Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC | L1 | Accepted-AOC Sri Sarat Mohanta stands 1st lowest Rs.3705909.00 | |
| 2 | L2₹37.6 L+₹50,712 (1.37%)Rejected-AOC GORUMAHISANI RAIRANGPUR ODISHSA | MALKANGIRI | ODISHA | 764044 | L2 | Rejected-AOC Sri Sarat Mohanta stands 1st lowest Rs.3705909.00 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not furnshed work experience in similar nature of work within the last five financial year as per DTCN | |
| 4 | Rejected-Technical | - | Rejected-Technical Not furnshed work experience in similar nature of work within the last five financial year as per DTCN | |
| 5 | Rejected-Technical | - | Rejected-Technical Not furnshed work experience in similar nature of work within the last five financial year as per DTCN |
Tender Value
Refer Docs
EMD Value
₹39,100
Closing Date
3 Dec 2020, 5:00 pmClosed
EE RWSS Division Baripada
Near Stadium Field PO Bhanjapur Baripada Mayurbhanj
Retrofitting of Commissioned Rural Piped Water Supply Scheme to village Patalipura in Patalipura G.P. under Betnoti Block in the District of Mayurbhanj under JJM 2020-21
2020_RWSS_64058_2
27/RWSSBPD/2020-21
National Competitive Bid
Civil Works - Water Works
Lump-sum
300 days
Baripada
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
₹39,100
Yes
17 Mar 2021
25 Nov 2020
4 Dec 2020
25 Nov 2020
3 Dec 2020
25 Nov 2020
25 Nov 2020 - 30 Nov 2020
Amount
Supplying all materials , labour , T&P , complete in all respect for Construction / Repair of RCC Roof building pump house and construction of compound wall for pump house and construction of approach road alongwith site Development including laying , testing and commissioning of Rising main & Distribution system pipe line such as HDPE , ASTM , GI pipe lines etc. along with required fittings & specials and construction of Brick masonary Valve chambers, functional house hold tap connection (FHTC) , stand alone (1000ltrs. Capacity) , installation of Chlorination system (1.0 HP capacity injector pump provision with 200ltr capacity PVC double drum) , Cleaning & developing the Production Well, installation of submersible pump with motor in deep Tube well etc. ( Including supply of stand by pump motor ) , internal wiring of pump house , etc. as per detailed scope of work & Technical specification , Quantity of work mentioned in section - 5 and in ( Annexure - A to G) . All materials required shall be supplied by the contractor as per terms and condition of DTCN & all dimentions are as per Annexure and direction of Engineer- in -charge. All work shall be completed in such a manner that all house hold of entire village will get required quantity of drinking water with residual head of 7.00 mtr and residual chlorine of 0.20 mg/ ltr without any leakage in the entire PWS System. (Refer Annexure)
Construction of 70,000ltrs Capacity RCC OHR x 15M Staging- Supplying all materials, Labour, Tools & Plants etc. for soil testing, supply of design,drawing, vetted by State Technical Sanction Agency, Construction, erection, testing and Commissioning etc. of 70,000 Ltrs. capacity with staging height of 15mtr RCC ESR consisting of minimum 6nos RCC columns and circular dome using CC M25, 4nos ISI marked CI sluice valve & Brick masonary valve chambers with RCC Cover slab supplying, fitting & fixing of medium grade GI pipe (Tata/Jindal make) of required dia & length from Container to Sluice Valve Chamber , RCC ladder with G.I. Pipe (Medium class) hand rail at both side (Post - 32mm dia,Top rail - 32mm dia, Bottom rail - 20mm dia) upto dome and around the dome outside of walkway and Alluminiyum ladder inside & M.S. ladder outside the Container, lightning arrester, water level indicator, C.I.Puddle collar, 0.6M dia C.I.Man hole cover - 2 nos at dome, RCC vent cover with brass jally, inside plastering (1:4) with punning & painting with 2 coats epoxy paint suitable for drinking water purposes, out side cement paint two coats including one coat primer etc. all complete as per direction of EIC as indicated below: (i) 100mm dia G.I. pipe of medium grade - 40-50Mtrs for connection from ESR to head works including earth work excavation, laying in trenches and refilling the foundation trenches with excavated materials. , (ii) G.I. pipe of 100mm dia. medium grade with both side flanged - 70-80mtrs (for inlet, outlet, wash out, over flow etc.) (iii) Fitting & fixing of 100mm dia CI flanged sluice valves-4nos, (iv) Sluice Valve Chamber - 4nos as per the detail drawing and design & DTCN, (v) Foundation will be filled with sand upto G.L., then 150mm metalling & 50 mm P.C.C.(1:2:4), (vi) Compacted layers of sand and PCC M10 of thickness 150 mm each to be placed below the footing.
DEEPAK KUMAR MOHAPATRA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .