GE (KH) YOL
GE (KH) YOL, YOL CANTT, HP
Repair/Replacement of LT electric supply network and misc works at Lower Garrison at YOL CANTT
2023_MES_621931_1
GE/Y-57/2023-24
Open Tender
Civil Works
Item Rate
180 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (KH) YOL
₹16,000
Yes
20 Dec 2023
6 Oct 2023
10 Nov 2023
6 Oct 2023
3 Nov 2023
20 Oct 2023
Amount
Dismantling/ taking out old unserviceable cable of any size and removing from site, complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified. Note for Srl item Nos. 02 to 05:- (i) Excavation and earth work, sand cushioning, brick work, pipe, cable cover shall be measured and paid separately. (ii) All XLPE cable connected to any LT panel/bus bar should be proper size of cable gland and thimble including quoted rates.
Excavation in trenches n.exc 1.5 metres wide and n.exc 1.5 metres deep and getting out in any type of soil, all as specified.
Returning filling in including spreading leveling, watering and well ramming in layers n. exc 25cm, all as specified.
Removal of excavated material to be distance n.exc 50m and depositing where directed at a level n.exc 1.5m high from the starting point, all as specified.
Sand cushioning to under ground cables, 8cm thick layer before laying and testing the cable and 15cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I and directed by Engr-in-Charge.
Sub class 'B' bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Laying only retrived bricks as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Mild steel galvanised light grade 50mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
MCCB 4 pole with fixed thermal and fixed magnectic release, 400 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with adjustable thermal and fixed magnectic release, 250 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with fixed thermal and fixed magnectic release, 160 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with fixed thermal and fixed magnectic release, 100 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with fixed thermal and fixed magnectic release, 63 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
Cleaning of installation area from inside and outside by removing bushes, shurbs, grass and other vegetation materials by screaching out earth surface, cleaning the fungus formation and nearby growth of wild vegetation, bushes to a distance of 50 metres away all as specified and directed.
Supply, installation, commissioning and testing bus chamber factory made Outdoor type, CPRI approved, size 0.45mx0.75mx0.4m deep, fabricated out of 3.15mm thick mild steel sheet and vermin proof with neoprene gasket having front opening and locking arrangement mounted on angle iron legs made of angle iron size 40mmx40mmx6mm, 8m long, 0.40 mtrs above GL and 0.40 Mtrs embbeded in PCC 1:2:4 type B-1 using 20mm graded stone aggregate blocks of size 0.30mtrsx.30mtrsx0.50mtrs 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete with 200 Amps rating aluminium bus bar duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and copper cable connection with all incoming and outgoing cable connection with suitable size of lugs and glands including one No MCCB with adjustable thermal and fixed magnetic release of capcity of 125 amps, 415 volt, 25 KA, 4 pole, as per makes mentioned in Appendix 'C'), including led phase indicator for three phase including taking down old unservicable chamber all as specified. Note:- Contractor shall submitt the drawings of bus bar champer showing arrangement of MCCB, cable gallery, Bus bar chambers over all dimensions and marked all items to be incorporated in to LT panel for approval of accepting officer. Engineer-in-charge shall ensure that LT busbar shall be made as per approved Drgs only.
Cable route indicator made out of 2mm thick mild steel of size 20cmx15cm duly coated with two coats of black paint over a coat of red oxide primer duly written the size of HT/LT cable in white paint and welded to equal angle of size 30mmX30mmX3mm, 45cm long and errected in ground in such a way that it is 15cm above ground level and 30Cm below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate of size 15cmx20cmx45xcmm, complete all as specified. Note:- Cost pf PCC and earh work and excavation shall be deemed to be included in unit rate quoted by contractor.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 sqmm, including taking down old wire complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 16 sqmm, including taking down old wire complete all as specified.
Aluminium thimble suitable for 95mm XLPE cable, fixed in repair, complet all as specified.
M&L road cutting for laying of cable or under the road or hardstanding by manual for road crossing for using GI tubing of any size for cable protection, complete all as specified and directed by Engr-In-Charge.
smc engineering company
Dhani Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .