Executive Engineer,PWD
O/o The Executive Engineer Murshidabad Electrical Division P.W.Dte. 184, C.R.Das Road, Berhampore, Murshidabad, PIN-742101
Repair and Renovation of Electrical work at Digital X ray room Anupnagar Hospital.
2026_WBPWD_1004581_1
WBPWD/EE/MsdED/56/e-T of 25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
Murshidabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹9,058
13 Mar 2026
11 Feb 2026
23 Feb 2026
11 Feb 2026
20 Feb 2026
13 Feb 2026
SUB-HEAD -1-DISTRIBUTION WIRING Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 8 Mtr
Average run 10 Mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
On Board
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
19 mm dia 3 mm thick polythene pipe without earth continuity wire
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [for SPNDB to (6+6A)plug]
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [for SPNDB to Computer points & , 16 A plug]
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [for TPNDB to SPNDB]
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC[for TPNDB to AC]
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [from VTPNDB to TPNDB & X-ray machine starter]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes as per GS.
SUB-HEAD -2-PLUGS & SOCKETS S&F 240V, 2 nos. 6A, 3 pin Modular type plug socket (Brand approved by EIC) with 2 nos. 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [6A+6A Combo Baord Plug].As per direction of EIC.
Supply & Fixing 240 V, 16A, 3 pin & 240 V, 6A, 5 pin Modular Modular type plug socket (Brand approved by EIC) with 16A & 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. As per direction of EIC.[Anx-89.96,101,102,103,104]
S&F 240V, 3nos. 6 Amp, 3 pin Modular type plug socket with 3nos. 6A Modular type switch, 1no. 16A 3pin Modular type socket & switch, 1no.C16 SP type modular MCB & 1no. indicator (Brand approved by EIC) without plug top on 18 Module GI Modular type switch board 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Computer Plug]. As per direction of EIC.
SUB-HEAD -3-BDB,PDB,VTPN ETC Supplying and fixing 6 way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, concelled in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [415V, 160A, 35 kA, FP MCCB with adjustable thermal & fixed magnetic setting as incomer - 1 no. & 415V, 63A, 10 kA C-curve, TP MCB as outgoing - 6 nos.] (Make - L&T/Legrand/ Siemens).
Supplying and fixing double door sheet steel(16SWG), powder coated cable end box for vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the amages to original finish with nuts bolts etc incl. provision for earthing attachment.4 Way
Supply & fixing 415 Volt 16 - 32 Amp per way 6way HTPN MCB DB with SS enclosure double door with IP-42/43 protection with 63 Amp. 4P MCB Isolater as incomer and 18 nos. 6-32 A SP MCB ('C' Curve, 10 KA) as outgoing concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size Cu. wire and neutral link & provision for earthing attachment as to G.S. (Make - L&T/Legrand/ Siemens).
Supply & Fixing 2+8 way, 250V, 6-10A per way, SPN MCB DB with SS enclouser(A9HSND06) double door with IP- 42/43 protection with 40A DP MCB Isolator as incomer and 8 nos 6-32 A SPMCB ('C' Curve, 10KA) as outgoing concealed in wall after cutting the wall and mending the good damages to original finish incl. inter connection with suitable size Cu wire and neutral link & provision for earthing attachment as to G.S. (Make - L&T/Legrand/ Siemens).
Supply & Fixing EI danger board on wall , 15 cm x 10 cm (6"x4")
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Make- Siemens / L&T / as per direction of EIC] .160 A
Supplying & Fixing Industrial Plug & Socket board with 415 V, 63A,TPN & Earth Metal Industrial Plug socket & 63A Industrial top incl. S&F 63 A TPN MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. (Havells; Cat :- DHDPBENO63)
SUB-HEAD 4-- SUPPLY & LAYING OF CABLES Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make RR KKabel/Gloster/polycab/KEI/Havells]
4Core 35 Sq. mm ( from Pannel to VTPN)
Laying of cable From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. after cutting floor/pavement/wall/ and making holes incl., embedding the cable an average depth as below and mending good the damages to original finish incl. removing the rubbish
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire
Up to 50 sqmm
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable 4 Core S&F solderless socet (Dowelmake), tapes anti corrasive paste & jointing materials.
4Core 35 Sq. mm
SUB-HEAD 5 -SUPPLY & FIXING OF LIGHT FITTINGS Supply & Delivery of 4 feet single commercial LED type light fittings complete with all accessories similar to Philips make cat No. TMC 502 P2 x T - LED 22 W with Master LED Tube lamp of 1200 mm , 18W 865 T 8I- 2100 ln corresponding to Philips / Wipro. As per direction of EIC.
Supply & Delivery of 4 feet twin commercial LED type fluorescent light fittings complete with all accessories similar to Philips make cat No. TMC 502 P1 x T - LED 22 W P3 241 with Master LED Tube lamp of 1200 mm , 18W 865 T 81- 2100 ln corresponding to Philips / Magic / Crompton/ PWD approved. As per direction of EIC.
Supplying & Fixing angular holder (Anchor) on 3" dia wooden double round block incl. S&F 9 Watt LED lamp (Make Philips / Wipro / Havells / PWD Approved ) as per direction of EIC.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required
SUB-HEAD 6 -- SUPPLY & FIXING OF FANS Supply and delivery of 230V 1200mm sweep 5 star ceiling fan (28Watt or less BLDC fan incl remote, class of insulation -'B', SERVICE VALUE (CMM/W minimum 6.85, R.P.M. 350(min), THD <10%, supplied with remote control or wall mounted speed regulator, P.F. not less than 0.9, bult in 2.5KV SPD with complete accessories[Make: Usha, Crompton, Atomberg ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per direction of EIC as per direction of EIC.
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by after making housing for regulator by cutting bakelite top cover incl. making necy. connections etc. as per G.S. .
SUB-HEAD 7 -- Air Conditioning System SITC of 1.5 Ton SPLIT type room air conditioner machine having the following specification:- (a) Cooling capacity nominal (BTU):18000 (b) Star rating-4 star. (c) Rated voltage—230v +/-5%, Frequency-50Hz. (d) Compressor type-Rotary, Condenser and evaporator- Copper Coil (e) Refrigerant : R32/R410A (f) Mini. Room Discharge Air flow range CFM (780-850). (g) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option (low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl.necry all delivery charges, the Compressor of the AC machines should be warranted for 5 years.(MAKE-O GENERAL,ASGA18BUTA-B (R32)/ Mitsubishi Electric/Daikin) and the Split AC machine should be warranted for 5years
Supply and installation of Copper refrigeration pipe of suitable diameter, insulation of pipe by black kenefoam, tape joiting material, connecting IDU and ODU by 3 core 2.5MM Copper Wire & 20 mm dia Water drain pipe for 1.5/2 Ton split AC machines as par direction of EIC.
i) 5/8" copper pipe.and ii) 1/4" copper pipe.
Charges for scaffolding arrangement incl. lifting of outdoor & indoor units of AC machines.
Supply & charging R-32/R-410 gas for the whole unit of 1.5 Ton/2Ton capacity Split type AC Machine as per direction of EIC by contractors own tools and skilled technicians.
Supplying , fabrication , & fixing 3 Nos. M.S.equal angle - channel of 6 mm thick of size ( 50mm X 50 mm) of 3 m length for making Base Frame for installation of outdoor unit of 1.5/2 ton split AC machine incl. Drilling 2 nos. Holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1: 1 1/2 : 3) etc. fabricated with 2 nos. horizontal angle of 50 mm x 6 mm of 2.5 m and grouting on roof and finished with sand cement . ( Drawing should be approved prior work by EIC).
SUB-HEAD 8 -- EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Soft Soil .
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below With TATA-Medium GI pipe as per GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS. 4 SWG
SSupplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
SUB-HEAD 9 -- MISCELLANEOUS Dismantling the existing damage , defective & non functioning Electrical accessories by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC. and the agency have to submit the dismantled Electrical Installations at theHospital Authority by their own arrangements with full list of items.
S/F DOL type starter Cinsisting of 1 No. 63 A 4Pole Contactor(L&T MCX12 Cat No. CS97014 or equivalent of Siemens), 1 no. 100A capacity 4 way terminal block, 1 no. Auxiliary Contact for ON indication, On Push Switch-1No & OFf Push Switch-1No.,1 No.6A SP MCB for indicating lamp, One no. LED Indicating lamp for ON indication(makeL&T/Legrand), single core PVC insulated 10 sqmm Copper wire for interconnetion(make KEI/Polycab). suitable size Copper socketing. The above items are to be assembled in suitable size 19swg Sheet steel enclosure of size 400x300x150powder coating RAL 7032, the above DOL statret to be fixed on wall with MS clamp (Make :- L&T/Legrand).
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy.connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240V 25A 3 Pin type plug top with indicator ( Brand approved by EIC) and necessary connection
Supply and Fixing Timer DB(Water Proof) concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and febricated with following items as per instructions of EIC i) 240 V, 6-32 A SPMCB of breaking capacity 10KA & ''C'' Charecteristic -- 02 no ii) 240V 40 A DP MCB Isolator on din rail --- 01 No. iii) 240V , 3P,Contactor cat no-MNX-25-L&T (2024) (rating above 25 Amp) with accessories ----- 01 no,Aux Contact MNX-25-01,L&T (2024) iv) Analog Timer Switch L&T (J648B1) --- 01no v) Toggle switch for manual/auto operation --- 01no. vi) Double door 2+12 Way SPNDB ---- 1No vii) Necessary connection by copper wire 2X4 + 1X2.5 Sqmm wire. viii) indicating lamp-2 [Make = ,L&T/Legrand]
Total Rs.
Add GST 18%
Total
Add LWC 1%
Total Rs.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.37 MB
Tendernotice_2.pdf
PDF • 0.55 MB
BOQ_2463236.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid