| 1 | L1₹14.4 LAccepted-Finance | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹14.6 L+₹20,195 (1.41%)Accepted-Finance | L2 | Accepted-Finance SECOND LOWEST |
Tender Value
₹12.5 L
EMD Value
₹25,071
Closing Date
23 Jun 2023, 11:30 amClosed
Executive Engineer (Civil)
Executive Engineer (Civil), BSNL Civil Division,Trichy
Erection of 40M (Flood light type) Narrow base tower including Foundation, Engine bed,Earthing , Gantry and Erection of BTS Shelter at VADASERI, Thanjavur BA.
2023_BSNL_157494_1
002/EE/BSNL/CD/TRY/2023-24
Open Tender
Civil Works
Item Rate
90 days
Trichy
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Yes
AO(Cash), BSNL, Trichy
₹25,071
Yes
23 Jun 2023
15 Jun 2023
23 Jun 2023
15 Jun 2023
23 Jun 2023
15 Jun 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed :
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming watering, lead up to 50m and lift up to 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in :
All kinds of soil.
Providing and laying in position cement concrete of specified grade, excluding the cost of centering and shuttering : All work upto plinth level :
1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
1 : 4 : 8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement : All work upto plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Lintels, beams, plinth beams, girders bressumers and cantilevers.
Columns, pillars, piers, abutments, posts and struts.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Thermo-Mechanically Treated bars.
Smooth finishing of the exposed surfaces of reinforced cement concrete work with 6mm thick cement mortar 1:3 (1 cement : 3 fine sand).
Structural steel work riveted, bolted or welded in built up sections, trusses and framed ork, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (item will be operated for Horizontal Gantry etc).
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Labour charges for fixing anchor bolts using templates during laying stem concrete including levelling and fixing properly as directed by the Engineer-in- charge. (Rate excluding the cost of anchor bolts) using proper templates.
Supplying high tensile strength fasteners consisting of galvanised iron nuts, washers and spring washers of varying sizes at appropriate locations as directed by the Engineer in charge. (Item is meant for suppplying missing bolts & nuts in the tower material supplied by the Department).
Providing & placing in position prefabricated structure made up of 4 nos of GI plates of size 600mm x 600mm x 6mm interconnected by GI flat of size 50mm x 3mm with and with lead sheath between GI plates and flats andnuts and joints being made moisture proof necessary GI bolts providing and placing in position watering pipe of 20mm dia GI pipe of length 3.0 m with funnel at top including filling finely sieved good soil for earth pit size of 2.0m x 2.0m upto a height of 1.5m from the bottom as per specification for earthing, brick masonry chamber of size 300x300x300mm with CI cover and as directed by the Engineer-in-charge. (The galvanising shall be as per IS 4759 with average mass of zinc coating of 610gm/sqm, i.e. approximately 85 micron. The GI flat to be paid for separately)
Providing and laying ring earth by excavating trenches a trench of 300 mm width and 1500 mm deep and at bottom of the then laying GI strip of 50x3 mm at the bottom of the trench and connecting it to all the tower legs withGI strip of 50 mx3 mm with GI bolt and nuts and also making provision for connecting ring earth to lightning spike by providing 50x3 mm GI strip one end of which is connected to the ring earth by means of GI bolts and nuts and other end left free above by Engineer-in-charge.(Earthwork and refilling paid separately under relevant items)
Providing and fixing GI strip of size 50 x 3 mm with necessary GI clamps at every 1.50m, interval with Porcelain insulator, bolts, nuts, screws, etc.along with vertical runway including connecting with lightning spike at top of tower and earth at ground without overlap joint etc., complete as directed by the Engineer-in-charge. The rate includes all required materials, labours
Providing and fixing testing joint, made of 50 x 6 mm GI strip, 250mm long with 6 Nos of GI bolts, nuts, check nuts and washers etc., complete as directed by Engineer-in-charge.
Providing and fixing spike type lightening arrester made of 25mm dia hollow copper pipe of wall thickness 1.60mm and required length with necessary fixtures at top of the tower. The spike shall be insulated by Teflon material and connected to GI plate earthing by GI flat 50 x 3mm with proper lugging arrangement as directed by the Engineer-in-charge. (Cost of G.I. Flat of 50 x 3 mm shall be paid separately).
Transportation of tower materials, anchor bolts etc weighing approximately 9.00MT from Telecom store godown at Trichy to the worksite at Vadaseri, Thanjavur District including loading & unloading and lifting of tower materials as directed by the Engineer-in-charge.
Erection of four legged ground based angular light weight communication tower of 40 m height ( Approximate weight of 8500.00 Kgs ) using available M.S hot dipped galvanised sections , including sorting, lifting, assembling, fitting and fixing up all tower members in position true to alignment , including hoisting and bolting with necessary bolts, nuts and washers , fixing of ladder, working platform, cable guide rack, pipes and for lightning arrestor at required level all complete as per the directions of the Engineer in charge , including providiing necessary safety precautions to protect human lives and structures nearby during the course of erection , insurance coverage to labourers and including all tools, plants , equipments , machinery required for works as per relevant I.S codes and specification, including offering A/T all charges as directed by Engineer-in-charge
Painting of 40M Tower ( Approximate weight of Tower is 8500.00 Kgs ) with LUXOL High gloss synthetic enamel paint or equivalent in two or more coats over and including a base coats of etching primer (BISON wash primer or equivalent) and BISON HB Zinc Phosphate primer or equivalent to required shade with the colours of White and International Orange bands alternatively as directed by the Engineer-in-charge. (The Rate is inclusive of cleaning the surface of the structural members free of all rust, scales, grease and dirt, safety arrangements, lifting of painting materials to the required height upto 40 m from the base of the tower and Insurance coverage to labour and Materials )
Dismantling the existing BTS Shelter of size 3.13m x 2.14m and up to a height of 3.00 metre in the reusable manner (consisting of side panels, floor panels, roof panels/sheets, door, ASPVC flooring sheet, RSJ girders, bolts, nuts, fabricated Mild Steel steps and other fixtures) including stacking the materials at site as directed by the Engineer-in-Charge.
Transportation of BTS shelter materials as dismantled vide Item No.(21) from the NBSNL site Kolakudi to Vadaseri including loading and unloading charges as directed by the Engineer-in-Charge.
Erection of BTS shelter of size (3.13 m X 2.14 m X 3.00 m ) over steel structural members/girders and BTS plinth RCC pillars including prior segregation/ sorting of the shelter with all its accessories complete and fixing floor panels, walls panels,roofing panel and sheeting, maintaining cut out for gantry and cable entry, fixing of available door shutter and sealing of all joints with fasteners and for using joint sealant compound through out the joints for damp proof, fixing of MS steps, gantry etc. all as per the direction of the Engineer-in charge. (Shelter materials available from dismantlement have to be reused and transportation will be paid for separately)
D.MURUGAN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .