| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹59.3 CrAdmitted-Finance | +0.00% | ₹59.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹66.0 CrAdmitted-Finance | +0.00% | ₹66.0 Cr | L2 | Admitted-Finance |
| 3 | L3₹68.0 CrAdmitted-Finance 434 ALAGAPURAM POST PERUMAL MALAI ADIVARAM SALEM 636004 | SALEM | SALEM | TAMIL NADU | 636004 | +0.00% | ₹68.0 Cr | L3 | Admitted-Finance |
| 4 | L4₹100.0 CrAdmitted-Finance | +0.00% | ₹100.0 Cr | L4 | Admitted-Finance |
Tender Value
₹69.1 Cr
EMD Value
₹1.4 Cr
Closing Date
26 Nov 2025, 5:00 pmClosed
SE CCP I
URJA BHAWAN DEHRADUN
SCADA work under Revamped Distribution Sector Scheme in Uttarakhand State
2025_UPCLC_87464_3
ccp-1/13/2025-2026
Open Tender
Electrical Works
Dehradun
As per Tender Document
5 documents required · 5 mandatory
₹29,500
Executive Engineer, HQ, UPCL
₹1.4 Cr
17 Dec 2025
20 Nov 2025
27 Nov 2025
20 Nov 2025
26 Nov 2025
20 Nov 2025
A1. Project Management Cost
Installation, Testing and Commissioning Cost to Integrate Entire SCADA & IT (relevant to SCADA) Infrastructure
Integration with legacy applications & Data Migration
Training for the Employees
B1. SCADA/DMS control centre Server/ workstation Hardware
SCADA Server
DMS Server
OMS Server
FEP server with interface switches
ISR server
NMS server
DTS server
Developmental server
Commnuication Server
Web/Directory server
SMS gaterway
Workstation with dual TFT Monitors ( S/S monitoring)
Workstation with dual TFT Monitors (Network monitoring)
Remote VDUs with one TFT Monitors
Developmental console with one TFT
DTS/Workstation Console with dual TFTs
DLP Laser/ LED based Video Projection system with 3x4 Module configuration with each module at least 67" diagonal with common projector
Storage & Backup Devices
External RAID Mass storage device ( for 24 months online backup)
Exteranl DAT drive
Switches
Layer II switch (SCADA/DMS LAN)
Layer II switch ( Planning & Development system LAN)
Routers
Router for interfacing IT system & SCADA/DMS DR centre
Router at remote VDU
Security system (DMZ)
Web server with load balancing
Mail server
Router
Firewall & network IDS/IPS
Layer II switch
Other Active Devices
GPS Time synchronisation system
Time, day & date digital displays
Printers
Color laser all in one printer
B/W laser printer
5% of Serial No. 6 to 43 for mandatory spares.
B2. Software for Control Centre
SCADA software
ISR Software
DMS software
OMS Software
ICCP Software
DTS software
Developmental software
Network Management Software
WEB /Network security software (INCL IN WEB SERVER)
RDBMS package
GIS Adaptor/Engine for importing data from GIS system under IT system
C1. SCADA/DMS DR Control Center Server/ workstation Hardware
SCADA Server
DMS Server
OMS Server
FEP server with interface switches
ISR server
NMS server
DTS server
Developmental server
Commnuication Server
Web/Directory server
SMS gaterway
Workstation with dual TFT Monitors ( S/S monitoring)
Workstation with dual TFT Monitors (Network monitoring)
Developmental console with one TFT
DTS/Workstation Console with dual TFTs
DLP Laser/LED based Video Projection system with 3x4 Module configuration with each module at least 67" diagonal with common projector
Storage & Backup Devices
External RAID Mass storage device ( for24 months online backup)
Exteranl DAT drive
Switches
Layer II switch (SCADA/DMS LAN)
Layer II switch ( Planning & Development system LAN)
Routers
Router for interfacing IT system & SCADA/DMS DR centre
Security system (DMZ)
Web server with load balancing
Mail server
Router
Firewall & network IDS/IPS
Layer II switch
Other Active Devices
GPS Time synchronisation system
Time, day & date digital displays
Printers
Color laser all in one printer
B/W laser printer
5% of Serial No. 58 to 93 for mandatory spares.
C2. Software for DR Control Centre
SCADA software
ISR Software
DMS software
OMS Software
ICCP Software
DTS software
Developmental software
Network Management Software
WEB /Network security software
RDBMS package
GIS Adaptor/Engine for importing data from GIS system under IT system
D1. RTUs
RTU base equipment comprising panels, racks, sub-racks, Power Supply modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi
Multifuction Transducers
Contact Multiplying Relays (CMRs)
Heavy duty relays for Control
Dummy Breaker Latching Relays
Transformer Transducers
Single TFT PC for LDMS with table & chair with minimum 4 hrs backup.
Supply, Erection, Testing and commissioning and integration of FO switches in RTU with compatible IEC61850 protocol (Din Rail mounted). Auxiliary Supply: 220VDC or 24 Volts DC as per site requirement.
Supply, Erection,Splicing, testing and commissioning of 12 way LIU Box
supply, Erection, Testing and commissioning of Fiber Optic Steel Grip patch Chords with types of Connectors and length from 3 mts to 15 mts with patch cord couplers duly placing the patch cords in PVC pipe and necessary accossiries as per Site Requirement .
Supply ,erection,testing and commissioning of CAT 6 ethernet cable
5% of Serial No. 108 to 118 for mandatory spares.
D2. Software for LDMS
LDMS software
D3. Test Equipment for RTU
RTU Database Configuration & Maintenance Software tool
Master Station cum RTU Simulator & Protocol analyser software tool
Laptop PC for above software tools along with interfacing hardware including Hub
E1. FRTUs
Mini pole mounted FRTU base equipment along with enclosure suitable to work in open environment (Adequate protection from water & dust) , racks, sub-racks, Power Supply modules with power backup , I/o modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi
Contact Multiplying Relays (CMRs)
Heavy duty relays for Control
Multifunction transducer
5% of Serial No. 127 to 130 for mandatory spares.
E2. Test Equipments for FRTU
FRTU Database Configuration & Maintenance Software tool
Master Station cum FRTU Simulator & Protocol analyser software tool
Laptop PC for above software tools along with interfacing hardware including Hub
Communincation System F1. MPLS
Annual charges for 4 Mbps Links with RTUs and RVDU
MPLS Router
Charges for Aggregated link of 50 Mbps for SCADA control center (Point to point)
Charges for Aggregated link of 50 Mbps for DR center (Point to point)
5% of Serial No. 137 to 140 for mandatory spares.
F2. GPRS
Annual charges for 2MBps Links with FRTUs /FPI
Modems
5% of Serial No. 143 to 144 for mandatory spares.
Auxiliary Power Supply G1. Main Equipments - Control centre
20 KVA UPS with suitable rating running in parallel redundant mode VRLA type Battery banks for UPS for minimum 30 min. backup duration
5% of Serial No. 147 for mandatory spares.
G3. For RTU / Data Concentrator / Communication Eqpts.
DC Power Supply (DCPS) system based on SMPS Battery bank for above DCPS (VRLA Type) for minimum 4 hrs backup
5% of Serial No. 150 for mandatory spares.
G4. For FRTU
DC Power Supply (DCPS) system based on SMPS Battery bank for above DCPS (VRLA Type) for minimum 4 hrs backup
5% of Serial No. 153 for mandatory spares.
G5. Remote VDU location
UPS (2 kVA )
5% of Serial No. 156 for mandatory spares.
SCADA Enabling Components H1. Sectionalizer/Recloser
Recloser
5% of Serial No. 159 for mandatory spares.
Communicable Fault Passage Indicator
5% of Serial No. 162 for mandatory spares.
H3. Control/power cable for RTUs from outdoor switchgear,if any at S/S
Numerial Relays (Compatible with IEC 61850 protocol)
5% of Serial No. 165 for mandatory spares.
I. Setup required for Health Monitoring of Distribution Transformers
Transformer Monitoring Unit (TMU) with any other hardware/software required for communication with SCADA Control center within the MTS
Description of Work / Item(s)
FMS Charges for 05 years
A1. FMS Charges for Project Management Cost
Installation, Testing and Commissioning Cost to Integrate Entire SCADA & IT (relevant to SCADA) Infrastructure
Integration with legacy applications & Data Migration
Training for the Employees
B1. FMS Charges forSCADA/DMS control centre Server/ workstation Hardware
SCADA Server
DMS Server
OMS Server
FEP server with interface switches
ISR server
NMS server
DTS server
Developmental server
Commnuication Server
Web/Directory server
SMS gaterway
Workstation with dual TFT Monitors ( S/S monitoring)
Workstation with dual TFT Monitors (Network monitoring)
Remote VDUs with one TFT Monitors
Developmental console with one TFT
DTS/Workstation Console with dual TFTs
DLP Laser/ LED based Video Projection system with 3x4 Module configuration with each module at least 67" diagonal with common projector
Storage & Backup Devices
External RAID Mass storage device ( for 24 months online backup)
Exteranl DAT drive
Switches
Layer II switch (SCADA/DMS LAN)
Layer II switch ( Planning & Development system LAN)
Routers
Router for interfacing IT system & SCADA/DMS DR centre
Router at remote VDU
Security system (DMZ)
Web server with load balancing
Mail server
Router
Firewall & network IDS/IPS
Layer II switch
Other Active Devices
GPS Time synchronisation system
Time, day & date digital displays
Printers
Color laser all in one printer
B/W laser printer
5% of Serial No. 7 to 44 for mandatory spares.
B2. FMS charges of Software for Control Centre
SCADA software
ISR Software
DMS software
OMS Software
ICCP Software
DTS software
Developmental software
Network Management Software
WEB /Network security software (INCL IN WEB SERVER)
RDBMS package
GIS Adaptor/Engine for importing data from GIS system under IT system
C1. SCADA/DMS DR Control Center Server/ workstation Hardware
SCADA Server
DMS Server
OMS Server
FEP server with interface switches
ISR server
NMS server
DTS server
Developmental server
Commnuication Server
Web/Directory server
SMS gaterway
Workstation with dual TFT Monitors ( S/S monitoring)
Workstation with dual TFT Monitors (Network monitoring)
Developmental console with one TFT
DTS/Workstation Console with dual TFTs
DLP Laser/LED based Video Projection system with 3x4 Module configuration with each module at least 67" diagonal with common projector
Storage & Backup Devices
External RAID Mass storage device ( for24 months online backup)
Exteranl DAT drive
Switches
Layer II switch (SCADA/DMS LAN)
Layer II switch ( Planning & Development system LAN)
Routers
Router for interfacing IT system & SCADA/DMS DR centre
Security system (DMZ)
Web server with load balancing
Mail server
Router
Firewall & network IDS/IPS
Layer II switch
Other Active Devices
GPS Time synchronisation system
Time, day & date digital displays
Printers
Color laser all in one printer
B/W laser printer
5% of Serial No. 59 to 94 for mandatory spares.
C2. FMS Charges for Software for DR Control Centre
SCADA software
ISR Software
DMS software
OMS Software
ICCP Software
DTS software
Developmental software
Network Management Software
WEB /Network security software
RDBMS package
GIS Adaptor/Engine for importing data from GIS system under IT system
D1. FMS Charges for RTUs and components
RTU base equipment comprising panels, racks, sub-racks, Power Supply modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi
Multifunctuions transducers
Contact Multiplying Relays (CMRs)
Heavy duty relays for Control
Dummy Breaker Latching Relays
Transformer Transducers
Single TFT PC for LDMS with table & chair with minimum 4 hrs backup.
Supply, Erection, Testing and commissioning and integration of FO switches in RTU with compatible IEC61850 protocol (Din Rail mounted). Auxiliary Supply: 220VDC or 24 Volts DC as per site requirement.
Supply, Erection,Splicing, testing and commissioning of 12 way LIU Box
supply, Erection, Testing and commissioning of Fiber Optic Steel Grip patch Chords with types of Connectors and length from 3 mts to 15 mts with patch cord couplers duly placing the patch cords in PVC pipe and necessary accossiries as per Site Requirement .
Supply ,erection,testing and commissioning of CAT 6 ethernet cable
5% of Serial No. 109 to 119 for mandatory spares.
D2.FMS Charges for Software for LDMS
LDMS software
D3. FMS Charges for Test Equipment for RTU
RTU Database Configuration & Maintenance Software tool
Master Station cum RTU Simulator & Protocol analyser software tool
Laptop PC for above software tools along with interfacing hardware including Hub
E1.FMS Charges for FRTUs and its compnents
Mini pole mounted FRTU base equipment along with enclosure suitable to work in open environment (Adequate protection from water & dust) , racks, sub-racks, Power Supply modules with power backup , I/o modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi
Contact Multiplying Relays (CMRs)
Heavy duty relays for Control
Multifunction transducer
5% of Serial No. 128 to 131 for mandatory spares.
E2. FMS Charges for Test Equipments for FRTU
FRTU Database Configuration & Maintenance Software tool
Master Station cum FRTU Simulator & Protocol analyser software tool
Laptop PC for above software tools along with interfacing hardware including Hub
FMS Charges for Communincation System F1. MPLS
Annual charges for 4 Mbps Links with RTUs and RVDU
MPLS Router
Charges for Aggregated link of 50 Mbps for SCADA control center (Point to point)
Charges for Aggregated link of 50 Mbps for DR center (Point to point)
5% of Serial No. 138 to 141 for mandatory spares.
F2. FMS Charges for GPRS
Annual charges for 2MBps Links with FRTUs /FPI
Modems
5% of Serial No. 144 to 145 for mandatory spares.
FMS Charges for Auxiliary Power Supply G1. Main Equipments - Control centre
20 KVA UPS with suitable rating running in parallel redundant mode VRLA type Battery banks for UPS for minimum 30 min. backup duration
5% of Serial No. 148 for mandatory spares.
G3. FMS Charges For RTU / Data Concentrator / Communication Eqpts.
DC Power Supply (DCPS) system based on SMPS Battery bank for above DCPS (VRLA Type) for minimum 4 hrs backup
5% of Serial No. 151 for mandatory spares.
G4. II FMS For FRTU
DC Power Supply (DCPS) system based on SMPS Battery bank for above DCPS (VRLA Type) for minimum 4 hrs backup
5% of Serial No. 154 for mandatory spares.
G5. Remote VDU location
UPS (2 kVA )
5% of Serial No. 157 for mandatory spares.
FMS Charges for SCADA Enabling Components H1. Sectionalizer/Recloser
Recloser
5% of Serial No. 160 for mandatory spares.
Communicable Fault Passage Indicator
5% of Serial No. 163 for mandatory spares.
H3. Control/power cable for RTUs from outdoor switchgear,if any at S/S
Numerial Relays (Compatible with IEC 61850 protocol)
5% of Serial No. 166 for mandatory spares.
I. Setup required for Health Monitoring of Distribution Transformers
Transformer Monitoring Unit (TMU) with any other hardware/software required for communication with SCADA Control center within the MTS
Description of Work / Item(s)
Buy Back Hadrware from SCADA Control Center/DR Center & Field Equipment
Racks
8-port KVM Switch
Rack Monitor
Servers
SCAD/DMS Server
FEP server with interface switches
ISR Server
DTS Server
Developmental server
Communication Server
Web/Directory server
Web Server
NMS server
DR Server
DR Communication Server
Visual Projection System
Visual Projection System (With Controller)
C. Laptops
Laptop
E. Firewalls
Firewall
F. GPS System
GPS Receiver
Comparator
Time Display
Date Display
Day Display
Frequency Display
G. Storage
External RAID Storage
H. RTUs & its associated components
Remote Terminal Unit (RTU)
Direct Current Power Supply (DCPS)
Contact Multiplying Relay (CMR)
Multi Function Transducer (MFT)
Heavy Duty Relay (HDR)
Test equipment for FRTUs
Laptop PC for above software tools along with interfacing hardware including Hub
GPRS Modem
Printers
Color laser printer
Auxiliary Power supply
UPS with suitable rating running in parallel redundant mode*(20KVA)
DC Power Supply (DCPS) system based on SMPS
48V DC Power Supply (DCPS) system based on SMPS
UPS (2 kVA )
Miscellaneous/Scrap Items
Details of items are mentioned as attachment 13(C) in the RFP
Description of Work / Item(s)
FMS Charges for 5 Years
FMS charges for SCADA/DMS/OMS system (maintaining overall system availability as per TS)
FMS charges for SCADA/DMS/OMS system (maintaining availability individual hardware & non –critical functions as per TS)
HKRP INNOVATIONS LIMITED (BID ID -406854)
Megawin Switchgear P Limited (BID ID -406893)
VITAL INFRAA PRIVATE LIMITED (BID ID -407045)
HKRP INNOVATIONS LIMITED (BID ID -406854)
Megawin Switchgear P Limited (BID ID -406893)
VITAL INFRAA PRIVATE LIMITED (BID ID -407045)
HKRP INNOVATIONS LIMITED (BID ID -406854)
Megawin Switchgear P Limited (BID ID -406893)
VITAL INFRAA PRIVATE LIMITED (BID ID -407045)
VITAL INFRAA PRIVATE LIMITED (BID ID -407045)
East India Udyog ltd (BID ID -406915)
HKRP INNOVATIONS LIMITED (BID ID -406854)
HKRP INNOVATIONS LIMITED (BID ID -406854)
Megawin Switchgear P Limited (BID ID -406893)
VITAL INFRAA PRIVATE LIMITED (BID ID -407045)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
scadatenderdoc.pdf
Tender Documents • 24.61 MB
MTSRev3.pdf
Other Document • 5.97 MB
Corrigendun.pdf
Other Document • 0.67 MB
corrigendums.rar
Additional Documents • 6.55 MB
BOQ_105575.xls
BOQ • 0.87 MB
Download all tender documents and submit your bid