Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹44.6 L+₹7.7 L (20.9%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹46.1 L+₹9.2 L (25.0%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹48.4 L+₹11.6 L (31.4%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹50.3 L+₹13.4 L (36.4%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
COMPREHENSIVE MAINTENANCE OF B/R AND E/M SERVICES AT ZONE D COMPRISING CERTAIN OTM/MD ACCNS OF MED REGT AT MIL STN KANCHRAPARA UNDER GE BARRACKPORE
2023_MES_615804_1
8828/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹80,000
Yes
28 Oct 2023
25 Aug 2023
25 Sept 2023
25 Aug 2023
23 Sept 2023
9 Sept 2023
Amount
PART-I Attending day to day complaints of CARPENTARY WORK for carrying out minor/petty repairs such like tighting of screws/nails, easening/repair of joinery & fittings in the MD and OTM Accns of Zone 'A' comprising Engr Regt and MES Kanchrapara. Note : 1. Materials as reqd shall be obtained from Schedule 'A' Part-II here-in-after. 2. Non attendence/completion of complaint shall be charged compensation @ 1000/- per complaints, however, on justified reason as desired by Engineer-in-Charge outstanding complaints shall be allowed another day for attending and completion without compensation.
Attending day to day complaints of BLACKSMITH for carrying out minor/petty repairs such as welding/shouldering, cliping, reveting, etc incl gates, rolling shutter, collapsible gates etc, in the MD and OTM Accns of Zone 'A' comprising Engr Regt and MES Kanchrapara. Note : 1. Materials as reqd shall be obtained from Schedule 'A' Part-II here-in-after. 2. Non attendence/completion of complaint shall be charged compensation @ 1000/- per complaints, however, on justified reason as desired by Engineer-in-Charge outstanding complaints shall be allowed another day for attending and completion without compensation.
Attending day to day complaints of PLUMBING for carrying out minor/petty repairs in the MD and OTM Accns of Zone 'A' comprising Engr Regt and MES Kanchrapara. Note : 1. Materials as reqd shall be obtained from Schedule 'A' Part-II here-in-after. 2. Non attendence/completion of complaint shall be charged compensation @ 1000/- per complaints, however, on justified reason as desired by Engineer-in-Charge outstanding complaints shall be allowed another day for attending and completion without compensation.
Attending day to day complaints of MASON for carrying out minor/petty repairs in the MD and OTM Accns of Zone 'A' comprising Engr Regt and MES Kanchrapara. Note :- 1. Materials as reqd shall be obtained from Schedule 'A' Part-II here-in-after. 2. Non attendence/completion of complaint shall be charged compensation @ 1000/- per complaints, however, on justified reason as desired by Engineer-in-Charge outstanding complaints shall be allowed another day for attending and completion without compensation. (NOTE for Item No. 1.00 to 4.00 : (i). Quotated rates shall incl supply of each and every tools, machines, welding rods, gas, nails, screws, etc as essential for tradesmen for attending complaints. (ii). Rates for attending complaint shall be of unremitting services incl Holidays and Sundays. (iii). Rates shall incl appointment of 01 attender/supervisor by the contractor to monitor each and every complaints and maintenance work carried out. (iv). Attender shall be provided with Smartphone to be kept in MES Complaint cell with Whatsapp facility to receive and feedback of complaints from/to users. (v). Complaints shall be recd and registered in Complaint Register from 8:30 hrs to 4:30 hrs accordingly services shall be accounted for 8 Hrs daily. (vi). The rate of this item are included for attending & completing of complaints only. (vii). The complaints shall be attend and defects shall be rectified within 08 Hrs commencing from date and time of notifing the complaint, failing which a penaulty Rs. 1000 per complaint shall be leived/imposed on the contractor and recovery shall be made from his dues. (viii). Contractor shall be arrange suitable T&P including necessary ladder and scaffolding for approach and safety measures to make it functional complete all as specified and directed. The rates for which are deemed to be included in the quoted rate. (ix). Contractor or his rep will report daily at 08.30 Hrs at complaint cell/MES office for collection of complaint from the concerned Engr-in-Charge, in case after checking, attending and find the defects, if it is not possible to be rectify the defects within 08 Hrs, the fact shall be brought to the notice of Engr-in-Charge by the contractor/his rep immediately. If Engr-in-Charge satisfied with contractors view, no recovery will mede on this account, descretion of Engr-in-Charge shall be final and binding. (x). The contractor/Supervisor should be possession of moble and two wheeler for ease of communication and mobility. (xi). The contractor will maintain complaint docket/complaint slip for each complaint. After rectification of fault/complaint on complaint slip duly signed by JE/MES rep and the same will be enclosed with RAR/Final Bills. (xii). The rates to be inclusive of note No. (i) to (xi) in the quoted rate)
PART-II Supply only Cement ordinary portland, portland pozzolana or portland slag complete all as specified and directed.
Supply only 20mm Graded crushed stone aggregate complete all as specified and directed.
Supply only 12.5mm Graded crushed stone aggregate complete all as specified and directed.
Supply only fine aggregate (sand) complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed.
Supply only subclass Bricks; locally available best quality , sub-class ‘B’ designation 75 complete all as specified and directed.
Supply only Neoprene/ EPDM rubber gasket complete all as specified and directed.
Supply only 2nd class hardwood Timber in clean sawn scantlings complete all as specified and directed.
Supply only 20mm thick 2nd class hardwood, boarding, width n exc. 20cm complete all as specified and directed.
Supply only 30-40mm thick 2nd class hardwood, boarding, width n exc. 20cm complete all as specified and directed.
Supply only Mild steel in flat, round or square bars, in available lengths, grade Fe 410-W (Gde-E- 250) quality- A complete all as specified and directed.
Supply only Structural steel, rolled section such as joist, beam, channel, angle, tee, in available lengths, grade Fe 410-W (Gde-E- 250) quality- A complete all as specified and directed.
Supply only Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes, grade Fe 410-W (Gde-E- 250) quality- A complete all as specified and directed.
PART-III Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and directed. (Note for Item No. 18.00 & 19.00 - Rate shall be deemed to be include for cutting holes/demolition of masionry walls etc for taking down chowkats and making good the damaged surfaces).
Taking down of shutter of any description exceeding 1 Sqm but not exceeding 2.0 Sqm each complete all as specified and directed.
Taking down of shutter of any description not exceeding 1 Sqm each complete all as specified and directed.
Resecuring or easing and adjusting without taking down the shutter of size execeeding 1 Sqm and not exceeding 2 Sqm complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards, any thickness including cover fillet complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
S&F of 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (two panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No. 178 complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification & drawing as mentioned in SSR Part-II (2020), Section 8, Page No.174 complete all as specified and directed.
S&F of 35 mm thick flush door shutters (factory made) solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
S&Fof 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made) for doors and windows , open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, Section-8, Clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
M&L for brick work with subclass 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting exceeding 10 cm but not exceeding 20cm girth complete all as specified and directed.
S&F of Pressed steel frames (Factory made) for doors size 105 mm x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including filing of concrete (1:3:6) type C-0 using 12.5mm aggregate after applying 02 shop coats of bituminous paint to back of chowkhats complete all as specified and directed.
S&F of Pressed steel frames (Factory made) for doors size 125 mm x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including filing of concrete (1:3:6) type C-0 using 12.5mm aggregate after applying 02 shop coats of bituminous paint to back of chowkhats complete all as specified and directed.
S&F 25mm thick solid PVC composite sheet, prelaminated on front side and plain matching dark shade laminated background as in Cubboard flush shutters, fixed with and incl SS flush screws incl necessary cutting for reqd shape, rebate, hinges, hooks, etc and fixing only of self closing hinges, wall hanging hooks, magnetic locks, handles, etc complete all as specified and as directed. (Note :- Necessary Hinges, hooks, handles and locks shall be measured and paid separately as' Supply Only')
S&F 18/19mm thick solid PVC composite sheet, prelaminated on front side and plain matching dark shade laminated background as in kitchen cabinet shutters, backing, sides, top/bottom, etc, fixed with and incl SS flush screws incl necessary cutting for reqd shape, rebate, hinges, hooks, etc and fixing only of self closing hinges, wall hanging hooks, magnetic locks, handles, etc complete all as specified and as directed. (Notes:- (i) Necessary hinges, hooks, handles & locks shall be measured & paid separately as 'Supply Only' under relevant item. (ii) Labour charges for 'supply only' items are deemed to be included with quoted rates)
Supply only heavy duty Slim Nickel plated Stainless steel magnetic catch (L shape) with strong earth magnet, size 11mm x 35mm x 4mm complete all as specified and directed.
Supply only heavy duty stainless steel slip on hinges, self closing type with opening full overlay or 105°, suitable for 25mm thick shutter of maximum size 850mm x 550mm complete all as specified and directed.
Supply only ergonomically designed powder coated Aluminium anodised handle, finger pull type, suitable for 19mm thick shutter, size 14mm x 43mm complete including finish complete all as specified and directed. (Notes for item No. 40.00 to 42.00 :- Material for Item No. 40.00 to 42.00 to be incorporated in Item No. 38.00 & 39.00 here-in-before)
M&L of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for 75mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S&F for 100mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S&F of Aluminium wire cloth, expanded mesh type, 0.45-0.56mm nominal dia of wire and average width of aperture 1.36-1.40mm and fixed with aluminium wire staples, nails, screws, beads, etc in wooden/metal joinery as required.
S&F in repairs of Aluminium wire cloth, expanded mesh type, 0.45-0.56mm nominal dia of wire and average width of aperture 1.36-1.40mm and fixed with aluminium wire staples, nails, screws, beads, etc in wooden/metal joinery as required. (Note : Rate shall include hacking out old wire cloth incl beads, etc and supply and fix new wooden beads where reqd.)
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section (as per IS-204 (Part 2) : 1992) and fixed complete all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section (as per IS-204 (Part 2) : 1992) and fixed complete all as specified and directed.
S&F of 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type (as per IS-208 : 1996) complete all as specified and directed.
S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 140mm) complete all as specified and directed.
S&F in repairs of aluminium extuded body door closer hydraulically regulated designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kg as fixed complete all as specified and directed.
S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B weight of section frame 1.248Kg/m and shutter section weight 0.547 kg/m jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 5.0mm nominal thickness, aluminium wire cloth 0.45 mm dia and average width of aperture 1.4mm, aluminium alloy handles etc complete all as specified and directed. (Note : Rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc.)
S&F powder coated anodised aluminium ventilator with fixed aluminium frame of size 65x40x1.98mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be approved with 4mm thick pin head glass and remaining protion to be ouvered using 4mm thick pinhead glass and louvered porition covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading, and make completed all as specified and directed. (Note : Rates shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc.)
S&F of steel windows with side hung shutters (glazed ) including box type hinges with steel handle, steel peg stay, complete with glazing bars, dovetailed or welded to receive wire mesh/glass complete all as specified and directed.
S&F of steel windows with side hung shutters (glazed ) including box type hinges with steel handle, steel peg stay, complete without glazing bars, dovetailed or welded to receive wire mesh/glass complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and ditected.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for 20-25mm thick machine cut cudappah stone slab flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15 mm thick cement screed bed in cement mortar (1:6) after and including demolished of stone slabs or tiles of any description complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 8 to 10 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
Ditto of Item No.62.00 here-in-before but in skirting over including a backing coat of 10mm thick rendering in cement mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 300 mmX7 mm thick or equivalent set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:4) complete all as specified and directed.
M&L for 18-20mm thick Mirror polished, high gloss finish Granite (absolute Jet Black) work in steps, jambs & soffits of chowkhat (incl necessary pasting), pillars, window-cills, basin platforms, urinal partitions and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl necessary cutting for sunk basin/sink, making holes for fixing hinges, door bolts, etc 15mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishescomplete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of chalk whitening on newly plastered wall surfaces after preparation of surfaces complete all as specified and directed.
M&L for applying one coat of dry distemper white or tinted on old plastered wall surfaces after preparation of surfaces complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane including hacking out old broken glass (any thickness and size, quality or description from steel/wooden frame etc) fixed with putty or beads complete all as specified and directed.
S&F of 4.8mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares exceeding 0.50 sqm each pane including hacking out old broken glass (any thickness and size, quality or description from steel/wooden frame etc) fixed with putty or beads complete all as specified and directed.
S&F of 4mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane including hacking out old broken glass (any thickness and size, quality or description from steel/wooden frame etc) fixed with putty or beads complete all as specified and directed.
S&F powder coated anodised aluminium snap grid frame work for false ceiling, Size of grid 605 x 605mm using Main/Cross Bulbed tees - Tapered head (Web : 25mm Flange : 38mm) of wt not less tham 0.249 kg/m and Equal angle of size 25mm of wt not less than 0.196 kg/m, complete all as specified and directed by the Engr-in-Charge.
M&L for 4mm thick Non asbestos fibre cement building boards (E-board) fixed or laid/ inserted to Aluminium framework with screws complete all as specified and as directed.
S&F of 20mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass CPVC fittings and cutting grooves, filled with Cement mortar(1:6) complete all as specified and as directed.
S&F of 25mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass CPVC fittings and cutting grooves, filled with Cement mortar(1:6) complete all as specified and as directed.
S&F of 50mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass CPVC fittings and cutting grooves, filled with Cement mortar(1:6) including taking down old unserviceable pipe complete all as specified and as directed.
S&F in repairs of brass chromium plated Bib taps (suitable size for 20mm outer dia CPVC pipe) concealed type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F of in repairs of brass chromium plated Bib taps (suitable size for 20mm outer dia CPVC pipe) nozzel with flange for connecting delivery pipe of washing machine complete all as specified and directed.
S&F in repairs of brass chromium plated angular stop cock with flange (suitable size for 20mm outer dia CPVC pipe) concealed type complete all as specified and directed.
S&F in repairs of brass chromium plated 2-way angular stop cock with flange (suitable size for 20mm outer dia CPVC pipe) concealed type complete including taking down old unserviceable stop cock complete all as specified and directed.
S&F in repairs of 15 mm bore stop valve, fancy type chromium plated with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs of 15mm dia pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F in repairs of Brass CP Sink Mixer with movable neck, fixed to wall, for mixing hot & Cold water screwed down for iron pipe and fixed and joint with adhesive, taflon tape, etc complete including taking down old CP Pillar tap complete all as specified and directed.
S&F in repairs of 32mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc. with long screwed shanks & fly nuts, flanged end bedded in red lead cement & other end fixed complete all as specified and directed
S&F in repairs of sinks without drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs of vitreous china wash basin, white, flat back, size 550 X 400 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F in repairs of health faucet (ABS) with rubbit cleaning system, with 1.25mtr long easy flexible tube suitable for 20mm outer dia of CPVC pipe and wall hook including making connections & fixed in position complete all as specified and directed.
S&F in repairs of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia suitable for low level cistern fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F in repairs of vitreous china wash down water closet pan (pedestal pattern) white with 'P' or 'S' trap type (excluding flushing cistern & flush pipe) including connection to trap with 110mm PVC (SWR) connection and lip ring & to flushing pipe, anti-syphonage pipe out in with and including white seat cover etc. including making good to floor complete all as specified and directed.
S&F in repairs of vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:4:8) type D2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor complete all as specified and directed.
S&F in repairs of 15 mm dia PVC connection pipe of length 600 mm with PTMT nuts complete all as specified and directed.
S&F of 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 20mm dia ball valve high pressure of PTMT (minimum weight 210 gms) including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F of 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 25mm dia ball valve high pressure of PTMT (minimum weight 455 gms) including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
Taking up or down old unserviceable steel tubings including connections and removing from site for 15 mm bore pipes complete all as specified and directed.
Taking up or down old unserviceable steel tubings including connections and removing from site for 20 mm bore pipes complete all as specified and directed.
S&F in repairs of wall mixer 3-in-1 system with provision for both hand shower and OH shower complete with 115mm long bend pipe, connecting legs & Wall Flange (without hand & over head shower) complete all as specified and directed.
S&F in repairs of CP wash basin mixer for mixing hot & cold water screw down for iron pipe including necessary connection pipe from stop cock complete all as specified and directed
S&F in repairs of 125mm size brass chromium plated shower roses with arms, swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs of 25mm dia (heavy duty) stainless steel, single curtain rod (wall thickness not less than 1mm) including funnels, brackets, stops etc suitable for single curtain rod, fixed etc complete all as specified and directed.
S&F 125mm long curtain rod side brackets of stainless steel (SS 202), angular or cantilever type fixed to wall with 02 nos screws on each bracket and fitted screws for fixing curtain rod incl stainless steel (SS 202) decorative design plain metal colour nobs (oval/shere shape) with fixing arrangement for curtain rod using a screw complete all as specified and directed.
S&F 20mm gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
PART-IV Disconnecting the electrification and taking down old DBs( any type of vertical load line/TPN/SPN DBs including MCB any type & capacity) and making good to the disturbed surfaces to match the existing surfaces complete all as specified and directed. (Note: Temporary power supply shall be provided by the contractor)
Taking down unserviceable submain wiring aluminium/copper conductor etc and making good the disturbed surfaces of walls/floor etc matching with the existing surface.
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note for item No. 110.00 to 112.00 : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensured for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.)
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC conduit of size 20mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch
One light point controlled by two 2 way switches.
One ceiling fan point controlled by one switch.
One exhaust fan point controlled by one switch.
One 3 pin socket outlet 5 Amps on the same board.
One bell/buzzer point controlled by one push button
One 3 pin socket out let 5 Amps on the independent board.
All as per Item No.112.00 above but 2.5 Sq mm multi stranded copper conductor with 2.5 Sq mm copper earth continuity wire connected to earth duly complete for one 15/16A Socket on Independent board all as specified and as directed by EIC.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC casing caping of suitable size(heavy duty) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as sunken box, top cover , blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch.
One light point controlled by two 2 - way switches.
One ceiling fan point controlled by one switch.
One exhaust fan controlled by one switch.
One 3 pin socket outlet 5 Amps on the same board.
One bell/buzzer point controlled by one push button
One 3 pin socket out let 5 Amps on the independent board.
All as per Item No.114.00 above but 2.5 Sq mm multi stranded copper conductor with 2.5 Sq mm copper earth continuity wire connected to earth duly complete for one 15/16A Socket on Independent board all as specified and as directed by EIC.
S&F in repair of surface and wall mounted LED batten 18/20W polycarbonate housing with integrated electronic driver PC Batten ,100 Lumen(4 Feet long) complete all as specified and directed
S&F in repair of surface and wall mounted LED batten 9/10W with integrated electronic driver (2 Feet long) complete all as specified and directed .
S&F of fixing switch frame proof rotory type with termination box in LM6, 16A single pole, 250V complete all as specified and directed .
S&F in repair of 15W LED white/warm ,Round/Square surface mounted downlighter including suitable driver & all accessories to fixed on Ceiling/Wall complete all as specified and directed.
S&F in repair of 15W LED White/Warm, Round/Square recessed mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement complete all as specified and directed.
S&F in repair of LED fittings 1x16/20 watts flame proof type FLP-WP made of aluminium alloy LM6, with all accessories LED lamp rod, pre wired and including connecting up copper conductor cable with suitable size complete as specified and as directed.
S&F in repair of LED post top light 30/35 Watt as suitable at site including all accessories complete as specified and as directed.
S&F in repair of LED post top light 14/15 Watt as suitable at site including all accessories complete as specified and as directed.
S&F in repair of Decorative City 1/3 or equivalent wall light fixture made up of polycarbonate suitable for lamp (B22) including suitable size LED Bulb etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in repair of LED luminaire 600 mm x 600 mm, 40 watts, 220 Volts, AC, recessed/surface,white /warm type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size compete including taking dwon old unserviceable light fitting complete all as specified and directed.
S&F in repair of LED Flood Light 100W of any colour as required made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection system complete all as specified and directed.
S&F in repairs of LED light fitting 1x9W/1x10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including fixing arrangements at any hight with nuts, screws and washers and connected to ceiling rose complete all as specified and directed. (Make: Philips Cat No. WT202WLED6SCWPSUS2PC/SURYA Cat No. SLE BH 10W/Bajaj Cat No. BIBWP10W LED or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of 35/36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable including taking down old unserviceable street light fittings complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED/Philips Cat No. BRP052 LED 036 CW HP SLAF G SI PSU GR or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
Supply, fabricated and and fixing of building security light bracket made out of GI pipe 1.0 Mtr long, 32 mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer and taking down old unserviceable bracket and making good the distrubed surface of the wall all as specified and as directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F in repairs of angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F of stepped type (0-4/5 step) piano type electronic fan regulator 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F in repairs of stepped type (0-4/5 step) piano type electronic fan regulator 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F of call bell, AC, 230 Volts single pole, ding dong type ISI marked complete all as specified and directed.
S&F in repairs of call bell, AC, 230 Volts single pole, ding dong type ISI marked complete all as specified and directed.
S&F of bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete all as specified and directed.
S&F in repairs of bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F in repairs of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F in repairs of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of switch piano, flush type, single pole, two way, 5/6 Amps, 240Volts, AC, ISI marked complete all as specified and directed.
S&F in repairs of switch piano, flush type, single pole, two way, 5/6 Amps, 240Volts, AC, ISI marked complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 to 15/16Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F in repairs of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 to 15/16Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F of switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F in repairs of switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F of ceiling rose, surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F in repairs of ceiling rose, surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F in repairs of modular switch 6/10 Amps, single pole, 1way, 1 module, 240V, AC, ISI marked complete all as specified and directed.
S&F in repairs of modular switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI marked complete all as specified and directed.
S&F in repairs of modular socket 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F in repairs of modular socket 16 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F in repairs of modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F in repairs of modular blank plate, 1 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular type white cover plate with frame 1/2 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular type white cover plate with frame 3 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular type white cover plate with frame 4 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular type white cover plate with frame 6 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular type white cover plate with frame 12 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular metal flush box 1/2 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular metal flush box 3 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular metal flush box 4 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular metal flush box 6 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of modular metal flush box 12 module as per site complete all as specified and directed by Engineer-in-charge.
S&F in repairs of MS Box in concealed of any type and any size complete all as specified and directed.
S&F in repairs of PVC hylam sheet 3mm thick top cover of size 250 x 150 x 3 mm all as specified and directed by Engineer-in-charge.
S&F in repairs of PVC hylam sheet 3mm thick top cover of size 150 x 100 x 3 mm all as specified and directed by Engineer-in-charge.
S&F of vertical load line in sheet metal enclosures MCCB TPN DB's with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooing , IP-43 , TPN 4 way with 200 amps rated busbar, 440 volts, as per IS-8623 and making good the disturbed surface of wall and match with the existing surface compelte all as specified and directed. ( Note- MCCB 3 pole 63 amps as main incomer will be measured and paid separately)
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200 Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 80 4 way /L&T Cat No. DBTPN004GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,SPN distribution board 2 way suitable for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200 Amps, MCB SPN/SP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed.
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 4 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 20 4 way /L&T Cat No. DBSPN004GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat as complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way /L&T Cat No.DBSPN008GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 12 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 200Amps, MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 22 12 way /L&T Cat No. DBSPN012GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F in repairs of MCCB 3 pole , 415V fixed type of capacity 63-100 Amps, 16 KA, housed with Vertical load line DB and connecting under ground cable as a main incomer to the building complete all as specified and directed.
S&F in repairs of MCCB 4 pole , 415V fixed type of capacity 100-125 Amps, 25 KA, housed with Vertical load line DB and connecting under ground cable as a main incomer to the building complete all as specified and directed .
S&F MCBs SPN 32 Amps, 240 Volts, 50Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by EIC.
S&F in repairs of MCBs SPN 32 Amps, 240 Volts, 50Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by EIC.
S&F of MCB, SP, 6 Amps to 32 Amps , 'B' series, 240 Volt, 10KA, 50 Hz, ISI marked including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by EIC.
S&F in repairs of MCB, SP, 6 Amps to 32 Amps , 'B' series, 240 Volt, 10KA, 50 Hz, ISI marked including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by EIC.
S&F in repairs of MCB, SPN, 40 to 63 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
S&F of MCB TPN 40 to 63 Amps,415 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and as directed.
S&F in repairs of MCB TPN 40 to 63 Amps,415 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and as directed.
M&L for earthing with glavanised steel earth plate electrode of size 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old earthing complete all as specified and directed. (Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
S&F in repairs of sheet metal enclosures with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 Volts complete all as specified and as directed .
S&F for exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 volts, 50 Hz, 1200 RPM, copper winding of sweep 250 mm complete including taking down old unserviceable fan and deposited to MES store yard complete all as specified and directed.
S&F of wall fan 400mm sweep mounting on wall copper winding with plastic body covering 230 volts, 50Hz complete all as specified and directed.
S&F of ceiling fan 1200 mm copper winding 230 volts, 50Hz including down rod , clamp for fixing and MS hooke if required for proper fixing,complete all as specified and directed.
M&L for disconnecting electric supply, taking down fan, cealing cable ends, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan any size from existing position and bringing to AGE E/M store yard for cleaning all dusts, oiling, greasing complete all as specified and directed.
Hanging only ceiling fan complete connecting up including provision of cable, MS hooke if required from ceiling rose or connector to fan complete all as specified and directed.
M&L single phase exhaust fan motor only of 380/450mm sweep having 1400 RPM speed, copper wound, AC, 230 Volts, 50 Hz, ISI marked complete with all standard accessories including taking down old unserviceable motor complete all as specified and directed.
M&L single phase exhaust fan motor only of 300mm sweep having, copper wound, AC, 230 Volts, 50 Hz, ISI marked complete with all standard accessories including taking down old unserviceable motor complete all as specified and directed.
M&L for exhaust fan blade metal type suitable for 300mm exhaust fan or as per site requirement complete including taking down old unserviceable blade complete all as specified and directed.
S&f of exhaust fan frame metal type of size up to 300mm sweep as per existing size suitable for any make including bolts, nut, if required etc complete including taking down old unserviceable one complete all as specified and directed.
M&L for exhaust fan blade suitable for 380/450mm exhaust fan or as per site requirement complete including taking down old unserviceable blade complete all as specified and directed.
S&f of exhaust fan frame metal type of size 380/450mm sweep as per existing shaft size suitable for any make including bolts, nut, if required etc complete including taking down old unserviceable one complete all as specified and directed.
Taking down , checking and servicing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease , replacement of worn out nut bolt, rubber real bush gun metal ball bearing,Clamp, capacitor split and reassembling the fan complete including testing after assembling and connecting to electric system complete all as specified and as directed by Engr-in-Charge. (NOTE:- Rates of bearing, capacitor,downrod,clamp, blades & painting will be paid seperately in the concerned item of schedule.)
All as per Item No. 197.00 here in before but for exhaust fan of 250 to 450 mm sweep complete all as specified and directed.
Taking down carefully AC single phase 220/230volt ceiling fan 1200/1400mm sweep single phase complete at site for rewinding ,rewinding with copper wound and replacement of unserviceable parts i.e Capacitor, PVC connector, MS galvanised check nut, ball bearing, rubber pads, PVC strip clamps including servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin rubber packing and rubber seal etc including testing after assembling and connecting to electric system complete all as specified and as directed by Engr-in-Charge. (Note : Rates of replacement of any unserviceable parts except Rewinding mentioned above required to make the fan in serviceable condition are paid under separate item.)
All as per Item No. 199.00 here in before but for exhaust fan of 200 to 300 mm sweep complete all as specified and directed.
All as per Item No. 199.00 here in before but for exhaust fan of 380/450/600 mm sweep complete all as specified and directed.
All as per Item No. 199.00 here in before but for exhaust fan of 350 to 600 mm sweep complete all as specified and directed.
S&F in repairs of capacitor 2.5 MFD + 5%, 220/230 volts AC, 50Hz complete all as specified and directed.
S&F in repairs of capacitor 3.15 MFD + 5%, 220/230 volts AC, 50Hz complete all as specified and directed.
S&F Electric cable PVC insulated with copper conductor (flexible cable) round sheathed 1100 volts confirming to IS-694 of size-0.50 Sqmm twin core for connecting fan to electric system including taking down old unserviceable cable complete all as specified & directed.
Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes to ceiling fan of 1200/1400mm sweep of any make complete all as specified and directed.
Taking down and Spray painting to AC ceiling fan 1200/1400mm sweep any make complete to motor assy, blades with ISI marked white/brown synthetic enamel paint as approved by Engr-in-Charge after preparation of surface including filling cavities with filler, complete and refixing the same in existing location after painting complete all as specified and as directed by Engr-in-charge.
All as per item No. 207.00 but for exhaust fan 300mm complete all as specified and directed.
All as per item No. 207.00 but for exhaust fan of size 450/600 mm sweep complete all as specified and directed.
M&L in repairs of Canopies (set of 2)for AC ceiling fan of size 1200/1400mm sweep for any make of fan complete all as specified and directed.
S&F in repairs of down rods for ceiling fan 1200/1400mm sweep of suitable size long duly painted with white synthetic enamel paint complete all as directed by Engr-in-charge
S&F in repairs of clamp suitable for ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as directed by Engr-in-Charge.
Takingout old unserviceable louvers of any type upto G+1 storey, S&F exhaust fan louver of size 300/350 mm sweep made out of MS sheet complete includng making good the disturbed surface of wall both inner and outer side and match with the existing all as specified and directed. (NOTE- Contractor will make all arrangement of safety devices and necessary T&P, and department will not be held responsible for any kind of accident and damage caused to man and machinary.)
Taking out old unserviceable louvers of any type at bldg above G+1 and upto G+3 storey, S&F exhaust fan louver of size 300/350 mm sweep made out of MS sheet complete includng making good the disturbed surface of wall both inner and outer side and match with the existing all as specified and directed. (NOTE- Contractor will make all arrangement of safety devices and necessary T&P, and department will not be held responsible for any kind of accident and damage caused to man and machinary)
Taking out old unserviceable louvers of any type upto G+1 storey, S&F exhaust fan louver of size 450 mm sweep made out of MS sheet complete includng making good the disturbed surface of wall both inner and outer side and match with the existing all as specified and directed. (NOTE- Contractor will make all arrangement of safety devices and necessary T&P, and department will not be held responsible for any kind of accident and damage caused to man and machinary.)
M&L in repairs fan blade (set of 03) suitable for 1200 mm sweep all as specified and as directed by Engr-in-Charge.
S&F in repairs of Ball bearing suitable size of ceiling fan any type and size complete all as specified and as directed.
S&F in repairs of Ball bearing suitable size of exhaust fan any type and size complete all as specified and as directed.
Taking down carefully storage type water heater of 25/35 litres capacity (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes, stop valve, non return valves etc leakage arresting of inner copper/steel tank by weilding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washetrs etc refixing the same in position reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying out testing for proper functioning all as directed by Engineer-in-Charge for geyser of any capacity. (Note : Non return valve ,stop valve, bib tap/ PVC connection /Copper connections cable , glass wool element, thermostat , storage tank, geyser assembly , indicator etc shall be measured separately.)
Supply and replace heating element 1.5/2.0 Kilo Watt Capacity of storage type water heaters of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer-in-Charge .
S&F of thermostat suitable for 25/35/50 litre capacity storage type water heater as per sample including removal of old unserviceable ones all as specified and as directed by Engineer-in-Charge.
S&F non return valve of suitable size for geyser repair including removal of old unserviceable ones all as specified and as directed by Engineer-in-Charge.
S&F in repairs of Geyser SS assembly/aperture plate for housing Heating element, 6/8/9 Holes type for 50/35/25 ltr for storage type Geyser , as per sample complete all as specified and directed.
S&F in repairs of Geyser Copper tank for 35/25 ltr for storage type Geyser with MS collar, as per sample all as specified and directed.
S&F in repairs of stainless steel 18 Inch long and 15 mm bore flexi connection pipe for both hot and cold water with stainless steel braided suitable for storage water geyser complete all as specified and directed.
S&F in repairs of glass wool for 50/35/25 ltr storage type Geyser , as per sample complete all as specified and directed.
M&L in repairs of polycarbonate Plug top 15 Amps, 3 pin 240 Volts complete all as specified and directed.
M&L for indicator lamp suitable for 25/35/50 Ltrs geysers as per existing sample in green and red colour including taking down old unserviceable one complete all as specified and as directed by Engr-in-Charge.
S&F of 25mm GI tubing medium grade with all fitting and fixed complete to walls and ceiling or laid in floors of size including all accessories such as tee, bend, elbow, and union etc including taking down the existing pipes and connections including making good to disturbed surface of wall and match with the existing one complete all as specified and directed.
S&F in repairs of anchor bolt of size 10mm dia and 100mm long bolt including, nut, washer for mounting the geyser complete all as specified and directed.
S&F 25mm dia gunmetal gate valves with iron wheel head, screwed both ends for iron pipes after taking down old unserviceable gate valve complete all as specified and directed.
S&F electronic meter temper proof LCD display with polycarbonate cover, 230 Volts, 10-60 Amps, accuracy class-I, confirming to IS-13779, IP-54, with parameters to show date, time, current reading, load, PF, Voltage and KWH complete all as directed by Engr-in-Charge.
S&F electronic meter temper proof LCD display with polycarbonate cover, 415 Volts, Three phase, 10-60 Amps, accuracy class-I, confirming to IS-13779, IP-54, with parameters to show date, time, current reading, load, PF, Voltage and KWH complete all as directed by Engr-in-Charge.
S&F exhaust fan steel body, heavy duty, 4 blade type, double ball bearing , AC sigle phase, 230 volts, of size 300 mm sweep with blades and frame and louvers complete all as specified and directed.
S&F in repairs of PVC rectangular block for mounting switch/socket/MCB DB's with 3mm thick plastic laminated sheet cover of size 200x150x50mm deep complete all as specified and directed.
S&F in repairs of PVC rectangular block for mounting switch/socket/MCB DB's with 3mm thick plastic laminated sheet cover of size 175x100x50mm deep complete all as specified and directed.
M&L in repairs of 40mm bore GI pipe (Light grade) fixed with wall suitable for hanging of ceiling fan of 1200mm sweep, cable along pole including necessary cutting hole in brick/stone wall and making good the same with PCC 1:2:4 type C-1 as required complete all as specified and directed. (Note : Rate quoted deemed to be included for GI pipe 40mm bore fixed on wall for hanging ceiling fan includes making holes with PCC filling by the contractor).
Taking down electric meter carefuly from the meter box and re-fixed the same in the/new location all as specified and as directed.
Taking down old unserviceable existing service/UG cable all as specified and as directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium standed conductor 1100 volts grade, cross-sectional area 16 Sqmm, 2 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable cable complete all as specified and directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium standed conductor 1100 volts grade, cross-sectional area 16 Sqmm, 4 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable cable complete all as specified and directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium standed conductor 1100 volts grade, cross-sectional area 35 Sqmm, 3.5 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable cable complete all as specified and directed.
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 115mm x .75mm laid dry flat complete all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
Boaring holes horizontally under road without damaging the surface of road(minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of dia not exceeding 100 mm dia for passing of UG cable all as specified and as directed.
INDUSTRIAL CONSTRUCTION
CHATTERJEE ENTERPRISE
M/s S K SHARMA
NANDY ENTERPRISE
M/S KARTICK CHANDRA CHAKRABORTY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .