| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAdmitted-Finance DEHRADUN | ₹8.4 L | L1 | Admitted-Finance |
| 2 | L2₹8.6 LAdmitted-Finance 3491 14 HARIPURA DHAPAI ROAD AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹8.6 L | L2 | Admitted-Finance |
| 3 | L3₹9.1 LAdmitted-Finance DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹9.1 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TARUN ENGINEERING WORKS L3 | Malik Associates L1 | AMARJEET SINGH AND CO. L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor) including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any othet loose material and removing the demolished material outside the MOD land.Complete all as specified and directed | 21.04 | cum | 300 ₹6,312 | 200 ₹4,208 | 410 ₹8,626.40 |
| 2.00 | Providing and application two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge .
Note : Ponding test after water proofing coating willl be done for ponding for 48 Hrs . | 88 | sqm | 150 ₹13,200 | 80 ₹7,040 | 750 ₹66,000 |
| 3.00 | M/L for 15 mm thick protection plaster CM 1:4 floor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction ).Complete all as specified and directed
Note :- The rates of SBR quoted shall not be deemed to be included for these items and same will be seperately under respective item. | 88 | sqm | 230 ₹20,240 | 200 ₹17,600 | 450 ₹39,600 |
| 4.00 | M/L for providing 40 mm dia GI pipe (medium grade) spout projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge | 5.4 | Rm | 350 ₹1,890 | 210 ₹1,134 | 410 ₹2,214 |
| 5.00 | M&L for cement concrete 1:5:10 type E2(using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and directed.Complete all as specified and directed | 21.04 | Cum | 2,500 ₹52,600 | 3,000 ₹63,120 | 2,500 ₹52,600 |
| 6.00 | M&L for 30 mm thick PCC Type B-0, 1:2:4, (using 12.5 mm graded stone aggregate) as in floor mixed with Liquied water proffing compound.
Note :- WPC will be measured and paid seperately | 48 | sqm | 400 ₹19,200 | 250 ₹12,000 | 250 ₹12,000 |
| 7.00 | Supply only SBR Latex liquid polymer of approved make. | 3 | Ltr | 200 ₹600 | 200 ₹600 | 250 ₹750 |
| 8.00 | Dismantling of cast iron or reinforced concrete drain pipes up to 110mm dia , jointed in cement mortar and taking out of trenches if required . | 130 | R M | 50 ₹6,500 | 11 ₹1,430 | 25 ₹3,250 |
| 9.00 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors. | 20 | R M | 120 ₹2,400 | 150 ₹3,000 | 150 ₹3,000 |
| 10.00 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors. | 50 | R M | 160 ₹8,000 | 180 ₹9,000 | 210 ₹10,500 |
Updated dates
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
11 May 2026, 6:00 pmClosed
AGE (i) RAIWALA
AGE (i) RAIWALA
REPAIR/REPLACEMENT OF FLOORING INCL TILLING WORKS IN HALL KITCHENS TOILETS BATHROOMS AND SUNKEN PORTION INCL NECESSARY WATER LEAKAGE TREATMENT AND OTHER CONNECTE BR WORK AT ZONE C AT MIL STN RAIWALA UNDER AGE (I) RAIWALA
2026_MES_760530_1
8129/E8
Open Tender
Civil Works
120 days
AGE (I) RAIWALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) RAIWALA
₹18,000
Yes
16 May 2026
16 Apr 2026
13 May 2026
16 Apr 2026
11 May 2026
28 Apr 2026
16 Apr 2026 - 27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor) including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any othet loose material and removing the demolished material outside the MOD land.Complete all as specified and directed | - | cum | - | - | |
Providing and application two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge .
Note : Ponding test after water proofing coating willl be done for ponding for 48 Hrs . | - | sqm | - | - | |
M/L for 15 mm thick protection plaster CM 1:4 floor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction ).Complete all as specified and directed
Note :- The rates of SBR quoted shall not be deemed to be included for these items and same will be seperately under respective item. | - | sqm | - | - | |
M/L for providing 40 mm dia GI pipe (medium grade) spout projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge | - | Rm | - | - | |
M&L for cement concrete 1:5:10 type E2(using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and directed.Complete all as specified and directed | - | Cum | - | - | |
M&L for 30 mm thick PCC Type B-0, 1:2:4, (using 12.5 mm graded stone aggregate) as in floor mixed with Liquied water proffing compound.
Note :- WPC will be measured and paid seperately | - | sqm | - | - | |
Supply only SBR Latex liquid polymer of approved make. | - | Ltr | - | - | |
Dismantling of cast iron or reinforced concrete drain pipes up to 110mm dia , jointed in cement mortar and taking out of trenches if required . | - | R M | - | - | |
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors. | - | R M | - | - | |
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors. | - | R M | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
TD8129.pdf
Tender Documents • 1.83 MB
MAKEAPPROVAL.pdf
Additional Documents • 15.01 MB
BOQ_851873.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid