D.G.(E)
Office of the D.G.(E) LIGHTING DEPARTMENT Kolkata Municipal Corporation 15n Nellie Sengupta Sarani Kolkata-700 087 West Bengal
SUPPLY AND LAYING OF ELECTRICAL CABLES GHAT FOR PROPER FUNCTIONING OF APC DEVICES TO REDUCE AIR POLLUTION AT NEW COMPLEX OF NIMTALA BURNING
2026_KMC_987016_1
KMC/NBG/LTG/CRM/e-01(i)/25-26
Open Tender
Electrical Work/ Equipment
Item Rate
15 days
Nimtala Burning Ghat
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹20,000
13 Jan 2026
13 Jan 2026
28 Jan 2026
13 Jan 2026
27 Jan 2026
13 Jan 2026
TOTAL
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
PWD ELECTRICAL SCHEDULE 2017Laying on Wall / surface with Saddles / clamps.(b)Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting
PWD.BLDG SCHEDULE_W EF 01.11.2017 15-1(C). A 7(a) BUILDING WORKS ( C ) Brickworks,Concrete Works etc A. BRICK WORKS 7. Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth
PWD.BLDG SCHEDULE_W EF 01.11.2017 189-1.I.A.1.ii(a) SECTION 1. ------------BUILDING WORKS (I) PLASTERING, POINTING ETC. A. ORIGINAL WORKS 1.Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar (a) 20 mm thick plaster
PWD ELECTRICAL SCHEDULE 2017 Laying through Masonry Trench.(a)Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand
PWD ELECTRICAL SCHEDULE 2017 Laying on Cable Tray.Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.iiFrom 70sqmm to 150sqmm.
PWD ELECTRICAL SCHEDULE 2017 A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 64. 16SWG MS Box (400X250X65mm) 16"x10"x2.5"
PWD ELECTRICAL SCHEDULE 2017 Finishing cable ends.(b)Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.3... core 35 sqmm cable
PWD ELECTRICAL SCHEDULE 2017 Finishing cable ends.(b)Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.4 core10 sqmm cable
PWD ELECTRICAL SCHEDULE 2017 Finishing cable ends.(b)Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.3...core 95 sqmm cable
PWD ELECTRICAL SCHEDULE 2017 Compression Glands.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring FOR dust & moisture(proof entry of XLPE/PVC armoured cables as below: FOR 3... core.iiupto 35 sqmm
PWD ELECTRICAL SCHEDULE 2017 Compression Glands.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring FOR dust & moisture(proof entry of XLPE/PVC armoured cables as below : FOR 4 core.(iv)upto 16 sqmm
PWD ELECTRICAL SCHEDULE 2017 Compression Glands.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring FOR dust & moisture(proof entry of XLPE/PVC armoured cables as below : FOR 4 core upto 95 sqmm
PWD.BLDG SCHEDULE_W EF 01.11.2017 99-1(F) A. 1 (I) BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS, GATES ETC. A. ORIGINAL WORKS 1. M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. I) For structural members of specified sections weighing less than 22.5 Kg./m
PWD ELECTRICAL SCHEDULE 2017 Fan : Supply & Fixing of per FORated GI cable tray with per FORation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support 200x50x1.25mm (18SWG)
SUPPLY OF XLPE INSULATED ALUMINIUM CONDUCTOR ARMOURED CABLES OF 1.1KV GRADE-25SQMM 4CORE
SUPPLY OF XLPE INSULATED ALUMINIUM CONDUCTOR ARMOURED CABLES OF 1.1KV GRADE-16SQMM 4CORE
SUPPLY OF XLPE INSULATED ALUMINIUM CONDUCTOR ARMOURED CABLES OF 1.1KV GRADE-95SQMM 4CORE
SUPPLY,INSTALLATION OF BARE COPPER WIRE(8SWG) FROM CABLE END BOX TO MOTOR TERMINAL OF BLOWERS, PUMP-MOTOR SETS ETC
PWD ELECTRICAL SCHEDULE 2017 Laying on Wall / surface with Saddles / clamps.(e)Laying of cable above 3... core 90 sqmm and upto 3... core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (HOT Dip) Wire, making hole etc. as necy., mending good damages and painting
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.35 MB
form.pdf
Tender Documents • 0.92 MB
Drawing.pdf
Additional Documents • 0.04 MB
BOQ_2410099.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .