Executive Engineer Panchayat R&B Division Amreli
Construction of New Taluka Panchayat Office Building at Amreli, Ta. &Dist.Amreli
307954
Tender Notice No.1/2026-27, Sr.No.42
Open
Civil Works - Buildings
Works
Amreli
7 documents required · 6 mandatory · 1 optional
₹6,000
Executive Engineer Panchayat R&B Division Amreli
₹4.1 L
22 May 2026
22 May 2026
22 May 2026
29 May 2026
22 May 2026
Name of Work :: Construction of New Taluka Panchayat Office Building at Amreli, Ta. & Dist. : Amreli
Bill of Quantities (BOQ)
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[1] Excavation for foundation upto 1.5 m depth including sorting out 1111.70 Cum 157.16
and stacking of useful materials and disposing off the excavated
stuff upto 50 Meter lead.(B) Dense or Hard Soil
[2] Excavation for foundation for depth from 1.5 m to 3.0 m 292.00 Cum 287.21
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.
(C) Hard Murrum
[3] Excavation for foundation for depth from 1.5 m to 3.0 m 371.00 Cum 300.02
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.
(D) Soft rock not requiring Blasting
[4] Providing and laying cement concrete 1:2:4 (1 Cement : 2 corse 300.55 Cum 3805.29
sand : 4 granded stone aggregate 20mm nominal size) and
curing complete including cost of form work in (a) Foundation and
[5] Providing and laying cement concrete work 1:2:4 (M-15)(1- 72.25 Cum 4189.91
Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm
nominal size) and curing complete excluding cost of formwork and
reinforcement for reinforced concrete work in (B) Slabs,
landing, shelves, Balconis , Lintels, Beams, Girders and Cantilever
upto floor two level.
[6] Applying general insecticide pest control treatment to floors, 610.00 Sqm 39.09
cupboards etc including labour material etc. complete.
Using Heptachloride 20 EC. As Per 6113_pests Consentration
Weight 0.50 percent is recommended one litre chemical
emulsion dillute with 39 liter of water will give. Total dillute
concrentration will be 40 litre inclusive of one litre chemical
emulsion appication 0.5 Litre chemical / Sqm of surface is
recommended as per I.S
[7] Filling available excavated earth (excluding Rock) in trenches, 562.60 Cum 136.92
plinth, sides of foundation etc. in layers not exceeding 20.cm. in
depth consolidating each deposited layer by ramming and
[8] Filling in plinth with sand under floors includingwatering 69.20 Cum 481.80
ramming, consolidating and dressing etc.complete.
[9] Filling in foundation and plinth with murrum or selected soil in 907.95 Cum 301.78
layers of 20cm. thickness including watering, ramming
and consolidating etc. complete.
[10] Brick work using common burnt Clay building bricks having 197.25 Cum 4214.33
crushing strength not less than 35 kg / sq.cm in foundation and
plinth in Cement mortar 1:6 (1 Cement : 6 fine sand) (A)
[11] Providing and laying controlled cement concrete M 250 282.90 Cum 4941.58
and curing complete including the cost of formwork but
excluding the cost of reinforcement for reinforced concrete
work in (A) Foundations, Footing base of columns.
[12] Providing and laying controlled cement concrete M 250 79.25 Cum 7133.40
and curing complete including the cost of formwork but
excluding the cost of reinforcement for reinforced concrete
work in (A) Column from Footing Top to Plinth Beam
[13] Providing and laying controlled cement concrete M-200 45.35 Cum 8583.78
and curing complete including the cost of formwork with
ordinary timber planking so as to give a rough finish incl.
centering shuttering strutting and propping etc.. but
excluding the cost of reinforcement of R.C.C. work in
Columns, Pillars posts and struts for Ground Floor Level.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[14] Providing and laying controlled cement concrete M-200 28.25 Cum 8625.38
and curing complete including the cost of formwork with
ordinary timber planking so as to give a rough finish incl.
centering shuttering strutting and propping etc.. but
excluding the cost of reinforcement of R.C.C. work in
Columns, Pillars posts and struts for First Floor Level.
[15] Providing and laying controlled cement concrete M-200 21.75 Cum 6370.85
and curing complete including the cost of formwork with
ordinary timber planking so as to give a rough finish incl.
centering shuttering strutting and propping etc.. but
excluding the cost of reinforcement of R.C.C. work in
Columns, Pillars posts, beams and struts for Second Floor Level.
[16] Providing and laying controlled cement concrete M-250 110.70 Cum 5932.30
and curing complete including the cost of formwork with
ordinary timber planking so as to give a rough finish incl.
centering shuttering strutting and propping etc..but
excluding the cost of reinforcement for reiforced concrete
work in Beams for Plinth Level Beam
[17] Providing and laying controlled cement concrete M-200 82.15 Cum 6287.66
and curing complete including the cost of formwork with
ordinary timber planking so as to give a rough finish incl.
centering shuttering strutting and propping etc..but
excluding the cost of reinforcement for reiforced concrete
work in Beams for Ground Floor Level Beam
[18] Providing and laying controlled cement concrete M-200 78.00 Cum 6329.26
and curing complete including the cost of formwork with
ordinary timber planking so as to give a rough finish incl.
centering shuttering strutting and propping etc..but
excluding the cost of reinforcement for reiforced concrete
work in Beams for First Floor Slab Level Beam.
[19] Providing and laying controlled cement concrete M.200 and 7.00 Cum 6439.70
curing complete with ordinary timber planking so as to give a
rough finish but excluding the cost of reinforcement for
reinforced concrete work in (C) R.C.C. LINTELS / Sill bends
incl. Finishing smooth with curring of formwork but excl. the
cost of reinforcement.for Ground Floor level.
[20] Providing and laying controlled cement concrete M.200 and 5.25 Cum 6481.29
curing complete with ordinary timber planking so as to give a
rough finish but excluding the cost of reinforcement for
reinforced concrete work in (C) R.C.C. LINTELS / Sill bends
incl. Finishing smooth with curring of formwork but excl. the cost
of reinforcement.for First Floor level.
[21] Providing and laying controlled cement concrete M.200 and 0.50 Cum 6522.88
curing complete with ordinary timber planking so as to give a
rough finish but excluding the cost of reinforcement for
reinforced concrete work in (C) R.C.C. LINTELS / Sill bends
incl. Finishing smooth with curring of formwork but excl. the
cost of reinforcement.for Second Floor level.
[22] Providing & laying controlled cement concrete M-200 and 4.00 Cum 6341.50
curing complete including the cost of formwork with ordinary
timber planking so as to give a rough finish incl. centering
shuttering strutting and propping etc.. But excluding
reinforcement for R.C.C. Chhajjas / shelves for Ground
[23] Providing & laying controlled cement concrete M-200 and 4.00 Cum 6383.10
curing complete including the cost of formwork with ordinary
timber planking so as to give a rough finish incl. centering
shuttering strutting and propping etc.. But excluding
reinforcement for R.C.C. Chhajjas / shelves for First Floor Level.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[24] Providing & laying controlled cement concrete M-200 and 0.50 Cum 6424.70
curing complete including the cost of formwork with ordinary
timber planking so as to give a rough finish incl. centering
shuttering strutting and propping etc.. But excluding
reinforcement for R.C.C. Chhajjas / shelves for Secornd
[25] Providing and laying controlled cement concrete M 200 3.75 Cum 7156.45
and curing complete including the cost of formwork but
excluding the cost of reinforcement for reinforced concrete
work in- Staircases For Ground Floor Level.
[26] Providing and laying controlled cement concrete M 200 3.75 Cum 7198.04
and curing complete including the cost of formwork but
excluding the cost of reinforcement for reinforced concrete
work in- Staircases For First Floor Level.
[27] Providing and laying controlled cement concrete M 200 91.15 Cum 6747.25
and curing complete including the cost of formwork but
excluding reinforcement for reinforced concrete work in-
Slabs For Ground Floor
[28] Providing and laying controlled cement concrete M 200 84.25 Cum 6788.85
and curing complete including the cost of formwork but
excluding reinforcement for reinforced concrete work in-
Slabs For First Floor
[29] Providing and laying controlled cement concrete M 200 5.00 Cum 6830.44
and curing complete including the cost of formwork but
excluding reinforcement for reinforced concrete work in-
Slabs For Second Floor Slab.
[30] Providing and laying cement concrete 1:3:6 (1- Cement: 3- 56.10 Cum 3112.53
Coarsesand :6- Graded brick bat aggregate 40mm normalsize )
and curing complete excluding cost of form work in Rodi
Concrete for terrace level.
[31] Providing cement VATA (10 cmx10 cm size)quartar round in 218.00 Mtr 24.28
cement mortar 1:1 including neat cement finishing watering
[32] Brick work using common burnt Clay building bricks having 207.40 Cum 4496.05
crushing strength not less than 35 kg / sq.cm in super structure
above plinth level up to floor two level in Cement mortar 1:6
(1 Cement : 6 fine sand) (A)conventional - Ground Floor.
[33] Brick work using common burnt Clay building bricks having 109.75 Cum 4538.48
crushing strength not less than 35 kg / sq.cm in super structure
above plinth level up to floor two level in Cement mortar 1:6
(1 Cement : 6 fine ) Conventional - First Floor.
[34] Brick work using common burnt Clay building bricks having 44.00 Cum 4580.91
crushing strength not less than 35 kg / sq.cm in super structure
above plinth level up to floor two level in Cement mortar 1:6
(1 Cement : 6 fine sand) (A)conventional - Second Floor.
[35] Half brick masonary in common burnt Clay building bricks having 237.25 Sqm 750.76
crushing strength not less than 35 kg / sq.cm in in C.M 1:3 (1
Cement : 3 coarse sand) in with 2 nos. of 6 mm dia.mild steel
round bars after every three coarse embedded in cement mortar
in super structure for Ground Floor. (A) Conventional
[36] Half brick masonary in common burnt Clay building bricks having 208.00 Sqm 757.07
crushing strength not less than 35 kg / sq.cm in in C.M 1:3 (1
Cement : 3 coarse sand) in with 2 nos. of 6 mm dia.mild steel
round bars after every three coarse embedded in cement mortar
in super structure for Ground Floor. (A) Conventional
[37] Providing TMT Bar FE 500D reinforcement for R.C.C. work 90843.00 Kg 77.29
including bending, binding and placing in position complete upto
floor two level. For Ground Floor.
[38] Providing TMT Bar FE 500D reinforcement for R.C.C. work 31209.25 Kg 78.34
including bending, binding and placing in position complete upto
floor two level. For First Floor.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[39] Providing and fixing 38mm thick SINGLE SHUTTER HINGED 94.50 Sqm 5539.37
flush door of BWP Grade confirming to IS-710 of approved
quality and design including applying of 1mm thick laminate
sheet of approved quality and design to both both side, all
edges shall be covered with 35x12mm first class teakwood
bedding incl. required steel finished brass hardware like hinges,
handles, mortice locks, door stop, stoppers and lock,etc. of
approved brands and including extruded aluminum colour
anodized "L" section main outer frame size 63.50mm x
38.00mm x 2.50mm (of jindal section 19552 @ Wt.1.1165 kg/mt)
filled with country wood and providing and applying minimum
coats of Melamine Polish and two coats of sealer etc. complete as
directed by Engineer- in-Charge.
[40] Providing and fixing 38mm thick DOUBLE SHUTTER HINGED flush 25.25 Sqm 5621.24
door of BWP Grade confirming to IS-710 of approved quality
and design including applying of 1mm thick laminate sheet
of approved quality and design to both both side, all edges
shall be covered with 35x12mm first class teakwood bedding
incl. Heavy duty Floor SPRING to both shutters and required steel
finished brass hardware like hinges, handles, mortice locks,
door stop, stoppers and lock,etc. of approved brands and
including extruded aluminum colour anodized "L" section
main outer frame size 63.50mm x 38.00mm x 2.50mm (of
jindal section 19552 @ Wt.1.1165 kg/mt) filled with country
wood and providing and applying minimum 3 coats of
Melamine Polish and two coats of sealer etc. complete as directed
by Engineer-in-Charge.
[41] Providing and fixing FRP frame size 100x50 mm and 28mm thick 33.00 Sqm 2377.76
FRP depress panel shutter having extra reinforcement on sides
& edges in Gel coat finish. The core of the shutter & frame is to
be filed up with injected fire retardant grade polyurethene
foam done in situ alongwith embedded wooden pieces for
stiffening & also taking hinges & fintures. The whole FRP frame &
shutter is to be water proof weather proof, termite proof &
resistance to mild acid/alkali. Rates are to be inclusive of S.S
hinges with necessary screws & alluminium fixtures & fastenings &
fastener sleeve.
[42] Providing and fixing THREE track sliding window with Partly 89.75 Sqm 3141.88
Fixed and Partly Sliding Shutters as per drawing provided by
the chief architect : Using standard extruded color anodized
aluminum section equivalent to Jindal series C (20mm) section
numbers: frame bottom track 21651, frame top & sides
shutter top rail 20530, bottom rail 20529, side rails
interlock rails 20531. with 5mm thick transparent tinted float
glass, with rubber gasket, air lock strip and finishing joints with
transparent silicon sealant, with alluminium powder coated
fittings and fixtures.
[43] Providing and fixing TWO track sliding window with Partly fixed 139.55 Sqm 3337.20
and partly Sliding Shutters as per drawing provided by the chief
architect : using standard extruded color anodized aluminum
section equivalent to Jindal series C (20mm) section numbers:
frame bottom track 20695, frame top & sides 20987, shutter top
& bottom rails 20529, side handle 20530, interlock rails
20566. with 5mm thick transparent tinted float glass, with
rubber gasket, air lock strip and finishing joints with
transparent silicon sealant, with alluminium powder coated
fittings and fixtures.
[44] Providing and fixing colour anodised Alluminium sectional 5.75 Sqm 2835.69
ventilators using section 63.50 x 38.10 { Wt 1.50 mm th.} for
mm thick Tinted Glass as per drawing, including fixture and
fastenings and hold fasting with coach bolts etc complete.
{Colour as directed by Engineer in charge
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[45] Providing and fixing in position collapsible steel shutters with 25.25 Sqm 6116.59
vertical channels 20 x 10 x 2mm braced with vertical channels
20 x 5mm size with top and bottom rails of T- iron40 x 40 x
6mm with 38mm dia steel pulleps complete with be ist nuts,
locking arrangement, stoppers handles including applying a
priming coat of red lead paint.
[46] Providing and fixing M.S. Grills for Window Ventilators etc 5887.00 Kg 113.82
openings , made of of 16 mm size Square Bright Bars, framed in
M.S.Flat 75x6 mm size at 10cm. c/c in Horizontal intervals,
welding bright bars in frame incl. cutting, transportion, primer
& oil painting, fixing in position etc. complete.
[47] Providing and fixing AISI 304 Grade stainless steel knock 40.50 Sqm 3190.02
down railing system comprising 50mm dia Railing Pipe fixed on
32 X 32 mm X 16G SS Balustrade of 850mm height placed at
maximum 600mm C/C distance along with Two SS horizontal
mambers of 16mm dia ( 16G) connected at the side of balustor
with SS brackets. The balustrade shall be mounted on floor
with base plate using specially designed anchor fasteners and
concealed by AISI 304 Grade SS base cover cap (Wall thickness of
pipes shall be taken as 1.50mm along with all visible
component developed in high grade SS and wherever required,
joints to be filled with bushings for extra strength).
[48] Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 650.00 Sqm 1074.11
24'' in flooring treads of steps and landing laid on a bed of
12mm thick cement mortar 1:3 (1-cement : 3-coarse sand )
finishing with flush pointing in white cement.
[49] Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' 41.05 Sqm 1144.45
in skrting risers of steps and dedo on 10mm thick cement plaster
1:3 (1-cement : 3-coarse sand) and jointed with white cement
[50] Providing and laying MATT finished GVT Vitrified tiles 8 to 10 324.20 Sqm 1551.52
mm thick , 24'' x 24'' in flooring treads of steps and landing in
two colour pattern laid on a bed of 12mm thick cement mortar
1:3 (1-cement : 3-coarse sand
) finishing with flush pointing in white cement.
[51] Providing and laying MATT finished GVT Vitrified tiles 8 to 10 19.00 Sqm 1605.64
mm thick , 24'' x 24'' in skrting risers of steps and dedo on
10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and
jointed with white cement slurry
[52] Providing and Fixing Sandwich type standing plateform in 8.00 Sqm 5372.55
kitchen using 18mm thick Black GRANITE in top and sides and and
25 to 30 mm thick one side polished Kota Stone in base
including 0.60 mt. wide vertical support of both side polished
Kota Stone and one horizontal shelf 60 cm wide below
plateform as required and including 50mm wide facia patti
in front incl. moulding the exposed edges in half round with
all material, tools and labour etc. complete as directed by
Engineer-In-Charge.
[53] Providing and laying Both side polished Granite Stone 18 3.00 Sqm 2320.28
mm.thick ( all edge machine cut and rounding mirror
polished) of approved shade and colour for CB Shelf / Urinal
Partition purpose including making groove in the wall, moulding
the open edges full round and jointed with grey cement slurry
including rubbing and polishing etc. complete. as required
and directed by Engineer- in-Charge.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[54] Providing and laying 18mm thick Black Granite Stone ( all 248.05 Sqm 3253.31
edge machine cut and rounding mirror polished) of approved
shade in Cills & Jambs incl. applying coarse-cum- fine sand on
the back side of the granite with approved adhesive like Araldite
or eq. to make the surface rough for better bonding with the
wall surface on 10 mm. thick Cement Mortar 1:3 (1-cement,
3-coarse sand) laid and jointed with white cement slurry
including rubbing and polishing complete. use single piece or
two pieces incl. overlapping in up-down position granite stone
for jambs & soffits as required and directed by Engineer- in-
[55] Providing and laying polished Telephone Black Granite Stone 18 98.75 Sqm 2766.44
mm.thick flooring in single piece in treads of steps and riser over
20mm (Average) thick base of cement mortar 1:6 (1-
cement : 6-coarse sand) and jointed with white cement
slurry with matching pigments including rubbing and polishing
and moulding the exposed edges half round etc. complete.
[56] Providing and laying coloured glazed tiles of the size 300 mm x 463.35 Sqm 1488.24
600 mm x 8 mm in skirting and dedo on 10 mm. thick
cement plaster 1:3 (1 cement : 3 coarse sand) & jointed with
white cement slurry.
[57] Providing and laying Mat Finished Ceramic tiles of size 116.00 Sqm 1393.93
600mm x 600mm x 10mm in flooring treads of steps and
landing laid on a bed of 12mm thick cement mortar 1:3 (1-
cement : 3-coarse sand ) finishing with 3mm groove filled
with approved quailty epoxy grout of approved shade as directed
by Engineer-in-charge.
[58] Providing and laying broken china mosaic flooring for 686.70 Sqm 779.70
terrace using 12 mm to 20 mm broken pieces of glazed tiles
to be laid over cement mortar 1:3 to plain or slope and to be
tempered to bring mortar creme out upto surface using
white cement including rounding off junctions and extending
them upto 15 cm along the wall,clearing with water and
oxalic acid etc. as directed.
[59] Providing and fixing pre-cast Rubber Dye / steel Dye inter locking 799.00 Sqm 706.93
concrete block 60mm thick with grade of concrete M300 pnumatic
compressed / vibrated mechanically and as per approved
design Confirming to IS 15658 : 2006 including 35 mm Sand
layer for levelling and filling the joint with sand in proper line and
level as per guidlines of IRC
: SP 63-2018 etc. Complete.
[60] Providing 15 mm thick mala finished cement plaster in 1321.75 Sqm 246.05
single coat on fair side Brick/Concrete walls for interior
plastering upto floor two level finished even and smooth
and finishishing with floating coat of neat cement slurry.(1)
Cement Mortar 1:3 (1 Cement : 3 sand) For GROUND Floor.
[61] Providing 15 mm thick mala finished cement plaster in 981.25 Sqm 274.80
single coat on fair side Brick/Concrete walls for interior
plastering upto floor two level finished even and smooth
and finishishing with floating coat of neat cement slurry.(1)
Cement Mortar 1:3 (1 Cement : 3 sand) for FIRST Floor.
[62] Providing 15 mm thick mala finished cement plaster in 43.75 Sqm 303.56
single coat on fair side Brick/Concrete walls for interior
plastering upto floor two level finished even and smooth
and finishishing with floating coat of neat cement slurry.(1)
Cement Mortar 1:3 (1 Cement : 3 sand) for SECOND Floor.
[63] Providing 10 mm thick mala finished cement plaster in 724.00 Sqm 222.33
single coat on fair side Brick/Concrete walls for interior
plastering on ceiling and soffits of stair upto floor two level
finished even and smooth and finishishing with floating
coat of neat cement slurry.(1) Cement Mortar 1:3 (1
Cement : 3 sand) For GROUND Floor.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[64] Providing 10 mm thick mala finished cement plaster in 697.50 Sqm 272.97
single coat on fair side Brick/Concrete walls for interior
plastering on ceiling and soffits of stair upto floor two level
finished even and smooth and finishishing with floating
coat of neat cement slurry.(1) Cement Mortar 1:3 (1
Cement : 3 sand) upto floor three level i.e. for FIRST Floor.
[65] Providing 10 mm thick mala finished cement plaster in 42.25 Sqm 323.61
single coat on fair side Brick/Concrete walls for interior
plastering on ceiling and soffits of stair upto floor two level
finished even and smooth and finishishing with floating
coat of neat cement slurry.(1) Cement Mortar 1:3 (1
Cement : 3 sand) upto floor three level i.e. for FIRST Floor.
[66] 20 mm thick Double Coat sand faced Gutka cement plaster on 3072.00 Sqm 342.41
wall upto height 10 mts.above ground level consisting of 12 mm
thick backing coat of C.M 1:3 (1 cement : 3 sand )and 8 mm thick
finishing coat of C.M 1 : 1(1 cement : 1 Sand) etc. complete.
[67] Applying two coats of putty and two coats of primer of approved 3721.00 Sqm 40.59
brand and manufacture on new wall surface to give an even
shade including thoroughly brushing the surface free from
mortar dropping and other foreign matterand sand papered
[68] Wall painting (Three coats) with plastic emulsion paint ( Asian 3721.00 Sqm 125.40
paint Royale or equivalent ) of approved brands and
manufacture on undecorated wall surfaces to give an even shade
including thorougnly brushinf the surface free from mortar
droppings and other foreign matter and sand papered smooth
including Applying two coats of Birla or Asian acrylic lappy (purty)
and two coats of primer of approved brand and manufacture on
new wall surface to give an even shade.
[69] Finishing wall with Weather Proof Acrylic Emulsion Water 3114.00 Sqm 120.26
Repelant Paint on wall surface (two coats) to give an required
shape even shade after thoroughly brushing the surface to
rempve all dirt, and remains of loose powdered materials etc
[70] Providing laying and jointing in true line and level 110 mm dia. 497.00 Mtr 876.90
U.P.V.C. SWR Type B pipe conforming to IS 13592-1992 with one
end plain and other end socketed with rubbering & fitting
conforming to ISI 14735- 1999 of approved make for drainage
system pipe line, pipe shall be jointed with each other with
rubber lubricant.Pipe shall be fixed on the wall using of PVC
clamp of the size 110 mm dia X 149 mm length X 145 mm
high at every 2000 mm center to center or shall be concealed in
wall as directed including necessary fittings such as bends,
shoes etc. including testing of pipe and joints and jointed with
adhesive solvent cement, including cost of all materials.
[71] Providing laying and jointing in true line and level 160 mm dia. 278.00 Mtr 834.38
U.P.V.C. SWR Type B pipe conforming to IS 13592-1992 with one
end plain and other end socketed with rubbering & fitting
conforming to ISI 14735- 1999 of approved make for drainage
system pipe line, pipe shall be jointed with each other with
rubber lubricant.Pipe shall be fixed on the wall using of PVC
clamp of the size 160 mm dia X 210 mm length X 196 mm
high at every 2000 mm center to center or shall be concealed in
wall as directed including necessary fittings such as bends,
shoes etc. including testing of pipe and joints and jointed with
adhesive solvent cement, including cost of all materials.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[72] Providing laying and jointing in true line and level 50mm dia. 107.20 Mtr 195.67
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings
as approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concelled as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
[73] Providing laying and jointing in true line and level 40mm dia. 86.00 Mtr 148.12
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings
as approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concelled as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
[74] Providing laying and jointing in true line and level 25mm dia. 162.00 Mtr 91.84
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concelled as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
[75] Providing laying and jointing in true line and level 15mm dia. 84.80 Mtr 72.65
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concelled as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
[76] Providing and fixing concealed center point to wall ceiling & 17.00 Mtr 170.36
floor CPVC (SDR 13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water of following dia.
nominal bore tube fittings and clamps including making good
the wall, ceiling and floor etc. complete.[A] 15 mm.
[77] Providing and fixing concealed center point to wall ceiling & 31.00 Mtr 253.82
floor CPVC (SDR 13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water of following dia.
nominal bore tube fittings and clamps including making good
the wall, ceiling and floor etc. complete. [C] 25 mm.
[78] Providing and Fixing 50mm dia PVC Heavy Duty valve of approved 5.00 No 1097.62
quality with required fitting and adhesive incl. fixing the same
with new or existing line as directed by EIC.
[79] Providing and Fixing 40mm dia PVC Heavy Duty valve of approved 12.00 No 975.66
quality with required fitting and adhesive incl. fixing the same
with new or existing line as directed by EIC.
[80] Providing and Fixing 25mm dia PVC Heavy Duty valve of approved 20.00 No 708.52
quality with required fitting and adhesive incl. fixing the same
with new or existing line as directed by EIC.
[81] Providing and Fixing 15mm dia PVC Heavy Duty valve of approved 9.00 No 633.02
quality with required fitting and adhesive incl. fixing the same
with new or existing line as directed by EIC.
[82] Providing and fixing C.P. brass shower rose with 15mm or 20mm 8.00 No 282.16
inlet.(A) 100mm dia. Each
[83] Providing and fixing 600mm x 450mm bevelled edge 13.00 No 835.70
mirrror of superior glass mounted on 6mm thick A.C.
sheet or plywood sheet and fixing to wooden pluge with C.P.
brass screws and washers
[84] Providing and fixing screw down bib taps of following size.(B) 34.00 No 214.81
Brass chromium plated screws down Bib Tap. (ii) 20mm dia.
[85] Providing and fixing Urinal of approved quality including 13.00 No 1560.15
connection with trap and with integral longitudinal flush
pipe.(A) Squating plate pattern white earthenware 550mm x
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[86] Providing and fixing Water closet squatting pan ( Englow Indian 4.00 No 2478.63
type W/C pan ) size 580mm. including earthwork, footrest,
mm dia. "P" or "S" trap, inletconnection for flush pipe and
chromium plated brass half turn flushing valve 25mm.dia. W.C.
Pan Vitrious China Long Pattern.
[87] Providing and fixing wash down water closet (European type, W.C. 16.00 No 4341.91
Pan )with integral 'P' or 'S' trap including jointing the trap with
soil pipe in cement mortar 1:1 (1 cement : 1fine sand)
including providing and fixing wash down water closet with C.P.
Brass hinges and rubber buffers including Providing and
fixing Jet Sprey , Seat Cover, 15mm dia angel Valveof approved
quality etc. complete.
[88] Providing and fixing wash basin with single hole for pillar tap with 18.00 No 2208.68
C.I. Or M.S. brackets painted white including cutting holes and
making good the same but excluding fittings
:(ii) Flat back wash basin 500mm x 400mm size including 15mm
dia Pillar Tap, Waste pipe, M.I Fisher Union, 15mm dia stop cock
[89] Providing and fixing Brass polished Bright Soap Dish Holder 9.00 No 1103.43
of approved pattern, quality and design incl. all labour, tools,
machineries etc. complete as directed by Engineer-in-Charge.
[90] Providing and fixing C.P. brass towel rail comlete with C.P. 10.00 No 604.51
brass brackets fixed to wooden plugs with C.P. brass scews.(B)
600mm x 20mm size.
[91] Providing and fixing 600mm x 120mm glass shelf with C.P. brass 9.00 No 517.00
bracket and guard rail complete mixed to wooden plug with
C.P. brass screws.
[92] Providing and fixing Brass polished Bright Hanger / Khinti of 9.00 No 592.37
approved pattern and design incl. all labour, tools, machineries
etc. complete as directed by Engineer-in-
[93] Providing and fixing Kitchen SS Sink Glosy ASIS 304 Grade 1mm 1.00 No 2353.34
thick with overall size 610 X 460 mm & Bowl size 560X410X200
with C.I. or M.S. Brackets, painted white including cutting holes
in walls and making good the same etc. complete.
[94] Providing and Fixing Stainless Steel(Grade- 316) accessories, 2.00 No 2946.15
Sheet Cutlery Basket of size:520X485X100 mm .fixing on
telescopic channel of length 500mm having hardware like
handles, dead lock etc. for Kitchen of Approved Brand as
directed by Engineer in charge.
[95] Providing and Fixing Stainless Steel (Grade- 316)accessories, 4.00 No 3050.68
Thali Basket & Cup Saucer Basket of size:520X485X150 mm
.fixing on telescopic channel of length 500mm having hardware
like handles, dead lock etc. for Kitchen of Approved Brand as
directed by Engineer in charge.
[96] Providing and Fixing Stainless Steel(Grade- 316) accessories, 2.00 No 2771.92
Plain Basket of size:520X485X150 mm .fixing on telescopic
channel of length 500mm having hardware like handles, dead
lock etc. for Kitchen of Approved Brand as directed by Engineer
[97] Providing and fixing PVC SWR Nahni Trap IS 14735 for drain - 25.00 No 585.80
100 mm diameter with jali of the following nominal diameter of
self cleansing design with C.I. Scread down or hinged grating
including the cost of cutting and making good the wall.
[98] Providing and fixing S.W Gully trap with C.I grating brick 6.00 No 1246.92
masonary chamber and water tight C.I.cover with frame of
mm x 300 mm size (inside) with standard weight. (i)Square
mouth traps.(B) 150 mm x 100 mm
size -P or R type.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[99] Constructing brick masonry road gully chamber 1100mm x 4.00 No 8767.25
500mm x 775mm including 500mm x 450mm C.I. horizontal
grating with frame and vertical grating
[100] Constructing brick masonary chamber for underground C. I. 4.00 No 2932.93
Inspection chamber and bends with bricks having crushing
strength not less than 35kg./sq. cm. In C. M. 1:5 C.I. Cover with
frame (lightn duty) 455 x 610 mm internal dimensions. Total
wt. of cover with frame to be not less than 38kg. (weight of cover
23 kg. & wt. of frame 15kg.) R. C.C. top slab with 1:2:4 (1
cement :2 coarse sand :4 graded stone agg. 20 mm. nominal
size) foundation concrete 1:5:10. Inside plaster 15 mm thick
with C. M. 1:3 finished smooth with a floating coat of neat
cement on wall & bed concrete etc. comp. (i) inside dimensions
455 x 610 mm. x 450 mm. deep for single pipe line.
[101] Providing sock pit of 5.0Cu.M. volume including excavating 2.00 No 3457.27
sand filling brick bats with dry masonry work at top for 45cm
height including covering the top with stone including providing
vatas in C.M. 1:3 with finishing curing etc. complete as directed.
[102] Providing and Constructing Septik Tank of 7.20 x 3.46 x 2.50 ( 1.00 No 148693.48
outer diemnsions) and 6.74 x 3.00 x 2.5 ( inner dimensions )
including necessary excavation, 15cm thick B.B.C.C. in bottom of
the tank, providing 23cm thick brick masonary outer wall in
C:M 1:6, 2 Nos of partition wall of half brick masonary in
C:M 1:5, RCC Slab in 1:2:4 with reinforcement as directed,
15mm cement plaster on inside surface of brickmasonary,
Verticle cement vata on each corner of the wall,110mm dia. PVC
pipe in bottom etc.complete incl. all labour, material
, excavation etc. complete as per detail drawing and
instruction given by Engineer- in-Charge.
[103] Providing erecting and fixing tripple coated PVC water tank of 19000.00 Liter 10.22
required capacity each including necessary transportation to
the site, making plateform with matching flooring to the
terrace, fixing fitting and connecting to inlet and outlet
with all necessary fittings & connection complete on terrace.
[104] Providing and fixing ball cock of approved quality as 3.00 No 189.84
directed.(A) Vitreous china (ii) Copper metal- 50 mm.
[105] Providing and Fixing 18 mm thick Plywood SHUTTER for Cupboard 5.00 Sqm 7032.54
or Below platform shutter using 18mm thick plywood covered
with 1.00 mm thick laminates both side. Exposed face should
be covered with 1.0 mm thick laminate of approved quality
and pattern, colour, texture the rest of the inside surfaces, shelves
etc. shall be finished with 0.80 mm thick white laminates of
approved make, wooden framing shall be used including
alround framing of 19 mm X 12 mm teak wood member at all
borders and in the centre where ever, all the sides of the
shutter should be covered with teakwood battens and
provided with necessary framing, best quality SS channels for
sliding, SS finished hinges, hadles, megnet, deadlock etc.
as approved and directed by Engineer-In-Charge.
[106] Providing and Constructing JUNCTION CHAMBER of size 0.35 x 34.00 No 3113.41
0.35 x 0.60 m. including connecting rainwater pipes, Half brick
work with 15mm thick plaster in C;M 1:4, 50mm thick C.C. 1:2:4 in
bed flooring & covered with Precast RCC slab cover 100mm thick
incl. all labour, material , excavation etc. complete.
[107] Providing & Constructing FILTER CHAMBER of size 2.06 x 1.21 x 8.00 No 11936.27
1.20 m. including connecting rainwater pipes, half brick work with
15mm thick plaster in C;M 1:4, 50mm thick C.C. 1:2:4 in bed
flooring & covered with Precast RCC slab cover 100mm thick incl.
all labour, material , excavation etc. complete.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[108] Providing & Constructing PERCOLATION SOCKWELL of 2.54 m 4.00 No 53911.09
internal clear diameter and 5.00 mt. depth incl. honey comb brick
masonary in C:M 1:C, 15mm thick plaster in C;M 1:4, 50mm thick
C.C. 1:2:4 in bed flooring & covered with RCC top slab 100mm
thick incl. filling with greval etc. complete incl. all labour, material
excavation etc. complete.
[109] Steel work welded in build up sections,framed work 27.00 Qtl. 9108.48
including cutting, hoisting fixing in position and applying a priming
coat of red lead paint A) In beams and joists, channels,
angles,tees, flats with connection plates or angle cleats as in
main and cross beams, hip and trussed purlins connected
to common rafters and the like.
[110] Providing and Fixing 6 mm thick Lexan Polycarbonate multi wall 85.00 Sqm 1441.90
roofing sheet fixed with hilti screw and rubber silicon sealer and
alluminium strip of size 50 x 3 mm etc complete as directed
by Engineer in charge.
[111] Applying priming coat over new steel and other metal surface 85.00 Sqm 36.74
after over and including preparing the surface by thoroughly
cleaning oil, grease dirt and other foreign matter and scoured
with brushes fine steel wool, scrapers and sand paper with
ready mixed priming paint brushing red lead.
[112] Painting two coats (excluding priming coat) on new steel 85.00 Sqm 92.20
and other metal surfaces with enamel paint brushing, interior
to give enamel paint brushing, interior to give an even shade
including cleaning the surface of all dirt, dust and other foreign
[113] Providing and laying cement concrete 1:3:6 (1- Cement : 9.00 Cum 4152.60
3- Coarse sand : 6- crushed stone aggregates 20 mm
nominal size) and curing complete including cost of formwork in
(A) Wall Caps / Coping.
[114] Providing and fixing M.S. grills of required pattern to wooden 454.00 Kg 153.20
frames of windows etc. with M.S. flats at required spacings
and frame alround, square or round bars with round headed
bolts and nuts or by screws.
(B) ORNAMENTAL GRILL
[115] Providing and fixing 1.20 Metre high fencing with 2.0 Metre long 248.00 Mtr 391.93
M.S. Angle posts 40mm x 40 mm x6 mm and oil painting 3 coats
fixed at 2.5 Mt,C/c. with five Horizontan lines and two diagonals
of galvanised steel barbed wire weighting 9.38 Kg. per 100 Metre,
strained and fixed to posts with G.I,staples including fixing
the postsin ground with 0.5 M x 0.5.M x 0.5 M. block in C.C1:5:10
[116] Box cutting the road surface to proper slope and camber for 589.90 Cum 109.41
making a base for road work including removing the excavated
stuff and depositing on the road side slope as directed upto all
[117] Providing, laying, spreading and compacting stone 292.70 Cum 1021.11
aggregates of specific sizes to WBM Grade-I specification using
63mm to 45mm metal (@ 0.91cum per 10 sqmt loose qty) with
stone screening of 11.2mm (@ 0.18cum per 10 sqmt loose qty)
and stone dust (@ 0.06cum per 10 sqmt loose qty) as filler
material, including spreading in uniform thickness, with
consolidation by vibratory roller in stages to proper grade and
camberm applying and brooming requisite type of screening
/ binding materials to fill up the interstices of coarse aggregate,
watering and compacting to the required density as per MoRTH.
(By Mechanical Means). as directed by the Engineer in Charge.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[118] Providing and cast in situ ordinary cement concret M-250 for 184.80 Cum 6407.44
average 20 cm thick wearing coat / C.C. pavement laid as
directed in approved fixed side form work of steel channel
including vibrating by screed-needle vibrator and finishing
by plate vibrator and finished in continous operation
including providing of contraction joint at every 4.00mtr
and expansion joint at interval of 40 mtr applying
debonding strips,bitumen primer,bituminous sealant,12 mm
rope and curing etc. complete.
[119] Providing and fixing pre-cast concrete kerb stone of gray cement 91.00 Mtr 402.55
based concrete block 30cm length,30cm height and 15cm thick of
M250 grade concret as per approved design and including
excavation for fixing in proper line and level,filling the joint
with C:M 1:3 (1cement:3fine sand) etc complete.
[120] Providing and fixing in position FE 500D TMT bar 2.77 M.T. 73243.02
reinforement including cutting, bending and tying complete as
per detailed drawings. (A) R.C.C. Kerb. (B) R.C.C. Footpath.(C)
R.C.C. Approch slab.(D) Wearing Coat.
[121] Supplying and fixing reinforced concrete heavy duty non- 36.00 Mtr 659.99
pressure pipes with collars for culverts carrying heavy traffic as per
IS 458-1991 specifications including setting the pipes in C.M.
1:2 watering and laying (to level or slopes) of class NP3
of following internal daimeters.(i) 300mm dia.
[122] Drilling of 200 / 215 mm dia bore in over burden rocky or loose 40.00 Mtr 418.14
collapsible / boulder strata and lowering of UPVC / PVC / ERW
casing pipe above 12 mt and upto 40 mt depth by DTH rig etc
[123] Drilling of 200 mm dia bore hole by DTH rig in rocky formation in 200.00 Mtr 489.85
All takuka of Zone III ( o to 350 Mtr )
[124] Supply of "U" PVC Casing pipe CM type (B) 200 mm dia 200.00 Mtr 1155.44
[125] Providing and fixing bail plug {Bottom Cap } Suitable for 200mm 1.00 LS 830.27
[126] Heavy duty clamp made from 4" x 1.5" iron strip suitable for 1.00 No 242.40
column pipe 1.5" to 2" length. (C) 65mm(2.1/2") dia. Pipe
[127] Supplying & erecting G.l. bend for pipe connections suitable for 1.00 No 236.34
[128] Supplying, & erecting C.I. swing, check type non-return (Reflux) 1.00 No 1757.40
Valve -ISI marked suitable for following size (B) 65 mm dia.
[129] Supplying submersible pump set Electric motor driven borewell 1.00 No 45732.80
submersible pump set confirming to IS 8034 and motor
confirming to IS 9283 working at 3 phase 400 / 440 volt 50 Hz AC
supply & 2900 RPM. (25) Cat o. 6.3, Discharge 400 LPM, 150 Mtr
[130] Auto transformer starter suitable for local & remote pump control 1.00 No 24518.76
application consisting of Auto Transformer (vacuum impregnated,
air cooled having three (3) tappings at 50%, 65% and 80%),
incomer MCCB / MPCB, overload relay and contactors as per Type
II including digital MFM with RS 485 communication port,
analogue type ammeter with selectorcoordination switch, run
hour meter, required protective relays & control accessories.
[131] Providing and erecting ISI marked PVC insulated flat 560.00 Mtr 195.94
submersible cable as per detailed technical specifications of R/C of
GWSSB conforming to IS 694, IEC 60227 / 60228.(e) 1 R x3 Core x
[132] Providing & fixing of ISI marked HDPE Pipes suitable for potable 160.00 Mtr 154.38
water as per IS specifications no 4984/1995 including SS-316
nipple at both ends having 11 TPI threads as per specifications,
press fitted and bolted incl all taxes, transportation, freight
charges, inspection charges, loading, unloading along with
lowering and laying the pipe including the cost of all labour &
material for 63mm dia ( PN-10) 10.00 kg/cm2 pipe.
[133] Geohydrological ground water investigation including vehicle 1.00 No 14428.86
charges (b) For three phase DTH bore / DR tube well including
water sample testing charges.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[134] Providing & erecting Monobloc pump 3 phase 400/440 volt, 50 Hz 1.00 No 16483.20
AC Supply & 2800 RPM as per IS 9079 at departmental stores
with following MOC: Casing: CI-FG260, Impeller: Bronze & Shaft:
SS:410 @ 24 Mtr head, 285 LPM Discharge, 5-HP
[135] Supplying & erecting approved make DOL / Star Delta starter 2.00 No 8466.83
suitable for local & remote pump control application consisting of
MPCB, overload relay and contactors as per Type II coordination
including digital voltmeter, analogue ammeter with selector
switch, run hour meter, required protective relays & control (C)
[136] Providing and laying controlled cement concrete M-250 and 9.65 Cum 6161.40
curing complete incl. the cost of formwork but excluding
reinforcement for reinforced concrete work in Walls from top
of foundation level For Ground Floor.
[137] Providing and laying Ceramic tiles 6mm thick in flooring treads of 13.00 Sqm 992.15
steps and landing laid on a bed of 12mm thick cement mortar
1:3 (1-cement : 3- coarse sand ) finishing with flush pointing in
white cement. .
[138] Providing and fixing FRP Frame size 125X65mm and 35mm thick 2.60 Sqm 2615.04
FRP shutter with wodden grain raized pannel design finish
shutter having extra reinforcement on side and edges and in
polish finish. The core of the shutter is to be filled up with
injected fire extinguishing grade polyurethane foam
done in situ alongwith embedded wooden pieces for
stiffening and also for taking hines and fixstures. Thje whole
FRP Frame and shutter is to be water proof, termite proof and
resistance to mile acid/ Alkali. Rates are to be inclusive S.S. hinges
with necessary screws and alluminium fixture and fastening.
[139] Distempering (Two coats) with oil bound distemper of 74.00 Sqm 75.68
approved brand and manufacture and of required shade on wall
surface to give an even shade over and including a priming coat
with distemper primer of approved brand and
manufacture after thoroughly brushing the surface free from
mortar dropping and other foreign matter and also including
preparing the surface even and papered smooth
[140] Providing and fixing C.I. Manhole cover 0.60mm x 0.45mm size 2.00 No 958.17
having weight not less than 35Kg.
[141] Providing and fixing cast iron steps of size 500mm x 150mm x 8.00 No 151.50
22.5mm and painting with two coats of Anti-corrosive paint etc.
[142] Providing and fixing screw down bib taps of following size : 3.00 No 186.82
(B) Brass chromium plated screw down bib tap
[143] Providing and Fixing brass chromium plated bright finished 15mm 1.00 No 696.90
dia. Push Cock specialy designed for urinal of approved quality
directed by EIC.
[144] Providing and fixing S.W. gully trap with C.I. grating brick 1.00 No 1292.19
masonry chamber and water tight C.I. cover with frame of
300mm x 300mm size (inside) with standard weight.(i)
Square mouth traps. (A) 100mm x 100mm size P type.
[145] Painting Two coat (excluding priming coat) on previously painted 5.00 Sqm 100.25
steel and other metal surfaces with enamel paint brushing to
give an even shade including cleaning the surface of all
dirt, dust and other foreign matter.
[146] Clearing and grubbing road land includinguprooting rank 0.26 Hec. 27924.38
vegetation grass bushes, shrubs, sapling and trees girth upto
300 mm removal of stumps of trees cut earlier and disposal
of unservicable materials (C.) By meachanical means in area
of light jungle
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[147] Rolling & watering of earthwork in layers with vibratory roller 716.00 Cum 22.96
including filling in depressions which occurs during the process
[148] EXECUTIVE TABLE 2000mm x 850mm x 3.00 Set 22038.64
750mm with side unit 1200mm 400mm x 750mm : Providing
and supplying Main Table made with 19mm thk. plywood
structure as per architect drawing finished with 1.0mm thk.
decorative laminate on outside portion & 0.8mm thk. liner
Laminate inside as specified & approved by architect fixed with
necessary fixtures and fastening (Hardware) as per architect
drawing. Provide Plastic Computer Desk Table Grommet Cable
Wire Outlet Hole Cover 60mm, Key-board trey, S.S legs,
Drawers with telescopic roller channels , Handle and Locking
arrangements with all necessary fixtures and fastening . Provide
shutters as per drawing fixe with handle , Hinges , magnet
complete with bidding patties and all required hardware . provide
footrest as per drawing. all exposed shall be covered with required
Teak wood beading patti finished with appproved melamine
polishing work. complete as per architect drawing and as per
instruction of architect & engineer in charge.
[149] OFFICE TABLE of required size : Providing and supplying 52.47 Sqm 13104.79
Table made with 19mm thk. plywood structure as per architect
drawing finished with 1.0mm thk. decorative laminate on outside
portion & 0.8mm thk. liner Laminate inside as specified &
approved by architect fixed with necessary fixtures and fastening
(Hardware) as per architect drawing. Provide Plastic Computer
Desk Table Grommet Cable Wire Outlet Hole Cover 60mm, Key-
board trey, Soft-board, S.S legs, Drawers with telescopic roller
channels , Handle and Locking arrangements with all necessary
fixtures and fastening . Provide shutters as per drawing fixe with
handle , Hinges , magnet , complete with bidding patties and all
required hardware . provide footrest as per drawing. all exposed
edges shall be covered with required Teak wood beading patti
finished with appproved melamine polishing work. complete as
per architect drawing and as per instruction of architect &
engineer in charge.
[150] Conference Table, Table Size: As required 20.70 Sqm 12988.07
: Providing and supplying Conference table made with using
19mm TH Plywood . structure finshed with 1.0mm TH
decorativelaminate sheet approved by architect & nylon
adjustors fixed with necessary fixtures and fastening (Hardware)
as per architect drawing.Top portion of conference table all
edges shall be covered with required Teak wood beadig patti or
Molded Laminate sheet finished with approved melamine
polishing work. The table shall also provision for carrying wires &
mounting electrical plug point, switches & milk etc. Complete as
per architect drawings and as per instruction of architect &
engineer in charge.
[151] Work Station / Operator Table of required Size : Providing 4.00 Sqm 17373.95
and supplying Reception table made with using 19mm thk.
plywood structure finished with 1.0 mm thk. decorative
laminate sheet approved by architect fixed with necessary fixtures
and fastening (Hardware) . Top portion of table alledges shall be
covered with required teak wood beading patti finished with
approved melamine polishing work. Complete as per architect
drawings and as per instruction of architect & engineer in charge.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[152] STORAGE UNIT / CUPBOARD : Providing and Fixing Full / Low 36.00 Sqm 11161.51
Height Storage Unit as per drawing to be made from 19mm thick
Plywood structure and finished with 1.0 mm thick Decorative
Laminate Sheet on outside and 0.80mm thick liner laminate inside
as specified and approved by architect fixed with necessary
fixtures and fastenign as per architect drawing. The shutter shall
be fixed with required handle, hinges, magnet and locks complete
with bidding patties and all required hardware. Ply shelves
removable type supported on side tak wood battens on both side.
all exposed edges shall be covered with 8mm thick teak wood
beading patti finished with melamine polish. etc. complete as per
architect's drawing as per instruction of architect & engineer in
[153] Supplying and fixing 8mm thick Acrylic sheet ( Cast Quality ) for 3.00 No 5096.87
Incumbency Chart incl polishing the edge and finishing the
sheet with approved shde radium font and of directed design and
pattern and fixing the same with required S.S. sturd as directed by
[154] Notice Board: Size: 120cm Wide x 168cm High and 2.00 No 5676.20
Overall Display Height:203cm. Specification: Portable Loop
Fabric Panel Floor Display Stand.
(a) Panel Dimensions: 120cm wide x 168cm High. (b) Overall
Display Height:203cm (c) Panel Display frame finishes: light gray
or beige. (d) Loop
fabriccolors available:.
[155] HIGH BACK revolving & tilting EXECUTIVE CHAIR : 3.00 No 7272.00
Providing and Supplying High back Chair for conference with M.S
frame work. Upholstered with Artificial leather/Leatherette and
molded PU foam, together with molded seat & back covers. The
back foam should be designed with contoured lumber support fo
extra comfort. Caster of high durability & hydraulic. The chair
should have cylinder with 5 years" warranty. The size of chair
53cm x 79cm (back side) and 51cm x 49cm (seat size). The PU form
should be molded with density=45+ 2 kg/m3. with One piece
armrests are scratch and weather resistant. The permanent
contact mechanism is designed with 360⁰ revolving tyep, 12⁰ seat
tilt 19⁰ back tilt, Front pivot for tilt with feet resting on groind
ensuring more comfort, Tilt tension adjustment, 5 position locking
with anti-shock back mechanism, Which should prevent the
backrest from impacting the user when the lock is released, static
seat depth adjustment=0.5 cm 5 position locking.
[156] MEDIUM BACK revolving & tilting CHAIR : Providing and 13.00 No 6363.00
supplying Medium back chair for conference with M.S frame wrk.
Upholstered with changeable fabric upholstery covers(as per
requirement) and molded PU form, togrether with molded seat
& back covers. The back form should be designed with contoured
lumber support for extra comfort. Caster of high durability &
hydraulic. The chair should have cylinder with 5 yearsʼ warranty.
The size of chair
47.5cm x 58cm (back side) and 49cm x 48cm (seat size). The PU
form should be molded with density =45 ± 2 kg/m3. With One
piece armrests are scratch and weather resistant. The
permanent contact mechanisms is designed with 360⁰ revolving
type, with pneumatic height adjustment & 17⁰ maximum tilt only
& tilt tension adjustment facility.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[157] LOW BACK revolving & tilting CHAIR :. Providing and 44.00 No 4545.00
supplying Low back chair for work center & other staff the seat &
back are made of M.S frame work. Upholstered with changeable
fabric upholstery covers (as per requirement) and molded PU
form, together with molded seat & back covers. The back foam
should be designed with contoured lumber support for extra
comfort. Caster of high durability & hydraulic. The chair should
have cylinder with 5 years warranty. The size of chair 45cm x 45cm
( back side) and 45cm x 43cm (seat side). The PU form should be
molded with density =45 ± 2 kg/m3. with One piece armrests. The
armrests are scratch and weather resistant. The permanent
contact mechanisms is designed with 360⁰ revolving type, with
pneumatic height adjustment & 17⁰
maximum tilt only & tilt tension
[158] VISITOR CHAIR : Providing and supplying Visitor or Guest chair 63.00 No 4090.50
the seat & back are made 12mm thick hot pressed plywood
upholstered with changeable fabric upholstery covers (as per
requirement) and molded PU foam, together with molded seat
& back covers. The back foam should be designed with contoured
lumber support for extra comfort. The size of chair 45cm x 38cm
(back side) and 45cm x 43cm (seat side). The PU foam should be
with powder coted MS structure as per architect selection. The
seat and back fixed with MS structure with required necessary
[159] THREE SEATED SOFA : Providing and supplying sofa. (3 seated) 8.00 No 18180.00
made with using 19mm thk. plywood structure frame with
S.S legs required necessary support fixed with necessary fixtures
and fastening (Hardware) . it shall be covered with 32 density PU
foam) with required Thickness as per design in seat & back and
handle portion this should be again covered with 14mm thick PU
foam with Madarpat cover on it & upholstered fabric or leather of
suggested & approved by architect finished with seat, back & all
visible side as per architect drawing. Complete as per architect
drawing and as per instruction of architect & engineer in charge.
[160] TWO SEATED SOFA : Providing and supplying sofa. (2 seated) 8.00 No 12726.00
made with using 19mm thk. plywood structure frame with
S.S legs required necessary support fixed with necessary fixtures
and fastening (Hardware) . it shall be covered with 32 density PU
foam with required Thickness as per design in seat & back and
handle portion this should be again covered with 14mm thick PU
foam with Madarpat cover on it & upholstered fabric or leather of
suggested & approved by architect finished with seat, back & all
visible side as per architect drawing. Complete as per architect
drawing and as per instruction of architect & engineer in charge.
[161] Centre Table/ Corner Table/Tipoi. : Providing and supplying 5.00 No 3363.30
Center Table/Corner Table/Tipoi with Glass top made with 19mm
thk. plywood finished with 1.0 mm thk. Decorative laminate sheet
specified and approved by architect & fixed with necessary
fixtures and fastening (Hardware) inclusive of approved
melamine polishing work. Top part of center table covered with
8mm thk. toughened Glass with polished Edges. Complete as per
architect drawing and as per instruction of architect & engineer in
[162] Roller blinds : Providing & supplying Roller Blinds assemblies 119.50 Sqm 2090.70
are to be supplied & installed in all windows with great precision
it should be water resistant and fitted on aluminum head rails duly
powder coated and fitted with stainless steel drive rods. Manual
operated and should have ISI mark. Complete or as directed as per
architec & engineer in
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[163] Providing Stainless Steel Dust Bin in cylindrical shape with steel 3.00 No 1090.80
pedal and lid Garbage bin for washroom , kitchen, bathroom and
office of size 7 " x 11' - 05 Litre as directed by Engineer-in-Charge.
[164] Providing and Arranging Three Seater Gang Seater having seat and 2.00 No 9090.00
back made from CRCA Tubular frame welded with perforated
Diemoulded CRCA sheet. base frame made from round Tubular
welded with horizontal beam Two side armrest welded with frame
including finishing metal parts with epoxy polyster powder
coaating of 50 micron thickness Including all materials and labour
etc. Complete as per drawing and instruction ofengineer- incharge
& overall weight of unit shall not be less than 35 kg. 3 Seater
S.S.Gang Seater: size-1590mm x 480mm x 880mm (H)
[165] Providing and fixing decorative wall Murral type nation emblem ( 3 1.00 No 67023.03
lions design with "સcયમેવ જયતે" ) made out of first class
teakwood incl . carving the emblem on wood using advance CNC
cutting auto machine nad applying 2 nos of 19mm thick marine ply
to backside and approved qaulity rope -light to give lighting effect
to back side of the arved emblem and applying the carved mblem
with melamine polish and fixing the same on wall as directed by
Engineer-in-charge. Size 670mm x 1170mm x 79mm
[166] Podium Size: 580x 380 x 1100 mm : Providing and supplying 1.00 No 11761.45
Podium made with using 19mm thk plywood structure finished
with 1.0mm thk decorative laminate sheet apporoved by
architect fixed with necessary fixtures and fastening (Hardware) .
all edges shall be covered with required teak wood beading patti
finished with approved melamine polishing work. the podium
shall also provision for carrying wires & mounting electrical plug
point, switches & mike etc. Complete as per architect drawings
and as per instruction of architect & engineer in charge.
[167] Providing, supplying & fixing SS letters of specified size, pattern, 800.00 CM 109.08
matter, language, font, style etc. made from 16 Guage thick
grade stainless steel with 8% Nickel including fixing the letters to
any surface at any height, making good the surface etc. complete
as directed and as per detail
[168] Key Stand: Size: 60 x 70 cm. Features: 1.00 No 5454.00
(a) Convenient way for storing keys with door lock. (b) Door cover
with locking method for security purpose with glass ( as per
instruction of architect & engineer in charge).
[169] Pin Up Board Size : 600 x 300 mm : Providing and fixing pin 1.00 No 1090.80
up board of required size as per instruction of architect & engineer
[170] Supply Installing Testing & Commissioning of 7.50 HP Monobloc 1.00 No 46308.50
pump 3 phase 400/440 volt, 454 LPM Discharge, 24 meter
head, 50 Hz AC Supply & 2800 RPM as per IS 9079 at
departmental stores with following MOC: Casing: CI-FG260,
Impeller: Bronze & Shaft: SS:410 including all requirede fittings,
rubber ring, flange, nuts, bolts and labour etc complete as directed
and certified by Engineer in charge.
[171] Supply Installing Testing & Commissioning of 100 NB M.S. Pipe 43.00 Mtr 2148.78
Class B, ISI Marked, Make : Asian, Tata, Jindal, Supply
Fabrication ( Including civil work like making hole, soil
remove etc.) Installation, painting, Fitting ( i.e Elbows, Tee,
Reducer Coupling Flanges, Nipple etc.) with proper supports
including structural and civil costructed, Nut, Bolt and
washer, Gasket, Fabricated piping with fitting must be Tested
for any leakage and Hydraulically tested at 15kg/sqcm and it
must be satisfied and certified by Engineer in charge.
[172] Supply Installing Testing & Commissioning of 100mm Dia 2.00 No 5226.75
Double Flanged ISI-Mark C.I Sluice / Butterfly Valve with gun
metal / SS working part,stainless steel spindal, Gasket, Nut Bolts,
etc. necessary complete.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[173] Supply Installing Testing & Commissioning of 100mm Dia 1.00 No 11673.08
Double Flanged ISI-Mark C.I Non-Return Valve with Gasket, Nut-
Bolts, etc necessary
[174] Supply Installing Testing Commissioning of 100mm dia "Y" Type 1.00 No 15157.58
Stainer ISI-Mark with Gasket,Nut Bolts, etc .necessary complete.
[175] Supply Installing Testing & Commissioning of 25mm Dia ISI-Mark 2.00 No 1858.40
C.I Ball Valve with gun metal / SS working part,stainless steel
spindal, Gasket, Nut Bolts, etc. necessary complete.
[176] 25mm Dia Air Valve for Riseing Main Line. For Air Release 1.00 No 2555.30
Including supply, Installing, Testing And Commissioning etc.
[177] Supply Installing Testing & Commissioning of Pressure 1.00 No 1916.48
Guage 100mm Dia. 1 % Accuracy Direct Bottom 3/8” BSP
connection In Brass Socket & Range 0 to 16 Kg/Cm2 etc
[178] Supply Installing Testing & Commissioning of 63mm Dia C. I. 1.00 No 6969.00
TWO WAY FIRE BRIDGE Inlet Valve with Gun-Metal Non-
Return, Flange, Gasket, Nut-Bolts, etc. Complete.
[179] Providing and fixing FIRST AID HOSE REEL wall mounting fix type 4.00 No 9408.15
having side of the hose reel made of MS , providing with
30mtr long 25mm dia PVC nylon braided flexible hose with S.S
shut off nozzle of approved quality etc complete as directed.
[180] Supplying and Fixing 4.5 Kg Fire Extinguisher, CO2 12.00 No 8362.80
Gas as per IS 15222 / ISI 15683 for fire classes BC &
Electrical Fire, Discharge Control mechanism fitted with high
pressure steel braided Discharge Hose and Flat Horn with
diffuser Nozzles for dispersed discharge of CO2, internal
coating not applicable & external coating of enamel spray
painting, Cylinders construction: hot spinning seamless & bearing
ISI mark, confirm to IS 7285 and PESO/CCOE Nagpur
approved. Fire Class 21B rating as per IS 15683 and ISI Mark.
[181] Supplying and Fixing Fire Extinguisher as per IS : 15683 with ISI 12.00 No 7549.75
Marked, Type : ABC, Capacity : 06 kg, Fire Rating : 4A, Stored
Pressure Type, Filled with 50% Mono Ammonium Phosphate
based multi purpose Dry Powder suitable for Class A, B & C
Fire, Pressurized by Dry Nitrogen, Complete with all
respect with stand/wall mounting bracket
[182] Supplying and Fixing Modular Wall Mounted ( with brackets ) 2.00 No 12544.20
portable Clean Agent HFC- 236fa 5 Kg gas based Fire
Extinguisher which leaves no residure making it safe for use
on sensitive equipment Extinguisher performance tested by
NABL accredited Lab, MSDS of the Extinguishing agent is a must
current and valid BIS certification 15683 2006, EN approved ISI
and GE approved / Marked. LPCB approved, EN:ISO:9001 & ISO
10002:2004 certified with 3 years warranty ) ( in / near
Electrical Panel Area )
[183] Providing of FIRE BUCKET WITH STAND which icludes a set of 4.00 No 10453.50
4 nos buckets with Capacity 09Ltr and a stand , G.I.24 Gauge,
Painted Red & Marked “FIRE” as directed.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[184] Supplying, Installing, Testing and commissioning of 1.00 No 335255.36
micro processor based intelligent addressable main
Zone FIRE ALARM CONTROL PANEL central processing unit at all
the Two floor with high intensity Hooter and manual call point
with hammer with the following loop modules and capable of
supporting minimum 120 detectors per loop and length up to
km. Alarm panel contains Zone wise Fire Fault LED indication,
Zone isolation facility, mains on system On, Charge on Visual
indications. Auto Dialer attached facility, External switch
for reset, silence, Lamptest, External Switch to test each zone
fire, open - short status manually, inbuilt Buzzer, inbuilt
battery charger & battery spaces. Operates on 230v AC,
HZ AC supply Fire alarm panel with resettable 02 nos of
manual call point for use in case of emergency for activate
the fire alarm system connected with 2 nos sounders and
70 nos of smoke detectors with base to address
[185] On/Off switch with pipe & 3c x 1 sq mm cable wiring ISI mark. 1.00 No 3850.23
[186] Providing & Fixing of Retroreflective High intensity grade on 6.00 No 1638.46
Acrylic plate of size 450mm 150mm made of 3 mm thick Acrylic
name plate with lettering using High intensity grade retro
reflctive letters, incl. fixing on each chamber as directed &
Instructed by Engineer- in- Charge.
[187] Supplying and Fixing of MARKING STRIPS are broadly used on the 1200.00 Sq.Cm. 6.97
roads, parking lots and many more places by manufacturer /
dealer to help/provide the right directions to the people in
making fast and immediate movement from the hazardous
places. Marking strips for stairs & walls : 120 x 5.7 cm size.
These strips are designed with the help of premium quality basic
material. It should have water proof, Tear resistance,
precisely designed, made of : Photo luminescent rig-id plastic,
2 mm thickness, printed on high quality gloss paint with UV
resistance, Material used : Non-Radioactive, non- phosphorous,
non-toxic and lead free, Time after removing the light source:
60 minutes, Luminescent intensity : 30 med/sqm,
Luminescent intensity greater than
mcd/sqm, period of light decay : 3100 minutes
[188] Supply, laying, testing & commissioning 1.1 kV grade, XLPE 90.00 Mtr 145.44
insulated, stranded Aluminium conductor, galvanised steel flat
strip / round wire armoured, extruded PVC type ST2 sheathed,
heavy duty cable (to be laid on wall surface with necessary clamps
/ in existing cable trench / cable trays / conduit / pipe
sleeves at road crossing or floor as per site requirement)
conforming to IS:7098 (Part-1) & IEC:60502 (Part-1) of
following sizes: (g) 3 Core x
[189] Supplying & Installation PRESSURE GUAGE of 150 mm dia. 0-21 1.00 No 2903.75
Kg/cm2 fitted with 12/15 mm dia pad cock valve and G.I.
complete as required.
[190] Providing and erecting IPVC insulated flat submersible cable 90.00 Mtr 124.23
as per detailed technical specifications of R/C of GWSSB
conforming to IS 694, IEC 60227 / 60228. (C) 3 Core x 4 Sq.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[191] Supplying & erecting approved make motor CONTROL 1.00 Job 13557.23
CUBICAL PANEL DOL / Star Delta starter suitable for local &
remote pump control application consisting of MPCB,
overload relay and contactors as per Type II coordination
including digital voltmeter, analogue ammeter with selector
switch, run hour meter, required protective relays & control
accessories. [C] D.O.L. up to 7.50 HP including Providing dust and
vermin proof MS cabin having two compartments, one for
panel board and other for energy meter and fuse unit with
required locking arrangement , minimum degree of protection IP
52 as per IS 2147 fabricated from CRCA sheer steel minimum
thickness for base frame / channel / gland plates for 3 mm for
load bearing members,1.6 mm for ineternal members of size
[192] Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 218.00 Pts. 485.81
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC
/ Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling
rose / H.D.Connector as directed. (f) with medium class Rigid PVC
pipe and accessories erected concealed in wall/ceiling complete
Cat III Light Point
[193] Bell Point 8.00 Pts. 485.81
[194] Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm 76.00 Pts. 674.68
(Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and accessories with
earth continuity of following type erected on PVC /
Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed. (f) with medium class Rigid PVC pipe
and accessories erected concealed in wall/ceiling complete Cat III
[195] Point wiring for Individual Plug with & earth wire of 1.5 sq.mm 18.00 Pts. 510.05
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate
front plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories.[I] For 6A Plug and 6 a
switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb
db board (f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
[196] Point wiring for on board Looped Plug with 6A Modular type 61.00 Pts. 257.55
switch & 5 pin socket erected on PVC / Metallic/Wooden box,
single mounting base frame covered with textured /
metallic/white front plate modules erected on / in wall / ceiling
with following type accessories Cat. III
[197] Providing following type of Modular Type Accessories mounted 10.00 Nos. 160.59
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge(3) Two Pin/RJ-11 Telephone Socket [A] For
One Gang Cat III
[198] (7) Blank Plate Single Cat III 100.00 Nos. 25.25
[199] (8) Computer RJ-45 socket Cat III 38.00 Nos. 160.59
[200] (9) 16 Amp. SP one way switch . Cat.III 17.00 Nos. 180.79
[201] (10) 6/16Amp. Universal socket Cat III 17.00 Nos. 199.98
[202] (19) Modular Indicating Call Bell 8.00 Nos. 329.26
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[203] Providing and erecting ISI mark Medium class RIGID PVC PIPES of 1495.00 Mtr 33.33
following size complete to be erected on/in wall or ceiling erected
with necessary PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in approved manner
as directed (b) 25 mm
[204] Providing & erecting PVC Corrugated Flexible Conduit with 100.00 Mtr 21.21
required nos. of coupling, PVC bushes, Check-nuts etc. complete of
following sizes. (2) 25 mm
[205] Supplying and laying UPVC cable trunking system comprising 50.00 Mtrs 188.87
unplasticised polyvinyl, chloride rigid material with ignition free
and flame proof confirming BS with necessary end caps Internal
and external bend, flat bends, coupler, tee etc..All necessary
accessories and measuring of following sizes (3) 50 mm x 50 mm
[206] Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated 1575.00 Mtrs 82.82
ISI marked stranded Copper conductor wire in following type of
pipe to be erected concealed in /flushed on wall/ceiling, with
sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size (A) With
medium class Rigid PVC pipe and accessorie (b) 2 wire 2.5 sq. mm
[207] Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated 200.00 Mtrs 260.58
ISI marked stranded Copper conductor wire in following type of
pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for
earth continuity of following size (A) with medium class Rigid PVC
pipe and accessoriese (h) 4 wire 6 sq. mm
[208] Providing & erecting Switch board for Computer or electric 41.00 Nos. 1133.22
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with single
mounting base frame covered with textured/metallic /white front
plate,modules erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories
[209] providing and erecting Mains with ISI marked, 1.5KV grade 9.00 Mtr 12.12
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with
required size of copper lugs, nuts and bolts if required.(a) One wire
[210] (e) One wire 6.00 sq. mm 56.00 Mtr 56.56
[211] (g) One wire 16.00 sq. mm 40.00 Mtr 142.41
[212] (i) One wire 35.00 sq. mm 16.00 Mtr 300.98
[213] Supplying and erecting Flexible PVC insulated multi strand multi 142.00 Mtr 46.46
core 1.1 kv grade ISI marked copper wires of following size to be
erected as directed.(e) 1.50 Sq.mm 3 core round PVC sheathed
[214] Supplying & erecting approved make Telephone Cable electrolytic 250.00 Mtr 20.20
copper conductor PE insulation twisted in two pairs, & wrapped
with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer
Jacket suitable for telephone wiring & confirming to C-DOT
erected in existing pipe. of following size of conductors & nos.of
pairs. With necessary connections.[A] Conductor Size 0.5 mm (a)
Unarmoured(2) Two Pairs
[215] (5) Ten Pairs 220.00 Mtr 65.65
[216] Supplying & erecting approved make LAN cable of following size in 1025.00 Mtr 47.47
existing pipe as per direction[C] CAT -
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[217] Providing & erecting main Distribution (MDF) indoor type, back 4.00 Ea. 994.85
mounted frame as per DoT standard approved with krone strips
(a) Suitable for 10 pair
[218] Supplying and erecting LED indoor fittings with LEDs of wattage 131.00 Ea. 535.30
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/ aluminium die cast powder coated and high U.V.
& corrosion resistance with diffuser with company mark/name
160V to 270V, Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.) (A) Tube Light with integral driver (v)
36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Cat-lll
[219] Supplying and erecting led lamps with following wattage capacity 18.00 Ea. 112.11
of 220 to 240 voltage, minimum 15000 burning hours life, 500 V in
built-surge protection,Polycarbonate diffuser, mounting suitable
for E14 / E27 / B22 lamp holders, pf >=
(A) LED Lamps integral type, with PC diffuser suitable LAMP
holder (ii) 5 to 8 watts Cat III
[220] Supplying and erecting LED indoor fittings with LEDs of wattage 6.00 Ea. 427.23
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/aluminium pressure die cast powder coated and
high U.V. & corrosion resistance with diffuser housed in
aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %,CCT 3000 K to
6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency >
85 %( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)(A) Square/ Circular shaped
Surface/Recessed Mount Downlight with provision for spring
loaded mounting clips complete.IP20 (ii) 11-15 watts, Surge-2 KV
[221] Supplying and erecting LED indoor fittings with LEDs of wattage 39.00 Ea. 1794.77
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/aluminium pressure die cast powder coated and
high U.V. & corrosion resistance with diffuser housed in
aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %,CCT 3000 K to
Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 %(
fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)(B) LED Panel Light with provision for
Plane front frame with translucent cover fixed to housing
complete.IP20 (vi) 36 watts, 24" x 24", Surge- 2KV Cat III
[222] (F) Spot Light 425 Lumens, Surge-2KV (i) 3 to 7 Watts Cat III 2.00 Ea. 813.05
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[223] Supplying and erecting LED street light / Flood light fittings with 15.00 Ea. 4997.48
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)(A)
Street Light (IP-65), Surge protection -4KV integral and ,Light must
have 440VAC line supply with over-voltage protection.(ii) above
to 60 watts Cat III
[224] Supplying and erecting LED street light / Flood light fittings with 11.00 Ea. 7266.95
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)(B)
Flood Light (IP-65), Surge protection -4KV integral and ,Light must
have 440VAC line supply with over-voltage protection.(iv) above
90 to 120 watts Cat III
[225] Supplying and erecting LED street light / Flood light fittings with 4.00 Ea. 4092.52
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.) (C)
Post Top Lantern LED fitting comprises of finish cast aluminum
spigot and spun aluminum canopy fixed with opal polycarbonate,
pipe arrangement for vertical mounting driver and accessories
wired upto terminal block.IP 65 (i)20- 30W Cat III
[226] Supplying KITKAT pattern porcelain cut-out fuse with base of 3.00 Ea. 420.16
following current capacity erected on existing block board(vi)
[227] Providing and erecting Approved make Four pole moulded case 3.00 Ea. 6173.12
circuit breaker having breaking capacity ICU of 25 KA. at
V,having normal current rating up to 25 A to 100A. with Fixed
thermal & magnetic release suitable to work on A.C. supply 50 c/s.
with all internal connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing.ICS=100% of ICU only
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[228] Providing and erecting Approved make Four pole moulded case 4.00 Ea. 16221.61
circuit breaker having breaking capacity ICU of 35 KA. at 415 V.
having Normal current rating 200A.with variable Thermal &
magnetic release suitable to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned copper & complete erected
in existing 16 G.M.S.housing ICS=100% of ICU only
[229] Providing and erecting Approved make Earth fault Relay suitable 1.00 Ea. 4983.34
to mount with inter connection suitable to following size of
moulded case circuit breaker having CT ratio & MCCB rating as
following along with shunt trip 220V AC. with all internal
connections & complete erected in existing M.S.housing. (2) 125 A
-200 A , CT Ratio 1/200
[230] Supply of Approved make Iron Clad or metal clad four pole change 1.00 Ea. 1275.63
over switch 415V. confirming to IS of following capacity (B) 32A
[231] Supplying & erecting approved make Four Pole 415V change over 1.00 Ea. 13353.21
switch interior for panel mounting with operating mechanism
A.C.23 duty confirming to IS for (E)250A / 320A cat III
[232] Supplying and erecting triple pole & neutral 440V / 500V panel 1.00 Ea. 1961.42
mounting Copper Busbars with four equal Nos. of electrolyte bus
having current density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable
socket to each bar, erected in existing cubical panel with necessary
connections.(A) Suitable for 100 Amp. Capacity
[233] (B) Suitable for 200 Amp. capacity 2.00 Ea. 3202.71
[234] providing and erecting Miniature circuit breaker single pole 0.5A 26.00 Ea. 270.68
to 2A system and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark
[235] Providing & erecting 240 V MCB double pole switch for lighting 14.00 Ea. 278.76
Load (B Curve) having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity(A) 6 to 32 Amp. Cat
[236] Providing & erecting 415 V MCB Four Pole for Motor & Inductive 4.00 Ea. 668.62
Load (C Curve) having 10KA breaking capacity & confirms to IS
:8828 in existing box having following capacity(b)40 Amp. Cat III
[237] Providing & erecting 415 V MCB Four Pole for Motor & Inductive 10.00 Ea. 737.30
Load (C Curve) having 10KA breaking capacity & confirms to IS
:8828 in existing box having following capacity (c) 63 Amp. Cat III
[238] Providing and erecting Sheet Steel powder coated MCB 4.00 Ea. 3412.79
distribution board - flush / surface mounted fitted with busbar,
neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The
DBs should be used of same company of MCB to be used) suitable
for (B) three phase incoming and single phase horizontal type
outgoing Per phase isolation type (PPI) (b) sheet steel double
door (iii)8 way
[239] Providing and erecting Approved make RCCBs conforming to IS: 12.00 Ea. 1969.50
12640 and having sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on single phase
V,50Hz. having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic component.
for following Max. rating erected as directed (i) 25 Amps.DP Cat
[240] Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 1.50 Ea. 77.77
[241] Providing and erecting Pipe type earthing having 150 cms.long and 15.00 Ea. 368.65
2.5 cms. dia. galvanised iron pipe with coupling and buch buried in
specially prepared earth pit complete with necessary 8 SWG earth
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[242] For using salt and charcoal / coke as required for pipe type 15.00 Ea. 171.70
[243] Supplying & erecting earth pit of minimum bore dia.150mm size 3.00 Nos. 4591.46
approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications with
chamber and heavy duty cover. (A)(approved make OEM has to
submit test certificate including value of earth resistance of
installation duly stamped and signed by agency and officer
Incharge has to ensure the value of earthing resistane mentioned
in test Certificate) & having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing
as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry
form, Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency. (a) For
Electrical Installation up to 440V in normal soilLength of pipe -
[244] Providing & erecting weather proof, dust & vermin proof, floor 2.94 Sq. Mtr 10468.65
mounted front operated indoor type cubical panel board
necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet for
outer body & doors, 16 SWG thick CRC M.S.sheet for internal
partitions with necessary accesories , supporting angles/ flats
channel including cutting, bending, drilling, welding, riveting with
internal partitions & cable alley as per requirements & instruction
of engineer-in-charge with erection of supplied switch gears,
BUSBARS, suitable size of inter connecting PVC copper wire /
copper-aluminium strips, rubber grommets, rib, bakelite control
fuses/MCB for measuring instruments, earth bus & earth bolts,
foundation flange - bolts-base Plates, sufficient nos. of hinged
doors, handles with locking arrangement and rubber gasket,heavy
duty end terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be painted
with epoxy powder coating. (The rates excludes the cost of
switchgears, bus bars, inter connecting mains & Copper Aluminium
strips, meters, Fuses etc. The dimension shall be measured
[245] Providing , erecting , fabricating the M.S. structure as per 250.00 Kg. 77.77
requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections complete with
cutting, welding, grinding & finishing duly painted with one coat of
red oxide with erection on site as per direction of engineer in
charge with necessary grouting, cementing, plastering & finishing
[246] Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 30.00 Mtr 284.82
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following size
of cables (C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
[248] Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable 520.00 Mtr 126.25
multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe of following
size of cables (B) 4 core 6 Sq. mm
[249] Making trench in soft soil of suitable width of 90 cm deep for 80.00 Mtr 55.55
laying cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
[250] Making trench in Hard Murrum / Tar Road of suitable width of 90 40.00 Mtr 74.74
cm or required depth for laying any size of cable or locating the
fault all over the run and back filling the same and making the
surface as normal ground.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[251] Providing & laying approved make Double walled corrugated 455.00 Mtr 62.62
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground / road
surface for enclosing cable (A)50 mm outer dia
[252] Providing & laying approved make Double walled corrugated 125.00 Mtr 95.95
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground / road
surface for enclosing cabl (C))90 mm outer dia
[253] Providing and, fixing heavy duty flange type brass cable gland with 6.00 Ea. 38.38
rubber ring for PVC insulated armoured cable complete with out
going tails, insulating tape etc for following size of cables.
(B) 2 to 4 core 6 Sq. mm
[254] Providing and, fixing heavy duty flange type brass double 3.00 Ea. 75.75
compression type cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails, insulating tape etc
for following size of cables. (B) 3 & 1/2 core 35/50 Sq. mm
[256] Solder less crimping type Aluminium lugs conforming to IS suitable 50.00 Ea. 6.06
for cable of following size evenly crimped with high pressure tool
& connected to switchgear terminals with brass/cadmium plated
nut bolts in an approved manner. (A) 1.5/ 2.5/4/6 Sq.mm
[259] Solder less crimping type Copper lugs conforming to IS suitable for 200.00 Ea. 8.08
cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. (A) 1.5/2.5 to 6 Sq.mm
[260] Supply, Installation, Testing and Commissioning of suitable sweep, 74.00 Ea. 2629.03
BEE 5 Star rated, Ceiling fan with Brush Less Direct Current (BLDC)
permanent ferrite magnet Motor, class of insulation: B, Rust free
nos.Aluminium blades, 2 nos. canopies, shackle kit with earthing
provision, copper winding, Power factor not < 0.9, Service Value
(CMM/W) minimum 6.85, Air delivery minimum 215 CMM,
RPM,230v (tolerance as per IS : 374-2019), THD < 10%, compitible
with electronic regulator unit for Speed Control and all remaining
accessories including safety pin, nut bolts, washers, temperature
rise = 75 degree C (Max.), suitable for 140 to 285 Voltage and
rectifier circuit with surge, over current and overload protection
50 Hz, Single phase AC Supply, earthing etc. Complete as
required.[ Make shall be approved by Engineer in Charge] (A)
[261] Supplying and erecting 19 / 20 mm. nominal bore Medium Class 74.00 Mtrs 108.07
M.S. Pipe down rod erected duly painted for fan complete with
proper insulation without leckage and earthing.
[262] Providing 2.5mm.thick laminated acrylic sheet to cover the fan 74.00 Ea. 18.18
hook or Fan box.
[263] Supplying & erecting approved make low noise decorative exhaust 20.00 Ea. 1703.87
fan having square frame ABS body with inbuilt lowers & square
frame.200mm with 1350RPM Cat.II
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[264] Supplying and erecting approved make Octagonal pole made from 15.00 Ea. 8192.11
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable
foundation (Included) as per details given by manufacturer
considering site requirement.(D) 6 Mtr. Long 70 mm Top X
mm bottom dia, 3 mm thickness with 200mmX200mmX12mm
base plate, 4-M20 Bolts and 600mm long with necessary G.I. J
Bolts .Approx Pole weight 59 kg
[265] Supplying & erecting approved make SMC press moulded 11.00 Ea. 476.72
composite FRP. loop-in, loop-out approx. 2mm thick box complete
with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting
mob & hinged doors as per requirement having locking
arrangements with mounting clamp with nuts, bolts & washers
suitable for erection on pole with cable clamps& earth bolt of
following size of box.(C)150mm x 125mm x 100mm [deep]
[266] Providing and erecting street light pole bracket comprising main B 15.00 Ea. 614.08
Class GI pipe of 4.2 cm/require outside dia. complete with suitable
B Class G.I sleeve tubing of approx. 45cms.length and suitable for
76.5 mm / 80mm. / require size pole top having sufficient
fasteners for fixing the brackets and having spread of 1 mtr. length
with suitable rise as per site condition & suitable welded stiffener
reducer and nipple with check nut complete painted with one coat
of Red oxide / PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms.[A] Single Arm bracket
[267] Supplying and erecting B class Galvanized iron pipe having smooth 22.00 Mtr 215.13
finished bore of the pipe on both ends erected nuts and bolts
along the pole / wall shaping the pipe as per site requirement.
Pipe dia as following. (B) 32 mm dia
[268] Supplying & erecting IP 55 grade following size section pillar 1.00 Ea. 3595.60
fabricated from joint less M.S. Sheet with angle iron legs made
from jointless M.S. Angle with cable clamps to be buried in ground
to have appropriate erection to work uniform until erected with
cement concrete foundation and 45 cm high bricks work finishing
with plaster etc. hinged double door internally supported on both
side, with internal and outside looking arrangement with look and
keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos. one is
welded and other with nut and bolt for erecting Bakelite sheet.
Painting the Section Pillar inside and out side with three tank
powder coated paint. section pillar roof should be without joint
with water leakage proof & tested as per IP 55 test & followed by
IS 2147 of 1962 (B) 75 X 60 X 45 cm section pillar fabricated from
16 Gauge MS Sheet with angle iron legs 45 cm long made from
X 35 X 5 mm thick MS angle.
[269] Supplying and erecting nuwood 12 mm thick on existing angle iron 1.00 Sq.Mtr. 291.89
[270] Supplying & erecting approved make time switch with single pole 1.00 Ea. 2354.31
air break contacts suitable for 230 V.15/16A.complete with self
starting motor driven clock ‘ON’ &’ OFF’ automatic arrangement at
any predetermined time during each 24 hours,With nickel
cadmium rechargeable battery backup erected as directed.
[271] Supplying & erecting power contactor ,AC3 duty for time switch 1.00 Ea. 857.49
complete erected as per direction Cat III (C) 4 pole 440V 16 Amp.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[272] Providing and erecting approved make split air-conditioning unit 3.00 Ea. 59293.06
consisting of copper condensing unit with fan motor, hermetically
sealed rotary compressor with accessories etc. duly connected
separately erected evaporating unit and blower motor with its
accessories by means of extra supplied proper insulated copper
tubing,drain PVC pipes suitable for ( cost includes powder coated
Stand, Eco Friendly green gas charging, 15A plug top & Remote
Control) with necessary core cutting.(1)For ISEER Range
(KWH/KWH)(3.1 to 3.99) Premium Category(c) for 1.7 to 2.0 ton
[273] Supplying and erecting insulated pair of soft copper tubing open or 24.00 Rnmtr. 965.56
concealed including power and control cable,necessary PVC drain
pipes for Split AC machine up to 4 TR capacity
[274] Providing & erecting water cooler having storage capacity 150 Ltr. 2.00 Ea. 55893.40
& cooling capacity 150 Ltr.per hour @ an ambient temp of 45˚ C.
The outlet temp. of the water should drop by 15˚C within a hour,
The water cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank surrounded
by evaporating, coil, thermostats, relay etc.complete with
necessary inlet & outlet connection. The body of water cooler will
be made from Stainless Steel.
[275] Supplying & erecting 5 stage single reverse osmosis water 2.00 Ea. 29187.99
purification system with M.S. powder coated frame, prefilter
housing with 'O' ring presediment filter GAC filter, carbon filter
suitable buster DC pump capacity 80 psi, mention with 40 psi
inline type post carbon filter auto low & high pressure switches
with following size of storage tank & LPH capacity & erected as
directed [C] 50 Ltr / Hr with 150 psi 2 nos booster pump
[276] Supply and Erecting of Static Stabilizer suitable for following 3.00 Ea. 4029.90
capacity of A.C Machine the Stabilizer Must have Minimum
Technical Specification are Input working Single Phase Voltage
Range Up to 150V-280V.50Hz, Output Voltage Range Up to 200V-
240V,50Hz,Autoreset Facility,LED Display for Indicating
Voltage,Spike/Surge Protection,Time Delay Facility,Proper Wall
Mount Facility with Required Accessries & on site 3 year
Replacement/Repairing Warranty.(2) For 2 Ton Thermal Overload
Protection 15 Amp.
[277] Supplying and erecting approved make panel mounting type 3.00 Ea. 1275.63
Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts
range erected on existing panel board with all connection, wiring
etc .with manufacturers calibration certificate.
[278] Supplying and erecting approved make panel mounting type 3.00 Ea. 1558.43
Digital Ammeter having 3 digits LED display, external CT
operated, calibrated for 0 to 1000 Amps suitable to operate on
500 Volt AC , erected on existing panel board with all connection,
wiring etc .with manufacturers calibration certificate.
[279] Supplying and erecting approved make Analog type moving iron 9.00 Ea. 1584.69
C.T operated Ammeter A C Current suitable slide in scale 0-
Amp. with 3 Nos. of Current Transformer erected on panel board
with connections.
[280] Supplying and erecting Ammeter / Voltmeter selector switch for 3 6.00 Ea. 317.14
phase AC Supply 500 V on existing panel board with necessary
[281] Supplying and erecting approved make suitable panel indicator 9.00 Ea. 43.43
LED type lamp, lens cover, complete erected with necessary
[282] Providing & erecting open well horizontal mono block pump set 2.00 Ea. 15707.52
with cast iron body, complete for three phase submersible motor
having [C] For 3 HP 3 phase open well horizontal mono block
pump set suitable for 85 LPM to 270 LPM @ 11 mtr to 33 mtr
head suitable for 50/65 mm dia delivery pipe Cat II
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[283] Supplying & erecting approved make motor control cubical panel 2.00 Ea. 7250.79
[Star delta] made from 16G CRCA sheet duly epoxy powder
painted inside and outside with hinged doors and locking with
suitable size of ON - OFF isolator (AC 3 / 23 duty) main fuses.
Digital volt and current meter (in a single unit) with micro
controller based control unit and current sensing single phasing
preventer electronic overload protection, over voltage
(Programmable) protection and under voltage (Programmable)
protection, prod less dry run protection programming facility for
setting of all parameter like overload current, high voltage limit,
low voltage limit, dry run limit with digital indication on seven
segment LED display for any fault like over load, high voltage, low
voltage, dry running single crimped, electronic star delta timer,
feather touch start / stop push buttons to be erected on angle iron
frame. Grouted on wall the contactors will be of L& T, Siemens,
BCH make only) (A) DOL up to 5.0 H.P.
[284] Lowering of submersible motor pump set at the depth of following 2.00 Per Job 856.48
,complete with required. Nos. and size of casing pipes erected by
means of proper chain pulley block & pipe wrenches after
checking of threads of each pipe with coupling to take the load of
the pump set and pipe assembly filled up with water (D)For Open
well Horizontal submersible pump set for sump well
[285] Providing and erecting ISI marked PVC insulated PVC Sheathed 50.00 MTR 104.03
Flat flexible Submersible copper cable approved make of
following Size. (B) 3 Core x 2.5 Sq. mm.
Four CroreEleven Lakh Fourty Five Thousand Two Hundread Four Rupees andSixty Six Paisa Only
I/We am/are willing to carry out the work at…………………………………………….% above/below percent (Should be written in figures and words)
of the estimated rate mentioned above. Amount of my / our tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct…………………………% below Add…………………………% Above
In Worlds In Worlds
(* Please strike out whichever is not applicable).
1. The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which
no extra payment shall be made.
2. The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3. GST and Income tax TDS will be deducted at a source while making payments of bills
4. In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement
Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design
the cost of difference of cement consumption have been deducted from the rate of original item at the rate of input rate
mentioned in all the tender.
5. Credit of dismantled materials of amount of Rs. 0.00/- must be recovered from contractor's 1st R.A. bill.
6. All duties, taxes, and other levies except GST payable by the contractor under the contract, or for any other cause shall be included
in the rates, prices and total Bid Price submitted by the Bidder. (GST will be paid extra)
Dated Signature of Dy. Executive Engineer Executive Engineer
the Contractor. Panchayat (R&B) Sub Division Panchayat (R&B) Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
8.GR SBD.pdf
9.Envirement MMGSY.pdf
1. SBD_Amreli Taluka Panchayat.pdf
2a. Specification Index.pdf
2b. BUILDING WORK BOOKLET.pdf
2c. Electrical Specification.pdf
2d. Detail Civil Specification.pdf
2e. SBD WTIH ELE BOOKLET FOR CIVIL JOINT 6.pdf
2f. make list FINAL -3.pdf
2g. Sub Cond. -5 Electrical.pdf
2h. Special Condition for Fire Work.pdf
3. BOQ.pdf
4. Building GR.pdf
5. Testing Schedule.pdf
6. NPT.pdf
0.4 Tender Notice No.1.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .