Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC Award |
| 2 | L2₹1.5 Cr+₹3.3 L (2.21%)Rejected-AOC 443 V P O LIWAN 132001 | KARNAL | HARYANA | 132001 | ₹1.5 Cr+₹3.3 L (2.21%) | L2 | Rejected-AOC Reject |
| 3 | L3₹1.5 Cr+₹4.2 L (2.81%)Rejected-AOC SCT 3 H NO 2030 ROHTAK SCT 3 H NO 2030 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹1.5 Cr+₹4.2 L (2.81%) | L3 | Rejected-AOC Reject |
| 4 | L4₹1.5 Cr+₹4.4 L (2.94%)Rejected-AOC 7 WARD NO 7 PURANI ANAJ MANDI GOHANA 131301 | GOHANA | SONIPAT | HARYANA | 131301 | ₹1.5 Cr+₹4.4 L (2.94%) | L4 | Rejected-AOC Reject |
| 5 | L5₹1.6 Cr+₹7.2 L (4.84%)Rejected-AOC 464 21 NEW ANAJ MANDI TOHANA 125120 | FATEHABAD | HARYANA | 125120 | ₹1.6 Cr+₹7.2 L (4.84%) | L5 | Rejected-AOC Reject |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
15 Mar 2021, 10:00 amClosed
Executive Engineer, PHED No. 1 Gohana
Executive Engineer, PHED No. 1 Gohana Near MC Park Jind Road Gohana
PROVIDING CANAL BASED WATER WORKS AT TAJPUR TIHAR KHURD FOR GROUP OF 2 VILLAGES, HOUSEHOLD TAP CONNECTIONS AND LAYING THE BALANCE PIPE LINES IN VILLAGE HASANYARPUR TIHAR KALAN AND TAJPUR TIHAR KHURD DISTRICT SONIPAT
2021_HRY_161384_1
EIC Memo No. 15338-PHE/Mont dt. 23-02-2021
Open Tender
Civil Works
Works
450 days
Village Tajpur Tihar Khurd
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹3.0 L
Yes
9 Apr 2021
1 Mar 2021
15 Mar 2021
1 Mar 2021
15 Mar 2021
1 Mar 2021
Amount
RAW WATER PUMPING MACHINERY Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame-RAW WATER PUMPING STATION- 900 LPM X 25 M. Head
WATER WORKS TAJPUR TIHAR KHURD- 700 LPM X 12.50 M. Head
CLEAR WATER PUMPING MACHINERY-Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame- WATER WORKS TAJPUR TIHAR KHURD- 700 LPM X 45 M. Head
PANEL BOARDS FOR MOTORS Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items -(3.1)-For 2 no Pumping Sets of 900 LPM x 25 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 900 LPM x 25 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.1
(3.2)-For 2 no Pumping Sets of 700 LPM x12.50 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 700 LPM x 12.5 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.2
(3.3)-For 2 no Pumping Sets of 700 LPM x 45 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 700 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 2.1
Supply, erection, testing & commissioning of IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respevts with accessories like thimble etc.- 10mm2 3 Core
25mm2 3core
Sluice Valves / NRV & specials for Pumping Machinery- Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 including cost of jointing material complete in all respect. (IVC / VAG make, Kirloskar)- 100mm i/d
Supplying,fixing, testing & commissioning of DI swing check type reflux valve (non returned valve) PN 1.6 including cost of jointing material complete in all respect.( IVC / VAG , Kirloskar make) - 100mm i/d
Supply, fixing & testing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect.- 100mm i/d
Supply, erection, fixing & testing of DI Double flanged pipe complete with all jointing materials- 100mm i/d
Sluice Valves/ Specials For Rising Mains - Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 as per DNIT specification on the pumping machinery & head works including cost of jointing material (IVC / VAG make)- 150 mm i/d
Supply & Fixing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect.- 150 mm i/d
Providing & fixing of D.I. Kinetic Air Valve soft seated as confirming to I.S.I. complete in all respect.- 80mm
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete in all respect.
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect.
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification.
Providing & fixing suitable size floating along with swivel bend as per required specifications approved by Engineer-in-Charge
Supply erection testing of reputed make LED light 100 wats with fittings and accessories complete in all repects.
Supply erection testing and commissioning of Flow Meter (KRONE Make) with digital display of 150 mm i/d complete in all respect.
Providing & fixing in position GI elbow ISI marked complete in all respect 15 mm i/d 304 x 4 = 1,216
Providing & fixing in position GI Nipple ISI marked complete in all respect 15mm x150mm /100 mm 304 x 2 = 608
Operation & Maintenance - Operation & maintenance for the complete scope of work mentioned in the DNIT (Disinfection material will be supplied by the PHED) as per schedule-IV during Defect liability period of 12 months after trial run period of 3 months & 5 years thereafter. (Will be charged to A/mtc estimate)." - (i) Defect liability period (Operation Only)
(ii) Operation & maintenance during 1st year
(iii) Operation and maintenance during 2nd year
(iv) Operation and maintenance during 3rd year
(v) Operation and maintenance during 4th year
(vi) Operation and maintenance during 5th year
Bidder Name
Amount
Surinder Singh Hooda(GSTN-06AABPH9599L2Z1)
Krishan Kumar(GSTN-06ATZPK0120H1ZQ)
Sunil Kumar(GSTN-06BMGPK6616K1ZU)
RAVI PARKASH CONTRACTOR(GSTN-06AJMPP2964K1ZN)
Sh. Rajpal Dahiya(GSTN-06AAOPD6073EIZT)
Jai Shree Balaji Constn Co.(GSTN-06AKLPK7500N1ZV)
ROHTASH KUMAR CONTRACTOR(GSTN-NA)
Sunil Kumar Bansal(GSTN-NA)
NAFE SINGH CONTRACTOR(GSTN-NA)
Surinder Singh Hooda
Jai Shree Balaji Constn Co.
Sh. Rajpal Dahiya
Sunil Kumar Bansal
Sunil Kumar
ROHTASH KUMAR CONTRACTOR
RAVI PARKASH CONTRACTOR
NAFE SINGH CONTRACTOR
Sunil Kumar
Sunil Kumar Bansal
Surinder Singh Hooda
Krishan Kumar
RAVI PARKASH CONTRACTOR
NAFE SINGH CONTRACTOR
Jai Shree Balaji Constn Co.
ROHTASH KUMAR CONTRACTOR
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .