| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 CrAccepted-AOC HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | ₹4.9 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹5.1 Cr+₹21.4 L (4.37%)Rejected-Finance | ₹5.1 Cr+₹21.4 L (4.37%) | L2 | Rejected-Finance Quoted rates higher than L1 |
| 3 | L3₹5.1 Cr+₹21.9 L (4.48%)Rejected-Finance | ₹5.1 Cr+₹21.9 L (4.48%) | L3 | Rejected-Finance Quoted rates higher than L1 |
| 4 | L4₹5.1 Cr+₹24.8 L (5.07%)Rejected-Finance | ₹5.1 Cr+₹24.8 L (5.07%) | L4 | Rejected-Finance Quoted rates higher than L1 |
| 5 | L5₹6.0 Cr+₹1.1 Cr (21.9%)Rejected-Finance | ₹6.0 Cr+₹1.1 Cr (21.9%) | L5 | Rejected-Finance Quoted rates higher than L1 |
Tender Value
₹4.5 Cr
EMD Value
₹5.1 L
Closing Date
25 Apr 2024, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Construction of Std Guard House and Security control rooms and ancillaries for augmentation nof security infrastructure and control devices at HQ SAC Under GE AF Trivandrum
2024_MES_645550_1
CWE(AF)TVM/82496/E8 Std Guard house TVM
Open Tender
Construction Works
Lump-sum
365 days
Trivandrum
Class A category a(i)
7 documents required · 7 mandatory
₹2,000
GE AF Trivandrum
₹5.1 L
Yes
21 May 2024
7 Mar 2024
29 Apr 2024
7 Mar 2024
25 Apr 2024
11 Apr 2024
8 Mar 2024 - 20 Mar 2024
Amount
GENERAL SUMMARY (Note : Schedule 'A' Part I to IX are prepriced by MES under Ser No. 2 to 8.Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only)
Total of Schedule ‘A’ Part I “BUILDING/STRUCTURES ”
Total of Schedule ‘A’ Part II “SITE CLEARANCE ”
Total of Schedule ‘A’ Part III “ INTERNAL ELECTRIFICATION”
Total of Schedule ‘A’ Part IV “HARD STANDING AND BOULDER PITCHING”
Total of Schedule ‘A’ Part V “ RETAINING WALL”
Total of Schedule ‘A’ Part VI “ AREA DRAINAGE AND COVERSLAB FOR EXISTING WELL”
Total of Schedule ‘A’ Part VII “ SEWAGE DISPOSAL”
Total of Schedule ‘A’ Part VIII “INTERNAL WATER SUPPLY”
Total of Schedule ‘A’ Part IX “EXTERNAL WATER SUPPLY”
Total of Schedule ‘A’ Part X “AIR CONDITIONING”
Total of Schedule ‘A’ Part XI “FIRE DETECTION AND ALARM SYSTEM”
Total of Schedule ‘A’ Part XII “EXTERNAL ELECTRIC SUPPLY”
Sch 'A' Part- XIII - Misc Items (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6)
PILE FOUNDATION Note :- 1. The depth of pile embedded in pile cap will not consider for measurement. 2. The pile has to be casted up to the ground level and have to demolish up to bottom of pile cap as shown in drawing. 3. Demolition of concrete of piles from GL to the bottom of pile cap will not be considered for measurement. 4. Contractor has to quote the rate accordingly.
Boring for Bored cast in situ piles in soil and getting out and disposal of spoil to a distance 50 metres using DMC method (Direct mud circulation) 500mm dia piles compleet all as specified and as directed.
M&L RCC M-35 design mix concrete for 500mm dia bored cast in situ pile from cut off level to any length complete all as specified and as shown on drawings.
Excavating over areas, n exc 1.5 m deep and getting out and getting out in solft/loose soil complete all as specified and as directed.
M & L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate ) as in foundation bed concrete complete all as specified and as directed.
M & L RCC M 35 design mix concrete in pile caps complete all as specified and as directed and as shown on drawings.
M & L Steel Formwork and steel props to sides of pile cap vertical or to batter in rough finished flat concrete surfaces complete all as specified and directed.
Returning and filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil etc complete all as specified and directed.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
S&F mild steel TMT bar 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm including clips, in piles and pile caps complete all as specified and as shown on drawings.
same as per item no. 23, but 5mm dia and over in stirrups, spacers & circular hoops etc for pile and pile cap complete all as specified and as shown on drawings.
Testing of piles ( initital load test in compression) all as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in situ pile.
Testing of piles (Initial Lateral load test ) all as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500, dia cast in situ pile
Testing of piles ( routine load test in compression) all as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500mm dia cast in situ pile.
Testing of piles (Routine Lateral load test ) all as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500, dia cast in situ pile.
Testing of piles (Pile integrity test ) all as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500, dia cast in situ pile.
SEWAGE DISPOSAL
Supply and installation of 30 users Hume type septic tank complete all as specified and as directed.
RETAINING WALL
M &L for filling micro pile with cement and M sand grout in the ratio 1:1 to be placed under gravity head complete all as specified and as directed.
Steel Formwork and steel props to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished complete all as specified and directed.
Steel Formwork and steel props to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter in rough finished complete all as specified and directed.
Supply & filling with granular soil, inlcuding spreading, levelling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
AIR CONDITIONING
Supply and install testing commissioning of Split Acs with inverter type comprising of indoor / outdoor with copper coil single phase 230 V, 50 Hz complete with cordlesss remote control unit with BLDC compressor, including necessary fixing arrangement complete unit shall be placed suitable position and height inside the room and outdoor unit at suitable place outside the room on plinth height/on wall or roof as suitable and including metallic bracket with fixing bolts for outdoor unit, insulated copper piping at required length at site, Refrigerant R 32 of capacity 1.5 TR (Copper type )5 star rated complete all as specified and directed.
Supply and install testing commissioning of Split Acs with inverter type comprising of indoor / outdoor with copper coil single phase 230 V, 50 Hz complete with cordlesss remote control unit with BLDC compressor, including necessary fixing arrangement complete unit shall be placed suitable position and height inside the room and outdoor unit at suitable place outside the room on plinth height/on wall or roof as suitable and including metallic bracket with fixing bolts for outdoor unit, insulated copper piping at required length at site, Refrigerant R 32 of capacity 1 TR (Copper type )5 star rated complete all as specified and directed.
Supply and fix voltage stabliizer for automatic operation single phase naturally air cooled indoor type & designed for input variation vetween 170 V to 250 V with output voltage stablized at 230 V with accuracy of +- 205% and of capacity 4 KVA complete all as specified and directed.
FIRE DETECTION
Supply and fix Rosette plate (for detector above false ceiling only) complete all as specified and directed.
Supply and lay 2 core 1.5 sq mm copper conductor PVC insulated / FRLS armoured cable complete all as specified and directed.
Supply and fix 25 mm dia PVC conduit / 25 mm PVC casing complete all as specified and directed.
DG SET
Supply install testing and commissioning Auto Mains Failure silent type Diesel Engine Generating sest 415 Volts 58.50 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self exicited self regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Trivandrum and confirming to condition uner IS 10002, 13364 Part I 1992, BS 5514/5000 with following:- (i) The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS Standards design. Note : (i) The quoted rate shall be deemed to be inclusive of first fill of oil and final sucessful acceptance test. (ii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS in presence E/M Offr detaled by Accepting Officer, all testing arrangements/equipments shall be made available by the contractor for tests. (A). Alternator:- Standard desisgn alternator rated at 50 KVA/nearest higher available capacity at 0.8 (lag) power factor AC, 3 phase 4 - wire 415 volts 50 Hz, 1500 RPM, self regulated screen protected drip proof brushless design with winding in pole faces insulating class 'H' and voltage regulation of ± 1% at rated voltage from no load to full load.The alternator shall be confirming to BS 5000, IS : 13364 Part I (1992) and shall be in position to generate supply with frequency regulation with in ± 1% tolerace.
The alternator will be suitable for tropical climate and shall generally confirm to BS-2613/5000/IS-4722. (i) Insulation class - 'H' (ii) Temparature rise Class-'H' (iii) Excitation : Self Excited (iv) Regulation performance. The voltage is kept constant with +1% manual voltage adjustment within + 5%. (v) Frequency regulation +1%. (B) Diesel Engine:- Adequate capacity of Diesel engine as accepted by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation sailent featurers of accessories shall be as under:- (i) Fly wheel with housing (ii) Cooling sytem:- Moulded radiator with fan and belts (iii) Cooling water pump:- Centrifugal type belt driven. (iv) Exhaust System:- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade upto and outside the building covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall/enclosure. Turbo charger type, Exhaust manifold, Silencer : Residential type.
(iv) Fuel System:- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated for 1% speed/frequency regulation. Fuel hoses. (v) Lub Oil System:- Lubricating oil filter, Lubricating oil pump (vi) Air Intake System:- Air intake Manifold, Air cleaner dry type (vii) Governer electronic (viii) Starting system:- Electric Self starter with and including battery charging alternator (ix) Batteries of maintenance free of capacity 12V, 150AH-02 Nos complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and : Starter gear ring, Start and stop push button, lgniition key/switch.Handing and Operation. Sailent features of accessories shall be as under : Radiator with blower fan, Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass. (C) AMF Panel:- Factory made indoor type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 415 volts 3 - phase 4 - wire AC 50 Hz, including suitable powder coated, copper bus bar TPN for 160 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multistranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisiting of 4 pole MCCBs 250 Amps, 25 KA adjustable type - 02 Nos and Contractors of capacity 250 Amps AC 3, 415 Volts heavy duty TPN, Air break type. Detachable cable gland plates all controls, indicators and standard fitting shall be as follows:-
Multifunction meter for voltage current kWh, kWA power factor measurement. Annuciation with indication lamps for : (i) Low lub oil pressure, (ii) High Water Temparatre (iii) Engine over speed (iv) Battery low voltage (v) Over voltage, under voltage and over current vi) Multifunction meter Controls: (a) Load on indication (b) Load off indication (c) Engine start push button (d) Engine stop push button (e) Fault accept/reset push button (f) Battery charger shall be provided as per manufacturer guidelines. (i) NAL approved as per CPCB - IV norms. (ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board (iii) The generating set batteries and control panel should be inside the enclosure (iv) Fuel tank should be in side the enclosure (v) Construction Details/specification are as follows:- (a) Outer body:- CRCA sheet of 1.6mm thick (b) Doors:- CRCA sheet of 1.6mm thick (c) Sound Insulation:- 100mm thick rock wool/fire resistance foam (minimum density 64 kg/Cum) as per standard manufacturing
(vi) The accoustic should be composite in construction and fully assembled integral unit (vii) The batteries should be placed inside the enclosure beside the DG set on a suitable insulated plat form. (viii) The DG set should be provided with external Emergency stop push button (ix) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings. (x) The noises level should be 75 dB at 1m under free field condiitons (xi) The accoustic enclosure parts shall be of power coated after pre treatment process. The base frame should be painted with epoxy based black shade, Make of Engine:- Kirloskar Oil/Cummins/Greaves Make of Alternator:- Kirloskar Green/Jyoti/Stamford. Note :- (i) The complete DG set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE. (ii) Anything missed out above but technically required for efficient working of DG set is deemed to be included in quoted rates.
M&L for earthing complete with galvanised steel earth plate electode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, conected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR connected to earthing test point all as specified or indiesled complete with excavation and earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe wiht GI funned with wire mesh 40mm bore GI pipe (light grade) for protection of earth lead conductor all as directed and testing on completion.
EXTERNAL WATER SUPPLY
M&L for construction of brick masonry valve chamber of size 600mm X 600mm X 750mm with foundation in PCC 1:4:8 type D2, brick work built in CM 1:4, plastering internal surfaces completely and external surfaces upto 150mm below ground level, 15 mm thick in CM (1:4) 100mm thick (1:3:6) Type C1 coping 40 x 40 x 6mm angle iron with 3mm thick MS sheet cover complete with handle locking arrangement including painting steel and iron surfaces with two coats of synthetic enamel paint over a coat of zinc primer complete as directed by Engineer-in-Charge.
M&L for cutting the existing pipe line in position and inserting medium grade ISI marked GI Tee and one number union of 25mm dia medium grade 40x40x25 mm for making branch connection all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 1/2 /4 core XLPE, armoured, AI conductor cable of size 25 to 50 Sqmm, Indoor/Outdoor type, complete all as specified and directed.
All as per description of ser item No-52 above but cable of size 70 to 95 spmm, Indoor / Outdoor type, complet all as specified and directed.
M&L for Fabrication and fixing of street light bracket made of 40 mm dia GI tubing light grade, 1.5 metres long, bent to shape fixed to pole with 50 mm x 6 mm GI clamps incl two run of 2.5 Sqmm PVC insulated sheathed copper conductor cable from triominal box to street light fitting steel tubular pole.
Supply and fix high power LED 60 W die-cast aluminum IP66 PDC street light luminiare Make-Crompton Cat Pt-LSTP-60CDL or equivalent of Philips /Wipro /Bajaj.
S & F hot press moulded SMC junction / terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 4 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable conbnections, connecting incoming and or out going cables by providing suitabler of size of cable lugs/glands, fixied on pole by means of clamps.
Supply, install, test and commissioning of Transformer 100 KVA, step down, outdoor type11/0.433 KV, 50Hz, AC double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connection on LV side in accordance with vector symbol DyN-11 (vector group 4) and having tapping of + 7.5% in equal step of 2.5 % changed by means of off load tap changing arrangement. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings /accessories as specified in SSR Part -I and IS -2026. The transformer should have cable box on LT side and HT side. The limit of temp rise after continuous full load run as specified in SSR part-I and IS - 1180 Part I : 2014 and BEE certified shall be suitably adjusted to suit the maximum ambient temp prevailing at site all as specified comprising with and including the following specifications:- (i) 01 No Cable box on LT side consisting of 04 Nos porcelain bushing with bushing brass rods and nuts washers and cable glands of suitable for reception of cable LT 1100 Volt grade XLPE insulated heavy duty 'E' grade including gland joint complete. (ii) -do- for HT side - 03 Nos.
Item No. 57 Contd/.. (iii) Oil Conservator with filter type drain valve and oil level guage. (iv) Dehydrating Breather with first filling of Dehydrating Agent. (v) Explosion Vent. (vi) Thermometer Pocket (vii) Two Earthing Terminal on tank body to facilitate fixing of 32x6mm GI strips. (viii) Rating plate with terminal marking plate. (ix) Oil level guage. (x) Oil drain filter valve. (xi) Oil filling port on top cover with plug. (xix) Oil temp indicator of approved range ,including shut of valve between conservator and main tank. (xx) Drain valve with threaded adaptor. (xxi) Filter valve with threaded adaptor. (xxii) Sample valve. (xxiii) Extra bushing for neutral out side the LV side.
Supply, install, testing and commissioning of ABB Make 11 kV load break switch , 630A, 20kA, Motor operated, Compact, Outdoor type, both side Extensible, Non drawout type, +CCC+ (1 No. Fixed type motor operated LBS as incomer and 2 Nos. Load Breaker Switch outgoing) SAFEPLUS compact gas insulated, All live parts enclosed in a robotically welded stainless steel tank of IP 67 class of protection. With Battery and Battery Charger.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination / joint kit complete with Jointing material heat Shrink type and accessories suitable of 3 core XLPE, armoured, AI conductor cable of size 120 spmm, Indoor / Outdoor type, complet all as specified and directed.
Supply, install, connect, test and commissioning of 3 phase 4 wire 50 Hz 433 volts outdoor Lt distribution panel board, compartmentalised cubical type, dust and vermin proof, free standing floor mounting type mounted on and incl 1:3:6 PCC plat from with required mounting channel, panel board fabricated out of 3.15 mm thick CRCA steel sheet duly pre treated and powder coated factory made with alley, gland plates incl cable glands of suitable sizes and consiting the following (for CCTV Cameras):- (a) MCCB 4 pole 200 Amps 25 KA - 01 Nos incoming (b) MCB TPN 32 Amps - 06 Nos outgoing (02 Nos - spare)
Supply, install, connect, test and commissioning of 3 phase 4 wire 50 Hz 433 volts outdoor Lt distribution panel board, compartmentalised cubical type, dust and vermin proof, free standing floor mounting type mounted on and incl 1:3:6 PCC plat from with required mounting channel, panel board fabricated out of 3.15 mm thick CRCA steel sheet duly pre treated and powder coated factory made with alley, glands sutiable sizes and consisting the following:- (a) MCCB 4 pole 200 Amps 25 KA - 01 Nos incoming (b) MCB TPN 32 Amps - 08 Nos outgoing (06Nos for pillar boxes & 02 Nos for Guard rooms (c) Electronic timer switch with triple pole power contractor 20 Amps for control of street lights - 1 Set (d) Change over switch 415 V in pole of capacity 200 Amps - 01 Nos
M&L for road cutting 45 cm wide and 75 cm deep and making good to match with existing surface complete all as specified and directed by Engineer-in-Charge.
S&F all in one integrated Solar LED Street Light fitting 20 W 2500 Lumens complete with octagonal ple and mounting backets all as specified and directed. Make : Havells cat pt No LHSTARU7AAN1020
Archana Transport
G ANILKUMAR
B5BUILDING SOLUTIONS
Modern Engineering Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .