| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L1 | Accepted-AOC Lowest bidder and quoted reasonable rate | |
| 2 | L2₹33.9 L+₹38,859.40 (1.16%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹36.5 L
EMD Value
₹72,960
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Kargil
Office of GE Kargil, PIN - 908121, C/o 56 APO
TOKEN NO. GE/K-20/2024-25 - SPL REPAIR OF CERTAIN ITEMS IN BLDG NO. P-04 OF 31 PUNJAB AND BLDG NO. T-81 AND T-82 AT 306 FD REGT AT KARGIL UNDER GE KARGIL
2024_MES_662822_1
Token No. GE/K-20/2024-25
Open Tender
Civil Works
Item Rate
180 days
Kargil
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kargil
₹72,960
Yes
Office of GE Kargil
4 Nov 2024
28 Jun 2024
5 Sept 2024
28 Jun 2024
3 Sept 2024
13 Jul 2024
5 Jul 2024
Amount
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed.
M&L for 75mm thick plain cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in plinth protection finishing of concrete even and smooth without using extra cement all as specified and directed.
M & L for chequered cement concrete tiles 300x300x25mm thick with grey cement and pigment and set jointed and pointed in neat cement slurry as in floor over 20 mm thick sreed bed or bedding layer in CM 1:4 complete all as specified and directed
Dismantling of floor hearth and wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises., complete all as specified and directed by Engr-in-Charge.
M&L for ceramic tiles light shade, 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm in floors etc set and joint in neat cement slurry and point in coloured cement to match the shade of tile including 15 mm thick screed bed in CM 1:4, complete all as specified & directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over 15mm thick screed bed or bedding layer in cement mortar 1:6 all as specified and directed.
M&L for cement concrete type C- 1, 1:3:6 (20mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed.
S & F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap bent to curve, with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed.
M&L for preparing previously untreated steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of redoxide primer including preparation of surface.
M&L for preparing old steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed.
Hacking out old broken glass (any thickness,size,quality or description) from wooden frames metal frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads complete all as specified and directed.
S & F 4.8mm thick sheet glass ordinary quality and glazing with oil putty in squares exc 0.5 Sqm in each pane complete all as specified and directed.
Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and directed.
Dismantling of timber scantling fillets,rails,posts,rafters purlins etc under 40 Sq cm in any position as in unframed work all as specified and directed .
S&F for second class soft wood (KAIL) plain fillets area exc 13 & n exc 25 sqcm square,rectangular or triangular in section, clean sawn, secured with nails or brads all as specified and directed.
S&F 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work as in wall/ceiling complete, all as specified and directed by Engr-in-Charge
S&F 9mm thick prelaminated particle board, interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails to timber frame work all as specified and directed.
S&F for second class soft wood (KAIL) plain fillets area exc 3 & n exc 6 sqcm square,rectangular or triangular in section, clean sawn, secured with nails or brads all as specified and directed by Engr-in-Charge.
S&F in repair curtain rails anodised aluminium alloy chromium plated with fixing brackets, stops, rollers, finials etc. complete all as specified.
M&L for applying two coats of oil bound distemper on old plastered surfaces of walls including preparation of surfaces.
M&L for applying two coats of cement based paint on old plastered surfaces of walls including preparation of surfaces.
M&L for preparation of old wooden painted surfaces of any description, not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint complete.
S&F second class soft wood moulding as in cornices, picture rails and the like sectional area n exc 6.00 Sqm cm all as specified and directed.
M&L plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads.sectional area n exc 3.00 Sqm cm all as specified and directed.
S&F sheet glass 3.00 mm thick ordinary quality, and glazing with oil putty in square nexc. 0.50 Sqm each pane all as specified & directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 finishing of surface even and smooth with out using extra cement all as specified.
M&L for preparing new plastered surfaces of wall applying two coats of cement paint all as specified and directed by Engr-in-Charge.
M&L for preparing old plastered surfaces of wall applying one coat of cement paint all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 finishing of surface even and smooth with out using extra cement all as specified.
M&L for preparing new plastered surfaces of wall applying two coat of oil emulsion distemper over a coat of chalk whiting all as specified and directed.
M&L for 75mm thick cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) on floor sub base all as specified and directed by Engr-in-Charge.
M&L for 25mm thick cement concrete 1:2:4 type B-0 (using 12.50mm graded aggregate) on floor sub base all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified
M&L for preparation of old steel surfaces of any description, over 10cm in width or girth,not otherwise described applying one coat of synthetic enamel paint .
M&L for kota stone slab 20-25mm thick mirror polished in riser of steps, skirting, dado and pillar laid over 10mm thick cement plaster in cement mortar 1:4 and jointed with grey cement slurry including rubbing and polishing complete
S&F in repairs harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc
Taking down shutters of any description exc 1 sq. m but nexc 2 sq m each all as specified and directed.
S&F second class soft wood (KAIL) plain, framed, panelled shutters (any number of panels), 35 mm thick with panels of 9mm ply BWP commercial type or 12 mm thich of veneered particle board with commercial veneering both faces as in doors, complete all as specified and directed.
S & F butt hinges medium weight cold rolled mild steel of 100mm long
S&F 200mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed
S & F 150mm size mild steel pressed handles, oval type, stove enamelled black
S&F 250mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed
M&L for preparation of old wooden surfaces of any description, not otherwise descri-bed over 10cm width or girth applying one coat of synthetic enamel paint
M&L for prepration of new wooden surfaces of any description, not otherwise descri-bed over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 all as specified.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
S&F second class soft wood 25mm thick clean sawn with butt joints boarding,fixing with nails in any situation (except flooring and skirting)
M & L for Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc.
M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer point controlled by one switch.
M&L for Point wiring for light/fan/bell with FRLS cable of 2.5 sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 2.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches, sockets, for multi 5 pin 5 Amp flush type socket outlet on independent board, complete all as specified and directed.
M&L for Point wiring for light/fan/bell with FRLS cable of 2.5 sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 2.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches, sockets, for multi 3 pin 15 Amp flush type socket outlet on independent board, complete all as specified and directed.
S & F Switch piano flush type 5 Amps, single pole one way.
S & F Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type.
S & F Switch socket combination 2 in 1, 5 and 15 Amps flush type.
M & L of ceiling rose on PVC square blocks surface bakelite 3 terminal complete all as specified and directed.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed.
S & F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed.
S & F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 4 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed.
Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 32 Amp in the MCB DB complete with connection testing Complete all as specified and directed.
Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing Complete all as specified and directed.
Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing Complete all as specified and directed.
Supply and fixing in replacement 240 V 10 KA B curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing Complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
M&L for submain wiring comprising single core, 2 Runs of 4 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC conduit of size min 25 mm dia, ISI Marked and its fittings surface on floor/roof/walls complete including provision of 1X4 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS complete all as specified and directed by Engr-In-charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm×6.0mm thick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipment, including watering arrangement with GI medium grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber CI cover with frame including 15mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata, returning, filling, removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified or indicated including testing on completion. Notes : (i) Earth continuity conductor including protection pipe upto 7.5 meters from earth electrode will be include in unit rate, (ii) Arrangement for earth resistance test should be carried out by the contractor. No extra payment shall be provided for the same.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections of size 2 core 16 Sqmm.
Supply & laying or fixing and testing cross linked polytehylene (XLPE) LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 16 Sqmm 2 core and conforming to IS-7098(Part-I-1988 & as per latest amendments), laid in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles including taking down of existing cable complete all as specified & directed.
Supply and Fix GI tubing light grade 40 mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc. all as specified and as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of soft/lose soil for taking out cable & laying of cable complete all as specified and directed
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning filling, including spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I.
Factory made ISI marked un-reinforced precast cement concrete cable cover class LV, flat of size 250mmx150mmx40mm, laid dry over electric cable for protection all as specified.
Note : Deduction for amount of Rs. 75,658.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract.
M/S TRADE LINK (BID ID -3074329)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .