Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.5 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹1.0 Cr+₹24.2 L (30.8%)Rejected-Finance A 04 ADGNJ CHANDAN NAGAR OPP IOCL PETROL PUMP RAMPUR ROAD BAREILLY U P 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance Over all rates are higher than L1. | |
| 3 | Rejected-Technical | - | Rejected-Technical Contractor not having category b (ii) hence not recommended for opening of 2nd cover. |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
22 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Bareilly
CWE AF Bareilly
PROVISION OF INFRASTRUCTURE FOR COMMERCIAL POWER SUPPLY TO MPR AT AF STATION BAREILLY
2021_MES_450858_1
81262/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bareilly
As per NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) Bareilly
₹2.1 L
Yes
24 Aug 2021
12 Jun 2021
24 Jul 2021
12 Jun 2021
22 Jul 2021
8 Jul 2021
12 Jun 2021 - 30 Jun 2021
60 days
Amount
Supply,laying, jointed and testing HT cable XLPE insulated, screened, PVC bedded, galvanised steel strip, armoured,electric power cable with aluminium conductor, 11000 volts (Earthed System), laid in trenches/ drawn through pipe/ poles or laid under road / drains / path complete of cross sectional area 95 sq. mm 3 core complete all as specified and directed. Note:- HT cable drum of lenghth 3x900RM long ordered to the manufacturer to be supplied. Standrad lenght of 500 RM Drum not be accepted.
Supply, laying, jointed and testing LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core, laid in trenches/ drawn through pipe/ poles or laid under road / drains / path complete all as specified and directed.
M & L Boring of holes under road, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm,complete all as specified and directed.
Supply, install, commissioning and testing of Transformer capacity 315 KVA,11/0.433KV 3phase 50Hz ONAN cooled oil immersed double copper wound outdoor type, , step down Transformer complete with first filling of IS 335 filtered and dehydrated transformer oil and other standerd fittings/accessories OFF LOAD tap changer tapping range up to + 7.5% in step of + 2.5 % BEE compliance level II The Transformer shall be of DYN -11 vector group and conforming to Latest IS-1180 all as specified and directed. Make :- ITE , Voltamp, CG
Excavation in trenches (Manually) not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables or foundation of electric pole / Stay assembly and getting out in soft / loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in each layer as in soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class HV type-I flat size 300 mmx180mmx40mm complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover class LV type-I flat size 250 mmx150mmx40mm complete all as specified and as directed.
M & L for laying of course sand free from sharp materials as in filling in trenches for cable protection, laid to a uniform thickness of 23 cm (15 cm under the cable and 8 cm over the cable) and gently punned down to 18 cm thickness as required complete all as specified and directed. Note :- Punned down thickness shall be measured for payment purpose.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized iron strip size 32x6mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earth work, G.I.pipe light grade 40 mm bore for protection of G.I.strip from earth electrode to and including the earth test point of galvanised iron /steel of size 75 x75x 25 mm , supplying and laying charcoal dust, common salt PCC 1:2:4 type B-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed. Note :- Cost of earthing strip & GI pipe 40mm up to 7.5 m shall be included in cost of above item.
S&F GI earth strip of size 32 x 6mm complete as earth lead of wall conductors/ buried in ground including screws etc. and connections with existing earth test point complete all as specified and directed.
Material & labour for Chemical earthing complete with copper plate electrode 900mm x 600mm x5mm burried directly in ground vetically to a depth not less than 4.70 mtr below normal ground level (with top edge of earth plate not less than 3.60 mtrs below ground level ) connected to copper strip 32 mm x 6 mm as main earthing lead by means of brass brazing at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil ,GI pipe medium grade 50 mm bore for protection of copper strip from earth electrode to earth test point of galvanised Iron / steel , adequate quality of charcoal dust, common salt and magnesium sulphate in alternate layers of 100 mm thick x 6 layers all around the plate , and RCC (1:2:4 type B1 using 20 mm graded crushed stone aggregate ) cover of size 54x54x50 mm reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel flushed type handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in drawing. Note a). Cost of copper strip and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items. b) On testing,after completion of job ,if desired earth resistence (less than 1 Ohm ) is not found ,the earthing shall be redone at no extra cost to govt.
M&L for earthing complete with Copper earth plate 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to copper strip size 20x3mm as earthing lead by means of bolt ,nuts, check nuts and washer of Copper/Brass as shown in drawing and including excavation and earth work, G.I.pipe light grade 40 mm bore for protection of earth strip from earth electrode to and including the earth test point of gun metal/bronze of size 75 x75x 25 mm , supplying and laying charcoal dust, common salt PCC 1:2:4 type B-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed. Note :- Cost of earthing strip & GI pipe 40mm up to 7.5 m shall be included in cost of above item.
S&F copper earth strip of size 32x6 mm fixed to wall or batten or recess or chases or buried in ground complete all as specified.
Supply, installation, testing and commissioning factory made LT feeder pillar box Outdoor type platform mounted of size not less than 1000X1200X450mm suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 800 Amps for phases and neutral, installed on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY)and made out of 3.15mm thick CRCA sheet Compartmentalized design and 50x50x6 mm angle iron frame ,four point lock with swing handle for door lock , cable entry provosion from bottom and made in three pert construction with galvanised steel, foamed in PU gaskit and hinge design allowed 120 degree door open complete all as specified. The scope of work includes provision of housing the following accessories:-
(A) Incoming : - (i) Supply and fix MCCB 500 Amp with , 4 Pole,36KA withmicroprpcesor based release - 01 No. (ii) Digital panel meter for Amp, Volt,KWH, power factor and other parameter - 1 set (iii) Indicating lamp LED type one set in incoming phases. (iv) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (B) Outgoing ways :- (i) MCCB 250 Amp, 4 Pole,25 KA 415 volts with microprpcesor based release------ 02 No. (ii) MCCB 200 Amp, 4 Pole,25 KA 415 volts with microprocessor based release ------ 01No.
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1200 (W) X1000 (Ht) (Without Canopy & Base channel) x 400 mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 800 amps insulated , Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables the Feeder Pillar shall be duly fabricated in a approved fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland ade of Brass CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) Supply and fix MCCB 500 Amp with , 4 Pole,36KA with microprocessor based release ----- 01 No. OUTGOING :- (i) Supply and Fix MCCB 500 Amps (35 KA) 4 Pole microprocessor based release --- 01 No MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE) Digital Multifunction meter - 01 No. Make : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 500/5, resin cast, - 03Nos.
Supply, installation, testing and commissioning factory made Automatic Power factor Correction (APFC) Panel of cap 100 KVAR indoor type platform mounted of size 1000X1200X450mm suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 400 Amps for phases and neutral, installed on porcelain / epoxy insulator 50 C/S AC supply to improve PF 0.70 to 0.99 or unity automatically step wise switch capacitor panel floor mounted out door type, weather proof dust/vermin proof protection IP-54 type made out of MS sheet 3.0 mm and angle iron 40mmx40mm 6mm frame factory made fabricated as modular in construction duly powder coated light grey colour painted, front openable panel shutter with locking arrangement to facilitate easy maintenance complete, natural air cooled cable entry with gland plate with provision of PCC 1:3:6 type C-I, 450mm below ground and 450mm above ground level all around legs complete , and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing the following accessories:-
(a) MCCB 250 Amp, 4 Pole,25 KA 415 volts with microprpcesor based release- 01 No (b) APFC microprocessor base relay 8 stage 144x144 mm ,415 volt (c) Protection devices (MCB) against short circuiting over loading and isolation in the unlikely events of failure in step switching single phasing protection low/high voltage protection in balancing protection with indicating lamps current sensors (CVTs)-01 set. (d) Naturally air cooled MPP double dielectric heavy duty 440 volt LV 50 HZ shunt power capacitors conforming to IS-13340 and 13341 and IEC 831-I, ISI marked designed on ambient temperature 10 degree to 50 degree celsius delta connections complete with metal base enclosure copper wire connection for banking complete with watt loss not more than 0.5 watt/KVAR complete No of stepping combinations of 50X1+25X1+15X1+5X2 (5 steps) KVAR each with contactor and MCCB complete or as directed by Engr-in-Charge. (e) Int. wiring with adequate size of PVC insulated copper multistranded cable with necessary lugs thimbles/glands-01 Job. Note : The APFC panel should be so designed to accommodate 10% extra space only for future expansion. (f) The rate quoted shall deemed to include for cable connection incl. cable glands and earth connection with GI strip 25X6mm (as per current capacity) including necessary jointing material to existing earth lead.
Supply and fix Automatic transfer switch I - O - II operation 400 Amps with bridging bars and handle with sheet matel inclosure of suitable size included Automatic operation, equipped with OMD800 controller unit with display complete all as specified and directed.
Supply and laying XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables with stranded Copper conductor, 1100/650 volts grade as per IS 7098 (Part I) of size 240 sqmm 3.5 Core complete all as specified and directed.
Supply, install, commissioning and testing of Isolation transformer of cap 315 KVA three phase 415 volts 50 Hz ONAN type cooled oil immersed copper wound indoor type complete with first filling of IS; 335 ISI marked filtered & Dehydratad Transformer oil electrostatic shield between primary 415 V in Delta connected & secondray 415V Star connected complete & other standard fitting / accessories with vector group symbol Dyn-11 , cable box on in comming and out going with cable gland complete all as specified and directed. Make ITE, AE, VOLINA
Supply, Installation of Perforated GI Tray 1.50 mm thick with suppporting hangers, ties & complete with all standard accessories of Size : 500mm wide x 150 mm height complete all as specified and as directed.
Supply & fix cable route indicator made out of 40mm x 40mm x4mm mild steel angle iron 1 metre long and mild steel plate of size 100mm x 150mm x 6mm welded only on one side and having embosed on plate as cable HT including PCC 1:2:4 type B1 of size 30cmx30cmx30cm and embedding angle iron including excavation and earth work complete all as specified and directed.
Material & labour for brick masonary plateform of size 2.5x2.5x1 m hight brick masonary built in CM(1:6) above ground level 150mm thick PCC(1:5:10) type E2 in foundation having projection of 150 mm on both side of wall 300 mm Brick masonary brought to course in CM(1:6), 0.6 m depth below GL. plateform shall be 1 m above GL, Brick masonary shall be pointed with fluse pointing in CM(1:3) floor shall be of 50mm thick PCC(1:2:4) type B1 laid over 100mm thick hard core cover approved earth complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed
M & L for plain Cement Concrete type D-2 1:4:8 (using 40 mm graded stone agg) in foundations, filling and mass concrete complete all as specified and directed.
S & F for Joist, channel, angle, tee/flat or other sections, including cutting tops to shapes as directed drilling holes ,notching for wire etc and simillar work conforming to of Fe 290 Gde-E-165 etc all as specified and directed
M & L for prepration of new steel surface and applying two coats of synthetic enemal paint over one coat of primer complete all as specified and drected.
Fixing only Chain link fencing in patch incl line wires any mesh size and type to any type of standard rail ,staining bolts etc incl provn of binding wire complete all as specified and directed.
Supply only Chain link Mild steel PVC coated green colour fencing 4mm dia of wire any size of mesh or type as required at site complete all as specified and directed.
Supply only for 10 mm dia mild steel round bar for line wire of Chain link fencing complete all as specified and directed.
S & F for MS bolt 12mm dia purpose made with hexognal or square head one end and scured and other or screwed both end each scewed end to be fitted with 2 washers and one hexonal or square exc 10cm and n exc 15cm long etc complete all as specified and directed.
S&F MS framed work such as doors or gates of angle or other section with gusset plates , MS sheets etc conf to Fe-290 (Gde E-165) complete as design passed by Engr-in-charge all as specified and directed
Supply and install split AC with copper condenser coil, Inverter Type indoor / outdoor complete with cordless remoe control unit of capacity 2.0 TR 3 star with mounting bracket complete all as specified and directed. Make-Blue Star Model / Hitachi / Carrier / Voltas
Supply & Install automatic voltage stabilizer wall mounted single phase 50 cycles AC supply complete with volt meter and designed for input voltage of 160 volts to 260 volts and out put voltage stablized between 230 volts + 10% of capacity 5 KVA with high low voltage and time delay relay complete all as specified and as directed. Make V Guard, Blue Bird, Microtek
M&L sub main wiring 3run of 2.5 sqmm PVC insulated but unsheathed FRLS cable of specified size with multi stranded copper conductors650/1100 Volts grade IS: 694 marked drawn through and incl suitable size of rigid non metalic PVC conduit medium grade ISI marked (not less than 20 mm dia ) with fittings & accessories complete all fixed/laid conceated in wall and surface conduit on ceiling and also including complete all as specified and directed.
S&F sheet metal single pole and neutral enclosure with two pin and earth plug with socket capacity 20-32 amps complete with one No SP MCB capacity 20-32 amps complete all as specified and directed.
BHARAT ELECTRICAL TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .