The Gujarat Cancer and Research Institute
Proposed New Construction of Cyclotron and Nuclear Medicine Building for GCRI at Asrawa, Ahmedabad
286407
2025-26
Open
Civil Works
Works
Ahmedabad
7 documents required · 6 mandatory · 1 optional
₹30,000
THE GUJARAT CANCER AND RESEARCH INSTITUTE
₹88.9 L
14 Mar 2026
14 Mar 2026
14 Mar 2026
7 Apr 2026
14 Mar 2026
DESCRIPTION TOTAL AMOUNT (In Rs.)
DESCRIPTION TOTAL AMOUNT (In Rs.)
(1) CIVIL WORK Rs.
(2) PLUMBING, WATERSUPPLY & DRAINAGE WORK Rs.
(3) FIRE FIGHTING WORK Rs.
(4) ELV WORK Rs.
(5) ELECTRICAL WORK Rs.
(5) LIFT WORK Rs.
(7) MEDICALGAS PIPELINE Rs.
B ADD GST 18% Rs.
C GRAND TOTAL Rs.
C GRAND TOTAL Rs.
D Add 3 % Contingency Charges Rs.
E Add 2 % W/C Establishment Charges Rs.
F Add 1 % Quality Control Charges Rs.
PROPOSED NEW COMSTRUCTION OF CYCLOTRON AND NUCLEAR MEDICINE BUILDING FOR GCRI AT ASRAWA, AHMEDABAD
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Chapter 026 Clearing and grubbing road land includding uprooting rank vegetation, grass, bushes, shrubs, saplings and trees
1 26117C 2719.00 girth upto 300mm removal of stumps of tress cut earlier and disposal of unserviceable materials. Sqm 2.82 0.03 2.85
Page - 213 A) By Mechanical means in area of light jungle.
Excavation for foundation including shoring & shruting upto 1.5 mt.depth All kind of Soil. including sorting out and
stacking of unuseful materials and disposing off the excavated stuff upto all lead and lift.(Excavated earth / Stuff to
be stacked and surplus earth disposed at non objectinable place to be found by the Contractor and necessary
permision to be obtained by contractor from local authority/ Government with royalty certification if applicable )
Excavation for foundation including shoring & shruting for 1.5 mt. to 3.0 mt. All kind of Soil. including sorting out
and stacking of useful materials and disposing off the excavated stuff upto all lead and lift (Excavated earth / Stuff to
be stacked and surplus earth disposed at non objectinable place to be found by the Contractor and necessary
permision to be obtained by contractor from local authority/ Government with royalty certification if applicable )
Excavation for foundation including shoring & shruting for 3.0 mt. to 5.0 mt. All kind of Soil. including sorting out
and stacking of useful materials and disposing off the excavated stuff upto all lead and lift.(Excavated earth / Stuff to
be stacked and surplus earth disposed at non objectinable place to be found by the Contractor and necessary
permision to be obtained by contractor from local authority/ Government with royalty certification if applicable )
Filling available selected / approved stacked excavated earth (excluding rock) (Earth which is stacked at any location
outside the campus non- objectionable place shall be found by the contractor) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20 cm. in depth consolidating each deposited layer by ramming and
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing etc. complete.
(Royalty shall be paid by contractor and supporting document submitted to client for verification.)
Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming
and consolidating etc. complete.
Providing and laying rubble soling, 23 cm thick, in a compact manner, foudation, road, footpath etc. using 200 to
mm. cut size stones, covering and levelling the surface with a layer of murrum after filling the voids with smaller sized
stones or stone chips, including watering, ramming well and consolidating each layer, As per drawings and design
supplied by architect and instruction given by authority and E.I.C.
Providing and filling with styrofoam/cinder (good quality) in sunks in layers of 15 cm thk including watering placing
ramming well etc. As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and laying cement concrete 1:2:4 (1Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal
10 RA - 3 1,064.00 size) and curing complete including cost of formwork in Cum 4,044.00 40.44 4,084.44
(A) Foundation and Plinth
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(B) Plinth Beam
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
13 RA - 6 219.00 all levels , heights as upto 4.50 m , excluding reinforcement . Cum 6,728.57 67.29 6,795.86
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in
(i) Up to Plinth
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights as upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) Column up to Ground Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights as upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) Column up to First Floor Slab lvl.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) Column up to Second Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) Column up to Third Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) Column up to Fourth Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) Column up to Fifth Floor Slab lvl.
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50 m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) Column up to Sixth Floor Slab lvl. (Terrace Floor Slab lvl.)
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
21 RA - 8 78.00 all levels , heights as upto 4.50 m, excluding reinforcement . Cum 6,765.92 67.66 6,833.58
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(D) RCC Wall up to Ground Floor Slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 to accelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(D) RCC Wall up to First Floor Slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 to accelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(D) RCC Wall up to Second Floor slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(D) RCC Wall up to Third Floor Slab lvl .
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(D) RCC Wall up to Fourth Floor Slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(D) RCC Wall up to Fifth Floor Slab lvl .
Providing and laying in position control cement concrete mix M-35 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(D) RCC Wall up to Sixth Floor Slab lvl .
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
29 RA - 10 408.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,580.86 65.81 6,646.67
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Floor Beam
i) Ground Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
30 RA - 10 405.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,620.71 66.21 6,686.92
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Floor Beam
ii) First Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
31 RA - 10 405.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,660.56 66.61 6,727.17
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Floor Beam
iii) Second Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
32 RA - 10 405.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,700.41 67.00 6,767.41
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Floor Beam
iv) Third Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
33 RA - 10 405.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,740.26 67.40 6,807.66
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Floor Beam
v) Fourth Floor .
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
34 RA - 10 405.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,780.11 67.80 6,847.91
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Floor Beam
vi) Fifth Floor .
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
35 RA - 10 164.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,819.96 68.20 6,888.16
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Floor Beam
vii) SixthFloor .
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
36 RA - 11 69.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,777.07 57.77 5,834.84
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Lintel, sill and Mullians Bands
i) Ground Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
37 RA - 11 64.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,816.92 58.17 5,875.09
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Lintel, sill and Mullians Bands
ii) First Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
38 RA - 11 59.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,856.77 58.57 5,915.34
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Lintel, sill and Mullians Bands
iii) Second Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
39 RA - 11 52.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,896.62 58.97 5,955.59
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Lintel, sill and Mullians Bands
iv) Third Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
40 RA - 11 52.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,936.47 59.36 5,995.83
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Lintel, sill and Mullians Bands
v) Fourth Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
41 RA - 11 106.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,976.32 59.76 6,036.08
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Lintel, sill and Mullians Bands
vi) Fifth Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
42 RA - 11 22.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,016.17 60.16 6,076.33
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Lintel, sill and Mullians Bands
vii) Sixth Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
43 RA - 12 61.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,825.39 58.25 5,883.64
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Weathershed
i) Ground Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
44 RA - 12 53.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,865.24 58.65 5,923.89
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Weathershed
ii) First Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
45 RA - 12 53.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,905.09 59.05 5,964.14
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Weathershed
iii) Second Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
46 RA - 12 53.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,944.94 59.45 6,004.39
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Weathershed
iv) Third Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
47 RA - 12 53.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,984.79 59.85 6,044.64
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Weathershed
v) Fourth Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
48 RA - 12 53.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,024.64 60.25 6,084.89
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Weathershed
vi) Fifth Floor
Providing and laying in position control cement concrete mix M-25 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
49 RA - 12 23.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,064.49 60.64 6,125.13
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Weathershed
vii) SixthFloor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
all levels , heights upto 4.50m , excluding reinforcement .
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
51 RA - 14 380.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,973.75 59.74 6,033.49
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
i) Ground Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
52 RA - 14 372.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,013.60 60.14 6,073.74
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
ii) First Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
53 RA - 14 372.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,053.45 60.53 6,113.98
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
iii) Second Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
54 RA - 14 372.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,093.30 60.93 6,154.23
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
iv) Third Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
55 RA - 14 298.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,133.15 61.33 6,194.48
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
v) Fourth Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
56 RA - 14 298.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,173.00 61.73 6,234.73
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
vi) Fifth Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
57 RA - 14 36.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,212.85 62.13 6,274.98
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
vii) Sixth Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
58 RA - 15 15.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,856.39 58.56 5,914.95
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Stair Case
i) Ground Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
59 RA - 15 15.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,896.24 58.96 5,955.20
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Stair Case
ii) First Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
60 RA - 15 15.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,936.09 59.36 5,995.45
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Stair Case
iii) Second Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
61 RA - 15 15.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 5,975.94 59.76 6,035.70
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Stair Case
iv) Third Floor
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
62 RA - 15 15.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,015.79 60.16 6,075.95
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Stair Case
v) Fourth Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying in position control cement concrete mix M-30 grade for reinforced cement concrete work
using cement content as per approved design mix including pumping of concrete to site of laying, cost of Centering
shutterings, finishing, grouting if required , admixture in recommended proposition as per IS:9103 toaccelerated
retard, setting of concrete, improve workability as per direction of engineer in charge and approved , rates includes
63 RA - 15 15.00 all levels , heights upto 4.50m , excluding reinforcement . Cum 6,055.64 60.56 6,116.20
(No extra will be paid in variation of cement level, minimum cement level will be as per IS 456) for reinforced
concrete work in:
(C) RCC Stair Case
vi) Fifth Floor
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed
concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by
floating, brooming with wire brush including The panel shuttering work etc. complete As per drawings and design
supplied by architect and instruction given by authority and E.I.C.
Providing and laying High Density Reinforced Cement Concrete (HDRCC) of minimum density 2.5 g/cc or as specified
in approved radiation shielding design, using approved heavy aggregates such as Barytes / Magnetite and
incorporating boron carbide where required for neutron attenuation, in cyclotron bunker walls of any thickness,
height and level, including design mix minimum M40, mix design submission and approval, trial mixes to achieve
required strength and density, controlled weigh batching, mechanical mixing, transporting, placing in layers not
exceeding 500 mm lift, continuous vibration to achieve void-free homogeneous mass, finishing and curing complete.
The work shall be executed strictly using heavy duty steel tunnel formwork system (Outinord B8000 Evolution or
equivalent) with central lifting stability calliper, BAAM mechanical alignment devices, integrated working platforms,
guard rails, access ladders, stability struts and push-pull props, designed for concrete pressure as per CIRIA Report
108 and manufacturer’s guidelines, ensuring maximum admissible live load 4500 daN per stability calliper and lifting
angle limits as specified in manufacturer’s manual including assembling, alignment within ±1 mm tolerance,
controlled concreting speed to limit lateral pressure below 8 t/m², provision of magnetic stop-ends, cones, ties, and
sacrificial lining where required, safe cranage with minimum 4 m slings and 45° maximum sling angle, complete
stripping, cleaning and oiling of panels after each pour. The rate shall include continuous density testing, cube
testing, radiation shielding compliance testing, shuttering with tunnel technology formwork only, making and sealing
of all openings, penetrations and recesses to prevent radiation streaming, refilling and reinstatement with matching
high-density concrete, smooth internal finish suitable for epoxy coating, all leads and lifts, labour, plant and
machinery, safety systems, annual inspection and certified use of stability callipers, complete as per approved
structural drawings, approved radiation shielding design, IS 456, IS 10262, IS 1199, and AERB Safety Guide (latest
2025 edition), and as directed by Engineer-in-Charge.for RCC Wall
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying High Density Reinforced Cement Concrete (HDRCC) of minimum density 2.5 g/cc or as specified
in approved radiation shielding design, using approved heavy aggregates such as Barytes / Magnetite and
incorporating boron carbide where required for neutron attenuation, in cyclotron bunker walls of any thickness,
height and level, including design mix minimum M40, mix design submission and approval, trial mixes to achieve
required strength and density, controlled weigh batching, mechanical mixing, transporting, placing in layers not
exceeding 500 mm lift, continuous vibration to achieve void-free homogeneous mass, finishing and curing complete.
The work shall be executed strictly using heavy duty steel tunnel formwork system (Outinord B8000 Evolution or
equivalent) with central lifting stability calliper, BAAM mechanical alignment devices, integrated working platforms,
guard rails, access ladders, stability struts and push-pull props, designed for concrete pressure as per CIRIA Report
108 and manufacturer’s guidelines, ensuring maximum admissible live load 4500 daN per stability calliper and lifting
angle limits as specified in manufacturer’s manual including assembling, alignment within ±1 mm tolerance,
controlled concreting speed to limit lateral pressure below 8 t/m², provision of magnetic stop-ends, cones, ties, and
sacrificial lining where required, safe cranage with minimum 4 m slings and 45° maximum sling angle, complete
stripping, cleaning and oiling of panels after each pour. The rate shall include continuous density testing, cube
testing, radiation shielding compliance testing, shuttering with tunnel technology formwork only, making and sealing
of all openings, penetrations and recesses to prevent radiation streaming, refilling and reinstatement with matching
high-density concrete, smooth internal finish suitable for epoxy coating, all leads and lifts, labour, plant and
machinery, safety systems, annual inspection and certified use of stability callipers, complete as per approved
structural drawings, approved radiation shielding design, IS 456, IS 10262, IS 1199, and AERB Safety Guide (latest
2025 edition), and as directed by Engineer-in-Charge.for RCC Slab
Providing and laying High Density Reinforced Cement Concrete (HDRCC) of minimum density 2.5 g/cc or as specified
in approved radiation shielding design, using approved heavy aggregates such as Barytes / Magnetite and
incorporating boron carbide where required for neutron attenuation, in cyclotron bunker walls of any thickness,
height and level, including design mix minimum M40, mix design submission and approval, trial mixes to achieve
required strength and density, controlled weigh batching, mechanical mixing, transporting, placing in layers not
exceeding 500 mm lift, continuous vibration to achieve void-free homogeneous mass, finishing and curing complete.
The work shall be executed strictly using heavy duty steel tunnel formwork system (Outinord B8000 Evolution or
equivalent) with central lifting stability calliper, BAAM mechanical alignment devices, integrated working platforms,
guard rails, access ladders, stability struts and push-pull props, designed for concrete pressure as per CIRIA Report
108 and manufacturer’s guidelines, ensuring maximum admissible live load 4500 daN per stability calliper and lifting
angle limits as specified in manufacturer’s manual including assembling, alignment within ±1 mm tolerance,
controlled concreting speed to limit lateral pressure below 8 t/m², provision of magnetic stop-ends, cones, ties, and
sacrificial lining where required, safe cranage with minimum 4 m slings and 45° maximum sling angle, complete
stripping, cleaning and oiling of panels after each pour. The rate shall include continuous density testing, cube
testing, radiation shielding compliance testing, shuttering with tunnel technology formwork only, making and sealing
of all openings, penetrations and recesses to prevent radiation streaming, refilling and reinstatement with matching
high-density concrete, smooth internal finish suitable for epoxy coating, all leads and lifts, labour, plant and
machinery, safety systems, annual inspection and certified use of stability callipers, complete as per approved
structural drawings, approved radiation shielding design, IS 456, IS 10262, IS 1199, and AERB Safety Guide (latest
2025 edition), and as directed by Engineer-in-Charge.for RCC Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Chapter 05 Providing and laying TMT Bar FE-500D reinforcement for R.C.C. work and straightening, cutting, bending, binding &
68 05014C 1,812,376.00 placing in position completed upto all floor all level as per I.S. Standard. complete. As per drawings and design Kg 75.46 0.75 76.21
Page - 54 supplied by architect and instruction given by authority and E.I.C.
Providing and position PVC Sleeves in RCC elements like walls slabs beams etc. of 6 Kg/cm2 UPVC Pipes and
69 RA - 18 210.00 diameter of taking out service pipelines cables road infrasturcture work etc. upto 0.5 mtr. length for all floors/ all Each 42.90 0.43 43.33
levels / all heights. a) 50mm dia.
Chapter 06 Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in
72 06002BA 627.00 foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand) cum 3,981.21 39.81 4,021.02
Page - 71 (B) Conventional
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved
block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than
KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not
exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface with necessary tool
73 R.A-21 466.00 tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 cum 6,281.33 62.81 6,344.14
blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect
and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
a) Ground Floor
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved
block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than
KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not
exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface with necessary tool
74 R.A-21 474.00 tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 cum 6,321.42 63.21 6,384.63
blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect
and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved
block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than
KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not
exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface with necessary tool
75 R.A-21 763.00 tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 cum 6,361.51 63.62 6,425.13
blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect
and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
c) Second Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved
block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than
KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not
exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface with necessary tool
76 R.A-21 670.00 tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 cum 6,401.60 64.02 6,465.62
blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect
and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved
block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than
KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not
exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface with necessary tool
77 R.A-21 670.00 tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 cum 6,441.69 64.42 6,506.11
blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect
and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
e) Fourth Floor
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved
block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than
KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not
exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface with necessary tool
78 R.A-21 500.00 tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 cum 6,481.78 64.82 6,546.60
blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect
and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying autoclave aerated concrete blocks as per drawing in single or multiple layers with approved
block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block shall not be less than
KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not
exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface with necessary tool
79 R.A-21 198.00 tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 cum 6,521.87 65.22 6,587.09
blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding, racking / flush
jointing etc complete, as per drawing / specification etc, complete As per drawings and design supplied by architect
and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure works.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple
layers with approved Solid block laying polymer modified adhesive mortar. , minimum density in oven dry condition
between 2350 to 2450 KG/CUM, fire resistant 4 hours, in true line level and plumb and cleaning the surface with
80 R.A-22 413.00 necessary tool tackles including curing, scaffolding, racking / flush jointing etc complete, as per drawing / cum 7,588.01 75.88 7,663.89
specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
a) Ground Floor
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple
layers with approved Solid block laying polymer modified adhesive mortar. , minimum density in oven dry condition
between 2350 to 2450 KG/CUM, fire resistant 4 hours, in true line level and plumb and cleaning the surface with
81 R.A-22 371.00 necessary tool tackles including curing, scaffolding, racking / flush jointing etc complete, as per drawing / cum 7,628.10 76.28 7,704.38
specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple
layers with approved Solid block laying polymer modified adhesive mortar. , minimum density in oven dry condition
between 2350 to 2450 KG/CUM, fire resistant 4 hours, in true line level and plumb and cleaning the surface with
82 R.A-22 81.00 necessary tool tackles including curing, scaffolding, racking / flush jointing etc complete, as per drawing / cum 7,668.19 76.68 7,744.87
specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
c) Second Floor
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple
layers with approved Solid block laying polymer modified adhesive mortar. , minimum density in oven dry condition
between 2350 to 2450 KG/CUM, fire resistant 4 hours, in true line level and plumb and cleaning the surface with
83 R.A-22 74.00 necessary tool tackles including curing, scaffolding, racking / flush jointing etc complete, as per drawing / cum 7,708.28 77.08 7,785.36
specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple
layers with approved Solid block laying polymer modified adhesive mortar. , minimum density in oven dry condition
between 2350 to 2450 KG/CUM, fire resistant 4 hours, in true line level and plumb and cleaning the surface with
84 R.A-22 74.00 necessary tool tackles including curing, scaffolding, racking / flush jointing etc complete, as per drawing / cum 7,748.37 77.48 7,825.85
specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
e) Fourth Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying Solid Concrete Blocks (400 x 230/300 x 150/200 mm) or as per drawing in single or multiple
layers with approved Solid block laying polymer modified adhesive mortar. , minimum density in oven dry condition
between 2350 to 2450 KG/CUM, fire resistant 4 hours, in true line level and plumb and cleaning the surface with
85 R.A-22 939.00 necessary tool tackles including curing, scaffolding, racking / flush jointing etc complete, as per drawing / cum 7,788.46 77.88 7,866.34
specification etc, complete As per drawings and design supplied by architect and instruction given by authority and
E.I.C. For all civil, plumbing, electrical & infrastructure works.
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple
layers with approved block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block
shall not be less than 40 KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface
with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding,
racking / flush jointing etc complete, as per drawing / specification etc, complete As per drawings and design
supplied by architect and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure
a) Ground Floor
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple
layers with approved block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block
shall not be less than 40 KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface
with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding,
racking / flush jointing etc complete, as per drawing / specification etc, complete As per drawings and design
supplied by architect and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple
layers with approved block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block
shall not be less than 40 KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface
with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding,
racking / flush jointing etc complete, as per drawing / specification etc, complete As per drawings and design
supplied by architect and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure
c) Second Floor
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple
layers with approved block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block
shall not be less than 40 KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface
with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding,
racking / flush jointing etc complete, as per drawing / specification etc, complete As per drawings and design
supplied by architect and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple
layers with Ready mix joining mortar. Crushing strength of aerated concrete block shall not be less than 40 KG/sqcm,
minimum density in oven dry condition between 651 to 750 KG/CUM, thermal conductivity shall not exceed
w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface with necessary tool tackles, The
drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and 0.10 percent for Grade 2 blocks when
tested in accordance with IS : 6641 (Part-2)-1972 etc. at all floors, any heights, all depths, any levels (in foundation &
Superstructure) and all places including curing, scaffolding, racking / flush jointing etc complete, As per drawings and
design supplied by architect and instruction given by authority and E.I.C. For all civil, plumbing, electrical &
infrastructure works.
e) Fourth Floor
Providing and laying autoclave aerated concrete blocks as per drawing (Thickness 100 mm ) in single or multiple
layers with approved block laying polymer modified adhesive mortar. Crushing strength of aerated concrete block
shall not be less than 40 KG/sqcm, minimum density in oven dry condition between 651 to 750 KG/CUM, thermal
conductivity shall not exceed 0.30 w/mk, fire resistant 4 hours, in true line level and plumb and cleaning the surface
with necessary tool tackles The drying shrinkage shall be not more than 0.05 percent for Grade 1 blocks and
percent for Grade 2 blocks when tested in accordance with IS : 6641 (Part-2)-1972 etc. including curing, scaffolding,
racking / flush jointing etc complete, as per drawing / specification etc, complete As per drawings and design
supplied by architect and instruction given by authority and E.I.C. For all civil, plumbing, electrical & infrastructure
Chapter 17 Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level
92 17001A+17006 2,801.00 and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 152.15 1.52 153.67
Page - 136, 137 A) Ground Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level
93 2,073.00 and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 175.31 1.75 177.06
B) First Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level
94 2,350.00 and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 198.47 1.98 200.45
C) Second Floor (For Ceiling, Beam bottom and sides)
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level
95 2,403.00 and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 221.63 2.22 223.85
D) Third Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level
96 2,403.00 and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 244.79 2.45 247.24
E) Fourth Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level
97 2,433.00 and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 267.95 2.68 270.63
F) Fifth Floor (For Ceiling, Beam bottom and sides)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level
98 314.00 and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) Sqm 291.11 2.91 294.02
G) Sixth Floor (For Ceiling, Beam bottom and sides)
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior
99 17002A 7,459.00 plastering upto floor two level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 174.83 1.75 176.58
Page - 136 A) Ground Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior
100 17002A+17007A 5,191.00 plastering upto floor two level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 197.99 1.98 199.97
Page - 136, 137 B) First Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior
101 17002A+17007A 4,748.00 plastering upto floor two level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 221.15 2.21 223.36
Page - 136, 137 C) Second Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior
102 17002A+17007A 3,949.00 plastering upto floor two level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 244.31 2.44 246.75
Page - 136, 137 D) Third Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior
103 17002A+17007A 3,792.00 plastering upto floor two level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 267.47 2.67 270.14
Page - 136, 137 E) Fourth Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior
104 17002A+17007A 5,959.00 plastering upto floor two level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 290.63 2.91 293.54
Page - 136, 137 F) Fifth Floor (For inside wall, verticle surface plaster )
Chapter 17 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior
105 17002A+17007A 407.00 plastering upto floor two level and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) Sqm 313.79 3.14 316.93
Page - 136, 137 G) Sixth Floor (For inside wall, verticle surface plaster )
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing 20 mm thick double coat mala cement plaster on interior brick / concrete work for plastering comprising of
base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm
thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including scaffolding curing etc.
Chapter 17 Providing & laying 20 mm. thick sand face cement plaster Gutkha finish on walls up to 10mt. height and above
107 17009 843.00 ground level consisting of 12 mm. thick backing coating of C.M. 1:3 (1 cement : 3 sand) and 8 mm. thick finishing Sqm 297.68 2.98 300.66
Page - 137 coat in C.M. 1:1 (1 cement :1 sand) etc. complete.
Providing and fixing Chicken wire mesh jali 16 x 24 or approved size of 22 gauge at junction of concrete and brick
work / AAC Block work or between different materials after making "V" grove between two different material surface
and filled with rich cement mortar, nailing etc complete for all floor, any height, all shape etc complete As per
drawings and design supplied by architect and instruction given by authority and E.I.C..
Providing and applying medium grain textured exterior finish, siloxane modified acrylic based, anti-mould, anti-algae,
weather resistant, water based coating system of approved imported make, of selected marble chip texture and
approved shade as per 3D architectural drawings, applied over properly prepared substrate including surface
cleaning, crack filling, surface levelling with exterior grade putty where required, application of suitable exterior
109 R.A-25 5,418.00 primer, followed by application of textured coating in required thickness and pattern using spray / trowel as per Sqm 1,405.00 14.05 1,419.05
manufacturer’s specification, ensuring uniform grain distribution and finish, including final protective top coat where
specified, complete with all scaffolding, labour, materials, T&P, lead and lift at all heights, curing, protection and
cleaning, complete in all respects as per approved drawings, manufacturer’s specifications and directions of Architect
/ Engineer-in-Charge for all height. basic rate of texure 80 rs per sqft.
Chapter 18 Providing and applying Wall painting (three coats) with plastic emulsion paint of approved brand and manufacture
110 18031+18032 30,721.00 on under coated wall surface to give and even shade including throughly brushing the surface free from mortor Sqm 111.83 1.12 112.95
Page - 143 droppings and other foreign matter and sand paperd smooth on new work to give an even shade.for all height
Chapter 19 Finishing wall with weather proof low viscosity ultima exterior emulsion paint on wall surface (two coats) to give an
111 19031 8,843.00 required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered Sqm 113.40 1.13 114.53
Page - 140 materials.etc complete for all height
Chapter 19 Applying two coats of acrylic lapy ( putty) & two coats of primer of approved brand and manufacture on new wall
112 19032 30,721.00 surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other Sqm 40.19 0.40 40.59
Page - 141 foreign matter and sand papered smooth.
Providing cement vata (10 cm x 10 cm size) quarter round in cement mortar 1:1 including neat cement finishing,
watering etc. complete.For all floor
114 5018 3,848.00 Providing throating or plaster drip and moulding to R.C.C. Chhajja. Rmt 41.25 0.41 41.66
Providing & applying two Componant , non slumping , non-sagging, thixotropic epoxy bedding compond &
adhesive compatible with for tiles for coving at radius of 25 mm or as directed by the architect's/Engineer-in-charge
115 R.A-26 7177.00 make it fit for tiles inclusive of Labour, material and Equipment etc. for all heights ,location, shape & size as directed Rmt 450.01 4.50 454.51
by the architect/ engineer incharge etc completed As per drawings and design supplied by architect and instruction
given by authority and E.I.C. (Actual Length shall be measured for payment.)
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Metallic Wall Panels & Walkalbe Ceiling Panels
Providing, Designing, Supplying, Fabricating, and Installing of Metallic Wall Panels, Walkable Ceiling Panels, and
Integrated Partition Systems of proven quality and performance. All panels shall be high quality, tough, durable, and
impact resistant, with a factory pre-painted smooth finish. The painted surfaces shall be resistant to cleaning agents
and suitable for frequent washing without any deterioration, discoloration, or loss of finish. All materials used shall be
rust-proof, corrosion-resistant, and inert to the development of micro-organisms. Wall and ceiling surfaces shall
neither emit nor retain particles of any nature, ensuring hygienic conditions. The surfaces shall be easy to clean and
washable on a regular basis without affecting the paint or surface integrity. The complete partition system shall be
fully waterproof and watertight, including all panel joints. The system shall consist of metal composite panels of
mm overall thickness with PUFF core density adequate to provide structural stability, strength, and effective thermal
insulation. The minimum metal sheet thickness shall be 0.65 mm to 0.70 mm, with sheets pre-painted on all sides. All
panel joints shall be rigorously sealed and watertight. Return air risers shall be integrated within the wall system,
provided flush with wall thickness, using panels of 0.65 mm to 0.70 mm thickness on both sides, pre-painted
throughout, and matching the ceiling panel material and paint quality. Filters, light fittings, air extract grills, and
outward-opening access traps shall be flush-mounted. The walkable ceiling shall include a galvanized suspension
system as a standard feature. Aluminium or PU coving shall be provided at wall-to-ceiling junctions, and panels shall
Providing and applying a single-component, waterborne modified polyurethane (PU) dispersion-based wall coating
system, designed for interior wall surfaces, complete as per manufacturer’s recommendations and technical data. The
coating shall deliver a durable, hygienic, and semi-gloss finish with a minimum dry film thickness of 120 microns. The
system shall consist of surface preparation, priming, and application of PU top coats to achieve the specified
performance and appearance. Surface preparation shall ensure the substrate is clean, dry, sound, and free from dust,
oil, grease, and loose particles. Priming shall be carried out as required, with an approximate material consumption
of 0.15–0.20 kg/m², ensuring uniform coverage and proper adhesion to the substrate. The PU top coat shall be
applied in two coats, each with a material consumption of approximately 0.10–0.12 kg/m² per coat, achieving a total
system thickness of 120 microns. Additional material shall be allowed to account for surface porosity, surface profile,
level variations, and application wastage. Application shall be carried out under controlled environmental conditions,
with ambient and substrate temperatures maintained between +15°C (minimum) and +30°C (maximum), and relative
air humidity not exceeding 80%. The substrate temperature shall be at least 3°C above the dew point to prevent
condensation and blooming of the coating. Substrate moisture content shall be visibly damp-free, with a maximum
of 18% wood moisture equivalent, and no rising moisture as per ASTM polyethylene sheet test. Overcoating intervals
shall be approximately 8 hours minimum at +20°C and 6 hours minimum at +30°C, with a maximum overcoating
window of 48 hours. All application times are approximate and subject to ambient temperature and humidity
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing 1200 mm height aluminium powder coated railing with frosted/clear toughened glass panels,
comprising aluminium framework of approved section and design, powder coated in approved colour and finish,
including 12 mm thick frosted/clear toughened safety glass panels, edges polished and free from defects, fixed
between aluminium members, consisting of top and bottom rails of size 50 mm × 25 mm aluminium section, vertical
posts of size 50 mm × 50 mm aluminium section spaced at maximum 1200 mm centre to centre, powder coated
glass clamps suitable for 12 mm glass, base plate of size 100 mm × 100 mm × 6 mm thick securely anchored to RCC
118 R.A-28 234.00 / structural member using anchor bolts and chemical fasteners, including rail brackets and necessary fixing Rmt 6,670.00 66.70 6,736.70
accessories, installation of glass panels with clamps, proper alignment, plumbing and levelling, sealing joints with
approved silicone sealant, ensuring smooth powder coated finish, scratch free frosted glass surface, structural
stability and safety compliance as per relevant standards and codes, including all labour, materials, hardware, T&P,
lead and lift, scaffolding, wastage and incidentals, complete in all respects as per approved drawings, specifications
and directions of Architect / Engineer-in-Charge.
Providing and fixing aluminium powder coated hand railing system, comprising 50 mm diameter top rail with
intermediate supports of 37.5 mm diameter placed at maximum 1.00 metre centre to centre, installed along staircase
waist slab side walls and over ramp parapet walls, including fabrication, welding, grinding, buffing, polishing and
forming required curvature wherever specified in drawings, complete with balusters, brackets, supports, horizontal
119 R.A-29 95.00 members, base plates and all necessary fixing accessories, nuts, bolts and fasteners, properly anchored to RCC / Rmt 1,513.52 15.14 1,528.65
masonry substrate with suitable mechanical / chemical fasteners, ensuring correct alignment, level and structural
stability, smooth powder coated finish free from dents and scratches, including all labour, materials, T&P, scaffolding,
lead and lift, wastage and incidentals, complete in all respects as per approved drawings, specifications and
directions of Architect / Engineer-in-Charge.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory
windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium
carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum oxicity index
of 12 for 100 gms) fabricated with miter joints after star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2,
modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being
120 R.A-30 725.00 termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash Rmt 832.95 8.33 841.28
fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash
fasteners shall be including). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth
and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra
payment on this account shall be made. applying PVC solvent cement and screwed with full body threaded Complete
As per drawings and design supplied by architect and instruction given by authority and E.I.C.
1) Frame size 45 x 85 mm
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color
and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot
melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin
polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat
husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum
and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2,
modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being
termite/ borer proof,water/moisture proof and fire retardant including stainless steel piano hinges/soft close clip on
concealed hinges and necessary S.S screws, stainless steel butt hinges of required size with necessary full body
threaded star headed counter sunk S.S screws, Handles, Stopper, Door closer, Tower bolt all As per drawings and
design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing of Anodised Aluminium (Matt finish) frame work (Horizontal and verticals , Styles and rails, ball
bearing) for Doors/ window/ventilation/alluminum partition with required Domal sections including fixing all items
and hinged / pivoted arrangements for operation of shutters and labour cost for fixing of door fittings and locks
including all items and contingencies described above complete (Aluminium beadings and glazing clips & section
measured under this item only) NOTE: All fitting works shall be carried out as per I.S. specifications including cost of
necessary rivets, screws, lugs, scaffolding, rubber gaskets etc., complete all generally as per drawings. The sizes of the
components should confirm as per details in drawings. Providing and fixing at all heights / in all floors with all leads.
Colour Anodised Aluminium doors / windows / partitions manufactured from best extruded Aluminium sections
confirming to ISI cut to length, joints mitred and corners grinded with joints water proof the outer frame and shutter
122 R.A-32 7,822.00 frame stiffened with corner angle and strips provided for in the frame for fixing the frame to R.C.C Columns / Kg 366.44 3.66 370.10
masonry/Granite Frame on sides, R.C.C lintels/Granite Frame on top and P.C.C sills or floor at bottom, the frame work
fixed with standard approved fastenings all generally as per details shown in drawings and specification with all the
sections pretreated for removal of any rust & scales and prevention of further rust/scale formation and coated with
greasy materials for non-adherence of mortar or any other sticky materials and this coat to be removed after
installations 1)Sheet metal screws, wool pile and aluminium angle corner cleat of required thickness and of full width,
etc. for assembling the frame and shutter; 2)Glazing clips for receiving infill panel for Double Glazed Unit (DGU), any
type of Glass, Compact Sheet, Louvers; 3) Best quality wool pile where ever shutter touches the frame; 4) Anchor
fasteners for fixing the frame assembly to the RCC or Granite or masonry surfaces etc. complete.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing frosted glass /Texture Glass of any size, any shape and specified thickness in frame and shutter
work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality
rubber/silicon sealant/structural sealant of 3M tape on the periphery of the glass as per the required thickness etc.
complete a tall floors/alllevels/all heights as per the directions of Architect. Actual installed quantity shall be
measured and paid. Rate shall be inclusive of all type of wastage. etc, completed as per drawings and design
supplied by architect and instruction given by authority and E.I.C.(a) 6 mm thick
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing Tinted Float Glass of any size, any shape and specified thickness and SHGC velue 25 % in frame
and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM
quality rubber/silicon sealant/structural sealant 3M tape on the periphery of the glass as per the required thickness
etc. complete a tall floors/alllevels/all heights As per drawings and design supplied by architect and instruction given
by authority and E.I.C.. Actual installed quantity shall be measured and paid. Rate shall be inclusive of all type of
wastage. (a) 5 mm thick
Providing and fixing Compact Sheet of dark maroon colour in aluminium frame and shutter work with necessary
cutting of sheet, single side, double side coloured as per drawing & specifications including providing and fixing
EPDM quality rubber/silicon sealant/3M tape/screwing on the periphery of the sheet as per the required thickness
etc. complete at all floors/all levels/all heights As per drawings and design supplied by architect and instruction given
by authority and E.I.C. Cut edges of the compact sheet shall be provided with masking tape. Actual installed quantity
shall be measured and paid. Rate shall be inclusive of all type of wastage.(a) 6 mm thick
General Notes for Hardware : Supplying and fixing heavy quality fixture sand fittings for doors, windows, ventilators,
partition wall, cabinets with necessary screws, nails, machine pins etc. at all floor/all levels/all heights complete. The
126 R.A-36 231.00 fittings and fixtures hardware . The fixture & fastenings shall be provided as under : Providing & fixing heavy Nos. 1,600.00 16.00 1,616.00
duty"Euro profile Mortise Dead lock"(12.6cm 1CK brass)with minimum 6keys in door/window with necessary screws
and as per drawing, complete.
Providing & fixing SS 304 grade Baby latch" Door Bolt" size of 3.5"with hair line finish with necessary S.S. Screws
127 R.A-37 114.00 sand as per drawing, complete As per drawings and design supplied by architect and instruction given by authority Nos. 250.00 2.50 252.50
Providing & fixing heavy quality SS AISI 316 grade "Butt Hinge with 4 Bearing"of 102 x 76 x 3mm with necessary S.S.
128 R.A-38 12.00 Screws and as per drawing, complete As per drawings and design supplied by architect and instruction given by Nos. 500.00 5.00 505.00
authority and E.I.C.
Providing, supplying, fixing and installation of Aluminium DGU Sliding Window made from Domal series sections
comprising 3-Track frame section (21376) of size 80 × 45 × 1.5 mm and shutter section (21967) of size 67.4 × 27 ×
1.8 mm, fitted with Double Glazed Unit (DGU) clear glass of 6 mm + 12 mm air gap + 6 mm, complete with approved
colour anodized finish on aluminium profiles, including all required accessories such as rollers, handles, interlocks,
gaskets, wool pile, screws, fasteners and necessary fittings, including cutting, fabrication, glazing, assembling and
installation at site, complete in all respects as per approved drawings and specifications.The work shall include
proper sealing between frame and structure to prevent air and water infiltration. The entire work shall be executed as
per approved drawings, specifications and directions of the Engineer-in-Charge, complete in all respects, and the rate
shall include all materials, labour, tools, plant, machinery and incidentals necessary for satisfactory completion of the
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing, supplying, fixing and installation of Aluminium DGU Fixed Window fabricated from Domal series
aluminium sections comprising Outer Frame Section (14011) size 25.80 × 25.40 × 1.5 mm along with Fixing Square
Pipe Section (14470) size 25 × 25 × 1.5 mm, designed to accommodate Double Glazed Unit (DGU) clear glass of
mm + 12 mm air gap + 6 mm, with approved colour anodized finish on aluminium profiles, including all required
accessories such as EPDM gaskets, beading, screws, fasteners and necessary fittings, including cutting, fabrication,
glazing, assembling and installation at site, complete in all respects as per approved drawings and specifications.The
work shall include proper sealing between frame and structure to prevent air and water infiltration. The entire work
shall be executed as per approved drawings, specifications and directions of the Engineer-in-Charge, complete in all
respects, and the rate shall include all materials, labour, tools, plant, machinery and incidentals necessary for
satisfactory completion of the work.
Providing, supplying, fixing and installation of aluminium DGU Openable Window fabricated from Domal series
aluminium sections comprising Outer Frame Section (21635) size 52 × 44.5 × 1.4 mm, Shutter Section (21636) size
× 66 × 1.4 mm, and Fixing Clip (19469) size 32 × 26 × 1.2 mm, fitted with Double Glazed Unit (DGU) clear glass of
mm + 8 mm air gap + 6 mm, with approved colour anodized finish on aluminium sections, including all required
accessories such as hinges, handles, EPDM gaskets, screws, fasteners and necessary fittings, including cutting,
fabrication, glazing, assembling and installation at site, complete in all respects as per approved drawings and
specifications.The work shall include proper sealing between frame and structure to prevent air and water infiltration.
The entire work shall be executed as per approved drawings, specifications and directions of the Engineer-in-Charge,
complete in all respects, and the rate shall include all materials, labour, tools, plant, machinery and incidentals
necessary for satisfactory completion of the work.
Providing & fixing SS 316 Medium Duty Hydraulic Floor Spring for 80to130KG with cover plate & adjustable
concealed casted top pivot of any color with necessary screws and as per drawing,complete as approved by
132 R.A-41 78.00 Architect. Rate shall be inclusive of cutting off loor neatly, grouting the floor spring & cleaning/ polishing the floor & Nos. 5,000.00 50.00 5,050.00
maintaining in good working condition till defect liability period with one year guarantee.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing & fixing SS 304 grade of brush/satin finish specified size Tower Bolt with necessary screws and as per
133 R.A-42 292.00 drawing, complete As per drawings and design supplied by architect and instruction given by authority and E.I.C. Nos. 850.00 8.50 858.50
a) 18" x 10mm (square)
Providing & fixing SS AISI 316 grade of glossy/satin finish specified size Push-Pull Handle in pairs with necessary
screws and as per drawing, complete Note:-As per drawings and design supplied by architect and instruction given
by authority and E.I.C.
a) 22mm (diameter) x 300mm
Providing and Fixing heavy duty S.S. Door Closer As per drawings and design supplied by architect and instruction
given by authority and E.I.C.
Providing and fixing Stainless steel mosquito net jali ,wire of I.S gauge designation 85-G with wire of 0.56 mm fix in
aluminium door, window, ventilator shutters of any size, any shape with etc all complete at all floors/all levels/all
heights As per drawings and design supplied by architect and instruction given by authority and E.I.C. Actual laying
installed Jali shall be measured. (Cost of aluminium snap beading shall be paid in basic item)
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing M.S. grill of required pattern top wooden frames of windows etc. with M.S.. flats at required
spacing and frame alround square or round headed bolts and nuts or by screws.including applying a priming coat of
red lead paint and two coats of oil painting etc complete (A)Plain grill
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing Flush type cleanroom Doors made up of 0.6 mm thick PPGI sheet, Door leaf 45mm thick, and
door frame of 1.2mm thick G I sheet, with The Shutter & Frame Shall be fully lead lined of min of 5 MM lead Sheet
with 99% purity and as defined by AERB. All provision should be mortised, drilled and tapped for receiving
appropriate hardware , with PUF insulation as infill material with Polyester Powder Coated finish with Hardware like
Dead lock, SS D Type handle Back to back / SS D Handle one side and one side SS push plate, Automatic Spring
Operated Consealed drop seal, Door Closer,SS Ball Bearing Hinges-100X58X3 mm,SS Kick Plate-Up to 300 mm
height, Vision Panel in door 350x750mm. Double Door/Single Door 2400X2400 mm Note:-As per drawings and
design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing of approved make Trap door with galvanised steel.Doors should be finished in Powder Coating
with film thickness of 60 microns approx. in desired RAL Shades. The manufacturer company must be TUV Nord ISO
9001-2015 certified ACODOR (koleshvari Infra) trap door and must be made from galvanised steel sheet. door must
be concealed type of hinges and appropriate provision for hanging from celling. appropriate locking must be
provided.frame and door must made from minimum 1 mm glavanised steel.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Designing, Providing & fixing glass work at entrance having glass panels including 4 openable , central and fixed
side panels. Assembly shall be made of 12 mm clear heat strengthened glass of approved colour, frameless door
shutter with approved floor springs & patch fittings, to support / hold glass to withstand wind pressure of
140 R.A-49 25.00 kg/Sqm, stainless steel handles 430mm x 30mm (S.S.S min), patch locks, joints should be filled with transparant Sqm 6,019.10 60.19 6,079.29
approved silicon sealant to ensure stability & water tightness of door including fine stoppage including approved
heavy duty bottom rail / door section of anodized Aluminum sections etc.as per specification , approved approved
drawings and As per drawings and design supplied by architect and instruction given by authority and E.I.C.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Supply and fixing Wooden lead lined door frame for Single /Double leaf to required sizes of The frame should be
Single rebate profile of size 120 x 70 mm made out of Hardwood Mirandi. Frames shall be Butt jointed and field
assembled with self tabs. The Shutter & Frame Shall be fully lead lined of min of 3 MM lead Sheet with 99% purity
and as defined by AERB. All provision should be mortised, drilled and tapped for receiving appropriate hardware.
Rubber door silencers should be provided on the striking jamb. Frames should be fixed by anchor fasteners for
installation on a finished plastered masonry wall opening fixed in existing opening with the help of anchor fastener
of appropriate size as per direction of Engineer in Charge. The manufacturer should be an ISO certified and IGBC
registered member.Providing and fixing wooden Leadline Door leaf 44 mm thick with commercial ply & laminate
both side with or without vision lite.incase vision lite is required it shall be only Lead Glass as recomomnded by
141 R.A-50 465.00 AERB/DRC . The internal construction of the door should be rigid with lead line of 2mm thick all across the inside of Sqm 45,000.00 450.00 45,450.00
the exposed surface. In addition the door should have a basic infill ROCK WOOL with necessary reinforcement both
on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with
necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. including Providing and fixing SS
Ball Bearing Hinges of size 100 x 75 x 3mm complete with SS Screws ( 4 Nos. per panel ), Mortise Dead Lock, SS D
Type Pull Handle of size 300mm mm Long, door closers, Stainless Steel 304 grade 300mm Long Tower Bolt, anchor
fasteners of maximum 120mm lengths etc complete As per drawings and design supplied by architect and
instruction given by authority and E.I.C.
Providing and fixing Structural Glazing with using the 17 Micron anodised of approved colour alluminium section as
transium, mullium of size 63.5mm x 38.1mm x 2 mm with using 6 mm thick reflective structural glass (including
142 R.A-51 2,708.00 toughning) and fixed with silicone sealant and spacer tap and at corner sealed neoprene foam dust and Air sealed Sqm 4,155.75 41.56 4,197.31
gasket mirred including scaffolding etc.complete with all necessary fitting and fixtures including openable window.
etc complete as per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing in position collapsible steel shutters with vertival channels 20 mm x 10 mm x 2 mm braced with
Chapter 11 flat iron diagonals 20 mm x 5 mm size with top & bottom rails of T iron 40 mm x 40 mm x 6 mm with 38 mm
143 11003A 16.00 diameter steel pulleys complete with bolts, nuts, locking arrangements, stopper handles including applying a priming Sqm 5,391.23 53.91 5,445.14
Page - 110 coat of red lead paint.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing, supplying, preparing, and installing a complete high-performance cementitious polyurethane (PU) Clean
Room Flooring System with a nominal thickness of 4.0 mm, including all materials, labor, equipment, surface
preparation, priming, scratch coating, PU floor topping, coving, joint treatment, curing, testing, and all incidental
works, complete in all respects and in strict accordance with the manufacturer’s instructions, applicable standards,
and clean room requirements. The flooring system shall be designed for the highest order of durability, offering
excellent resistance to abrasion, chemical attack, impact, and physical aggression, and shall be anti-bacterial, anti-
fungal, UV resistant, seamless, hygienic, non-dusting, and suitable for frequent washing and use of approved clean
room cleaning agents, providing a smooth matt, impervious, and easy-to-clean finish. All horizontal and vertical
corners, wall-to-floor junctions, upstands, columns, and similar details shall be finished with same-color polyurethane
coving to eliminate dirt traps. Substrate preparation shall include mechanical removal of laitance, curing membranes,
sealers, dust, oil, grease, paint, plaster, corrosion deposits, algae, and all unsound or contaminated materials by shot-
blasting, grinding, or light scrabbling to expose sound concrete, followed by thorough vacuum cleaning. New
concrete substrates shall be minimum RC30 grade as per BS 8500-2:2002, free from water-repellent admixtures,
achieving a rebound hammer value above 25 or surface tensile strength exceeding 1.5 MPa, and ground-bearing
slabs shall include a damp-proof membrane in accordance with CP102. Existing concrete floors shall be similarly
prepared, with oil and grease contamination removed by mechanical, steam, biological, or high-pressure water
methods, repaired where defective, and provided with surface-applied membranes or pressure-relief measures where
hydrostatic pressure is anticipated. A cementitious PU scratch coat of approximately 1.0 mm shall be applied to
prime and seal the substrate and cured for 12–48 hours, followed by a flow-applied cementitious PU topping of
mm, mixed using a forced-action mixer and achieving specified Compressive Strength (ASTM CI09) (28 days –
MPa), Tensile Strength (BS6319-7) (28 days – 6.8 MPa), Flexural Strength (BS6319-3) (28 days – 17.9 MPa), Slip-
Resistance (ASTM E303) Dry, and impact-resistance(ASTM 02794), Joules for 3mm thickness (8.1) & 6mm thickness
(10.8) with anchorage grooves formed at edges, joints, drains, and doorways. Priming shall be carried out using two-
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with
water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and
shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3
kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the
145 R.A-53 1,027.00 zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required Sqm 1,444.73 14.45 1,459.18
thickness, leveling system and rubber mallet for placing the tiles gently and easily including grouting the joints with
white cement and matching pigments etc., complete. Colour and shade as approved by architect. All joints filled with
epoxy grout (avg. 4*10 to12 mm).Rate includes for all lead & lift . Glazed vitrified floor tiles polished finish of size
1200 X 1200 mm For Light Shade.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with
water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and
shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3
kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the
146 R.A-54 514.00 zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required Sqm 1,525.24 15.25 1,540.49
thickness, leveling system and rubber mallet for placing the tiles gently and easily including grouting the joints with
white cement and matching pigments etc., complete. Colour and shade as approved by architect. All joints filled with
epoxy grout (avg. 4*10 to12 mm).Rate includes for all lead & lift . Glazed vitrified floor tiles polished finish of size
1200 X 1200 mm For Dark Shade.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying 25 mm thick premium grade, machine cut, mirror polished Kota stone slabs of size 600 ×
mm, uniform in colour, texture and density, free from cracks, veins and surface defects, in flooring, skirting, risers,
steps and dado, laid over 20 mm average thick cement mortar bed (1:6) (1 cement : 6 coarse sand), including
cleaning, wetting of base, cement slurry bonding coat, proper bedding, leveling, alignment and compaction
complete, machine grinding with multi stage diamond pads, final mirror polishing to achieve smooth, even, high
gloss finish, chamfered edges, proper curing, surface protection, cutting and fitting around columns, frames and
fixtures, including all labour, materials, T&P, lead and lift, wastage and incidentals, complete as per drawings,
specifications and directions of Engineer-in-Charge.
Providing and laying 600 × 600 mm ultra-premium full body glazed vitrified tiles, rectified edges, uniform thickness
(minimum 8–10 mm), water absorption less than 0.5%, high gloss / satin finish as approved, in dado work on walls,
fixed using high performance polymer modified tile adhesive (C2TE/S1 grade or equivalent) of approved make,
applied with notched trowel over properly prepared, levelled, cleaned and primed surface, including surface hacking /
roughening wherever required, maintaining uniform 4 mm wide joints using spacers, ensuring proper alignment,
148 R.A-56 17,876.00 plumb, line and level, cutting and fitting around corners, edges, openings and fixtures, back buttering of tiles where Sqm 1,664.00 16.64 1,680.64
necessary to avoid hollowness, filling joints with approved stain resistant epoxy grout of matching shade, removal of
excess grout, final cleaning with non-acidic solution, curing and protection of finished surface, including all labour,
materials, T&P, scaffolding, lead and lift, wastage and incidentals, complete in all respects as per approved drawings,
specifications and directions of Architect / Engineer-in-Charge.
Providing and fixing 19 mm thick × 65 mm wide round moulded “Telephone Black” granite pencil patti with bevelled
edge finish, machine cut and mirror polished, uniform in shade and texture, free from cracks and surface defects,
fixed over top edge of vitrified tile dado as shown in drawings, bonded using high performance polymer modified
tile/stone adhesive (C2TE/S1 grade or equivalent approved make) over properly prepared, cleaned and levelled
substrate, including back buttering of granite where required to ensure full contact and avoid hollowness, proper
alignment, line and level, cutting and finishing at corners and junctions, filling all joints with approved colour
matched epoxy grout, finishing with sharp flush joints, cleaning excess grout, final surface cleaning with non-acidic
solution, curing and protection, including all labour, materials, T&P, scaffolding, lead and lift, wastage and
incidentals, complete in all respects as per approved drawings, architectural details and directions of Authority /
Engineer-in-Charge.
Providing and laying full body vitrified anti-skid tiles, 8–10 mm thick, size 600 × 600 mm, rectified edges, water
absorption less than 0.5%, uniform in colour and shade as approved by Architect, in flooring, laid over 20 mm
average thick cement mortar bed (1:6) (1 cement : 6 coarse sand) or levelling mortar 1:1.5 as specified, on new
surface, including preparation, cleaning and wetting of base, cement slurry bonding coat, proper bedding, alignment,
levelling and compaction complete after dismantling and removal of existing flooring including disposal of debris as
directed, maintaining uniform joints of 4 mm width using spacers, filling joints with approved colour matched epoxy
grout (average 4 mm × 10–12 mm), finishing with flush pointing, removal of excess grout, final cleaning without acid
damage, curing and protection of finished surface, including all labour, materials, T&P, lead and lift, wastage and
incidentals, complete in all respects as per approved drawings, specifications and directions of Authority / Engineer-
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying 18 mm thick premium quality Italian marble slabs, machine cut, calibrated, mirror polished,
uniform in colour, grain and texture, free from cracks, pits, resin patches and visible defects, laid in required pattern
in linear portions of the building as per approved architectural drawings, over 20 mm average thick cement mortar
bed (1:4) (1 cement : 4 coarse sand), including preparation, cleaning and wetting of base, cement slurry bonding
coat, proper bedding, alignment, levelling and compaction complete, jointed with white cement slurry @ 4.4 kg per
Sq.m, joints finished with white cement slurry admixed with matching pigment to achieve seamless appearance,
machine grinding, multi-stage rubbing and mirror polishing, edge dressing, cutting and fitting around columns,
frames and fixtures, curing, surface protection and final cleaning without acid damage, including all labour, materials,
T&P, lead and lift, wastage and incidentals, complete in all respects as per approved drawings, specifications and
directions of Authority / Engineer-in-Charge
Providing & laying average 40mm-100mm thick wired finish/float finish screed of cement concrete 1;2;4 ( 1 cement :
2 coarse sand : 4 graded stone agreegate 20 mm nominal size ) as base material for any type of flooring works in
152 R.A-61 1,229.00 building, general development area works etc. laid to achieve proper slope or 0-0 levelled surface and curing cum 1,831.30 18.31 1,849.61
complete excluding cost of formwork at any type of surface ,all floors ,all levels, all heights As per drawings and
design supplied by architect and instruction given by authority and E.I.C.
Chapter 14 Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm
153 14015BA 128.00 nominal size) laid in one layer and finished with a floating coat of neat cement. Sqm 348.08 3.48 351.56
Page - 128 (B) 50mm thick.
Providing and fixing sandwich type granite counter platform, comprising base layer of 25 mm thick polished Kota
stone slab, properly bedded, levelled and supported over intermediate masonry / RCC supports in cement mortar,
and supplying and fixing 18 mm thick first quality “Telephone Black” granite slabs, machine cut, mirror polished, full
round moulded at exposed edges, uniform in colour and texture, free from cracks, laminations and visible defects,
fixed on top surface, side facia and vertical front strip as shown in drawings, bonded using cement mortar and high
performance stone adhesive to ensure full contact and structural stability, including proper alignment, line and level,
edge finishing, cutting and shaping for sink openings of any size, provision for plumbing fixtures, polishing of cut
edges, filling all joints with approved colour matched epoxy grout, finishing smooth, curing, protection and final
cleaning complete, including all labour, materials, scaffolding, T&P, lead and lift, wastage and incidentals, complete
in all respects as per approved drawings, specifications and directions of Authority / Engineer-in-Charge.
Providing and laying 18 mm thick “Telephone Black” or as per selection by architect granite slabs, machine cut, one
side mirror polished, uniform in colour and texture, free from cracks, veins and surface defects, in flooring, laid over
20 mm average thick cement mortar bed (1:6) (1 cement : 6 coarse sand) or levelling mortar 1:1.5 as specified,
including preparation, cleaning and wetting of base, cement slurry bonding coat, proper bedding, alignment,
levelling and compaction complete, joints filled with grey cement slurry and finished flush, including machine
rubbing and final polishing to achieve smooth and even surface, forming edge moulding as per approved
architectural pattern, including making two decorative grooves as detailed in drawings, cutting and fitting around
columns, frames and fixtures, curing, protection and final cleaning without acid damage, including all labour,
materials, T&P, lead and lift, wastage and incidentals, complete in all respects as per approved drawings,
specifications and directions of Authority / Engineer-in-Charge.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing 18 mm thick “Approved Shade” granite slabs, machine cut, mirror polished, uniform in size,
colour and shade, of approved make, free from cracks, veins and surface defects, in skirting, risers of steps, dado, wall
cladding, sills, jambs of doors, windows and ventilator frames, fixed over properly prepared surface using high
performance stone adhesive, including application of minimum two coats of approved construction chemical
bonding agent as per manufacturer’s specification, ensuring proper line, level, plumb and alignment, edge rounding /
chamfering as per architectural detail, cutting and fitting at corners and junctions, filling all joints with approved
colour matched cement putty, finishing with sharp flush joints, final rubbing and polishing, cleaning of surface with
approved mild solution (no acid damage permitted), curing and protection, including all labour, materials,
scaffolding, T&P, lead and lift, wastage and incidentals, complete in all respects as per approved drawings,
specifications and directions of Authority / Engineer-in-Charge.
Providing and fixing 25 mm thick machine cut, free edge, double polished Kota stone slabs for shelves, in single
piece of maximum 1.50 m length, uniform in colour and texture, free from cracks, laminations and surface defects,
fixed in cupboards and wall recesses, including cutting grooves in masonry / RCC walls to required depth,
157 R.A-65 142.00 embedding slab ends in cement mortar, bedding with neat cement slurry to ensure proper bond, maintaining true Sqm 870.81 8.71 879.52
line, level and alignment, edge dressing and polishing of exposed edges, finishing smooth and even, curing and
protection, including all labour, materials, T&P, lead and lift, wastage and incidentals, complete in all respects as per
approved drawings, specifications and directions of Authority / Engineer-in-Charge.
Chapter 14 Providing & laying rough chiseled dressed stone flooring over 20 mm.(average) thick base of cement mortar 1:5(1
158 14014AA 32.00 cement : 5 coarse sand) or L.M. 1:1.5 including pointing with cement mortar 1:2 (1 cement:2 stone dust) etc. Sqm 544.03 5.44 549.47
Page - 128 complete. [A] 25 mm. thick.
Providing and laying approximately 16 mm thick exterior grade heavy duty pavement tiles 300x300mm or higher size
as selected by architect, uniform in colour and texture, of approved make and pattern, suitable for exterior pedestrian
use, laid over 20–25 mm thick cement mortar bed (1:3) (1 cement : 3 coarse sand), bedding thickness varying as per
site levels and slopes, over properly prepared and compacted base, including cleaning and wetting of surface, laying
tiles in true line, level and required pattern as per architectural drawings, bonding with grey cement slurry,
159 R.A-66 128.00 maintaining 4–5 mm wide joints using spacers, or providing specified open joints / pebble stone filled gross joints as Sqm 915.63 9.16 924.79
per approved architectural scheme, no extra payment for forming such joints, pointing joints with approved ready-
made polymer joint sealer, finishing with ruled and sunk pointing, maintaining proper surface alignment and
drainage slope, cutting and fitting at edges, corners and around fixtures, curing, protection and final cleaning,
including all labour, materials, T&P, lead and lift, wastage and incidentals, complete in all respects as per approved
drawings, specifications and directions of Authority / Engineer-in-Charge.
Providing & laying china mosaic flooring of approvd make for plain and curved surfaces at floor, dado, otta etc.
comprising of 20 to 25 mm size broken pieces of ceramic/ glazed tiles (only white colour) laid over 1:6 cement mortar
bedding including applying cement slurry at the rate of 2.75 kg per Sq.m. on plain or sloped surfaces and filling joints
with white cement. The flooring/ dado shall be tampered with wooden rammer not exceeding 2 Kg in weight to bring
the mortar up to the surface including rounding of the junctions and extending them upto 15 cm along the parapet
wall. The rate shall include any type of bands, vata, any colour, any pattern or design as per drawing, curing, cleaning
with water and oxalic acid etc. complete as sample approved by Architect/ EIC. (Only plan area shall be measured
including vata upto 150mm height). Rates should be inclusive of acid washing and vata.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing & laying average 18-20mm thick double coat water proof smooth/ wired finish cement plaster (For terrace)
, 12 to 15mm thick first coat in CM 1:3 (1 cement : 3 coarse sand) by spraying, second coat of 6mm of CM 1:3 (1
cement : 3 fine sand) and mixing non shrinkage compensating waterproofing admixture (Add 330 grams of one
pouch with 1 bag of 50 kg of cement Bag-As per manufracurers specifications) in both coats including finishing with
a flooting coat of neat cement slurry etc complete for all floor. and shall be guaranteed for minimum period of
161 R.A-67 3,156.00 years after handing over the completed building by the main contractor to be finished as directed. Stamp paper Sqm 366.33 3.66 369.99
guarantee 10 years to be furnished before receiving any payment from the client. Waterproofing powder & liquid of
approved make recommended proportions is to be applied before each coat and final finishing coat. (Item shall be
operated for water retaining structures, sunks, basement walls and other places specified As per drawings and design
supplied by architect and instruction given by authority and E.I.C. (For Terrace PU Waterproofing protective layer).
approved make: sunanda/ fosroc/ BASF/ pidilite
Providing and applying hydrophilic crystalline based waterproofing system In two coat application. The application
to be done from +ve(positive) side on a wet open pore green concrete surface at coverage of 0.8to1kg/sqm as per
manufacturer specification. It should be hydrophilic in nature,should be able to grow crystals year after year to seal
microcracks. The product should confirm to DIN1048 part5 and should provide in depth crystallization.The material
and application warranty to be given by manufacturer’s authorized distributor/applicator on prescribed format for10
years.Note:- Treated area should be screeded using hydrophilic crystalline admixture KIM(Krstol Internal Membrane)
162 R.A-68 998.00 @ 2% for be stresults:-Application of crystalline coating to be done within 7days of casting of concrete All the Sqm 495.87 4.96 500.83
waterproofing activities shall be carried out by in-house application company of the principal material manufacturer
and provide a written corporate Supply Apply Corporate Warranty from the principal manufacturer that all work
executed will be free from defects in materials, workmanship and free of leaks for a period of 10 years from the date
of Work Completion, unless resulting from structural defects or causes other than the work of this section. Said
defects shall be remedied by the principal manufacturer for the period of the warranty without additional cost to the
owner for waterproofing material only. (For Sunken area waterprrofing)
Providing and laying 115mm over deck insulation over terrace water proofing of ex-foliated vermiculite of MFV/
Porosile / Vermiplast or equivalent as per approved make for roof insulation in the ratio of 1 :6 (1 cement : 6 Ex
foliated vermiculite (by volume)). Density of Ex foliated vermiculite shall be 212 kg/cum. The cement shall be mixed
with the ex foliated vermiculate in dry stage & then minimum qty of water shall be added. After screeding the ready
mixed material in specified thickness, curing shall be carried out at least for 7 days by sprinkling of required quantity
of water so that surface remains damp and not to be done by ponding or flooding. The work includes cleaning of the
surface with wire brush thoroughly necessary scaffolding finishing the top surface as best workmanship like
manner as per the manufacturers specifications.All the waterproofing activities shall be carried out by in-house
application company of the principal material manufacturer and provide a written corporate Supply Apply Corporate
Warranty from the principal manufacturer that all work executed will be free from defects in materials, workmanship
and free of leaks for a period of 10 years from the date of Work Completion, unless resulting from structural defects
or causes other than the work of this section. Said defects shall be remedied by the principal manufacturer for the
period of the warranty without additional cost to the owner for waterproofing material only.etc complete As per
drawings and design supplied by architect and instruction given by authority and E.I.C.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying PU- Liquid Applied polyurethane membrane terrace waterproofing system, Clean the RCC
surface of all loose particles, dust, cement laitance etc. preferably done using floor polishing machine or any other
mechanical tools. Surface preparation is of prime importance as the degree of performance of the coating is directly
proportional to the extent of cleaning Identify the cracks, construction joints, honeycombed areas etc. on the RCC
surface. Injection grouting shall be done at construction joints with providing and injection non shrink cementations
grout by mixing – 2 pouches (330 gms. Each) and 50 kgs of cement and sufficient water for flow ability, Grouting the
same under pressure in pre-drilled holes by grouting pump etc. After grouting is completed after 24 hours, cut the
nipples and seal it with PMM.Prepare a coving at the construction joints upto 250 mm on either side of the joints
using PU- Liquid Applied polyurethane membrane with min elongation of > 600 % (ASTM D412) with pH 8.5-10 and
90%+/- 3% and conforming to DIN 1048 for zero permeability at 7 bars of water pressure. Apply PU PRIMER at the
junction and allow it to dry for min 30-40 min. After primer has cured apply 1st coat of PU by brush. Cut a strip of
geotextile and tightly placing it along the junction. Apply second coat of PU over the geotextile in such a way that
no air bubbles are left in between. Fill all the cracks using PU- Liquid Applied polyurethane membrane. Slightly
widen the crack using a cutting device and clean the same using air blower to remove dust particles. Apply PU
PRIMER in the crack and then after 1 hr inject PU into the crack. After 3-4 hrs check for any absorbency if any fill the
crack again till it gets filled. Providing and applying single component liquid applied polyurethane based
waterproofing membrane of PU to the entire area at the dose of 1.5 kgs per m2 Apply single coat of PRIMER with the
help of brush and allow it to dry for 2-3 hours. After primer has dried apply TWO coats of PU a single component
moisture cured,polyurethane based elastomeric membrane. Apply First coat of PU at 1 kg per m2 rate and allow it to
cure for 24-48 hrs. Apply second coat PU at 0.5 kg per m2 rate. To provide key for the screed, sand should be
broadcasted while the second coat is still tacky. etc. complate As per drawings and design supplied by architect and
instruction given by authority and E.I.C. approved make: sunanda/ fosroc/ BASF/ pidilite
Providing and fixing 16 mm thick multiwall polycarbonate roofing sheets (Lexan / Bayer or equivalent approved
make), UV resistant, light transmission grade as specified, fixed over structural steel / aluminium framework,
including supply and installation with approved self-drilling Hilti screws with EPDM washers, providing 50 mm ×
mm aluminium strips at joints and supports, application of approved silicone weather sealant to ensure watertight
sealing, proper alignment, edge finishing, provision for thermal expansion gap as per manufacturer’s specification,
cutting to required size, fixing ridge / side closures where required, protection film removal after installation,
complete including all labour, materials, scaffolding, T&P, lead and lift, wastage and incidentals, complete in all
respects as per approved drawings, manufacturer’s specifications and directions of Authority / Engineer-in-Charge.
Providing and fixing structural steel work welded in built-up sections and hollow sections, including columns, beams,
joists, channels, M.S. flats, angles, pipes, tees, plates and cleats, fabricated as per approved structural drawings,
including cutting, bending, welding, drilling, grinding, assembling, hoisting and fixing in position true to line and
level, complete with all necessary connecting plates, angle cleats, gusset plates, bolts and welds, including surface
preparation by wire brushing / cleaning to remove rust, scales and oil, applying one coat of approved zinc rich / red
oxide primer and two coats of synthetic enamel / oil paint of approved shade, including all labour, materials, T&P,
scaffolding, lead and lift, wastage and incidentals, complete in all respects as per approved drawings, specifications
and directions of Authority / Engineer-in-Charge.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing 600mm × 600mm or approved size aluminium metal tile ceiling system, comprising 0.7 mm
thick aluminium clip-in plain tiles with antimicrobial coating, factory finished, uniform in thickness and shade, with
tile ends raised with pips and stops to ensure positive engagement into spring system for secure locking and easy de-
mounting of individual panels, tile sides sufficiently stiffened to ensure minimum deflection across length, edges
either bevelled or square as approved, powder coated with IAM series polyester based powder coating formulated
without TGIC, coating tested by independent laboratories conforming to internationally recognised standard JIS Z
2801:2000 for antimicrobial performance, tiles clipped into 0.5 mm thick G.I. clip-in rails, grid suspended from RCC
slab using 4 mm diameter G.I. suspension rods, hold-on clamps with clips and necessary accessories, including
alignment, levelling, perimeter trim, edge profiles, cutting for light fixtures, diffusers and services, providing
expansion provisions as per manufacturer’s specification, complete with all labour, materials, T&P, scaffolding, lead
and lift, wastage and incidentals, finished true to line and level, complete in all respects as per approved drawings,
manufacturer’s specifications and directions of Authority / Engineer-in-Charge.
Make: Oculus® Building Products Pvt. Ltd. / Hunter Douglas India Pvt. Ltd. / Lindner Middle East or equivalent
Providing and fixing gypsum board false ceiling system in approved design, comprising G.I. perimeter channel of
mm thickness having one flange of 20 mm, another flange of 30 mm and web of 27 mm fixed along the perimeter of
ceiling to brick work / concrete / partition using nylon sleeves and screws at 610 mm centre to centre, suspending
G.I. intermediate channels of 45 mm width, 0.9 mm thick, having two flanges of 15 mm each, from soffit at 1220 mm
centre to centre using ceiling angles of size 25 mm × 10 mm × 0.5 mm thick fixed to soffit with G.I. cleats and steel
expansion fasteners, fixing ceiling sections of 0.55 mm thickness having knurled web of 51.5 mm and two flanges of
26 mm each with 10.5 mm lips, connected perpendicular to intermediate channels at 450 mm centre to centre using
connecting clips, fixing 12.5 mm thick tapered edge gypsum boards conforming to IS 2095 (Part I) to ceiling sections
with 25 mm long drywall screws at 230 mm centre to centre using mechanical drilling machine, finishing joints and
tapered edges with jointing compound, paper tape and finishing compound to achieve smooth flush surface,
including forming drops, offsets, curves, mouldings, geometric patterns, providing cut-outs for light fixtures,
speakers, sprinklers, smoke detectors, trap doors, A.C. grills and diffusers, providing additional framing support
around ducts and service openings wherever required, marking grid lines, complete surface preparation including
application of plaster putty, two coats of primer and minimum three coats of plastic emulsion paint of approved
shade, including scaffolding, labour, materials, T&P, lead and lift, wastage and incidentals, complete in all respects as
per approved drawings, specifications and directions of Authority / Engineer-in-Charge.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15mm Thick
Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have, light
reflection 85% non-combustible as per B.S. 476 part IV & also Non - Combustible / Zero Smoke Emmission as per UL -
723, 100% humidity resistance and also having thermal conductivity 0.043° w/m KC. & also having Anti - Microbial
Protection as Per JIS - Z2801 - 2010 for the best thermal Insulation. The Light weight calcium Silicate tile shall be of
approved texture Fine fissured/ Spintone/Cosmos/Spectra having NRC value of 0.5 & Globe having NRC value of
NRC or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking metal grid of hot
dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main 'T' runner
suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet,
1200mm centre to centre, and cross 'T' of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm
along spaced between main T' at 600mm centre to centre to form a grid of 1200X600mm and secondary cross "T' of
length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be interlocked at middle of the
1200X600mm panel to form grid of size 600X600mm resting on periphery walls/partitions on a perimeter wall angle
pre-coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at
450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges
light weight calcium silicate ceiling tiles of approved texture (Fine Fissured/Cosmos/Spintone/Spectra) in the grid
including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.,
wherever required, Main Trunners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed
to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips
of size 85X30X0.8mm, spaced at 1200mm centre to centre long main "T" bottom exposed with 24mm of all T-
sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as
directed by engineer- in-charge.Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No
deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate
ceiling tiles shall have NRC. Value of 0.50 (Minimum) for Fine fissured/Spintone/Cosmos and 0.75 NRC for Globe,
Providing plinth protection to building including excavation in ordinary soil to required depth and width, dressing
and levelling the bed, laying 100 mm thick cement concrete (1:5:10) (1 cement : 5 coarse sand : 10 graded stone
aggregate 20 mm nominal size) as foundation layer, constructing brick masonry in cement mortar (1:6) to required
height where specified, and providing 100 mm thick cement concrete (1:2:4) (1 cement : 2 coarse sand : 4 graded
170 R.A-75 218.00 stone aggregate 20 mm nominal size) as top coping, finished with 10 mm thick cement plaster, broom finish on top Sqm 1,340.84 13.41 1,354.25
surface, forming square line markings of 0.20 m × 0.20 m on top and sides as detailed, including proper slope away
from building for drainage, curing, finishing, cleaning, including all labour, materials, T&P, lead and lift, wastage and
incidentals, complete in all respects as per approved drawings, specifications and directions of Authority / Engineer-
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing 250 mm expansion joint system of Horizontal Internal : Floor to Floor FF , Floor to wall, Roof to
wall: The work shall consist supply and installation of joints and seals -expansion/seismic joint system 3R/Kantaflex
model MSDSZJ/ MSD -QSZJ / MSDGCP/ MSWG/ MSW-QG/ MSDGCP/ MSD-QGCP in accordance with the drawings
and requireements of the specifications below. The joints are proprietary design utilizing extruded aluminum base
members ,self aligning / centering arrangement and support plates.The material shall be such that it provides
wateright flat joint cover expansion control sysytem that is capable of accommodating multidirectional seismic
movement without stress to its components.System shall consisit of metal profile that incorporates a universal
aluminum base member designed to accommodate various project conditions and floor/roof treatments. including
cover plate, The cover plate shall be designed of width and thickness requried to satisfy projects movement and
loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-centering
arrangement that freely rotates / moves in all directions. The self - centering arrangement shall exhibit circular sphere
ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and
flexure in all directions including vertical displacement ,Including EPDM Profile including cost of GP2 grouting. The
joint sysytem shall resist damage or deterioration from the impact of falling ice, exposure to UV,airborne
contaminants as per manufacturer speciation and the joint design and drawing ,etc., complete all As per drawings
and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing 250 mm expansion joint system for Vertical joints :3R/Kantaflex of MSNG/ MSNSK/ MSN-QSK/
MSN-QG system designed for internal/External wall and ceiling finishes with expansion movement of design for
internal/EXTERNAL application on wall to wall/ceiling /wall to corner including exposed metal plate /consealed metal
plate /flush metal plate desired as per the joint design and design width over the joint profile INCLUDING EPDM
Profile including GP2 grouting as per the joint manufacturer speciation and the joint design and drawing ,complete
all As per drawings and design supplied by architect and instruction given by authority and E.I.C. (Vertical)
Providing and Fixing Rubber Corner Guard -800 x 100 x 100 MM x 6 MM BLACK WITH YELLOW REFLECTIVE
173 R.A-78 168.00 SHEETING FIXED ON THE WALL WITH SIX 2” SCREWS etc. complete As per drawings and design supplied by Nos. 379.50 3.80 383.30
architect and instruction given by authority and E.I.C.
Providing and fixing ABS plastic modular speed bump units of size 750 mm × 250 mm × 75 mm, heavy duty, impact
resistant, with anti-skid line pattern top surface for enhanced tyre grip, in black and yellow combination, 4 Nos. per
running metre (2 black + 2 yellow), filled internally with cement concrete for added strength and stability, fixed firmly
to finished road surface using suitable anchor bolts with sleeves, including drilling, alignment, proper spacing,
tightening, finishing, cleaning and all labour, materials, T&P, lead and lift, wastage and incidentals, complete in all
respects as per approved drawings, specifications and directions of Authority / Engineer-in-Charge.
SIGNAGES HANGING FROM CEILING - Providing, Fabricating & Fixing signage's using 304 grade Stainless steel
mm thick brushed steel finish plate (2 nos) with 8mm thk. Acrylic sheet covered with vinyl of approved colour,
sandwiched between two S.S plate and fixed with s.s struds . Sandwiched plates should be fixed in 12mm X 12mm
175 R.A-80 39375.00 S.S 1.5mm thk.304 grade frame and punched (laser cut) lettering carried out on both the s.s plates of required size Sq.inch 68.30 0.68 68.98
and text as directed by Engineer and hanged to ceiling with the help of S.S 8mm thick chain at both ends with
making all the fixing arrangement to the ceiling and to the plate etc. complete all As per drawings and design
supplied by architect and instruction given by authority and E.I.C.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Supply & installation of Manual Roller blinds having Alluminium Roller tube along with fabric pasted on it with glue
having control unit for manual operations and bottom bar Aluminum powder coated for weight purpose, including
fabric, fitting & accessories complete as directed by EIC. Fabric to be approved by architect. etc. complete As per
drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing of Verticle Blinds fixed at all levels and sizes as per the manufacturers specifications . Fabric to
177 R.A-82 76.00 be approved by architect. Make : Vista or equivalent etc. complete All As per drawings and design supplied by Sqm 1,225.00 12.25 1,237.25
architect and instruction given by authority and E.I.C.
Supplying and Installing of Metalium SL-4 type 84R Aluminium 0.65mm TCT Plain Exterior Grade Powder Coating of
178 R.A-83 735.00 Panels and Back side Framming G.S. Black Exterior Louvre System. etc. complete All As per drawings and design Sqm 2,359.01 23.59 2,382.60
supplied by architect and instruction given by authority and E.I.C.
Supply & Installation external cladding using fibre cement plank of cassia/ straight grain/ teak coloured texture
(External Grade) thickness 8mm and dimension 150mmX3000mm. Fibre cement plank should be of minimum density
1300kg/ m3 (±50) and comply to ASTM C 1185 and ISO 8336 part (E) for confirming durability properties and BS
– part 5, 6 & 7, Thermal conductivity should be minimum 0.15 W/m˚K and PH value should be in the range of 7 –
Depending on height of structure Board to be fixed using Aluminium rectangular frame section of suitable gauge
with minimum spacing 450mm to 600mm or As per drawings and design supplied by architect and instruction given
by authority and E.I.C., Plank to be fixed using Screws of Tensile strength 34N and Shear strength 68N on framing
maintaining distance of minimum 25mm between two planks . All plank to plank joints to be staggered and finished.
Providing & laying Tac tile 300mm x 300mmx 15mm flooring. The tile laid using with adhesive as per site condition
180 R.A-85 675.00 including all labour and material, cleaning, curing, etc., complete all As per drawings and design supplied by architect Sqm 2,552.25 25.52 2,577.77
and instruction given by authority and E.I.C.
Providing & Laying polypropylene Flutted corrugated Floor Protector Sheets used for Floor Protection of Vitrified Tile
etc. Complete. without damage of tiles including neat and clean of flooring & including loading, lifting,transporting,
and disposal of debries outside of plot boundry et. complete with all leads & lift. etc completed As per drawings and
design supplied by architect and instruction given by authority and E.I.C.
Providing & applying single part non shrink cementitious crack sealer for wider surface crack filler on existing
concrete/ plaster surface. The cracks to be sealed shall be saw cut or chiselled to/form a V groove at approx. of
6mm x 6mm, The grooves shall be cleaned to remove all the loose particles, dust etc. The groove shall be sprinkled
with clean water before applying sealing mortar- cementitious crack fillar shall be mixed with water adopting w/c
ratio and a mix proportion of 1 part of water to 3.0 part of filler mixer by volume or as per manufacturer's
specifications. Thorough mixing shall be carried out till a smooth, homogeneous paste is obtained. The mixed paste
is fiiied into groove by gloved hand and the surface finished using a trowel. This continued till the full length of crack
is sealed proper curing shall be done if groove size exceed 6mm width or required otherwise as per site condition.
The entire applications shall be done As per drawings and design supplied by architect and instruction given by
authority and E.I.C. (For payment purpose actual quantity of Non-shrink cementitious grout shall be accounted)
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and applying Bonding agent of bind old and new concrete after removing the cover of the old
concrete and cleaning the surface thoroughly. Application of the bonding agent shall be done as per manufacturer's
specification and instructions and as directed. Rates to be inclusive of scaffolding, staging etc. complete.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing & Fixing anchor fasteners including drilling in RCC / Masonary Members, fastening with structural steel
members etc complete all As per drawings and design supplied by architect and instruction given by authority and
Providing & Fixing anchor fasteners including drilling in RCC / Masonary Members, fastening with structural steel
members etc complete all As per drawings and design supplied by architect and instruction given by authority and
Providing & Fixing anchor fasteners . including drilling in RCC / Masonary Members, fastening with structural steel
members etc complete all As per drawings and design supplied by architect and instruction given by authority and
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after
drilling the hole of required diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar
inserting reinforcement bar etc. complete as per Manufacturers & architects instruction.The work shall be carried out
187 R.A-90 560.00 by the technical workmens/agency approved by the manufacturer and under technical supervision of Manufacturer Each 120.87 1.21 122.08
of Injection grout including all materials,tool tackles ,labour etc.complete all As per drawings and design supplied by
architect and instruction given by authority and E.I.C.
(a) 8 mm. dia.bar -Holes 12mm dia Depth 100mm
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after
drilling the hole of required diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar
(HY 150 or approved equivalant),inserting reinforcement bar etc. complete as per Manufacturers & architects
188 R.A-90 560.00 instruction.The work shall be carried out by the technical workmens/agency approved by the manufacturer and Each 157.72 1.58 159.30
under technical supervision of Manufacturer of Injection grout including all materials,tool tackles, labour
etc.complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
(B) 10 mm. dia.bar -Holes 14mm dia Depth 100mm
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after
drilling the hole of required diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar
(HY 150 or approved equivalant),inserting reinforcement bar etc. complete as per Manufacturers & architects
189 R.A-90 560.00 instruction.The work shall be carried out by the technical workmens/agency approved by the manufacturer and Each 195.73 1.96 197.69
under technical supervision of Manufacturer of Injection grout including all materials,tool tackles, labour
etc.complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
(C) 12 mm. dia.bar -Holes 16mm dia Depth 120mm
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after
drilling the hole of required diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar
(HY 150 or approved equivalant),inserting reinforcement bar etc. complete as per Manufacturers & architects
190 R.A-90 250.00 instruction.The work shall be carried out by the technical workmens/agency approved by the manufacturer and Each 250.88 2.51 253.39
under technical supervision of Manufacturer of Injection grout including all materials,tool tackles, labour
etc.complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
(D) 16 mm. dia.bar -Holes 20mm dia Depth 160mm
Providing & fixing of reinforcement bars ( reiforcement bars shall be paid extra under relevant item of work ) after
drilling the hole of required diameter & depth ,cleanning of the same ,providing /filling the hole with Injection Mortar
(HY 150 or approved equivalant),inserting reinforcement bar etc. complete as per Manufacturers & architects
191 R.A-90 250.00 instruction.The work shall be carried out by the technical workmens/agency approved by the manufacturer and Each 455.40 4.55 459.95
under technical supervision of Manufacturer of Injection grout including all materials,tool tackles, labour
etc.complete As per drawings and design supplied by architect and instruction given by authority and E.I.C.
(E) 20 mm. dia.bar -Holes 24mm dia Depth 200mm
192 R.A-91 200.00 Making holes upto 16mm dia. in masonry by hammer drilling machine including disposing the debries. Nos. 98.53 0.99 99.52
193 R.A-91 200.00 Making holes upto 22mm dia. in masonry by hammer drilling machine including disposing the debries. Nos. 99.71 1.00 100.71
194 R.A-91 200.00 Making holes upto 28mm dia. in masonry by hammer drilling machine including disposing the debries. Nos. 112.61 1.13 113.74
195 R.A-91 200.00 Making holes upto 40mm dia. in masonry by hammer drilling machine including disposing the debries. Nos. 153.66 1.54 155.20
Making holes upto 52mm dia. in any RCC members by diamond Core Cutting machine including disposing the
Making holes upto 75mm dia. in any RCC members by diamond Core Cutting machine including disposing the
Making holes upto 102mm dia. in any RCC members by diamond Core Cutting machine including disposing the
Making holes upto 125mm dia. in any RCC members by diamond Core Cutting machine including disposing the
Making holes upto 152mm dia. in any RCC members by diamond Core Cutting machine including disposing the
Making holes upto 200mm dia. in any RCC members by diamond Core Cutting machine including disposing the
Making holes upto 250mm dia. in any RCC members by diamond Core Cutting machine including disposing the
Making holes upto 300mm dia. in any RCC members by diamond Core Cutting machine including disposing the
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Avg 100 mm thick cement concrete flooring with concrete hardener topping, under layer 70 mm thick cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick
cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by
volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This
includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete all As per drawings and design
supplied by architect and instruction given by authority and E.I.C.
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through
Chapter 11 their entire length and jointed together at the ends by end locks mounted on specially designed pipe shaft with
205 11005B 84.00 bracket plates, guide channels and arragements for inside and outside locking with push-pull operation including the Sqm 4,450.51 44.51 4,495.02
Page - 111 cost of hood cover and spring etc. complete.
(B) Shutters having width 3.5 M. and above
Carring out plinth treatment to post construction / existing structure by spraying chemical solution for termite
control treatment including labour and material consistment with I.S.I specification. Using Chlordene and
Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration Weight one percent is recommended i.e one litre 20 EC
chemical emulsion with 19 liter give 1 % concrentration inclusive of one litre chemical emulsion appication at the rate
of 5 Litre chemical / Sqm of surface is recommended as per I.S. or As per drawings and design supplied by architect
and instruction given by authority and E.I.C.
Providing and fixing pre-cast Rubber Dye inter locking concrete block 60mm thick with grade of concrete M300
pnumatic compressed by mechanically pressed and as per approved design including 75 mm sand layer for levelling
and filling the joint with sand in proper line and level etc. completed all As per drawings and design supplied by
architect and instruction given by authority and E.I.C.
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and
15cm thick of M250 grade concret as per approved design and including excavation for fixing in proper line and
level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete all As per drawings and design supplied by
architect and instruction given by authority and E.I.C.
Providing and Laying Grassing with selection No.1 grass In rows 5 cm apart in both directions including watering and
maintenance of the lawn for 12 months or more till the grass forms a thick lawn, free from weeds and fit for mowing
including supplying farm clay up 300 mm thick, sludge, manure,pesticides , extra earth, disposal of rubbish, trench
excavation and all labour with lead and lift etc. complete
Providing & construction Tree plants required Digging of pits 0.6mt. x 0.6mt x 0.6mt, filling with goodearth with
mixing of cow dong and pesticide.planting the following plant of 4' to 6' height stack it well, maintain it for 3 month
210 R.A-94 105.00 name of plants Neem, Nagor, Avonla, Aritha, Garmala, Neem, Nagor, Avonla, Aritha, Garmala, Neem, Nagor, Nos. 293.00 2.93 295.93
Avonla, Aritha, Garmala, etc all As per drawings and design supplied by architect and instruction given by authority
Ayurvedic shrubbery Clinning the bed, mixing of the fertilizer and pesticides, digging the pit planting the good
quality of plant at required distance, maintain it for 12 month name of plants Tulsi, Brahmi, Aloe vera, Ardusi,
Asparagus, Panputti, Nagar vel, Phudina, Ashwagandha, Gugal, Wedellia, Jecomentia, Umbrella palm, etc
Note:- As per drawings and design supplied by architect and instruction given by authority and E.I.C.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Planting of exoitic palm trees Digging of pits 0.6mt. x 0.6mt x 0.6mt, filling with good earth with mixing of cow dong
and pesticide.planting the following plant of 8' to 10' height stack it well, maintain it for 12 month Bottle palm,
Coconut, Sopari, Fish tail, Fox tail, Phonix, Date palm, Bismarkia, Shampagon, Latania, etc
Note:- As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Planting of Ornamental shurbs Digging of pits 0.6mt. x 0.6mt x 0.6mt, filling with good earth with mixing of cow
dong and pesticide.planting the following plant of 8' to 10' height stack it well, maintain it for 12 month Golden
213 R.A-97 27.00 bamboo, Green bamboo, Ficus spp.Ixora spp., Hibiscus spp., Allamanda spp.Bougainvella spp., Nerium spp, Plumeria Nos. 173.00 1.73 174.73
Note:- As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing pesticides ,dust As per drawings and design supplied by architect and instruction given by authority and
Providing pesticides ,liquid As per drawings and design supplied by architect and instruction given by authority and
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m hight, above ground consisting 4 nos 25 x 6 mm,
2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6mm M.S. flat iron rings in two
halves, fixing together at site withrequired six numbers of 8 mm dia. and 30 mm long bolts, including painting two
coats with synthetic enamel paint of approved brandand manufacture over a coat of primer. One name plate of
mmthick M.S. sheet of size 250x100 mm shall be welded to the treeguard near the middle height and lettered PIU/
any other approved name. The tree guard shall be suitably fixed to the groundby embedding four legs of tree guard
in pits of suitable dia and to adepth of 25 cm, refilling the pits with soil and ramming, complete inall respect As per
drawings and design supplied by architect and instruction given by authority and E.I.C.
Hording Erection of approved size (20' x 10') including 2" MS square pipe/ gurder ,1.5" pipe framing G.I sheet 26 or
217 R.A-101 2.00 28 gauge, Flex. as per the Architect's instructions & approval. Each 42,550.00 425.50 42,975.50
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing bright finish 2 mm thick Stainless steel (Grade 304) 3D letters box size up to 900 cm height in
English language with Acrylic cut work and fixing 3mm acrylic on top of brand Ptglass,astari etc,with all laser and cnc
218 R.A-102 315.00 work,including LED lighting illumination, all material, labour and other hardwares, waste of materials etc fixed in wall Each 633.00 6.33 639.33
at any height including scaffolding etc complete As per drawings and design supplied by architect and instruction
given by authority and E.I.C.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints
between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete
all As per drawings and design supplied by architect and instruction given by authority and E.I.C.) Serrated with
central bulb (225 mm wide, 8-11 mm thick)
Providing & fixing CP brass double coat hook of premium quality etc. complete. As per drawings and design supplied
by architect and instruction given by authority and E.I.C.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Constructing RCC Under Ground water tank with Providing and laying controlled cement concrete M300 mix for
R.C.C. work including reinforcement, boxing, centering, vibrating, , PVC water stopper, curing and mixed with
approved water proofing cement compound or "CEMWET" or "PIDICRETE LW" integral water proofing admixture as
water proofing agent to be mixed with 50 kgs. bags shall be as recommended by the manufacture of the water
proofing material, concrete work for top, bottom slab & side pardi for underground water tank item incl. Necessary
221 R.A-105 388,500.00 excavation & refilling the available earth, 150 mm thick 1:2:4 for bedding of concrete, 20 mm thk. water proofing Liter 17.00 0.17 17.17
cement plaster in C.M. 1:3 with smooth finishing, Glazed Tile Flooring & Glazes Tile Dado in 1:3 (1 cement : 3 coarse
sand) & 10 mm thick, vata, watering etc. Comp. to all face of tank including locking arrangement outlet, inlet,
overflow and washout outlet pipe arrangement as necessary & C.I. Cover 0.60 x 0.45 weight not less then 35 kg with
locking arrangement. etc. comp as per structural drawing Including Reinforcement TMT-FE500D As per drawings and
design supplied by architect and instruction given by authority and E.I.C.
Constructing RCC Overhead water tank with Providing and laying controlled cement concrete M300 mix for R.C.C.
work including reinforcement, boxing, centering, vibrating, , PVC water stopper, curing and mixed with approved
water proofing cement compound or "CEMWET" or "PIDICRETE LW" integral water proofing admixture as water
proofing agent to be mixed with 50 kgs. bags shall be as recommended by the manufacture of the water proofing
material, concrete work for top, bottom slab & side pardi for Overhead water tank item incl. 20 mm thk. water
proofing cement plaster in C.M. 1:3 with smooth finishing & Glazes tile Dedo, vata, watering etc. Comp. to all face of
tank . including locking arrangement outlet, inlet, overflow and washout outlet pipe arrangement as necessary & C.I.
Cover 0.60 x 0.45 weight not less then 35 kg with locking arrangement. etc. comp as per structural drawing Including
Reinforcement TMT-FE500D As per drawings and design supplied by architect and instruction given by authority and
Providing and fixing High Pressure Laminate (HPL) compact grade cladding system including complete supporting
framework, conforming to IS 2046 and EN 438, manufactured under high pressure exceeding 5 MPa and temperature
above 120°C, comprising layers of kraft paper impregnated with thermosetting phenolic resin and decorative paper
impregnated with thermosetting melamine resin, UV resistant, weather resistant, moisture resistant, anti-graffiti and
anti-bacterial, of approved shade, texture and minimum 6 mm thickness or as specified, fixed over complete
aluminium / hot dip galvanized steel sub-framing system comprising vertical and horizontal members, brackets,
cleats, anchor fasteners, spacer blocks and necessary accessories, mechanically anchored to RCC / masonry substrate
with stainless steel fasteners, providing required cavity gap for ventilation, maintaining expansion joints as per
manufacturer’s specification, cutting, drilling, edge sealing, alignment, plumb and level, sealing joints with approved
weather grade sealant where required, including all hardware, scaffolding, labour, materials, T&P, lead and lift,
wastage and incidentals, complete in all respects as per approved drawings, manufacturer’s specifications and
directions of Architect / Engineer-in-Charge.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and laying of Hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads and
250 gms per Sq.m. area thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC-35 2015. The
finished surface to be level/uniform and free from streaks and holes or chipping of Thermoplastic if any and
including primer coat for C.C. surface and A.C.C. surface, in white and/or yellow colour. Rate includes brushing,
blooming and cleaning and application of paint. Zebra patta/Bump patta/Lane line/Center line/Cut patta, Directional
Arrow, Lettering MoRT&H Clauses 803 &Volume II Part III and IRC 35-2015.Rate shall include brushing, brooming,
painting and repainting of worn out paint after a period of 2.5 years.
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing G.I. chain link fencing of required width in mesh size 50x50 mm including strengthening with
mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I.
wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade Note:-As per
drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing Flush Door both sides laminated shutter fabricated from 35 mm thick solid core malemine faced
three layered pre laminated flat pressed wood based exterior grade bonded BWP/BWR synthetic resin having
stamped IS 12823 grade I type II including three coats of lacquer polishing to exposed wooden surfaces and
including providing and fixing of Floor door stopper & fixing of S.S finish decorative type heavy guage designs
fixtures / fastening etc. complete As per drawings and design supplied by architect and instruction given by authority
Providing erecting and fixing three coated white Syntex/ Astral/ Supreme/RC Plasto PVC. (ISI) water tank of required
227 R.A-111 63,000.00 capacity each with all necessary fittings and connection on terrace. etc. complete as per drawings and design Liter 13.80 0.14 13.94
supplied by architect and instruction given by authority and E.I.C.
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges
sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural
drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of
M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with
cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size
300x230x300 mm, including cost of necessary centring and huttering and with approved expansion hold fasteners on
CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to
228 R.A-112 12,932.00 support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin-charge Kg 143.55 1.44 144.99
and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the
Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical
lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps
shall be paid for separately and nothing extra shall be paid).
Note:-As per drawings and design supplied by architect and instruction given by authority and E.I.C.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with
stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work
at suitable location, including making necessary recesses in stone slab, drilling required holes, etc. complete as per
drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing dry cladding with sand stone 30 mm thick as per selection upto any height with 18 mm thick
gang saw cut stone with (machine cut edges) of uniform colour, fixed to structural steel frame work and / or with the
230 R.A-114 569.12 help of cramps, pins etc. and sealing the joints with approved weather sealant As per drawings and design supplied Sqm 2,875.00 28.75 2,903.75
by architect and instruction given by authority and E.I.C. (The steel frame work, stainless steel cramps and pins etc.
shall be paid for separately.)
Providing and Fixing grc-glass reinforced concrete screen, beam, pillar in approved design, pattern, sizes and colour
to be fixed on existing structure of ms or rcc. the grc should be made from ‘53 grade’ cement , quartz, fine silica
sand, alkali resistant glass fiber , super plasticizers manufactured by ‘basf’ or equivalent, polymers and u.v resistant
synthetic inorganic pigments should be used for pigmentation. the material casting should take place in frp mould or
equivalent. the fixing of grc should be ‘dry fixing’ as per the drawings approved by engineer in charge. etc. complete
as per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and fixing Corten Steel (Weathering Steel conforming to ASTM A588 / equivalent grade) as per
architectural elevation drawing cladding/fins of minimum 3 mm thickness, laser cut and bent to required profile,
fabricated in approved pattern, including MS/GI secondary framing of required section, cleats, base plates, stiffeners,
nuts, bolts, SS fasteners, anchor fasteners, welding, grinding and finishing, fixed to RCC/structural members as per
232 R.A-115 1,096.00 approved structural design and architectural drawings and directions of Engineer-in-Charge, complete. Sqm 5,852.35 58.52 5,910.87
The item includes shop fabrication, transportation, erection, alignment, necessary edge stiffening, provision of
expansion gaps, scaffolding, anti-corrosion treatment (zinc rich primer and synthetic enamel paint) to all concealed
MS members, and all incidental works required for proper installation, Finish: Natural weathered Corten finish (self-
protective oxide layer). Thickness: Minimum 3 mm.
Providing and fixing brass T patti as per required design for installation in wpc cladding or Tiles cladding as directed
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain
approved colour cladding , in approved pattern and design for wall cladding, duct / shaft covering, partitions and
façade applications, manufactured from virgin polymer of K value 58–60 (suspension grade), calcium carbonate and
natural fibres (wood powder / rice husk / wheat husk) with non-toxic additives (maximum toxicity index 12 for
gms), having minimum density 650 kg/cum, minimum screw withdrawal strength 1800 N (face), minimum
234 R.A-117 197.00 compressive strength 50 N/mm², modulus of elasticity 850 N/mm², resistance to spread of flame Class A category, Sqm 3,437.15 34.37 3,471.52
termite proof, borer proof, water and moisture resistant and fire retardant properties, machine cut to required size,
edges finished smooth, fixed over M.S. framework of 25 × 25 × 1.5 mm square hollow section grid at 1.0 m × 1.0 m
or as required at site, including drilling, alignment, levelling, fixing with stainless steel fasteners and SS screws,
cutting and fitting at corners and junctions, complete in all respects as per approved drawings and directions of
Engineer-in-Charge.
ITEM NO. SOR Total Quantity Item of Description Unit Rate 1% L.C Amount
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) >
solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick
235 DSR 12.55 2,662.00 cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & Sqm 1,703.95 17.04 1,720.99
marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including
providing skirting upto 150 mm height along the parapet walls in the same manner.
Total Amount of Civil Work
Total Amount of Civil Work
PROPOSED NEW COMSTRUCTION OF CYCLOTRON AND NUCLEAR MEDICINE BUILDING FOR GCRI AT ASRAWA, AHMEDABAD
BOQ - Plumbing Work
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
A) SANITARY FIXTURES AND FITTINGS
Providing, Installation, testing & commissioning, in position European water
closet comprising of Wall hung European W.C. Pan in white colour, on
approved type of chairs. 15 mm Concealed flush tank as directed.
C.P health faucet with required length of flexible tube, clamp and bracket for
fixing to wall, 15 mm C.P. brass heavy quality angel stop cock for flushing
Fixing W.C. unit with chair brackets and accessories in position.
23010 23.112 European Wall Hung (rate changes possible as per market rate )
23011 23.113 Pan Connector
23013 23.115 Providing and fixing 12.5 Litres low level flushing cistern
23017 23.121 Seat Cover
798 M739 Health Fauset Heavy duty with hook with fitting
777 M718 C.P. Angle stop cock 15 mm Heavy duty with cap
Providing, Installation, testing & commissioning, in position White vitrious
ching W.C. sqatting pan Orrisa type
580 x 400 size in white colour, on approved type of chairs. 15 mm open flush
tank as directed.
C.P health faucet with required length of flexible tube, clamp and bracket for
fixing to wall, 15 mm C.P. brass heavy quality angel stop cock for flushing
23009 23.111 Orissa Pan
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
23012 23.114 Foot rest
778 M719 C.P. Bib cock 15 mm Heavy duty with cap
Providing, Installation, testing & commissioning, Wash basin with tap hole on
basin comprising of Concealed type brackets fixed to wall with adjustable
clamp to push against counter rim. Concealed body parts for basin spout
fixed to wall with basin Spout 32 mm heavy plated C.P. waste coupling fitting
with or without pop-up.
C.P. bottle trap with cleaning eye with extension piece and wall flange.
1.3 Painting brackets with two coats of white enamel paint over one coat of Nos. 74.00 2,473.68 24.74
CP Wash Basin Pillar Cock 15 mm C.P. brass heavy grade flexible inlet
15 mm C.P. brass heavy quality angle stop cocks
23020A 23.135 Waste Coupling
Providing and fixing pillar tap, capstan head, screw down
high pressure with screws, shanks and back nuts. (i) 15mm dia.
777 M718 C.P. Angle stop cock 15 mm Heavy duty with cap
Providing and fixing chromium plated, bottle trap with
necessary couplings of approved quality for wash basin.
Providing and fixing Urinal of approved quality including connection with trap
and with integral longitudinal flush pipe.(A) Squating plate pattern white
earthenware 550mm
777 M718 C.P. Angle stop cock 15 mm Heavy duty with cap Nos. 18.00 403.39 4.03
MR -1 SS Pipe connection for Angle cock to Urianl for Water spray 300mm Nos. 18.00 300.00 3.00
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
Providing, Installation, testing & commissioning, S. S. sink, single bowl of size
not more than 600 / 450 mm and depth 200 mm with tap point on wall /
counter comprising of Concealed type brackets fixed to wall with adjustable
clamp to push against counter rim. 40 mm heavy plated C.P. waste coupling
1.5 fitting with or without pop-up. Nos. 2.00 2,806.15 28.06
40 mm heavy plated C.P. bottle trap with cleaning eye with extension piece
and wall flange. Painting brackets with two coats of white enamel paint over
one coat of primer.
15 mm CP sink cock wall mounted.
23020B 23.135 Waste Coupling
778 M719 C.P. Bib cock 15 mm Heavy duty with cap
23034 23.12 Rubber plug for sink
Providing, Installation, testing & commissioning,screw down C.P. Water Bib
cocks with wall flange of heavy quality with all accessories, supplied by
Providing, Installation, testing & commissioning,screw down C.P. Angle cocks
with wall flange of heavy quality with all accessories, supplied by owners. For
Geyser, RO, & Washing Machine
Providing, Installation, testing & commissioning, CP brass / S.S. towel rail,
1.8 23025 23.144 600 mm. long and 20 mm. dia., with concealed type brackets fixed, to the wall Nos. 48.00 610.32 6.10
with CP brass screws, etc. complete.
Installation, testing & commissioning, screw-to-wall type toilet paper-roll
1.9 23027 23.146 holder, fixed to the wall with CP brass screws, etc. complete. Nos. 59.00 423.75 4.24
Providing and fixing C.P. brass shower with 15mm inlet.(A) 100mm dia.
Providing and fixing C.P. brass Wall mounted Mixer with Spout & OH shower
pipe connection with necessary parts complete job.
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
B) WATER SUPPLY
Providing and fixing, in proper line and level (with necessary support like,
brick masonry pedestals and battens, if necessary) to floor, approved quality,
heavy duty, White UPVC-Schedule 40 Grade as per ASTM D-1785, of Astral or
equivalent, Open & Conceal piping, complete, including jointing with
2.1 rubbering and airtight joints, with necessary specials, couplers, elbow, equal
tees, tail piece, adapter (both male and female), reducer (single stage, double
stage and triple stage), end cap, fabricated bend, etc., and lubricant or jointing
material, including testing, cutting, making good the wall, ceiling and floor
etc. Testing & installation of pipe lines as per drawing & specification.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR
13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water
following dia. nominal bore tube fittings and clamps including making good
the wall, ceiling and floor etc. complete. All Conceal Pipe line Cold & Hot
Providing & installaing Rubber Insulation 9mm thik for Conceal Hot water
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
Providing, fixing, jointing and testing, heavy quality cast bronze / brass BALL
VALVE / OR WHEEL valves of approved make, including flanges / unions, nuts,
2.3 bolts, washers, etc. complete, as approved by the Architect and Engineer-in-
charge for water supply lines of the following Nominal bore (NB) size:
Providing, fixing, jointing and testing, heavy Quality Gun metal or brass Non
return valve confirming to IS 778, with screwed / flanged ends, 20 Kg/m2 of
approved make, on water supply lines of the following Nominal bore (NB)
C) INTERNAL DRAINAGE
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
Providing and fixing Approved SWR Type B quality, heavy duty, UPVC pipes -
Ring Fit & Self Fit, Supreme or equivalent make, Confirming to IS 13592 &
Fitting confirming to IS 14735 for waste water or soil waste pipe, with
necessary specials, bends, such as `Y' junction, `T' junction (both single and
double), including plugs, shoes, cowls, flange compression type fittings, wall
clips, in proper line and level with necessary support like brackets/clamps,
3.1 clips, RCC or brick pedestals or battens, if necessary, to wall, ceiling and floor,
open or concealed complete jointing with rubberising and airtight joints, with
‘T’ shaped rubber ring, etc., and lubricant or jointing material, including
testing, cutting, making good the wall, ceiling and floor, etc. Testing &
installation of pipe lines as per drawing & specification.
3.1.1 23066 160 mm. (Soil + Waste + Rain Water) - Type B Rmt 660.00 826.12 8.26
3.1.2 23067 110 mm. (Soil + Waste + Rain Water) - Type B Rmt 692.00 847.55 8.48
3.1.3 23004F 23.80 75 mm. - Balcony + Standing Balcony + AC Drain - PVC 10 KG Rmt 48.00 277.46 2.77
3.1.4 23004D 23.80 40 mm for waste water for Sink - PVC 10 KG Rmt 26.00 126.10 1.26
3.1.5 23004C 23.80 32 mm for waste water for Wash basin - PVC 10 KG Rmt 178.00 120.76 1.21
Providing, fixing, jointing and testing IS 14735 for Drain PVC SWR 'P' - traps
of self cleansing design with water seal not less than 50 mm., with or without
vent, cutting chases / hole in floors / slabs and bringing the same in proper
3.2 RA condition and shape after placing the trap in right position in case of
suspended / open plumbing or setting the trap in 1:2:4 CC in case of
concealed plumbing , etc. complete, as required. The trap shall be 'P' type, of
following sizes:
3.2.1 110 x 110 mm OD inlet / outlet Nos. 83.00 600.00 6.00
Providing, fixing, jointing and testing IS 14735 for Drain PVC Multi Floor Trap
7'' HT of self cleansing design with water seal not less than 50 mm., with or
without vent, cutting chases / hole in floors / slabs and bringing the same in
3.3 RA proper condition and shape after placing the trap in right position in case of Nos. 2.00 375.00 3.75
suspended / open plumbing or setting the trap in 1:2:4 CC in case of
concealed plumbing , etc. complete, as required.
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
Providing and fixing Heavy class S.S. grating with Mosquito proof S.S.
strainer of Chilly or equivalent make, as approved, (cockroach trap) including
setting in floor with cement mortor to match with floor finish as per architect
Providing and fixing, PVC cowl, on PVC ventilating pipes and verticals for
3.5 894 M835 soil, waste and rain water Pipes at top level / terrace level, as specified and Nos. 4.00 9.32 0.09
required, etc. complete. 75 OD PIPE
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm
diameter with jali of the following nominal diameter of self cleansing design
with C.I scread down or hinged grating including the cost of cutting and
making good the walls. (for Balcony)
D) EXTERNAL DRAINAGE
Providing laying (to level or slopes) and jointing reinforced concrete Light
duty non-pressure pipes I.S., class NP2 of the following internal diameter with
and butt ends prepared for collar joints including testing, of joints
complete.(B) 150mm
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
Providing, fixing, jointing and testing salt glazed stoneware Gully trap, class
`A', including excavation in all soil types, bailing or pumping out water from
trenches, shoring whenever necessary testing,refilling, in layers ramming &
consolidation, removing away the surplus earth & spoils, dumping it on site or
carting away to lead of 100 meters as directed, incl. embedding the trap in CC
1:2:4, construction of brick masonry chamber, internal clear size 300 mm. x
4.2 300 mm., in brick work 230 mm. thick, in CM 1:4, plastering inside, outside Nos. 40.00 1,234.57 12.35
and all exposed surfaces with CM 1:3, 12 mm. thick, with 300 x 300mm Gully
trap chamber & providing, fixing CI frame and cover 300 x 300 mm.,
weighing together not less than 12.5 Kg., painting of all CI items with 3 coats
of approved bitumastic paint, etc. Complete.of the following diameter size:
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber
and water tight C.I. cover with frame of 300mm x 300mm size (inside) with
standard weight.(i) Square mouth traps.(B) 150mm x 100mm size P or R type
Constructing Inspection chamber 450 x450 x 600 mm clear size in 230 mm
thick brick masonry with cement mortar (1:5) as per ISI with 150 mm thick
1:3:6 P.C.C. bedding, necessary benching in concrete (M-15) and 20 mm thick
smooth cement plaster (1:4) from inside, C.I. steps as necessary and rough
4.3 24014 24.41 cement plaster 20 mm thick in c.m. 1:4 outside, with 50 kg. Full size C.I. Nos. 1.00 2,520.65 25.21
manhole cover and frame (Approved Make) including all excavation in all soil
types, refilling sides in layers with selected earth ramming and consolidating,
removing away surplus soil or dumping it on site as directed (Depth upto
1500 mm to invert).
Extra over and above item no. beyond 1.5 m. depth, for every additional
4.3.1 24017C depth of 0.1 m. or part thereof, for brick masonry Inspection chamber. Nos. 1.00 322.37 3.22
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
Constructing brick masonry chamber for underground C.I. Inspection chamber
and bends with bricks having crushing strength not less than 35Kg/ Cm2 in
C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total
weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and
A frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-
graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished smooth with a floating coat of
neat cement on walls and bed concrete etc. complete.(iii) Inside dimensions
600mm x 850 mm and 450mm deep for pipe lines with three or more inlets.
Extra over and above item no. beyond 1.5 m. depth, for every additional
4.4.1 24017C 24.46 depth of 0.1 m. or part thereof, for brick masonry Inspection chamber. Nos. 5.00 322.37 3.22
Providing and fixing CI Cover manhole frame and cover 455 x 610, light /
medium / heavy weight,Circular / rectangular tested as per IS:1726 for load
bearing.The cover is to be provided with a 5mm thick high abrasion
4.5 177 M118 surface.The cover is to be of double seal type with SS 316 Socket type key Nos. 5.00 955.93 9.56
hole lifting / Rod lifting arrangement . The lifting arrangement is to be closed
from the bottom side. etc. complete as directed by E-I-C.
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse
sand : 4-graded stone aggregate 20mm nominal size) foundation concrete
(1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-Cement : 3-coarse sand) finished with
a floating coat
of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement
:2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth
4.6 24008A 24.27 complete including Nos. 10.00 10,933.41 109.33
curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including
C.I. cover with frame size 560mm diameter total weight of cover and frame to
than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm
thick walls of brick msonry using brick having crushing strength not less than
Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand)(1) A type depth
Metre for 150mm diameter sewer.
(I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M.
4.6.1 24009A 24.28 or Part thereof over item No.24.27 (I) for depth from 0.9M to 1.5M. Nos. 5.00 517.78 5.18
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse
sand : 4-graded stone aggregate 20mm nominal size) foundation concrete
1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside
plastering 15mm thick with Cement Mortar 1:3 (1-Cement : 3-coarse sand)
finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1-Cement :2- Coarse sand :4-
stone aggregate 20mm nominal size) finished smooth complete including
24008B 24.27 curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including Nos. 2.00 19,158.00 191.58
C.I. cover with frame size 560mm diameter total weight of cover and frame to
be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A)
With 230mm thick walls of brick msonry
using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement
Mortar 1:5 (1- Cement: 5-Coarse sand) (2)B type depth 1.50 Metre for 150mm
diameter sewer.
(II) Extra rate for constructing B.B. masonry for every additional depth of 0.1M.
24009B 24.28 GR Part thereof over item No.24.27 (I) for depth from 1.50M. to 2.25M. Nos. 5.00 393.26 3.93
E) UTILITY ITEMS
Installing, testing and commissioing of Pump system comprising of
horizontal Submersible Pumps with SS casing, SS impeller, SS Shaft and
driven by 415 V AC, 3 phase, 50HZ., motor running at 2900 rpm speed and
shall be supplied with all accessories viz., base plate, coupling, motor, VFD
based control panel, dry run & overload protection, cabling up to panel,
earthing, GI medium duty suction, delivery & header pipes, pressure gauge,
pressure switches, pressure transmitter, suction ball valves & delivery ball
valves & check valves etc., complete.
5.1.1 RA 200 lpm., 50mtr., (To GF TO TERRACE TANK) FOR DOMESTIC WATER Set 1.00 50,000.00 500.00
Item Item No. Total Rate with LC
Sr. No. Description of Work Unit Rate Amount in Rs.
Code NOB Quantity 1%
Supply, installation, testing & commissioning of Water level controller for the
5.2 RA OH tanks with switches, hardwares, interlocking with panel, etc.
For Under Ground tank & OH Tank Set 1.00 10,000.00 100.00
5.3 RA Drinking Water Cooller Unit 20 Liter to 30 Liter Set 6.00 40,000.00 400.00
Providing, Supply & Installation of RO System 2000 Liter per Hour with SS
5.4 RA material Pump with SS pipe line & fittings use in Plant. FOR Drinking Water Nos. 1.00 750,000.00 7,500.00
Providing, Supply & Installation of SS 316 Storage tank with SS Stand
Supply, install, test and commission electric storage-type water heater (geyser)
of approved make and capacity 10 litres, complete with thermostat, heating
element, inner tank with corrosion-resistant lining, thermal insulation, outer
casing, temperature and pressure relief valve, non-return valve, isolation valve,
drain valve, wall/floor mounting brackets, electrical connections, safety
controls, and all necessary fittings and accessories, in accordance with
manufacturer’s specifications and relevant standards.
Total Amount for Plumbing Work
Total Amount for Plumbing Work
PROPOSED NEW COMSTRUCTION OF CYCLOTRON AND NUCLEAR MEDICINE BUILDING FOR GCRI AT ASRAWA, AHMEDABAD
BOQ - Fire Fighting System
Total Rate with Total
Sr.No. Item Description Unit Rate
Quantity 1% L.C Amount
(A) Fire Pump Room Acce. (Positive Suction).
Supplying, Installation, Testing and commissioning of electric driven main fire pump suitable for automatic operation
and consisting of following: Horizontal type, centrifugal End Suction pump of cast iron body & bronze impeller
mechanical seal to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of
137m3/Hour@80M. head conforming to IS 1520. The pump shall be coupled to TEFC motor of suitable HP & speed
and complete set shall mounted on common base frame with, coupling, coupling guard, foundation bolts etc. as
required. (Hydrant & Sprinkler System)
Supplying, Installation, Testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation
and consisting of following: Horizontal type, centrifugal End Suction pump of cast iron body & bronze impeller
mechanical seal to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of
137m3/Hour@80M head conforming to IS 1520.The pump shall be coupled to TEFC motor of suitable HP & speed
and complete set shall mounted on common base frame with , coupling, coupling guard, foundation bolts etc. as
Supplying, Installation, Testing and commissioning of Jockey Pump 10.8M3/[email protected] Centrifugal End
4.0 Suction. he pump shall be coupled to TEFC motor of suitable HP & speed and complete set shall mounted on 2.00 Nos. 108,000.00 109,080.00
common base frame with coupling, coupling guard, foundation bolts etc. as required. (Hydrant & Sprinkler System)
Supplying, Installation, Testing and commissioning of cubical type floor mounted power cum control panel complete
5.0 with suitable switch gear, bus bars, relays, contractors, indicating lamps, fuses, instruments manual isolator & auxillary 1.00 Nos. 255,000.00 257,550.00
switch including connections complete as required.
Providing, fixing, testing and commissioning below Cable for Fire Pumps
( Only from Panel to Pumps)
6.1 3 C X 35 Sqmm Alluminium Armoured 60.00 Meter 417.00 421.17
6.2 3 C X 16 Sqmm Alluminium Armoured 60.00 Meter 252.00 254.52
6.3 2 C X 1.5 Sqmm Copper Armoured. 150.00 Meter 143.00 144.43
6.4 Cable Tray 300X50 mm. 20.00 Meter 735.00 742.35
6.5 Cable Tray 150X50 mm. 20.00 Meter 510.00 515.10
Providing, fixing, testing and commissioning of Pressure Gauge with cock & accessories for pumps.The pressure
7.0 gauge shall be approved type. The Gauges with cock shall be constructed of die cast aluminium & stove enameled. 7.00 Nos. 4,050.00 4,090.50
The Gauge shall be of stainless steel bourden type.
Total Rate with Total
Sr.No. Item Description Unit Rate
Quantity 1% L.C Amount
Providing, fixing, testing and commissioning of Pressure switches of diaphram RoomSPDT
operated Acce.type
whetherSuction).
suitable range (15 kg/cm² to 5 kg/cm²) for pump sets with Ball valves, Fittings like unions / collars / reducers etc.
Providing, fixing, testing and commissioning Air vessel fabricated from 10mm MS plate with dished ends,dia of
mm and height 1500 mm with suitable supporting legs, outside painted with one coat of primer and two coats of
9.0 synthetic enamel paint of approved shade, complete with one 25mm dia connection from pump delivery, one 25 mm 2.00 Nos. 48,000.00 48,480.00
drain with valve.The air vessel shall be tested to 1.5 times of working pressure. Complete as per technical specification
& drawing details.
Providing, fixing, testing & commissioning of C.I.Butterfly valve conforming to IS:13095 class PN 16 rating with
Fittings, Flanges, Nutbolts, Washers, Gaskets etc.of size:
10.6 25mm dia.Ball Valve. 4.00 Nos. 1,427.00 1,441.27
10.7 15mm dia Ball Valve. 12.00 Nos. 749.00 756.49
Providing, fixing, testing and commissioning of C.I. Dual plate type Non-Return Valve class PN 16 rating with fittings,
flanges, nutbolts, washers, gaskets etc.of sizes:
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class Heavyduty pipes as per IS:
1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting, screwing, welding etc. and
providing all fittings like flanges, bends, tees, elbows, reducers, clamps, hangers etc. with painting of one coat of
primer and 2 or more coats of synthetic enamel paint of approved make / shade complete as per specification.
Total Rate with Total
Sr.No. Item Description Unit Rate
Quantity 1% L.C Amount
Fire Pump Room Acce. (Positive Suction).
13.0 Providing and fixing, testing and commissioning of "Y" Type Strainer 0.00
(B) Fire Hydrant System & Acce.
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class Heavyduty pipes as per IS:
1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting, screwing, welding etc. and
providing all fittings like flanges, bends, tees, elbows, reducers, clamps, hangers etc. with painting of one coat of
primer and 2 or more coats of synthetic enamel paint of approved make / shade complete as per specification.
Providing, fixing, testing and commissioning of Under Ground M.S. ERW Black C Class Heavyduty pipes as per IS:
15.0 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) with IWL/pypecoat, 4mm thickness wrapping 0.00
and coating and providing all fittings like flanges, tees, elbow, fasteners with all required.
Providing, fixing, testing & commissioning of C.I.Butterfly valve conforming to I.S:13095 class PN 16 rating with
Fittings, Flanges, Nutbolts, Washers, Gaskets etc.of size:
Providing, fixing, testing and commissioning of C.I. Dual plate type Non-Return Valve class PN 16 rating with fittings,
flanges, nutbolts, washers, gaskets etc.of sizes:
(C) Fire Fighting Equipement
Total Rate with Total
Sr.No. Item Description Unit Rate
Quantity 1% L.C Amount
Providing, fixing, testing and commissioning of SS Single Headed Oblique PumpHydrant
Pattern RoomLanding
Acce. (Positive
Valves as Suction).
5290 with 80 mm dia flanged inlet & 63 mm dia female outlet complete with cap and chain etc.
Providing, fixing, testing and commissioning of SS Branch Pipe with nozzle of 20 mm nominal bore outlet suitable to
fit with standard instanteneous type 63 mm dia coupling. As per IS:903.
Providing, fixing, testing and commissioning of 63 mm dia 15m long RRL Hose Pipe with 63 mm dia.Type A Male and
female Stainless Steel couplings duly binded with GI wire, rivets etc. conforming to IS 636 as required.
Providing, fixing, testing and commissioning of weather proof standard fire Hose Cabinet wall mounting type
21.0 Guage. (750 x 600 x 250) having Double Opening with M.S. fabricated stand, necessary locking arrangement by allan 31.00 Nos. 6,900.00 6,969.00
Providing, fixing, testing and commissioning of Wall mounting swing type first aid Fire Hose Reel with drum, hanging
22.0 bracket, 36 M x 25 mm dia high pressure hose reel tubing as per IS:884 with shut nozzle and ball valve and all 24.00 Nos. 8,873.00 8,961.73
required accessories.
Providing, fixing, testing and commissioning of 25 mm dia Air Release Valve and Ball Valve assembly on top of each
riser for Air release system.
Providing, fixing, testing and commissioning of CI Four way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet
with 150 mm dia Butterfly valve blank cap and chain with necessary fittings, flanges, nutbolts etc.
Providing, fixing, testing and commissioning of CI Two way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet
25.0 with blank cap and chain with 100 mm dia Butterfly valve necessary fittings, flanges, nutbolts, gasket and all required 1.00 Nos. 10,719.00 10,826.19
(D) Automatic Fire Sprinkler System.
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class Heavyduty pipes as per IS:
1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting, screwing, welding etc. and
providing all fittings like flanges, bends, tees, elbows, reducers, clamps, hangers etc. with painting of one coat of
primer and 2 or more coats of synthetic enamel paint of approved make / shade complete as per specification.
Total Rate with Total
Sr.No. Item Description Unit Rate
Quantity 1% L.C Amount
Providing, fixing, testing and commissioning of Under Ground M.S. ERW Pump
C Class Acce. (Positive
Heavyduty Suction).
pipes as per IS:
27.0 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And above) with IWL/pypecoat, 4mm thickness wrapping 0.00
and coating and providing all fittings like flanges, tees, elbow, fasteners with all required.
Providing, fixing, testing & commissioning of C.I.Butterfly valve conforming to IS:13095 class PN 16 rating with
Fittings, Flanges, Nutbolts, Washers, Gaskets etc.of size:
(E) Sprinkler System Equipements.
Providing, fixing, testing and commissioning of Sprinkler Alarm valve of cast iron body and brass/bronze working
parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong
29.0 bell to sound continuous alarm when the sprinkler system activates, pressure guages, emergancy releases, strainer, 1.00 Nos. 67,875.00 68,553.75
pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc.
of size 150 mm dia.
Providing and fixing, testing and commissioning of K 5.6 Pendent type Standard response Sprinkler rating of
deg.C. with required accessories.
Providing, fixing, testing and commissioning K 5.6 Upright Sprinkler Standard response rating of 68 deg.C . with
required accessories.
Providing and fixing, testing and commissioning of K 5.6 Side Wall type Standard response Sprinkler rating of
deg.C. with required accessories.
Providing and fixing, testing and commissioning of K 5.6 Pendent type Standard response Sprinkler rating of
deg.C. with required accessories.
Providing, fixing, testing and commissioning of SS Flexible drops 1200mm Long.Unbraided , Maximumm Service
34.0 pressure 175PSI,.Sprinkler Flexible Drop system is a ready to use assembly to fit sprinkler heads in desired location in 1,042.00 Nos. 1,056.00 1,066.56
a suspended ceiling. It easily positions the sprinkler in center of the ceiling tile at a correct height.
Total Rate with Total
Sr.No. Item Description Unit Rate
Quantity 1% L.C Amount
Fire Pump Room Acce. (Positive Suction).
Providing, fixing, testing and commissioning of Flow Indicating Switch with fittings, Flanges, nut-bolts, washers etc. as
per requirement of sizes. 150MM .
Providing, fixing, testing and commissioning of Annunciator panel for flow control switch, providing Audio/Visual
indicating of actuation of automatic sprinkler system for each zone complete as per specifications with provision for
12 zones 'Indication of zone fire, 'Indication of zone fault, 'Fire/Fault hooter, 'Alarm cancel for fire/fault, 'Battery for
Supplying, Installation, Testing and commissioning of 2 C X 1.5 Sqmm Copper Armoured for Flow Switch Cabling
from Announciation panel to Flow Switch.
Providing and fixing, testing and commissioning of Drainning & Testing Assembly 25mm dia with by pass valve, drain
connection & Sight Glass as required.
(F) Fire Extinguishers
Providing & fixing of ABC 6 Kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type,
Pressure Gauge, Controllable discharge mechanism Class A Rating 3A & Class B rating 21B as per IS
Providing and fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 4.5 kg filled with Co2 Gas
40.0 as per IS 15222 with controll discharge mechanis, fitted with Hose & Horn applicable on Class B fire rating 21B 59.00 Nos. 5,270.00 5,322.70
confirms to IS 15683 bearing ISI mark. Co2 cylinder as per IS 7285 .
Providing and fixing, testing and commissioning of Higher capacity Trolley mounted ABC Dry Chemical; Powder type
41.0 ( MAP - 90% ) Fire Extinguisher of capacity 25 kg. confirms to IS 10658, bearing ISI mark, ( Outside Co2 Cylinder 1 3.00 Nos. 8,276.00 8,358.76
Providing and fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas
42.0 as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEY confirms to IS 2878 bearing ISI 3.00 Nos. 19,050.00 19,240.50
mark. Co2 Cylinder as per IS 7285 .
Providing and fixing, testing and commissioning of Higher capacity Trolley mounted Mechanical Foam type Fire
Extinguisher of Capacity 50 liter confirms to IS 13386, bearing ISI mark, (Quoted For 45 ltr)
44.0 Providing, fixing, testing and commissioning of below Auto Glow Signages. 0.00
44.4 In Case of Fire do not use Lift ,Use Staircase 8"x 8" 12.00 Nos. 534.00 539.34
44.5 Fire Extinguisher 8"x 8" 59.00 Nos. 534.00 539.34
44.6 Fire Pump Room 12"X 6" 1.00 Nos. 582.00 587.82
45.0 Civil Work. (In Client Scope) 0.00
Total Rate with Total
Sr.No. Item Description Unit Rate
Quantity 1% L.C Amount
45.1 Providing, fixing, testing and commissioning Hume Pipe NP2 class 400mm dia.Pump Room Acce. (Positive Suction).
Fire Meter 1,419.00 1,433.19
45.3 Excavation & Backfilling Of Soft And Hard soil. 280.00 Cum 750.00 757.50
45.4 Supply, Installaton of Structure Steel Support 2,250.00 Kg 124.00 125.24
APPROVAL FIRE SYSTEM FROM LOCAL FIRE AUTHORITY
46.0 Getting of Fire Fighting System Approval from local fire authority with all other charges and documentations for 1.00 Job 250,000.00 252,500.00
getting No Objection Certificate (NOC, FSPA/Opinion).
Fire Rated Steel Doors with Steel Frames as per BS:476 (20&22), IS 3614 (Part-2) for stability and integrity. pressed
Galvanized steel conforming to IS 277 with the following specification. recommended fire door shell have doors
tested at CBRI for maximum rating of 120 Minutes.
Door frame shall be Single rebate profile of size 105 x 57 mm made out of 1.60mm (16gauge) minimum thick
galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. All provision should be mortised,
drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking
jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered
masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on
the clear masonry opening.
46.1 Door leaf shall be 46mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) 260.00 Sqm 33,000.00 33,330.00
minimum thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for
receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory
prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door
closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be
provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as
per manufacturer's recommendation with a beading and screws from inside. The glass should be 6mm clear
borosilicate fire rated glass of relevant rating of the door.
All doors and frames shall be finished with polyurethane aliphatic grade paint of approved color. The door leaf and
frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation of door
and hardware set as mentioned in the door. Hardware Fittings Make :- Doorma , Geze , Hafales
Total Amount for Fire Fighting System
Total Amount for Fire Fighting System
PROPOSED NEW COMSTRUCTION OF CYCLOTRON AND NUCLEAR MEDICINE BUILDING
FOR GCRI AT ASRAWA, AHMEDABAD
ELV Recap Sheet
SR.NO. DESCRIPTION AMOUNT
1 FIRE DETECTION & ALARM SYSTEM ₹
2 PUBLIC ADDRESS & VOICE EVACUATION SYSTEM ₹
3 IP CCTV SURVILLENCE SYSTEM ₹
4 DATA , VOICE & WIRELESS ACCESS POINT SOLUTION ₹
PROPOSED NEW COMSTRUCTION OF CYCLOTRON AND NUCLEAR MEDICINE BUILDING FOR GCRI AT ASRAWA, AHMEDABAD
ELV Work Abstract Sheet
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
Section 01.00 Fire Detection & Alarm System
'SITC of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with
4 Loops modules and each loop capable of supporting not less than 250 devices
(detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color
LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of
Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft
programmable keys with status indicators for individual triggering of NAC Ouputs,
evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts..
etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM),
power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance
free batteries with automatic charger. The panel shall have seamless integration with
EVAC certified Public Address System and shall be complete with all accessories . EN54 /
Vds/UL Certification.
SITC of Modbus/Bacnet Gateway for Integration with BMS System. The Modbus/BACNET
Gateway shall act as an independent node communicating on the peer to peer network
and shall not be dependant on the Fire Panel CPU for operation (failure of CPU shall not
result in failure of Modbus/BACNET Gateway).
SITC of Fire Graphics software with lifetime license to map, monitor (alarms & faults) &
control all the detector and devices connected to all the Fire alarm panel. The fire Graphics
software shall be loaded on the PC connected to the Fire alarm panel. The GUI based
main network software shall network with other panels on True Peer-to-Peer network. It
3 NSR 1 shall be capable of graphically representing each facility being monitored with floor plans Ea. 350,000 3500.00 353,500.00
and icons depicting the actual locations of the various systems, and / or sensors’ locations.
It shall have the facility to change the sensitivity of any detector.The software shall have
minimum 2000 Points + 20% for future expansion.
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
FIRE WORKSTATION
SITC of Client Workstation with following configurations: Processor – Intel i7 12th Gen,
3.10 GHz,Memory – Minimum 16 GB,Hard disks – 512 GB SDD ,compatible OS for VMS,
4 NSR 1 Network Card – 10Gbit/s network card,NVIDIA Graphic card of minimum 4 GB, Dual Ea. 225,000 2250.00 227,250.00
Port card for connecting minimum of 2 LCD Screen complete with all accessories
required to complete the installation as per project requirements.
SITC of Active Repeater panel to be connected peer to peer with Main Fire Alarm panel.
Accept, Reset functions shall be possible from the repeater panel. The user interface of
5 NSR 1 Repeater Panel shall be identical to the Fire alarm Panel. All other specification shall Ea. 125,000 1250.00 126,250.00
remain unchanged like FACP. EN54 / Vds/UL Certification.
SITC of Addressable Heat Detectors with combination of fixed type and rate of rise of
temperature feature. Detetctor should have inbuilt isolators as per NFPA 72 style 7 wiring
requirements and have an option of both soft & hard addressing. Detector should
6 NSR 30 monitor Electromagnetic interference and report to the panel - current and average Ea. 3,850 38.50 3,888.50
values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/
certification.(Detectors without Inbuilt Isolators may be considered with an additional
Isolator Module per detector) EN54 / Vds/UL Certification
SITC of Intelligent Addressable Multicriteria detector with a combination of Optical and
Thermal including mounting base, auto addressing feauture as required. Detetctor
should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements (one for
incoming and one for outgoing line) for maintaining operational availability of all
7 NSR 970 elements in the loop in the event of a short circuit and to meet style 7 requirements. High Ea. 3,900 39.00 3,939.00
resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005
.Detector should monitor Electromagnetic interference and report to the panel - current
and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL
SITC of Response indicator for mounting on false ceiling at the entries of the cabin for
8 NSR 485 indicating the operation for detectors in the above areas including Backbox Ea. 250 2.50 252.50
SITC of Addresaable Beam detector incuding mounting base along with Interface module
to direct connnect to the loop , having a coverage area with a distance of min. 10 m and
9 NSR 4 max. 100 m with extra width of up to 14 m ,Operating temperature range: -20 C to +55 C, Ea. 65,000 650.00 65,650.00
Response sensitivity of 40%. Shall be EN54/ VDs/ certification.
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
SITC of Addessable WEATHER PROOF(Outdoor) Manual call point with IP rating of IP
and with inbuilt isolators as per NFPA 72 style 7 wiring requirements, with flexible network
10 NSR 28 structures & necessary fixing arrangements with key complete as required. Shall be EN 54 Ea. 8,500 85.00 8,585.00
/ Vds/UL Certification.
SITC of Addressable Loop Powered Indoor Sounder cum Strobe with inbuilt isolators as
per NFPA 72 style 7 wiring requirements & with 32 different tone variants selection
11 NSR 28 options & adjustable sound pressure by 5 levels, the sound pressure 92.1 dB(A), with Ea. 6,500 65.00 6,565.00
flasher having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should be
programmed from the panel. Shall be EN54 / Vds/UL Certification.
SITC of Loop Powered Voice Sounder Indoor with inbuilt isolators as per NFPA 72 style
wiring requirements & with 32 different tone variants selection options with 4 different
12 NSR 28 voice messages in 7 languages, the maximum sound pressure 95.4 dB(A) should be Ea. 12,500 125.00 12,625.00
programmed from the panel. Shall be EN54 / Vds/UL Certification.
SITC of Addressable Control Module with inbuilt isolators as per NFPA 72 style 7 wiring
requirements with a maximun switching current of 1A @ 30V DC. Control module shall be
13 NSR 28 used for to activate Conventional Sounder cum Strobe/Sounders/Strobes. Shall be EN54/ Ea. 3,850 38.50 3,888.50
Vds Certification/UL
SITC of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style
wiring requirements with a maximun switching current of 1A @ 30V DC. Relay Control
14 NSR 42 module shall be used for emergency control functions including shutting down Fire Ea. 3,850 38.50 3,888.50
dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access
control doors etc.. Shall be EN54/ Vds Certification/UL
SITC of Addressable Monitor Module with one input & one output contacts, with inbuilt
isolators & with 2 monitoring features, monitoring of a line with EOL resistor ,Potential
free contact monitoring with Inbuilt isolators for flow switches, Panic Bars & other Third
Party Inputs. Shall be EN54 / Vds/UL Certification.
SITC of Fire Fighter's Master panel along with Master Handset as per the Specifications.
Shall be UL Listed
17 NSR 28 SITC of Fire fighters telephone jack as per the specifications. Shall be UL Listed Ea. 5,500 55.00 5,555.00
Supplying of Red colored Fire fighters telephone Handset as per the specifications. Shall
SITC of 2 X 1.5 Sq.mm Fire Survival Armored Cable, for Fire Aalrm Device Looping & Power
19 NSR 12,000 Supply. Outer Sheth Red color. Mtrs. 155 1.55 156.55
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
Section 02.00 Public Address & Voice Evacuation System
SITC of IP based Digital Public Address and Emergency Sound System Controller certified
to International standards of Emergency Sound System EN 54 and ISO 7240‑16, marked
for CE and compliant with the RoHS directive. The system shall be fully IP-network based
and all system devices shall communicate via IP, using an Audio over IP (AoIP) protocol
that supports standards AES67 for audio and using AES70 for control with optional
encryption and authentication to prevent unauthorized access, misuse and modification of
data.It shall be capable of receiving Dante and AES67 audio streams. The audio part shall
support Layer 3 connections via routers between subnets with latency of less than 10ms
and synchronized outputs.The control data part shall be guaranteed by Transmission
20 7-10-132 1 Control Protocol (TCP) Layer 4. The system shall support >100 simultaneous channels for Ea. 607,662 6076.62 613,738.62
music routing and making calls. A system based on a single system controller shall
support at least 120 system devices and 500 zones.The system controller shall dynamically
assign network audio channels for audio routing between system devices across multiple
subnets. The system controller shall have dual power supply inputs and power supplies. It
shall keep an internal log of fault events and call events.The system controller shall
provide a secure TCP/IP open interface for remote control and diagnostics.The system
controller shall provide front-panel LED indications for the status of power supplies and
the presence of faults in the system upto 2000 faults and provide additional software
monitoring and fault reporting features.
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of The desktop call station with extension keypad with 12 fully programmable keys
for zone section and PA system operation. The call station and the keypad shall be
certified for EN 54‑16 and ISO 7240‑16, marked for CE and be compliant with the RoHS
directive.Desktop housing with goose neck microphone. 4.3" full‑color capacitive touch
display. Graphical user interface for optimum user guidance and feedback.Status and fault
21 7-10-133 1 indicators for voice alarm purposes.Dual Audio over IP‑network ports for redundant Ea. 526,672 5266.72 531,938.72
network. The audio over IP should comply AES 67 standard for audio and AES 70 for
control with optional encryption and authentication to prevent unauthorized access,
misuse and modification of data. [Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
SITC of IP based Digital Class-D multi channel Amplifier 600W each with 8 channels,The
amplifier shall adapt the maximum output power of each amplifier channel to its
connected loudspeaker load, with free assignable output power per channel.EN
certified and ISO 7240‑16, marked for CE and compliant with the RoHS directive.The
amplifier shall have a built-in independent spare amplifier channel for automatic fail
over.The amplifier shall provide an interface for control data and multi-channel digital
audio over IP using dual Ethernet ports for redundant network connection, supporting
RSTP and loop-through cabling, with automatic fail over to an analog lifeline input.
The amplifier shall have dual power supply inputs and power supplies.All amplifier
channels shall have independent A/B zone outputs with support for class-A loudspeaker
All amplifier channels shall supervise the integrity of connected loudspeaker lines without
interruption of audio distribution.The amplifier shall provide front-panel LED status
indications for the network link, ground fault, power supplies and audio channels, and
provide additional software monitoring and fault reporting features. Audio‑over‑IP, using
the high‑quality digital audio interface, compatible with AES67 and AES 70 standards with
optional encryption and authentication to prevent unauthorized access, misuse and
modification of data using an uncompressed, high-definition digital audio format with 24-
bit sample size and 48 kHz sample rate.Digital signal processing on all amplifier channels,
including equalization, limiting and delay, to optimize and tailor the sound in each
loudspeaker zone. [Approved by Competent Authority i.e. not Below the rank of Executive
SITC of Ceiling loudspeaker 6W, ABS with clamps
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of ABS back box [Approved by Competent Authority i.e. not Below the rank of
Executive Engineer ]
SITC of Cabinet loudspeaker, 15W, black High-fidelity music and speech reproduction
Selectable 8 ohm, 70 V and 100 V inputs
Compact yet robust ABS enclosure
25 7-10-103 0 Supplied with adjustable mounting bracket Ea. 9,288 92.88 9,380.88
Complies with international installation and safety regulations
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
26 NSR 1 SITC of Audio Source to play audio using Bluetooth, USB, DVD, FM, IP Streaming. Ea. 195,000 1950.00 196,950.00
SITC of 2 X 1.5 Sq.mm Fire Survival Armored Cable, for PA Device Looping & Power
Supply. Outer Sheth Grey color.
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
SITC of 42U 800mm X 800mm, equipment rack with all mountig accesories, power strip
2nos with 10 sockets M type, caster wheel with lock, front glass & rear perforated door,
28 NSR 1 fan unit on top with 4 fans, compleate with all required shelves for mounting. Ea. 52,000 520.00 52,520.00
Section 03.00 IP CCTV SURVILLENCE SYSTEM
INDOOR IR DOME CAMERA
SITC of Progressive scan CMOS 4MP, 1/2.8”, 2048 x 1536, IP Bullet IR, Cameras , Up to
fps @ 1080P, Progressive scan CMOS, 3 to 10mm Verifocal, Colour: 0.08 lux at 33ms, B/W:
29 NSR 95 0.015 lux at 33ms, and 0 Lux with IR On Range: Adaptive IR Illumination 50 Mtrs, ONVIF Ea. 22,950 229.50 23,179.50
Profile S, Profile G, and Profile T Conformant, IK10,BI Directional audio, UL listed, IP66
Rated casing (polyester polycarbonate blend) etc. PoE+ Power.
OUTDOOR IR BULLET CAMERA
SITC of Progressive scan CMOS 4MP, 1/2.8”, 2048 x 1536, IP Bullet IR, Cameras , Up to
fps @ 1080P, Progressive scan CMOS, 3 to 10mm Verifocal, Colour: 0.08 lux at 33ms, B/W:
30 NSR 5 0.015 lux at 33ms, and 0 Lux with IR On Range: Adaptive IR Illumination 50 Mtrs, ONVIF Ea. 24,150 241.50 24,391.50
Profile S, Profile G, and Profile T Conformant, IK10,BI Directional audio, UL listed, IP66, IP67
Rated casing (polyester polycarbonate blend) etc. PoE+ Power.
INDOOR IR BULLET CAMERA
SITC of Progressive scan CMOS 4MP, 1/2.8”, 2048 x 1536, IP Bullet IR, Cameras , Up to
fps @ 1080P, Progressive scan CMOS, 3 to 10mm Verifocal, Colour: 0.08 lux at 33ms, B/W:
31 NSR 12 0.015 lux at 33ms, and 0 Lux with IR On Range: Adaptive IR Illumination 50 Mtrs, ONVIF Ea. 26,150 261.50 26,411.50
Profile S, Profile G, and Profile T Conformant, IK10,BI Directional audio, UL listed, IP66, IP67
Rated casing (polyester polycarbonate blend) etc. PoE+ Power.
OUTDOOR PTZ CAMERA
SITC of Progressive scan CMOS 2MP, 1/3”, 1920 x 1080, IP PTZ Speed Dome Cameras, Up
32 NSR 0 to 30 fps @ 1080P, 36X Optical Zoom & 10X Digital Zoom, 0.3 lux at 33ms, B/W: 0.1 lux at Ea. 140,500 1405.00 141,905.00
33ms, Smoked Dome, ONVIF Profile S and Profile G Conformant, IK10, UL listed, IP66,
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
NETWORK VIDEO RECORDER
SITC of network video recoreder of 64 Channel, for camera recording @ 25fps, full HD for
30 Days compresion H.265.
SITC of Client Workstation with following configurations: Processor – Intel i7 12th Gen,
3.10 GHz,Memory – Minimum 16 GB,Hard disks – 512 GB SDD ,compatible OS for VMS,
34 NSR 2 Network Card – 10Gbit/s network card,NVIDIA Graphic card of minimum 4 GB, Dual Ea. 225,000 2250.00 227,250.00
Port card for connecting minimum of 2 LCD Screen complete with all accessories
required to complete the installation as per project requirements.
SITC of wall mount 55" Professional Display unit Full HD/4K high resolution diplay with
3XHDMI ports, 2XUSB Ports, 1X3.5mm Jack, 1XExternal IR receiver etc.
Section 04.00 DATA , VOICE & WIRELESS ACCESS POINT SOLUTION
SITC of CAT6 UTP 23AWG Solid: Per Meter
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
1-4- Supplying and Laying of 0.5 mm dia Annealed copper Jelly filled 50 pair armoured
37 300 telephone cable with suitable aesthetic dressing. (b) Armoured [Jelly Filled] Mtr. 442 4.42 446.42
SITC of O. F.Cable 06F Outdoor - Armoured Unitube SM - HDPE Sheath [Approved by
38 7-13-1 1,000 Competent Authority i.e. not Below the rank of Executive Engineer ] RMT 50 0.50 50.50
SITC of Jack Cat 6 Keystone UTP
39 7-13-8 300 [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Ea. 160 1.60 161.60
SITC of Face Plate - Dual (Keystone Jack,square)
40 7-13-7 130 [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Ea. 100 1.00 101.00
SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U' Snag less
41 7-13-12 426 [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Ea. 199 1.99 200.99
SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U' Snag less
42 7-13-11 180 [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Ea. 155 1.55 156.55
SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded
43 7-13-10 13 [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Ea. 4,357 43.57 4,400.57
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
SITC of 24 x 10/100/1000BASE-T PoE ports
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
Optional “standard mode” or “surveillance mode” management user interface
193 W PoE budget
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of 24 x 10/100/1000BASE-T ports
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
Optional “standard mode” or “surveillance mode” management user interface
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of 20 x SFP ports
4 x Combo 10/100/1000BASE-T/SFP ports
4 x 10G SFP+ ports
6 kV surge protection on all RJ-45 access ports
Switch Resource Management (SRM) for flexible management of system resources
46 7-13-18 0 Redundant Power Supply (RPS) support Ea. 641,524 6415.24 647,939.24
MPLS L2VPM/L3 VPN support
Full L3 routing protocol support including OSPF, BGP, and ISIS for IPv4/IPv6
SDN-enabled switch, compatible with Openflow
10-GbE SFP+ to SFP+ 1M Direct Attach Cable [Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
SITC of Maximum distance of up to 10 km
Single-mode fiber
Duplex LC connector
MSA, RoHS-compliant [Approved by Competent Authority i.e. not Below the rank of
Executive Engineer ]
Supply, Installation, Testing & Commissioning Wifi6 Access Point controller for controlling
48 NSR 1 upto 100WIFI access point & 500 Users simultaniously. Ea. 550,000 5500.00 555,500.00
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
Supply, Installation, Testing & Commissioning Wifi6 Access Point Having 2.4GHz &
5.0GHz Dual Band 802.11ac Wave2 Access Points with 2x2 MU-MIMO, 2 Spatial Streams
49 NSR 60 802.11b/g/n (300Mbps) and 802.11ac (867Mbps); AP should be upgradable to Integrated Ea. 65,000 650.00 65,650.00
Bluetooth radio; AP should have 1 Gigabit port, 1 Management Console Port with License,
Embaded control for security policy is must.
SITC of LIU 12 PORT Rack Mount - Loaded (LC) SM
50 7-13-2 10 [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Ea. 6,833 68.33 6,901.33
SITC of PIGTAIL LC SM SIMPLEX LENGTH- 1m
51 7-13-3 120 [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Ea. 772 7.72 779.72
SITC of PATCH CORD LC-LC SM DUPLEX LENGTH- 3m
52 7-13-4 60 [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Ea. 1,883 18.83 1,901.83
SITC of Digital / PCM / TDM EPABX System having SMT design, system with flexible
universal slots. Inbuilt Auto attendant facility, Minimum 15 Ea. conference, Analog
extension line, Calling GSM, E&M line, PRI / EI & VOIP program me through Analog
telephone digital key from Ethernet, public address cord, shall have unrestricted
simultaneous dialing facility,
QSIG protocol on PRI, 95 / STD / ISD / Local-Locking, Class of Service, Quick Dial-Single
Digit dialing of any two external number, Once only ring device, Chairman / Secretary - Do
not disturb Facility, Power Down Mode, Hot Line, Hot Outward Dialing, Day Night Mode,
Auto Call Back, Barge-in, Call Pick Up & Call Transfer, Call transfer while Ringing with
Voice Guide System, (DISA), Caller ID (CLI), CLI Base ECF, CLI Base routing Internet Ready
Port, External Music Port, Call Budgeting, Call Most Calculation (ASMDR), DID Direct
Inverse Dialing, External Music Input, Fax Homing, Global Directory Printing with following
capacities [[Approved by Competent Authority i.e. not Below the rank of Executive
Engineer ], [E] No of Extension 128, No of Junctions 24, No of expandable ports :
Operators Console - 01 Compatible : ISDN and Networking
Providing and erecting add on Digital line card suitable for existing system of following
54 3 ports [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] Ea. 13,424 134.24 13,558.24
SITC OF 50 Port Telephone Patch panel with RJ-45/12 termination, compleate with
mounting accesories.
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
Supplying & erecting push button type telephone instrument having speaker phone Caller
ID & speaker phone with one touch memory (min.6 nos.)& 99 memories with display
system Single line [[Approved by Competent Authority i.e. not Below the rank of
Executive Engineer ]
57 NSR 3 SITC OF 42U, 800mm x 1000mm server rack, with all accessories Ea. 52,000 520.00 52,520.00
58 NSR 7 SITC OF 15U, 500mm x 550 mm Wall mount network rack with all accessories Ea. 15,000 150.00 15,150.00
BMS Central Processing Equipment (Workstation) with Color Monitor
Supply, Installation, Testing & Commisioning of Standalone commercialgrade
Workstation, features latest Intel i7 12th Gen , 12th Gen processorwith3.0 GHz or higher,
59 NSR 1 16 GB RAM,1TBHardDiskdrive,DVDR/RW,DualLANcard, 2GBDualVideo Ea. 150,000 1500.00 151,500.00
Accelerator,DualMonitorsupport,2Ea.spare USBports, Optical Mouse& keyboard,2 Serial,
parallel,Windowsbased withstandard MSoffice package, Latest
Norton/MacAfeevirusvaccinesuitableforoperationon230 voltsA/C.
50Hz,allasperspecificationsasrequired.Energy star rating ispreferred.
Theprintersshallbesuitablefortrendlog,summary,totalizerlogging,recordingalarmsandprovid
ingsystemreports. A hardcopymulti-colorgraphicslaserprinter (compactable A4printer)
forrecordinggraphicdisplaysandassociated dynamic data.
OFC Ethernet Switches (One number Hub/Switch not less than 24-port 10/100 Duel Speed
port-up to 200Mbps) Ethernet switches, 100 base TX, 8 port Miscellaneous Network
Color note book with built-in modem for remote dialing-in for use as a portable
programming and operational (POT) tool to develop, debug, and monitor ladder logic
programs, and to monitor data tables with high quality color LCD, 14” graphic display
62 NSR 1 which supports 256 colors, state of art min I7, 3.0 GHz or above and be complete with Ea. 145,000 1450.00 146,450.00
min standard 8 GB RAM, Min 1TB hard disk capacity withhighspeed diskaccess,
highspeed HDD-R/RW, and with 82-key sculpturedkeyboard (101
keyboard compatible),USB mouse, window 10 OS, Wi-Fi enabled with back pack/hand bag
etc. as per specification and having weight less than 2 Kg.
BMS Software for E&MforHMI,Event& Alarm, PLC LogicDevelopmentandDebuggingetc.
asperspecificationand
support dual display workstation.
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
DDC/PLC PANEL & IO MODULES.
“Non – SIL RPU/PLC/DDC for SCADA System should have Digital Input, Digital Output,
Analog Input and Analog Output Modules integrated to CPU module along with other
required interface or system module for integration of field signals; should capable of
standalone monitoring and control function irrespective to server communication
interface; should fully equipped with dual Power Supply module, OFC Converter,
deviceprotection, all types of requiredtransducers and interface terminals and wiring and SET 0.00 0.00
other devices as required to meet tender specification & functional requirement.
PLCProgrammedsoftwareforPLClogicdevelopmentanddebuggingforusewithcompatiblePer
sonalComputer, Manufacturer shall provide.
IntegratedRemoteI/OBusManager,96-
wordBasememory,1000I/Ocapacity,64processchannels:1Nos,6slotCPU rack.
Al Module as per Signal list with necessary spare I/O consideration. (As per I/O
DI Module as per Signal list with necessary spare I/O consideration. (As per I/O
DO Module as per Signal list with necessary spare I/O consideration. (As per I/O
AO Module l as per Signal list with necessary spare I/O consideration. (As per I/O
68 NSR 1 RS-485 Communication module for integration with 3rd party & EMS. Lot. 150,000 1500.00 151,500.00
70 NSR 6 Level Transmitter for water liquid level sensing. Ea. 24,500 245.00 24,745.00
71 NSR 6 Immersion type Temperature Sensor, thermowell type Ea. 4,500 45.00 4,545.00
72 NSR 10 Space / Room Temperature Sensor + RH Ea. 12,500 125.00 12,625.00
73 NSR 1 Outdoor Temperature Sensor + RH Ea. 25,000 250.00 25,250.00
74 NSR 10 Indoor IAQ Sensor Ea. 35,000 350.00 35,350.00
75 NSR 30 Current Switch for Status monitoring. Ea. 3,500 35.00 3,535.00
CONTROL CABLE WIRING
600/1000V grade armored XLPE FRZH Copper (Cu) conductor STP cable screened control
cables on existing 0.00 0.00
trays/walls/columns/indoor/trenchesincludingthe.costofsupportswithsuitableclamps,cable
gland,hooks,boltsetc.and including the cost of proper dressing of cable.
76 NSR 2,000 1 Pair Cable * 1.0 SQ.mm RMT 80 0.80 80.80
77 NSR 800 2 Pair Cable * 1.0 SQ.mm RMT 90 0.90 90.90
78 NSR 600 4 Pair Cable * 1.0 SQ.mm RMT 125 1.25 126.25
79 NSR 300 6 Pair Cable * 1.0 SQ.mm RMT 145 1.45 146.45
Rate SOR Rate With 1% Estimated
Number SOR NO Qnty may be Item Descriptionan Unit 1% Lc.
In Figure L.C. Amount
SITC of CAT6 UTP 23AWG Solid: Per Meter
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Total Amount for ELV Work
Total Amount for ELV Work
PROPOSED NEW COMSTRUCTION OF CYCLOTRON AND NUCLEAR MEDICINE
BUILDING FOR GCRI AT ASRAWA, AHMEDABAD
Electrical Recap Sheet
SR.NO. DESCRIPTION AMOUNT
1.0 POINT WIRING ₹
2.0 CABLES & ACCESSORIES ₹
4.0 SWITCHGEARS & DISTRIBUTION BOARDS ₹
5.0 LIGHT FIXTURE AND FAN ₹
6.0 EARTHING AND LIGHTINING PROTECTION ₹
7.0 UPS SYSTEM ₹
8.0 WATER COOLER & AC & PUMP ₹
10.0 TRANSFORMER & SUBSTATION EQUP. ₹
11.0 LIAISONING WORK ₹
13.0 TTA PANEL ₹
PROPOSED NEW COMSTRUCTION OF CYCLOTRON AND NUCLEAR MEDICINE BUILDING FOR GCRI AT ASRAWA, AHMEDABAD
Electrical Abstract Sheet
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
SECTION 1.00 POINT WIRING
Point wiring in Copper (Modular)
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand
1 1-2-1-F 1,500 copper wires up to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push & accessories and earth continuity of Pt. 481 4.81 485.81
following type, erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat. III
Point wiring for secondary light point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires, in below type of pipe to be erected complete with earth continuity and necessary connection with primary light with
2 1-1-4-F 2,000 accessories erected on Metal / PVC / wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open / concealed wiring. with Pt. 166 1.66 167.66
necessary Lamp holder / ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected with 6A Modular type switch and hum free EME step type electronic fan regulator mounted
3 1-2-2-F. 300 and accessories with earth continuity of following type erected on PVC / Metallic/Wooden box, single mounting base frame covered with Pt. 668 6.68 674.68
textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box
4 1-2-3-I-F 800 covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. Pt. 505 5.05 510.05
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box
5 1-2-3-II-F 300 covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. Pt. 738 7.38 745.38
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box
1-2-3-III- covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories.
F [III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame
7 1-2-4. 1,800 covered with textured / metallic/white front plate modules erected on / in wall / ceiling with following type accessories Cat-III Pt. 255 2.55 257.55
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires erected in below type of pipe with 6A Modular type switches and following type of accessories erected on PVC /
8 1-2-5-F. 10 Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling as per pipe Pt. 598 5.98 603.98
erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured /
9 1-2-6-4. 50 metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge. Ea. 159 1.59 160.59
(4) TV Co-axial Socket outlet Cat-III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured /
10 1-2-6-7. 50 metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge. Ea. 25 0.25 25.25
(7) Blank Plate Single Cat-III
11 1-6-11. 5 Call bell gong type suitable for 230 volts, 50 c/s. AC supply complete Erected Ea. 42 0.42 42.42
12 1-6-12. 5 Decorative call bell Ting-tong box type 250 volts complete erected Ea. 71 0.71 71.71
Conduits & Pipes
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary
PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary
14 1-3-2-b. 3,000 PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed Mtr. 32 0.32 32.32
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary
15 1-3-2-c. 100 PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed Mtr. 54 0.54 54.54
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes.
Supplying & erecting UPVC Mini trunking (PVC Casing-n-Capping) having double-locking arrangement with grooves, trunking of size not below
17 1-3-5-2. 50 mm in height as per IS with accessories of PVC/Resin polypropylene not below 1.8 mm thick duly sealed in joint & erected on wall / ceiling of following Mtr. 31 0.31 31.31
size . ..(2) 25 mm
Supplying & erecting UPVC Mini trunking (PVC Casing-n-Capping) having double-locking arrangement with grooves, trunking of size not below
18 1-3-5-3. 50 mm in height as per IS with accessories of PVC/Resin polypropylene not below 1.8 mm thick duly sealed in joint & erected on wall / ceiling of following Mtr. 36 0.36 36.36
size .(3) 32 mm
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free and flame proof
confirming BS with necessary end caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following
(1) 75 mm x 50 mm trunking
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free and flame proof
confirming BS with necessary end caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following
(2) 100 mm x 50 mm trunking
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected
21 1-4-1. 5,000 concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of Mtr. 62 0.62 62.62
(A) With medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm (FRLS)
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected
concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of
22 1-4-1. 25,000 following size Mtr. 82 0.82 82.82
(A) With medium class Rigid PVC pipe and accessories
(b) 2 wire 2.5 sq. mm (FRLS)
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected
in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size.
23 1-4-2. 25,000 (a) with medium class Rigid PVC pipe and accessories Mtr. 111 1.11 112.11
(a) 2 wire 4 sq. mm
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam
PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation.
SECTION 2.00 CABLES & ACCESSORIES
ARMOURED ALLUMINIUM CABLES.
25 4-3-3. 1,000 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or Mtr. 1,394 13.94 1,407.94
in existing trench / pipe of following size of cables
(J) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or
26 4-3-3. 300 in existing trench / pipe of following size of cables Mtr. 896 8.96 904.96
(H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or
27 4-3-3. 300 in existing trench / pipe of following size of cables Mtr. 535 5.35 540.35
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or
28 4-3-3. 50 in existing trench / pipe of following size of cables Mtr. 486 4.86 490.86
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or
29 4-3-3. 200 in existing trench / pipe of following size of cables Mtr. 375 3.75 378.75
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or
30 4-3-3. 50 in existing trench / pipe of following size of cables Mtr. 282 2.82 284.82
(C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or
31 4-3-5. 1,500 in existing trench / pipe of following size of cables Mtr. 152 1.52 153.52
(A) 4 core 16 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on wall with necessary
32 4-3-4. 1,500 clamps or in existing trench / pipe of following size of cables Mtr. 139 1.39 140.39
c) 4 Core 10 Sq.mm.
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size.
(a)7 core 1.5 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary
34 4-4-4. 500 clamps or in existing trench / pipe at road crossing or floor of following size of cables. Mtr. 361 3.61 364.61
(B) 4 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary
35 4-4-4. 500 clamps or in existing trench / pipe at road crossing or floor of following size of cables. Mtr. 505 5.05 510.05
(C) 4 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in
36 4-4-2. 100 existing trench / pipe at road crossing or floor of following size of cable. Mtr. 285 2.85 287.85
(B) 3 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in
37 4-4-2. 100 existing trench / pipe at road crossing or floor of following size of cable Mtr. 392 3.92 395.92
(C) 3 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in
38 4-4-3. 100 existing trench / pipe at road crossing or floor of following size of cables. Mtr. 2,176 21.76 2,197.76
(B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in
39 4-4-3. 100 existing trench / pipe at road crossing or floor of following size of cables. Mtr. 7,498 74.98 7,572.98
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary
40 4-4-4.(A) 100 clamps or in existing trench / pipe at road crossing or floor of following size of cables. Mtr. 789 7.89 796.89
(C) 4 core 10 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables.
(A) 2 to 4 core 2.5 / 4 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails,
39 4-6-1. 100 insulating tape etc for following size of cables. Ea. 38 0.38 38.38
c) 2 to 4 Core 10 Sq.mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails,
40 4-6-1. 100 insulating tape etc for following size of cables. Ea. 47 0.47 47.47
d) 2 to 4 Core 16 Sq.mm
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete
41 4-6-3. 4 with out going tails, insulating tape etc for following size of cables. Ea. 75 0.75 75.75
(B) 3 & 1/2 core 35/50 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails,
42 4-6-3. 15 insulating tape etc for following size of cables. Ea. 102 1.02 103.02
(C) 3 & 1/2 core 70 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails,
43 4-6-3. 4 insulating tape etc for following size of cables. Ea. 130 1.30 131.30
(D) 3 & 1/2 core 95 Sq. Mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails,
44 4-6-3. 20 insulating tape etc for following size of cables. Ea. 139 1.39 140.39
(E) 3 & 1/2 core 120 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails,
45 4-6-3. 20 insulating tape etc for following size of cables. Ea. 236 2.36 238.36
(G) 3 & 1/2 core 185 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails,
46 4-6-3. 50 insulating tape etc for following size of cables. Ea. 278 2.78 280.78
(I) 3 & 1/2 core 300 Sq. mm
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
(B) 10 Sq.mm (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to
48 4-7-1. 185 switchgear terminals with brass/cadmium plated nut bolts in an approved manner. Ea. 15 0.15 15.15
C) 16/25 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to
49 4-7-1. 20 switchgear terminals with brass/cadmium plated nut bolts in an approved manner. Ea. 20 0.20 20.20
(D) 35/50 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to
50 4-7-1. 55 switchgear terminals with brass/cadmium plated nut bolts in an approved manner. Ea. 25 0.25 25.25
(E) 70 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to
51 4-7-1. 20 switchgear terminals with brass/cadmium plated nut bolts in an approved manner. Ea. 40 0.40 40.40
(F) 95 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to
52 4-7-1. 50 switchgear terminals with brass/cadmium plated nut bolts in an approved manner. Ea. 45 0.45 45.45
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to
53 4-7-1. 65 switchgear terminals with brass/cadmium plated nut bolts in an approved manner. Ea. 80 0.80 80.80
( I ) 185 Sq.mm. (ISI MARKED)
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to
54 4-7-1. 200 switchgear terminals with brass/cadmium plated nut bolts in an approved manner. Ea. 98 0.98 98.98
(K) 300 Sq.mm. (ISI MARKED)
Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to
55 4-7-2. 35 switchgear terminals with brass/cadmium plated nut bolts in an approved manner. Ea. 8 0.08 8.08
(A) 1.5/2.5 to 6 Sq.mm (ISI MARKED)
Providing and erecting Epoxy Outdoor / Indoor end termination Kit suitable for LT PVC insulated armoured cable1.1 KV grade complete with ferrule
56 4-8-3. 10 bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cables of following size. Ea. 378 3.78 381.78
Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making
the surface as normal ground.
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting
accessories of same material at required depth for laying of cable. below ground / road surface for enclosing cable
(d)120 mm inner dia.
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting
accessories of same material at required depth for laying of cable. below ground / road surface for enclosing cable
(A)50 mm inner dia
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be
fabricated of double bended channel section longitudinal members with single bended Channel section. Rungs of members welded to the base of the
60 .4-11-9 300 longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish Mtr. 810 8.10 818.10
plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge..
13 -600 X 100 X 2 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from pre- galvanized sheet steel. The cable tray should be bended as per IS
2062/1079 . with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
150 X 50 X 1.5 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from pre- galvanized sheet steel. The cable tray should be bended as per IS
2062/1079 . with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
300 X 50 X 1.5 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from pre- galvanized sheet steel. The cable tray should be bended as per IS
2062/1079 . with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
100 X 50 X 1.5 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from pre- galvanized sheet steel. The cable tray should be bended as per IS
2062/1079 . with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
50 X 50 X 1.5 mm Thick
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from pre galvanized sheet steel. The Junction should be
bended as per IS 2062/1079. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge..
150 X 50 X 1.5 mm Thick 90° Elbow
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from pre galvanized CR sheet steel. The Junction should be
bended as per IS 2062/1079. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge..
300 X 50 X 1.5 mm Thick 90° Elbow
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from pre galvanized CR sheet steel. The Junction should be
bended as per IS 2062/1079. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge..
100 X 50 X 1.5 mm Thick 90° Elbow
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from pre galvanized CR sheet steel. The Junction should be
bended as per IS 2062/1079. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge..
50 X 50 X 1.5 mm Thick 90° Elbow
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels,
sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer
in charge with necessary grouting, cementing, plastering & finishing complete.. (for Cable Tray support & PANEL)
SECTION 3.00 SENSOR
SENSOR FOR -Open workstation, Cabins,TOILETS:
69 3-17-2. 15 Providing & erecting stand alone ceiling mount PIR motion Sensor with ABS Housing single phase AC operation. Complete with Dual element NOS 4,323 43.23 4,366.23
pyroelectric sensor, Digital Signal Processing Detection Range 14 feet at 10 feet height, angle 360 degree, RFI and EMI immunity, Detects motion in it's
coverage area. Multipurpose device can be used as security device, an energy saving device, an automatic switch. Complete with infra red sensor, Light
& sensitivity Sensor, Timer with Bye pass facility. Suitable for 400 watts electrical load
SECTION 3.00 FLOOR METAL TRUNKING
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton
70 1-3-10 200 & free from seepage of concrete of screed water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge and Mtr. 421 4.21 425.21
laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D
[7] 50mm x 38mm x 1.6 mm with One Compartments
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton
& free from seepage of concrete of screed water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge and
71 1-3-10 200 laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D Mtr. 610 6.10 616.10
[9] 100mm x 38mm x 1.6 mm with One Compartments
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton
& free from seepage of concrete of screed water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge and
72 1-3-10 200 laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D Mtr. 1,330 13.30 1,343.30
[12] 250mm x 38mm x 1.6mm with Three Compartments
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton
& free from seepage of concrete of screed water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge and
73 1-3-10 300 laying/erecting as per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D Mtr. 1,496 14.96 1,510.96
[13] 300mm x 38mm x 1.6 mm with Three Compartments
SECTION 4.00 SWITCHGEARS & DISTRIBUTION BOARDS
3-10- MINIATURE CIRCUIT BREAKERS.
1.(B) providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to
be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat.III
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box
75 3-10-3. 10 having following capacity Ea. 276 2.76 278.76
(A) 6 to 32 Amp. Cat-III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box
76 3-10-5. 75 having following capacity Cat-III Ea. 723 7.23 730.23
(c)63 Amp. Cat.III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box
77 3-10-5. 30 having following capacity ((QTY FOR MCB OF DB AND MCB OF PANEL)Also consider in general) Cat-III Ea. 590 5.90 595.90
(A) 6-32 Amp Cat.III
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box
78 3-10-5. 75 having following capacity((QTY FOR MCB OF DB AND MCB OF PANEL)Also consider in general) Cat-III Ea. 662 6.62 668.62
(B) 40 Amp Cat.III
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be
79 3-11-5. 5 used) (A) single phase incoming and horizontal single phase outgoing Ea. 877 8.77 885.77
(b) sheet steel double door (IP-43) (ii)6 way
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be
80 3-11-5. 5 used) (A) single phase incoming and horizontal single phase outgoing Ea. 1,141 11.41 1,152.41
(b) sheet steel double door (IP-43) (iii)8 way
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be
81 3-11-5. 5 used) (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) Ea. 2,885 28.85 2,913.85
(b) sheet steel double door (IP-43) (ii)6 way
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be
82 3-11-5. 55 used) (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) Ea. 3,379 33.79 3,412.79
(b) sheet steel double door (IP-43) (iii)8 way
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to
83 3-11-5. 55 be used) suitable for Ea. 4,525 45.25 4,570.25
(B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI)
(b) sheet steel double door (IP-43)
(iv)12 way Cat-III
Providing & erecting approved make thermo plastic MCB/RCCB distribution board having modular Double door with DIN rails, epoxy powder coated
finish metal frame & door assembly with Acrylic/ Plastic door, spring & hinged pins complete with required PVC sleeved 32 / 63A copper Bus strips
without MCB / RCCBs
(e) Two Row 28 Module
Supply installation Testing and commissioning of Surge Protection Device shall be Type-2 for DB LEVEL and IEC 61643-11/2011 T2 and EN 61643-11
Type 2 for internal protection with drill type mounting
EARTH LEAKAGE CIRCUIT BREAKERS.
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA
86 3-12-1. 60 and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate Ea. 1,950 19.50 1,969.50
any electronic component. for following Max. rating erected as directed
(i) 25 Amps.DP Cat-III
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA
and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate
any electronic component. for following Max. rating erected as directed
(ii) 40Amps. DP Cat-III
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA
and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate
any electronic component. for following Max. rating erected as directed
(iii) 63 Amps. DP Cat-III
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Pproviding and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current
rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned
89 3-4-1. 8 copper & complete erected in existing 16 G.M.S. housing. Ea. 6,112 61.12 6,173.12
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current
rating 125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper &
90 3-4-2. 10 complete erected in existing 16 G.M.S. housing. Ea. 7,976 79.76 8,055.76
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal current
rating 200A.with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper &
91 3-4-3. 20 complete erected in existing 16 G.M.S.housing Ea. 16,061 160.61 16,221.61
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. and above at 415 V . having
normal current rating 250A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader
92 3-4-4. 5 tinned copper & complete erected in existing 16 G.M.S. housing. Ea. 20,739 207.39 20,946.39
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 KA and above at 415 V having
Normal current rating 400A. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections, spreader
93 3-4-5. 5 tinned copper & complete erected in existing 16 G.M.S. housing. Ea. 24,979 249.79 25,228.79
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having
normal current rating up to 630A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader
94 3-4-6. 5 tinned copper & complete erected in existing 16 G.M.S. housing Ea. 27,895 278.95 28,173.95
Operational Handle Assembly Complete with spreader links and rotary handle.
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same. ICS=100% of ICU only Cat III
Approved make standard Draw out type 4 Pole Air circuit breaker. Having 50 kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse
voltage=12 kv with following type of relay and accessories.
95 3-5-4. 5 (B) with microprocessor Release with over load, short circuit, earth fault protection and metering display in modular design with LED display and Test Ea. 138,739 1387.39 140,126.39
Trip button facility, CTs and auxiliary contacts, of following current ratings
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same.
(ii) 1000Amp 50 kA Cat III
Approved make standard Draw out type 4 Pole Air circuit breaker. Having 50 kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse
voltage=12 kv with following typ
(B) with microprocessor Release with over load, short circuit, earth fault protection and metering display in modular design with LED display and Test
96 3-5-4. 5 Trip button facility, CTs and auxiliary contacts, of following current ratings. Ea. 188,700 1887.00 190,587.00
Operational Handle Assembly Complete for (ii) 200 / 250 / 320 / 400 / 630 / 800 Amps
The cost inclusive of spreader links and rotary handle. No extra price will be provided for the same.
(iii) 1250Amp 50 kA Cat III
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit
breaker having CT ratio & MCCB rating as following along with shunt trip 220V AC. with all internal connections & complete erected in existing
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit
breaker having CT ratio & MCCB rating as following along with shunt trip 220V AC. with all internal connections & complete erected in existing
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit
breaker having CT ratio & MCCB rating as following along with shunt trip 220V AC. with all internal connections & complete erected in existing
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit
breaker having CT ratio & MCCB rating as following along with shunt trip 220V AC. with all internal connections & complete erected in existing
Providing & erecting additional parts for Air Circuit Breakers as follows:
(B) Auxiliary Contact Block for CN-CS 800 to 2500 & 6 NO + 6 NC
Providing & erecting additional parts for Air Circuit Breakers as follows:
(G) Shunt Release Type EA:24/48 V, 110V, 220V DC
Providing & erecting additional parts for Air Circuit Breakers as follows:
(I) Under Voltage Release Type MV(2) : 240V AC, 415 V AC
Providing & erecting additional parts for Air Circuit Breakers as follows:
(N) CTs for 1250 C / 1600 C for Fixed & Drawout Type ACBs
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not
more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current
105 3-8-1. 5 carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing cubical panel with necessary Rn.Mtr 694 6.94 700.94
(A) Suitable for 100 Amp. capacity
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not
more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current
106 3-8-1. 5 carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing cubical panel with necessary Rn.Mtr 1,027 10.27 1,037.27
(B) Suitable for 200 Amp. Capacity
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not
more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current
106 3-8-1. 5 carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing cubical panel with necessary Rn.Mtr 2,183 21.83 2,204.83
(D) Suitable for 400 Amp. capacity
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not
more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current
107 3-8-1. 5 carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing cubical panel with necessary Rn.Mtr 3,031 30.31 3,061.31
(E) Suitable for 630 Amp. capacity
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not
more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current
108 3-8-1. 10 carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing cubical panel with necessary Rn.Mtr 7,879 78.79 7,957.79
(G) Suitable for 1200 Amp.capacity
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above
protection as per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth
bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket,heavy duty end
109 3-16-1. 10 terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating.(The Sq. Mtr 40,594 405.94 40,999.94
rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall be supplied with following approved manufacturers with following size.
(B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory
(iv) with 1000 mm. depth
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above
protection as per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth
110 3-16-1. 20 bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket,heavy duty end Sq. Mtr 19,196 191.96 19,387.96
terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating.(The
rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall be supplied with following approved manufacturers with following size.
(B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory
(ii) with 550 mm. depth
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above
protection as per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth
111 3-16-1. 10 bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket,heavy duty end Sq. Mtr 14,755 147.55 14,902.55
terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating.(The
rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall be supplied with following approved manufacturers with following size.
(B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory .
(i) with 350mm depth
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if required.
(f) One wire 10.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if required.
(b) One wire 1.50 sq. Mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if required.
(g) One wire 16.00 sq. Mm
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if required.
(c) One wire 2.50 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if required.
(d) One wire 4.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if required.
(e) One wire 6.00 sq. mm
Providing and erecting ,Fabricating the box type items made from M.S. Sheet with A.I. supports, wings, doors, handles other hardware materials as per
118 3-16-4-B 50 requirement design with finishing by three tank powder coating processed inside and outside painted, erected as directed including minor civil work. Kg. 179 1.79 180.79
Painting the number and words for inventory Identification on erected fittings / equipment’s or Such accessories as may required with good quality of
119 3-16-7 20 enamelled paint as directed by engineer in charge. Ea. 22 0.22 22.22
(i) up to 20 characters, up to 50 mm height.
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels,
120 3-16-4-A 50 sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer Kg. 77 0.77 77.77
in charge with necessary grouting, cementing, plastering & finishing complete.
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on existing
panel board with all connection, wiring etc .with manufacturers calibration certificate.
Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with
insulating materials connected to the meter
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, complete erected with necessary connections.WITH SWITCH
FOR BMS INTEGRATION FOR ALL FEEDERS OF PANELS. (For R-Y-B & on-off-trip indication)
Providing and erecting multifunctional meter suitable for application of Power monitoring and showing measurement of following Voltage, Frequency,
Apparent energy, Apparent power, Active and reactive energy, Active and reactive power, Average voltage Vavg, Peak demand power PM, QM, SM,
Demand power P, Q, S, Apparent power S, S1, S2, S3, Unbalance current, Power factor and displacement PF (signed, four quadrant), Calculated neutral
124 3-17-5. 20 current, Active, reactive, apparent energy (signed, four quadrant), Active power P, P1, P2, P3, Voltage U21, U32, U13, V1, V2, V3, Phase currents, Average Nos 13,984 139.84 14,123.84
current Iag, Peak demand currents, Reactive power Q, Q1, Q2, Q3, Demand current I1, I2, I3, [Us] rated supply voltage 40...300 V AC 45...65 Hz, 40...300 V
DC, Network frequency 50 Hz, Type of network 3P, Display type 7 segments LED, Display colour Red, Messages display capacity 3 fields of 4 characters,
Display digits 12 digit(s) - 14.2 mm in height
Supplying & fixing Steel Chequered Plate having 7 mm thickness, duly painted with two coats of black Japan colour. (Average Wt 61.1 kg / Sq.Mtr)
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with
memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also
comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as
required with necessary connection erected as directed.
127 6-7-5. 5 Supplying & erecting power contactor for time switch complete erected as per direction Cat III [C] 4 pole 440V 16 Amp. Ea. 849 8.49 857.49
128 6-7-5. 5 Supplying & erecting power contactor for time switch complete erected as per direction Cat III [D] 4 pole 440V 40 Amp. Ea. 2,755 27.55 2,782.55
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
SECTION 5.00 LIGHT FIXTURE AND FAN
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(B) LED Panel Light with provision for Plane front frame with translucent cover fixed to housing complete.IP20
(vi) 36 watts, 24" x 24", Surge- 2KV Cat-lll.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
130 2-15-3 1,200 Luminaire efficacy> 85 lumens/watt , Nos 584 5.84 589.84
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV Cat-lll.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
131 2-15-3 800 Luminaire efficacy> 85 lumens/watt , Nos 751 7.51 758.51
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(iv) 22-24 watts, Surge-2 KV Cat-lll.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V, Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
132 2-15-1 50 Luminaire efficacy> 85 lumens/watt ,LED Nos. 530 5.30 535.30
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Cat-lll
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
133 2-15-3 1,200 Luminaire efficacy> 85 lumens/watt , Nos. 423 4.23 427.23
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV, Surge-2 KV Cat-lll.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V, Power Factor more than 0.9, THD < 15%,
CCT 3000 K to 6500K,
134 2-15-1 100 Luminaire efficacy> 85 lumens/watt ,LED Nos. 370 3.70 373.70
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(A) Tube Light with integral driver
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet cat-iii
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V, Power Factor more than 0.9, THD < 15%,
CCT 3000 K to 6500K,
135 2-15-1 120 Luminaire efficacy> 85 lumens/watt ,LED Nos. 164 1.64 165.64
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(A) Tube Light with integral driver
(i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet cat-iii
FANS & ACCESSORIS.
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3blades with aluminium blades with , canopy & 30 cm. down rod erected with earthing.(Make shall be approved by Engineer in
FAN ACCESSORIES.
137 5-2-1. 350 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation Mtr. 107 1.07 108.07
without leakage and earthing.
138 5-2-2. 350 Supplying & erecting Fan Hook of 10 mm M.S. Round bar grouted in RCC slab with Making the site as original. Ea. 43 0.43 43.43
TABLE FANS, EXHAUST FANS & ACCESSORIES.
Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.
200mm with 1350RPM Cat.II
140 5-4-2. 5 Supplying and erecting approved make oscillating type bracket fan A.C. 23OV. 50cy/s 400/450 mm sweep wall mounted with height adjustment and Ea. 2,509 25.09 2,534.09
rotary tilting device complete with guard, flexible Core plug top complete erected with lead wires as directed. Cat.II
SECTION 6.00 EARTHING AND LIGHTINING PROTECTION
141 3-14-2 1,500 Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using Kg. 77 0.77 77.77
142 3-14-5 300 Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.Using for DB earthing wire 8 to 16 SWG. Kg. 77 0.77 77.77
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Supplying & erecting funnel type earthing having earth plate of following size burred in specifically prepared earth pit 3 mtr. below ground with
kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I.
Cover complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate
143 3-14-12 8 and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth Ea. 7,797 77.97 7,874.97
tester confirming to IS (As per drawing) with following specification
(C) with 60 x 60x 0.315 cms. Copper earth Plate
SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 micron copper bonding & 1 bag of Carbon fill Based
environment friendly backfill tested as per IEC 62561-7 in NABL accredited Laboratory and suitable stainless Steel double sided clamp. Eco Friendly rust
144 10-5-5. 50 proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height). Ea. 5,933 59.33 5,992.33
SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000-4000 mm long. Air Termination Base tested for conditioning, Ageing
145 10-5-1 15 Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 Ea. 9323 93.23 9,416.23
2017 protocol with MAST 34mm dia 3000 mm long- Cold Galvanized
SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC 62561- 2 conducted in the Govt. accredited thirty party
laboratory to meet the requirement of IS/IEC 62305 with Required Accessories - Aluminium Holding clamp at every 1 mtr distance, Aluminium/SS cross
146 10-5-2 300 splicer at every crossing of Alu. conductor, Expansion piece with connectors at every 20 mtr distance, Aluminium straight Splicer to connect conductors. Mtr. 297 2.97 299.97
All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test:
kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to meet the
requirements of IS/IEC
Supply Installation Testing and Commissioning of Supply of 8 mm Aluminium Round Conductor complete as
specified in drawing & meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC62305). Roof conductor holder for
parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature
resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Cross universal connector: For T and cross connection, to route
147 10-5-3 600 vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts Mtr. 721 7.21 728.21
M8*25 with M8 hexagonal nuts .Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in
drawing and directed by Engineer.Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also
tested as per IEC 62561-6.
with following type accessories.
(OEM shall conduct survey of the premises and submit feasibility report prior to supply of materials and installation).
SECTION 7.00 UPS SYSTEM
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier &
Inverter & sealed maintenance free SMF batteries. The charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz
148 8-15-5 2 Ac with 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection equipment. The system housed in CRC Nos 268,306 2683.06 270,989.06
sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
(I) 10 KVA 3 - phase with 1Hr Backup
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier &
Inverter & sealed maintenance free SMF batteries. The charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz
149 8-15-5 4 Ac with 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection equipment. The system housed in CRC Nos 393,391 3933.91 397,324.91
sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
(J) 20 KVA 3 - phase with 1Hr Backup
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier &
Inverter & sealed maintenance free SMF batteries. The charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz
150 8-15-5 3 Ac with 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection equipment. The system housed in CRC Nos 575,425 5754.25 581,179.25
sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
(K) 30 KVA 3 - phase with 1Hr Backup
SECTION 8.00 WATER COOLER
Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of
151 8-13-2. 5 the water should drop by 15˚C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, Ea. 55,340 553.40 55,893.40
water tank surrounded by evaporating, coil, thermostats, relay etc.complete with necessary inlet & outlet connection. The body of water cooler will be
made from Stainless Steel.
SECTION 9.00 HT CABLE
152 NSR 100 Providing and erecting ISI Marked 3core 300 Sq.mm XLPE insulated 11 KV armoured cable Aluminium conductor to be laid on wall with clamps or in Mtr. 3,000 30.00 3,030.00
provided cable trench / pipe approved manner as directed.
Supply, installation,testing and commissioning of outdoor (IP-65) 1 WAY, 11KV PANEL as per SLD, Specification, Technical Data sheet,IS & make list.
Supply, installaton, testing & commissioning of 11KV breaker panel as per Specifications, Technical Data sheet, Standards & Make list with metering
unit, comprissing of following:
VCB : 1 Nos. (1No. of I/C), 11KV, 3 phase, 50Hz, 1 No. 630A, 21 KA, VCB, motor operated spring charge mechanism. Breaker shall be horizontal draw out
type. Basic insulation level 28kV power frequency withstand 75kVp lightening impulse, with closing & tripping coil, auxiliary contact - 4NO + 4NC,
mechanical ON / OFF indicator & push button, with mechanical antipumping feature & power pack unit.
Main busbar - 11Kv, 3phase, 3W, 50Hz, 630A, Al busbar, 21KA for 3 second.
Incomer side CT - 1-phase, epoxy cast resin type, CT ratio of 300/5+5A, BIL:28RMS/75kVp. ( panel builder check CT ration as per standard requirement )
153 NSR 1 core-1: 15VA, CL-1.0, for metering & core-2: 15VA, CL-5P10 for protection. Nos 550,000 5500.00 555,500.00
Outgoing Side CT - 1-phase, epoxy cast resin type, CT ratio of 150/5+5A, BIL:28RMS/75kVp. ( panel builder check CT ratio as per standard requirement )
core-1: 15VA, CL-1.0, for metering & core-2: 15VA, CL-5P10 for protection.
Digital Multifunction Meter, CL-1.0
Indication Lamps & protection relays - R,Y,B phase Indications, VCB On and OFF, breaker control switch, Autotrip/trip circuit healthy/ test/ service,
spring charge, motor spring charge, Annunciator, Emergency stop push button, space heater, thermostate and panel illumination, 12 window
annunciator, door limit switch for test and service position, BMS compatible.
Protection & Measuring CT ratio change as per transformer sizing shall be calculated by ht panel vendor before finalization.
Protection relays as 50, 50N, 51, 51N, 94 , 86, 27 , 59, 64R. Panel shall be as per SLD and technical specifications.
Supply, Installation, testing and commissioning Heat Shrinkable type high tension cable end box Indoor type suitable IS: 13573-1992. for 11 KV
Sq.mm 3core H.T. cable complete with gland bushing and jointing material.
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
SECTION 10.00 TRANSFORMER & SUBSTATION EQUIPEMENT
SITC of 11KV OUTDOOR COMPACT SUB-STATION WITH OIL TYPE TRANSFORMER
A. HT SWITCHGEAR
11 KV HT RING MAIN as per following specification,
1 WAY NON-EXTENSIBLE 11 KV , 21 KA FOR 3 Sec MOTORISED OPERATED 3 NOS 630A VCB SF6 ENCLOSED MOTORISED BREAKER 24V DC FROM
BATTERY / BATTERY CHARGER, SELF POWERED 3 O/C +1E/F RELAY - 2 NOS, CT RATIO -100-50/1-1A, CL -5P10, 2.5VA, CL 1.0, 2.5VA, GAS PRESSURE
INDICATOR, LOCAL REMOTE SWITCH - 3 NOS, BATTERY WITH BATTERY CHARGER (230VAC TO 24V DC) - 1 NO, FEEDER PROTECTION RELAY
(50,51,50N,51N,64R,27,59) - 1 NOS, MASTER TRIP RELAY - 1 NOS
DIGITAL TRAFO CARD FOR BUCHHOLZ, WTI, OTI TRIP - 1 NOS, MFM WITH RS 485 PORT - 3NOS ,DIGITAL VOLTMETER - 1 NO,VOLTAGE TRANSFORMER,
11000/RT3/110/RT3/110/RT3, CORE 1 : CL 1.0, 200VA, CORE 2 : CL 3P, 100VA QTY : 3 NOS, Control Cabelling from Transformer to NCT & vice versa shall
be in scope of CSS vendor.
B OIL TYPE TRANSFORMER
SITC of approved make oil immersed 1000 kva ONAN cooled, double wound, core type indoor copper wound 11KV/ 433V step down transformer of
following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil not exceeding
Deg.C.at maximum ambient temp. of 50 Deg. C. complete with necessary radiator first filling of new transformer oil & standard fitting as below
complying with IS 1180( Part 1 ):2014 standards with energy efficiency level 2 Off load tap changing range steps +2.5% to -5% on H.V for variation
should be provided. The H.V. shall be connected Delta & Secondary with star connection. The transformer should have cable-end boxes on H.T. side
suitable for up to 3 core 300 sq.mm. XLPE cable & on L.T. side suitable for bus duct or cables as per requirement complete with test certificates from
1. Oil conservator with filling Hole & Cap - One No. ,Thermometer pocket with 6" dial type thermometer switch alarm & trip contacts- Two nos.,
Silica-gel breather with charge- One No. 4. Plain oil level gauge - One No., Drain / Sampling / Filter valve- One No., Top Filter Valve - One No.,
Explosion vent with Diaphragm - One No., Rating & Diagram plate - One No., Additional neutral bushing for earthing - One No., Bi directional
Roller - Four Nos.
C. LV PANEL Earthing
1600AMPS terminals - BUSBAR
ALUMINIUM Two Nos.50KA
Lifting lugs -FOR
(100% TwoPHASES
release plug. - One
NEUTRAL) No., Double
- CURRENT floatOF
DENSITY buchholz relay with
ALUMINIUM AlarmLT
0.8 A/sq.mm. and trip
shall be made up of 1.5/2mm thick CRCA sheet. Interconnection between Transformer and LT Switchgear shall be using Aluminium busbars.
INCOMER CUM OUTGOING FROM TRANSFORMER
1 Nos. 1600 Amps 433V 4P 50Hz 50KA EDO Type Air Circuit Breaker (ACB) with Microprocessor based release for Overload , Shortcircuit and Earth Fault
protection, RYB, ON/OFF Trip Indication with MCB protection , MFM class 1,relay,under voltage protection relay, over protection relay,high speed
tripping relay/master trip relay, over current and Earth Fault (IDMT+Inst.) relay protection as per standard specifications, Protective CT shall be 2000/5A
15VA 5P10,REF CT shall be 3200/5A 15VA Class PS, CT – 1600/5A, CL - 0.5, Burden - 15VA for Metering., PT -433V/√3/110V/√3, CL - 0.5, Burden -
100VA., , BMS Compitible Outgoing Cable Terminaiton arrangment suitbale for 6 # 3.5C X400 SQ MM AL XLPE CABLE.
D. OUTDOOR ENCLOSURE
Outdoor type enclosure having construction of Galvanised Sheet Steel having 2mm thickness for Load bearing member and 1.5mm thickness for Non
Load bearing members with minimum 4mm thick ISMC Channel base frame in corrugated type wall design for better heat dissipation and providing
robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for
Transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint ( colour RAL 7032 ). Each compartment shall be
provided with the door and pad locking arrangement. Doors of transformer compartment are fitted with Arc reflectors from the inside for providing
better safety. The Compartment illumination lamp with door operated switch shall be provided for each compartment.BMS compatible.
E. INTERCONNECTION AND EARTHING
Interconnection Between HT switchgear & Transformer using 1Cx3Rx300 Sq.mm XLPE Aluminum Single core cable & Interconnection between
Transformer & LT switchgear using Aluminium Busbars. Internal earthing connections by 50 x 6mm GI strips.
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Supplying, Testing, Commissioning & unloading at site, shifting to the erection site assembling, leveling, grouting, installing, field testing and
commissioning of 350 KVA Stabilizer.As per Specification, Technical Data sheet,IS , comprissing of following:.
Input supply system:-3Phase,4 wire, 50 Hz +/- 2 % AC for unbalance load
Input voltage range:360 TO 480 V, Supply Frequency:-50 Hz +/- 2%,,Output Voltage:-415 +/- 2%
Type of duty:-Continuous heavy duty with constant output voltage to suit voltage sensitive equipment.
Load:-Suitable for 3 Phase Unbalanced Load (100% Unbalanced Load) with Individual Phase Voltage Correction
Unit efficiency:-More than 95% at rated output.
Servo Motor Drive:-Triac based drive for AC Step Synchronous motor.
Type of Servo Control:-Micro Controller based True RMS sensing and correction.
Electronic overload Cutoff:-CT based Electronic cut off circuit with graded time delay set @ 110% of rated full Load current.
Controls:-Through synchronous servo motor capable of producing high torque with low inertia & capable to withstand lock rotor test as per clause 10-
17 in IS:9815-1981. ,Correction rate:-8-12 V/sec. P to P .,Installation TYPE:-Outdoor,Response Time:-10ms
Type of Oil:-Transformer Oil, Grade 40 KVA, Confirming to IS335.,Type of cooling:-Oil cooling ,Class of insulation:-Class – A/B
Ambient/operating temperature range:-0 - 55 degree.,Relative humidity:-95% non-dripping.
Mode of operation:-Auto/Manual mode with selector switch and manual set of push button shall be provided along with Lower/Rise
selector switch provides on front panel along with bypass switch.
Protection:-Under/Over voltage and Single phase preventation shall be provided.
Additional Protection:-Over load/Short circuit/Manual Bypass/Input MCCB.
Metering:-Seven Segment Display.
Harmonics controls:-Suitable RC Network/MOVE snubber ckt. for AC Synchronous Motor.
Documentation:-Detailed operation manual should be provided which contain operation maintenance and troubleshooting guide and complete set of
wiring drawings. Cabinet/Enclosure:-CRCA sheet steel fabricated free standing floor mounting type dust & vermin proof closed cabinet. Paint:-The
Providingshould be first
and fixing painted
printed with red chart
instruction oxide both
and then two coats
in English of anticorrosive
and Gujarati and dulyair dried enameled
framed with front paint applied
glasses, on primer
for treatment ofand putty
person finish. Dimmer:-
Electric shock with minimum 50" diagonally size.
157 10-2-2. 2 Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. Ea. 212 2.12 214.12
158 10-2-3 50 Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (b)4mm Sq.Mtr 1,017 10.17 1,027.17
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use
159 10-2-4. 5 bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard Ea. 297 2.97 299.97
Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and
brackets confirming to IS 2171 1985 and complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts grouted in wall
complete.. [A] For 5 Kg Capacity
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete. [A] For 4.5 Kg Capacity
SECTION 11.00 LIAISONING WORK
POWER CONNECTION & STATUTORY APPROVALS
(LIAISONING WORK FOR TORRENT POWER/GEB FOR TRANSFORMER - 1 NOS. 500 KVA CSS & 1 NOS. DG SETS - 500 KVA)
162 JOB 1 Charges for doing liasioning work for taking power for the premises obtaining the necessary clearances from the Electrical inspector / competent job 100,000 1000.00 101,000.00
Authorities for the total Electrical installation, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required
by these authorities shall be prepared and furnished by the contractor. Any modification/rectification as required by these authorities shall be carried
out by the Contractor.
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
SECTION 12.00 DG SET
Supplying and erecting, commissioning and testing of Diesel Generating set confirming to IS: 4722:1968 & BS:5514 having continuous rating, 3 phase,
415 volts, 50 cycles A.C. supply comprising of a totally enclosed air/water cooled diesel engine with multi-cylinders developing suitable BHP not less
than following capacity at 1500 RPM with 10% overload for one hour in 24 hours with standard accessories like fly wheel, lubricating oil cooler, "A"
class governor, heavy duty fuel wheel and lubricating oil filter, oil bath air filler, lubricating oil pressure gauge, end exhaust manifold, standard set of
tools with adjustable spanners, screw drivers, cylinder head to cover, joint cylinder head to exhaust, element lube oil filter, 12 / 24 volts electric starting
equipment complete with standard heavy duty battery, dynamo, cut-outs, ammeter, necessary wiring, pressure gauge, starter etc and heavy duty
Residential type exhaust silencer (With DEF System) and vertical hot air duct both
logged with asbestos rope, save oil trays, exhaust piping of required length, standard wall/floor mounted fuel with level indicator and piping and drip
proof alternator, self excited, self regulated, screen protected, with excitation system, capable of delivering the rated system output at 415 volts,
phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722- 1968 with voltage regulation +/- 5% of rated voltage from no load to full
load. Both the engine and alternator fitted on a common fabricated steel base plate with antivibration mounting engine and alternator both
connected to each other by flexible flange coupling and with floor/wall mounted control panel box comprising of voltmeter ammeter, selector
switches, ACB / MCCB / MCB of adequate capacity,
indicator lamps duly wired with HRC fuses. The alternator & control panel shall be connected with provided suitable capacity armoured cable and
complete with Acoustic enclosure (canopy) made out of 16 SWG CRCA Sheet, sound absorbing material Rockwool of 64 density & 100 mm thick
conforming to IS:8183 / PU Foam of 40 Density - at least 40 mm. The resin bonded rockwool covered from inside the canopy by perforated sheet with
3/4 mm holes, sound level not more than 75 dB at a distance of 1 mtr, as per PVCT norms.DG set should have in built fuel tank capacity of minimum
hrs of continous running capacity on full load . Erection, commissioning and satisfactory testing as per requirement with first filling of fuel (minimum up
to the 80% of fuel tank capacity), oil, etc. with guarantee / Warrantee of complete system for Two years. & with obtaining all necessary certificate from
Electrical Inspector. The Capacity and Ratings of DG sets are as below. (As per new CPCB4+ Emission norms Engine With - Turbo Charger, EGR (Exhaust
Gas Recirculation), CRS (Common Rail Fuel System), DOC (Diesel Oxidation Catalyst), SCR (Selective Catalytic Reduction), Integrated wiring harness
Providing &toerecting
ECU .) approved make AMF control panel suitable for following size of 3 phase, 415 V., 50 cycles, A.C. diesel generating set complete of
scope as detailed below:
1) Power module: A pair of electromechanically interlocked contactors (for mains & generator) Overload relay for generator contactor Neutral
contactor for mains and generator Power socket for connections.
2) Control and metering module: Line voltage monitor. Generator voltage monitor Ammeter 3 items attempt start facility. Air circuit
breakers/MCB/MCCB of suitable rating for auto/manual operation. Auto/manual switch. Emergency stop push buttons. Manual start push button.
frequency meter. Engine hour meter. Two earthing studs.
3) Protection module: The engine shutdown in the unlikely event of Low lube oil pressure High cylinder head temperature. V belt failure.
4) Indicators with alarm Load on generator.
5) Indicators Load on mains Engine fails to start . Emergency stop battery charger.
The AMF Panel of following capacity
(G) AMF Control Panel for 500 KVA 3 phase DG Set
providng and erecting Approved make. energy meter 3 phase 4 wire unbalanced load 500 V.50A / 100A complete erected as directed with necessary
earth wire. Cat. III
166 3-15-7 2.00 providng and erecting Suitable set of CTS for 100A Energy Meter Nos. 2,085 20.85 2,105.85
Providing & erecting approved make ATS panel suitable for following size of 3 phase, 415 V., 50 cycles, A.C. diesel generating set complete of scope as
detailed below:
167 10-4-3. 2.00 1) Power module: Motorised Changeover switch with ATS controller, Auxiliary contactor with NO & NC contacts with Automatic Battery Charger, Nos. 177,967 1779.67 179,746.67
indicating lamps for Generator ON, Mains ON, Load and suitable control terminals and power terminals with neutral earthing studs.
(H) ATS Panel for 320 KVA/ 380 / 400 /500 KVA3 ph DG Set
Supplying & erecting approved make Four Pole 415V Motorised Automatic transfer switch including controller with UV/OV, phase sequence, single
168 3-18-1. 2.00 phasing and frequency protection interior for panel mounting with operating mechanism A.C.23A duty confirming to IS for Nos. 136,923 1369.23 138,292.23
(K) 1000 A Cat. III
Qnty may Rate SOR Rate With 1% Estimated
Number SOR NO Item Description Unit 1% Lc.
be more or In Figure L.C. Amount
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps,
vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly
painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.
168 8-10-11. 60.00 Note:- The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as Mtr. 5,123 51.23 5,174.23
per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and
(C.) 200mm dia.
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels,
165 3-16-4-A 300 sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer Kg. 77 0.77 77.77
in charge with necessary grouting, cementing, plastering & finishing complete.
SECTION 10.00 LT PANEL TTA-IEC
Supply, installation, assembling, connection, testing and commissioning of TTA (IEC-61439) LT Indoor multi panel board WITH PLC LOGIC PANEL as per
specification and approved make list. refer single line diagram NON SOR MAIN LT PANEL FOR RATING OF OF BREAKER & TYPE OF BREAKER & PLC
(WITH HMI SCREEN) LOGIC TABLE.
>Incomer:-2 nos 1600 Amp 4P EDO ACB 65 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible
ICU=ICW=ICS=100%, CT connetction,Spring Charge Motor Health,50 Trip history & Event Record with date & time stamping also with current &
voltage percentage THD. WITH 64 R - Resricted Earth Fault Relay, 86- Tripping Relay - CLR, 50 N- Instantaneous Over Current Relay,51- IDMT Over
-2 nos 1000 Amp 4P EDO ACB 65 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible
ICU=ICW=ICS=100%, CT connetction,Spring Charge Motor Health,50 Trip history & Event Record with date & time stamping also with current &
voltage percentage THD. WITH 64 R - Resricted Earth Fault Relay, 86- Tripping Relay - CLR, 50 N- Instantaneous Over Current Relay,51- IDMT Over
>BUS COUPLER:-3 nos 1600 Amp 4P EDO ACB 65 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible
ICU=ICW=ICS=100%, CT connetction,Spring Charge Motor Health,50 Trip history & Event Record with date & time stamping also with current &
voltage percentage THD.
>Bus Bar:-2000 Amp 4P 65 ka al. busbar.
>FOR PLC LOGIC TABLE REFER SINGLE LINE DIAGRAM. Note that PLC LOGIC TABLE shall be change as per detail design.
>Outgoing:-2 nos 1250 Amp 4P EDO ACB 65 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible
ICU=ICW=ICS=100%, CT connetction,Spring Charge Motor Health,50 Trip history & Event Record with date & time stamping also with current &
166 NSR 1.00 voltage percentage THD. Ea. 5,500,000 55000.00 5555000.00
4 nos 1000 Amp 4P EDO ACB 65 KA with MP based release having O/L ,S/C, E/F Protection, Under Voltage Communicable Compatible
ICU=ICW=ICS=100%, CT connetction,Spring Charge Motor Health,50 Trip history & Event Record with date & time stamping also with current &
nos 630A,4P,50 THD. WITH MICROPROCESSOR BASED RELEASE (O/L,S/C,E/F PROTE.) with CT and MFM &ON ,OFF ,TRIP & RYB indication lamps,
Potential free contacts for BMS compatibilty.
2 nos 400A,4P,50 KA,MCCB WITH MICROPROCESSOR BASED RELEASE (O/L,S/C,E/F PROTE.) with CT and MFM &ON ,OFF ,TRIP & RYB indication lamps,
Potential free contacts for BMS compatibilty.
2 nos 250A,4P,50 KA,MCCB WITH MICROPROCESSOR BASED RELEASE (O/L,S/C,E/F PROTE.) with CT and MFM &ON ,OFF ,TRIP & RYB indication lamps,
Potential free contacts for BMS compatibilty.
2 nos 125A,4P,50 KA,MCCB WITH MICROPROCESSOR BASED RELEASE (O/L,S/C,E/F PROTE.) with CT and MFM &ON ,OFF ,TRIP & RYB indication lamps,
Potential free contacts for BMS compatibilty.
>ALL ACB/MCCB WITH Auto Manual rotary handle and TNC Switch Emergency Switch and Trip Push Button Earthing,and Fabrication.as per single line
The rate shall include freight, storage, inspection chanrges and conplete installation and required assecories like floor stand and fabrication to mount
the panel. with voltage Surge Protection Device 70 KA,2KV FP VSP Imax=70 KA-2.0 kV(Protection Level )Type -1,2, 230/400 V AC ,high Protection VSP
,protcts appliance against transient micro surges of 8/20 micro second.
As per drawing and design supplied by architect and instruction given by authority and E.I.C.For ACB breaker For communication on ethernet
platform,network protocall such as moodbus/ethernet/profinet shall be actable ,Convertor shall be actable to convert protocall to match with the scada
sysytem & necessary hard ware inside the panel it self.
The protocall for the scada system shall be convene during detail design.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ FOR GCRI CANCER HOSPITAL_13.03.2026.pdf
Final Bid Documents CIVIL WORK.pdf
TECHNICAL SPECIFICATIONS_13.03.2026_compressed.pdf
CIVIL WORKS TENDER NOTICE.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .