Loading…
Loading…
Tender Value
₹7.2 Cr
EMD Value
₹14.5 L
Closing Date
8 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
S&T works in c/w compliance of RDSO TAN for Automatic Fire detection and alarm system and earthing and bonding arrangement over Jodhpur Division.
SNT-JU-10-2026-27
SNT-JU-10-2026-27
Open
12 Months
Jodhpur, Rajasthan
₹0
₹14.5 L
15 Jun 2026
15 Jun 2026
24 Jun 2026
NS-A- NON-SOR ITEMS SUPPLY/SUPPLY AND INSTALLATION
NS-B (NON-SOR ITEMS- INSTALLATION/EXECUTION)
Item Breakup - A-SOR ITEMS
10.00 single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn.No.IRS:S- 76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply
of (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 140 conductor each dia 0.30 +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply
of (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 127 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board.Inspection Charges: (i)Borne by Railways(ii) NonePayment Terms: 100% on Supply JODHPUR DIVISION-S AND T/NORTH WESTERN RLY
of (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 277 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.554 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply
300.00 PBT and as per RDSO Drg. No. SA-23748 (Alt. 4) or latest and RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply.
300.00 deteriorating type low voltage cartridge fuse as per RDSO Specn.No.IRS:S-78/92 or latest and Capacity - 2/4/6/10A/16A/20A Amp. (material will be supplied only from approved vendors of RDSO). Inspection: Consignee Inspection Charges: Borne by Railways. Payment Terms: 100% on supply.
40.00 Device (SPD) -Type I & II with Visual Indication and Potential free contact to remote monitoring as per Specification No. RDSO/SPN/165/2023 Ver 4.0 or latest and IEC standard 61643 or latest and IEC 62304-5 or latest for Single phase 230V AC application with handling Lightning surges of 10/350 microseconds and Switching surges of 8/20 microseconds .One Set consists of 3 nos. of SPD (2 No. of B Class (L-N, N-E) and one no. of C Class (L-N) all enclosed in a Box with KEMA or VDE certified as per latest IEC 61643-11-2011 Standard or latest. Class B & C Surge protection device required with Three modules only. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after supply.
20.00 protection Device (SPD) -Type I & II. All fitting material to be provided by the contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after execution. JODHPUR DIVISION-S AND T/NORTH WESTERN RLY
200.00 24-60V AC/DC supply as per clause No.3.11.2 of Specification No. RDSO/SPN/165/2023 Ver 4.0 or latest. The Class C shall be with pluggable type, with indication and potential free contact. The supplier should submit OEM certificate, KEMA, UL Certificate with the material, for connection between L1-L2, L1-E & L2-E. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after supply.
installation commissioning of Heat and smoke multi sensor as per RDSO/SPN/217/2025 ver- 3.1 or latest. along with its base, back- box and all accessories incompliance with IS:2175 and IS:11360 standard sand Under writers Laboratory (UL) listed. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution.
installation, testing commissioning Fault isolator as per RDSO/SPN/217/2025 ver-3.1 or latest with backbox and all other accessories Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution.
5000.00 sq.mm unarmoured as per RDSO/SPN/217/2025 ver-3.1 or latest Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply.
installation, commissioning of Networkable single loop addressable Fire alarm Control panel expandable up to 4 loops with GSM interface as per RDSO/SPN/217/2025 ver- 3.1 or latest. This work involves supply, fixing, installation and testing of control p a n e l . The control panel shall be networkable t o Z o n a l /Divisional headquarters preferably over TCP/lP and shall have clock synchronization facility. This includes Networking module (TCP/IP) for control panel along with power supply unit and battery set of required capacity for 24 hours backup as per RDSO specification. The panel should support degrade mode operation in compliance w i t h I S : 2189, EN54 s t a n d a r d s and Underwriters Laboratory (UL) listed. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution.
installation, commissioning of Manual call point (resettable) with backbox and all other accessories as per RDSO/SPN/217/2025ver-3.1 or latest Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution. JODHPUR DIVISION-S AND T/NORTH WESTERN RLY
installation, testing commissioning of Hooter and Visual strobe alarm units with backbox and all other accessories as per RDSO/SPN/217/2025 ver-.3.1 or latest along with its power supply unit. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution.
installation, testing commissioning of Control module with backbox and all other accessories a s per RDSO/SPN/217/2025 v e r- 3 . 1 or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution
installation, commissioning of EOL as per RDSO/SPN/217/2025 ver-3.1 or latest as directed by the site engineers Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution
installation, testing commissioning of Monitor module for 3rd party with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution
Fire installation, testing and commissioning of CO2 fire extinguisher 6.5kg capacity conforming t o IS15683 w i t h I S I mark provided with all fittings and accessories. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution
2000.00 sq.mm armoured as per RDSO/SPN/217/2025 ver-3.1 or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply.
20.00 of Medium size - the weight of the agent is not less than 1.0 kg but less than 1.8kg. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply.
400.00 Dia (3.6 mm thickness) as per IS 1239 (Part 1): 2004 for use in ASM room and at any other location as decided by Site Engineer. It includes supply of all material required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply JODHPUR DIVISION-S AND T/NORTH WESTERN RLY
400.00 Dia (3.6 mm thickness) as per IS 1239 (Part 1): 2004 for use in ASM room and at any other location as decided by Site Engineer. It includes installation of all material required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe along with any masonry work (if required) will be provided by contractor to protect cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Installation.
800.00 (DWC) HDPE Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 50 mm outer Dia, & 38 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers3) Tees4) Bend,5) End-cap(The total quantity of above items is equal to no. of pipes supplied.)DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs or as per extant policy (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs or as per extant policy Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% after Supply JODHPUR DIVISION-S AND T/NORTH WESTERN RLY
450.00 and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth levelling of trenches & restoring the original surface of trenches. The sharp edges will be smoothened out in bottom of the chase and will be levelled properly. In hard rocky ground area, cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground cannot be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables are small. In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.l.2 mtr is not possible and it will be decided by site engineer/unit officer incharge of work. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution
6000.00 pairs/ quads in trenches/ GI pipes/ RCC Metre pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution
20.00 items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor)(cum is Cubic Meter). Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution
5000.00 25x3mm for perimeter bonding in S&T rooms as per RDSO Drg. No. SDO/RDSO/E&B/001 or latest. Inspection: Consignee Inspection charges: Borne by Railways Payment terms: 70% after supply, 20% after installation & 10% after commissioning Total 16069421.30 JODHPUR DIVISION-S AND T/NORTH WESTERN RLY
Item Breakup - NS-A- NON-SOR ITEMS SUPPLY/SUPPLY AND INSTALLATION
Supply of basic material to construct unit Numbers maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm diawith copper bonding thickness of minimum macrons and UL listed and marked = 1 no. Inspection: RDSO.
Installation of Unit Maintenance Free Numbers Earth. It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode.(iii) Filling of earth enhancing compound (approx. 30 Kg) (iv) Provision of exothermic weld connections to copper Strip to the earth electrodes. (v) This also includes supply and fixing of CC cover 1.5 ft x 1.5 ft.1 ft wall thickness 2 inch with cover 3-inch thickness. All material tools and fixtures required for weld will be arranged by contractor. Inspection: Consignee.
Supply of Tinned Copper LUGs for fitting Numbers in Cable. Size: 10 sqmm, Barrel Inner-dia: 4.7mm, Barrel Outer-Dia: 7.1 mm, Barrel Length: 10mm, Stud Hole Center-dia: 9.9mm, Palm Width: 12.6 mm, Thickness: 1.8,Lug Length: 27 mm, Thimble Type: Ring. Inspection: Consignee
Supply of Copper Strip of cross section Metre size 25 mm X 6 mm . Inspection: Consignee
Supply of GI tape for ring earth of cross Metre section size 50 mm x 6 mm. Inspection :RITES
Installation of MEEB/SEEB/BRC with the Numbers insulators (As per the instruction of Site Engineer). Fitting materials & Insulator (Dough Moulding Compound Conical type of different Size) as per the site requirement to be supplied by the contractor. Note: 'No' in the unit column indicates 'per insulator'. Inspection: Consignee
Routing and connecting of all the Metre equipment in the equipment/relay room to SEEB with 10 sq. mm copper cable using copper lugs with stainless steel nut and bolts and fixtures. The work includes laying and routing the copper cable in PVC / conduits and fixing them on wall. The PVC/conduit pipe to be supplied by Railway. Inspection: Consignee JODHPUR DIVISION-S AND T/NORTH WESTERN RLY
Supply of PVC rigid plain medium class Metre conduit pipe of 50 mm dia with socket end having ISI mark as per specification No.IS:9537 (part-3)-1983 with latest amendment and IS: 9537 (part-1)-1980 with latest amendment . Inspection :Consignee
Supply,execution of exothermic weld for Numbers more than 16 sq mm wire. This includes welding kit, welding powder, mould and other necessary materials and tools for welding. Note: No. in unit column indicates per welding. Inspection: Consignee
Supply, execution of exothermic weld for Numbers upto 16 sq mm wire. This includes welding kit, welding powder, mould and other necessary materials and tools for welding. Note: No. in unit column indicates per welding. Inspection: Consignee
Supply of Nut Bolts, Washer (Stainless Set Steel) as per the site requirement (One set consists of 1 Nut, 1Bolt , 2 washer & 2 spring washer) Note :- Hex Nuts, bolts and washers of size 5/16. Inspection :Consignee
Supply of Earthing powder ( Earth Kg Enhancement Material ) as per Para 8.2 of RDSO Spn. No. RDSO/SPN/197 or latest Note :- Minimum weight of Bag should be of 10 KG. Inspection: Consignee
Masonry work for cutting hole through Job wall for insertion of cable and re instatement of wall with supply of required masonry materials and painting/white washing and repairing of wall with brick, sand,cement etc. after laying of cables as per instruction of site engineer. All masonry item to be supplied by the firm except cable. Inspection: Consignee
Cutting of floor surface/ concrete surface Metre for a depth of 20 cm & width of 10 cm & refilling/ reconditioning/repairing the surface after laying of pipe, cable. Cutting to be done with machine in proper manner & restore the same as before. Inspection: Consignee
Digging a trench to a minimum depth of Metre 0.5meter and laying 50 mm X 6 mm bare GI tape connecting all the earth pits and and Carrying out exothermic weld connections on all the earth electrodes along with materials , tools for welding. Earth enhancement compound of approx. 10 Kg per meter also to be spread along the GI tape and refilling, dressing of trench. Inspection: Consignee JODHPUR DIVISION-S AND T/NORTH WESTERN RLY
Digging a trench to a depth of at least Metre 0.5 meter and run the 35 sq. mm earth conductor in protective PVC conduit pipe, procured against supply item, from Earth pit to MEEB. Routing and exothermic termination of 35 sq. mm cable on earth conductors as well as on 300 mm X 25 mmX 6 mm MEEB, which is to be fixed inside the equipment room with two 60 mm insulation studs. The 60mm insulation studs have also to be supplied. Inspection: Consignee Total 19021609.20
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Correction slip 2
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
CTIndianRailwaysStandardGeneralConditionsofContractApril-
ATTACHMENT
SNT-JU-10-2026-27TenderDoc.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_8ACS-8.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_9ACS-9.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_10ACS-10.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_11ACS.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
AdvancecorrectionsliptoGCC2022.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_2.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-311.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT