Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.1 LAccepted-AOC D25 AMBATTUR INDUSTRIAL ESTATE CHENNAI TIRUVALLUR TAMIL NADU 600058 | CHENNAI | TAMIL NADU | 600058 | 1 | Accepted-AOC L1 |
Tender Value
Refer Docs
Closing Date
19 Dec 2024, 3:00 pmClosed
DIRECTOR
CSIR-CECRI, KARAIKUDI
CECRI01102024MMP035201 W9 (WP4)7 - HEAT RESISTENCE PAINT TESTS AT NABL ACCREDITED LABORATORY
2024_CSIR_215666_1
CECRI01102024MMP035201 W9 (WP4)7 - HEAT RESISTENCE PAINT TESTS AT NABL ACCREDITED LABORATORY
Open Tender
Miscellaneous Services
Item Rate
120 days
KARAIKUDI
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
Exempted
19 Mar 2025
21 Nov 2024
20 Dec 2024
21 Nov 2024
19 Dec 2024
21 Nov 2024
Amount
List of Tests
Odor Test - as per standerd ASTM D1296
Volatile organic compounds VOC content - as per standerd ASTM D2369- IS 101 Part 8-sec 2
Pot life and Viscosity of HRP mixture - as per standerd BS EN ISO 2431 or ASTM D 1200 or IS101 Part 1 Sec 5
Drying time - as per standerd ASTM D1640 or IS 101 Part 3, Sec 1
Density - as per standerd ASTMD1475 or IS 101 Part 1, Sec 7
Specular gloss - as per standerd BS 2782-5 520A or IS- 101-PART-4-SEC-4
Dry film thickness - as per standerd ASTM E376 or ASTM B499
Bend- Flexibility test room Temperature - as per standerd ASTM B571 or IS 101 Part 5 Sec 2
Bend- Flexibility test Low Temperature - as per standerd IS 101 Part 5 Sec 2 for reference
Adhesion cross hatch - as per standerd ASTM D 3359 Test Method A-B or BS3900-Part E6, 1 mm spacing
Adhesion Dolly test - as per standerd ASTM D4541
Hardness Scratch test - as per standerd ASTM D3363 - IS 101 Part 5 Sec 1
Water Resistance - as per standerd ASTM D870 for 168 Hrs
Fuel Resistance (ATF K-50) - as per standerd ASTM D 6943
Gearbox oil Resistance (OEP-70) - as per standerd ASTM D 6943
Hydraulic Oil (H-515) - as per standerd ASTM D 6943 for 168 h at 40 C
Grease Resistance (G382, G366, G355) - as per standerd ASTM D 6943 for 168 h at 40 C
Weather resistance - as per standerd ASTM G155 Duration 500 h Chamber condition: Temp: 42 ±3 °C
High Temperature Test - as per standerd MIL-STD-810G Method 501-5 for 24 hour Temperature up to 200 °C
Low temperature - as per standerd Test MIL-STD-810G Method 502-5 Procedure-II 4 h
Salt Spray - as per standerd MIL-STD-810 G Method 509-5 for 96 h
Combined Altitude Temperature and Humidity test CATH - as per standerd MIL-STD-810G (cycles: 10 cycles) (1 cycle=16 h)
Resistance to dust - as per standerd MIL-STD-810G Method 510-5 JSS 55555 Test No 14
Resistance to rain driving rain - as per standerd MIL- STD-810G Method 506-5- JSS 55555
Vibration Test - as per standerd MIL-STD-810G Method 514-6 (Main rotor frequency: 5.88Hz f=5.88Hz, A 1=0.144g f1 =17.65Hz, A2=1.765g)
Thermal shock - as per standerd MIL-STD-810G Method 503-5 Procedure I-B
Humidity resistance - as per standerd MIL-STD-810G, Method 507-5
Icing-freezing rain - as per standerd MIL-STD-810G Method 521-3- JSS 55555
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .