Loading…
Loading…
Tender Value
₹96,616.60
Closing Date
18 May 2026, 5:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Deputy Executive Engineer Capital Project Sub Division No.10,Gandhinagar
2215 Water supply and sanitation. - (101) Gandhinagar Water supply Scheme Providing and erecting 10 H.P. panel and laying cable for Raj Bhavan and Pethapur Nursery in G.T.S.
303201
Notice No.2 of 2026-2027 Sub Division No.10.
Open
Civil - All
Gandhinagar
6 documents required · 6 mandatory
₹300
Deputy Executive Engineer Capital Project Sub Division No.10,Gandhinagar
8 May 2026
8 May 2026
8 May 2026
18 May 2026
8 May 2026
Name of Work :-2215 Water supply and sanitation. - (101) Gandhinagar Water supply Scheme Providing and
erecting 10 H.P. panel and laying cable for Raj Bhavan and Pethapur Nursery in G.T.S.
BILL OF QUAINTITIES
MEMORANDUM SHOWING THE ITEM OF WORKS TO BE CARRIED OUT
Item Description of Item Quantity Unit Rate In figures Amount
Lifting of submersible motor pump set
complete with required No .& size of casing
pipes by means of proper chain pulley block
and pipe. wrenches. Job includes stacking of
pipes chronologically after due checking of
threads. © Above 120 mtr.
Providing and erecting ISI marked PVC insulated
PVC Sheathed Flat flexible Submersible
copper cable approved make of following Size.
(G) 3 Core x 25 Sq. mm
Item Description of Item Quantity Unit Rate In figures Amount
Providing and erecting ISI marked PVC insulated
PVC Sheathed Flat flexible Submersible
copper cable approved make of following Size.
(E) 3 Core x 10 Sq. mm.
Providing Water proof straight Joint in PVC
insulated flat flexible copper cable by using
insulating material, water proofing material, &
making the joint complete. (B) 16 to 35 Sq. mm
Providing & laying approved make Double
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable (A) 50 mm outer dia
Item Description of Item Quantity Unit Rate In figures Amount
Making trench in soft soil of suitable width of
cm deep for laying cable or locating the fault all
over the run and back filling the same and
making the surface as normal ground.
Item Description of Item Quantity Unit Rate In figures Amount
Supplying & erecting approved make 3 phase
motor control cubical panel ( Star - Delta)
made from16 G. CRCA sheet duly painted with
epoxy powder painted inside and outside with
hinged doors and locking arrangement,
consisting of suitable size of ON- OFF isolator
(AC - 3/23 duty) main fuses, single phasing
preventer cum water level. Guard (Complete
unit), Toggle switch to by pass Single phase
preventer cum WLG, indicating lamps for R- Y- B
phases, over load relay, Automatic water level
controller, Ammeter & Voltmeter each with two
way selector switch incoming wires duly socket
Crimped, Panel to be erected on angle iron
frame grouted on wall as directed. Star Delta &
main contactor, overload relay, thermal /
Electronic Star delta cutoff timer, start - stop
push buttons. The isolator overload relay &
contactors of L& T, Siemens or Cuttler Hamer
make only. Panel to be erected on angle iron
frame ground on wall. (B) S/D up to 10 H.P.
Rupees Ninety six thousand six hundred sixteen and paise sixty only.
Deputy Executive Engineer,
Capital Project Sub Division No.10,
Item Description of Item Quantity Unit Rate In figures Amount
I/We am/are willing to carry out the above work @ ____________ % below/above percent (should be written in figures
and words) of the estimated rates mentioned above Amount of my/our tender works out as under.
Estimated cost put to tender Rs. 96,616=60 Estimated cost put to tender Rs. 96,616=60
Deduct ___________% below Add__________% above
In words In Words
Note 1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge
for which no extra payment shall be made.
Note 2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
Note 3 GST and Income tax TDS will be deducted at a source while making payments of bills
Note 4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017
Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual
mix design the cost of difference of cement consumption have been deducted from the rate of original item at the rate of input rate
mentioned in all the tender.
Deputy Executive Engineer,
Capital Project Sub Division No.10,
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
File No.1 E-Tendering Notice.pdf
File No.2 SBD.pdf
File No.3 BOQ .pdf
File No.4 Specification.pdf
File No.5 Condition GR.pdf
File No.6 Electrical Book.pdf
Download all tender documents and submit your bid