Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC | ₹3.5 L | L1 | Accepted-AOC work allotted |
| 2 | L2₹3.6 L+₹18,031 (5.21%)Rejected-Finance | ₹3.6 L+₹18,031 (5.21%) | L2 | Rejected-Finance L2 |
Tender Value
₹3.1 L
EMD Value
₹6,300
Closing Date
1 Jun 2022, 2:00 pmClosed
Executive Engineer
Executive Engineer, Elect. Division PWD BandR Br., Karnal (0184-2265696)
Providing Special repair to EI in State Disease Diagnostic Laboratory AHandD, Mehlana Road, Sonipat. (Pdg. EI only).
2022_HRY_222352_1
Laboratory Mehlana Sonipat
Open Tender
Electrical Works
Works
60 days
Sonipat
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹6,300
30 Sept 2022
19 May 2022
1 Jun 2022
19 May 2022
1 Jun 2022
19 May 2022
Amount
COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 23.1.1.2 Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B
23.1.5.2 Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group B
Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 23.1.6.1 1 run of Size 1.50 Sqmm(1/1.40mm)
23.1.6.2 1 run of Size 2.50 Sqmm(1.1.80mm)
23.1.6.3 1 run of Size 4 Sqmm(1/2.24mm)
23.5.1.2 Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. Group B
23.5.4.2 Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required Group B
23.5.5.2 Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required Group B
23.5.6.1 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)
23.5.6.2 1 run of Size 2.50 Sqmm(1.1.80mm)
23.5.6.3 1 run of Size 4 Sqmm(1/2.24mm)
23.6.6.1 Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia.
23.7.6.2 Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
23.8.1.6 Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type
23.8.1.13 Socket size rotary step type Electronic regulator for A.C. ceiling fan
23.8.10 Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 4 Modules
23.8.11.3 Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch
23.8.11.5 15 amp 6 pin Socket
23.8.11.10 Blanking plate
23.9 Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.
23.11 Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless stell wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required
23.12 Providing and fixing outdoor duty Ply of 8 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required
23.20 Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required.
23.21 Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required
23.22.1.9 Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp
23.22.2.1 MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP
23.22.3.3 Supply and erection of sheet steel enclosures 1pole/ 2 pole/4 pole including providing SP/DP/TP/FP MCB on wall/on existing pedestal complete with necessary connections etc, :- TPN enclosure suitable for TP,TPN or FPMCB
23.22.4.7 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)
23.22.5.1 Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
23.22.5.8 40 amp to 63 amp. MCB's FOUR POLE
23.24.1 Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.
23.25.2.1 Dismantling old wiring points ( Recess wiring or partly recess partly surface system , recess Conduit and box not to be dismantled ) including necessary repairs to wall etc. Light, fan or call bell Point including circuit/sub main wiring
23.25.2.2 Wall socket point including circuit/submain wiring
24.1.1 Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
24.1.2 Extra for using salt and char coal/coke for pipe earth electrode as required.
24.1.3 Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
24.1.4 Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
24.1.5 Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
24.1.7 Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
24.1.8 Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
24.1.9 Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
24.1.10 Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
Note:additional cable in same trench : 50% of Main cable cost 24.2.7.2 Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core
24.2.7.3 25 sqmm to 50 sqmm Cable 2 to 4 Core
24.2.8.3 Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer- in-charge of the work. 10 sqmm
24.4.16 Supply and erection of weather proof M.S. box size 20 cm * 15 cm * 10 cm covered with 3.00 mm thick M.S. sheet hinged cover, locking arrangement, housed in wall, including the cost of 1 no. 16 amp. 415 volts SPMCB and 2 no. 63 amp. 415 volts neutral links fixed on hard wood board/ 10 mm Bakelite sheet in the M.S. box including painting and necessary connections.
24.5.2.3 S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
NS items Supply and erection of under ground Aluminum Armoured cable XLPE insulated loose in existing pipe or trenches complete with necessary connection. Make RR / Havells / Polycab 10 sqmm 2 Core
16 sqmm 4 Core
50 sqmm 3.5 Core
G.B. Traders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .