| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹38.9 L+₹29,300 (0.76%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹41.8 L+₹3.2 L (8.37%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.9 L+₹8.4 L (21.7%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
24 Jan 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
PROVN OF 160 KVA TRANSFORMER AT DWARKA OKHA AND SPECIAL REPAIR TO TRANSFORMER AT INS SARDAR PATEL UNDER GE NAVY PORBANDAR
2021_MES_497749_1
9101/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹68,000
Yes
8 Feb 2022
28 Dec 2021
26 Jan 2022
28 Dec 2021
24 Jan 2022
11 Jan 2022
28 Dec 2021 - 10 Jan 2022
Amount
Dismantling/taking out all electrical connections from unserviceable 11 KV/433 Volts dry/oil type transformer of any capacity and lifting transformer with the help of crane & loading into vehcile and sending it to company workshop from site and after repairing send it to site back & re-connection of all electrical connections to transformer as per existing complete all as specified and directed by Engr-in-charge.
Drawing out 11 KV/433 Volts 100 KVA dry/oil type transformer core and winding, replacement of one phase burnt HV winding with suitable gauge of super enamelled copper winding including drying,brazing etc as per existing & also suitable type of insulation between coils and assembling the transformer after repair complete all as specified and directed by Engr-in-charge.
Drawing out 11 KV/433 Volts 100 KVA dry/oil type transformer core and winding, replacement of one phase burnt LV winding with suitable gauge of super enamelled copper winding including drying,brazing etc as per existing & also suitable type of insulation between coils and assembling the transformer after repair complete all as specified and directed by Engr-in-charge.
Drawing out 11 KV/433 Volts 200 KVA dry/oil type transformer core and winding, replacement of one phase burnt HV winding with suitable gauge of super enamelled copper winding including drying,brazing etc as per existing & also suitable type of insulation between coils and assembling the transformer after repair complete all as specified and directed by Engr-in-charge.
Drawing out 11 KV/433 Volts 200 KVA dry/oil type transformer core and winding, replacement of one phase burnt LV winding with suitable gauge of super enamelled copper winding including drying,brazing etc as per existing & also suitable type of insulation between coils and assembling the transformer after repair complete all as specified and directed by Engr-in-charge.
Drawing out 11 KV/433 Volts 630 KVA dry/oil type transformer core and winding, replacement of one phase burnt HV winding with suitable gauge of super enamelled copper winding including drying,brazing etc as per existing & also suitable type of insulation between coils and assembling the transformer after repair complete all as specified and directed by Engr-in-charge.
Drawing out 11 KV/433 Volts 630 KVA dry/oil type transformer core and winding, replacement of one phase burnt LV winding with suitable gauge of super enamelled copper winding including drying,brazing etc as per existing & also suitable type of insulation between coils and assembling the transformer after repair complete all as specified and directed by Engr-in-charge.
Low voltage testing of 11KV / 433V, 100 KVA to 630 KVA distribution dry / oil type Transformer i.e. open circuit test, short circuit test, magnetizing current, Magnetic balance & IR Value test after repairing of transforemer complete all as specified and directed by Engr-in-charge.
Painting of Transformer, 100/200/630 KVA capacity 11KV/433V, indoor dry type, with two coats of synthetic enamel paint (spray painting) after cleaning, scraping, and filling of cavities for external exposed surfaces of transformer & writing SM/MES No. capacity of transformer complete all as specified and as directed by Engineer-in-Charge.
HV bushing with insulator,studs nut & washers suitable for 11 KV/433 Volts HV side of transformer 100 KVA to 630 KVA fixed in repair / replacement complete as specified and directed by Engr-in-charge.
LV bushing with insulator, studs nut & washers suitable for 11 KV/433 Volts LV side of transformer 100 KVA to 630 KVA fixed in repair / replacement complete as specified and directed by Engr-in-charge.
M&L for DC power pack with battery back up complete enclosed in a metal enclosure made of 2mm thick mild steel CRCA sheet duly compartmentalise for batteries,charging system and control system with LED indicator lamps and toggle switch and push button ON/OFF system for charging, discharging etc as per requirement, front openable with locking arrangments with proper ventilation as per latest IS,suitable for supply of 01 No of 24 Volt DC 80 AH duly blanked with 2 Volt LED acid maintenance free batteries including float and trickle battery charging system suitable for input single phase 220 Volts 50 Hz ac supply including all electrical and control connection to existing socket for charging and DC supply to the existing VCBs.The connection of incoming and outgoing battery bank to VCBs will be made by stranded copper conductor size not less than 2.5 sq mm for each core in case of multi core cable fixed in repair / replacement complete all as specified and as directed by Engr-in-charge. Make :-Exide Powersafe, Model No-UPST-24V-80Ah or equivalent model of make specified.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI earth strip 32x6 mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 40mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion, as in replacement complete all as specified and directed.
Supply and lay in trenches / fixed to walls with saddles and fixing with screws etc GI earth strip of size 25 X 4 mm from earth pit to the test point provided all around the building for lightning protection and connecting up complete all as directed by Engineer–in–Charge Note : Excavation and earth work shall be measured and paid separately.
M&L for Copper bus bar any rating including cutting/drilling of suitable size holes as required at site including copper nut, bolt, washer fixed in repair / replacement complete all as specified and directed by Engr-in-charge.
M&L for Aluminium bus bar any rating including cutting/drilling of suitable size holes as required at site including GI nut, bolt, washer fixed in repair / replacement complete all as specified and directed by Engr-in-charge.
Maintenance & servicing of voltage satbilizer 100/200 KVA three phase 440 V for sub station / section indoor type after disconnecting incoming & outgoing LT connection / Earthing and opening the voltage stabilizer complete and cleaning throughly, removing, cleaning, providing new gasket and servicing of servo motors as recommended by manufacture insulating properly with genuine material and stabilizer body gasket re assembling the voltage stabilizer after repair / maintenance of voltmeter, ammeter, PF meter, indicator lamp RYB, servo motor, resistance contact and remounting on foundation complete with connecting back all removed electrical connection and testing on completion of functioning of voltage stabizer completed all as specified and directed by Engr-in-charge.
Supply and fixing lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 Volts, fixed in repairs complete all as specified and directed.
Supply and fixing switch air break gang operated out door type HT 11 KV triple poles 200 Amps air break fittings type with fixed contacts of phosphorus bronze and moving contacts of copper with mechanically operating from ground level vertical mounted completed with HT insulator on steel frame operating rod made out of 25mm GI pipe medium grade worked from ground level with handle and locking arrangement with 12 insulators with drop out fuses with test complete all as specified and directed.
Supply and fixing switch air break gang operated out door type HT 11 KV triple poles 400 Amps air break fittings type with fixed contacts of phosphorus bronze and moving contacts of copper with mechanically operating from ground level vertical mounted completed with HT insulator on steel frame operating rod made out of 25mm GI pipe medium grade worked from ground level with handle and locking arrangement with 09 insulators with drop out fuses with test complete all as specified and directed.
Supply ,install, testing and commissioning of distribution transformer step down, oil cooled, copper wound LT and HT coil, Outdoor 160 KVA, ECBC-compliant having maximum allowable transformer losses of 1.88% at 50% load and 2.44% at full load complete with standard fittings , H T 11 KV,3 phase, LT 433 volts, 3 phase, 4 wire, vector group DYn 11 with off load tap changer switch on HT side to vary secondary voltage within limit (+) 5% , (-) 7.5 % in steps of 2.5 % AN all as per IS -11171-1985 with bushing on HT side suitable for flexible copper end connection duly filled with transformer oil as required quantity complete with all standard accessories as per IS specification and including coneecting to existing HT/LT connections all as specified and as directed. (a) Lifting lugs for transformer and tank. (b) Earthing terminals rating and diagram plate. (c) Air release divice lifting lugs for transformer and tank.
Supply and installing, testing and commissioning factory made, floor mounted indoor type 100 KVAR 6 Step relay contactor APFC Panel cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system with MCCB incommer free standing panel, Copper bus bar (Main) and CU bus bar (Earth) 3 mm thick outer body and 2 mm thick inner body CRCA sheet dust and vermin proof 2.5 sqmm size internal wiring complete all as specified and directed including the following accessories:- (a) 320A 3P 36KA MCCB TM Release, Type: DU250C, 415V AC, 50Hz - 01 No (b) Extended Rotary Handle for DU250C/DU250 MCCB - 01 No (c) Spreader Terminals - 3 Pole (Set of 6) for DU250C/DU250 MCCB -01 No (d) Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V A 01 - No (e) Yellow Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V A - 01 No (f) Blue Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V Ac - 01 No (g) 6 Steps APFC Relay for Contactor Switching with 1 CT Input: 1A/5A, Size: 96X96, Voltage: 415V AC, Type: ETASMART R - 01 No (h) 6A 1P 10KA, C-Curve MCB - 03 Nos (i) 4 Sq.mm Feed Through Terminal (Std. Color),Type: KUT 4 -01 No (j) End Plate(Std. Color), Type: KPX for Terminal: KUT4, KST 4UWS, KUT6, KUT10 - 01 No (k) Side Clamps with fixing Screws, Type: SCKN (POLYAMIDE 6.6) - 02 Nos. (l) 250A 4P onload manual changeover Switch- Discharging / Open Execution
M&L for Prestressed concrete pole,11m long, minimum cross section 152mm x 152mm at top and minimum cross section 152 x 260 at bottom, class 9 erected in true vertical position, including taking down and removal of damaged / broken pole complete all as specified. (Note :- Excavation/earth work, PCC in foundation/coping etc shall be measured and paid separately under respective items of Sch "A")
M&L for Cement Concrete 1:4:8 type D-2 (40mm graded crushed stone aggregate) as in foundations of poles, stays, ncluding formwork (as required), complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete or as in sub base complete all as specified and directed.
M&L for Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green,Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts, fixed in repairs , complete all as specified and as dircted.
M&L for DO fuse for 11 KV, 200 Amps, Frequency 50 Hz rated breaking capacity as per IS 93853 insulator D type, fixed in repairs, complete all as specified and directed.
M&L for Stone masonry walling or squared walling in cm 1:4, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
M&L for Rendering 15mm thick in cm 1:4 on stone masonry surfaces, finished surfaces even and smooth w/o using extra cement complete all as specified and as directed.
M&L for Stay assembly with 16mm dia meter of stay rod complete with accessories as shown in electrical plate No 1 with loop type insulator, stay clamps and stay wire, including taking dow old stay assemply complete all as specified and as directed. (Note : excavation and concrete will be measured and paid for separately).
M&L for MS angle/channel framed structure for support base reqd for fixing oflighting arrester,GOD,DO fuse using 'U' channel of any size & shape as required & ordered including all type of fabrication work including cutting ways, drilling necessay for accomodating suitable size bolts& nuts all as directed including dismantling/ taking old rusted broken items complete all as specified and directed.
Supply, laying, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 95 sqmm 3core suitable for working on 11000 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Supply and fixing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 120 sqmm 3.5core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Supply and fixing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 95 sqmm 3.5core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
S&F Cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination, heat shrinkable type complete with jointing material and accessories suitable for 3core XLPE armoured aluminium conductor cable of size 95 sqmm fixing complete all as specified and as directed.
M&L for Excavation in trenches in soft / disintegrated soil n.exc 1.5 m wide and n.exc 1.5 m deep and getting out for taking out/laying of cable, GI pipe lines and foundation compete all as specified and as directed.
M&L for Returning, filling in trenches in soil / rock incl spreading, levelling watering and ramming in layer n.exc 25 cm complete all as specified and directed.
M&L for Removing excavated material soil/rocks n.exc. 50 m, depositing where directed at a level n. exc. 1.5 m above the starting point, complete all as specified and directed.
M&L for Fine dry sand cushion in trenches for cable protection with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. NOTE:- Only compacted thickness will be measured and paid. The compacted thickness must be more than 18 cm.
M&L for Precast concrete cable cover unreinforced, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
M&L for Galvanised tubing light grade 80 mm nominal bore for passing of cable, fixed to poles / walls / laying under floor/ roads complete with and including fittings, clamps nut bolts as required complete all as specified and as directed.
M&L for Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion,as in replacement, complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Harsh Infrastructure
ABR Trading Co
K K Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .