Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.0 LAdmitted-Finance | ₹70.0 L | L1 | Admitted-Finance |
| 2 | L2₹72.8 LAdmitted-Finance | ₹72.8 L | L2 | Admitted-Finance |
| 3 | L3₹78.0 LAdmitted-Finance | ₹78.0 L | L3 | Admitted-Finance |
| 4 | L4₹80.6 LAdmitted-Finance | ₹80.6 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Qualified as per NIT. |
| Sl No | Description | Qty | Unit | reflection L2 | MEPF INFRA L4 | Vinay Technical Works L1 | V B PRASADA REDDY L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | False ceiling: Providing and Fixing in position Suspended false ceiling system using 600 x 600mm Calcium Silicate Ceiling tiles (AEROLITE
ceiling systems - Cosmos / Spintone / Hexa / Quadra Models) Tiles having 15mm densified edges and 100% humidity resistance, incombustible as per BS476 part IV with thermal conductivity of 0.043 w/m KC and approvred surface design and edge profile (TEGULAR/ SPINTONE) placed in a suspended grid of size of 600 x 600mm made of hot-dipped G.I steel sections having an exposed surface capping of pre-finished baked polyester painted coil wherein the main tee of size 24mm x 38mm x 0.33mm shall be suspended at 1200 mm centres along the length of ceiling with 4mm dia G.I wire with necessary level adjusters and cross tees of size 24 x 28 x 0.33mm x 1200 mm shall be inserted in to slots between the main tees at 600mm centres and thereafter in direction vertical to the longer tees, cross tees of size 24 x 28 x 0.33mm x 600mm shall be inserted to form a grid size of 600 x 600 mm resting on the perifery walls on wall angles of size 20mm x 20mm x 3000 mm x 0.40 mm thickness.
The rate shall include providing necessary openings for light fixtures, diffusers, trap doors etc to be made as per layout drawings. The work shall be carried out as per directions of Engineer-in-charge. The main tees to be suspended from the ceiling/ soffit with the help of matal dash fastners of 6mmx50mm, soffit clits of 25mmx35xxx1.60mm and 4mm dia G.I wire with galvanised spring steel levelling clips. the entire grid system shall be designed to bear a distributed load of minimum 15 kg/Sq.m
(Only calcium silicate false ceiling area will be measured for the purpose of payment). | 650 | SqM | 5,900 ₹38,35,000 | 2,800 ₹18,20,000 | 1,550 ₹10,07,500 | 2,000 ₹13,00,000 |
| 2.00 | False ceiling: Providing and fixing in position suspended seamless false ceiling system using 12.50 mm thick moisture resistant plain gypsum
board ( GYPROC.MR of M/s .Saint Gobain make) suspended ceiling, which includes Gypsteel ULTRA™ CRP surface ribbed perimeter channels (having one flange of 20mm and another flange of 30mm and a web of 27mm) along the perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending Gypsteel ULTRA™ CRP surface ribbed intermediate channels of size 45mm (with two flanges of 15mm each) from the soffit at 1220mm centres with Gypsteel ULTRA™ CRP surface ribbed ceiling angle of width 25mmx10mm fixed to soffit with GI cleat and steel expansion fasteners (Mfg by Ms Saint Gobain Gyproc)
Gypsteel ULTRA™ CRP surface ribbed Ceiling section of having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the Gypsteel ULTRA™ intermediate channel with the help of connecting clip and in direction perpendicular to the Gypsteel intermediate™ channel at 457.5mm centres. Single layer of 12.5mm tapered edge Gyproc® MR (conforming to BS 1230 part 1) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc jointing compound, Gyproc joint paper tape and two coats of drywall top coat (as per recommended practices of M/s Saint- Gobain Gyproc India) | 155 | SqM | 3,300 ₹5,11,500 | 2,138 ₹3,31,390 | 1,300 ₹2,01,500 | 2,350 ₹3,64,250 |
| 3.00 | False flooring:
Providing , supplying and fixing False Flooring of height up to 400mm height in 600 x 600 mm panels fabricated out of CRCA sheets infilled with cementitious fillers and top surface with 1.50 mm Anti Static lamination of 1.50 mm thickness from the Specilized approved manufacturers of capacity of 1350 Kgs/sqm UDL and 450 Kgs Point Load with required supports at floor and walls complete as per drawings and as directed at site .(False flooring system to be got approved by the Engineer in charge before procurement) | 575 | SqM | 3,000 ₹17,25,000 | 5,853 ₹33,65,475 | 5,600 ₹32,20,000 | 4,450 ₹25,58,750 |
| 4.00 | False flooring:
Providing , supplying and fixing False Flooring of height up to 1000mm height in 600 x 600 mm panels fabricated out of CRCA sheets infilled with cementitious fillers and top surface with 1.50 mm Anti Static lamination of 1.50 mm thickness from the Specilized approved manufacturers of capacity of 1350 Kgs/sqm UDL and 450 Kgs Point Load with required supports at floor and walls complete as per drawings and as directed at site .(False flooring system to be got approved by the Engineer in charge before procurement) | 190 | SqM | 3,000 ₹5,70,000 | 6,341 ₹12,04,790 | 6,300 ₹11,97,000 | 6,300 ₹11,97,000 |
| 5.00 | Providing and fixing anodized aluminium work (Anodised Aluminium sections of Minimum anodizing thickness of 15micron) for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as
per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealent etc. (fittings glazing and panelling shall be paid for separately) | 140 | Kg | 700 ₹98,000 | 575 ₹80,500 | 730 ₹1,02,200 | 550 ₹77,000 |
| 6.00 | Providing and fixing glazing in aluminium doors, window, ventilator
shutters and partitions etc with With clear float glass panes of 5.00 mm thickness and PVC / Neoprene gasket etc.complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item) | 16 | SqM | 2,600 ₹41,600 | 1,787 ₹28,592 | 1,150 ₹18,400 | 5,100 ₹81,600 |
| 7.00 | Providing and fixing anodised aluminium tower bolts of size 300 X 12 mm (barrel type) ISI marked of approved make transparent or dyed to requried colour or shade with necessary screws etc.all as per specifications and as per drawings. | 4 | Nos | 300 ₹1,200 | 349 ₹1,396 | 250 ₹1,000 | 1,100 ₹4,400 |
| 8.00 | Providing and fixing 4 Lever Mortice Lock of approved make suitable for aluminium sections | 4 | Nos | 3,000 ₹12,000 | 675 ₹2,700 | 1,000 ₹4,000 | 4,450 ₹17,800 |
| 9.00 | Providing and fixing double action hydraulic floor spring of approved brand and manufacturer (conforming to relevant Indian Standard) for doors including cost of cutting floors as required, embedding in floors and cover plates with M.S pivot and single piece of M.S sheet outer box with slide plate etc. complete as per directions of Engineer-in-charge with brass cover plate | 4 | Nos | 2,000 ₹8,000 | 3,049 ₹12,196 | 6,000 ₹24,000 | 5,900 ₹23,600 |
| 10.00 | Providing, Supplying and fixing 120 Minutes Fire Resistance Gypsum Drywall Partition with overall thickness of approximately 95 to 102 mm thick Gypsteel Ultra stud partition which includes two layers of tapered edge 12.5 mm thick Gyproc Fireline on both sides (conforming to IS:2095 – 1996-Part-I) is screw fixed with drywall screws of 25 mm & 35 mm at 300 mm centres to either side of 70 mm Gypsteel Ultra C stud (0.5 mm thick having one flange of 34 mm and another flange of 36 mm made of GI Steel) placed at 610 mm centre to centre in 72 mm Gypsteel Ultra floor and ceiling channel (0.5 mm thick have equal flanges of 32mm made of GI steel), which is anchored to the floor & true ceiling using suitable anchor fasteners. The boards are to be fixed to the framework with joints staggered to avoid leakage through joints. A Gypsteel fixing channel of 99mm width (0.9 mm thick having two flanges of 9.5 mm each) has to be provided at the horizontal joints of the outer layer of boards screw fixed to the studs using metal to metal flat head screws.
Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc Jointing compound, Gyproc Joint Paper tape and two coats of Drywall Top Coat (as per recommended practices of Saint- Gobain Gyproc India) . The junction of the partition with masonry & all penetration through the partition has to be treated with a intumescent fire sealant of equivalent fire rating. 25mm glasswool slab of density 32Kg/m3 shall be provided in the cavity. | 50 | SqM | 4,500 ₹2,25,000 | 1,956 ₹97,800 | 4,000 ₹2,00,000 | 6,350 ₹3,17,500 |
Tender Value
₹97.1 L
EMD Value
₹1.9 L
Closing Date
22 May 2026, 3:00 pmClosed
Chief Engineer, BARC(V)
BARC main site, Visakhapatnam.
Providing, supplying, and fixing false ceiling and false flooring, and miscellaneous electrical works in TREndS at BARC, near Visakhapatnam, A.P.
2026_BARC_906172_1
BARC-V/ESS-V/2026/05
Open Tender
Civil Works
180 days
BARC main site, Visakhapatnam
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1.9 L
7 Jul 2026
23 Apr 2026
29 May 2026
23 Apr 2026
22 May 2026
8 May 2026
23 Apr 2026 - 7 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | False ceiling: Providing and Fixing in position Suspended false ceiling system using 600 x 600mm Calcium Silicate Ceiling tiles (AEROLITE
ceiling systems - Cosmos / Spintone / Hexa / Quadra Models) Tiles having 15mm densified edges and 100% humidity resistance, incombustible as per BS476 part IV with thermal conductivity of 0.043 w/m KC and approvred surface design and edge profile (TEGULAR/ SPINTONE) placed in a suspended grid of size of 600 x 600mm made of hot-dipped G.I steel sections having an exposed surface capping of pre-finished baked polyester painted coil wherein the main tee of size 24mm x 38mm x 0.33mm shall be suspended at 1200 mm centres along the length of ceiling with 4mm dia G.I wire with necessary level adjusters and cross tees of size 24 x 28 x 0.33mm x 1200 mm shall be inserted in to slots between the main tees at 600mm centres and thereafter in direction vertical to the longer tees, cross tees of size 24 x 28 x 0.33mm x 600mm shall be inserted to form a grid size of 600 x 600 mm resting on the perifery walls on wall angles of size 20mm x 20mm x 3000 mm x 0.40 mm thickness.
The rate shall include providing necessary openings for light fixtures, diffusers, trap doors etc to be made as per layout drawings. The work shall be carried out as per directions of Engineer-in-charge. The main tees to be suspended from the ceiling/ soffit with the help of matal dash fastners of 6mmx50mm, soffit clits of 25mmx35xxx1.60mm and 4mm dia G.I wire with galvanised spring steel levelling clips. the entire grid system shall be designed to bear a distributed load of minimum 15 kg/Sq.m
(Only calcium silicate false ceiling area will be measured for the purpose of payment). | 650 | SqM | - | - |
| 2 | False ceiling: Providing and fixing in position suspended seamless false ceiling system using 12.50 mm thick moisture resistant plain gypsum
board ( GYPROC.MR of M/s .Saint Gobain make) suspended ceiling, which includes Gypsteel ULTRA™ CRP surface ribbed perimeter channels (having one flange of 20mm and another flange of 30mm and a web of 27mm) along the perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending Gypsteel ULTRA™ CRP surface ribbed intermediate channels of size 45mm (with two flanges of 15mm each) from the soffit at 1220mm centres with Gypsteel ULTRA™ CRP surface ribbed ceiling angle of width 25mmx10mm fixed to soffit with GI cleat and steel expansion fasteners (Mfg by Ms Saint Gobain Gyproc)
Gypsteel ULTRA™ CRP surface ribbed Ceiling section of having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the Gypsteel ULTRA™ intermediate channel with the help of connecting clip and in direction perpendicular to the Gypsteel intermediate™ channel at 457.5mm centres. Single layer of 12.5mm tapered edge Gyproc® MR (conforming to BS 1230 part 1) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc jointing compound, Gyproc joint paper tape and two coats of drywall top coat (as per recommended practices of M/s Saint- Gobain Gyproc India) | 155 | SqM | - | - |
| 3 | False flooring:
Providing , supplying and fixing False Flooring of height up to 400mm height in 600 x 600 mm panels fabricated out of CRCA sheets infilled with cementitious fillers and top surface with 1.50 mm Anti Static lamination of 1.50 mm thickness from the Specilized approved manufacturers of capacity of 1350 Kgs/sqm UDL and 450 Kgs Point Load with required supports at floor and walls complete as per drawings and as directed at site .(False flooring system to be got approved by the Engineer in charge before procurement) | 575 | SqM | - | - |
| 4 | False flooring:
Providing , supplying and fixing False Flooring of height up to 1000mm height in 600 x 600 mm panels fabricated out of CRCA sheets infilled with cementitious fillers and top surface with 1.50 mm Anti Static lamination of 1.50 mm thickness from the Specilized approved manufacturers of capacity of 1350 Kgs/sqm UDL and 450 Kgs Point Load with required supports at floor and walls complete as per drawings and as directed at site .(False flooring system to be got approved by the Engineer in charge before procurement) | 190 | SqM | - | - |
| 5 | Providing and fixing anodized aluminium work (Anodised Aluminium sections of Minimum anodizing thickness of 15micron) for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as
per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealent etc. (fittings glazing and panelling shall be paid for separately) | 140 | Kg | - | - |
| 6 | Providing and fixing glazing in aluminium doors, window, ventilator
shutters and partitions etc with With clear float glass panes of 5.00 mm thickness and PVC / Neoprene gasket etc.complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item) | 16 | SqM | - | - |
| 7 | Providing and fixing anodised aluminium tower bolts of size 300 X 12 mm (barrel type) ISI marked of approved make transparent or dyed to requried colour or shade with necessary screws etc.all as per specifications and as per drawings. | 4 | Nos | - | - |
| 8 | Providing and fixing 4 Lever Mortice Lock of approved make suitable for aluminium sections | 4 | Nos | - | - |
| 9 | Providing and fixing double action hydraulic floor spring of approved brand and manufacturer (conforming to relevant Indian Standard) for doors including cost of cutting floors as required, embedding in floors and cover plates with M.S pivot and single piece of M.S sheet outer box with slide plate etc. complete as per directions of Engineer-in-charge with brass cover plate | 4 | Nos | - | - |
| 10 | Providing, Supplying and fixing 120 Minutes Fire Resistance Gypsum Drywall Partition with overall thickness of approximately 95 to 102 mm thick Gypsteel Ultra stud partition which includes two layers of tapered edge 12.5 mm thick Gyproc Fireline on both sides (conforming to IS:2095 – 1996-Part-I) is screw fixed with drywall screws of 25 mm & 35 mm at 300 mm centres to either side of 70 mm Gypsteel Ultra C stud (0.5 mm thick having one flange of 34 mm and another flange of 36 mm made of GI Steel) placed at 610 mm centre to centre in 72 mm Gypsteel Ultra floor and ceiling channel (0.5 mm thick have equal flanges of 32mm made of GI steel), which is anchored to the floor & true ceiling using suitable anchor fasteners. The boards are to be fixed to the framework with joints staggered to avoid leakage through joints. A Gypsteel fixing channel of 99mm width (0.9 mm thick having two flanges of 9.5 mm each) has to be provided at the horizontal joints of the outer layer of boards screw fixed to the studs using metal to metal flat head screws.
Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc Jointing compound, Gyproc Joint Paper tape and two coats of Drywall Top Coat (as per recommended practices of Saint- Gobain Gyproc India) . The junction of the partition with masonry & all penetration through the partition has to be treated with a intumescent fire sealant of equivalent fire rating. 25mm glasswool slab of density 32Kg/m3 shall be provided in the cavity. | 50 | SqM | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.79 MB
LetterTransmittal052026.pdf
Tender Documents • 0.61 MB
FormofAgreement052026.pdf
Tender Documents • 0.40 MB
Tenderdocument052026.pdf
Tender Documents • 1.99 MB
FormsAtoH052026.xls
Tender Documents • 0.06 MB
BOQ_952479.xls
BOQ • 0.30 MB
corrigendum1052026.pdf
PDF • 0.41 MB
Download all tender documents and submit your bid