Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC HOUSE NO RA 288 GANDHI CHOWK SADAR BAZAR KARNAL HARYANA 132001 | KARNAL | HARYANA | 132001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹3.6 L+₹21,918 (6.58%)Rejected-Finance RAILWAY ROAD 9 10 KC MARKET 132001 2021R66 | KARNAL | HARYANA | 132001 | L2 | Rejected-Finance Highest | |
| 3 | L3₹4.0 L+₹67,360 (20.2%)Rejected-Finance VILLAGE DHAND KAITHAL 136020 R24 | KAITHAL | KAITHAL | HARYANA | 136020 | L3 | Rejected-Finance Highest | |
| 4 | L4₹4.1 L+₹72,374 (21.7%)Rejected-Finance 790 STREET NO 1 PATEL NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L4 | Rejected-Finance Highest | |
| 5 | L5₹4.1 L+₹77,529 (23.3%)Rejected-Finance 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | L5 | Rejected-Finance Highest |
Tender Value
₹4.7 L
EMD Value
₹9,460
Closing Date
14 Nov 2023, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Renovation of Nabhi Kamal in Distt. Kurukshetra (Pdg. High Mast Tower ).
2023_HRY_327093_1
202382396FC9 F50C 4CA0 8D15 C41F13DF7BCC663BAR
Open Tender
Civil Works
Works
300 days
Ambala Cantt
Renovation of Nabhi Kamal in Distt. Kurukshetra (Pdg. High Mast Tower).
2 documents required · 2 mandatory
₹500
₹9,460
Yes
27 Dec 2023
7 Nov 2023
15 Nov 2023
8 Nov 2023
14 Nov 2023
8 Nov 2023
Amount
[2.B1145] B1145. G.I. pipes 50 mm dia
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP
[23.23.1.3]MISCELLANEOUS 1.3. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 25 mm dia
[23.27.1]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 1. M.S. pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in 1:2:4 cement concrete block of size 750 mm x 450 mm x 200 mm above ground level , having a base of size 900 mm x 600 mm x 250 mm below ground level. 0 0
[23.5.6.2]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.2.4.2]LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core
[24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core
[24.4.15.2]STREET LIGHT 15.2. B.S.E.N. 10025 High Masts "Supply, installation, testing and commissioning of 16 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 9/12 nos. luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer -in-Charge Thickness of Top and Bottom Section = 3 mm & 4mm (minimum) Top Dia = 150 mm and Bottom Dia = 410mm Thickness of Galvanization - Top = 65 micron (minimum) and Bottom = 85 micron (minimum)"
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
[24.9.2]RCC FOUNDATIONS FOR HIGH MAST OCTAGONAL POLES 2. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 16m high mast pole
`Supply of 16 Sqmm 4 Core Armd cable, LT Power Cables - Aluminium Conductor HAVELLS BRAND Power Cables, Solid Aluminum Conductor up to 10 sq. mm and Balance Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed complete in all respect upto the entire satisfaction of Engineer-in- charge (Make : Havells, Polycab, Grandlay, KEI ). `
`Supply and erection of LED Flood light 250 watt of Makes Hevells (JETA IRIS MAX) and model No. JETAIRISMAXFL250WLED757PWBLTG Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting and accessories required to complete the job in all respect including erection on existing pole for fixing including connection of the same upto the entire satisfaction of Engineer in Charge of the work Crompton / Surya / Orient ). ` .
`Cost of cutting of metal road and repairing, filling etc. including all labour charges with petty materials complete in all respect upto the entire satisfaction of Engineer-in-charge of the work. `
`Supply and erection of 63 Amp. 3 Pole/230V Astronomical automatic time switch of Havells make alongwith contactor of required capacity movement controlled by precisaty quartz osciliation operation on main supply of continue to run on built in rechargeable nickel cadium cell for 150 hours in the event of power failure including cost of contractor complete in all respect upto the entire satisfaction of Engineer-in-charge of the work ( Equivalent make Havells / CandS / LNT ).`
POMERA AND CO LTD
MS Tiger Solar Light Trading Co.
Dhamija Power Constructions
J.B.S.Electrical Co.
Som Nath Contractor
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .