| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC H NO 107 A RAJENDRA NAGAR DIGARI KALAN JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L1 | Accepted-AOC Accepting being L1 | |
| 2 | L2₹37.9 L+₹46,588.30 (1.25%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹44.0 L+₹6.6 L (17.7%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹46.3 L+₹8.9 L (23.8%)Rejected-Finance OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical WLR NOT OK |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
23 Nov 2023, 6:00 pmClosed
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
SPL REPAIR TO BLDG NO P - 1607 (KONARK OFFICERS MESS) TO INCLUDING ROOF TREATMENT AND ALLIED WORKS AT AGE B/R-II AREA UNDER GE ARMY NO. 1 JODHPUR.
2023_MES_624912_1
GE/JODH (A) NO 1- OF 2023-24 (9207/E8)
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY NO. 1
₹95,000
Yes
24 Jan 2024
25 Oct 2023
1 Dec 2023
25 Oct 2023
23 Nov 2023
9 Nov 2023
Amount
S&F in replacement 500 ltrs capacity rotational moulded polythene water storage tanks white colour, three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms, including dismantling of old U/S PVC/RCC water tank & removing to store or outside MD land or credit to contractor, complete all as specified and as directed.
All as per item No. 1.00 here-in-above, but tank capacity is 1000 ltrs
Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and directed.
All as per item No 3.00 here-in-above, but size of pipe 20 mm bore.
All as per item No 3.00 here-in-above, but size of pipe 25 mm bore.
S&F of water GI tubing medium grade, galvanized, with all fittings fixed to wall, ceilings or laid n floors, including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc., complete all as specified and as directed. (a) 15 mm bore,
All as per item No 6.00 here-in-above, but size of pipe 20 mm bore.
All as per item No 6.00 here-in-above, but size of pipe 25 mm bore.
Demolition of cement concrete as removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster, padding,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
M&L for plain cement concrete 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregate), as in roof padding over roof for making good depression / undulation to make the existing as filling in depression of roof slab, complete all as specified & directed.
M&L for neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions over the RCC roof slab for laying of water proofing treatment including providing the following as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 100mm micron HMHDPE, outer film 20 micron each, thickness 3.00mm having weight not less than 3.00 Kg/Sqm, mineral gravel finish on top, using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen conforming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FIFTH COURSE : 40 mm thick plain cement concrete 1:2:4 (using 20 mm stone crushed aggregate) as in roof padding, well compacted with V -shaped groove 6 mm wide and 10 mm depth filled with mastic bitumen of (1:1) of proportion complete,size of PCC panel with grooves shall not be exceed 1.50 Sqm including WPC as per manufacturer instruction. NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item.
M&L for rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, bracket for sunshade etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars ,barred iron doors; ladders ;framed balusters walk ways railings framed work of water tanks and similar work confirming to Fe-290Gde E-165 complete all as specified and as directed.
Taking down carefully cement conc /spalled out concrete from RCC roof projections, cilinigs ,sunsheds, beams, etc upto cover depth by chipping out lightly including necessary scafolding etc., and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
M&L for cleaning the existing reinf of slabs , chajjas etc & applying a coat of SIKA RUSTOFF 11 to remove the loose rust particles etc & throughly cleaning the surface.,complete all as specified and as directed.
M&L for applying a coat of bond coat made with cement slurry (1 part cement to 1.5 -2 parts water) mixed with admixture LATEX POWER mixed @5 Kg per 50 kg of cement & applying to the conc surfaces @ 200 gm/sqm to obtain tack.,complete all as specified and as directed.
M&L for 15 -20 mm thick rendering in CM (1:1:2) using1 part of cement 1 part 2-3 mm screenings of stone agg & 2 parts coarse sand over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPER admixture @ 100 gm /50kg of cement & finishing the surface even & rough to receive final rendering coat. ,complete all as specified and as directed.
M&L for 10-15 mm thick rendering in CM 1:3 over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPER admixture @ 100 gm /50kg of cement & finishing the surface even & smooth complete all as directed at site ,complete all as specified and as directed.
S&F GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/fascias etc,complete all as specified and as directed.
Demolition of reinforced cement concrete of any description for Chajja , railing, ladder , facia , manhole cover, colums , self slab of type, other places etc complete all as specified and directed.
M&L for RCC M-25 (20 mm graded aggregate) in chajjas including necessary form work and scaffolding complete all as directed and specified
M&L for TMT bar HYSD steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Taking down cement plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement, complete all as specified and as directed.
M&L 15 mm thick rendering in cement mortar 1:4 on fair faces of stone or brick work or concrete surfaces mixed with water proofing compound as per manufacturer instructions and finished the surfaces even and smooth with out using extra cement complete all as specified and as directed. Note :- WPC will be measured and paid seperately.
M&L 10 mm thick rendering in cement mortar 1:4 on fair faces of stone on concrete surfaces of ceiling mixed with water proofing compound as per manufacturer instructions and finished the surfaces even and smooth with out using extra cement complete all as specified and as directed. Note :- WPC will be measured and paid seperately.
Complete removal of existing treatment from walls /ceiling, complete all as per specified & directed.
M&L for preparation of new plastered or unplastered surfaces of wall surfaces and applying with 2 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete all as specified and as directed.
M&L for Preparation new plastered or unplastered surfaces or old decorated surface of wall and applying two coats of oil bound distemper on walls/ceiling complete all as specified and as directed.
M&L for preparation of old decorated wall surfaces plastered or unplastered, by brooming down or steel wire brushing, scrapping down moulds, moss and efflorescent salts and trading oil & greasy spots, including cornices etc and applying one coat of white wash on wall, complete all as specified and directed.
All as per item No. 29.00 here-in-above, but as on ceiling surfaces
M&L for preparing new plastered or unplastered surfaces or old decorated surface of wall and applying two coats of exterior weather coat over & including one coat of primer on walls complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete
M&L for Granite slab 18 to 20mm thick machine cut, factory polished, Jet Black colour, as in cooking plateform/oval type WHB Counter & similar, bedded and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the shade of granite stone over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles (premium quality) of size 6 to 7 mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed.
All as per item No. 35.00 here-in-above, but size area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm
M&L for dark shade/double charged vitrified ceramic tiles, 10 mm thick (square/ rectagular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm, (size & shape, shade and pattern as approved by GE), as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles, over & including M&L 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
All as per item No. 37.00 here-in-above, but as in skirting with 10 mm thick backing coat in cement motar CM 1:3.
M&L for machine cut kota stone slab 20 to 25mm thick in floor laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20mm thick screed bed in CM 1:4 including dismantling of stone slabs of any description complete all as specified and as directed.
All as per item No. 39.00 here-in-above, but as in skirting with 10 mm thick backing coat in cement motar CM 1:3.
M&L Plain cement concrete 1:3:6 type C-2 by using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed .
M&L Sand stone slabs, 5 cm thick, Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and as directed.
M&L for joint free glazed colour ceramic tiles (premium quality) of size 250X450X6-7mm / 300X450X6-7 mm, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including M&L 10mm thick backing coat in CM (1:3) complete all as specified and directed.
S&F in replacement bib cock (Brand-I) with wall flange, chromium plated brass, fancy type, 15mm dia complete all as specified and as directed.
S&F in replacement angular stop cock (Brand-I) with wall flange, chromium plated brass, fancy type, 15mm dia complete all as specified and as directed.
S&F in replacement Hand Shower (Health Faucet) (Brand-I) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) , 15mm dia complete all as specified and as directed.
S&F in replacement two way angle cock (Brand-I) with wall flange, chromium plated brass, fancy type 15mm dia complete all as specified and as directed.
S&F in replacement pillar cock (Brand-I) with wall flange, chromium plated brass, fancy type, single lever, long body with 180 mm extension body fixed spout without popup waste system with 600 mm long braided hoses, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe 15mm dia complete all as specified and as directed.
S & F table top vitreous china ware wash hand basin, approved size (shade and size & model approved by GE) including 32 mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe,PVC connection15mm size with PTMT nuts of length 450mm long, complete all as specified and as directed.
S&F in replacement Rimless Single Piece EWC (Brand-I) Size: 395x710x730 mm, with UF Soft Close Seat Cover, Hinges, Dual Flush Cistern Fitting, Fixing Accessories and Accessories Set,etc complete, S Trap- 300 mm, complete all as specified and as directed.
S&F in repair corner sheet glass of 6mm thick superior quality, 300mm size,as in shelf, CP tubular framing fancy type, triangular in shape and one side circular complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D Type, 600 mm long between flanges including brackets complete all as specified and as directed.
S&F 12mm thick plain gypsum board false ceiling with GI frame work including all necessary drilling, cutting to fix electical items with any design or step design, two coats putty & two coats of oil bound distemper, complete all as specified and directed with followings:-(a) GI sheet channel 30x25x20mm of 24 Gauge fixed with rawl plug and screws 450mm centre to centre along with perimeter of walls. (b) GI sheet channel made to shape 50x40x40mm of 24 guage placed @ 600mm centre to centre from perimeter of wall except long wall (in one span) (d) GI sheet 25mm wide & 20mm gauge suspenders fixed with steel fasteners to roof, ceiling @ 1200 mm centre to centre incl plugging in RCC slab and 75-100 mm wide POP moulded cornices, moulding fixed on ceiling/wall joints complete all as specified and directed.
S&F in replacement 75mm dia PVC (SWR) pipes single socketed, in any length with or without ears with cement joints, laid in trenches or in floors and including old u/s demolation drain/PVC/CI pipe ,complete all as specified and as directed
S&F in replacement 110mm bore PVC (SWR) pipes single socketed, in any length with or without ears with cement joints, laid in trenches or in floors and including old u/s demolation drain/PVC/CI pipe ,complete all as specified and as directed
S&F for 75mm PVC (SWR) bends (any radius), diminishing pieces or tapers (larger bore measured) ,complete all as specified and as directed
S&F in replacement 110mm bore PVC (SWR) bends (any radius), diminishing pieces or tapers (larger bore measured) ,complete all as specified and as directed
S&F in replacement decorative type curtain rod stainless steel finish of pipe 22 to 25mm dia with best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end, complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
Taking down of steel windows/vents with all fittings complete carefully & removal away from store, complete all as specified and directed.
M&L for fabrication of powder coated (powder coating min 50 micron) aluminium frame work as in frames for aluminium windows with or without rebate or for sliding windows(two track/three track ), ventilators etc with louvers having suitable mechanism for tilting , U shaped fillets for securing Jallies etc & the likes complete all as per sample kept in GE Office & fixed in position complete all as directed. Note : Glass panes in louvers & stainless steel wire cloth shall be measured & paid for seperately,
M&L for Pre- powder coated (powder coating min 50 micron) aluminium decogrill all as per sample fixed to aluminium framework of windows & ventilators,complete all as specified and as directed.
M&L for Pre powder coated (powder coating min 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified all as directed & specified
M&L for Pre powder coated (powder coating min 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) ,complete all as specified and as directed.
S&F Sheet glass 4.80mm thick, ordinary quality and glazing with oil putty/aluminium with rubber beading in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F in repair Aluminium (Die cast) body Door closer hydraulically regulated, designation No 3 universal type,suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 Kg complete all as specified and as directed.
S&F 12 mm thick toughened glass as in door/window or partition complete including design etching work /sun control film as directed and all necessary stainless steel fittings arrangement like hinges, clips, handle etc, complete all as specified & directed by Engineer-in-charge.
S& F stainless steel body bottom floor spring machine screwed suitable for glass door complete all as specified and as directed
M&L decorative type plaster of paris work of size100 mm x 100 mm, as in cornice or junction of wall and ceiling complete all as specified and directed.
S&F 5-8 mm thick colour PVC insulation sheet in strips & channel feathered at the edges for fixing , Insulated/solid PVC wall lining inclusive of solvent cement and fixing at site including necessary frame work all as directed by Engr in charge.
S & F in repair double action floor spring hydraulically regulated made of aluminium 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty.including fixing of broken tile.
M & L for preparation of old painted wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint of any tint complete all as specified and as directed .
All as per item No. 73.00 here-in-above, but steel surfaces.
M&L FOR Preparation of new or previously untreated steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified and as directed.
Demolition of stone slab including cement mortar bedding and backing coat including removal of debris to out side MD land complete all as specified and as directed.
M&L precast cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in solid block masonry exceeding 10cm width and setting in cement mortar 1:4 complete all as specified and as directed
M&L 75 mm thick PCC 1:4:8 type D-2 using 20mm graded crushed stone aggregate, as in sub base of floor incld. compaction properly & universal and laid to level, complete all as specified and directed.
Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any description, ( colour, design & pattern, & size/ shape, as approved by GE) as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including M&L 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
M&L digital ceramic heavy duty parking tiles 8 to 10 mm thick (square / rectangular) area of each tile exc. 0.08 Sqm but n. exc. 0.16 Sqm as in floors etc, and set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed in CM 1:4 and including demolition complete all as specified and directed.
S&F in repair Prepainted Galvalume aluminium zinc coating GI based corrugated steel Sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws including dismantling of old broken plain or corrugated AC sheets as in roof coverings complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS:1161-1979 Grade St-240 complete all as specified and as directed.
M & L providing 75-80 mm thick pre-cast cement concrete 1:3:6 type C-0 using 12.5 mm graded stone aggregate as in louvers & jallies (measured solid) including all mouldings and including pre-cast frames set in cement mortar 1:6 complete all as specified and as directed.
M & L providing precast concrete Posts 150x150mm size & 75-100 cm height 1:3:6 type C0 using 12.50 mm graded stone aggregate as in RCC jali post setting in mortar 1:6 complete
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
Taking down carefully UNSV submain wiring of any size and all as directed.
M&L for modular point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators, suitable for one light point controlled by one, one way switch, complete all as per specified and directed.
All as per srl item no.89.00 here-in-above but suitable for one socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
All as per srl item no.89.00 here-in-above but suitable for one socket outlet 3 pin 5 amps on the independent board controlled by one no 5 Amp switch.
All as per srl item no.89.00 here-in-above but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
All as per srl item no.89.00 here-in-above but with 4 sq mm FRLS copper wire with 4 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
S&F Modular switch flush type single pole one way 6 Amp ISI Marked, complete all as per specified and directed.
S&F Modular switch flush type single pole one way 16 Amp ISI Marked, complete all as per specified and directed.
S&F Modular socket outlet 2 in 1, 5 pin, 6 Amp, 230 Volts flush type, complete all as per specified and directed.
S&F Modular socket outlet 2 in 1, 6 pin, 5 and 16 amp flush type, 230 Volts ISI Marked, complete all as per specified and directed.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required, complete all as per specified and directed.
S&F moduler Lamp holder, metal cased, bakelite body, 230 volts, complete all as specified and directed.
S&F LED Warm White Bulb 9W complete all as specified and directed by the Engineer-in-Charge.
S&F Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Warm White LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including AC decorative box type with driver, holder including,copper conductor cable of suitable size from ceiling rose complete complete, 4 ft long all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED Warm White light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete and directed by the Engineer-in-Charge. .
Supply and fixing LED Warm White light fitting Aesthetically designed, decorative recess mounted 5 W LED (Round) spot light for low ceiling height applications including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by the Engineer-in-Charge.
S&F MCB, B Curve type, 10 kA, TPN/FP 40 to 100 AMP, TPN with over load and short circuit protection, complete all as directed and directed by the Engineer-in-Charge.
S&F MCB, B Curve type, 10 kA, 40 Amp to 63 Amp, SPN with over load and short circuit protection, complete all as directed and directed by the Engineer-in-Charge.
S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specif and directed by the Engineer-in-Charge.
S&F MCCB, A Frame, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 100 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing as MCB DB TPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.
Supply and fixing as MCB DB TPN (double door) 6 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.
Supply and fixing as MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.
Supply and fixing as MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.
S&F Vertical Distribution Board, double Door, suitable for 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 6 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Note : MCCB & MCB will be measured and paid separately under respective items
M&L for sub main wiring with 2 run of 4 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 15 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two run of 4 Sq.mm. and one run of 4 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for sub main wiring with 2 run of 10 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 25 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two run of 10 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for sub main wiring with 2 run of 16 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 25 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two run of 16 Sq.mm. and one run of 10 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for sub main wiring with 2 run of 25 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 16 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 25 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two run of 25 Sq.mm. and one run of 16 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
Supply and fixing of Modular sheet metal enclosure SPN with a two pin earth plug and socket with metal cladd top including and one MCB,SP 40 amps capacity complete all as specified & directed.
Supply, laying testing in trenches LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 50 sqmm 3.5 core all as diredted by Engr - in - charge. Note : Earth work and brick work measured and paid separately
M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply, laying testing in trenches LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 35 sqmm 3.5 core all as diredted by Engr - in - charge. Note : Earth work and brick work measured and paid separately
Excvation in trenches not more than 1.5 meter wide and in depth in loose soil ll as directed by Engr in Charge
Retuerning and filling of excvated loose soil in treches aall as directed by Engr - in Charge
Removal of surplus loose soil from excavated place and deposting at safe side distance not more than 50 meter from excavated place all as directed
Supply and laying Un reinforced Precast concrete cable cover, flat size 300 mm x 180 mm x 40mm all as and all as specified and direceted by Engr-in-Charge. .
Supply and lay sand for sand cushioning for cable protection in trenches all as directed and specified in SSR Part - 1.Note:. for the purpose of payment punned thickness will be measured and all as specified and direceted by Engr-in-Charge. .
Supply and fix GI tubing medium grade of 40 mm dia for cable protection.
Taking down Indoor Unit and out door unit safely and disconnect copper tube (suction and discharge line ) and relocate new position with proper fastening and drilling suitable hole on wall with proper finish and connect outdoor unit with suitable size of suction and discharge line and refill gas as per existing and connect properly via soldering and MISC work etc including pressureing the complete unit with suitable Gas as per specified and as directed
M&L for checking out of split type AC 1.50/2 TR capacity indoor unit in any position, including necessary servicing i.e. electrical connection wiring, cleaning condensor, blower fan motor, servicing including replacement of micro filter of approved quality and testing for proper functioning of split AC type air conditioner all as directed by Engg.-in-charge. Note: - (1) The rate quoted by the contractor shall be inclusive of maintaining record of machine with capacity, obtain signature of user after satisfactory completion of servcing duly verified by concerned JE/AGE. 2)- Greasing / oiling of blower fan motor including charging of Gas will measured and paid seperately.
M&L for nylon insulation on discharge and suction pipe of split AC in existing location and position, all as directed.
M&L in replacement for copper dischagre tube of size 3/8" duly nylon insulated in existing location and position, all as directed.
M&L in replacement for copper suction tube of size 5/8" duly nylon insulated in existing location and position, all as directed.
Supply only refrigerant gas M-404/444/R22, in existing location and position, all as directed. Note:- Gas to be supplied in cylinder duly sealed by manufacturer/ factory sealed with proper PV's & other docs or specifications
M&L for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 6 Sqmm cross sectional area superior quality complete all as directed by Engr-in-Charge .
NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
RV. Enterprises
JB INFRA
Harsh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .