Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.1 Cr
EMD Value
₹2.1 L
Closing Date
5 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical)
Supply, Installation, Testing & Commissioning of 1.5 Ton Goods Lift and related items at Pathypustak Mandal, G.I.D.C, Sector-25, Gandhinagar. Dist:- Gandhinagar ( Including Civil work) (Second Attempt)
265586
NIT-02 (2025-26) Electrical Sr.No.4
Open
Electrical
Works
Gandhinagar
11 documents required · 10 mandatory · 1 optional
₹3,600
Yes
GUJARAT STATE POLICE HOUSING CORPORATION LTD, Payable at Gandhinagar
₹2.1 L
Yes
16 Jan 2026
16 Jan 2026
16 Jan 2026
5 Feb 2026
16 Jan 2026
NAME OF WORK :- Supply, Installation, Testing & Commissioning of 1.5 Ton Goods Lift and related items at PathyPustak Mandal, G.I.D.C., Sector-
25, Gandhinagar. Dist – Gandhinagar (Including Civil work) (Beneficiary’s Director.Priority N.R.B.2025-26)
STATEMENT SHOWING AT APROXIMATE A QUANTITY FOR THE ITEM OF ABOVE WORK TO BE CARRIED OUT AND APPROXIMATE COST PUT TO THE TENDER FOR
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
1 Excavation for foundation in loose or soft soil upto 1.5 m. depth including sorting out and 131.20 CMT 121.91 Rs. One hundred twentyone & paise ninety
stacking of useful materials and disposing of the excavated stuff upto any Lead and lift. one only
2 Excavation for foundation in loose or soft soil 1.5 m. to 3.0 m depth including sorting out and 81.50 CMT 134.95 Rs. One hundred thirty four and paise ninety
stacking of useful materials and disposing of the excavated stuff upto any Lead and lift. five only
3 Providing and filling rubbles including hand packing and filling interstices with quarry spalls 20.30 CMT 1836.84 Rs. One thousand eight hundred thirty six
behind abutments and between ruturns as directed and paise eighty four only
4 Filling avaliable excavate earth ( excluding rock). In trenches, plinth sides of foundations etc. in 126.50 CMT 135.56 Rs. One hundred thirty five and paise fifty
layers NOt exceeding 20 cms. In depth consolidation each deposited layer by ramming and six only
5 Providing and laying Cement concrete 1:3:6(1cement:3coarse sand :6 Machine crush stone 11.20 CMT 3054.35 Rs. Three thousand fifty four and paise thirty
aggregate 40mm nominal size) and curing etc complete excluding cost of form work in (A) five only
Foudation and plinth
6 Providing & laying controlled cement concrete M 250 including finishing smooth with curing 43.00 CMT 4674.84 Rs. Four thousand six hundred seventy four
complete including cost of formwork but excluding the cost of reinforcement in Foundation and paise eighty four only
Footing and mass concreteRates Are Inclusive Of Providing & Mixing Plastisizer Of Approved
Make & In Proportion As Prescribed By The Manufacturer.
7 Providing & laying controlled cement concrete M 250 including finishing smooth with curing 3.90 CMT 8932.05 Rs. Eight thousand nine hundred thirty two
complete including cost of plywood formworks only for fair finish and steel propping only so as to and paise five only
give fair finish but excluding the cost of reinforcement in COLUMN UPTO PLINTH.For any
cross sectional area of column.Rates Are Inclusive Of Providing & Mixing Plastisizer Of
Approved Make & In Proportion As per mix design
8 Providing & laying controlled cement concrete M 250 including finishing smooth with curing 45.50 CMT 9881.71 Rs. Nine thousand eight hundred eighty one
complete including cost of formworks only for fair finish and steel propping only so as to give fair and paise seventy one only
finish but excluding the cost of reinforcement in RCC WALL for ground floor.Rates Are Inclusive
Of Providing & Mixing Plastisizer Of Approved Make & In Proportion As per mix design- Up to
9 Providing & laying controlled cement concrete M 250 including finishing smooth with curing 9.50 CMT 9922.42 Rs. Nine thousand nine hundred twenty two
complete including cost of formworks only for fair finish and steel propping only so as to give fair and paise fourty two only
finish but excluding the cost of reinforcement in RCC WALL for First floor.Rates Are Inclusive
Of Providing & Mixing Plastisizer Of Approved Make & In Proportion As per mix design :First
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
10 Providing & laying controlled cement concrete M 250 including finishing smooth with curing 10.00 CMT 9963.13 Rs.nine thousand nine hundred sixty three
complete including cost of formworks only for fair finish and steel propping only so as to give fair and paise thirteen Only
finish but excluding the cost of reinforcement IN RCC WALL for Second floor.Rates Are
Inclusive Of Providing & Mixing Plastisizer Of Approved Make & In Proportion As per mix
design:Second floor
11 Providing & laying controlled cement concrete M 250 including finishing smooth with curing 9.00 CMT 10003.84 Rs. Ten thousand three and paise eighty
complete including cost of formworks only for fair finish and steel propping only so as to give fair four Only
finish but excluding the cost of reinforcement in RCC WALL for Third floor.Rates Are Inclusive
Of Providing & Mixing Plastisizer Of Approved Make & In Proportion As per mix design : Third
12 Providing & laying controlled cement concrete M 250 including finishing smooth with curing 1.00 CMT 7257.99 Rs. Seven thousand two hundred fifty seven
complete including cost of plywood formworks only for fair finish and steel propping only so as to and paise ninety nine Only
give fair finish but excluding the cost of reinforcement in PLINTH BEAMS for any cross
sectional area of beam.Rates Are Inclusive Of Providing & Mixing Plastisizer Of Approved Make
& In Proportion As per mix design
13 Providing & laying controlled cement concrete M-250 & including finshing smooth with curing 1.00 CMT 7735.87 Rs. Seve thousand seven hundred thirty five
etc. complete including the cost of form work but excluding the cost of reinforcement for RCC and paise eighty seven Only
work for SLAB for thickness 13 to 15 cms... etc. The rates are also inclusive of providing and
mixing plastisizer of approved make in proportion priscribed by manufacturer. Ground floor
14 Providing & laying controlled cement concrete M-250 & including finshing smooth with curing 1.00 CMT 7776.58 Rs.seven thousand seven hundred seventy
etc. complete including the cost of form work but excluding the cost of reinforcement for RCC six and paise fifty eight Only
work for SLAB for thickness 13 to 15 cms... etc. The rates are also inclusive of providing and
mixing plastisizer of approved make in proportion priscribed by manufacturer. First floor
15 Providing & laying controlled cement concrete M-250 & including finshing smooth with curing 1.00 CMT 7817.29 Rs. Seven thousand eight hundred
etc. complete including the cost of form work but excluding the cost of reinforcement for RCC seventeen and paise twenty nine only
work for SLAB for thickness 13 to 15 cms... etc. The rates are also inclusive of providing and
mixing plastisizer of approved make in proportion priscribed by manufacturer. Second floor
16 Providing & laying controlled cement concrete M-250 & including finshing smooth with curing 1.80 CMT 7858.00 Rs.seven thousand eight hundred fifty eight
etc. complete including the cost of form work but excluding the cost of reinforcement for RCC only
work for SLAB for thickness 13 to 15 cms... etc. The rates are also inclusive of providing and
mixing plastisizer of approved make in proportion priscribed by manufacturer. Third floor
17 Providing and Laying controlled cement concrete M-250 and including finishing smooth with 0.50 CMT 9045.03 Rs. Nine thousand fourty five and paise
curing etc.complete. Including the cost of formwork but excluding the cost of reinforcement for three only
R.C.C work in beam having any cross section area of BEAM.Rate are also inclusive of
Providing and mixing Plasticizer of approved make in proportion prescribed by Manufacturer.
Ground Floor Formwork Shall be used with plywood shuttering & Steel props.
18 Providing and Laying controlled cement concrete M-250 and including finishing smooth with 0.50 CMT 9085.74 Rs.nine thousand eighty five and paise
curing etc.complete. Including the cost of formwork but excluding the cost of reinforcement for seventy four only
R.C.C work in beam having any cross section area of BEAM.Rate are also inclusive of
Providing and mixing Plasticizer of approved make in proportion prescribed by Manufacturer.
First Floor Ground Floor Formwork Shall be used with plywood shuttering & Steel props.
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
19 Providing and Laying controlled cement concrete M-250 and including finishing smooth with 0.50 CMT 9126.45 Rs.nine thousand one hundred twenty six
curing etc.complete. Including the cost of formwork but excluding the cost of reinforcement for and paise fourty five only
R.C.C work in beam having any cross section area of BEAM.Rate are also inclusive of
Providing and mixing Plasticizer of approved make in proportion prescribed by Manufacturer.
Second Floor Ground Floor Formwork Shall be used with plywood shuttering & Steel
20 Providing and Laying controlled cement concrete M-250 and including finishing smooth with 0.50 CMT 9167.16 Rs.nine thousand one hundred sixty seven
curing etc.complete. Including the cost of formwork but excluding the cost of reinforcement for and paise sixteen only
R.C.C work in beam having any cross section area of BEAM.Rate are also inclusive of
Providing and mixing Plasticizer of approved make in proportion prescribed by Manufacturer.
Third Floor Ground Floor Formwork Shall be used with plywood shuttering & Steel
21 Providing T.M.T. Fe-500 Steel reinforcement for RCC work including cutting, bending, binding 27100.00 kg 78.34 Rs. Seventy eight and paise thirty four only
and placing in position etc. complete for all floors.Brand as approved by GSPHC.
22 BRICK WORK using common burnt clay building bricks having crushing strength not less than 2.00 CMT 4458.23 Rs. Four thousand four hundred fifty eight
35 Kg./Sq cm. In super structure above plinth level. Conventional bricks shall be used only in and paise twenty three only
cement moratar 1 : 6 ( 1 cement : 6 coarse sand) for GROUND FLOOR
23 BRICK WORK using common burnt clay building bricks having crushing strength not less than 0.50 CMT 4499.93 Rs. Four thousand four hundred ninety nine
35 Kg./Sq cm. In super structure above plinth level. Conventional bricks shall be used only in and paise ninety three only
cement moratar 1 : 6 ( 1 cement : 6 coarse sand) for FIRST FLOOR
24 BRICK WORK using common burnt clay building bricks having crushing strength not less than 0.50 CMT 4541.63 Rs. Four thousand five hundred fourty one
35 Kg./Sq cm. In super structure above plinth level. Conventional bricks shall be used only in and paise sixty three only
cement moratar 1 : 6 ( 1 cement : 6 coarse sand) for SECOND FLOOR
25 Brick work using common burnt clay building bricks having crushing strength not less than 35 1.00 CMT 4583.33 Rs. Four thousand five hundred eighty three
Kg/Sq.cm.in superstructure above plinth up to floor two level in conventional bricks in cement and paise thirty three only
mortar 1:6(1-cement;6-fine sand) for Third Floor.
26 Providing 10 mm thick cement PLASTER in single coat on ceilings for interior plastering and 3.50 SMT 209.88 Rs. Two hundred nine and paise eighty eight
finished even & smooth in C.M. 1: 3 ( 1 cement : 3 sand ) including finishing with a floating coat only
of neat cement slurry at GROUND FLOOR.
27 Providing 10 mm thick cement PLASTER in single coat on ceilings for interior plastering and 3.50 SMT 236.99 Rs. Two hundred thirty six and paise ninty
finished even & smooth in C.M. 1: 3 ( 1 cement : 3 sand ) including finishing with a floating coat nine only
of neat cement slurry at FIRST FLOOR.
28 Providing 10 mm thick cement PLASTER in single coat on ceilings for interior plastering and 3.50 SMT 264.10 Rs. Two hundred sixty four and paise ten
finished even & smooth in C.M. 1: 3 ( 1 cement : 3 sand ) including finishing with a floating coat only
of neat cement slurry at SECOND FLOOR.
29 Providing 10 mm thick cement PLASTER in single coat on ceilings for interior plastering and 6.60 SMT 291.21 Rs. Two hundred ninety one and paise
finished even & smooth in C.M. 1: 3 ( 1 cement : 3 sand ) including finishing with a floating coat twenty one only
of neat cement slurry at THIRD FLOOR.
30 Provinding 15 mm thick cement PLASTER in single coat on brick or concrete wall for interior 190.50 SMT 213.51 Rs. Two hundred thirteen and paise fifty one
plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing only
with floating coat of neat cement slurry at GROUND FLOOR.
31 Provinding 15 mm thick cement PLASTER in single coat on brick or concrete wall for interior 13.50 SMT 242.77 Rs. Two hundred fourty two and paise
plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing seventy seven only
with floating coat of neat cement slurry at FIRST FLOOR.
32 Provinding 15 mm thick cement PLASTER in single coat on brick or concrete wall for interior 12.50 SMT 272.03 Rs. Two hundred seventy two and paise
plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 sand ) including finishing three only
with floating coat of neat cement slurry at SECOND FLOOR.
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
33 Provinding 20 mm thick SAND FACED cement PLASTER on walls above ground level 163.00 SMT 312.56 Rs. Three hundred twelve and paise fifty six
consisting 12 mm thick backing coat of C.M. 1: 3 ( 1 cement : 3 sand ) and 8mm thock finishing only
coat of C.M. 1:1 ( 1 cement : 1 sand ) etc. Complete for any height.
34 Providing CEMENT VATA ( 10cm x 10cm )size quarter round in cement mortar 1 : 1 including 10.50 rmt 24.04 Rs. Twenty four and paise four only
neat cement finishing, watering etc. Complete.
35 Providing & Laying integrated cement based proprietary water proofing treatment of required 9.00 SMT 912.58 Rs. Nine hundred twelve and paise fifty eight
thickness over the roof including 10mm thick cement mortar 1:3 and CHINA MOSAIC fitting and only
finally finishing the surface with white cement slurry and sloping out terrace slabs with
Following specification laid to required slope not flatter than 1:80 ( the thickness of water
proofing treatment near rainwater outlet or the lowest point of the finished slope shell not to be
less than 45 mm. Including treating the vertical surface of the parapet wall up to 20 cm. height
above finished level of terracing including finishing top with joint less water proofing plaster
curing testing etc, completed. Rate is Including 10 years performance of guarantee bond to be
given on stamp paper ( no extra shall be paid for increase in thickness for proper slope ).
(A) Applying & grounting a slurry coat of neat cement using 2.75 kg/smt. of cement admixed
with proprietary water proofing compound confirming to IS 2645 and 10mm. Thick water
proofing cement plaster in cement mortar in 1:3.over the RCC slab including cleaning the
surface before treatments.
(B) Laying cement concrete using broken brick bat using 25 mm to 40 mm size with 50% of
cement mortar 1:4 ( 1 cement : 4 corse sand )over 10mm. thick water proofing cement plaster
in cement mortar in 1:3 admixed with proprietary water proofing compound conforming to IS
2645 required slope and treating similarly the adjoining walls up to 200 mm height including
rounding of junction of walls.
(C) After two days of proper curing applying a second coat of cement slurry .
(D) Finishing the surface with china mosaic peices laid on 10 mm thick joint less cement mortar
of mix 1:3 ( 1 cement : 3 sand) admixed with proprietary water proofing compound confirming to
IS 2645 and finally finishing the surface with trowel with neat cement slurry .
(E) The whole terrace so finished shall be flooded with water for a minimum period of two weeks
for curing for final test. All above operation to be done in order and as directed and specified by
the engineer in charge.
36 Finishing Ceilling/Slop Surface with Plastic Emulsion Paint on Ceilling/Slop Surface (two 17.50 SMT 193.29 Rs. One hundred ninety three and paise
coats) to give an required shap even shade after throughly brushing the surface to remove all twenty nine Only
dirt and remains of loose poweder material etc. complete. Rate are inclusive of applying two
coat of lapy (Putty) and one coat of primer on new Ceilling/Slop Surface to give and even shade
including thoroughly brushing the surface free from mortar dropping and other foreign matter
and sand papered smooth. Fine Putty Shall be Bison Wall Putty of Berger Paint India Ltd or
Trucare Wall Putty of Asian Paint or Dulux Polly Putty of Dulux Paint Only & Primer shall be BP
White Primer of Berger Paint India Ltd or Asian Paint Trucare Interior Primer of Asian Paint or
Interior Sealer A 500 of Dulux Paint only and Plastic Emulsion paint Shall be Rangoli Total Care
of Berger Paint India Ltd or Apcolite Premium Emulsion of Asian Paint or Dulux Interior A 900 of
Dulux Paint only.
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
37 :- Finishing Wall with Plastic Emulsion Paint on Wall Surface (two coats) to give an required 180.00 SMT 180.25 Rs. One hundred eighty and paise twenty
shap even shade after throughly brushing the surface to remove all dirt and remains of loose five Only
poweder material etc. complete. Rate are inclusive of applying two coat of lapy (Putty) and one
coat of primer on new wall surface to give and even shade including thoroughly brushing the
surface free from mortar dropping and other foreign matter and sand papered smooth. Fine
Putty Shall be Bison Wall Putty of Berger Paint India Ltd or Trucare Wall Putty of Asian Paint
or Dulux Polly Putty of Dulux Paint Only & Primer shall be BP White Primer of Berger Paint
India Ltd or Asian Paint Trucare Interior Primer of Asian Paint or Interior Sealer A 500 of Dulux
Paint only and Plastic Emulsion paint Shall be Rangoli Total Care of Berger Paint India Ltd or
Apcolite Premium Emulsion of Asian Paint or Dulux Interior A 900 of Dulux Paint only.
38 Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) over 155.00 SMT 153.35 Rs. One hundred fifty three and paise thirty
and above applying One Coat Of Primer to give an required shape even shade after thoroughly five Only
brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete.
Primer Shall be Weather Coat Exterior Primer of Berger Paint India Ltd or Asian Paint Trucare
Exterior Primer of Asian Paint Or Exterior Sealer E 900 of Dulux Paint only and exterior
emulsion paint Shall be Weather Coat Smooth of Berger Paint India Ltd or Apex Weather Proof
Emulsion of Asian Paint or Dulux Weather Shield Projecs of Dulux Paint Only
39 Finishing wall with white wash on wall surface (three coats) to give an even shade after 167.00 SMT 18.85 Rs. Eighteen and paise eighty five Only
thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc
40 Providing and Laying 25mm thick Mirror Polished (Dimond Cut) Kota Stone Slab Flooring over 20mm thick base of cement 45.50 SMT 1108.30 Rs. One thousand one hundred eight and
mortar 1 : 6 (1-Cement : 6-Coarse Sand) laid over and jointed with grey cement slurry including Rubbing and Polishing etc.
Complete as Directed By Engineer In Charge for all Floors.
paise thirty only
41 Providing and Fixing Granite of Telephonic Black Colour 18mm thick for jambs and sills of doors 27.10 SMT 2428.00 Rs. Two thousand four hundred twenty eight
& windows using neat cement slurry laid over 20 mm average base of cement mortar 1:1 (1 only
cement:1 Coarse Sand) and jointed with grey cement slurry including racking (Tancha Work)
rubbing and polishing, scaffoldings, tools and tackles, scaffolding etc. complete. (with base of
neat cement) as per direction of Engineer in charge including rounding the exposed edges as
directed etc. Complete for ALL FLOORS.
42 Providing , Fabricating and fixing M.S. GRILL/GATE of approved pattern fabricated from M.S. 1510.00 KG 75.11 Rs. Seventy five and paise elevan Only
flat,square bars, round bars,c-channel, box pipe as per detail Drawings. Rate is inclusive of
welding with grinding smooth surface, two coats of Oil paint and one coat of yellow Zinc primer
coat. Oil paint shall be as per approved brand list of GSPHCL The structural steel shall be used
43 FIX GLASS WINDOW Providing and fixing standard extruded of alluminium section of size 26.00 SMT 1509.90 Rs. One thousand five hundred nine and
95.00 * 24.00 * 1.95 mm ( of Jindal section no:4605, @ Wt 1.094 Kg/RMT with colour anodized paise ninety Only
alluminium frame with 5 mm thick transparent bronze colour tinted float glass as details etc
complete for fix window
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
44 Providing and fixing Alluminium Section Window having extruded Aluminum Colour anodized 10.00 SMT 1902.50 Rs. One thousand nine hundred two and
section frame main outer size 95mm x 24mm x 1.17mm (of Jindal Section no:2459 @ wt.of paise fifty Only
0.738 Kg/mt), horizontal Three track member size 92mm x 31.75mm x 1.30mm (of Jindal
Section no:8688,@ Wt.1.07 Kg/mt), vertical member of size 92mm x 31.75mm x 1.50mm (of
Jindal Section no:8933,@ Wt. 1.06 Kg/mt) with sliding shutters of horizontal member size
40mm x 18mm x 1.29mm (of Jindal Section no:8947@ wt.of 0.456 Kg/mt), vertical member of
size 40mm x 18mm x 1.29 mm (of Jindal Section no:8949 @ wt.of 0.456Kg/mt) with 5 mm thick
transparent bronze colour tinted float glass with powder coated aluminum fittings and fixtures
and transparent silicon sealant glass fixing to frame as per details including One Mosquitoe Jalli
Shutter With Both Side Locking Arrangment.
45 Rebaring of 12 mm dia steel bars up to depth suggested by structural consultant or min. 150 40.00 NO 120.00 Rs. One hundred twenty only
mm, with HILTI chemical grouting at all floors for all size bars as per the instruction of EIC.
46 Rebaring of 16 mm dia steel bars up to depth suggested by structural consultant or min. 150 121.00 NO 161.00 Rs. One hundred sixty one Only
mm, with HILTI chemical grouting at all floors for all size bars as per the instruction of EIC.
47 Dismentling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats 6.00 NO 195.14 Rs. One hundred ninety five and paise
architraves, holdfasts and other attachment etc. complete and stacking them within all lead and fourteen Only
lift.(i) Not exceeding 3 Sq.M. in area.
48 Demolition including stacking of serviceable materilas and disposal of unserviceable materials 15.90 CMT 1099.75 Rs. One thousand ninety nine and paise
with all lead and lift. (i) R.C.C. Work seventy five Only
49 Demolition of brick work & stone masonary incl. stacking of servicable material & disposal of 11.00 CMT 572.20 Rs. Five hundred seventy two and paise
unservicable material (iii)In cement mortar with all lead and lift. twenty only
50 Steel Work welded in built up sections framed work including cutting, housting,fixing in position 337.50 KL 8750.00 Rs. Eight thousand seven hundred fifty Only
and applying priming coat of redlead paint [ A ] In beam and joints channels angles tees flats
with connecting plate or angle cleates as in main and crossed beam hip and jacke after, purlins
connected to common rafter and the like.
51 Applying priming coat over new steel and other metal surface after over and including preparing 765.00 SMT 127.35 Rs. One hundred twenty seven and paise
the surface by throughly cleaning oil, grease dirt and other foreign matter and scoured with thirty five only
brushes fine steel wool, scrapers and sand paper with ready mixed priming paint brushing red
lead AND Painting two coatsover it with enamel paint brushing, interior to give an even shade
including cleaning the surface of all dift, dust and other foreign matter.
52 Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and 87.00 SMT 49.61 Rs. Fourty nine and paise sixty one Only
disposal of serviceable materials with all lead and lift
53 Demolition incl. stacking of serviceable materials & disposal of unserviceable material with all 9.00 CMT 633.39 Rs. Six hundred thirty three and paise thirty
lead & lift (i)Unreinforcement work nine Only
54 Design, Supply and fixing of FR Grade alluminium composit panels with necessary framing 678.00 SMT 5060.00 Rs. Five thousand sixty Only
material for covering of structural lift shaft with specializedmanpower for working at height on
open structure (G+3 FLOORS). ACP sheet thickness 3mm. with ms frames of 35 x 25 MS Pipe
with two coat primer as directed by Engineer - in - charge properly screwed over necessory
structural framing. ACP should be properly fixed and screwed with the frame and all joints to be
filled and finished with silicone in pattern suggested by the architect with tray system. Colours
also should matalic or any colour be selected as per architects instructions. rate includs acp, ms
frame, fixtures, fittings, scafolding, etc. complete and work to be done as per the instructions of
TOTAL CIVIL COST(A)
ELECTRICAL WORK
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
55 Designing, Supplying, Erecting, Testing and Commissioning of 1500 Kg Capacity Goods ( 3.00 Per Job 2275537.00 RS: Twenty Two lac Seventy Five
Ground+ 03 upper Floor) Machine Room Less ( MRL) lift ( in fabricated structure M.S. lift well Thousand Five Hundred Thirty Seven
developed by lift Agency) having following main features:[1] GEAR LESS LIFT DRIVE comprising only
of High Starting torque Lift duty 3 phase 440 V A. C. Permanent magnetic synchronous motor of
proper rating with high efficiency shall be used. [2] Micro processor based / PLC, ACVVF, vector
control drive with encoder feedback closed loop system shall be used for lift car and door
operation which shall be full collective selective operation hall call demand response,
UP/DOWN hall stops, Main, Up/ Down Contactor with overload and phase reversal relay and
safety controls. [3] Car with fabricated platform having 3mm or more thick MS heavy duty
plate with support at 200mm spacing with bracings of adequate size and to sustain the impact
load cabin + Goods with safety factor of fire for steel and side panels of Stainless steel of sheet
of grade 304 duty & 1.5mm thick sheet & Trolly Guard with suitable height at car. . Car
ceiling will be S.S. finishes with aesthetic appearance with LED ceiling lights. Car flooring shall
be 3.00 mm heavy duty MS Chequre Plate having adequate thickness & strength to
withstand load & impact of M.S. loading trolly and books Flooring , Car doors & Landing
Door shall be of stainless steel grade 304 & 1.5mm thick sheet , hairline finish with centre
opening / telescopic automatic doors. Guiding Sill made from MS Solid flat bar with groove &
ISMC 100X50mm for sill support at every landing . Car panel will also be S.S. 304 finished &
1.5mm thick sheet with emergency stop device, mechanical door safety device, facility of auto/
attended mode. All car panel buttons and all floor switches must be with brail language as per
lift act. Minimum Car Area Inside:- 1600mm WideX2350mm Deep(3.68 Sq. Meter) & Clear
Door Opening:-1400mm or as per site requirement Wide X2000mm Height
[4] All landing doors must be fire rated for 2 hours necessary test certificate shall be
fully automatic centre opening/ telescopic opening made of hairline finish steel grade of
304 & 1.5mm thick sheet with key holes and infrared curtains with Unlocking facility
from outside [5] Appropriate battery operated emergency light in the car along with
alarm switch shall be provided also ememergency light and fan should start
immediately without any time delay as soo as power fail.[6] Digital scrolling indicator
system for up down arrow along with floor position indicator shall be provided inside the
car and at all floors.[7] Full height infra red curtain with multiple cross / crossing light
beams shall be provided.
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
[8] Automatic Rescue Device (ARD)(seprate UPS) shall be provided accordingly of
Goods capacity with manual rescue operation(manual cranking facility. [9] Audio visual
indication in the lift car showing over loading shall be provided such that doors kept
open till excess load is removed.[10] Spring buffers/PU Buffers shall be provided..[11]
Car rotor motor Fan with automatic sleep timer shall be provided.[12] Voice
annunciate with suitable music shall be provided in lift car.[13] Self diagnostics system
for operational and safety parameters shall be provided in control panel .[14]
Mechanical over speed governor with governor calibration as per actual site perameter
and submission of calibration certificate submission door key holes in the floor doors,
fireman switch shall be provided. [15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit should be provided by the lift agency, along
with the other steel structure works, foundations for the machine etc…[16] In the hoist
way fascia plate shall be provided without any extra cost, where ever required as / if
directed by engineer in charge
.[17] Permanent wiring in lift machine room and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug points shall be provided by the agency.
Power supply of 3 phase 440 V shall be made available by department in lift machine
room .[18] Any civil/ electrical works for additional and alteration in lift shaft and
machine room related to erection of lift shall be made by lift agency without any extra
cost.[19] Agency Has To Provide All Working Drawing and Document and Liaison
Service For Obtainning All Necessary Permission From Lift Inspector and Other
Authorities. Agency Has To Provide All Working Drawing and Document and Liaison
Service For Obtainning All Necessary Permission From Lift Inspector and Other
Authorities, The legal and other charges to get erection permission and Final Licence
also will be borne by contractor [20] acrylic transparent licence/display A4 size holder in
[20a]As Per Statutory Requirement Of Govt Of Gujarat Lift and Escalator Act 2000,Lift
Agency has To Provide.1.Car Top Safety Barier 2.Push and Talk Communication
system 3.Fireman s Switch Operation at Ground Floor 4.carrying out third party lift
inspection during/after lift erection and provide report by third party authorized by
concern licensing authority 5.agency has to provide third party insurance upto
completion of free maintenance period and submit the document for the same. [21] Car
Panel Operating Buttons with floor position indicator/buttons must be of Auto Glow type
clearly visible when view from inside cabin. (22 ) Required Capacity of Three Phase
Voltage Stabilizer as per Lift OEM Requirement Having Input voltage Range 340 to
480 Volt AC and Output Voltage Range 415 Volt AC + 1% ( line Line ). Voltage
stabilizer must be installed at Machine Room/ Electrical room .
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
(23) Advanced Control system dual 32 bit embedded microprocessor with CANBUS
serial communication mode operation on site programming facility , anti nuisance, pre
opening, BMS/ RMS system supporting hardware and Software. False call Canceling/
Anti Nuisance, [24] Intercom Suitable For Hook Up To EPBAX (25) As per gujarat lift
and escalator act 2001 and central electricity authority regulations 2010, RCCB for lift
cabin and lift machine must be installed in control panel by lift manufacturer(26) In this
tender , Agency has to maintain all lift including Service and Spare Parts during Defect
Liability period as per item included in tender. one year free service and Maintenance
shall be provided by OEM. Details specification of lift as per Annexure A (a) For
Kg Goods MRL Type Ground + 3 upper Floor ) with Rated Speed of 1.0 m/sec
with micro processor /PLC control and ACVVVF.drive
Designing, Supplying, Erecting, Testing and Commissioning of 1500 Kg Capacity Goods ( 1.00 Per Job 2110275.00 RS: Twenty One lac Ten Thousand
Ground+ 02 upper Floor) Machine Room Less ( MRL) lift ( in RCC shaft) having following main Two Hundred Seventy Five only
features:[1] GEAR LESS LIFT DRIVE comprising of High Starting torque Lift duty 3 phase 440 V A.
C. Permanent magnetic synchronous motor of proper rating with high efficiency shall be used.
[2] Micro processor based / PLC, ACVVF, vector control drive with encoder feedback closed loop
system shall be used for lift car and door operation which shall be full collective selective
operation hall call demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with
overload and phase reversal relay and safety controls. [3] Car with fabricated platform
having 3mm or more thick MS heavy duty plate with support at 200mm spacing with bracings
of adequate size and to sustain the impact load cabin + Goods with safety factor of fire for steel
and side panels of Stainless steel of sheet of grade 304 duty & 1.5mm thick sheet & Trolly
Guard with suitable height at car. . Car ceiling will be S.S. finishes with aesthetic appearance
56 with LED ceiling lights. Car flooring shall be 3.00 mm heavy duty MS Chequre Plate having
adequate thickness & strength to withstand load & impact of M.S. loading trolly and books
Flooring , Car doors & Landing Door shall be of stainless steel grade 304 & 1.5mm thick
sheet , hairline finish with centre opening / telescopic automatic doors. Guiding Sill made from
MS Solid flat bar with groove & ISMC 100X50mm for sill support at every landing . Car
panel will also be S.S. 304 finished & 1.5mm thick sheet with emergency stop device,
mechanical door safety device, facility of auto/ attended mode. All car panel buttons and all
floor switches must be with brail language as per lift act. Minimum Car Area Inside:- 1600mm
WideX2350mm Deep(3.68 Sq. Meter) & Clear Door Opening:-1400mm or as per site
requirement Wide X2000mm Height
[4] All landing doors must be fire rated for 2 hours necessary test certificate shall be
fully automatic centre opening/ telescopic opening made of hairline finish steel grade of
304 & 1.5mm thick sheet with key holes and infrared curtains with Unlocking facility
from outside [5] Appropriate battery operated emergency light in the car along with
alarm switch shall be provided also memergency light and fan should start immediately
without any time delay as soo as power fail.[6] Digital scrolling indicator system for up
down arrow along with floor position indicator shall be provided inside the car and at all
floors.[7] Full height infra red curtain with multiple cross / crossing light beams shall be
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
[8] Automatic Rescue Device (ARD)(seprate UPS) shall be provided accordingly of
Goods capacity with manual rescue operation(manual cranking facility. [9] Audio visual
indication in the lift car showing over loading shall be provided such that doors kept
open till excess load is removed.[10] Spring buffers/PU Buffers shall be provided..[11]
Car rotor motor Fan with automatic sleep timer shall be provided.[12] Voice
annunciate with suitable music shall be provided in lift car.[13] Self diagnostics system
for operational and safety parameters shall be provided in control panel .[14]
Mechanical over speed governor with governor calibration as per actual site perameter
and submission of calibration certificate submission door key holes in the floor doors,
fireman switch shall be provided. [15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit should be provided by the lift agency, along
with the other steel structure works, foundations for the machine etc…[16] In the hoist
way fascia plate shall be provided without any extra cost, where ever required as / if
directed by engineer in charge
.[17] Permanent wiring in lift machine room and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug points shall be provided by the agency.
Power supply of 3 phase 440 V shall be made available by department in lift machine
room .[18] Any civil/ electrical works for additional and alteration in lift shaft and
machine room related to erection of lift shall be made by lift agency without any extra
cost [19] Agency Has To Provide All Working Drawing and Document and Liaison
Service For Obtainning All Necessary Permission From Lift Inspector and Other
Authorities. Agency Has To Provide All Working Drawing and Document and Liaison
Service For Obtainning All Necessary Permission From Lift Inspector and Other
Authorities, The legal and other charges to get erection permission and Final Licence
also will be borne by contractor [20] acrylic transparent licence/display A4 size holder in
[20a]As Per Statutory Requirement Of Govt Of Gujarat Lift and Escalator Act 2000,Lift
Agency has To Provide.1.Car Top Safety barier 2.Push and Talk Communication
system 3.Fireman s Switch Operation at Ground Floor 4.carrying out third party lift
inspection during/after lift erection and provide report by third party authorized by
concern licensing authority 5.agency has to provide third party insurance upto
completion of free maintenance period and submit the document for the same. [21] Car
Panel Operating Buttons with floor position indicator/buttons must be of Auto Glow type
clearly visible when view from inside cabin. (22 ) Required Capacity of Three Phase
Voltage Stabilizer as per Lift OEM Requirement Having Input voltage Range 340 to
480 Volt AC and Output Voltage Range 415 Volt AC + 1% ( line Line ). Voltage
stabilizer must be installed at Machine Room/ Electrical room .
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
(23) Advanced Control system dual 32 bit embedded microprocessor with CANBUS
serial communication mode operation on site programming facility , anti nuisance, pre
opening, BMS/ RMS system supporting hardware and Software. False call Canceling/
Anti Nuisance, [24] Intercom Suitable For Hook Up To EPBAX (25) As per gujarat lift
and escalator act 2001 and central electricity authority regulations 2010, RCCB for lift
cabin and lift machine must be installed in control panel by lift manufacturer(26) In this
tender , Agency has to maintain all lift including Service and Spare Parts during Defect
Liability period as per item included in tender. one year free service and Maintenance
shall be provided by OEM. Details specification of lift as per Annexure A (a) For
Kg Goods MRL Type Ground + 2 upper Floor ) with Rated Speed of 1.0 m/sec
with micro processor /PLC control and ACVVVF.drive
57 Executing coprehensive (All in All) service( Per Month) and maintenance(Including 3.00 Per Job 250309.00 RS: Two lac Fifty Thousand Three
replacement of battery For ARD) with spare parts as per terms and condition of tender Hundred Nine only
lift manufacture for defect liability period.For that main agancy has to give All in All
comprehensive maintenance contract to lift manufacturer and copy of this contract will
be submitted before final bill .Agency has to quote rate accordingly.Agency has to also
provide the fitness certificate from lift manufacturer and submit to GSPHCL.Agency has
to Compulsory submit FDR of approved bank as per clause 2.0 of section -3, of
Rs 7,50,927.00 + GST or quoted amount whichever is higher to GSPHCL.for minimum
maturity period of Five years in favour of GSPHCL. Which will be releard after successful
completion of AMC and at the and of defect liability period. in any case without submitting
FDR final bill submission will not be done.lift OME has to mantain written record of sevice
and maintenance during defect libility daily period and one copy of necessary service report
duly sign by pathypustakmandal dept.and submited redulary to GSPHCL.and No Defect
Certificate from pathypustakmandal department at the time of releasing Security Deposite will
be submitted to EE (Ele.), GSPHCL. Without above Service reports security Deposit of whole
project will not be released. (OEM will have to submit stability and performance certificate
regarding Lift at the time of final SD release). Lift agency has to do maintance as per term and
Condition altarenet in tender for delay in rectifing the fault,penalty will be deduced from agency
S.D. For 1500 Kg Capacity Goods ( Ground+ 03 upper Floor)
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
58 Executing coprehensive (All in All) service( Per Month) and maintenance(Including 1.00 Per Job 232130.00 RS: Two lac Thirty Two Thousand One
replacement of battery For ARD) with spare parts as per terms and condition of tender Hundred Thirty only
lift manufacture for defect liability period.For that main agancy has to give All in All
comprehensive maintenance contract to lift manufacturer and copy of this contract will
be submitted before final bill .Agency has to quote rate accordingly.Agency has to also
provide the fitness certificate from lift manufacturer and submit to GSPHCL.Agency has
to Compulsory submit FDR of approved bank as per clause 2.0 of section -3, of
Rs 2,32,130 + GST or quoted amount whichever is higher to GSPHCL.for minimum maturity
period of Five years in favour of GSPHCL. Which will be releard after successful completion
of AMC and at the and of defect liability period. in any case without submitting FDR final bill
submission will not be done.lift OME has to mantain written record of sevice and
maintenance during defect libility daily period and one copy of necessary service report duly
sign by pathypustakmandal dept.and submited redulary to GSPHCL.and No Defect Certificate
from pathypustakmandal department at the time of releasing Security Deposite will be
submitted to EE (Ele.), GSPHCL. Without above Service reports security Deposit of whole
project will not be released. (OEM will have to submit stability and performance certificate
regarding Lift at the time of final SD release). Lift agency has to do maintance as per term and
Condition altarenet in tender for delay in rectifing the fault,penalty will be deduced from agency
S.D. For 1500 Kg Capacity Goods ( Ground+ 02 upper Floor)
59 Providing and erecting Medium Class FIA approved and ISI mark white colour (embossed) 665.00 Mtr. 33.00 RS: Thirty Three only
RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & clamps on / in wall / ceiling along with continuous fish wire
to draw mains with necessary fittings and junction boxes for following dia. (a) 25 mm. dia.
60 Providing & Erecting 2.0 mtr long Earthing system by making minimum bore of 225 mm dia in 2.00 Each 7025.00 RS: Seven Thousand Twenty Five
soft soil. Suitable for doing pipe-in-pipe technology earthing.Earthing electric rod must be made only
from Corrosion free Hot dip galvanizing pipes having following specification.
(A) Earthing Electrode: outerpipe:- 88 mm minimum O.D., ISI 'B ' Class ISI mark of Reputed
Brand, Inner pipe:- 42 mm minimum O.D., Pipe B Class ISI mark reputed Brand Terminal Size:
70mm X 100mm length, Terminal Should be made from inner pipe for that pipe must be
pressed and gave rectangular shape so its work as a terminal.The hot deep galvanising must
be done after above process.Galvanised thickness must be minimum 75 micron any where. SS
Nut bolt:- 2 no.with washer suitable for 14mm dia. hole must be provided at terminal. total
minimum Weight(approx.) of earth electrodewith inside conductive material minimum should be
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm/meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%
(C) Back fill Compound:- Earthing compound should be capable to retain moisture for long time
Back Filling Compound weight is 25 Kg.
(D) Chamber and cover:- Earthing chamber should be size of 400 mm X 400 mm X 400 mm
depth and Cover should be heavy duty cast iron with required size of 300 mm X 300 mm X
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
Necessary test report must be submitted.
1. Short circuit test by ERDA/ CPRI for 25KA
2. Resistivity test of conducting material from NABL accredited lab.
3. Hot dip galvanised / zinc coating micro test from reputed laboratory.
4. General test report from OEM regarding specification of earthing.
[Make and model approved by EIC Strictly subject to item specification only] [OEM has to
submit all detail & sample for approved before supplying]
[Water must be poured in bore before starting earthing. Earthing value must be measured with
earth tester. Agency has to bring the earth resistance to at least 02 ohms & voltage between
neutral & Earthing upto 02 volt. Agency has to maintain earthing & its value for one year.
Earthing must be done in the presence of A.E. (GSPHCL)]
61 Providing & Erecting Mains with ISI marked, 1.1 KV grade electrolyte multi stranded, annealed 730.00 Mtr. 141.00 RS: One Hundred Forty One
copper conductor with heat resistant PVC insulated conforms to IS:694, IEC - 227 erected in only
existing pipe of following size (Specifically for control panel, relays, power switchgears, motor
starters & control wiring) with required size of copper lugs, nuts and bolts if required. (a) one
wire 16.00 sq. mm
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking 1.00 Each 6112.00 RS: Six Thousand One Hundred
capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed Twelve only
thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU
63 Providing and erecting 415 Volt MCB four pole motor & inductive load(c Curve) having 10 KA 5.00 Each 730.00 RS: Seven Hundred Thirty only
Breaking capacity and confirms to IS : 8828 in existing metal box having following capacity. (a)
64 Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA 4.00 Each 709.00 RS: Seven Hundred Nine only
breaking capacity & confirms to IS :8828 in existing box having following capacity (a)63 Amp.
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) 6.00 Each 297.00 RS: Two Hundred Ninty Seven
having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity only
(A) 6 to 32 Amp DP
Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity 4.00 Each 3010.00 RS: Three Thousand Ten only
of 300 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on 3 phase
and neutral 415V,50Hz. having characteristic of quick action & tripping with all advance feature
66 & do not incorporate any electronic component for following Max. rating erected as directed. (i)
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity 4.00 Each 1950.00 RS: One Thousand Nine Hundred
of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single Fifty only
phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do
67 not incorporate any electronic component. for following Max. rating erected as directed (i)
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
Supply & Fixing of company fabricated Sheets steel powder coated enclosure Size 4''X6'' for 7.00 Each 272.00 RS: Two Hundred Seventy Two
incorporating Two nos. MCB.(MCBDB must be erected in line level & level with spirit level and only
finish the external edge with box cutting plaster)( Same color MCB(SP/DP) should be used as
same as MCBDB)( Incl. necessary numbiring /marking on box done with RED colour radium
68 sticker as per site requirement & instruction given by EIC on site. Font/ Number size given by
EIC on site as per requirement)(The enclosure should be used of same company of MCB/
ELCB to be used)
Supply & Fixing of company fabricated Sheets steel powder coated enclosure minimum Size 7.00 Each 442.00 RS: Four Hundred Forty Two
8''X6' for incorporating Four nos. MCB.(The enclosure should be used of same company of only
MCB/ ELCB to be used) (MCBDB must be erected in line level & level with spirit level and finish
the external edge with box cutting plaster)( Same color MCB(SP/DP) should be used as same
as MCBDB)( Incl. necessary numbiring /marking on box done with RED colour radium sticker as
per site requirement & instruction given by EIC on site. Font/ Number size given by EIC on site
as per requirement)
Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - 1.00 Each 13688.00 RS: Thirteen Thousand Six Hundred
flush / surface mounted double door (IP54) fitted with insulated copper busbar, isolated neutral Eighty Eight only
link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986,IP-54 suitable for 63/100
AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs
should be used of same company of MCB to be used) (a)8 way outgoing
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor 400.00 Mtr. 213.00 RS: Two Hundred Thirteen only
for 1.1 KV. to be laid on wall with necessary 1.0mmm cable clamps or in existing trench / pipe
71 of following size of cables (A) 3 core 2.5 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor 400.00 Mtr. 505.00 RS: Five Hundred Five only
for 1.1 KV. to be laid on wall with necessary 1.0mmm cable clamps or in existing trench / pipe
of following size of cables (A) 4 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium 20.00 Mtr. 189.00 RS: One Hundred Eighty Nine
conductor for 1.1 KV. to be laid on wall with necessary 1.0mmm cable clamps or in existing only
trench / pipe of following size of cables (A) 4 core 25 Sq. mm
Providing & fixing double compressed heavy duty flange type brass cable gland with rubber 23.00 Each 43.00 RS: Forty Three only
ring for P V C insulated armoured cable complete with outgoing tails, insulating tape etc. For
following size cables.(A) 2 to 4 core 2.5 / 4 Sq. mm (Sigma, MCI, Comet Make Only)
For 2 to 4 core x 6.0 Sq. mm (Sigma, MCI, Comet Make Only) 13.00 Each 48.00 RS: Forty Eight only
For 2 to 4 core x 25.0 Sq. mm (Sigma, MCI, Comet Make Only) 4.00 Each 61.00 RS: Sixty One only
ITEM NO Description QUANTITY Unit RATE IN RATE IN WORD Amount
Solderless crimping type Copper lugs conforming to IS suitable for cable of following size 144.00 Each 8.00 RS: Eight only
evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium
75 plated nut bolts in an approved manner. For 2.5/6 Sq.mm Cable ( Make:- Dowells, Comet,
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size 16.00 Each 15.00 RS: Fifteen only
evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium
76 plated nut bolts in an approved manner. For 25 Sq.mm Cable( Make:- Dowells, Comet,
Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The 140.00 Mtr. 420.00 RS: Four Hundred Twenty only
cable tray should be single or double bended as per required and as per IS 2062/1079 and shall
be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with
77 coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with
necessary support( included) as per Specification and as per instruction of engineer in
charge..(a) 150 X 50 X 1.6 mm Thick( Make:- Indiana , KEW, Metalem, LABH (Dudhat), )
TOTAL ELECTRICAL COST(B)
TOTAL COST(A+B)
Signature of Contractor DY.Executive Engineer Executive Engineer
Gandhinagar Gandhinagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.Cover page.pdf
2.0 SDB 1 to 4 book Pathypustak.pdf
3. SBD book Section -6 Form Bid.pdf
4. SBD Section-7 Bill of Quantities.pdf
5. SBD Book Section-8 Security and Other forms.pdf
6. SBD Book Section-9 Drawings..pdf
7. Attached Specification.pdf
8. Standard Specification.pdf
9.Schedule-B Lift Pathypustak Manadal.pdf
10. All Conditions.pdf
11.List of matrials.pdf
12. Cement Statement.pdf
13.Approved Bank Details upto March -20260.pdf
14.Genral Techinal Specification B S BOOK_ 24-3-23.pdf
15.Civil Mou Lift electrical condation Specification and make list.pdf
16.ELE3 specifications Booklet.pdf
17.Affidavit.pdf
GODOWN-12-FF.pdf
GODOWN-12-GF.pdf
GODOWN-12-LIFT SEC..pdf
GODOWN-12-SF.pdf
NEW GODOWN SECTION.pdf
new lift in new godown framing-signed.pdf
ST_01_FOUNDATION LAYOUT AND DETAILS FOR NEW LIFT-signed.pdf
ST_02_TYPICAL LINTEL SLAB BEAM LAYOUT AND DETAILS FOR NEW LIFT.pdf
ST-01_(01 OF 02)_FOUNDATION LAYOUT FOR NEW LIFT-signed.pdf
ST-01_(02 OF 02)_FOUNDATION DETAIL FOR NEW LIFT-signed.pdf
16.01.2026 N.I.T. ele 2025-26 no-2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .