Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAdmitted-Finance PLOT NO 234 BBN ENERGY SYSTEMS PRIVATE LIMITED 234 SECTOR 37 PHASE VI UDYOG VIHAR GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | L1 | Admitted-Finance | |
| 2 | L2₹2.7 Cr+₹27.8 L (11.3%)Admitted-Finance 10 10 VARAHI INDUTRIAL ESTATE NR GOTA RAILWAY CROSSING GOTA AHMEDABAD GUJARAT 382481 INDIA | AHMADABAD | GUJARAT | 382481 | L2 | Admitted-Finance | |
| 3 | L3₹3.1 Cr+₹58.5 L (23.7%)Admitted-Finance 1 8 37 C ESHWAR REDDY NAGAR NEAR AURORA DEGREE COLLEGE LANE SAI BABA LANE CHIKKADPALLY HYDERABAD HYDERABAD TELANGANA 500020 | HYDERABAD | TELANGANA | 500020 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical 116 RUNWAL DIAMOND OPP PALACE ORCHARD N I B M UNDRI ROAD MOHAMADWADI PUNE 411 060 | PUNE | PUNE | MAHARASHTRA | 411060 | - | Rejected-Technical Techno commercially not acceptable |
| Sl No | Description | Qty | Unit | R Pandurangam and sons L3 | JITENDRA ELECTRICALS L2 | BBN ENERGY SYSTEMS PVT LTD L1 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation & Commissioning of LT power distribution Panel: LT power distribution panel indoor type, front operated, fixed type construction, fully compartmentalized, hinged doors at front and rear with screw type knobs, separate hinged doors for incomer and each individual outgoing feeder. Indoor floor mounted with bus bars access from front and cable termination access from rear side. Cubical type uniform depth throughout the panel. As per attached Annexure-1 for technical specification and scope of work. | ||||||
| 1.01 | Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without MCCBs)
i)MCCB, 3 pole, 400A, 36 KA as incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 125A, 16KA-10 Nos
Panel shall be designed as per Sl. No.1 of specification. | 4 | Each | 3,00,000 ₹12,00,000 | 2,65,800 ₹10,63,200 | 2,24,229.5 ₹8,96,918 Lowest |
| 1.02 | Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 800 amps, 4 pole,50 KA,manual draw out type as Incomer. and the following as outgoing MCCBs
ii) MCCB, 3 pole, 250 A, 36KA -2Nos
iii) MCCB, 3 pole, 160A, 36KA-4 Nos.
iv) MCCB, 3 pole, 125A, 16KA-4 Nos.
Panel shall be designed as per Sl. No.1 of specification and scope of work. | 5 | Each | 4,00,000 ₹20,00,000 | 3,33,800 ₹16,69,000 | 2,40,130 ₹12,00,650 Lowest |
| 1.03 | Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing ACB’s & MCCBs
ii) ACB, 4 pole, 630A, 50KA-2 Nos.
iii) MCCB, 3 pole, 400A, 36KA-2 Nos.
iv) MCCB, 3 pole, 160A, 36KA-3 Nos
Panel shall be designed as per Sl. No.1 of specification and scope of work. | 2 | Each | 7,00,000 ₹14,00,000 | 4,48,800 ₹8,97,600 | 3,04,251.2 ₹6,08,502.4 Lowest |
| 1.04 | Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 400A, 36KA-2 Nos.
iii) MCCB, 3 pole, 250A, 36KA-3 Nos. iv.) MCCB, 3 pole, 160A, 36KA-3 Nos.
v) MCCB, 3 pole, 125A, 16KA-7 Nos.
Panel shall be designed as per Sl. No.1 of specification and scope of work. | 7 | Each | 5,75,000 ₹40,25,000 | 5,07,800 ₹35,54,600 | 3,41,893.2 ₹23,93,252.4 Lowest |
| 1.05 | Indoor power panel : Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs )
i) Air circuit breaker 800 amps, 4 pole,50 KA,manual draw out type as Incomer.
Panel shall be designed as per Sl. No.1 of specification and scope of work. | 2 | Each | 1,45,000 ₹2,90,000 | 1,12,800 ₹2,25,600 | 97,350 ₹1,94,700 Lowest |
| 1.06 | Indoor power panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without MCCBs)
i) MCCB, 3 pole,400A, 36 KA as incomer. Panel shall be designed as per Sl. No.1 of specification. | 1 | Each | 75,000 ₹75,000 | 50,800 ₹50,800 Lowest | 64,900 ₹64,900 |
| 1.07 | Indoor power distribution panel : Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (withoutMCCBs)
i)MCCB, 3 pole , 400A ,36 KA as incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole,250A,36KA-01 No. Iii) MCCB, 3 pole, 160A, 36KA-02 Nos.
Iv) MCCB, 3 pole, 125A, 16KA-02 Nos.
Panel shall be designed as per Sl. No.1 of specification. | 3 | Each | 1,50,000 ₹4,50,000 | 1,52,800 ₹4,58,400 | 1,29,800 ₹3,89,400 Lowest |
| 1.08 | Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following(without MCCBs)
i)MCCB, 3 pole , 400A ,36 KA as incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 160A, 36KA-04 Nos.
iii) MCCB, 3 pole, 125A, 16KA-06 Nos. Panel shall be designed as per Sl. No.1 of specification. | 10 | Each | 3,00,000 ₹30,00,000 | 2,66,800 ₹26,68,000 | 2,03,137 ₹20,31,370 Lowest |
| 1.09 | Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs)
i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 400A, 36KA-1 No.
iii) MCCB, 3 pole, 250A, 36KA-2 Nos. iv.) MCCB, 3 pole, 125A, 16KA-7 Nos.
Panel shall be designed as per Sl. No.1 of specification and scope of work | 2 | Each | 4,25,000 ₹8,50,000 | 3,46,800 ₹6,93,600 | 2,42,077 ₹4,84,154 Lowest |
Tender Value
₹2.3 Cr
EMD Value
₹3.0 L
Closing Date
22 Oct 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
THE CHIEF GENERAL MANAGER
ORDNANCE FACTORY MEDAK YEDDUMAILARAM SANGAREDDY 502205
Replacement supply installation and commissioning of LT power distribution panels in HFMD shops(Bldg No 2 and 5) inside the Factory area at OFMK
2024_AVNL_209916_1
76026/TE-09/OFMK/EOC/HFMD LT PANEL/24-25
Open Tender
Civil Works
Item Rate
270 days
ORDNANCE FACTORY MEDAK
AS PER TENDER TERMS AND CONDITIONS
2 documents required · 2 mandatory
₹0
₹3.0 L
29 May 2026
1 Oct 2024
23 Oct 2024
1 Oct 2024
22 Oct 2024
1 Oct 2024
Amount
Supply, Installation & Commissioning of LT power distribution Panel: LT power distribution panel indoor type, front operated, fixed type construction, fully compartmentalized, hinged doors at front and rear with screw type knobs, separate hinged doors for incomer and each individual outgoing feeder. Indoor floor mounted with bus bars access from front and cable termination access from rear side. Cubical type uniform depth throughout the panel. As per attached Annexure-1 for technical specification and scope of work.
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without MCCBs) i)MCCB, 3 pole, 400A, 36 KA as incomer and the following as outgoing MCCBs ii) MCCB, 3 pole, 125A, 16KA-10 Nos Panel shall be designed as per Sl. No.1 of specification.
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 800 amps, 4 pole,50 KA,manual draw out type as Incomer. and the following as outgoing MCCBs ii) MCCB, 3 pole, 250 A, 36KA -2Nos iii) MCCB, 3 pole, 160A, 36KA-4 Nos. iv) MCCB, 3 pole, 125A, 16KA-4 Nos. Panel shall be designed as per Sl. No.1 of specification and scope of work.
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing ACB’s & MCCBs ii) ACB, 4 pole, 630A, 50KA-2 Nos. iii) MCCB, 3 pole, 400A, 36KA-2 Nos. iv) MCCB, 3 pole, 160A, 36KA-3 Nos Panel shall be designed as per Sl. No.1 of specification and scope of work.
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs ii) MCCB, 3 pole, 400A, 36KA-2 Nos. iii) MCCB, 3 pole, 250A, 36KA-3 Nos. iv.) MCCB, 3 pole, 160A, 36KA-3 Nos. v) MCCB, 3 pole, 125A, 16KA-7 Nos. Panel shall be designed as per Sl. No.1 of specification and scope of work.
Indoor power panel : Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs ) i) Air circuit breaker 800 amps, 4 pole,50 KA,manual draw out type as Incomer. Panel shall be designed as per Sl. No.1 of specification and scope of work.
Indoor power panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without MCCBs) i) MCCB, 3 pole,400A, 36 KA as incomer. Panel shall be designed as per Sl. No.1 of specification.
Indoor power distribution panel : Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (withoutMCCBs) i)MCCB, 3 pole , 400A ,36 KA as incomer and the following as outgoing MCCBs ii) MCCB, 3 pole,250A,36KA-01 No. Iii) MCCB, 3 pole, 160A, 36KA-02 Nos. Iv) MCCB, 3 pole, 125A, 16KA-02 Nos. Panel shall be designed as per Sl. No.1 of specification.
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following(without MCCBs) i)MCCB, 3 pole , 400A ,36 KA as incomer and the following as outgoing MCCBs ii) MCCB, 3 pole, 160A, 36KA-04 Nos. iii) MCCB, 3 pole, 125A, 16KA-06 Nos. Panel shall be designed as per Sl. No.1 of specification.
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs ii) MCCB, 3 pole, 400A, 36KA-1 No. iii) MCCB, 3 pole, 250A, 36KA-2 Nos. iv.) MCCB, 3 pole, 125A, 16KA-7 Nos. Panel shall be designed as per Sl. No.1 of specification and scope of work
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs ii) MCCB, 3 pole, 400A, 36KA-2 Nos. iii) MCCB, 3 pole, 250A, 36KA-2 Nos. iv.) MCCB, 3 pole, 160A, 36KA-3 Nos. v) MCCB, 3 pole, 125A, 16KA-3 Nos. Panel shall be designed as per Sl. No.1 of specification and scope of work
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 800 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs ii) MCCB, 3 pole, 400A, 36KA-1 No. iii) MCCB, 3 pole, 250A, 36KA-2 Nos. iv) MCCB, 3 pole, 160A, 36KA-3 Nos. v) MCCB, 3 pole, 125A, 16KA-4 Nos. Panel shall be designed as per Sl. No.1 of specification and scope of work
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole, 50 KA, manual draw out type as Incomer and the following as outgoing ACB’s & MCCBs ii) ACB, 4 pole, 630A, 50KA-1 No. iii) MCCB, 3 pole, 400A, 36KA-2 Nos. iv) MCCB, 3 pole, 250A, 36KA-2 Nos. v) MCCB, 3 pole, 160A, 36KA-3 Nos. vi) MCCB, 3 pole, 125A, 16KA-3 Nos. Panel shall be designed as per Sl. No.1 of specification and scope of work.
Dismantling of Panels: Dismantling of existing Electrical panels including disconnection of cables, glands etc completely and shifting to stores as instructed by EIC.
Air circuit Breaker (ACB): Supply and Fixing of ACB 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 1000 Amps, 50KA breaking capacity with Earth fault, Over load, short circuit protection, shunt trip, Ics=Icu=Icw (1 sec) and auxiliary contacts, LCD Back light Display, Front ON/OFF indication, spring charge/Discharge indication, 3 distinct mechanical positions indication, Make GE /Areva T&D/Schneider/ Siemens/ L&T/ABB The incoming/ outgoing ACBs are to be installed and commissioned in the LT Distribution Panel as mentioned Sl. No.1 of specification and scope of work
Air circuit Breaker (ACB): Supply and Fixing of ACB 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 800 Amps, 50KA breaking capacity with Earth fault, Over load, short circuit protection, shunt trip, Ics=Icu=Icw (1 sec) and auxiliary contacts, LCD Back light Display, Front ON/OFF indication, spring charge/Discharge indication, 3 distinct mechanical positions indication, Make GE/Areva T&D/Schneider/Siemens/L&T/ABB The incoming/outgoing ACBs are to be installed and commissioned in the LT Distribution Panel as mentioned Sl. No.1 of specification and scope of work
Air circuit Breaker (ACB): Supply and Fixing of ACB 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 630 Amps, 50KA breaking capacity with Earth fault, Over load, short circuit protection, shunt trip, Ics=Icu=Icw (1 sec) and auxiliary contacts, LCD Back light Display, Front ON/OFF indication, spring charge/Discharge indication, 3 distinct mechanical positions indication, Make GE/Areva T&D/Schneider/ Siemens/ L&T/ABB The incoming/ outgoing ACBs are to be installed and commissioned in the LT Distribution Panel as mentioned Sl. No.1 of specification and scope of work
Moulded Case circuit Breaker (MCCB): Supply and Fixing of MCCB 3 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA. The Incoming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947. Make: GE/Schneider /Siemens/ L&T/ ABB.
Moulded Case circuit Breaker (MCCB): Supply and Fixing of MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA. The incoming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947. Make:- GE/Schneider /Siemens/ L&T/ ABB.
Moulded Case circuit Breaker (MCCB): Supply and Fixing of MCCB 3 Pole, 415 V, Fixed type, 160 Amps with breaking capacity 36 KA. The Incoming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947. Make:- GE/Schneider /Siemens/ L&T/ ABB.
Moulded Case circuit Breaker (MCCB): Supply and Fixing of MCCB 3 Pole, 415 V, Fixed type, 125 Amps with breaking capacity 16 KA. The Incoming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947. Make:- GE/Schneider /Siemens/ L&T/ ABB.
Earthing: Earthing complete with Galvanised steel earth plate electrode 60x60 cm X 6 mm thick, buries directly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron or steel strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and watchers of GI or steel all as shown in Electrical plate no 3 connected to earth test point as specified or indicated including testing on completion.
Earth continuity conductor: M&L Earth continuity conductor for or main earthing lead fixed to wall on batten or recess chase or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc, as required 25x4 mm GI strip
GI PIPE: Supply and fixing of GI pipe to protect earthing strip 40 mm dia. medium grade complete all as specified and directed
GI PIPE: Supply and fixing of GI pipe to protect earthing strip 20 mm dia. medium grade complete all as specified and directed
Excavation: Excavating in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre depth over areas in Hard/Dense soil getting out complete all as specified and directed.
cement concrete: providing cement concrete cast in situ for each pit chamber slightly rounded or chamfer angles including finishing by using type B1 1:2:4 (20mm graded aggregate complete all as specified by the EIC
precast cement concrete: B1 1:2:4 (20mm graded aggregate) in covers slabs for earth pits with faces complete all as specified and diriected
mild steel bar 8 mm dia. over cut to length, bend to shape for hooking quality conforming to GD 1, IS 432(pt.1) complete all as specified by the EIC
Synthetic painting to plastered surfaces: Surfaces of any description over 10 cm girth or width. Synthetic enamel single coat.
Writing letters or figures (Block, Roman, italic or Indian) n exc 30cm high
JITENDRA ELECTRICALS (BID ID -759041)
R Pandurangam and sons (BID ID -757654)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.82 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 6.22 MB
Tendernotice_2.pdf
PDF • 0.44 MB
Tendernotice_3.pdf
PDF • 0.72 MB
Tendernotice_4.pdf
PDF • 0.34 MB
Tendernotice_5.pdf
PDF • 0.36 MB
Tendernotice_6.pdf
PDF • 6.30 MB
Tendernotice_7.pdf
PDF • 0.35 MB
Tendernotice_8.pdf
PDF • 0.35 MB
Tendernotice_9.pdf
PDF • 0.07 MB
Tendernotice_10.pdf
PDF • 0.67 MB
Tendernotice_11.pdf
PDF • 0.06 MB
Tendernotice_12.pdf
PDF • 0.38 MB
Tendernotice_13.pdf
PDF • 0.09 MB
BOQ_229614.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .