected-Finance 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹29.6 L+₹13.9 L (88.3%)Rejected-Finance 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L3 | Rejected-Finance BEING L3 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
6 Oct 2023, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIRS / DAY TO DAY MAINT OF STREET LIGHT / SOLAR STREET / POLE / CABLE JUNCTION BOX / TIMER SWITCH / SEARCH LIGHT AT AFS MAKARPURA BARODA
2023_MES_617853_1
8829/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹40,000
Yes
2 Dec 2023
8 Sept 2023
13 Oct 2023
8 Sept 2023
6 Oct 2023
22 Sept 2023
9 Sept 2023 - 15 Sept 2023
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as apecified and directed.
M & L for dry Sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed. Note: - Thickness after punning will be measured for payment.
Supply and lay burnt brick sub class `B' old size in trenches adjoining each other width equal to length of brick etc complete all as specified and directed
Returning, filling in including spreading, leveling watering & well ramming in layers not exc. 25cm Soft/loose soil complete all as specified and directed
Removal of excavated material at a distance not exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point for Soft / loose soil complete all as specified and directed
Laying only burnt bricks (old size) retrieved from item No.1.00 here-in-before laid in trenches as cable protection complete all as specified and directed
Labour only for boring under road/drain by manual method for inserting the light grade pipe GI tubing up to 50 mm dia for cable protection complete all as specified and directed
M & L for Road /floor cutting for laying of GI pipe in trenches in road cross / floors and repairing the disturb surface by using PCC 1:2:4 mix, type B1 for protection of cable complete all as specified and directed Note : GI pipe shall be measured and paid seprately
Supply and installation of steel tubular swaged pole complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type confirming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concret in internal surfaces of pole including providing 5Nos synthetic enemelled paint bends (in skyblue and white coloure) of 30cm each as in repairs for 410 SP-31 (9 mtr long) complete all as specified and directed. Note: Excavation / earth work and PCC work shall be measured and paid separately under respective items of BOQ.
Supply and fixing of Galvanised steel tubes, light grade of following size for cable protection laid in pole coping , on wall/ under the road complete all as specified and directed Note : 1. Cost of Bends under the coping, breaking of existing PCC for laying of pipe are deemed to be included with unit rate of item. 2. Taking down of old GI Pipe of any is deemed to be included in quoted rate
40 mm bore
50 mm bore
Supply and laying in repair XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule
Supply and lay in repairs and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 25 Sqmm 4 Core complete all as specified and directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and lay in repairs and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 35 Sqmm 3.5 Core complete all as specified and directed Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and lay in repairs and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 50 Sqmm 3.5 Core complete all as specified and directed Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and lay in repairs and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 70 Sqmm 3.5 Core complete all as specified and directed Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
Supply and fix in repair 1 Sqmm two single core PVC insulated, PVC sheathed multistranded copper conductor flexible cable 1100 volts grade from junction box to street light fitting complete all as specified and directed
Taking down PVC insulated, unsheathed multistranded copper conductor flexible cable of size 1.5 Sqmm and 2.5 Sqmm, 1100 volts grade from junction box after disconnecting from MCB in PVC Junction box and opening the connections from top of the street light fitting from the pole 09/11 mtr hight and from existing building security lights complete all as specified and directed
Material & Labour for opening the existing cable connections from existing junction boxes of street light poles, post top lanterns and building security lights and refixing the same with newly fitted lugs of appropriate size 10, 16, 25, 35, 50, 70 and 95 as the case may be, by opening the existing loop of cable in the roots of street light pole and making the connections new by peeling the insulation with strapper, making proper connections of cable in bus bar of junction box by fixing the new Nut bolts/studs and making flexible wire connection in MCB, MCB should be fixed properly also the junction box covers should be closed in proper manner and fixing the junction boxes on the clamp on the pole by bolts complete all as specifeid and directed Note:- Necessary excavation work for opening the loop and return filling of the excavated material, lugs of appropriate sizes, Nut bolts and tape roll box and other associated works will be the part of this Job and no additional cost will be paid to the contractor, Cost of MCB, New Junction boxes, clamps, flexible wire if replaced with new one will be paid under respective item of BOQ.
Material & Labour for load balancing at different control panels of street lights at different locations of Makarpura by proper R,Y, B phase sequencing of the street light fittings so that the load in each phase will be equal and unbalance of load in any of the phase be sorted out. the test report before and after balancing will be submitted by the contractor complete all as specified and directed
Taking down of old existing MS Clamp and Supply and fix new MS clamps of size 40 x 5 mm in cross sectional area and upto 500 mm in length suitable for fixing the PVC Junction boxes to the street light poles and boundary walls as the case may be, including making necessary holes and nuts/bolts required for fixing the junction box to the poles either steel tubular or PCC Pole or at the boundary wall for post top lights complete all as specified and directed
Material & Labour for preparation of old painted surface of steel tubular pole (9/11 meter long above coping) and applying two coats of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one coat of synthetic enamel paint , rewriting pole No by painter with synthetic enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed.
Supply and fix in repair to timer switch Digital type 24 hours with 15 min and 30 min, 40 Amp current rating 230 volts AC 50 Hzs suitable for street lights and all as specified and directed. Make : Legrand Cat Part No.CX3 CT 230V 2NO 40 A or equivalent in Phillips/Crompton
Supply and fixing 3 pole power contactor type ML 3 AC 3 rating(100A) Aux Contactors 2NO+2NC Cat No SS90721 of Make- L&T compatible with digital timer of suitable capacity or equivalent of Legrand / Crompton / Bajaj complete all as specified and directed
Supply and fixing MCB’s double pole with neutral, 6 to 32 Amps, 250 volts with ‘C’ curve, fixed in existing PVC box including connecting complete all as specified and directed
Supply and fixing MCB’s DB TPN, 32 to 100 Amps, 250 volts with ‘C’ curve, fixed in existing PVC box including connecting complete all as specified and directed
Disconnecting the existing unserviceable PVC box and Supply and fix PVC box of outside size 350mm x 250mm x 150mm and inside size 300mm x 200mm x 105 mm including 4 Nos of bus bar strip of aluminium of size 25x4 mm suitable for 440 volts of suitable amps rating including 1 No MCB SPN ,6 to 32 Amps, 250 volts with 'C' curve, to be fixed on pole with clamp complete all as specified and directed
Repair/servicing including replacement of unserviceable motor operated swivelling type high intensive search cum flood light control gear motor and fiber based rotating disc of revolving mechanism motor,inbuilt speed reduction unit (5-10 RPM) speed control unit with reverse foreward facility and all motor overhauling, servicing, replacement of minor spare parts complete all as specified and directed
Comprehensive maintenance of street light fitting comprising of LED Street light fitting/ HPSV/MH/ lamp fittings of any make any model fitted on the pole at any height with any type of fixing arrangement by replacing the drivers, surge protection device, ignitor ,ballasts capacitor, control wiring copper wire and lugs all as directed by Engineer in charge.(Comprehensive maintenanace also includes taking down street light fitting of any capacity from any height from the pole and increase or decrease the height of the fixing arrangement by removing the bent pipe and clamps and refixing it to the proper height and removing all the hanging wires,cables,PVC pipes,old rusted clamps,hanging aluminium wires,hanging grasses etc and tightening of all nuts,bolts,clamps and fixing of the street light at proper direction to the satisfaction of Engineer in charge.) Spares under Comprehensive Maint shall be measured and paid separately under respective item of BOQ complete all as specified and directed Note:- (i) T&P including ladder for repair works shall be arranged by the contractor at his own cost. (ii)Repair team for the street lights shall be available all the time to carry out maintanance works.
Dismantling and taking down unserviceable PVC Junction boxes of any size, any description from 09/11 metre high steel tubular or PCC electric pole complete all as specified and directed
Supply & fix in repair LED post top lanterns of 40 Watt rated power and rated CCT 3000k, IP65 aesthatically designed spun Al spigot for mounting LED Driver and spun aluminium canopy which is painted white inside. Epoxy powder coated matt black finish after phosphochromate treatment, weather proof construction having robust design delivers to meet the landscaping needs, Luminaire type, Opaline Model No. CELESTA BGCL 40 W LED, product code- 111538, Make- Bajaj, C&S or equivalent in Orient suitabkle to be fixed over galvanised pole of daimeter upto 50 mm, complete all as specified and directed.
Supply & fix in repair LED post top lanterns of 25 Watt rated power and rated CCT 3000K, IP65 aesthatically designed spun Al spigot for mounting LED Driver and spun aluminium canopy which is painted white inside. Epoxy powder coated matt black finish after phosphochromate treatment, weather proof construction having robust design delivers to meet the landscaping needs , Luminaire type, Opaline Model No. BGCTN 25 W WH LED of Bajaj or equivalent in Oreint, Bajaj, C&S or fixed over galvanised pole of daimeter upto 50mm complete all as specified and directed.
Supply and fix in repair 200 Watt LED flood light with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed Make :Bajaj, Amaze Code 169929 or equivalent of, Philips/Wipro or equivelent approved by GE
Supply and fix 100 Watt SMD LED flood light with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed Make :Bajaj (Product code- BJFL 100),Philips, C&S, Crompton Greaves, Oient or equivelent approved by GE
Supply and fix in repair LED street light fitting of 70 Watt LED IP-66, sealed optic luminaire with housing made of die cast aluminium with smooth finish powder coated for better environmental protection complete all as specified below:- (i) The fixture shall be designed so as to average lumen maintenance of at least 70% at the end of 70000 hours. (ii) The luminaire should be operable with auto adjustable 120-240 volt supply using the same driver. Ambient temperature at LED should not be more that 70 degree centigrade. (iii) Power factor of the electronic driver should be at least 0.90 abd efficiency of the luminaire to be more than 85%. (iv) The fixture should be dark sky complaint. The fixture should use aluminium, MCPCB printed circuit boards for better thermal management. (v) The luminaire should throw the perfect amount of uniform light with exactly the desired intensity, and best pole spacing , along with better light control.
(vi) The luminaire shall employ indivdual optical lens for the each of the LED's to ensure better uniformity of light distribution. (vii) The fixute should be vibration resistance, if the fixture is also to be used in vibration prone areas like flyovers/bridges. (viii) Heat dissipation should be managed through a built in external heat sink. (ix) Colour rendering index of minimum 65 with color temprature of 4000K. Make : Phillips luxeon or equivalent of Wipro/Havells/Crompton Graves
S&F in repairs Decorative LED Bollard light with opel diffuser & aluminium reflector of 6 watt with all accessories prewired fixed with PCC with nut/Bolt on exising Location complete all as specified and directed. Make:-Cat Part No.GRUS-M 6W LED, LTGLCGM6WLED Make: Bajaj/C&S/HAVELLS/PHILIPS/CG
S&F in replacement LED 12 V, 3X3W colourful water proof underwater submersible Fountain lights in RGB Combination of colours, IP 68 complete all as specified and directed. Make:- Cat Part No.MJJC-UWL3X3W-12V LED Fountain Lights, with Automatic Controller System of 9 W 3 LED BIG / Havells / Bajaj/ Philips/ CG/ makes specified in Appendix-B of PS.
S&F in repairs wire mesh net suitable for bollard light fitting of size 0.4m x 0.4m x 0.65m and all the four corner and top bottom angle iron framing of size 15x15x3mm and wire mesh net wire size 1.4mm dia and wire mesh square gap 20mm with four no ring of size 10mm dia and thickness 3.0mm and made 5mm hole for inserting the stud size 5 cm long and 4 mm thick with suitable size bolt also welded in the bottom outer side for holding the casing including PCC 1:2:4 of 20 mm aggregate of size with one coat of red oxide primer and two coats blue colour synthatic enamel paint complete all as specified and directed.
Supply only reflector for existing LED fitting suitable 90/70 watt, Make Bajaj or equivalent in havells or Orient suitable for existing LED Street lights complete all as specified and directed
Supply only driver of LED light suitable for existing 70 watt street light fitting complete all as specified and directed
M & L for repairing the Existing LED light 70 watt by taking down the unserviceable LED light fitting from the pole and repairing/replacing the unserviceable parts like LED Bulb driver, internal wiring etc and refitting the same with all connection after making serviceable complete all as specified and directed (Note:- LED Drivers shall be measured and paid separately)
Material & Labour for earthing complete in repairs with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to GI strip of size 25x4 by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit with RCC pit cover charcoal salt, funnel complete all as shown in the electrical plate No 3 of SSR part – I including necessary testing complete all as specified and directed. Note: In case satisfactory result not achieved all earthing work shall be redone by the contractor without any extra cost to the Government.
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB triple pole with neutral, 100 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
Disconnecting the existing Unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB trple pole with neutral, 63 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed
S&F in repair digital voltmeter 0-500 volts of size 96x96mm complete all as specified and directed b
S&F in repair digital Ampere meter 0-500 volts of size 96x96mm complete all as specified and directed
Supply and fix in repair ballast of 400 watt cap MH complete all as specified and directed
Supply and fix in repair ballast of 250 watt cap MH complete all as specified and directed
Supply and fix in repair HPSV Bulb of 400 watt cap complete all as specified and directed
Supply and fix in repair HPSV Bulb of 250 watt cap complete all as specified and directed
Supply and fix in repair igniter of cap upto 250 Watt MH complete all as specified and directed
Supply and fix in repair Isolator 4 pole 63 Amps 415 volts 50 Hz complete all as specified and directed
Supply and fix in repair Isolator 4 pole 100 Amps 415 volts 50 Hz complete all as specified and directed
Comprehensive maintenance of LED Solar Street light fitting of any make any model fitted on the pole at any height with any type of fixing arrangement by checking all connections, replacing the drivers/ Controller, surge protection device, control wiring copper wire and lugs, battery, solar PV modules all as directed by Engineer in charge.(Comprehensive maintenanace also includes taking down street light fitting of any capacity from any height from the pole and increase or decrease the height of the fixing arrangement by removing the bent pipe and clamps and refixing it to the proper height and removing all the hanging wires, cables, PVC pipes, old rusted clamps, hanging aluminium wires, hanging grasses etc and tightening of all nuts, bolts, clamps and fixing of the street light at proper direction to the satisfaction of Engineer in charge) Spares under Comprehensive Maint should be measured and paid Seprately complete all as specified and directed
M& L for 100 AH battery for solar light fix on pole with fixing arrangement complete all as specified and directed.
M& L for controller for existing Solar LED light complete all as specified and directed
M & L for LED light 15/10 watt for solar light including wiring complete all as specified and directed
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed one twin core cable flat or circular size 4 sqmm complete all as specified and directed
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed one twin core cable flat or circular size 6 sqmm complete all as specified and directed
Dismentling and taking out old unserviceable search lights and supply and fixing of Hi-intensity, long beam, LED search light 300W multi circuit SMD, focus range 800Mtr, CCT 5500K LM6 body dia >440mm, operating voltage :90V-300V,50Hz PF>.95,THD 70 Optics used-PMMMA/PC lens narrow beam 7 degree average lux level>9000 with circuit of approx, 1Mtr toughened with silicon gasket, over/under volt and short circuit protection confirmating to LM79, LM 80, IK07, IP66, Lux Cert, Type tested IS 10322, IS 15885 and B.I.S. suitable to installed on existing rotating disc of revolving Mechanism of Kaline complete all as specified and directed.
MADHAV ENTERPRISE
Gayatri Associates
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .