| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAdmitted-Finance CC 1 BOOTH NO 8 JANTA BHAWAN ROAD SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | ₹1.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹2.4 L (1.36%)Admitted-Finance OM VIHAR COLONY DELHI ROAD ROORKEE | ₹1.8 Cr+₹2.4 L (1.36%) | L2 | Admitted-Finance |
| 3 | L3₹1.8 Cr+₹3.6 L (2.04%)Admitted-Finance HARIDWAR | ₹1.8 Cr+₹3.6 L (2.04%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ASHOK KUMAR AND CO L1 | RAVI CONSTRUCTION CO L2 | Sagar Engineering Company L3 |
|---|---|---|---|---|---|---|
| 1.00Supply ( Annexure -I) | ||||||
| 1.01 | P.C.C. Pole ( 8.5 Mtr. Long )( As per specification) | 220 | Nos. | - | - | - |
| 1.02 | L.T. A.B. Cable size 3x95+1x70sq.mm ( As per specification) | 29.55 | KM. | - | - | - |
| 1.03 | L.T. P.V.C. Cable (1x25sq.mm) for D.Box. | 5,800 | Mtr. | - | - | - |
| 1.04 | L.T. P.V.C. Cable (2x6sq.mm) for Consumer connection. | 5,000 | Mtr. | - | - | - |
| 1.05 | Galvanised Stay Set 16x1800 sq.mm. including 7/10swg. Stay wire binding,nozzling of stay complete work. The minimim guarantee of finished 16x1800sq.mm. stay sets shall be 5.8 Kg. equivalent ISS as per drawing & specification for supporting poles of overhead line . | 125 | Nos. | - | - | - |
| 1.06 | Supply of Stay wire as per specification. | 625 | Kg. | - | - | - |
| 1.07 | Supply of Dead End Clamps with I Hook. ( As per drawing attached ) & as per UPCL specification. | 780 | Nos. | - | - | - |
| 1.08 | Supply of SMC 3 Phase L.T. Distribution Box, .Al.Bus bar RYB 25x6mm.Al. Busbar N. 40x6mm. ISO reputed company with Clamps with Nut & bolts. ( As per drawing attached )& as per UPCL specification. | 725 | Nos. | - | - | - |
| 1.09 | Supply of Suspension Clamp with I hook.with Nut & bolts. ( As per drawing attached )& as per UPCL specification. | 615 | Nos. | - | - | - |
Tender Value
₹2.4 Cr
EMD Value
₹3.6 L
Closing Date
11 Jun 2020, 3:00 pmClosed
Superintending Engineer
SE,EDC,Rudrapur.
Replacement of bare conductor by AB Cable under 33/11KV. Sub station, Chorgalia feeder.
2020_UPCL3_23747_1
EDC(USN)02/2020-21
Open Tender
Electrical Works
Item Rate
180 days
Sitarganj
Pl. refer tender documents.
3 documents required · 3 mandatory
₹11,800
SE,EDC,Rudrapur.
₹3.6 L
25 Jun 2020
20 May 2020
12 Jun 2020
21 May 2020
11 Jun 2020
21 May 2020
Amount
Supply ( Annexure -I)
P.C.C. Pole ( 8.5 Mtr. Long )( As per specification)
L.T. A.B. Cable size 3x95+1x70sq.mm ( As per specification)
L.T. P.V.C. Cable (1x25sq.mm) for D.Box.
L.T. P.V.C. Cable (2x6sq.mm) for Consumer connection.
Galvanised Stay Set 16x1800 sq.mm. including 7/10swg. Stay wire binding,nozzling of stay complete work. The minimim guarantee of finished 16x1800sq.mm. stay sets shall be 5.8 Kg. equivalent ISS as per drawing & specification for supporting poles of overhead line .
Supply of Stay wire as per specification.
Supply of Dead End Clamps with I Hook. ( As per drawing attached ) & as per UPCL specification.
Supply of SMC 3 Phase L.T. Distribution Box, .Al.Bus bar RYB 25x6mm.Al. Busbar N. 40x6mm. ISO reputed company with Clamps with Nut & bolts. ( As per drawing attached )& as per UPCL specification.
Supply of Suspension Clamp with I hook.with Nut & bolts. ( As per drawing attached )& as per UPCL specification.
Supply of M.S. Clamps made of M.S. Flat for P.C.C. Pole 8.5 Mtr. Of size 35x5sq.mm. duly red oxide painted with suitable size with fitted Nut and bols ans washer for M.S. Half C,aip for L.T. Distributyuon As per specirication of UPCL.
Supply of Nut,bolt and washer for Dead End Clamps as per specification of UPCL.
Supply of M.S. Clamps made of M.S. Flat for P.C.C. Pole 8.5 Mtr. Of size 50x6sq.mm. duly red oxide painted with suitable size with fitted Nut and bols ans washer for Suspension as per As per specirication of UPCL.
Supply of Stay Clamps made of M.S. Flat for P.C.C. Pole 8.5 Mtr. Of size 50x6sq.mm. duly red oxide painted with suitable size with fitted Nut and bols ans washer for Suspension as per As per specirication of UPCL.
Supply of insulation peering connectors body molded from high quality mechanical climate and UV resistant glass reinforcd polyamide, hot dipped galvanized bolts & contact teeth RPG/3M make. Suitable for jumpering for Line to Line Jumpering/tapping size 95 to 95sq,mm.
Supply of insulation peering connectors body molded from high quality mechanical climate and UV resistant glass reinforcd polyamide, hot dipped galvanized bolts & contact teeth RPG/3M make. Suitable for energiging for Line to L.T. Distributuonm box, size 95 to 25/16 sq,nn, as oer specification. ,
Supply of L.T. Bare Neutral connectors P.G. clamp, made of Aluminium 70sq.mm. to 70 sq.mm double bolt( For line to line jumpering ) ( As per drawing attached )& as per UPCL specification.
Supply of L.T. Bare Neutral connectors P.G. clamp, made of Aluminium 70sq.mm. to 25/16 sq.mm double bolt( For line to line jumppering ) ( As per drawing attached )& as per UPCL specification.
Supply of M.S. Earth Rod, As per specifrication.
Supply of heat shink type and caps suitable for LT.ACB as per UPCL Specification.
Supply of Earth wire GI 7/1.6 mm. 16 SWG.
Supply of mid span insulated jointing sleevs suitable for L.T. AB Cable.
Supply of Aluminium Lug 25mm.
Supply of Aluminium Lug 95mm.
Errection work. ( Annexure -II)
Dismantling of old ACSR Conductor( Dog/Weasel)( L.T. Line) including Re- rolling back its conductor, wire, clamp, insulator etc .including stacking and transportation of material to the UPCL stores : 3 phase 4 wire.
Dismantling of old ACSR Conductor( Dog/Weasel)( L.T. Line) including Re- rolling back its conductor, wire, clamp, insulator etc .including stacking and transportation of material to the UPCL stores : 2 phase 3 wire.
Dismantling of old ACSR Conductor( Dog/Weasel)( L.T. Line) including Re- rolling back its conductor, wire, clamp, insulator etc .including stacking and transportation of material to the UPCL stores : 1phase 2 wire.
Carrying the material from dump store to site of work(Approx dis. 01-10KM)P.C.C. Pole.
Carrying the material from dump store to site of work(Approx dis. 01-10KM)Cable & other material.
Erection & grouting of P.C.C. Pole8.5 Mtr. Long ( 180 kg. W/L )for reducing span of LT, ABC line including digging of pits 0.6x0.9x2.15 Mtr.grouting stone pad and making kiciking block in E&B And with fitting of all accessories & back filling with soil & boulder earthing complete work as per RESPO specification & as per direction of Engineer in charge : Single Pole
Erection of stay set 16x1800mm. pit size 0.6x0.9x1.2 Mtr. as per specifications including 7/16SWG stay wire, binding, nozzling of stay with bcking filling of pit with CC 1:4:8 in bottom to pit in size 0.60.complete work stay set will be provided by UPCL.
Laying , Stringing and sagging of AB cable size (3x95+ 1x70)
Laying of L.T. P.V.C. Cable (1x25sq.mm) for D.Box.
Laying of L.T. P.V.C. Cable (2x6sq.mm) for Consumer connection.
Laying of Stay wire as per specification.
Fixing of Dead End Clamps with I Hook. ( As per drawing attached ) & as per UPCL specification.
Errection of SMC 3 Phase L.T. Distribution Box, .Al.Bus bar RYB 25x6mm.Al. Busbar N. 40x6mm. ISO reputed company with Clamps with Nut & bolts. ( As per drawing attached )& as per UPCL specification.
Fixing of Suspension Clamp with I hook.with Nut & bolts. ( As per drawing attached ) & as per UPCL specification.
Fixing of M.S. Clamps made of M.S. Flat for P.C.C. Pole 8.5 Mtr. Of size 35x5sq.mm. duly red oxide painted with suitable size with fitted Nut and bols ans washer for M.S. Half C,aip for L.T. Distributyuon As per specirication of UPCL.
Fixing of Nut,bolt and washer for Dead End Clamps as per specification of UPCL.
Fixing of M.S. Clamps made of M.S. Flat for P.C.C. Pole 8.5 Mtr. Of size 50x6sq.mm. duly red oxide painted with suitable size with fitted Nut and bols ans washer for Suspension as per As per specirication of UPCL.
Fixing of Stay Clamps made of M.S. Flat for P.C.C. Pole 8.5 Mtr. Of size 50x6sq.mm. duly red oxide painted with suitable size with fitted Nut and bols ans washer for Suspension as per As per specirication of UPCL.
Fixing of insulation peering connectors body molded from high quality mechanical climate and UV resistant glass reinforcd polyamide, hot dipped galvanized bolts & contact teeth RPG/3M make. Suitable for jumpering for Line to Line Jumpering/tapping size 95 to 95sq,mm.
Fixing of insulation peering connectors body molded from high quality mechanical climate and UV resistant glass reinforcd polyamide, hot dipped galvanized bolts & contact teeth RPG/3M make. Suitable for energiging for Line to L.T. Distributuonm box, size 95 to 25/16 sq,nn, as oer specification. ,
Fixing of L.T. Bare Neutral connectors P.G. clamp, made of Aluminium 70sq.mm. to 70 sq.mm double bolt( For line to line jumpering ) ( As per drawing attached )& as per UPCL specification.
Fixing of L.T. Bare Neutral connectors P.G. clamp, made of Aluminium 70sq.mm. to 25/16 sq.mm double bolt( For line to line jumppering ) ( As per drawing attached )& as per UPCL specification.
Errection of M.S. Earth Rod, As per specifrication.
Fixing of heal shink type and caps suitable for LT.ACB as per UPCL Specification.
Fixing of Earth wire GI 7/1.6 mm. 16 SWG.
Erreection of mid span insulated jointing sleevs suitable for L.T. AB Cable.
Fixing of Aluminium Lug 25mm.
Fixing of Aluminium Lug 95mm.
Removal of Previous connections & Re-connection of Single Phase / Three Phase L.T. consumer service connection and shifting the mterers outside of the premises.
RAVI CONSTRUCTION CO
Sagar Engineering Company
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.63 MB
FormAandB.pdf
Other Document • 0.67 MB
tenderno02202021tenderdoduments.pdf
Tender Documents • 1.84 MB
technicalspecificationanddrawingtno02202021.pdf
Additional Documents • 3.47 MB
technicalspecifcationtno022021.pdf
Additional Documents • 1.24 MB
drawing39.pdf
Other Document • 3.47 MB
BOQ_28277.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .