Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹36.5 L+₹6.1 L (19.9%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | L3₹36.7 L+₹6.3 L (20.6%)Rejected-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-AOC Rejected being higher bidder | |
| 4 | L4₹39.0 L+₹8.5 L (28.0%)Rejected-AOC 21 KISHORE BHAWAN MALVIYA NAGAR AIR FORCE JODHPUR RAJ 342011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L4 | Rejected-AOC Rejected being higher bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 May 2025, 6:00 pmClosed
GE AF JODHPUR
GE AF JODHPUR RATANADA JODHPUR 342011
REPAIR/ REPLACEMENT OF SECURITY LIGHT/ STREET LIGHT, HIGH MAST, FLOOD LIGHT AND SEARCH LIGHT IN DOMESTIC AREA AND KAYLANA AT AF STATION JODHPUR
2025_MES_706568_1
8410/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JODHPUR
₹80,000
Yes
15 Jul 2025
3 May 2025
31 May 2025
3 May 2025
29 May 2025
17 May 2025
Amount
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for laying cables and getting out in hard/dense soil complete all as specified and directed.
Returning filling in excavated soil including spreading levelling and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed.
Taking down/out from trenches/wall/pole old unserviceable LT cable of size 2 Core x 10 Sqmm complete all as specified and directed.
Taking down/out from trenches/wall/pole old unserviceable LT cable of size 3.5/4 Core x 16 to 35 Sqmm complete all as specified and directed.
Supply, laying, connecting and testing of XLPE armoured LT UG cable 1100 volts grade of size 2 core x 10 Sqmm heavy duty aluminium stranded conductor with PVC insulated, including suitable sizes of aluminium lugs and gland packing complete all as directed and specified. Note:- Earth work, DWC pipe, GI pipe will be measured and paid separately.
Supply, laying, connecting and testing of XLPE armoured LT UG cable 1100 volts grade of size 4 core x 16 Sqmm heavy duty aluminium stranded conductor with PVC insulated, including suitable sizes of aluminium lugs and gland packing complete all as directed and specified. Note:- Earth work, DWC pipe, GI pipe will be measured and paid separately.
Taking down/ out LT UG cable of size 2 x 10 Sqmm to 3.5 x 25 Sqmm from trenches/ ducts/ wall for repair of cables and re-laying/ re-fixing in the same location including re-connecting and testing on load complete all as specified and directed. Note : Earth work, DWC pipe, protection pipe, joint kit, cable cover shall be measured and paid separately under respective items.
Taking down/ out LT UG cable of size 3.5 x 35 to 95 Sqmm from trenches/ ducts/ wall for repair of cables and re-laying/ re-fixing in the same location including re-connecting and testing on load complete all as specified and directed. Note:- Earth work, DWC pipe, protection pipe, joint kit, cable cover shall be measured and paid separately under respective items.
Supply and laying in repairs (HDPE) DWC pipe size 50 mm dia for LT cable protection including sockets, bends etc complete all as specified and directed by Engr-in-Charge.
Supply and laying in repairs (HDPE) DWC pipe size 90 mm dia for LT cable protection including sockets, bends etc complete all as specified and directed by Engr-in-Charge.
M&L in repairs for earthing complete with GI earth plate electrode 60 cm x 60cm x 6.0 mm thick and buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to GI earth plate with GI wire of size 04 mm dia by means of bolts, nuts and washers of steel all as shown in electrical plate No.3 including PCC pit (1:3:6) type C-1 in cement concrete, 40 mm thick precast RCC cover in (1:2:4) type B-1 reinforced with 8 mm dia MS round bar @ 75 c/c both ways with 01 No lifting handle of 12 mm dia MS plain bar, GI pipe 15 mm dia light grade for GI wire protection and GI tubing 20 mm, medium grade for watering including GI funnel with wire mesh etc complete all as specified and directed by Engineer-in-Charge. Note:- GI earth wire and earth protection pipe upto 7.5m lenth shall be included in the quoted rate.
Supply, fixing & connecting in repair of FRLS PVC insulated twin core 2.5 Sqmm unsheathed multistranded copper conductor complete all as specified.
Supply and fix in repairs on pole/wall PVC conduit super quality size 20 mm dia complete all as specified & directed by Engineer-in-Charge.
Supply and fix in repairs of 6 sqmm 2 core, LT 1100 volts grade, PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt in service connections etc complete all as specified & directed.
Material and labour in repairs for 40mm bore GI tubing light grade laid in trenches/fixed to poles, walls etc as protection of service cable all as specified of the following sizes.
Material and labour in repairs for 50mm bore GI tubing light grade laid in trenches/fixed to poles, walls etc as protection of service cable all as specified of the following sizes.
Supply & fixing in replacement of LED street light 70W made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed.
Supply and fixing in replacement of LED street light 90W made up of pressure die-cast housing with epoxy powder coated dark graphite grey colour finish with IP 66 protection 230 Volt with all connected acessories all as specified and directed.
Supply and fixing in replacement of LED street light 120W made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed.
Supply & fixing in replacement of LED flood light 150W made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed.
Supply & fixing in replacement of LED flood light 200W made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed.
Supply and fixing in replacement of energy efficient integrated LED Solar street light fittings 40 Watts with inbuilt lithium battery of capacity 36 AH toughned glass having IP 66 protection, 230 volts lighting source with all connected accessories all as specified and directed.
Supply and fix in repair GI pipe bracket bent to shape drilled welded made out of light grade 40 mm dia bore GI pipe 0.9 mtr long for fixing of street light fitting of any type and description including suitable size of MS clamps, nuts, bolts and washers including two coat of aluminium paint over one coat of primer complete all as specified and directed.
Supply and fix in repair GI pipe bracket bent to shape drilled welded made out of light grade 32 mm dia bore GI pipe 0.9 mtr long for fixing of street light fitting of any type and description including suitable size of MS clamps, nuts, bolts and washers including two coat of aluminium paint over one coat of primer complete all as specified and directed.
S&F in repair PVC cable Junction box for street light including 6 Amp MCB SP 'C' series with aluminium bus bar TPN for controlling the street lights complete with pole mounting type size 300 x 200 x 105mm with 02 Nos. MS clamp of MS flat iron with bolts, nuts and washer complete all fixed on poles/walls as directed by Engineer-in-Charge.
Supply and fixing in repairs MCB DP 06 to 32 Amp, 'C' series complete all as specified and directed.
Supply and fix in repairs MCB 04 pole 40 Amp, 'C' series complete all as specified and directed.
M&L for painting of steel tubular LT poles of 9.0/11 mtrs with two coats of aluminium paint including painting to cross arms and clamps etc including preparation of surfaces by scrubing and cleaning with wire brush complete all as specified and directed.
M&L for marking of pole serial number with black luminous words on luminous yellow round sticker as per sample complete as per directed & specified.
Supply, fixing and testing in repairs of decorative LED post top lantern 40 watt with IP 65 protection complete all as specified and directed.
Attending and fault detection of day to day street / security light (LED, MH/ SODIAM Flood light fittings etc. of any make) complaints received through telephone or in person and rectification of defects installed on Dispersal & High Mast light poles,Sun Shelter lights, Hanger light, perimeter light, watch tower light bringing down the fittings on ground or in position including cleaning of glass/ acrylic cover for clear reflection of light, jumper fixing, loose connection, GI bracket tightening, checking the connection of street light FRP junction box, light allignment, replacement of flexible wire, tightening of flood light safety chain in Hangers, Proper insulation of cannection (VMTL Vehicle, ladder, tools, LT tape and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. Note : (i)Light fitting,MH CHOKE,MH bulb, ignitor,driver,SPD if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ for supply only. (ii) Contractor shall provide / deputed sufficient number of electricians and helpers ( as directed by Engineer-in-charge) to attend the complaints and reactified the same within 24 hours of receipt of complaints. (iii) Contractor manpower should attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Contractor will depposit new material to Engineer in charge for acceptance and then material will be issued by JE E/M on daily basis on assesment of complaints. (v) Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract.as directed by EIC.
Material & labour for attending of complaint of existing 12mtr long high mast light of any type, any wattage & any make, complaints received through telephone or in person and identification of defects, bringing down the system upto a normal heigt by manual/motorized mechanism & fixing at the same position after rectify the defect including flexible wire of required size, cleaning of light fittings for clear reflection of light, as required to make the light fitting functional (Vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement). Note : - (i) Contractor shall be provide / depute sufficient number of electricians and helpers ( as directed by Engineer-in-charge) to attend the complaints and rectified/replacement of parts shall be measured and paid separately under supply only items. (ii) Contractor manpower shall attend daily to receive complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes.
M&L for repair of mechanism of high mast and rewinding of three phase tower motor 440 Volt AC and including dismantling from high mast transport to workshop for rewinding with existing size of super enameled copper wire, replacing of gear, bearing bush etc for running of rope at satisfoctory level and reinstallation complete all as specified and directed.
Supply only electric driver 75 watt complete all as specified and directed.
Supply only electric driver 90 watt complete all as specified and directed.
Supply only electric driver 100 watt complete all as specified and directed.
Supply only electric driver 150 watt complete all as specified and directed.
Supply only surge protection device rated 5kv for LED type fitting complete all as specified and directed.
Supply & fixing in repair of automatic street light timer using nature switch for automatic switching of street light based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminal should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FF grade SMC junction box (sintex make) confirming to IP 54 suitable for three phase of 12KW model -Swadeep -02EC12kW3P of make -Nature switch or equivalent in legrand/siemens as approved by GE.
Supply and fixing in repair modular power contactor type MNX 9 of rating 9 Amp complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair modular power contactor type MNX 12 of rating 12 Amp complete all as specified and directed by Engineer-in-Charge.
KAVYA ENTERPRISES (BID ID -3299689)
SANJOLI CONSTRUCTION COMPANY (BID ID -3301711)
GANPATI ENTERPRISES (BID ID -3304853)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .