Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹36.3 LAccepted-AOC | L-1 | Accepted-AOC lowest | |
| 2 | L-2₹37.8 L+₹30,030.77 (0.80%)Rejected-Finance | L-2 | Rejected-Finance other than lowest | |
| 3 | L-3₹42.0 L+₹4.5 L (11.9%)Rejected-Finance | L-3 | Rejected-Finance other than lowest | |
| 4 | L4₹42.3 L+₹4.8 L (12.9%)Rejected-Finance | L4 | Rejected-Finance other than lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
13 Aug 2021, 6:00 pmClosed
GE 969 EWS
GE 969 EWS
PROVISION OF CERTAIN SANCATION WORK,SPECIAL REPAIR,MINOR WORKAT BARAMULLA UNDER GE 969 EWS.
2021_MES_460819_1
CANO 969/WS- /2021-22
Open Tender
Civil Works
Item Rate
270 days
Baramulla
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 969 EWS
₹80,000
Yes
17 Jan 2022
17 Jul 2021
14 Aug 2021
17 Jul 2021
13 Aug 2021
31 Jul 2021
Amount
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed by engineer-in-charge.
S&F pre-painted galvalume aluminium zinc coating GI based Corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by engineer-in-charge.
S&F pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by engineer-in-charge.
Dismantling framed timber scantlings 40 sq. cm & over in section, in any position complete all as specified and directed by engineer-in-charge.
S&F second class wrought hard wood in scantling in timber fixed complete all as specified and directed by engineer-in-charge.
M&L Preparing surface of wood & wood based materials, steel & iron work, new or old, of any description & girth, not otherwise described, & treated with tar or coal tar black paint complete all as specified and directed by engineer-in-charge.
M&L IInd class softwood weather boarding, clean sawn, plain 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps complete all as specified and directed by engineer-in-charge.
Dismantling framed timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position complete all as specified and directed by engineer-in-charge.
M&L IInd class soft wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads exc 13 & nexc 25 sqcm complete all as specified and directed by engineer-in-charge.
Taking down Chowkats or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specified and directed by engineer-in-charge.
S&F IInd class Hardwood 35mm thick panellled shutters (any numbers of panels) with panels of timber flat on both sides (feather edged) or of veneered complete all as specified and directed by engineer-in-charge.
S&F Aluminium, anodised, barrel tower bolts 200mm long of extruded section complete all as specified and directed by engineer-in-charge.
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by engineer-in-charge.
S&F Aluminium handles 150mm size, cast type, anodised complete all as specified and directed by engineer-in-charge.
S&F Butt hinges 100mm size, medium weight, cold rolled mild steel complete all as specified and directed by engineer-in-charge.
Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed by engineer-in-charge.
S&F 2nd class soft wood 30mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut & mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); to chowkats complete all as specified and directed by engineer-in-charge.
S&F Butt hinges 50mm size, medium weight, cold rolled mild steel complete all as specified and directed by engineer-in-charge.
S&F Aluminium, anodised, barrel tower bolts 100mm long of extruded section complete all as specified and directed by engineer-in-charge.
S&F Aluminium handles 100mm size, cast type, anodised complete all as specified and directed by engineer-in-charge.
S&F Sheet glass 4.0mm thick, ordinary quality & glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed by engineer-in-charge.
M&L for Applying two coats of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of pink primer complete all as specified and directed by engineer-in-charge.
Demolition of PCC,Tiles in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed by engineer-in-charge.
M&L 100mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in sub base of flooring complete all as specified and directed by engineer-in-charge.
M&L 25mm thick PCC type B-0, (1:2:4) using 12.5mm graded stone aggregate as in sub base of tiling complete all as specified and directed by engineer-in-charge.
S&F light shade Vetrified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:6) complete all as specified and directed by engineer-in-charge.
M&L for Applying two coats of cement base paint, white or tinted on new weather board surface including preparation of surface complete all as specified and directed by engineer-in-charge.
M&L fore Applying two coats of cement base paint, white or tinted on old weather board surface including preparation of surface.
Dismantling boarding of any descrption fixed in any position with nails including cover fillets. Complete all as specified and directed complete all as specified and directed by engineer-in-charge.
S&F for 4 mm thick veneered decorative plywood grade 1 (with BWR resin) with decorative face veneers on one face fixed with nails to timber frame work in ceiling incl corner bedding complete all as specified and directed by engineer-in-charge.
S&F for 4 mm thick veneered decorative plywood grade 1 (with BWR resin) with decorative face veneers on one face fixed with nails to timber frame work in wall incl corner bedding complete all as specified and directed by engineer-in-charge.
M&L for LLDPE rotational moulded polythene septic tank in 3 chambered design for 08 users including excavation in any type of soil, installation of vent shaft, provision of opening for inlet & outlet SGSW pipes, PCC 1:4:8 at base of excavated area. Complete all as specified and directed by Engr-in-charge.
M&L soakage well 1.20m dia and 1.50 m depth excavation in any type of soil, foundationin PCC 1:3:6, wall of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screed chamber made of brick masonary inCM, RCC cover slabin M-25/SFRC cover, interconnecting pipesof RCC/DWC. Complete fillled with brick bats of size. (Note: (i) Incl excavation, retrning filling and removal of earth work. Complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exc 1.5m wide and not exc 1.5 mtr deep for sewage pipe line and manhole etc and getting out in soft/loose soil complete all as specified and directed by engineer-in-charge.
M&L for cement concrete 1:4:8 type D2 using 40mm graded aggregate as in foundation complete all as specified and directed by engineer-in-charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed by engineer-in-charge.
M&L rendering 15mm thick on fair faces of brick work in CM 1:4 on internal surfaces complete all as specified and directed by engineer-in-charge.
M&L for rendering 15mm thick on other than fair faces of brick work in CM 1:6 on external surfaces of wall finished even and smooth complete all as specified and directed by engineer-in-charge.
M&L PCC 1:3:6 type C2 as in channel and benching of manholes complete all as specified and directed by engineer-in-charge.
M&L for cement concrete 1:3:6 type C2 in bed to pipe incl packing under and haunching against the pipes 150mm internal dia after the pipes are laid jointed and tested complete all as specified and directed by engineer-in-charge.
M&L 150MM dia Salt-glazed stoneware drain pipes laid in trenches and jointed as specified complete all as specified and directed by engineer-in-charge.
M&L RCC 1:2:4 type B1 using 20mm draded aggregate pre-cast cover slab for manhole set in cm 1:6 complete all as specified and directed by engineer-in-charge.
M&L mild steel TMT bars 08 mm dia and over, cut to length bent ot shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Removal of excavated material nexc 50m and depositiong where directed at a level nexc 1.5m above the starting point.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil.
M&L Precast cement concrete type C1 (1:3:6) using 20 mm graded aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in CM(1:4) with joints to match complete all as specified and directed by engineer-in-charge.
Removing shrubs, bushes etc and area cleaning around wall and reservoir etc complete all as specified and directed by engineer-in-charge.
M&L for dewatering the SWTs completely to make dry and cleaning of SWTs removisng sludge in semi solid state or liquid state by manually or by pressure pump including pump and removal of sludge if any to a distance exc 1.5KM but nexc 5KM out of MOD land. complete all as specified and directed by engineer-in-charge.
Taking down of cement plaster of any description on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed by engineer-in-charge.
M&L 20mm thick cement plaster 1:4 on fair faces of brick work/stone masonary/concrete surface complete all as specified and directed by engineer-in-charge.
M&L for applying on new concrete or plastered surfaces to one coat of CW 100 G (tank waterproof coating) allow curing for 72 hrs. Thereafter to applying three coats of epoxy slurry mortar heavy duty tank coating at interval of 4-6 hrs between each coat. MAKE- ASIAN PAINT, DR FIXIT, CHEMISTIC, PIDILITE, BERGER
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by engineer-in-charge.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed by engineer-in-charge.
M&L for Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and directed by engineer-in-charge.
Demolition of cement concrete in ground floor or pavings nexc 15cm thick below or above ground level. complete all as specified and directed by engineer-in-charge.
M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth protection including joints with filler bitumen and sand complete all as specified and directed by engineer-in-charge.
M&L for floor slab to fill all visible cracks joints etc with conjoint-50 (Polymeric joint sealeant) by first primer with chemistik primer 10,thereafter to provide and apply one bond coat of EP TAC 404 (Epoxy Tac Coat) prior to laying M-15 concrete in 75mm thickness laid to level to finish. MAKE- ASIAN PAINT, DR FIXIT, CHEMISTIC, PIDILITE, BERGER
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.(a) One light point/fan point/ex fan point controlled by one 5 Amps switch one way
(b) One 3 pin 5 Amp switch socket outlet on independent board
(b) One 3 pin 5 Amp switch socket outlet on same board
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor.
S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed. Note : Taking down of swithches included in taking down point wiring
S&F Switch socket combination 2 in1, 3 pin,5Amp flush type,universsal multi purpose 5 Amp complete all as specified and directed by engineer-in-charge.
S&F Switch socket combination 2 in1, 3 pin, 15Amp flush type,universsal multi purpose 5 Amp complete all as specified and directed by engineer-in-charge.
Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body complete all as specified and directed by engineer-in-charge.
S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 16 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
S&F in replacement of MCB 63 Amp TPN 10KA, 50 HZ, 240 V 'C' series complete all as specified and as directed by Engineer In Charge.
S&F in replacement of MCB SPN 20Amp 10KA, 50 HZ, 240 V 'C' series complete all as specified and as directed by Engineer In Charge.
S&F in replacement of MCB SP 6 to 32 Amp 10KA, 50 HZ, 240 V 'C' series complete all as specified and as directed by Engineer In Charge.
M&L for Sub main wiring with 2 runs of 6 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC casing capping of required size with accessories along with 1 run of 6 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring complete all as specified and as directed. Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth along with PVC conduit will be measured as one length.
Supply and lay cable XLPE insulated screened PVC bedded , galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core complete all as specified and as directed by Engineer In Charge.
S&F high 18 watt effieiency LED aluminium liner batten complete all as specified and as directed by Engineer In Charge.
Supply,laying and testing cable XLPE insulated screened PVC bedded , galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core complete all as specified and as directed by Engineer In Charge.
Supply,laying and testing cable XLPE insulated screened PVC bedded , galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 3.5Core complete all as specified and as directed by Engineer In Charge.
Supply and filling dry river sand in trenches including spreading for cushioning of LT UG cablec and punning down complete all as speified and directed by Engr-in-charge. Note : Punned down thickness shall be measured and paid
M&L for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as speified and directed by Engr-in-charge.
M&L for earthing with galvanised iron earth plate electrode 600mm x600mmx 6mm thick burried directly in ground (Eart pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.00mm dia connected to earth plate electrode by means of bolts,nuts,check nutsand washers,earth wire protected with and including 15 mm bore light grade ISI marked GI pipe upto 7.5 meters long aii as shown in electrical plate no 5 of MES schedule part-1,with and includingPCC 1:2:4 type B1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqmtrwith handle andangle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked,GI fannel with GI mesh,filling with mixture of commen salt and charcoal,necessary excavation, refilling, removing away spoiland earth work in any type of soil,including test point, testing and commissioning complete all as specified and directed.
Supply & Fixing 1 X 22 Watt surface and wall mounted LED batten, with polycarbonate housing & integrated electronic dirver complete all as specified and directed by Engineer-In-Charge.
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed by Engineer-In-Charge.
S&F GI Tubes 80mm, `light grade', galvanised, with all fitting; laid in trenches or laid under floor,fixed on wall with providing clamps etc complete all as specified and directed by engineer-in-charge.
S&F Sluice Valve 80 mm Class PN 1.6 both end flanged complete with iron wheel complete all as specified and directed by engineer-in-charge.
S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by engineer-in-charge.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm, 3 core, 1100 Volts grade complete all as specified and directed by engineer-in-charge.
S&F GI pipe, bracket for street light fittings made out of 32/40 mm dia GI Pipe light grade 1.2m long bent to required angle/shappe with and including necessary clamps of 03 sets necessary nuts, bolts & washers of suitable size and painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by engineer-in-charge.
M/S ESS EMM ENTERPRISES
M/S HAJI MOHD ASHRAF SUMJI
M/S IQ ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .