Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAdmitted-Finance | ₹1.8 L | L1 | Admitted-Finance |
| 2 | L2₹1.8 LAdmitted-Finance | ₹1.8 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VG CONSTRUCTION L2 | VGM CONSTRUCTIONS L1 |
|---|---|---|---|---|---|
| 1.00Replacement of Ceiling Plastering with two Coat Putty for PUE School Building in Natarajapuram in Natarajapuram Panchayat. | |||||
| 1.01 | Chipping of concrete and roughening the surface | 93.03 | cum | 55 ₹5,116.65 | 43 ₹4,000.29 |
| 1.02 | Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHA
certified Waterproofing coating with flutyne protection
technology, single component, cold applied, water
based acrylic and UV resistant water proofing
treatment to the Existing Roof having Tile or any
non-porous surface applied @ 1.5 l/m2 in 2 coats to
achieve 1mm DFT, having tensile strength with 45
gsm glass fibre mesh 4N/mm2 confirming to ASTM D
412; Elongation at break ≥ 300% and Crack bridging
ability up to 3mm, SRI Index 106 as per ASTM E 1980-
01, Water permeability @5 bar – Nil as per EN12390
- 8:2019, including surface preparation, priming the
surface with single component high-performance
waterborne tile primer which is suitable for non -
porous surface at a rate of 0.14 L/m2 and spreading 45
gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwiched
between the first and second coat completely as per
specification. The finished cost to include surface
preparation, making coving at Junction, treatment of
cracks completely as per specification. | 96.85 | sqm | 970 ₹93,944.50 | 953 ₹92,298.05 |
| 1.03 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc | 103.44 | sqm | 320 ₹33,100.80 | 308 ₹31,859.52 |
| 1.04 | Oilbound Distember two coats over priming coat with white cement. | 103.44 | sqm | 220 ₹22,756.80 | 205 ₹21,205.20 |
| 2.00 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package} | 1 | GST Amount (in Rupees) | 27,885 ₹27,885 | 26,885 ₹26,885 |
Tender Value
₹1.9 L
EMD Value
₹2,000
Closing Date
6 Mar 2026, 3:00 pmClosed
BDO Thiruverumbur
BDO office Thiruverumbur
Replacement of Ceiling Plastering with two Coat Putty for PUE School Building in Natarajapuram in Natarajapuram Panchayat
2026_RDTN_670704_1
A2/2692/2026
Open Tender
Civil Works
180 days
BDO Thiruverumbur
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹2,000
Yes
7 Mar 2026
5 Mar 2026
6 Mar 2026
5 Mar 2026
6 Mar 2026
5 Mar 2026
Replacement of Ceiling Plastering with two Coat Putty for PUE School Building in Natarajapuram in Natarajapuram Panchayat.
Chipping of concrete and roughening the surface
Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHA certified Waterproofing coating with flutyne protection technology, single component, cold applied, water based acrylic and UV resistant water proofing treatment to the Existing Roof having Tile or any non-porous surface applied @ 1.5 l/m2 in 2 coats to achieve 1mm DFT, having tensile strength with 45 gsm glass fibre mesh 4N/mm2 confirming to ASTM D 412; Elongation at break ≥ 300% and Crack bridging ability up to 3mm, SRI Index 106 as per ASTM E 1980- 01, Water permeability @5 bar – Nil as per EN12390 - 8:2019, including surface preparation, priming the surface with single component high-performance waterborne tile primer which is suitable for non - porous surface at a rate of 0.14 L/m2 and spreading 45 gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat completely as per specification. The finished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specification.
Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
Oilbound Distember two coats over priming coat with white cement.
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.19 MB
tecbid.pdf
Tender Documents • 0.43 MB
pricebid.pdf
Tender Documents • 0.31 MB
BOQ_806020.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid