Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.0 L+₹1,786.88 (0.06%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹32.8 L+₹2.8 L (9.49%)Rejected-Finance 894 NEAR 132 KV POWER HOUSE SINDHARI ROAD BALDEV NAGAR BARMER RAJ 344001 | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹35.8 L+₹5.8 L (19.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹36.2 L+₹6.2 L (20.7%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹36.5 L
EMD Value
₹72,920
Closing Date
10 Jan 2024, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
SPL REPAIR / REPLACEMENT OF EARTHING, WIRING, OLD LIGHT FITTINGS AND CONNECTED WORKS AT GANDHINAGAR, PROVISION OF HIGH MAST LIGHTS FOR MTR AND S SECTION AT GANDHINAGAR AND CERTAIN MINOR WORKS UNDER GE (AF) CHILODA
2023_MES_632914_1
8991/23-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Gandhinagar
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹72,920
Yes
15 Feb 2024
15 Dec 2023
12 Jan 2024
15 Dec 2023
10 Jan 2024
29 Dec 2023
15 Dec 2023 - 28 Dec 2023
Amount
Taking down carefully copper/ aluminum point wiring of any size and description (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets light fittings etc. complete all as specified and directed.
Material and labour for point wiring for one light point or one fan point or one bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core,FRLS PVC insulated & unsheathed cable, 1100 volts grade drawn through concealed PVC conduit and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly with incl factory made GI sheet sunken box ,modular cover plate chrome collar with base frame and making good disturbed surface of walls, floors, etc. complete all as specified and directed.
All as per Serial item No. 2 here-in-before but point wiring for 3 pin socket outlet , 5 amps on same board.
All as per Serial item No. 2 here-in-before but point wiring for 3 pin socket outlet 5 amps on independent board.
All as per Serial item No. 2 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 2.5 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 amps complete all as specified and directed.
M&L for point wiring for one light or one fan or one bell point controlled by one switch with using 1.5 Sqmm single core FRLS PVC insulated unsheathed multi stranded copper conductor cable 1100V grade drawn through with including PVC casing in capping /conduit (size of as required at site but not less than 20mm) with accessories like bends tees, junction boxes and terminal boxes for mounting fittings etc. fixed on recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC insulated but unsheathed multistrandard copper conductor cable 1100V grade as earth continuity wire connected to common earth dolly with incl factory made GI sheet sunken box , cover plate and making good disturbed surface of walls, floors, etc. complete all as specified and directed.
All as per Serial item No. 6 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on same board.
All as per Serial item No. 6 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on independent board.
All as per Serial item No.6 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 2.5 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 amps complete all as specified and directed.
Supply & Fixing 10A Modular switch 1 way, 1 module complete all as specified and directed.
Supply & Fixing 20A Modular switch with LED Indicator, 1 module complete all as specified and directed.
Supply & Fixing 10A Modular Socket 3 pin with shutter, 2 module complete all as specified and directed.
Supply & Fixing Modular Socket 10A/20A, 2 in 1 combined with shutter, 2 module complete all as specified and directed.
Supply & Fixing Modular fan regulator 100 W, 5 speed step type, 2 module complete all as specified and directed.
Supply and fixing for switch piano flush type, 5 amps, single pole, one way, 230 volts AC complete all as specified and directed.
S & F for socket outlet, five pin, 5 amps, flush type, 230 volts AC complete all as specified and directed.
S & F for switch socket outlet combination, five pin, 5 amps, flush type, 230 volts AC complete all as specified and directed.
S & F for switch socket outlet combination, multipurpose, 3 pin, 15 amps and 3 pin 5 amps controlled by one switch, flush type, 230 volts AC complete all as specified and directed.
S & F for ceiling rose surface bakelite, three terminals complete all as specified and directed.
S & F fan regulator step type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 60 Watt complete all as specified and directed.
M & L for in replacement of sub main wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4 Sq.mm of 1100 Volts voltage rating drawn through and including PVC casing caping of size not less than 25mm with standard accessories, along-with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sq.mm as earth continuity conductor complete all as specified and directed. Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per Serial item No. 21 here-in-before but sub main wiring with using two single core 6.0 sqmm FRLS PVC insulated stranded copper conductor cable
S & F for PVC insulated aluminium stranded conductor of size 10.0 sq.mm twin core flat or circular cable 1100 volt grade, heavy duty cable , served with inner sheathed cable complete all as specified and directed.
Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 12 way with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified and directed.
All as per Serial item No. 24 here-in-before but 8 way
All as per Serial item No. 24 here-in-before but 4 way
Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 4 way TPN with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified and directed.
S & F in replacement MCB Triple pole & neutral (TPN), 32 to 63 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed.
S & F in replacement MCB single pole & neutral (SP&N), 16 to 32 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed.
S & F in replacement MCB single pole (SP) 6 to 32 Amps, 240 volts, 10KA, ‘B’ series, with proper size lugs and connections complete all as specified and directed.
S & F in replacement Surface and wall mounted high efficiency 1x20 watt LED batten, aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver CRI >80, Beam Angle 120° Lumen efficiency >110 Lm/W complete with all accessories internally pre wired and including connection up with twin core flexible copper conductior cable complete all as specified and directed.
S & F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10/12 watt 220 V AC Self Ballasted LED Batten. Lumen efficiency >110 Lm/W, Extruded Thermoplastic body with PC Diffuser in square shape, CRI >80, Beam Angle 120° including connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S & F in replacement LED light fitting 9W/10W bulkhead luminaires including LED light holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in replacement for outdoor type IP66, Energy saving LED street light fitting 30 Watt 230 V AC with PDC Aluminium body & Secondary optical lens for superior light distribution. Efficiency >110 Lm/W. with high pressure die cast aluminum hosing and heat resistant LED street light fitting with driver, complete all as specified and directed.
S & F in replacement for Decorative, wall mounting, brushed nickel finish fixture with dual Opal Glass diffuser suitable for LED lamp B22 Base complete all as specified and directed.
Fixing only old serviceable light fitting of any type complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as per shown in electrical plate No. 5 of MES Schedule Part-I with connected to earth test point main switch board with including necessary earth work and Pre- cast RCC earth pit with cover and including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed.
M & L for chemical earthing complete copper earth plate of copper earth plate of 900 x 600 x 5 mm buried directly in ground) Earth pit not less than 4.0 meter below the ground level with top edge of the earth plate at a depth not less than 3.25 meter below ground level connected to test point terminal test block by means of copper nuts, bolts, check nuts & washer etc with including necessary earth work and Pre- cast RCC earth pit and cover lifting arrangement and with two coat red paint including marking the chamber as earth pit with writing of inspection test & earth result with black & white paint including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed. note: The rate quoted shall deemed to be inclusive of the followings. a). Excavation & earth work ( filling in, ramming in layers, watering etc as directed)in any type of soil for earth pit of size 1.2 meter X 1.2 meter X 4 meter deep. (b) 20 mm bore mild steel galvanised iron tubing light grade with funnel for watering purpose complete. (c) 40mm bore mild steel galvanized iron tubing light grade for strip protection (d) main cooper earth strip 32 x 6 mm upto 7.5 meter long or upto earth test point (f) Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including screw (g) common salt and charcoal dust in alternative layers of 15 cm up to 90cm above the top of copper plate & one layer of 15cm magnesium sulphate, (approximate quantity of salt 500kg, charcol dust 1000kg, magnesium sulphate150 Kg, 100 Kg soil resistivity improvement powder/ GEL) complete all as specified and directed (h ) Earthing earth testing value should be less than 1.0 Ohm and this should be the sole responsibility of contractor .
M & L for Earth continuity conductor or main earthing lead 4.0 mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead using 20x3mm copper strip with using porcelain insulator fixed to wall or recess or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified and directed.
M & L for replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc (for cable, pole stay manhole etc), in any type of soil and getting out, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed.
Removing excavation material n exc. 50m and deposited where directed at a level not exc. 1.5m above the starting point etc complete all as specified and directed.
M & L for sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. [Note : Punned thickness shall be measured and paid]
M & L for well burnt bricks, laid flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed.
Supply and lay pipe galvanized, “Light grade”, 40 mm dia with all required fittings for protection of cable under road, pavement complete all as directed and specified
Labour only for boring under road, pavement, hard standing by manual/ Mechanical method for inserting with incl light grade GI tubing up to 50 mm dia for cable protection complete all as specified and as directed by Engineer In Charge.
Supply and laying in replacement XLPE insulated PVC inner sheathed, armoured with galvanized steel of wire heavy duty underground cable with aluminium stranded conductor 1100 volt grade of 25 Sqmm 4 Core laid up trenches/duct crossing through pipe/duct or fixed on pole and with suitable size of glands complete and testing complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less ‘than 1.5 meters below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and directed. Note: (i) Item includes the cost of 7.5 meter GI pipe for protection of earth lead.
Supply, erect /install & testing of 20 meter high galvanised mast light shaft in two sections suitable for wind speed as per IS-875 part-3, with raising lowering system pully assembly comprising, double drum winch with luminaire mounting arm, suitable to install 8 nos luminaries in symmetrical arrangement, 6mm dia stainless stell wire rope , trailing cable, connector, integral power tool motor, manual handle junction box , aviation obstruction light, lightning arrester spike and including RCC foundation comprising of the following a) Material & labour for construction of high mast foundation as per manufacturer drawing complete with excavation, returning & filling PCC, RCC, Reinforcement, removal & form work etc including foundation bolts from special steel along with nuts, washers, anchor plates and templates. b) Supply & fixing of outdoor type stand mounted feeder pillar box comprising incomer MCB TPN 32 Amp C series, digital multi meter, timer switch. suitable size contactor for the automatic switching ON/off the luminaries with bypass system, suitable size MCB, contactors for motor operation and raise lower push button. c) Weather proof suitable size and length PVC insulated copper conductor cable from feeder pillar box MCB to winch gear motor with lugs & from feeder pillar box MCB to individual luminary complete. d) Weather proof suitable size and length PVC insulated copper conductor cable from feeder pillar box to high mast luminaries with lugs & MCB complete e) Erection of the high mast pole with the help of suitable tools & plants & fixing in true vertical position. f) Supply & fix single dome aviation obstruction light LED type with all supporting accessories g) Provision of 2 Nos GI pipe earthing with 40 mm dia GI pipe and GI earth strip 25 x 4 mm connection to high mast pole including RCC earth pit chamber and soil excavation complete all as specified and directed by Engr-in-Charge.
S & F for symmetrical beam LED flood light fitting 300 Watt, IP66 protection, 230 V AC with PDC housing and toughened glass and indl LED with secondary optical lens for superior light distribution, Lumen efficiency >120 Lm/W. 4 KV inbuilt and 10 KV external surge protection with driver, complete all as specified and directed.
S & F for galvanized steel body desert cooler, 3 speed single phase motor, propeller 450mm cooler fan capacity of air 3500 cum/ hour, front grill with flexible louvers, side grill with wood wool pad, water tank made out 20 gauge GI sheet and painted with water resistance paint IS 9862, submersible water lifting pump with piano and four way rotary switch for fan motor complete all as specified and directed Make :- Crompton/Khaitan/Bajaj or equivalent as approved by GE.
S & F for weather resistant PVC body desert cooler, 3 speed single phase motor minimum 240 watt capacity and air delivery 8500 cum/ hour, front grill with flexible louvers with removable and cleanable cooling pads submersible water lifting pump with switch and rotary switch for fan motor, minimum 125 Ltr water tank with float valve for auto water filling and lockable heavy-duty wheels, complete all as specified and directed
S & F in new fabrication frame work for desert cooler stand made from angle iron , flat iron, Squar Tube, etc. quality confirming to Fe Gde-E 290 quality with including drilling holes, cutting , welding , bending cold or hot, polishing , in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint etc. complete all as specified and directed.
Supply & fixing PVC connection 15 mm dia 600 mm long with brass fly nut at both ends complete all as specified and directed.
Supplying & fixing 15 mm dia galvanized steel (GI) tubing medium grade with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S & F for stop valves suitable for 15 mm bore of pipe, cast copper alloy screwed down , fancy type, chromium plated high pressure with crutch or butterfly handle , screwed of both ends for unions pipe or for unions complete all as specified and directed.
S & F for brass ball valves suitable for 15 mm bore of pipe, high pressure with polythene float and flynut complete srewed fixed in desert cooler complete all as specified and directed.
Supply, installed and testing for stainless Steel body water coolers, self contained drinking water cooler, electric driven (single phase) having approx storage capacity of 120 litres & nominal cooling capacity of 60 ltr per hours with using non CFC Refrigerant (R-134a) & energy efficient compressor and connecting to electric source with including providing 32 mm drain pipe complete all as specified and directed.
Supply & Fixing for digital voltage stabilizer 15 Amp capacity single phase, naturally air cooled with volt meter, for automatic Low & High Voltage cut-off protection for input voltage of 140 V to 300V and output voltage stabilized between 230 V with accuracy of 2.5% and iron cage for fixing voltage stabilizer to wall complete all as specified and directed.
S & F packaged water purifier wall mountable of capacity 100 ltr per hour with including RO+UV + UF filters, TDS controler and pressure pump etc. suitable for TDS 800 PPM with auto water ON/OFF sensor and fixing accessories complete all as specified and directed. Make :- ION Exchange/Kent/Aquaguard or equivalent as approved by GE.
S & F switch socket combination 2 in 1, 3 pin flush type 240 volt universal complete all as specified and directed
TECH SERVE SOLUTIONS
GITANSH ENGINEERS AND COMPANY
UMIYA BUILDCON
Electricals India
Shree Builders
Ramdev and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .