Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 CrAccepted-AOC | ₹4.9 Cr Quoted ₹5.0 Cr | L1 | Accepted-AOC Accepted because he is L1 bidder |
| 2 | L2₹5.0 Cr+₹1.7 L (0.34%)Rejected-AOC | ₹5.0 Cr+₹1.7 L (0.34%) | L2 | Rejected-AOC Rejected because he is L2 Bidder |
| 3 | L3₹5.1 Cr+₹16.5 L (3.34%)Rejected-AOC | ₹5.1 Cr+₹16.5 L (3.34%) | L3 | Rejected-AOC Rejected because he is L3 Bidder |
Tender Value
₹5.3 Cr
EMD Value
₹10 L
Closing Date
19 May 2020, 5:30 pmClosed
MD cum CEO
Dharamshala Smart City Ltd Old HIMUDA Building CHilgari Dharamshala HP
CONSTRUCTION OF MULTI-LEVEL PARKING AT MCLEODGANJ NEAR DALAI LAMA TEMPLE IN DHARAMSHALA
2020_DSCL1_36045_1
DSCL/I-PR/52/2018-1807
Open Tender
Chemicals/Minerals
Item Rate
450 days
Dharamshala
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
MD cum CEO
₹10 L
Dharamshla Smart CIty Office
4 Sept 2020
7 Mar 2020
20 May 2020
7 Mar 2020
19 May 2020
7 Mar 2020
18 Mar 2020
Amount
Clearing jungle including uprooting of rank vegetation, grass,brush wood, trees and saplings of grith upto 30 cm. measured at a height of 1 metre above ground and removal of rubbish and disposal at all leads and lifts outside the periphery of the area cleared.
Earth work in excavation by mechanical means /manual means for levelling areas including getting out and disposal of excavated earth to all leads and lifts as directed by Engineer-in-charge in All kind of soil
Excavation in foundations, trenches etc., in earth work and stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundations etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed to all lifts and leads.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification
Providing and laying cement concrete M10 grade and curing complete including cost of form work in:-Foundation and plinth
Providing and laying reinforced cement concrete M20 grade including cost of form work and curing complete excluding reinforcement for Reinforced concrete work in:-Foundation footings bases of columns and the like and mass concrete.
Providing and laying reinforced cement concrete M20 grade including cost of form work and curing complete excluding reinforcement:-Lintels, beams girders bressumers and cantilevers
Providing and laying reinforced cement concrete M20 grade including cost of form work and curing complete excluding reinforcement:-Column, pillars, posts and struts
Providing and laying reinforced cement concrete M20 grade including cost of form work and curing complete excluding reinforcement for reinforced concrete work in:-Wall (any thickness but not less than 0.1 m thickness) attached pilasters, buttresses, plinth and string courses etc.
Providing and laying reinforced cement concrete M20 grade including cost of form work and curing complete excluding reinforcement for Reinforced concrete work in:-Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilevers
Providing and laying reinforced cement concrete M20 grade including cost of form work and curing complete excluding reinforcement for Reinforced concrete work in:-Stair cases and ramp including preparing of the surface and finishing of nosing
Providing mild steel/Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level :
Brick work using common burnt clay building bricks inSuper-structure above plinth level upto floor two level (First Class Bricks). :-Cement Mortar 1:4 (1 cement:4 sand) Second Class Bricks
Half brick masonry in common burnt clay building bricks in :- super-structure above plinth level upto all level.
Providing woodwork in frames of doors,windows,clerestory,windows and other frames wrought,framed and fixed in position.:-2nd class deodar wood.
Providing and fixing flush door shutters interior grade, commercial type, core of block board construction with frame of first class hard wood and well matched commercial ply veneering with vertical grains of cross bands and face veneers on both faces of shutters.:-35mm thick including black enamelled M.S.butt hinges.
Providing and fixing aluminium 2 track Sliding window and ventilator including 4 mm toughened clear glass with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically where ever required including cleat angle, aluminium, snap beading for glazing/panelling C.P. brass/stainless steel screws. All complete as per architectural drawings and the directions of Engineer-In-Charge.
Providing and fixing aluminium fixed/curtain window including 5 mm toughened clear glass with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically where ever required including cleat angle, aluminium, snap beading for glazing/panelling C.P. brass/stainless steel screws. All complete as per architectural drawings and the directions of Engineer-In-Charge.
Providing and fixing M.S. pressed but hings with necessary screws. (Copper oxidised) 125x65x2.12mm
6mm Cement plaster to ceiling:-In Cement mortar 1:3 (1 Cement : 3 Sand)
15mm Cement plaster in single coat on the rough side of brick/ concrete/stone walls for interior plastering upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth.:- Cement Mortar 1:6 (1Cement:6 Sand).
15mm Cement plaster in single coat on the rough side of brick/ concrete/stone walls for interior plastering upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth.:- Cement Mortar 1:6 (1Cement:6 Sand).
Providing and laying wearing coat of 25 mm cement concrete flooring 1:2:4 (1 cement: 2 sand :4 stone aggregate of size 12.5 mm and below) laid over concrete slab already laid and finished with a floating coat of neat cement as per specifications and as directed by the Engineer
Kota stone slab flooring 20 mm (average) thick base of cement mortor 1:4 (1 cement :4 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. including rubbing and polishing and moulding the edges complete for staircase and cabin
Providing and laying ceramic glazed tiles 6 mm thick in toilet walls with 12 mm thick cement mortar 1:3 (1 cement :3 sand) and jointed with cement slurry.
Providing and laying spartic ceramic tiles 5.5 mm thick (300 x 300mm. In size) on toilet floor with laid on a bed of 12mm. thick cement mortar 1:3 (1cement : 3 sand) finished with flush pointing in white cement.
Providing and laying granite stone in flooring 20mm(average) thickness base of cement mortar 1:3(1cement: 3 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of granite stone i/c rubbing and polishing and moulding the edges complete.for counter tops
Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete.
Applying priming with cement primer coat on new concrete / masonry / asbestos cement / plastered surfaces after and including preparing the surface by thoroughly cleaning oil,grease,dirt and other foreign matter and sand papering as required with :-Readymixed Cement Primer
Wall painting (two coats) with acrylic emulsion paint of approved brand and manufacture for interior grade on undecorated concrete /stone /plastered wall surfaces to give an even shade including t horoughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth including applying of putty a required for metling the surface
Finishing wall with weather proof exterior grade emulsion of approved design (Apexultima) or its equivalent on undecorated wall surfaces (two coats) to give an even shade and final finish after throughly cleaning the surface to remove all dirt, dust and other foreign matter etc including sand paper smooth complete.
Painting lines,dashes,arrows, letters etc.on roads,air fields and like in two coats with road marking paint,brushing,including cleaning the surface of all dirt,dust and other foreign matter
Steel work welded in built-up sections,trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of red lead paint:-In beams joists channels ,angles , tee ,flats with connection plates or angle cleats as in main and cross beems,hip and jack rafters,purlins connected to common rafters and the like.
Steel work welded in built-up sections,trusses and framed work, including cutting,hoisting,fixing in position and applying a priming coat of red lead paint:-In grating, Framed guards, bars,ledders railings,brackets & similar works.
Painting two coats (excluding priming coat)on new steel and other metal surface under coat with ready mixed paint brusing to give an even shade including cleaning the foreign matter :-With readymixed paint other than white
Providing and fixing 0.60mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with all accesoriees as required as per the direction of Engineer-in-charge.
Providing and fixing ridges or hips 60 cm overall with 0.60mm thick prepainted steel sheets in roofing with hot dipped metalic zinc coated sheets with top coat of regular modified polyster organic coating of 20 microns over 5 microns primer coating + back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts & nuts 6mm dia & prepainted G.I. limpet and bitumen washers complete with all accessories as required as per the direction of Engineer in Charges.
Providing and laying 60 mm thick heavy duty precast cement conrete inter locking paver blocks vibro compacted upto M-50 grade i/c border or kurb block grey or coloured over sub-base of concrete with 25mm thick average thickness of cement mortar 1:4 (1 cement : 4 sand) laid over and jointed with neat cement slurry mixed with pigment to match the shade of blocks i/c curing rubbing & polishing complete (Sub base concrete floor to be paid for separately)
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Providing and fixing high pressure PVC Spigot and Socket, waste and ventilating pipe ISI Marked including fixing with approved adhesive complete.
PVC Pipe 150 mm dia
PVC Pipe 110 mm dia
PVC Pipe 75 mm dia
Providing and fixing PVC Plain bend ISI Marked including fixing with approved adhesive complete :-
PVC Plain bend 110 mm dia
PVC Plain bend 75 mm dia
Providing and fixing PVC door bend with oval acess door, insertion rubber washer 3 mm thick bolts and nuts ISI marked complete including fixing with approved adhesive complete :-
PVC Door bend 110 mm dia
PVC Door bend 75 mm dia
Providing and fixing PVC floor trap ISI Marked of self cleaning design including fixing with approved adhesive, cost of cutting amd making good the walls and floor etc. complete:-PVC Floor Trap 110x75 mm dia
Providing and fixing PVC Single Equal Branch with oval access door, ISI Makred insertion rubber washer 3 mm thick bolts and nuts complete inclusing fixing with approved adhesive etc. complete
110 mm dia
75 mm dia
Providing and fixing PVC Collar ISI Marked including fixing with approved adhesive complete :-
150 mm dia
110 mm dia
75 mm dia
Providing and fixing PVC Clamps ISI Marked of approved design with steel screw and rawal plug etc.complete :-
110 mm dia
75 mm dia
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :-With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing white vitreous china extended wall mounting water closet of size 790x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing Health faucet ABS with rubbit cleaning system, flexible tube upto 1.25 mtr. long PVC Flexible tube & ABS wall hook to extended wall mounted type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing Oval Shape wash basin on R.C.C Slab, including 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, and making good the walls wherever require:-White Vitreous China oval shape Wash basin size 540x410 mm with 15 mm C.P. brass pillar taps
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board of size 610x510 mm bowl depth 200 mm as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Providing and fixing P.V.C. Flexible pipe waste pipe for sink or wash basin including:-P.V.C. waste fittings complete.:- 32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge:-32 mm nominal outer dia Pipes:-32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall:-25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge:- Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm Long
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing C.P. Brass Towel rail complete with C.P. Brass brackets fixed to wooden plugs with C.P. Brass screws :600x20mm
Providing and fixing 600mm x 120 mm glass shelf with C.P. Brass bracket and guard rail complete, fixed to wooden plugs with C.P. Brass screws.
Providing and fixing chromium plated brass soap dish with C.P. Brass brackets fixed to wooden cleats with C.P. Brass screws :-
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :-20 mm nominal bore
32 mm nominal bore
25 mm nominal bore
Supply and Installation of 8 Passenger lift complete all required accessories as per drawing and manufacturer's specification and as per direction of Engineer-incharge
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group- A.
Group- C
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Wiring for light/plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and fixing brass batten/angle holder including connections etc. as required:-
Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required.
Providing and fixing Box type, 1200 mm straight linear LED tubelight suitable for 18 watt LED Tubelight , complete with all accessories, connections, testing and commissioning etc. as required.
Providing and fixing of LED Bulb Retrofit range in the existing fitting, complete with all accessories, connections, testing and commissioning etc. as required.
LED Bulb 9 Watt pin type
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. ISI marked , with 4 or 5 * star rating approved from BEE, as required:-
Ceiling Fan 1400 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, ISI marked , with 4 or 5 * star rating approved from BEE, testing and commissioning etc. as required:-
15 Liter capacity water heater (Cat-A)
Providing, Installation, testing and commissioning of 40 watts LED street lighting luminaires, with deep drawn CR Steel body, power coated, clear acrylic cover, aluminium reflector and accessories, including street light bracket made of 32 mm dia. G.I. pipe 'A' heavy class of suitable length and dia, the pipe bended to give a beam angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coatas required complete all as per drawing and technical specification and as per direction of Engineer-in-charge.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 16 sq. mm (four core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 10 sq. mm (four core)
Providing, laying and fixing of one No. copper conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
PVC insulated Copper Fexible Cable 4 sq.mm, Three Core
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-
32 mm. dia
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-
300 mm deep (nominal)
Supplying and fixing Aluminum alloy or wrought aluminium strip bus-bars, suitable for 63 Amp. 415 volts capacity 4 No. each of cross-sectional area (25mmx4mm), in the existing enclosure or cubical panel with all accessories including connections etc. as required:-
Supplying and fixing of Digital Ammeter and Volt Meter Suitable For Control panel Box.
Supplying and fixing of R,Y, B Indicators For Control panel Box.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-8 way
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision for 4-pole MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-8 way (8+24),horizontal type
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. Cat-A.
Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. Cat-A.
Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amp. Category-A
Earthing with G.I earth pipe 4.5 mtr. long and 40 mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required . Earthing system standrad must be as per IS 3043:1987, IS 3043: 2018 or equivalent IEC code.
Extra for using salt and charcoal for pipe earth electrode complete as required.
Providing and laying earth connections from earth electrode with 6 SWG G.I. Wire in 15 mm dia. G.I. pipe from earth electrode etc. as required.
3-Phase Smart Energy Meter DLMS Whole Current type in side waterproof meter box
Providing, laying, testing & commissioning of 'C' class heavy duty 50 mm MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp /support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required as per drawing and technical specification and as directed by Engineer-in-charge
Supplying and fixing 30 meter first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket complete as requiredas per drawing and technical specification and as directed by Engineer-in-charge
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing 50 mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes for external work, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
Providing and fixing 50 mm Nominal bore CPVC Ball valve with of approved quality
Supply and installation CO2 fire extinnguisher 4.5 kg capacity ISI marked confirming to IS:15683 operating temperature -30ºC to 55ºC for class 8B type of fire fitted with PVC bend horn complete in all respect and B & C class fire-inflammable liquids, gaseous fire like L.P.G and acetylene and electrical fires complete all as per technical specification and direction of Engineer-in-charge
Supply and installation KANEX or equivalent ABC Type Fire Extinguisher Cap. 4 kg Filled with Mono Ammonium Phosphate Powder 50% confirms to IS 14609, Stored Pressure Type, UGTS Pressure Gauge, Gross Weight 6.6 Kg, Empty Weight 2.6 Kg, Can Height 490mm, Diameter 140 ± 10mm, Discharge Time 18 Sec, Controllable discharge mechanism, Jet Range 3 Meters, Average Discharge is 90%, applicable on Class A,B & C and electrically started Fire, A Rating- 2A, B Rating 21B, Can Construction : Deep drawn & CO2 Mig welded, EPDM Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating, External Coating - Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Sheet metal thickness : 1.8 mm, ISI Approved IS 15683 : 2006 complete all as per technical specification and direction of Engineer-in-charge
Excavation in foundations, trenches etc., in earth work, lift upto 1.50 Metres stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundations etc. onsolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 metres.
Providing and laying cement concrete 1:5:10 (1cement :5sand :10 graded stone aggregate 40mm. nominal size) with 15 % plum and curing complete including cost of form work in retaining walls/ Breast walls, the size of plums shall usually be 150mm. to 300mm. as per H.P.P.W.D. Specification.
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
Back filling behind abutment, wing wall and return wall complete with approved borrow granular material as per drawing and Technical Specification
Level 9 Biz Pvt Ltd
Vidya Infrastructure and Developers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .