Loading…
Loading…
Tender Value
₹18.2 L
EMD Value
₹50,000
Closing Date
22 Jul 2026, 4:30 pmClosed
UNIT HEAD
KEL EDARIKODE
Thalassery Municipality Project No SO 251/26-Installation of Solar Panel at New Municipal office
2026_KEL_860723_1
KEL/ KEMG/72/2026-27
Open Tender
Electrical Works
Item Rate
KEL EDARIKODE
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,299
₹50,000
Yes
28 Jul 2026
15 Jul 2026
23 Jul 2026
15 Jul 2026
22 Jul 2026
15 Jul 2026
15 Jul 2026 - 22 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1APP A: Installation of Solar Panel | |||||
| 1.01 | OD56224/2026-2027
Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of
200-1000 V DC Input voltage range or nearest range and 400V AC, three phase, 4
wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency
not less than 97%, total harmonic distortion less than 3% and suitable for ambient
temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency
level to suit the Grid Voltage Frequency and adustiable for connecting time to gridas
per KSEB norms, including Data Monitoring System complete with accessories
wifi/LAN connecting and connected application software etc. fixing on wall using
wall brackets and giving all connection as required . | - | kW | - | - |
| 1.02 | OD56235/2026-2027
Supply and providing Solar Photovoltaic Module Mono Perc Half Cut / Bi facial
Mono Perc Half Cut of capacity 540 Wp or nearest size, manufactured in India,
conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar
Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules
used in solar power plants/ systems must be warranted for their output peak watt
capacity, which should not be less than 90% at the end of 10 years and 80% at the end
of 25 years. fixing on existing steel frame work using nut bolts/screws etc in suitable
direction at site condition and giving connection and inter connection wire tied using
suitable steel wire tie as per the system string design and direction of department staff | - | each | - | - |
| 1.03 | OD56225/2026-2027
Supply and providing wall mounted AC DB for on grid solar system for connecting
Inverter AC side consists of a). Poly carbonate Enclosure IP65 protection with
transparent front cover with hinged door and termination arrangement, b). SPD
Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection using
suitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection and
DB fixing on wall using suitable screws and plugs etc as required | - | each | - | - |
| 1.04 | OD56229/2026-2027
Supply and providing wall mounted DC DB for on grid solar system for connecting 2 Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65 protection with transparent front cover with hinged/screws door and termination arrangement, b). 2set 20A DC Fuse and Holder for +ve and connector for -ve incomer
side, c). 2set SPD 1000V DC Up1.9kV,Ucpv 585 VDC, In 15kA, Imax 40kA and giving internal connection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitable screws and plugs etc as required | - | each | - | - |
| 1.05 | OD56221/2026-2027
Supplying and drawing 1 run x 4 sq. mm PVC insulated tinned copper conductor,
single core Solar DC cable in the existing surface / recessed steel/ PVC conduit as
required. | - | metre | - | - |
| 1.06 | OD56238/2026-2027
Supply and crimping the Male Female MC4 Solar Panel cable connector including
crimping and connecting etc as required. | - | each | - | - |
| 1.07 | OD56232/2026-2027
Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board and
to fix KSEB meters, fuse units etc as required including fixing it on wall, making
good the damages colour washing etc. as required. | - | each | - | - |
| 1.08 | OD56222/2026-2027
Providing and fixing following capacity TP and N Isolator unit inside the existing
panel board with ISI marked HRC fuses including drilling holes in cubicle panel,
making connections, etc. as required.63 Amp | - | each | - | - |
| 1.09 | 2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps | - | each | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
BOQ_1455546.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .