Executive Engineer
Office of Executive Engineer, Div IV, PWD Tonca
Supply, installation, testing and commissioning of Air Conditioner units, in Goa Public Service Commission, at EDC Panaji Goa.
2026_PWD_32422_1
31/1/2026-27/ASW-IV/EMN/PWD/32 LINE11
Open Tender
Electrical Works
Percentage
15 days
Tonca Caranzalem
Please refer to tender notice
4 documents required · 4 mandatory
₹4,000
₹3,642
16 Oct 2026
16 Oct 2026
28 Oct 2026
16 Oct 2026
26 Oct 2026
16 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and Installation of High wall 5 star Inverter Split Type air conditioner of 2.0 TR capacity having in built time delay features, Refrigerant is of R32/ R22, 100% Copper Condenser, Auto start facility, three speed cooling capacity, oscillating louvers with rotary compressor suitable for operation on single phase 230 volt, 50 Hz, A.C. supply of make Blue star or equivalent in Voltas / Mitsubhishi / Daikin / Toshiba & Panasonic approved model (Model to be approved by the Engineer in Charge before the execution of work) | 1 | Each | 70,265 | ₹70,265 |
| 2 | Supply and Installation of High wall 5 star Inverter Split Type air conditioner of 1.5 TR capacity having in built time delay features, Refrigerant is of R32/ R22, 100% Copper Condenser, Auto start facility, three speed cooling capacity, oscillating louvers with rotary compressor suitable for operation on single phase 230 volt, 50 Hz, A.C. supply of make Blue star or equivalent in Voltas / Mitsubhishi / Daikin / Toshiba & Panasonic approved model (Model to be approv.ed by the Engineer in Charge before the execution of work) | 1 | Each | 56,200 | ₹56,200 |
| 3 | Providing and fixing of MS stand for split type outdoor unit | 2 | Each | 575 | ₹1,150 |
| 4 | Providing and fixing of Copper pipe with insulation as required | 10 | Mtr. | 1,093 | ₹10,930 |
| 5 | Providing and fixing of PVC drain Pipe with Fittings as required | 10 | Mtr. | 138 | ₹1,380 |
| 6 | Supply installation testing and comissioning of 4 KVA Voltage stabilizer of (Everest / V -Guard make) | 1 | Each | 2,300 | ₹2,300 |
| 7 | Supply installation testing and comissioning of 5 KVA Voltage stabilizer of (Everest / V -Guard make) | 1 | Each | 2,530 | ₹2,530 |
| 8 | Supply and fixing of Casing capping of size 100 x 50 mm per Meter | 6 | Mtr. | 748 | ₹4,488 |
| 9 | Providing of Core Cutting as required at site. | 2 | Each | 1,725 | ₹3,450 |
| 10 | Servicing of Split AC's of all makes and tonnage including replacement of different types of capacitors, relays, thermostat, overload protector, selector switches, air blower, fan motor shaft and bushes, rewinding of motor servicing of contactor contacts and replacement of contactor kit etc. (servicing of AC's once in 3 months) | 10 | Each | 750 | ₹7,500 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 7.70 MB
Tendernotice_3.pdf
PDF • 0.40 MB
BOQ_32805.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .