Loading…
Loading…
Tender Value
₹5.2 Cr
EMD Value
₹10.4 L
Closing Date
4 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TRD
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V or V/N crore, whichever is less; were V= Advertised value of the tender in crore of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
Similar nature work:Tenderer should have experience on"Execution of any 1500V DC or 25kV AC OHE work."(Authority: GM/Elect/WR/CCG's letter No. EL/90/TRD/W/1 dated 21.01.2009)
Tenderer has to submit attested copy of valid electrical contractor's license, which can be in his own name or in the name of his firm issued by any as per Clause 31 of compilation of Regulation of CEA2023 or as amended from time to time. They shall keep valid license throughout the period of execution of work by getting it renewed at suitable intervals and submit an attested copy of the same to the Railways.
The tenderer must have successfully completed or substantially completedany one of the following categories of work(s) during last 07 (seven) years,ending last day of month previous to the one in which tender is invited:(i) Three similar works each costing not less than the amount equal to 30% ofadvertised value of the tender, or(ii) Two similar works each costing not less than the amount equal to 40% ofadvertised value of the tender, or(iii) One similar work costing not less than the amount equal to 60% of advertisedvalue of the tender.
10 conditions · 9 needing a document upload
Please submit your bank details i.e. Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, PAN Number, Mobile Number and e-mail address
At the time of submission of bid, if you have any special Condition then upload in scanned pdf copy.
Please furnish list of personal, organization available on hand and proposed to be engaged for the subject work.
Please furnish list of plant and Machinery available on hand own and proposed to be inducted own and hired to be given separately for the subject work.
Please furnish list of Works completed in last Seven years (Ending last day of month previous to the one in which tender is invited) giving Description of Work, Organization for whom executed, approximate value of contract at time of award, Date of award and Date of Completion. Date of actual Start, Actual Completion and Final value of Contract shall also be given.
Please furnish list of works on hand indicating description of works, contract value, Approximate value of balance work yet to be done and date of award.
Tenderer has to submit attested copy of valid electrical contractor's license, which can be in his own name or in the name of his firm issued by any as per Clause 31 of compilation of Regulation of CEA2023 or as amended from time to time. They shall keep valid license throughout the period of execution of work by getting it renewed at suitable intervals and submit an attested copy of the same to the Railways.
The tenderer whether sole proprietor/ a company or a partnership firm / joint venture (JV) / registered society / registered trust/HUF/ LLP etc. if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person specifically authorizing him/them to sign the tender, submit the tender, and further to deal with the Tender/Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed/ Memorandum of understanding/ Article of Association/ Board resolution, failing which tender shall be summarily rejected.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer has to submit attested copy of valid electrical contractor's license, which can be in his own name or in the name of his firm issued by any as per Clause 31 of compilation of Regulation of CEA2023 or as amended from time to time. They shall keep valid license throughout the period of execution of work by getting it renewed at suitable intervals and submit an attested copy of the same to the Railways.
OHE modification work in connection with Improving bad layout ofcross overs 103- 104, 113-115, 113-117, 136-140, 137-138 & providing simultaneous reception facility at Wankaner Yard.
DRM-RJT-EL-TRD-2026-27-21~WR
DRM-RJT-EL-TRD-2026-27-21
Open
Works - General
9 Months
Rajkot, Gujarat
₹0
₹10.4 L
10 Aug 2026
10 Aug 2026
21 Aug 2026
141 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 5,21,30,575.11 | ||
| — | 10.00 | — | — | ||
| Survey, Design and preparation of OHE layoutplan and SED as per technical specifications | — | — | — | 1,80,519.5 | |
| — | 250.00 | — | — | ||
| Preparation of SWR diagram board along withcaption diagram as per explanatory notes | — | — | — | 83,430 | |
| — | 125.00 | — | — | ||
| Supply of fabricated galvanised steel structureand SPS as per technical specifications | — | — | — | 1,81,90,087.5 | |
| — | 125.00 | — | — | ||
| Erection of fabricated galvanised steel structureand SPS as per explanatory notes | — | — | — | 16,46,102.5 | |
| — | 500.00 | — | — | ||
| Concrete for foundation and plinth in all types ofsoil incl. hard/ rocky soil (incl. excavation andsupply of materials viz. cement, sand and ballast) | — | — | — | 38,90,135 | |
| — | 130.00 | — | — | ||
| Supply of Single cantilever assembly completewith insulator as per technical specifications. | — | — | — | 35,62,348.4 | |
| — | 130.00 | — | — | ||
| Erection of cantilever/Bracket assemblycomplete with insulators as per explanatory notes | — | — | — | 4,07,375.8 | |
| — | 15.00 | — | — | ||
| Supply of regulating equipment 3 pulley typecomplete with allaccessories as per technical specifications | — | — | — | 9,31,751.25 | |
| — | 15.00 | — | — | ||
| Erection of Regulating equipment 3 pulley typecomplete with all accessories as per technicalspecifications and explanatory notes. | — | — | — | 2,15,016.15 | |
| — | 150.00 | — | — | ||
| Supply of new droppers complete with clips etcfor the new span for modification and shifting ofOHE to new structure/cantilever as per technicalspecifications | — | — | — | 7,57,716 | |
| — | 120.00 | — | — | ||
| Modification and shifting of OHE to newstructure, removal of olddroppers and erection of new droppers as perexplanatory notes. | — | — | — | 7,35,142.8 | |
| — | 8.00 | — | — | ||
| Supply of section insulator assembly includingcore and cut in insulator as per technicalspecifications | — | — | — | 5,20,667.68 | |
| — | 8.00 | — | — | ||
| Erection of Section insulator assembly includingcore and cut ininsulator as per explanatory notes | — | — | — | 61,216 | |
| — | 10.00 | — | — | ||
| Supply of material for termination of Singleconductor (including supply of 9 ton cut ininsulator) as per technical specifications | — | — | — | 85,941.8 | |
| — | 10.00 | — | — | ||
| Erection of material for termination of Single conductor (including supply of 9 ton cut ininsulator) as per explanatory notes | — | — | — | 18,357.6 | |
| — | 15.00 | — | — | ||
| Supply of material for termination of Doubleconductor (including supply of 9 ton cut ininsulator) as per technical specifications | — | — | — | 2,26,891.05 | |
| — | 15.00 | — | — | ||
| Erection of material for termination of Doubleconductor (including supply of 9 ton cut ininsulator) as per explanatory notes | — | — | — | 34,418.1 | |
| — | 25.00 | — | — | ||
| Supply of Guy Rod assembly complete as pertechnical specification for high rise OHE | — | — | — | 2,85,015 | |
| — | 25.00 | — | — | ||
| Erection of Guy Rod assembly complete as perexplanatory notes for high rise OHE | — | — | — | 56,028.75 | |
| — | 50.00 | — | — | ||
| Supply of 9 ton cut in insulator as per technicalspecifications. | — | — | — | 3,65,617.5 | |
| — | 50.00 | — | — | ||
| Erection of 9 tonne cut in insulator as perexplanatory notes. | — | — | — | 54,705 | |
| — | 30.00 | — | — | ||
| Supply of Post/Support insulator as per technicalspecifications | — | — | — | 3,27,418.2 | |
| — | 30.00 | — | — | ||
| Erection of 25 KV post/Support insulator as pertechnical specifications and explanatory notes. | — | — | — | 39,012.9 | |
| — | 500.00 | — | — | ||
| Supply of various types of jumpers with fittingsas per technical specifications | — | — | — | 13,46,335 | |
| — | 6.00 | — | — | ||
| Supply of 25 KV single pole isolator completewith/without earth heel and jumperingarrangement as per technical specifications. | — | — | — | 5,99,285.52 | |
| — | 6.00 | — | — | ||
| Erection of 25 KV single pole isolator completewith/without earth heel and jumperingarrangement as per explanatory notes | — | — | — | 34,562.16 | |
| — | 5.00 | — | — | ||
| Supply of anti-creep arrangement as pertechnical specifications | — | — | — | 2,11,054.6 | |
| — | 5.00 | — | — | ||
| Erection of anti-creep arrangement as perexplanatory notes | — | — | — | 29,342.3 | |
| — | 1.00 | — | — | ||
| Erection of overhead equipment includingcatenary, contact, jumper and dropper wires,fixing of number plates and various types ofboard as per explanatory notes | — | — | — | 80,467.08 | |
| — | 5000.00 | — | — | ||
| Supply of all types of galvanized bonds as pertechnical specifications | — | — | — | 16,48,300 | |
| — | 5000.00 | — | — | ||
| Erection of all types of galvanized bonds as perexplanatory notes | — | — | — | 3,00,200 | |
| — | 50.00 | — | — | ||
| Supply of different types of caution boards asper technical specifications | — | — | — | 67,804.5 | |
| — | 200.00 | — | — | ||
| Supply of retro reflective number plates as pertechnical specifications | — | — | — | 1,76,382 | |
| — | 200.00 | — | — | ||
| Erection of retro reflective number plates as pertechnical specifications | — | — | — | 19,232 | |
| — | 15.00 | — | — | ||
| Supply of Earthing stations as per technicalspecifications | — | — | — | 73,029.6 | |
| — | 15.00 | — | — | ||
| Erection of Earthing stations as per explanatorynotes | — | — | — | 25,620.9 | |
| — | 60.00 | — | — | ||
| Dismantling of mast, portal, TTC & other smallpart steel as per explanatory notes | — | — | — | 5,60,465.4 | |
| — | 12.00 | — | — | ||
| Dismantling and removal of Guy rod assemblyand terminations as per explanatory note | — | — | — | 15,958.2 | |
| — | 200.00 | — | — | ||
| Breaking of Concrete/ foundation/PCC/ Hardrock of Mast, Portal and TTC as per explanatorynotes | — | — | — | 8,02,848 | |
| — | 5.00 | — | — | ||
| Supply of materials for splicing and extension ofanchors OHE as per technical specifications | — | — | — | 68,682.5 | |
| — | 5.00 | — | — | ||
| Erection of materials for splicing and extensionof anchors OHE as per explanatory notes. | — | — | — | 42,613.55 | |
| — | 10.00 | — | — | ||
| Dismantling of regulating equipment as perexplanatory notes | — | — | — | 84,152.1 | |
| — | 5.00 | — | — | ||
| Dismantling of Single pole isolator withcomplete assembly as per explanatory notes | — | — | — | 22,701.35 | |
| — | 60.00 | — | — | ||
| Dismantling of Cantilevers as per explanatorynotes | — | — | — | 94,770 | |
| — | 500.00 | — | — | ||
| Supply of 130 Sq.mm copper large span wire fortermination as per technical specifications. | — | — | — | 5,41,825 | |
| — | 70.00 | — | — | ||
| Transportation of material from Railway depot towork site or released material from work site torailway depot | — | — | — | 3,18,415.3 | |
| — | 220.00 | Each Span | — | ||
| Tower wagon checking and adjustment of OHEas per technical specifications | — | — | — | 6,07,714.8 | |
| — | 500.00 | — | — | ||
| Supply of contact wire parallel clamp smallcomplete with fasteners RI NO.1041-2 MODB)confirming to RDSO DRG.NO.ETI/OHE/P/1040-2 MOD-E or latestrevision | — | — | — | 1,50,170 | |
| — | 500.00 | — | — | ||
| Supply of Contact wire parallel clamp groove PG1030-3 with GI bolt 16x50x38mm with nutspring washer, as per RDSO drawing No.ETI/OHE/P/1030-3, Rev-A, RI No.1031-3 orlatest revision | — | — | — | 1,25,140 | |
| — | 100.00 | — | — | ||
| Supply of Feeder ending clamp (150) (1131,1102&1104) & (261, washer & pin) as per drawingno. ETI/OHE/P/1130 & RDSO specification no.TI/SPC/OHE/ Fitting/ 0130 (10/13) with A&Cslip no.1 or latest | — | — | — | 1,26,194 | |
| — | 200.00 | — | — | ||
| Supply of Contact Wire Ending clamp completeassembly, Clamp Body (Part No.1118- 3), Wedge(Part No.1119-3) and Part no.263 with fasteners (Split pin & washer) suitable for 107 sq. mmContact Wire as per latest RDSO Specification | — | — | — | 68,026 | |
| — | 200.00 | — | — | ||
| Supply of CATENARY WIRE ENDINGCLAMP [65 SQ.MM] with Complete assembly(PART NO.1121, 1094,1092 and 261) WITHFASTENERS (Pin & washers)AS PER RDSODRG NO.ETI/OHE/P/1120, MOD-B or latestrevision | — | — | — | 1,30,530 | |
| — | 100.00 | — | — | ||
| Supply of Catenary Splice (65 sq. mm)Conforming to Part RI- 1091,1092, 1093 & 1094as per RDSO Drg no: ETI/OHE/P/1090 or latest. | — | — | — | 67,832 | |
| — | 100.00 | — | — | ||
| Supply of Contact wire splice toothed typecomplete assembly with fasteners as per RDSODrg. -No ETI-OHE-P1080 -1- Mod-B and partDrg. no ETI-OHEP- 1081 - 1 mod C or latest. | — | — | — | 1,26,296 | |
| — | 10.00 | — | — | ||
| Supply of GEARLESS HAND OPERATEDPULLING AND LIFTINGMACHINE 3.2 TONNE CAPACITY (TIRFOR)as per specifications | — | — | — | 2,92,440.6 | |
| — | 10.00 | — | — | ||
| Supply of GEARLESS HAND OPERATEDPULLING AND LIFTING MACHINE 1.6TONNE CAPACITY (TIRFOR) as perspecifications | — | — | — | 1,95,997.4 | |
| — | 20.00 | — | — | ||
| Supply of RATCHET LEVER HOIST (PULLLIFT) OF 0.8 TON CAPACITY AS PER RDSOSPECIFICATION | — | — | — | 1,56,798 | |
| — | 20.00 | — | — | ||
| Supply of RATCHET LEVER HOIST (PULLLIFT) OF 1.6 TON CAPACITY AS PER RDSOSPECIFICATION | — | — | — | 1,84,175.4 | |
| — | 1.00 | — | — | ||
| Supply of 25 kVA 25kV/230V auxiliarytransformer with DO fuse assembly, jumper &fittings, LV box & anticlimbing device, 9-Tinsulator and earthing station | — | — | — | 1,55,572.79 | |
| — | 1.00 | — | — | ||
| Erection, testing and commissioning of 25 kVA25kV/230V auxiliary transformer with DO fuseassembly, jumper & fittings, LV box &anticlimbing device, 9-T insulator and earthingstation | — | — | — | 8,169.91 | |
| — | 1.00 | — | — | ||
| Dismantling of 25 kVA 25kV/230V auxiliarytransformer with DO fuse assembly, jumper &fittings, LV box & anticlimbing device, 9-Tinsulator and earthing station | — | — | — | 8,169.91 | |
| — | 500.00 | — | — | ||
| Erection of 2x150 sqmm aluminium cable as perexplanatory notes | — | — | — | 17,960 | |
| — | 2000.00 | — | — | ||
| Supply of UV Stabilized, Nylon HDPE netinside OHE structures as per latest RDSO specifications | — | — | — | 2,11,440 | |
| — | 2000.00 | — | — | ||
| Erection of UV Stabilized, Nylon HDPE netinside OHE structures as per latest RDSOspecifications | — | — | — | 1,16,620 | |
| — | 500.00 | — | — | ||
| Supply of Anti-bird Disc suitable forporcelain/composite type Bracket/stay/9- tonneinsulators as per Latest RDSO specifications | — | — | — | 3,36,535 | |
| — | 500.00 | — | — | ||
| Erection of Anti-bird Disc suitable forporcelain/composite type Bracket/stay/9- tonneinsulators as per Latest RDSO specifications | — | — | — | 41,930 | |
| — | 3500.00 | — | — | ||
| Supply of Copper feeder wire 150sqmm withrequired fittings as per technical specificationsand explanatory notes. | — | — | — | 69,32,205 | |
| — | 3500.00 | — | — | ||
| Erection of feeder wire/cross feeder wire/largespan wire as per explanatory notes. | — | — | — | 3,75,445 | |
| — | 3500.00 | — | — | ||
| Dismantling of feeder wire/cross feederwire/large span wire as per explanatory notes. | — | — | — | 1,87,705 | |
| — | 1.00 | Lumpsum | — | ||
| Power block charges for Erection of item no 4 7 9 11 13 15 17 19 21 23 26 28 29 37 38 41 42 43 44 47 64 66 68 69 (30 percent of the erection value) | — | — | — | 16,68,546.76 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022.pdf
ATTACHMENT
GCCACS1to11.pdf
ATTACHMENT
TenderDocs21.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].