Office of SE,SWEC,PWD, MIDNAPORE
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Supply, Installation, Testing, and Commissioning of 250 KVA DG set at Academic Building-II , SKBU , Purulia in the District of Purulia---Electrical Installation works for Installation of Diesel Generator Sets
2020_WBPWD_308972_5
WBPWD/SE/SWEC/NIQ31/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
PURULIA
Please refer Tender documents.
3 documents required · 3 mandatory
₹29,692
Office of SE / SWEC, PWD, Midnapore
20 Jul 2022
9 Aug 2021
25 Aug 2021
9 Aug 2021
23 Aug 2021
12 Aug 2021
11 Aug 2021
Amount
Supply of 1.1 KV grade XLPE insulated armoured cable with aluminium conductor (Make-Havells/RR Kabel/Gloster/Ploycab) as per direction of EIC
3 ½ Core 400 sqmm
Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of one cable above 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand.
S&F 100 mm dia. Medium gauge GI Pipe (ISI-Medium) protection with necy. fitting and jointing material as required.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
3 ½ Core 400 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
3 ½ Core400 sqmm
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts.long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts (1 nos 250 KVA DG earthing body-2 nos, Neutral-2 nos,)
Excavation of soil for installation of Earth Electrode and filling & ramming. [For Morrum Soil] @1.75cubic mtr/earth.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Treatment of soil by using salt & charcoal for pipe electrode (morrum soil).
Extra for connecting the neutral of Transformer/Earth busbar to earth electrode including S & F Galvanized (Hot Dip) Steel strip 65 mm x 8 mm on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
S&F Exhaust gas pipe of 150 mm dia exhaust pipe made up of 20 SWG GI sheet cut to required lengths provided with flenge on both side of each peice having thin copper gasket installed with necessary bends, supports and clamp, anti- vibration mounting, insulation of exhaust system with mineral wool/Rockwool, 50 mm thick wire mesh & aluminium cladding etc. as required as per specification incl S & F rain protection canopy..
Supply and drawing 1.1KV 1x 95 sq. mm single core stranded ‘FR’ PVC insulated copper wire in PVC rigid conduit incl. necy. fitting as required embedding in wall /floor from neutral earth bus to generator neutral incl. both side socketing and necy. connection. [Polycab/Gloster/RR Kabel]
Supply and laying 14 core x 2.5 sq. mm PVC insulated armoured cable with copper conductor embedded in floor with necy connection. [Polycab/Gloster/RR Kabel]
Supply and pouring High speed Diesel oil for starting and commissioning of DG set
Supply and pouring Mobile oil (CH415W40)
Supply and delivery of 200 ltrs capacity barrel made of heavy gauge MS sheet with High speed Diesel oil
Supply and delivery of best quality oil hand pump with 25 mm dia PVC flexible pipe of 6 mtr length. [Make- JAIN TECH, 3.5mtr head, capacity-3ltr. M. S. Body]
Supply & installation of CPRI approved cubicle type compartmentalised wall cum floor mounted LT panel board of suitable size and shape for existing panel room and made of 2mm thick CRCA sheet, angle/ flat iron for structural frame work & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint having copper Bus-bar and following equipment & accessories. Protection required of panel is IP-54.
Bus-bar: 415V 800A Horizontal Bus-bar system with EPR support for main power distribution by S&F electrolyte tinned copper bar.To supply power to individual section from Bus-bar with suitable size copper bar/ wire with socketing, all joint must be of bolted type construction. Proper colour code to be provided by PVC heat shrink sleeves.
Incoming: a)630A 415V TPN SDF unit (L&T make Cat no. SK95521 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no.
Outgoing:a) 100A 415V TPN SDF unit (open execution) (L&T make Cat no. SK95568 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 13 nos b) 250A 415V TPN SDF unit (L&T make Cat no. SK95642 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no
Constructional Details: The panel to be made by 2mm thick CRCA sheet. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from bottom of the panel and it should be compartmentalized. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. Cable chamber in the panel shall be 600mm width along the vertical. The panel shall have suitable size integral and removable lifting lug in required nos. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted. The material and design should be approved by EIC before fabrication.
Metering & Indication arrangement: a) LED Multifunction Meter (L&T Cat no. WL440010OOOO or eqv make of Schneider /Siemens) – 1 no. b) 630/5A CT (Kappa make) -3 nos. c) LED indicating lamp (Siemens make /Esbee make) – 3 nos. d)16A TPMCB-1 no. e) EI danger board – 1 no. All wiring for metering & indication to be done with 1.1KV grade PVC insulated stranded FR copper wire of size 1.5 sq mm, each wire shall have ferrules & lugs at both end. Metering & indication wires shall be nearly bunched separately and adequately supported so as to prevent stress and strain on termination. The material and design should be approved by EIC before fabrication.
SITC of CPRI approved cubicle type compartmentalised floor mounted LT panel board of suitable size and shape for existing panel room and made of 2mm thick CRCA sheet steel CNC fabricated panel & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint (RAL 7032) having electrolytic tinned copper Bus-bar and following equipment & accessories. Protection rank required of panel is IP-54.
Bus-bar: 415V 800A Horizontal Bus-bar system with EPR support for main power distribution by S&F electrolyte tinned copper bar.To supply power to individual section from Bus-bar with suitable size copper bar/ wire with socketing, all joint must be of bolted type construction. Proper colour code to be provided by PVC heat shrink sleeves.
Incoming: a)630A 415V TPN SDF unit (L&T make Cat no. SK95521 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no.
Outgoing:a) 100A 415V TPN SDF unit (open execution) (L&T make Cat no. SK95568 or Eqv. Make of Siemens / Schneider ) with 3 nos. of HRC fuse – 16 nos b) 315A 415V TPN SDF unit (L&T make Cat no. SK95461 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no
Constructional Details:The panel to be made by 2mm thick CRCA sheet. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from bottom/top of the panel. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. Cable chamber in the panel shall be 200mm width along the horizontal. The panel shall have suitable size integral and removable lifting lug in required nos. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted.
Metering & Indication arrangement: a) LED Multifunction Meter (L&T Cat no. WL440010OOOO or eqv make of Schneider /Siemens) – 1 no. b) 630/5A CT (Kappa make) -3 nos. c) LED indicating lamp (Siemens make /Esbee make) – 3 nos. d)16A TPMCB-1 no. e) EI danger board – 1 no. All wiring for metering & indication to be done with 1.1KV grade PVC insulated stranded FR copper wire of size 1.5 sq mm, each wire shall have ferrules & lugs at both end. Metering & indication wires shall be nearly bunched separately and adequately supported so as to prevent stress and strain on termination. The material and design should be approved by EIC before fabrication.
Supply & installation of CPRI approved cubicle type compartmentalised wall cum floor mounted LT panel board of suitable size and shape for existing panel room and made of 2mm thick CRCA sheet, angle/ flat iron for structural frame work & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint having copper Bus-bar and following equipment & accessories. Protection required of panel is IP-54.
Bus-bar: 415V 630 A Horizontal Bus-bar system with EPR support for main power distribution by S&F electrolyte tinned copper bar.To supply power to individual section from Bus-bar with suitable size copper bar/ wire with socketing, all joint must be of bolted type construction. Proper colour code to be provided by PVC heat shrink sleeves.
Incoming:-a) 400A 415V TPN SDF unit (L&T make Cat no. SK9521 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no.
Outgoing:-a) 100A 415V TPN SDF unit (open execution) (L&T make Cat no. SK95568 or Eqv. Make of Siemens / Schneider ) with 3 nos. of HRC fuse – 13 nos b) 250A 415V 4P Change over switch (L&T make Cat no.CO32500OOOO or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no
Constructional Details:-The panel to be made by 2mm thick CRCA sheet. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from bottom/top of the panel. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. Cable chamber in the panel shall be 200mm width along the horizontal. The panel shall have suitable size integral and removable lifting lug in required nos. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted.
Metering & Indication arrangement: a) LED Multifunction Meter (L&T Cat no. WL440010OOOO or eqv make of Schneider /Siemens) – 1 no. b) 400/5A CT (Kappa make) -3 nos. c) LED indicating lamp (Siemens make /Esbee make) – 3 nos. d)16A TPMCB-1 no. e) EI danger board – 1 no. All wiring for metering & indication to be done with 1.1KV grade PVC insulated stranded FR copper wire of size 1.5 sq mm, each wire shall have ferrules & lugs at both end. Metering & indication wires shall be nearly bunched separately and adequately supported so as to prevent stress and strain on termination. The material and design should be approved by EIC before fabrication.
SITC of CPRI approved cubicle type compartmentalised floor mounted LT panel board of suitable size and shape for existing panel room and made of 2mm thick CRCA sheet steel CNC fabricated panel & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint (RAL 7032) having electrolytic tinned copper Bus-bar and following equipment & accessories. Protection rank required of panel is IP-54.
Bus-bar: 415V 400A Horizontal Bus-bar system with EPR support for main power distribution by S&F electrolyte tinned copper bar.To supply power to individual section from Bus-bar with suitable size copper bar/ wire with socketing, all joint must be of bolted type construction. Proper colour code to be provided by PVC heat shrink sleeves.
Incoming:-a) 315A 415V TPN SDF unit (L&T make Cat no. SK95521 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no.
Outgoing:-a) 100A 415V TPN SDF unit (open execution) (L&T make Cat no. SK95568 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 16 nos c) 315A 415V 4P Change over switch (L&T make Cat no. CO33150OOOO or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no
Constructional Details:-The panel to be made by 2mm thick CRCA sheet. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from bottom/top of the panel. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. Cable chamber in the panel shall be 200mm width along the horizontal. The panel shall have suitable size integral and removable lifting lug in required nos. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted.
Metering & Indication arrangement: a) LED Multifunction Meter (L&T Cat no. WL440010OOOO or eqv make of Schneider /Siemens) – 1 no. b) 315/5A CT (Kappa make) -3 nos. c) LED indicating lamp (Siemens make /Esbee make) – 3 nos. d)16A TPMCB-1 no. e) EI danger board – 1 no. All wiring for metering & indication to be done with 1.1KV grade PVC insulated stranded FR copper wire of size 1.5 sq mm, each wire shall have ferrules & lugs at both end. Metering & indication wires shall be nearly bunched separately and adequately supported so as to prevent stress and strain on termination. The material and design should be approved by EIC before fabrication.
SITC of CPRI approved cubicle type compartmentalised floor mounted LT panel board of suitable size and shape for existing panel room and made of 2mm thick CRCA sheet steel CNC fabricated panel & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint (RAL 7032) having electrolytic tinned copper Bus-bar and following equipment & accessories. Protection rank required of panel is IP-54.
Bus-bar: 415V 400A Horizontal Bus-bar system with EPR support for main power distribution by S&F electrolyte tinned copper bar.To supply power to individual section from Bus-bar with suitable size copper bar/ wire with socketing, all joint must be of bolted type construction. Proper colour code to be provided by PVC heat shrink sleeves.
Incoming:-a) 315A 415V TPN SDF unit (L&T make Cat no. SK95521 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no.
Outgoing:-a) 100A 415V TPN SDF unit (open execution) (L&T make Cat no. SK95568 or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 16 nos c) 315A 415V 4P Change over switch (L&T make Cat no. CO33150OOOO or Eqv. Make of Siemens / Schneider) with 3 nos. of HRC fuse – 1 no
Constructional Details:-The panel to be made by 2mm thick CRCA sheet. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from bottom/top of the panel. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. Cable chamber in the panel shall be 200mm width along the horizontal. The panel shall have suitable size integral and removable lifting lug in required nos. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted.
Metering & Indication arrangement: a) LED Multifunction Meter (L&T Cat no. WL440010OOOO or eqv make of Schneider /Siemens) – 1 no. b) 315/5A CT (Kappa make) -3 nos. c) LED indicating lamp (Siemens make /Esbee make) – 3 nos. d)16A TPMCB-1 no. e) EI danger board – 1 no. All wiring for metering & indication to be done with 1.1KV grade PVC insulated stranded FR copper wire of size 1.5 sq mm, each wire shall have ferrules & lugs at both end. Metering & indication wires shall be nearly bunched separately and adequately supported so as to prevent stress and strain on termination. The material and design should be approved by EIC before fabrication.
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, surface on wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.6 way Enclosure (Legrand / Siemens/Schneider)
Supplying and fixing 63A FP 415 V MCB Isolator on din rail of existing DBs and necessary connection (Legrand / Siemens/Schneider)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection-32 Amp SPMCB.(Legrand / Siemens/Schneider)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy.fittings as required.2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
SREE LALJI
MOON LIGHT HOUSE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .