Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.3 L+₹1.6 L (13.8%)Rejected-Finance MAHALAKPUR NIZAMPUR AGHWANPUR ROAD AGHWANPUR MORADABAD UTTAR PRADESH 244001 | MORADABAD | UTTAR PRADESH | 244001 | L2 | Rejected-Finance Being L2 other than lowest bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to not in requisite category |
Tender Value
₹13.6 L
EMD Value
₹27,000
Closing Date
7 Jan 2020, 6:00 pmClosed
GE(N) Tezpur
GE(N) TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
SPL REPAIR OF INTERNAL WIRING WITH ACCESSORIES AND FITTING COMPLETE IN OTM ACCN BLDG NO T-39, T-9 AND T-5/7 AND CERTAIN REV/MINOR WORKS AT NAA UNDER GE (NORTH) TEZPUR
2019_MES_278526_1
GE(N)/TEZ/2019-20/8360
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE(N) Tezpur
as per tender docs
8 documents required · 8 mandatory
₹500
GE(N) Tezpur
₹27,000
Yes
15 Feb 2020
25 Nov 2019
8 Jan 2020
25 Nov 2019
7 Jan 2020
9 Dec 2019
Amount
Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point or buzzer controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket, light fitting etc; for credit and making good disturbed surfaces of walls, ceilings etc complete all as specified and directed.
Taking down main switches and DBs of any type and make including wooden board / junction box complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm PVC insulated FRLSH unsheathed multi stranded copper conductor cable 1100 Volts grade single core conforming to IS-694-1990 and one run of continous earth wire with 1.50 Sqmm stranded core PVC insulated unsheathed copper conductor cable draw in & including PVC surface casing ‘N’ capping 20mm or more than 20mm wide double lock type to be fixed with the help of rawal plugs & screws including necessary fittings & fixtures and including PVC terminal box and PVC board making good disturbed surface with CM (1:4) complete all as specified and directed to match with the existing surface for the following:-
(a) One light/fan/bell/exhaust fan point controlled by one, one way switch, with cable 1.5 sqmm
(b) All as per item No 3 here-in- before but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable.
(c) All as per item No. 3 here-in- before but for 3 pin 15 Amps switch socket combination on independent board with 2.5 sq mm copper cable
(d) All as per item No 3 here -in -before but for 5 Amps socket point on the same board controlled by one switch.
S&F for switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed.
S&F for switch socket out let 2 in one, 5 Amps, 240 Volts flush type, complete all as specified and directed.
S&F socket out let only, 5 pin 5 Amps flush type controlled by another 5 Amps complete all as specified and directed.
S&F for switch socket combination 2 in One , 6 pin 5 Amps & 15 Amps flush type complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type for bracket fittings complete all as specified and directed.
S&F ceiling rose surface backelite Polycarbonate type two to three terminals complete all as specified and directed.
S&F stepped type electronic fan regulator complete all as specified and directed.
S&F fan hook made out of MS round bars of 20mm dia cut to size and made to shape hanging from roof supporting bars to the required lenght up to the ceiling level complete all as specified and directed.
S&F for sheet metal enclosure for DBs SPN 8 way with rated bus bar, 240 V, Double door, complete flush mounted complete all as specified and directed.
S&F for SP MCB single pole 240 volts 5 to 32 Amps.B Curve complete all as specified and directed.
S&F Isolator SPN (MCB single pole & neutral) 240 volts 5/6 to 32 Amps complete all as specified and directed..
S & F 1 x 10 W retrofit LED lamp complete all as specified and directed. Make: Wipro/Phillips/Jaquar/GE
S&F LED luminaires, 20 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, wit high transmissivity diffuser, high lumen output, with suitable electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of size 23/0.0076, from conector and ceiling rose complete all as specified and directed. Make: Wipro/Phillips/Jaquar/GE
S&F LED wall security lights 25W with necessary brackets (made out of 25mm bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls complete all as specified and directed. Make: Wipro/Phillips/Jaquar/GE
S&F LED recess mounted (2'x2' size flat panel) luminaire which provide soft light and glare free symmertical illumination of size 36 W,(Lumen output not lessthan 3600) complete all as specified and directed. Make: Wipro/Phillips/Jaquar/GE
Excavation in trenches, in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth loose soil and getting out for removing/laying of cable complete all as specified and directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick all as complete all as specified and directed.
Removing of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for Sand Cushioning using clean,dry angular sand completely free from organic and other harmful matters in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 cm (8 Cm in depth before laying the Cable and 15 Cm after laying the Cable) and consolidated (punned) upto 18cm thickness, complete all as specified and as directed. NOTE : Punned thickness of Sand Cushioning shall only be measured and consider for payment.
M&L for bricks sub-class 'B' laid in trenches with width equal to width of the brick for the protection of under ground cable complete all as specified and directed.
Supply, laying, jointing and testing LT cable in trenches or on poles/walls, XLPE insulated screened, PVC bedded, galvanized steel strip or wire armored , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm, 2 core complete all as specified and directed.
S&F GI Pipe light grade 40 mm dia, ISI marked, of required length for protection of cables in wall /pole /under road complete including necessary MS clamps, nuts, bolts and washers etccomplete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point all as specified or indicated including excavation and connected earth work, in soft/loose soil, removing soil upto 50m, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40mm bore GI medium grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 10cm C/C both ways and with handle made out of 20mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt and testing on completion complete all as specified and directed.
Supply, install, conection testing of storage type Electric Geyser (water Heater) of capacity 25 Ltr, ( 5 Star rated) with high density insulation including four numbers fastener bolt with nuts and washers,complete all as specified and directed. Make-Jaquar Model ELEENA or Equivalent from approved makes
M&L for point wiring with 2.5 sqmm (nominal area) FRLS PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade of size not less than 20 mm dia concealed in wall, pressed steel concealed terminal boxes of required size and with top cover 3 mm thick of plastic laminated sheet of reqd colour, painting terminal boxes inside and out side with one coat red oxide primer complete with all accessories and all as specified including 2.5 Sqmm FRLS PVC insulated sheathed multistranded copper earth conductor to common earth and connected to earth dolly for one power point controlled by one switch complete all as specified and directed.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 10 KA, 'C' Curve complete all as specified and directed.
M&L for mild steel galvanised Tubes (Medium grade) of 20 mm dia with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for mild steel galvanised Tubes (Medium grade) of 15 mm dia with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F 15mm dia Bib taps, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, fancy type chromimum plated complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
M&L for Gun-metal, globe or gate valves,of 20 mm dia with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
M&L for cutting/ inserting tees etc for taking branch connection complete all as specified and directed.
M&L for Chemical earthing with copper earth plate 90cmx60cmx5mm & copper earth strip 32x6mm complete with, 2.5 metres length,buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level complete with test point complete all as specified and directed. Make: Make: JMV LPS Limited/ Uni earth & HPS Power & earthing solution. Note : Copper strip rod and plate shall be 99.9% pure. After completion earth resistance shall be measured and test certificate shall be submitted. earth resistance value of individual earth pit should be less than 1 Ohm. Complete Layout with dimension of the eathing shall be submitted by contractor after commisioning. Warranty shall be 60 months from the date of commisioning.
M&L for earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc with earth strip of size 20x3mm complete all as specified and directed.
S&F Exhaust Fan 450mm sweep, 900RPM ,with metal blade and louver complete fixed in wall with fastener and including making hole in wall of suitable size and plastering finishing of surfaces complete all as specified and directed. Make: Usha Model Turbo HD/ bajaj/Crompton Greaves.
S&F ceiling fans complete with accessories 230 V,1200 mm sweep. 5 star rated, including providing three core, flexible copper conductor wire of size 23/0.0076 from ceiling rose to fan complete all as specified and directed. Make: Usha/ bajaj/Crompton Greaves.
S&F Exhaust Fan 230mm sweep ,with metal blade and louver complete fixed in wall with fastener and including making hole in wall of suitable size and plastering finishing of surfaces complete all as specified and directed. Make: Usha Model Turbo jet DBB-LD/bajaj/Crompton Greaves.
Supply & erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug,as specified of type 410 SP- 31 (Overall length 9 meter) including necessary excavation and earth work, PCC (1:4:8) type D-2 in base (60 x 60 x 10 cm) and foundation (50 x 50 x 140 cm) and coping (50 x 50 x 30 cm) with (1:3:6) type C-1 includingnecessary form work up to 30 cms above ground level, including taking down old poles and numbering of poles complete all as specified and directed. Note:- . All pole shall be painted with two coats of synthetic enamel paint through out above Ground level with black and white coloured painted strip in layers or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of poles
Supply, laying, jointing and testing LT cable, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core for laying in trenches and poles /walls complete all as specified and directed.
M&L for Thermoplastic Cable Junction Boxes IP66/67 "weather proof" , for outdoor installation with knockouts for cable entry with terminals suitable for 10-16 sqmm cable of size 155 X 210 X 92 mm including busbar mounted on insulator and MCB SP 6 Amps-1 No, including Necessary civil works and connecting all incoming and outgoing wires with aluminium lugs of appropiate sizes complete all as specified and directed. Make Hansel Cat No. KF1616G or equivalent from approved makes
S&F LED street light fitting 30Watts, made of pressure die-cast aluminium housing with toughned glass and high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 with electronic driver and SPD etc, and including its onnection with 3 core 1.5 sqmm stranded PVC Insulated and PVC Sheathed copper Conductor wire from Junction Box to street light fitting including providing mounting bracket made out of 25 mm dia GI Pipe medium grade 1.2m long cut to size and bend to shape ( 01 No) fixing on poles with flat iron clamps 25mm X3mm -02 Sets with nut bolts and washers duly painting with two coat of aluminium paint over a coat of red oxide primer for GI pipe and clamps etc, complete all as specified and directed.
Supply, installation and comissioning of wall split AC unit indoor/outdoor complete with cordless remote control unit and with in built air ioniser and filter for better indoor air quality of single phase of capacity of 1.0 TR, BEE 5 star rated driven duly filled by NON CFC and complete with all accessories 240Volts, 50 Hz complete all as specified and directed. Note-Contractor shall give one year service warranty on AC unit and 5 year on compressor.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% , 12 A and of capacity 2.0 KVA with digital Amps/Voltmeter including electric connection from sources complete all as specified and directed. Make : V Guard/Microtek/APC
M&L for submain wiring with two single core 4 sq mm FRLS PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduit including 6 sq mm multi-strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete all as specified and directed.
M/S Bharat Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .