| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹38.8 L+₹10,733.90 (0.28%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹35.2 L
Closing Date
13 Nov 2021, 6:00 pmClosed
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA NO CWE /HILLS /RKT/56 OF 2021-2022 PROVN OF 250 KVA TRANSFORMER FOR OXYGEN GENERATION PLANT AT RANIKHET UNDER GE RANIKHET
2021_MES_477042_2
CA NO CWE / HILLS / RKT/56 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
RANIKHET
CLASS D
9 documents required · 9 mandatory
₹500
GE RANIKHET
Yes
23 Nov 2021
23 Oct 2021
15 Nov 2021
24 Oct 2021
13 Nov 2021
1 Nov 2021
24 Oct 2021 - 31 Oct 2021
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/ dense soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified and as directed.
Removing excavated material (soils) n .exc 50 m and depositing, where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M&L precast cement concrete block masonary with solid blocks type C1 1:3:6 20mm graded stone aggregate exc 10cm in width and setting in mortar 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L 15 mm thick cement plaster on fair faces of brick work or concrete surface on wall in CM 1:6 finishing the surface even and fair complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4 type B0, 12.50 mm graded stone aggregates, louvres and jallies, 25mm thick (mea sured solid), including all mouldings but excluding frame (Precast frame shall be measured separately and paid) complete all as specified and directed.
M&L for RCC 1:2:4 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC 1:2:4 using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 20 mm graded stone aggregate in benching, coping including necessary form work, weathering, slightly rounded for chamfered angles and throating complete all as specified and directed.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing Fe 410-W Gde E250 quality A complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat concrete surfaces complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat concrete surfaces complete all as specified and directed.
M&L rendering 10mm thick in cement mortar 1:4 on brick work or concrete surfaces complete all as specified and directed.
M&L for RCC type B1 1:2:4 using 20 mm graded stone aggregate, slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough surfaces of concrete flat complete all as specified and as directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide rough surfaces of concrete flat complete all as specified and as directed.
M&L for providing precast cement concrete type B1, 1:2:4 using 20 mm graded stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/ dense soil complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-290 Gde E-165 complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of walls including cornices etc by brooming down or steel wire brushing scraping down smoke soot moulds moss and efflorescent salt and trading oil and greasy and applying two coats of cement based paint complete all as specified and directed.
M&l for 150mm thick cement concrete 1:2:4 type B2 using 40 mm graded stone aggregate as in road standing etc laid in penals with including necessary formwork as required and finishing the surface of concrete, path road using extra cement complete all as specified and as directed.
M&L for 80mm thick coloured rubber pressed glossy finish precast concrete interlocking tiles of approved pattern & shade ISI marked approved by GE set jointed over 40mm thick fine sand cushion including sides are tappered 75 mm in width by PCC 1:3:6 type 1:3:6 type C1 using 20mm graded crushed stone aggregate complete all as specified and direcetd.
M&L for 75 mm thick PCC 1:3:6 type C-2, (using 40mm graded stone aggregate) as in plinth protection laid in alternate panels finished even and smooth without using extra cement complete all as specified and as directed.
Supply, installation, testing and commissioning of Transformer Step-down 11 KV/433V out door type copper wound oil cooled type transformer of capacity 250 KVA off load tap charger with +/- 7.5% tap charger insteps of 2.5% with vector group DYN-11. The transformer shall be provided with HT bushing set of 3 Nos with brass nut and bushing, set of 3 Nos with brash nut and washers including first filling of new transformer oil complete in all respect of following capacity including standard fitting and fixtures as under:- (i) HV Primary side consisting of 03 Nos porcelain bushing with bushing rods and nuts washers. (ii) 01 Nos Cable End box on LV secondary side consisting of 04 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for reception of cable of sizes LT 1100 V grade XPLE insulated heavy duty including gland point complete. (iii) Oil Conservator with filter type drain valve and oil level gauge. (iv) Dehydrating Breather with first filling of Dehydrating Agent. (v) Explosive Vent (vi) Thermometer pocket. (vii) Two Earthing Terminal on tank body to facilitate fixing of 32x6mm GI Strips. (viii) One No. Thermometer Dial Type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting divide to maximum temperature including needle to temperature gauge: Max reading painted terminal.
(ix) Rating plate with terminal plate. (x) Oil level gauge. (xi) Oil drain filter valve. (xii) Oil filling port on top cover with plug. (xiii) Air release valve/plug. (xiv) 4 Nos plain solid cast steel detachable rollers. (xv) Extra Bushing for natural outside the Cable Box and providing independent earthing for neutral. (xvi) First fill of transformer oil conforming to relevant ISI and tested upto 60KV dielectric strength. Note: Transformer shall be fixed on PCC platform with including PCC 1:3:6 type C 2 with 40mm graded stone aggregate of size 2.80x2.80x1.20 mtrs high or including necessary foundation work of appropriate size as directed or as per manufactures recommendation. Concrete to be deemed its above said items.
Supply, laying & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 120 sqmm complete all as specified and as directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
S&F of air break gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps,11KV with locking arrengement drop out fuse unit type carries and fuse element of required capacity including connceting OH HT & UG HT cable complete all as specified and as directed.
S&F steel tubular electric pole, swaged type, welded type, 410 SP-55 (11 meter long) complete with CI base plate, pole cap, bolts, nuts & screws all as specified including the following:- (i) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in hard / dense soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 meters. (ii) M&L for providing PCC 1:4:8, type D-2 ( using 40 mm graded stone aggregate) in base of pole of size 600mm x 600mm x 150 mm all as specified and directed. (iii) M&L for providing PCC 1:3:6, type C2 ( using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1800 mm (sub base as mass concrete) for concrete encasing the pole up to GL all as specified and directed. (iv) M&L for providing PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia or as directed by EIC complete all as directed and as specified. (v) M&L for painting of pole externally with two coats of black bituminous paint up to planting depth. The remaining portion of exterior shall be painted with one coat of red oxide primer and above plinth block/ concrete collar with two coats of aluminium paint including preparation of surfaces including painting of 30 cm wide black and yellow bands (strips) 5 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block and writting pole number and feeder location by white synthetic enamel paint with proper letter size as directed.
S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made out of flat iron 25x3mm, bolts and nuts of approved size for HT 25 x 20 cm size complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed. Note :- Thickness of sand cushioning shall be measured after punning.
Supply and laying old size burnt bricks, sub class B laid dry in trenches across the cable protection complete all as specified and directed.
M&L for galvanised iron strip 32 x 6mm buried in ground complete all as specified and as directed.
Supply and laying GI steel tube light grade of 100mm bore including all fittings, laid under floor/ road or fixed with poles/ walls for protection of cable complete all as specified and directed.
Supply and laying GI steel tube light grade of 80mm bore including all fittings, laid under floor/ road or fixed with poles/ walls for protection of cable complete all as specified and directed.
M&L for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amp, HT 11000 Volts grade complete all as specified and directed.
M&L for earthing complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 4.5 mtrs below ground level) with top edge of the plate not less than 3.75 mtr below normal ground level connected to galvanised earth strip as earthing lead (40x6mm) by means of bolts nuts check nuts and washer of galvanised iron/steel connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate wetering pipe 20 mm dia GI medium grade GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6 mm dia @ 150 c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40 mm dia lightt grade upto 7.5 mtr from electrode and engraving of earth making near by structure/painting of earth results etc, compete all as specified indicated on electrical plate No-1 SSR Part-I 2009 and as directed including testing on completion complete all as specified and directed.
Supply, laying & testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 400 sqmm 3.5 core complete all as specified and as directed.
M&L Voltage stabilizer for automatic operation, three phase naturally oil cool outdoor type and designed for input variation between 300 volts to 450 volts without put voltage stabilized at 415 volts with accuracy plus minus 1% and speed correction 8 volts per second and capacity 300 KVA suitable for both balanced and unbalanced load with bypass arrangements, with high voltage cutoff and short circuit protection complete including necessary foundation work and tin shed of appropriate size complete all as specified and as directed.
S&F end termination joint of 1.1 KV of size 400 Sqmm complete all as specified and as directed.
Supply, laying & testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core complete all as specified and as directed.
Supply, laying & testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 150 sqmm 3.5 core complete all as specified and as directed.
Supply, laying & testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 sqmm 3.5 core complete all as specified and as directed.
kumar automobiles
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .