Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.9 LAccepted-AOC | ₹3.9 L | L-1 | Accepted-AOC Lowest-1 |
| 2 | L-2₹4.1 L+₹24,020 (6.16%)Rejected-Finance | ₹4.1 L+₹24,020 (6.16%) | L-2 | Rejected-Finance Lowest-2 |
| 3 | L-3₹4.2 L+₹26,620 (6.83%)Rejected-Finance | ₹4.2 L+₹26,620 (6.83%) | L-3 | Rejected-Finance Lowest-3 |
| 4 | L-4₹4.2 L+₹28,020 (7.18%)Rejected-Finance | ₹4.2 L+₹28,020 (7.18%) | L-4 | Rejected-Finance Lowest-4 |
| 5 | L-5₹4.2 L+₹31,020 (7.95%)Rejected-Finance NOT AVAILABLE | ₹4.2 L+₹31,020 (7.95%) | L-5 | Rejected-Finance Lowest-5 |
| Sl No | Description | Qty | Unit | RAMESH KUMAR L5 | DHANANJAY SINGH SLATHIA L3 | Lekh Ram L4 | General Machinery Corporation L1 | KIRAN L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing, supplying, inatallation and commissioning of horizontal spindle horizontal/ vertical split casing single/ Multistage centrifugal/ Reciprocating pumps of standard make such as KSB/ Mather & Platt/ Jyoti/ Kirloskar/ Best & Crompton/ BE conforming to BIS : 5120-1980 (latest with up to date ammendments), read with BIS : 9137-1978 or latest to handle clear water having turbidity up to 50 PPM, with impellers, casing ring and shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/ Siemen/ Crompton/ NGEF/ Jyoti/ ABB/ Marathon Squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below:- | 1 | Set | 4,21,000 ₹4,21,000 | 4,16,600 ₹4,16,600 | 4,18,000 ₹4,18,000 | 3,89,980 ₹3,89,980 Lowest | 4,14,000 ₹4,14,000 |
| 1.01A) SITE CONDITIONS:- Location of site- About 8 Kms. from Nerchowk to Baggi. The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mtrs-. Altitude of place is 800 m above MSL. Humidity-Weather generally remains humid during monsoon season. Nature of atmosphere- As normally encountered in Shivalik Ranges. Detail of quality of water- Clear cold water. Water free from sand or not-Yes. Water corrosive or not- No.Turbidity- Clear cold water. NPSH available - N.A. Any other information or requirement - B).OPERATING CONDITIONS:- Type of current-A.C Three/Single phase. Operating frequency-50 HZ. Rated voltage-415(+ / -) 10% volts. System of earthing if any to be adopted-Double loop earthing as per the BIS-3043-1987 latest with upto date ammendments., Speed of revlution: To be quoted by tenderer, Direction of rotation:- to be quoted by tenderer, No. of working hours per day- 8 Hours. Speed of revolution in RPM-To be quoted by tenderer. Direction of rotation-To be quoted by tenderer. The max. temp. of cooling air & water in the place in which the pumpset is intended to work in ordinary service.- 35 Degree centigrate. | ||||||||
| 1.02C) MOTOR:- Ref. to BIS code-BIS 325-1978 read with BIS 900-1992 (latest) with upto date ammendments. Type of enclosure of motor with BIS 4691-1985 -SPDP (as per the BIS 4691-1985, Latest). Type of duty-Continuous. Mechanical out put in KW-Suitable for driving submersible pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. Class of insulation-Class-B/F .Max. permissible temp. rise of motor reqd. if different from that given in B (viii) above.-To be specified by the tenderer. Particulars of test required & where they are to be conducted.-as per the terms & conditions attached.Particulars as to whether voltage limiting device will be employed-ATS/Star Delta starter oil immersed, fully automatic to be installed between bus bar chamber & motor. Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE:- Start delta starter upto 37.5KW & ATS for 37.5 KW & above & stator rotor starter with slip ring motor beyond 50 KW.Motor whether squirrel cage or slipring -Squirrel cage:-Note:- Squirrel cage upto 65HP & slipring above. Details of shaft extension required.-Just sufficient to provide direct drive by flexible coupling to pump.Type of slipring gear whether continously rated or for starting purposes only and whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required-Continously rated for squirrel cage motor.Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.-Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.Nature of load & any information regarding the driven machine which has a bearing upon the torque required during the accelerated period. The kinetic energy of the moving parts to be accelrated & No. of starts during a specified period.-To work the pump offered.Where possible fault capacity of the system to which the motor is connected.-The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages of permanent deformations. | ||||||||
| 1.03D) PUMPS: BIS 1520-1980,read with BIS 9137-1978 both latest with upto date ammendments. Nos of pumps reqd.- 2 Nos. pumps ( one will act as stand by).Spare parts required-For Two years normal maintenance as recommended by manufacturer. type of drive:- Electric induction motor , Optional fittings reqd.-Air cock for exhausting air from each stage.E) Pump operating conditions.Capacity-12.60 M3/H. Total head in Mts.-323 Mtrs.(If total head in not known then following details be provided): Static Head- 24.20 Mtrs.Minimum depth of water-………….Mtrs.Variation in water level.-………….Mtrs.Ground level to max. water level- Mtrs.Ground level to delivery point- .Mtrs.Pressure in the suction tank-…………..Kg/cm/2.Pressure in the delivery tank-…………..Kg/cm/2.Length of R/main-1380 mtrs..Dia of R/main-80 mm Dia (MC).Drive arrangement-Direct through flexible coupling on a common base plate.Drive type-Electric driven.NPSH required:-To be quoted by tenderer.Limits of total head in which the pump is reqd. to operate.- (-) 15% to (+) 10% of total head.Suction/delivery size of pump-To be specified by the tenderer.Efficiency of pump at-To be specified by the tenderer. a.duty head . b.(+) 10% head c.(-)15% head . Material of construction-To be specified by the tenderer (Manufacturers certificate to be appended). | ||||||||
| 2.00Credit of existing Pumping Machinery @ 3.45 % (-) | ||||||||
Tender Value
₹4.2 L
EMD Value
₹8,500
Closing Date
2 Jan 2026, 5:00 pmClosed
Executive Engineer
JSD Baggi
Providing, supplying and installation of 30 HP Pumping Machinery
2025_HPIPH_124296_1
23846-896 dated 23-12-2025
Open Tender
Civil Works
Item Rate
90 days
Baggi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
₹8,500
27 Aug 2026
23 Dec 2025
3 Jan 2026
24 Dec 2025
2 Jan 2026
24 Dec 2025
24 Dec 2025 - 2 Jan 2026
Providing, supplying, inatallation and commissioning of horizontal spindle horizontal/ vertical split casing single/ Multistage centrifugal/ Reciprocating pumps of standard make such as KSB/ Mather & Platt/ Jyoti/ Kirloskar/ Best & Crompton/ BE conforming to BIS : 5120-1980 (latest with up to date ammendments), read with BIS : 9137-1978 or latest to handle clear water having turbidity up to 50 PPM, with impellers, casing ring and shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/ Siemen/ Crompton/ NGEF/ Jyoti/ ABB/ Marathon Squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below:-
A) SITE CONDITIONS:- Location of site- About 8 Kms. from Nerchowk to Baggi. The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mtrs-. Altitude of place is 800 m above MSL. Humidity-Weather generally remains humid during monsoon season. Nature of atmosphere- As normally encountered in Shivalik Ranges. Detail of quality of water- Clear cold water. Water free from sand or not-Yes. Water corrosive or not- No.Turbidity- Clear cold water. NPSH available - N.A. Any other information or requirement - B).OPERATING CONDITIONS:- Type of current-A.C Three/Single phase. Operating frequency-50 HZ. Rated voltage-415(+ / -) 10% volts. System of earthing if any to be adopted-Double loop earthing as per the BIS-3043-1987 latest with upto date ammendments., Speed of revlution: To be quoted by tenderer, Direction of rotation:- to be quoted by tenderer, No. of working hours per day- 8 Hours. Speed of revolution in RPM-To be quoted by tenderer. Direction of rotation-To be quoted by tenderer. The max. temp. of cooling air & water in the place in which the pumpset is intended to work in ordinary service.- 35 Degree centigrate.
C) MOTOR:- Ref. to BIS code-BIS 325-1978 read with BIS 900-1992 (latest) with upto date ammendments. Type of enclosure of motor with BIS 4691-1985 -SPDP (as per the BIS 4691-1985, Latest). Type of duty-Continuous. Mechanical out put in KW-Suitable for driving submersible pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. Class of insulation-Class-B/F .Max. permissible temp. rise of motor reqd. if different from that given in B (viii) above.-To be specified by the tenderer. Particulars of test required & where they are to be conducted.-as per the terms & conditions attached.Particulars as to whether voltage limiting device will be employed-ATS/Star Delta starter oil immersed, fully automatic to be installed between bus bar chamber & motor. Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE:- Start delta starter upto 37.5KW & ATS for 37.5 KW & above & stator rotor starter with slip ring motor beyond 50 KW.Motor whether squirrel cage or slipring -Squirrel cage:-Note:- Squirrel cage upto 65HP & slipring above. Details of shaft extension required.-Just sufficient to provide direct drive by flexible coupling to pump.Type of slipring gear whether continously rated or for starting purposes only and whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required-Continously rated for squirrel cage motor.Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.-Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.Nature of load & any information regarding the driven machine which has a bearing upon the torque required during the accelerated period. The kinetic energy of the moving parts to be accelrated & No. of starts during a specified period.-To work the pump offered.Where possible fault capacity of the system to which the motor is connected.-The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages of permanent deformations.
D) PUMPS: BIS 1520-1980,read with BIS 9137-1978 both latest with upto date ammendments. Nos of pumps reqd.- 2 Nos. pumps ( one will act as stand by).Spare parts required-For Two years normal maintenance as recommended by manufacturer. type of drive:- Electric induction motor , Optional fittings reqd.-Air cock for exhausting air from each stage.E) Pump operating conditions.Capacity-12.60 M3/H. Total head in Mts.-323 Mtrs.(If total head in not known then following details be provided): Static Head- 24.20 Mtrs.Minimum depth of water-………….Mtrs.Variation in water level.-………….Mtrs.Ground level to max. water level- Mtrs.Ground level to delivery point- .Mtrs.Pressure in the suction tank-…………..Kg/cm/2.Pressure in the delivery tank-…………..Kg/cm/2.Length of R/main-1380 mtrs..Dia of R/main-80 mm Dia (MC).Drive arrangement-Direct through flexible coupling on a common base plate.Drive type-Electric driven.NPSH required:-To be quoted by tenderer.Limits of total head in which the pump is reqd. to operate.- (-) 15% to (+) 10% of total head.Suction/delivery size of pump-To be specified by the tenderer.Efficiency of pump at-To be specified by the tenderer. a.duty head . b.(+) 10% head c.(-)15% head . Material of construction-To be specified by the tenderer (Manufacturers certificate to be appended).
Credit of existing Pumping Machinery @ 3.45 % (-)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
FORM6.pdf
Tender Documents • 0.42 MB
TC.pdf
Tender Documents • 0.06 MB
BOQ_182636.xls
BOQ • 2.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .