| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.4 CrAdmitted-Finance | -39.00% | ₹10.4 Cr | L1 | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹75 L
EMD Value
₹1.5 L
Closing Date
18 Feb 2026, 6:00 pmClosed
EE PHED DISTT DIV II JODHPUR
EE PHED DISTT DIV II JODHPUR
ARC FOR EXECUTION OF WORK RELATED TO SUPPLY AND INSTALLATION OF SUB PS MONOBLOCK PS HSC PS PANELS CABLE AND OTHER ALIED WORK UNDER DD II JODHPUR
2026_PHCJO_533632_1
NIT NO 91 YEAR 2025-26
Open Tender
Civil Works
365 days
EE PHED DISTT DIV II JODHPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
EE PHED DISTT DIV II JODHPUR
₹1.5 L
Yes
16 Mar 2026
30 Jan 2026
19 Feb 2026
30 Jan 2026
18 Feb 2026
30 Jan 2026
PHED BSR 2023/2.14/ Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
Up to 2.0 KW
Above 2.0 KW
PHED BSR 2023/2.15 / Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
Up to 5.5 KW (7.5 HP) & head above 120 mtr.
7.5 KW (10 HP) & head up to 120 mtr.
7.5 KW (10 HP) & head above 120 mtr.
9.3 KW (12.5 HP) & head up to 120 mtr.
9.3 KW (12.5 HP) & head above 120 mtr.
11 KW (15 HP) & head up to 120 mtr.
11 KW (15 HP) & head above 120 mtr.
13 KW (17.5 HP) & head up to 120 mtr.
13 KW (17.5 HP) & head above 120 mtr.
15 KW (20 HP) and above, head up to 120 mtr.
15 KW (20 HP) and above, head above 120 mtr.
PHED BSR 2023/2.16/ Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.
PHED BSR 2023/2.17.1/ Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. UP TO 5.00 HP
PHED BSR 2023/2.18/ Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
Above 5 HP and up to 10 HP
Above 10 HP and up to 15 HP
Above 15 HP and up to 20 HP
Above 20 HP and up to 30 HP
PHED BSR 2023/2.19/ Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
3 core 4.0 Sq.mm
3 core 6.0 Sq.mm
3 core 10.0 Sq.mm
3 core 16.0 Sq.mm
PHED BSR 2023/ 2.20/ Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
10.0 Sq.mm, 4 core
16.0 Sq.mm, 4 core
25.0 Sq.mm, 3.5 core
35.0 Sq.mm, 3.5 core
PHED BSR 2023/ 2.21/ x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
PHED BSR 2023/5.1/ Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
Centrifugal Monoblock Pump set (Single Stage)
Centrifugal Monoblock Pump set (Double Stage)
Vacuum Pump set (Monoblock)
PHED BSR 2023/5.2/ Providing, installation, testing and commissioning of Mono block Vacuum pump set with base plate including C.C. foundation / cross channels / RSJ frame and foundation bolts etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge.
0.75 KW (1 HP), single Ph
2.2 KW (3 HP), three Ph
Vacuum Pump set (Coupled)
PHED BSR 2023/5.3/ Providing, installation, testing and commissioning of Vacuum pump set with horizontal foot mounted TEFC squirrel cage motor working on three phase 50 Hz, 415 Volts +/- 10% with base plate including cost of flexible couplings, coupling guard etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge.
PHED BSR 2023/5.4/ Providing, installation, testing and commissioning of Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water immersed, dry air filled, class "F" insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
PHED BSR 2023/ 5.5/ Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
PHED BSR 2023/5.6/ Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
PHED BSR 2023/5.7/ Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.
Discharge 20 to 30 LPS and head 20 to 30 M
Discharge 20 to 30 LPS and head 31 to 40 M
Discharge 20 to 30 LPS and head 41 to 50 M
Discharge 20 to 30 LPS and head 51 to 60 M
Discharge 20 to 30 LPS and head 61 to 70 M
Discharge 20 to 30 LPS and head 71 to 80 M
Discharge 20 to 30 LPS and head 81 to 90 M
Discharge 31 t0 40 LPS and head 20 to 30 M
Discharge 31 t0 40 LPS and head 31 to 40 M
Discharge 31 t0 40 LPS and head 41 to 50 M
Discharge 31 t0 40 LPS and head 51 to 60 M
Discharge 31 t0 40 LPS and head 61 to 70 M
Discharge 31 to 40 LPS and head 71 to 80 M
Discharge 31 to 40 LPS and head 81 to 90 M
Discharge 41 t0 50 LPS and head 20 to 30 M
Discharge 41 t0 50 LPS and head 31 to 40 M
Discharge 41 t0 50 LPS and head 41 to 50 M
Discharge 41 t0 50 LPS and head 51 to 60 M
Discharge 41 t0 50 LPS and head 61 to 70 M
Discharge 41 to 50 LPS and head 71 to 80 M
Discharge 41 to 50 LPS and head 81 to 90 M
Discharge 51 to 60 LPS and head 20 to 30 M
Discharge 51 to 60 LPS and head 31 to 40 M
Discharge 51 to 60 LPS and head 41 to 50 M
Discharge 51 to 60 LPS and head 51 to 60 M
Discharge 51 to 60 LPS and head 61 to 70 M
Discharge 51 to 60 LPS and head 71 to 80 M
Discharge 51 to 60 LPS and head 81 to 90 M
Discharge 61 to 70 LPS and head 20 to 30 M
Discharge 61 to 70 LPS and head 31 to 40 M
Discharge 61 to 70 LPS and head 41 to 50 M
Discharge 61 to 70 LPS and head 51 to 60 M
Discharge 61 to 70 LPS and head 61 to 70 M
Discharge 61 to 70 LPS and head 71 to 80 M
Discharge 61 to 70 LPS and head 81 to 90 M
Discharge 71 to 80 LPS and head 20 to 30 M
Discharge 71 to 80 LPS and head 31 to 40 M
Discharge 71 to 80 LPS and head 41 to 50 M
Discharge 71 to 80 LPS and head 51 to 60 M
Discharge 71 to 80 LPS and head 61 to 70 M
Discharge 71 to 80 LPS and head 71 to 80 M
Discharge 71 to 80 LPS and head 81 to 90 M
Discharge 81 to 90 LPS and head 20 to 30 M
Discharge 81 to 90 LPS and head 31 to 40 M
Discharge 81 to 90 LPS and head 41 to 50 M
Discharge 81 to 90 LPS and head 51 to 60 M
Discharge 81 to 90 LPS and head 61 to 70 M
Discharge 81 to 90 LPS and head 71 to 80 M
Discharge 81 to 90 LPS and head 81 to 90 M
Discharge 91 to 100 LPS and head 20 to 30 M
Discharge 91 to 100 LPS and head 31 to 40 M
Discharge 91 to 100 LPS and head 41 to 50 M
Discharge 91 to 100 LPS and head 51 to 60 M
Discharge 91 to 100 LPS and head 61 to 70 M
Discharge 91 to 100 LPS and head 71 to 80 M
Discharge 91 to 100 LPS and head 81 to 90 M
Discharge 101 to 120 LPS and head 20 to 30 M
Discharge 101 to 120 LPS and head 31 to 40 M
Discharge 101 to 120 LPS and head 41 to 50 M
Discharge 101 to 120 LPS and head 51 to 60 M
Discharge 101 to 120 LPS and head 61 to 70 M
Discharge 101to 120 LPS and head 71 to 80 M
Discharge 101to 120 LPS and head 81 to 90 M
Discharge 121 to 140 LPS and head 20 to 30 M
Discharge 121 to 140 LPS and head 31 to 40 M
Discharge 121 to 140 LPS and head 41 to 50 M
Discharge 121 to 140 LPS and head 51 to 60 M
Discharge 121 to 140 LPS and head 61 to 70 M
Discharge 121 to 140 LPS and head 71 to 80 M
Discharge 121 to 140 LPS and head 81 to 90 M
Discharge 141 to 160 LPS and head 20 to 30 M
Discharge 141 to 160 LPS and head 31 to 40 M
Discharge 141 to 160 LPS and head 41 to 50 M
Discharge 141 to 160 LPS and head 51 to 60 M
Discharge 141 to 160 LPS and head 61 to 70 M
Discharge 141 to 160 LPS and head 71 to 80 M
Discharge 141 to 160 LPS and head 81 to 90 M
Discharge 161 to 180 LPS and head 20 to 30 M
Discharge 161 to 180 LPS and head 31 to 40 M
Discharge 161 to 180 LPS and head 41 to 50 M
Discharge 161 to 180 LPS and head 51 to 60 M
Discharge 161 to 180 LPS and head 61 to 70 M
Discharge 161 to 180 LPS and head 71 to 80 M
Discharge 161 to 180 LPS and head 81 to 90 M
Discharge 181 to 200 LPS and head 20 to 30 M
Discharge 181 to 200 LPS and head 31 to 40 M
Discharge 181 to 200 LPS and head 41 to 50 M
Discharge 181 to 200 LPS and head 51 to 60 M
Discharge 181 to 200 LPS and head 61 to 70 M
Discharge 181 to 200 LPS and head 71 to 80 M
Discharge 181 to 200 LPS and head 81 to 90 M
PHED BSR 2023/5.8/ Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.
Discharge 201 to 220 LPS and head 20 to 30 M
Discharge 201 to 220 LPS and head 31 to 40 M
Discharge 201 to 220 LPS and head 41 to 50 M
Discharge 201 to 220 LPS and head 51 to 60 M
Discharge 201 to 220 LPS and head 61 to 70 M
Discharge 221 to 240 LPS and head 20 to 30 M
Discharge 221 to 240 LPS and head 31 to 40 M
Discharge 221 to 240 LPS and head 41 to 50 M
Discharge 221 to 240 LPS and head 51 to 60 M
Discharge 221 to 240 LPS and head 61 to 70 M
Discharge 241 to 260 LPS and head 20 to 30 M
Discharge 241 to 260 LPS and head 31 to 40 M
Discharge 241 to 260 LPS and head 41 to 50 M
Discharge 241 to 260 LPS and head 51 to 60 M
Discharge 241 to 260 LPS and head 61 to 70 M
Discharge 261 to 280 LPS and head 20 to 30 M
Discharge 261 to 280 LPS and head 31 to 40 M
Discharge 261 to 280 LPS and head 41 to 50 M
Discharge 261 to 280 LPS and head 51 to 60 M
Discharge 261 to 280 LPS and head 61 to 70 M
Discharge 281 to 300 LPS and head 20 to 30 M
Discharge 281 to 300 LPS and head 31 to 40 M
Discharge 281 to 300 LPS and head 41 to 50 M
Discharge 281 to 300 LPS and head 51 to 60 M
Discharge 281 to 300 LPS and head 61 to 70 M
Discharge 301 to 325 LPS and head 20 to 30 M
Discharge 301 to 325 LPS and head 31 to 40 M
Discharge 301 to 325 LPS and head 41 to 50 M
Discharge 301 to 325 LPS and head 51 to 60 M
Discharge 301 to 325 LPS and head 61 to 70 M
Discharge 326 to 350 LPS and head 20 to 30 M
Discharge 326 to 350 LPS and head 31 to 40 M
Discharge 326 to 350 LPS and head 41 to 50 M
Discharge 326 to 350 LPS and head 51 to 60 M
Discharge 326 to 350 LPS and head 61 to 70 M
Discharge 351 to 400 LPS and head 20 to 30 M
Discharge 351 to 400 LPS and head 31 to 40 M
Discharge 351 to 400 LPS and head 41 to 50 M
Discharge 351 to 400 LPS and head 51 to 60 M
Discharge 351 to 400 LPS and head 61 to 70 M
PHED BSR 2023/7.1/ SITC DOL Starter type LT Panel of following rating, all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. complete as per Technical Specifications and as per direction of Engineer-In-Charge.
PHED BSR 2023/7.2/ SITC STAR DELTA Starter type LT Panel of following rating: all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.20 MB
BOQ_950959.xls
BOQ • 0.36 MB
TD91EPR.pdf
Tender Documents • 2.83 MB
Download all tender documents and submit your bid