Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.3 Cr
EMD Value
₹3.1 L
Closing Date
5 Dec 2026, 4:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Chief Engineer Project Brahmank, C/o 99 APO
HQ Chief Headquarter Project Brahmank,Ranaghat, Pasighat
SUPPLY, INSTALLATION AND COMMISSIONING OF COMBINED AIR-CONDITIONING AND DX TREATED FRESH AIR HANDLING UNIT SYSTEM FOR THE OFFICE CUM ADMIN BUILDG AT HQ CE (P) BRAHMANK OF AP INCL COMPREHENSIVE OPERN AND MAINT FOR FIVE YEARS AFTER COMPLN OF DLP
2026_BRO_798811_1
CE (P) BMK/12/2026-27
Open Tender
Civil Works
Works
120 days
Chief Headquarter Project Brahmank, Pasighat
As per tender document
8 documents required · 8 mandatory
₹0
₹3.1 L
Yes
HQ Chief Engineer Project Brahmank, Pasighat
14 Nov 2026
14 Nov 2026
7 Dec 2026
15 Nov 2026
5 Dec 2026
20 Nov 2026
16 Nov 2026 - 18 Nov 2026
19 Nov 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Variable Refrigerant Volume System:
Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 0C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity 40 and 70 ISEER 5.6 for ECSBC Building) For Cooling or Heating or Both | - | - | - | - |
| 1.02 | Out door VRV Unit 30 HP capacity | 3 | Nos | - | - |
| 1.03 | Out door VRV Unit 34 HP capacity | 5 | Nos | - | - |
| 2INDOOR UNIT-4-WAY CASSETTE TYPE: Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete as per CPWD specification, connections, inter connections etc. as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) | |||||
| 2.01 | 1.0 TR | 1 | Nos | - | - |
| 2.02 | 1.3 TR | 12 | Nos | - | - |
| 2.03 | 1.6 TR | 22 | Nos | - | - |
| 2.04 | 2.0 TR | 8 | Nos | - | - |
| 2.05 | 2.6 TR | 3 | Nos | - | - |
| 2.06 | 3.2 TR | 6 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.21 MB
80346TD.pdf
Tender Documents • 1.77 MB
Final_Office_Hvac-Model.pdf
Additional Documents • 1.69 MB
Final_Office_Hvac-Model2.pdf
Additional Documents • 1.10 MB
Final_Office_Hvac-Model4.pdf
Additional Documents • 1.39 MB
Final_Office_Hvac-Model3.pdf
Additional Documents • 0.82 MB
Final_Office_Hvac-Model5.pdf
Additional Documents • 0.39 MB
Final_Office_Hvac-Model6.pdf
Additional Documents • 0.39 MB
BOQ_896158.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .