| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.8 LAdmitted-Finance MADINA COLONY ALOCHI BAGH SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L1 | Admitted-Finance | |
| 2 | L2₹64.5 L+₹1.7 L (2.63%)Admitted-Finance GROUND FLOOR ASHFAQ HUSSAIN AL ABASS A S RELIEF TRUST BUILDING KARAN NAGAR SRINAGAR 91495 SRINAGAR JAMMU AND KASHMIR 190010 | SRINAGAR | JAMMU AND KASHMIR | 190010 | L2 | Admitted-Finance | |
| 3 | L3₹64.9 L+₹2.1 L (3.32%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical 0 S F ENTERPRISES CHANDAK CHANDAK POONCH POONCH JAMMU KASHMIR 185101 UDYAM JK 14 0008974 | POONCH | JAMMU AND KASHMIR | 185101 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S HIGHLAND ENGINEERING L3 | marib constructions L2 | M/s PRESTIGE L1 |
|---|---|---|---|---|---|---|
| 1.00SITC of | ||||||
| 1.01 | 11/0.433kV, 400 KVA 3-phase Distribution transformei
with Eimetalllc Terminal Connectors Energy tevel,
2, Copper wound, and with LV
Cable gox having detachable Aluminium Gland
plate,
.Transformer should have arrangement for vertica take off | 1 | No | 14,00,000 ₹14,00,000 Lowest | 21,69,480 ₹21,69,480 | 18,00,000 ₹18,00,000 |
| 1.02 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 1 | Set | 10,000 ₹10,000 Lowest | 15,000 ₹15,000 | 10,000 ₹10,000 Lowest |
| 1.03 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type | 1 | Set | 20,000 ₹20,000 | 25,000 ₹25,000 | 18,500 ₹18,500 Lowest |
| 1.04 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | 3,000 ₹3,000 Lowest | 15,000 ₹15,000 | 10,000 ₹10,000 |
| 1.05 | 95 mm² Single Core ,1.1kV Grade, PVC Insulated Stranded ConductorFRLS type | 88 | Mtr | 400 ₹35,200 | 1,250 ₹1,10,000 | 150 ₹13,200 Lowest |
| 1.06 | 9 Mtr. Long Pole,ST-410 SP33) | 4 | Nos | 28,000 ₹1,12,000 Lowest | 35,000 ₹1,40,000 | 30,000 ₹1,20,000 |
| 1.07 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm | 6 | Nos | 1,000 ₹6,000 | 950 ₹5,700 Lowest | 1,500 ₹9,000 |
| 1.08 | GI Channel/Angle/Flat of sizes including clamps | 600 | Kgs | 500 ₹3,00,000 | 250 ₹1,50,000 | 50 ₹30,000 Lowest |
| 1.09 | Galvinized Nuts and Bolts. | 16 | Kgs | 200 ₹3,200 Lowest | 350 ₹5,600 | 250 ₹4,000 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
10 Jul 2025, 1:00 pmClosed
Executive Engineer
Electric Distribution Division kargil
Supply, Installation, testing and Commissioning for Creation of 400 KVA sub- stations along with HT/LT network at Industrial estate Zanskar
2025_PDNRE_16694_1
E NIT 42 OF 2025-26
Open Tender
Electrical Works
Turn-key
60 days
Zanskar
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Account No 0096010200000064 IFSC Code JAKA0KARGIL)
₹1.3 L
17 Jul 2025
28 Jun 2025
11 Jul 2025
28 Jun 2025
10 Jul 2025
6 Jul 2025
Amount
SITC of
11/0.433kV, 400 KVA 3-phase Distribution transformei with Eimetalllc Terminal Connectors Energy tevel, 2, Copper wound, and with LV Cable gox having detachable Aluminium Gland plate, .Transformer should have arrangement for vertica take off
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
95 mm² Single Core ,1.1kV Grade, PVC Insulated Stranded ConductorFRLS type
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Chemical Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
LT Distribution Box for 400 KVA Sub- Station With MCCB and SFUs for outgoing
Wedge connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like almunium lugs,jumpers,binding tape etc
9 Mtr. Long Pole (ST-410 SP33)
GI V Cross-arm with Top Bracket (including clamps/GI Channel X-arm)
30 mm² ACSR Conductor
PG Clamps for 30 mm² ACSR Conductor
33kV Polymeric Composite Pin Insulator (36kV, 170kV Impulse, 900mm creepage)
33kV Polymeric Composite Disc Insulator (70kN, 170kV Impulse, 900mm creepage)
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete (GI Pipe 40mm, 3m long + GI Strip 25x3mm)
Red Oxide
Aluminium Paint
Cement Bottoming (1:2:4 mix as per REC standards - 5cum/pole)
8 Mtr. Long Pole
120 mm² AB (LT) Cable (3X120+1X16+1X70 mm² XLPE)
Suspension/Tension Clamps (Complete Set)
Straight-through Cable Joining Kit
Galvanized Nuts and Bolts
SMDB with MCCB & Connectors for Outgoing Connections
Insulating Piercing Connectors
Earthing Complete (GI Pipe 40mm, 3m long + GI Strip 25x3mm)
Red Oxide
Aluminium Paint
Danger Plates
Cement Bottoming (1:2:4 mix as per REC standards -.45cum/pole)
SITC of Tri- Vector Energy meter oil emersed pole mounted with suitable CT/PT for 400 KVA DTR
marib constructions (BID ID -163123)
M/S HIGHLAND ENGINEERING (BID ID -163089)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .