Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹6.6 L+₹47,050 (7.71%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹6.6 L+₹53,990 (8.85%)Rejected-Finance 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹7.6 L+₹1.5 L (23.9%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹8.4 L+₹2.3 L (38.3%)Rejected-AOC PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹5.8 L
EMD Value
₹11,600
Closing Date
18 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
PROVISION OF CERTAIN E/M MINOR WORKS AT AF STATION BARODA
2021_MES_411569_2
8610/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹11,600
Yes
2 Mar 2021
3 Feb 2021
20 Feb 2021
3 Feb 2021
18 Feb 2021
4 Feb 2021
60 days
Amount
M & L for point wiring with 1.5sqmm FRLS single core sheathed multistrand copper conductor cable drawn through and including ERW pipe of 16 SWG with accessories, joint boxes/ terminal boxes 60mm deep with 3 mm thick plastic laminated sheetcover for mounting or housing switches and continuous earthing and earthing connections including FRLS single core sheathed multistrand copper cables 1.5 sq.mm size as in earth wire for one light point controlled by one one way switch complete all as specified and directed.
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F flameproof type FLP-WP made ceiling fan 1200mm sweep complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable heavy duty fastener for hanging the fan complete all as specified and directed.
Material and labour for point wiring for one light point or one fan point controlled by one one way switch using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade in and incl concealed PVC conduit (medium grade) of suitable size all as specified and directed with using new sunken type pressed steel box/terminal boxes for mounting fittings/junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
S&F switch piano flush type 5 Amps single pole, one way, 230 volts AC circuit complete all as specified & directed.
S&F ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed.
S&F Exhaust fan 300mm sweep single phase 230 volts ISI marked complete all as specified and directed. Note :- The rate quoted is deemed to include for all necessary arrangments such as wooden frame/cut in existing frame/or making hole in wall, making good the disturbed surface of wall.
Supply and instalation & testing of fast earth electrode maintenance free chemical earthing, dual electrode technology of 3 mtr long copper pipe of diameter 76 mm(OD). There should be terminal for connection of 20x3 mm of copper strip with two holes of 14 mm diameter. FAST ELECTRODE is duly filled with the highly conductive material with sealing at both ends with lead terminals of 20x3 mm copper strip at top, alongwith 2 bags of 25 Kgs each of premium grade ground improving SRIP (BFC) earth enhancing compound and HDPE heavy duty earthing chamber cover size 260x300x300 mm with FRP based earthing display board with support stand size 254x380x610 mm. The chemical should be tested and certified by any international accredited laboratory. The earthenhancing compound should be tested referring to protocol IS 1350/&/EC62321/111/54/CDV. The PH value of compound should be between 7 to 8. The content of mercury (Hg) & Hexacromium should be below detection level. The electrode should be tested for salt spray test as per BIS117-09 for corrosion for minimum 500Hrs. The FAST ELECTRODE shall be dully tested & Certified by CPRI (Central Power Reserch Institution), Govt of India for a suitable minimum short circuit current for 1 second with initial pick of suitable KA. The Fast ELECTRODE shall be approved by CPRI, ERDA/NABL Lab complete all as specified and directed.
Supply and fix copper strip 20 mm x 3.15 mm complete with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
S&F insulating clamp on the wall/ roof for fixing of copper strip complete all as specified and directed.
Supply and fix test point terminal block made of GI Sheet box of size 90x90x90mm made of 1.6mm thick plain sheet and screwed to wall for protection of test point complete all as specified and directed.
M&L Galvanised tubing light grade 20 mm dia with all fittings buried under floor or fixed on wall for earth lead protection complete all as specified and directed.
Supply, installation, testing & commissioning of hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality of capacity 2.0 TR 230 volt AC 50 c/s of minimum 5 star rating WITH YEAR OF MANUFACTURING 2020 and EER 3.2 and comrising of the following:- (a) 2.0 Ton capacity using Eco friendly refrigernt cooling unit wall mounting type complete with remote control, draining out arrangement, manually adjustable cover for cool air from front with and inter connection with the condensing unit etc all as specified and directed by Engr-in-charge. (b) One number condensing unit of 2.0 ton capacity comprising of all fitting such as single phase electric driven compressor, condensing fan motor, condensor with fixing of stand on wall and all necessary controls and accessories all as specified and directed by Engr-in-charge. Note :- Aditional lenth for copper tubing if required at site shall be supplied and fixed by the contractor without any extra cost.
Supply and fix MCB, single pole 240 volts 40 to 63 Amps capacity B series fixed in DB's complete all as specified and directed.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SP 20 Amps complete all as specified and directed.
M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, FR PVC insulated & unsheathed complete all as directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm earth cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
Supply anf fix Voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with accuracy of + 2.5 % and of capacity 5KVA complete all as specified and directed.
Supply and fix MCB DB 4 way vertical load line sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incomer complete all as specified and directed. Make:- Schneider as per cat No :A9HVD04L or equivalent make of Seimens /Legrand . Note : (i) MCB shall be measured and paid seperately under appropriate item of this schedule . (ii) Copper thimble shall be used for connection of cable .
Supply and fix MCB DB 4 way sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incomer complete all as specified and directed. Make : Schneider as per cat No :A9HTND04E or equivalent make of Seimens /Legrand . Note : (i) MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule. (ii) Copper thimble shall be used for connection of cable .
Supply and fix MCCB four pole 160 amps FP 415 Volts breaking capacity 36 KA as per IEC 60947-2 complete all as specified and directed.
Supply and fix MCCB three pole 100 amps 415 Volts breaking capacity 25 KA as per IEC 60947-2 complete all as specified and directed.
Supply and fix MCB, single pole 240 volts 6 to 32 Amps capacity B series fixed in DB's complete all as specified and directed.
M & L for sub main wiring using four single core 10 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, FR PVC insulated & unsheathed complete all as directed. Note: (i) Four runs of 10 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling and connecting to earth dolly and including 2.5 Sqmm earth wire, FR PVC insulated & unsheathed complete all as directed. Note: (i) Two runs of 4 sqmm and one run of 2.5 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
Earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 3 of SSR Part-I and connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber, 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement at 10 cm c/c spacing both ways, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia upto 7.5 mtrs from the earth plate electrode & refillling of soil etc including necessary excavation & earth work in any strata complete all as specified and directed by Engr-in-Charge.
Testing existing units of 2 Ton/1.5 Ton split type/window type AC, Indoor/outdoor components complete with copper condenser, non CFC refrigerent type, cordless remote control system unit by taking down and reinstallation after testing complete all as specifeied and directed by Engineer in charge.
S & F Copper Tubing suitable for Split AC as in connection between inner unit and outer unit complete all as specified and directed.
M&L for Point wiring for one power socket 15 Amps oulet controlled by one one/way switch complete with 2.5 sqmm single core PVC insulated and PVC unsheathed (FR) multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves Dash fastners and cadmium plated screws all as per ISI including sunk type boxes with 3 mm thick phenolic Laminated sheet top covers for mounting fitting like switches, socketes fan regulators etc including 1.5 Sqmm single core multi stranded copper conductor FR PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly complete all as specified and directed.
M&L for GI pipe 15 mm dia medium grade for water connection including all fitiing like Tee, elbows , union, socket and nipples etc required for connections complete all as specified and directed.
S&F pillar tap fancy type, chromium plated with long shank and cup (concealed type) 15mm bore screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F stop valves/angle valve fancy type, chromium plated with long shank and cup (concealed type) 15mm bore screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F earth industrial plug in socket metal clad suitable for 20 Amps 240 volts metal clad MCB DB complete all as specified and directed.
S&F of steel connection with nuts, connector duly threaded internally on both ends of size 18” (45Cm) long complete all as specified and as directed.
Supply and installtion of electric geyser of capacity 50 lts, 3 star rated including grouting of nuts and bolts for fixing arrangement and making good disturb surface complete all as specified and directed. Note : All necessary arrangemnt for fixing of geyser such as drilling/fixing anchor hold fastener deemed to be included in quoted rate.
S&F Timer switch DAT (Dual AC Timer) suitable for 1 incoming and 2 outgoing 230 volts ISI marked complete all as specified and directed. Make: skylet/Havells,CG,Bajaj or equivalent
S&F Timer switch DTS 120/4 suitable for 1 incoming and 1 outgoing 230 volts ISI marked complete all as specified and directed. Make: skylete/Havells,CG,Bajaj or equivalent
M&L for Point wiring with 1.5 sqmm single core PVC insulated and PVC unsheathed (FR) multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves Dash fastners and cadmium plated screws all as per ISI including sunk type boxes with 3 mm thick phenolic Laminated sheet top covers for mounting fitting like switches, socketes fan regulators etc including 1.5 Sqmm single core multi stranded copper conductor FR PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly complete all as specified and directed for the following:-
One light/Fan point controlled by one one/way switch
One 5 pin 5 Amps socket outlet on independent board.
One 5 pin 5 Amps socket outlet on same board with other switch.
Supply and fix LED flood light fitting 90 watt innovative fixture with IP66 pressure die cast alluminium housing and toughened glass in the front with uniqe flood optics to ensure uniform distribution of the light and saving of 50% as compared to conventional system lumen all as specified and directed by Engr in charge Make: cat part no FLOOD 90WAT of Syska, cat part no RE260318047 of Crompton Greaves or equivelant make.
S&F switch socket combination 5 pin 5 Amp flush type complete all as specified and directed.
S&F switch socket combination 5 pin 5 and 15 Amp 2 in one flush type complete all as specified and directed.
Sukhi Electricals
Chanda Construction Co.
Shiv Kripa Tradimg
K A ELECTRIC CO
SLB Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .