| # | Company | Amount |
|---|---|---|
| 1 | ₹32.4 Cr E 35 1 KAVI NAGAR INDUSTRIAL AREA GHAZIABAD U P 201002 | ₹32.4 Cr |
Tender Value
₹33.1 Cr
EMD Value
₹33.1 L
Closing Date
5 May 2025, 11:00 amClosed
Construction of Balance Works of Mehta Family School of Data Science and Artificial Intelligence (MFSDSAI) Including Internal Electrical, HVAC, Firefighting, Fire Alarm, Lifts, Audio Visual, CCTV, BMS Installation and Development works at IIT Roorkee Uttarakhand
NBCC/CPG/MFSDSAI/IITR/2025/478
NBCC/CPG/MFSDSAI/IITR/2025/478
Open Tender-Domestic
Civil Works General
Haridwar, Uttarakhand
₹59,000
₹33.1 L
9 Apr 2025
9 Apr 2025
5 May 2025
5 May 2025
4 Jun 2025
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
A SUBHEAD-1 (EARTHWORK)
Carriage of material by mechanical transport including
loading, unloading and stacking
Total earth lead
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over
areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting
out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.
4 2.25 in layers not exceeding 20cm in depth, consolidated each deposited layer by ramming and 1880.87 cum 253.95 4,77,648.08 - 4,77,648.08
watering, lead up to 50m and lift upto 1.5m.
B SUBHEAD-2 (CONCRETE WORKS)
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone
aggregate 20 mm nominal size derived from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone
aggregate 40 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)
including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or
lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken
floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone
aggregate 20 mm nominal size derived from natural sources)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2
7 4.11 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal 10.00 sqm 452.25 4,522.50 - 4,522.50
size derived from natural sources).
Extra for providing and mixing water proofing material in cement concrete work in doses by
weight of cement as per manufacturer’s specification
Digitally signed by ANUJ
Signature of Bidder Page 4 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing & Applying a coat of residual petroleum bitumen of grade of VG-10 of approved
9 4.13 quality using 1.7 kg per square metre on damp proof course after cleaning the surface with 10.00 sqm 113.85 1,138.50 - 1,138.50
brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-
III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from
10 4.17 natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed 204.47 Sqm 681.65 1,39,376.98 - 1,39,376.98
and consolidated and grouted with fine sand, including necessary excavation, levelling &
dressing & finishing the top smooth.
Providing and laying in position ready mixed or site batched design mix cement concrete for
plain cement concrete work; using coarse aggregate and fine aggregate derived from natural
sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in
11 4.2 recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength; including pumping of concrete to site of
laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and
finishing as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be
payable separately. In case the cement content in design mix is more than 110% of the
minimum specified cement content, the contractor shall have discretion to either re-design the
mix or bear the cost of extra cement.
11.1.1 4.20.1 All works upto plinth level
11.1.1.1 4.20.1.1 Concrete of M10 grade with minimum cement content of 220 kg /cum. 204.29 Cum 8,033.20 16,41,077.17 - 16,41,077.17
C SUBHEAD-3 (REINFORCED CONCRETE WORKS)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°
landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral
12 5.3 stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, 34.30 Cum 10,719.30 3,67,661.27 - 3,67,661.27
finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from
natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
12.1 5.9 Centering and shuttering including strutting, propping etc. and removal of form for
12.1.1 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. 397.17 Sqm 307.95 1,22,308.50 - 1,22,308.50
12.1.2 5.9.2 Walls (any thickness) including attached plasters, butteresses, plinth and string courses etc. 1039.70 Sqm 669.55 6,96,131.80 - 6,96,131.80
12.1.3 5.9.3 Suspended floors, roofs, landings, balconies and access platform 184.28 Sqm 766.55 1,41,259.55 - 1,41,259.55
12.1.5 5.9.5 Lintels,beams,plinth beams, girders,bressumers and cantilevers. 20.69 Sqm 608.35 12,586.76 - 12,586.76
12.1.6 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. 1310.40 Sqm 804.25 10,53,889.20 - 10,53,889.20
12.1.7 5.9.7 Stairs, (excluding landings) except spiral-staircases. 54.94 Sqm 657.75 36,136.79 - 36,136.79
12.1.8 5.9.19 Weather shade, Chajjas, corbels etc., including edges. 5.00 Sqm 814.95 4,074.75 - 4,074.75
Extra for additional height in centering, shuttering where ever required with adequate bracing,
13 5.11 propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5
m, for every additional height of 1 metre or part thereof (Plan area to be measured)
13.1 5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 90.00 Sqm 319.25 28,732.50 - 28,732.50
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level.
14.1 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. 22000.00 Kg 89.65 19,72,300.00 - 19,72,300.00
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
Digitally signed by ANUJ
Signature of Bidder Page 5 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
15.1 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. 131000.00 Kg 89.65 1,17,44,150.00 - 1,17,44,150.00
16 5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 50.00 meter 64.70 3,235.00 - 3,235.00
Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength; including pumping of concrete to site of
laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing
and reinforcement as per direction of the engineer-in-charge; for the following grades of
17.1 5.33.1 All works up to plinth level.
17.1.1 5.33.1.2 Concrete of M30 grade with minimum cement content of 350 kg /cum 250.00 cum 8,825.35 22,06,337.50 - 22,06,337.50
17.2 5.33.2 All works above plinth level upto floor V level
17.2.1 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum 929.00 cum 10,306.20 95,74,459.80 - 95,74,459.80
17.2.2 5.33.2.4 Concrete of M40 grade with minimum cement content of 390 kg /cum 250.01 cum 10,730.90 26,82,779.73 - 26,82,779.73
DSR Item Extra For Concrete of M30 grade with minimum cement content of 350 kg /cum in place of
(5.33.2.2- Concrete of M30 grade with minimum cement content of 350 kg /cum
17.2.5 5.33.2.5 Concrete of M50 grade with minimum cement content of 410 kg /cum 500.00 cum 10,872.50 54,36,250.00 - 54,36,250.00
D SUBHEAD-4 (BRICK WORK)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in:
18.1 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 2.00 Cum 6,658.25 13,316.50 - 13,316.50
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of
half brick masonry
Brick work with clay fly ash F.P.S. (non modular) brick of class designation 7.5 in
superstructure above plinth level up to floor five level in :
20.1 6.32.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 1.00 Cum 8,190.90 8,190.90 - 8,190.90
Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS
:12894, in super structure above plinth and upto floor V level
21.1 6.45.2 Cement mortar 1:4 (1 cement :4 coarse sand) 2.00 Sqm 969.65 1,939.30 - 1,939.30
Providing and laying autoclaved aerated cement blocks masonry with 100mm thick AAC
blocks in super structure above plinth level up to floor First level in cement mortar 1:4 (1
cement : 4 coarse sand ) The rate includes providing and placing in position 2 Nos. 6 mm dia
M.S. bars at every third course of masonry work.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm
thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill
23 6.47 level and lintel level with approved block laying polymer modified adhesive mortar all complete 1078.23 Cum 6,994.15 75,41,324.39 - 75,41,324.39
as per direction of Engineer-in- Charge. (The payment of RCC band and reinforcement shall be
made for seperately).
E SUBHEAD-5 (STRUCTURAL STEEL WORK)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work,
24 10.2 including cutting, hoisting, fixing in position and applying a priming coat of approved steel 2834.32 kg 111.95 3,17,302.52 - 3,17,302.52
primer all complete.
Digitally signed by ANUJ
Signature of Bidder Page 6 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position and applying a priming coat of approved steel
primer, including welding and bolted with special shaped washers etc.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in
26 10.25 position and applying a priming coat of approved steel primer using structural steel etc. as
26.1 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 13835.55 Kg 142.30 19,68,798.05 - 19,68,798.05
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of
10mm dia double threaded 6.8 grade (yield strength 480 N/mm2 ), counter sunk head,
comprising of 10m dia polyamide PA 6 grade sleeve, including drilling of hole in frame,
concrete/ masonry, etc.as per direction of Engineer-in-charge
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates
etc., including welding, grinding, buffing, polishing and making curvature (wherever required)
and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing
28 10.28 with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required 1734.48 Kg 612.25 10,61,933.11 - 10,61,933.11
size, on the top of the floor or the side of waist slab with suitable arrangement as per approval
of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
F SUBHEAD-5 (STONE WORK)
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished)
machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations
of required size of approved shade, colour and texture laid over 20mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete at all levels.
29.1 8.2.2 Granite stone slab of colour black, Cherry/Ruby red
Providing edge moulding to 18mm thick marble/Granite stone counters, Vanities etc. including
30 8.3 machine polishing to edge to give high gloss finish etc. complete as per design approved by
Engineer-in- Charge.
Extra for fixing marble /granite stone over and above corresponding basic item, in facia and
drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen
platform, vanity counters and similar location in marble/Granite/stone work including
necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc.
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement
: 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
33.1 8.9.1 8mm thick
Digitally signed by ANUJ
Signature of Bidder Page 7 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang
saw cut stone with machine cut edges of uniform colour and size upto 1m x 1m,
fixed to structural steel frame work and/ or with the help of cramps, pins etc. and
34 8.20 sealing the joints with approved weather sealant as per Architectural drawing
and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps
and pins etc. shall be paid for separately).
34.1 8.20.2 White sand stone - 30mm thick gang saw cut stone
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut
with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube
in the required pattern as per architectural drawing, including cost of cutting, bending, welding
etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/
flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete
block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size
300x230x300 mm, including cost of necessary centring and shuttering and with approved
expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved
cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work
will be given a priming coat of Zinc primer as approved by Engineerin-charge and painted with
two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the
Engineer-in- charge for approval before execution). The frame work shall be fixed in true
horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the
purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and
size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms),
36 8.22 for dry stone cladding fixed on frame work at suitable location, including making necessary 3565.00 Each 365.65 13,03,542.25 - 13,03,542.25
recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium
37 8.32 Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the
building , for all heights and all levels etc. including:
Structural analysis & design and preparation of shop drawings for pressure equalisation or rain
(a) screen principle as required, proper drainage of water to make it watertight including checking
of all the structural and functional design.
Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding
in pan shape in metalic colour of approved shades made out of 4mm thick aluminium
composite panel material consisting of 3mm thick FR grade mineral core sandwiched between
two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet
shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating
of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as
specified using stainless steel screws, nuts, bolts, washers,
cleats, weather silicone sealant, backer rods etc.
Digitally signed by ANUJ
Signature of Bidder Page 8 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with
serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and
anchor bolts of approved make in SS 316, Nylon separators to prevent bi- metallic contacts all
complete required to perform as per specification and drawing The item includes cost of all
material & labour component, the cost of all mock ups at site, cost of all samples of the
individual components for testing in an approved laboratory, field tests on the assembled
working curtain wall with aluminium composite panel cladding, cleaning and protection of the
37.1 (c) curtain wall with aluminium composite panel cladding till the handing over of the building for 1171.68 Sqm 4,474.20 52,42,314.08 - 52,42,314.08
occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s
The Contractor shall provide curtain wall with aluminium composite panel cladding, having all
the performance characteristics all complete , as per the Architectural drawings, as per item
description, as specified, as per the approved shop drawings and as directed by the Engineer-in-
Charge. However, for the purpose of payment, only the actual area on the external face of the
curtain wall with Aluminum Composite Panel Cladding (including width of groove)
shall be measured in sqm. up to two decimal places.
G SUBHEAD-5 (FLOORING WORK)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished
38 11.3 with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of
steps etc. complete.
38.1 11.3.1 40mm thick with 20mm nominal size stone aggregate. 313.86 Sqm 545.00 1,71,050.98 - 1,71,050.98
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey
cement slurry mixed with pigment to match the shade of the slab including rubbing and
polishing complete with base of
cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm
40 11.27 (average) thick cement mortar 1:3 (1 cement 3coarse sand) and jointed with grey cement slurry 30.18 Sqm 2,038.55 61,524.48 - 61,524.48
mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1
cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement
: 2 stone dust) admixed with pigment to match the shade of stone and pointing with same
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved
brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1
cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the
joints with white cement and matching pigments etc. The tiles must be cut with the zero
chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber mallet for placing the tiles gently and
42.1 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
Digitally signed by ANUJ
Signature of Bidder Page 9 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the
manufacturer), with water absorption less than 0.08%and conforming to IS: 15622, of approved
brand & manufacturer in all colours and shade in skirting, riser of steps, laid with cement based
high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in
average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made
Providing and fixing removable raised/false access flooring with system and its components of
approved make for different plenum height with possible height adjustment upto 50 mm,
44 11.54 comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame
work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as
directed by Engineer-in-charge consisting of:
Providing at required spacing to form modular framework, pedestals made out of GI tube of
thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of
size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size
75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI
Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the
pedestal head in position at the required level. The pedestals shall be fixed to the subfloor
(base) through base plate using epoxy based adhesive of approved make or the
machine screw with rawl plug.
Stringers system in all steel construction hot dipped galvanized of rectangular size
570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the
pedestal head using fully threaded screws ensuring maximum lateral stability in all directions,
the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system
shall provide adequate solid, rigid support for access floor panel, the system shall provide a
minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits
and wiring etc. all complete as per the architectural drawings, as specified and as
directed by the Engineer-in-charge.
Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti
static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel
welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical
cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot
welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel
should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and
bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with
(c) lightweight foaming compound. The access floor shall be factory finished with Anti-static High
Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and
Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs
applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on
four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum
1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers
specification and as per the direction of Engineer-in- charge. All specification must be printed
on the side of the panel to ensure the quality of the product.
Digitally signed by ANUJ
Signature of Bidder Page 10 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and laying flamed finish Granite stone flooring in required design and patterns, in
linear as well as curvilinear portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4
(1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement
slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge :
45.1 11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 373.60 Sqm 2,589.90 9,67,580.52 - 9,67,580.52
Providing and laying Polished Granite stone flooring in required design and patterns,in linear
as well as curvilinear portions of the building all complete as per the architectural drawings
with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 (1 cement:4
coarse sand) laid and jointed with cement slurry and pointing with white cement slurry
admixed with pigment of matching shade including rubbing , curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge.
46.1 11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 3706.16 Sqm 3,908.80 1,44,86,641.60 - 1,44,86,641.60
H SUBHEAD-5 (FINISHING WORK)
47 13.1 12 mm cement plaster of mix :
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5
coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
49 13.16 6 mm cement plaster of mix :
50 13.37 White washing with lime to give an even shade :
Distempering with oil bound washable distemper of approved brand and manufacture to
give an even shade :
New work (two or more coats) over and including water thinnable priming coat with
52 13.50 Applying priming coat:
With ready mixed pink or Grey primer of approved brand and manufacture on wood work
(hard and soft wood)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per
53 13.52 manufacturer's specifications including appropriate priming coat, preparation of surface, etc.
Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5
54 13.58 sqm per litre per coat including preparation of base surface as per recommendations of 52.80 Sqm 285.80 15,090.24 - 15,090.24
manufacturer to make the surface fire retardant.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to
give an even shade :
Two or more coats on new work over an under coat of suitable shade with ordinary paint of
approved brand and manufacture
Providing and applying white cement based putty of average thickness 1 mm, of approved
56 13.80 brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth 10756.00 Sqm 123.85 13,32,130.37 - 13,32,130.37
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile
57 13.83 Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture,
including applying additional coats wherever required to achieve even shade and colour.
Digitally signed by ANUJ
Signature of Bidder Page 11 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
I SUBHEAD-9 (ALUMINIUM WORK)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia
and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with
required EPDM rubber/neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically
wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.
brass/ stainless steel screws, all complete as per architectural drawings and the directions of
Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for
58.1 21.1.1 For fixed portion
58.1.1 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 678.65 Kg 466.30 3,16,455.66 - 3,16,455.66
Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to
roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and
stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per
direction of Engineer -in-charge.
Providing and fixing double glazed hermetically sealed glazing in aluminium windows,
ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air
gap, including providing EPDM gasket, perforated aluminium spacers, desiccants,
sealant (Both primary and secondary sealant) etc. as per specifications, drawings and
direction of Engineer-in-
charge complete.
Providing and fixing anodised aluminium grill /louver (anodised transparent or dyed to
required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of
approved design/pattern, with approved standard section and fixed to the existing window
frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the
grill to proper opening size for fixing and operation of handles and fixing approved anodised
aluminium standard section around the opening, all complete as per requirement and direction
of Engineer-in-charge.
(Only weight of grill to be measured for payment).
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand
and manufacture, including providing and fixing top & bottom pivot & spring type fixing
arrangement and making necessary holes etc. for fixing required door fittings, all complete as
per direction of Engineer- incharge (Door handle, lock and stopper etc.to be paid separately).
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/
Stone/wood/Ceramic/Gypsum work by providing weather/structural non sag elastomeric PU
sealant over backer rod of approved quality as per architectural drawings and direction of
Engineer-in- charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600
J SUBHEAD-10 (STRUCTURAL GLAZING AND ALUMINIUM COMPOSITE PANEL)
Digitally signed by ANUJ
Signature of Bidder Page 12 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and supplying aluminium extruded tubular and other aluminium sections as per the
architectural drawings and approved shop drawings , the aluminium quality as per grade 6063
T5 or T6 as per BS 1474,including super durable powder coating of 60- 80 microns
conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-
Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for
fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
The weight of aluminium extruded section shall be taken for purpose of
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized
65 25.2 system of structural glazing (with open joints) for linear as well as curvilinear portions of the
building for all heights and all levels, including:
Structural analysis & design and preparation of shop drawings for the specified design loads
conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind
pressure without any failure), including functional design of the aluminum sections for fixing
glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets,
screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire
stop (barrier)cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure
equalisation & drainage and protection against fire
hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5
brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement
for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/
masonry/structural steel framework of building structure using stainless steel anchor fasteners/
bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless
steel grade 316, of the required capacity and in required numbers.
Providing and filling, two part pump filled, structural silicone sealant and one part weather
silicone sealant compatible with the structural silicone sealant of required bite size in a clean
and controlled factory / work shop environment, including double sided spacer tape, setting
blocks and backer rod, all of approved grade, brand and manufacture, as per the approved
sealant design, within and all around the perimeter for
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes,
(d) shapes and profiles, as required as per the site conditions, to seal the gap between the building
structure and all its interfaces with curtain glazing to make it watertight.
Digitally signed by ANUJ
Signature of Bidder Page 13 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Making provision for drainage of moisture/ water that
enters the curtain glazing system to make it watertight, by incorporating principles of pressure
equalization, providing suitable gutter profiles at bottom (if required), making necessary holes
of required sizes and of required numbers etc. complete. This item includes cost of all inputs
of designing, labour for fabricating and installation of aluminium grid, installation of glazed
units, T&P, scaffolding and other incidental charges including wastages etc., enabling
temporary structures and services, cranes or cradles etc. as described above and as specified.
The item includes the cost of getting all the structural and functional design including shop
drawings checked by a structural designer, dully approved by Engineer-in- charge. The item
also includes the cost of all mock ups at site, cost of all samples of the individual components
for testing in an approved laboratory, field tests on the assembled working structural glazing as
specified, cleaning and protection till the handing over of the building for occupation. In the
end, the Contractor shall provide a water tight structural glazing having all the performance
characteristics etc. all complete as required, as per the Architectural drawings, as per item
description, as specified, as per the approved shop drawings and as directed by the
Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded
aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof
stainless steel wire mesh shall be paid for separately under relevant items under this sub- head.
However, for the purpose of payment, only the actual area of structural glazing (including
width of grooves) on the external face shall be measured in
sqm. up to two decimal places.
Note:-2. The following performance test are to be
conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from
the certified laboratories accreditated by NABL(National Accreditation Board for Testing and
Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is
payable separately.
The NIT approving authority will decide the necessity of testing on the basis of cost of the
work, cost of the test and importance of the work. Performance Testing of Structural glazing
system Tests to be conducted in the NABL accredited lab or any other accreditation body
which operates in accordance with ISO/ IEC
17011 and accredits labs as per ISO/IEC 17025
Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as
per ASTM E- 283-04 testing method for a range of testing limit 1 to 200 mVhr
Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a
range up to 2000 ml.
Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a
range upto 2000 ml
Structural Performance Deflection and deformation by static air pressure test (1.5 times design
4 wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50
Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative
test, Tests to be conducted on site.
65.1 6 Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml 1252.07 Sqm 3,111.35 38,95,615.55 - 38,95,615.55
Digitally signed by ANUJ
Signature of Bidder Page 14 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Extra for openable side / top hung vision glass panels (IGUs) including providing and
supplying at site all accessories and hardwares for the openable panels as specified and of the
approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking
sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/
fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the
approved shop drawings, as specified and as directed by the Engineer- inCharge.
Providing, fabricating and supplying shadow box of required size and shape, for fixing in the
spandrel portion of the structural glazing, in linear as well as curvilinear portions of the
building by providing semi - rigid, inorganic, non-combustible fibre glass wool insulation 50
mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing
67 25.5 (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre 2.88 Sqm 1,954.30 5,628.38 - 5,628.38
glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of
randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5
mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets,
nuts, bolts, washers etc complete.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened
monolithic float glass of approved colour and shade with reflective soft coating on surface # 2
of approved colour and shade so as to match the colour and shade of the IGUs in the vision
panels etc. ,all complete for the required performances as specified, as per the Architectural
drawings, as per the approved shop drawings, as specified, and as directed by the Engineer-
For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area
of grooves and weather silicone sealant) provided and fixed in position, shall be measured in
sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of
relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating
on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light
reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-
0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be
decided by technical sanctioning authority as per the site requirement.
K SUBHEAD-11 (WATER PROOFING WORKS)
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for
69 22.4 construction/ expansion joints between two RCC members and fixed to the reinforcement with
binding wire before pouring concrete etc. complete :
69.1 22.4.2 Dumb bell with central bulb (180mm wide, 8mm thick). 30.00 Metre 232.05 6,961.50 - 6,961.50
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by
applying cement slurry mixed with water proofing cement compound consisting of applying :
First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound
@ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement
(b) compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with
water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions
of pipes and masonry with polymer mixed slurry
Digitally signed by ANUJ
Signature of Bidder Page 15 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and laying integral cement based water proofing treatment including preparation of
71 22.7 surface as required for treatment of roofs, balconies, terraces etc consisting of following
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water
proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC
slab including adjoining walls upto 300 mm height including cleaning the surface before
Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50%
of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement
(b) mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating
similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and
After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of
(c) cement admixed with water proofing compound conforming to IS : 2645 and approved by
Engineer-in-charge.
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse
sand) admixed with water proofing compound conforming to IS : 2645 and approved by
(d) Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster
and finally finishing the surface with trowel with neat cement slurry and making pattern of
300x300 mm square 3 mm deep.
The whole terrace so finished shall be flooded with water for a minimum period of two weeks
(e) for curing and for final test.“All above operations to be done in order and as directed and
specified by the Engineer-in- Charge :
71.1 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 1117.01 Sqm 1,522.95 17,01,152.95 - 17,01,152.95
72 22.14 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal
L SUBHEAD-12 (WOOD, PVC WORK & FIRE DOORS WORK)
Providing wood work in frames of doors, windows, clerestory windows and other frames,
73 9.1 wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia
& length ( hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed
shutters for doors, windows and clerestory windows (Area of opening for panel inserts
excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled
and glazed shutters 25 mm to 40 mm thick :
74.1 9.7.7 Float glass panes
74.1.1 9.7.7.1 4 mm thick glass pane (weight not less than 10kg/sqm). 0.68 Sqm 1,897.10 1,280.54 - 1,280.54
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-
decorative type, core of block board construction with frame of 1stclass hard wood and well
matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on
both faces of shutters :
75.1 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 101.64 Sqm 2,015.75 2,04,875.79 - 2,04,875.79
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all
edges of flush door shutters (over all area of door shutter to be measured).
Digitally signed by ANUJ
Signature of Bidder Page 16 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass
excluded) (overall area of door shutter to be measured):
78 9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 46.53 Sqm 93.65 4,357.53 - 4,357.53
Providing and fixing wooden moulded beading to door and window frames with iron screws,
plugs and priming coat on unexposed surface etc. complete :
79.1 9.40.1 2nd class teak wood
80 9.75 Providing and fixing bright finished brass door latch with necessary screws etc. complete :
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair
of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door
closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to
80 kg and door width from 701 mm to 1000mm) with double speed adjustment with necessary
accessories and screws etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six
83 9.103 levers anda pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) 112.00 Each 739.80 82,857.60 - 82,857.60
aluminium lever handles of approved quality with necessary screws etc. complete.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss /
matt / suede finish with high density protective surface layer and reverse side of adhesive
bonding quality conforming to IS : 2046 Type Including cost of adhesive of approved
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC
multi- chambered frame with in-built roller track and sash extruded profiles duly reinforced
with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of
required length (shape & size according to uPVC profile), appropriate dimension uPVC
extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if
required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one
side of extreme panels along with zinc plated mild steel multi point locking having transmission
gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS
85 9.147F 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg),
G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel
screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners,
including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame
the gap between frame and adjacent finished wall shall be filled with weather proof silicon
sealent over backer rod of required size and of approved quality, all complete as per approved
drawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon
sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted
but no extra payment on thisaccount shall be made.
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in
depth & width of profile shall be acceptable.
Three track three panels sliding door made of (big series) frame 116 x 45 mm & sash 46 x 82
85.1 9.147F.3 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead 14.95 Sqm 6,940.45 1,03,759.73 - 1,03,759.73
of appropriate dimension. (Area of door above 5.00 sqm)
Digitally signed by ANUJ
Signature of Bidder Page 17 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate
made out of 16 SWG G.I.sheet (zinc coating not less than 120gm/sqm) duly filled with
vermuculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters.
86 9.136 The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the 103.60 Metre 1,462.75 1,51,540.90 - 1,51,540.90
frame and fixing with dash fastener of approved size and make, including applying a coat of
approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash
fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 120 minutes fire rating
conforming to IS:3614 (Part-II) tested and certified as per laboratory approved by Engineer-in-
charge with suitable mounting on doorframe, consisting of vertical styles, lock rail, top rail
87 9.137 100mm wide, bottom rail200mm wide, made out of 16 SWG G.I.sheet (zinc coating not less 69.23 Sqm 6,444.95 4,46,183.89 - 4,46,183.89
than 120 gm/sqm duly filled FR insulation material and fixing with necessary stainless steel ball
bearing hinges of approved make, including applying a coat of approved fire resistant primer
etc. all complete as per direction of Engineer-in charge(pannelling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with
G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size
20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150
mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less
than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all
respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge
with glass of required thickness having 60 minutes of fire resistance both integrity & radiation
control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give
test report/certification of fire glass and the glass should have the stamp showing the value ofE,
EW & EI. The glass shall be tested in approved NABL accredited lab or by any other
accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per
ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size
not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point)
89 9.139 fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand 15.00 Each 7,145.90 1,07,188.50 - 1,07,188.50
and manufacture to be approved by the Engineer- in- charge, all complete.
M SUBHEAD-13 (ROOFING)
Providing gola 75X75 mm in cement mortar 1:2:4 (1 cement : 2 Coarse sand : 4 stone
90 12.21 aggregates 10 mm down ) including finishing with cement mortar 1:3 (1 cement : 3 fine sand )
as per standard design :
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C.
91 12.22 sheet1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and 8.00 Each 266.60 2,132.80 - 2,132.80
a coat of neat cement, rounding the
edges and making and finishing the outlet complete.
Digitally signed by ANUJ
Signature of Bidder Page 18 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium
silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level,
suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @
120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints
to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet,
spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm
(Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a
grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of
0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to
from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle
pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the
help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm
interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved
texture in the grid, including, cutting/ making opening for services like diffusers, grills, light
fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended
from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia
and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of
size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed
with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as
per specifications, drawings and as directed by Engineer-in-Charge.
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No
deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30
sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection
> 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having
thermal conductivity <0.043w/mv
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI
(solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof
and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1
93 12.55 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in 1139.97 Sqm 1,444.90 16,47,145.09 - 16,47,145.09
ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including
providing skirting upto 150 mm height along the parapet walls in the same
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free
Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam
being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6- 8 sqm per litre, laying
94 12.56 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement 1117.01 Sqm 1,363.95 15,23,548.09 - 15,23,548.09
screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered
rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the
joints with polymerized mastic, all complete as per direction of Engineer-in-Charge.
N SUBHEAD-14 (MISCELLANEOUS NON SCHEDULED ITEMS - CIVIL WORK)
Digitally signed by ANUJ
Signature of Bidder Page 19 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing & applying intumescent fire retarding coating of approved make in minimum
thickness of required thickness as per design for fire nrating of 2 hour/120 minutes to exposed
steel work at any height in its finally eracted position as per manufacturer's recommendations
for surface treatment and application including primer cross beams sprayed in position & at site
including all scaffolding, primer, finish coat & ancillary tools machinery required all as per
manufacture's recommendation & certification, etc all completed to the entire satisfaction of
95 N.S Project Manager. Intumescent coating shall be very low VOC, single component, acrylic, 657.40 Sqm 2151.00 - 14,14,061.12 14,14,061.12
intumescent heat insulation paint providing excellent fireproof performance, good film
appearance and easy application providing very effective fire barrier due to high active solid
content of minimum 63% plus munus 4% char strength and nano fillers and shall have
minimum density of 1.30 kg/l intumescent coating shall be such which shall provide fast
development of stable, low heat transfer sa as to provide effective and long term pretection to
flammable and non-flammable substrates.
Providing and Applying passive fire protection complying to UL 263/ ASTM/ BS 476 for
composite steel strcuture by supplying & installing non-corrosive, Spray Applied Cementitious
Fireproofing Vermiculite, consisting of factory controlled premixed cement with a minimum
dry density of 350 kg/cum and installed by manufacturer/ supplier approved applicator. Spray
shall be done in one or more coats of approved make for a two-hour fire protection rating on
structural steel members/sections of different shapes and sizes at all locations. The coating
should be asbestos-free & non- gypsum-based (gypsum-based fireproofing material is not
acceptable). The thickness of fireproofing is to be dependent on Hp/A or W/D or A/P as the
case may be & as calculated by the manufacturer& approved by the Engineer In charge. The
minimum thickness of fire protection coating to be applied on structural steel of different
shapes and sizes shall be 17 mm and above irrespective of as calculated by the manufacturer to
achieve two-hour fire protection and to withstand thermal shocks up to 550 Degree Centigrade.
Structural steel surface members shall be manually cleaned by wire brush to ensure all it is free
of oil, grease, loose mill scale, dirt, dust, or other materials that would impair the bond of
coating to the surfacebefore the application of the fire protection coating. The fire protection
coating of specified thickness shall be achieved by applying the material to the structural steel
surface by spraying method after mixing the material in the recommended quantity of water to
achieve the targeted density. The material thickness should be calculated and shall conform to
fire protection requirements of either BS 276 or UL 263 or ASTM E119 or EN in unrestrained
assembly conditions. The contractor shall furnish test report from the International Test
Laboratory of material before execution of work. Item includes cost of all tools, tackles,
machinery; scaffolding, proper storage of material etc. required to complete activity & nothing
shall be paid extra. Actual surface area of structural steel members shall only be measured for
Digitally signed by ANUJ
Signature of Bidder Page 20 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and fixing of Carpet tile with size of 500X500 mm as per Specification-
1) Yarn / Fibre 100%- Recycled Solution Dyed Nylon
2) Colour System-100% Solution Dyed & 100% Nylon
3) Soil/Stain Protection-Protekt²
4) Preservative Protection-Intersept
5) Tufted Pile Weight -12 - 18 oz/yd² ±5% || 475 - 610 g/m² ±5%
7) Pile Thickness -2 - 3 mm ± 0.5mm
8) Total Thickness - 5-6 mm ± 0.5mm
9)Size Description -25cm X 1m or 500 X 500mm
10) Backing Structure-GlasBac backing with Reinforced Galswwol backing.
11) Adhesive used- Water based Adhesive to be used.
All Complete as per direction of engineer-in charge
Providing and fixing unglazed, uncoated, metal pressed, full body homogeneous anti-algal, all
weather resistant ready to install step tile with built-in- bull nose and anti skid strip, smooth and
anti skid surface confirming to IS: 4457-2007 and having water absorption of <0.05% in 12mm
thickness with size of 2000mm x 300mm, 1520mm x 300mm, 1200mm x 300mm, 920mm x
300mm or in sizes as required as per site condition in treads of stairs. These anti skid tiles are
to be laid on 20mm thick cement mortar of mix 1:4 (1 cement: 4 coarse sand) and joints filled
with polymer based cement grout with all labour, material, cement, tile, sand, grout etc as a
Providing and fixing unglazed, uncoated, metal pressed, full body homogeneous anti-algal, all
weather resistant ready to install step tile with built-in- bull nose and anti skid strip, smooth and
anti skid surface confirming to IS: 4457-2007 and having water absorption of <0.05% in 12mm
thickness with size of 2000mm x 300mm, 1520mm x 310mm, 1200mm x 300mm, 920mm x
300mm or in sizes as required as per site condition in treads of stairs. These anti skid tiles are
to be laid on 20mm thick cement mortar of mix 1:4 (1 cement: 4 coarse sand) and joints filled
with polymer based cement grout with all labour, material,cement, tile, sand, grout etc as a
Providing and fixing unglazed, uncoated, metal pressed, full body homogeneous anti-algal, all
weather resistant ready to install step tile with built-in- bull nose and anti skid strip, smooth and
anti skid surface confirming to IS: 4457-2007 and having water absorption of <0.05% in 12mm
thickness with size of 2000mm, 1520mm, 1200mm, 920mm in length and 150mm-200mm
wide or in sizes as required as per site condition in riser and skirting of stairs. These anti skid
tiles are to be laid on 12mm thick cement mortar of mix 1:3 (1 cement: 3 coarse sand ) and
joints filled with polymer based cement grout with all labour, material, cement, tile, sand, grout
etc as a complete job
Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water
absorption less than 0.06% and conforming to IS:15622, of approved make, brand and
manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing
with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and
100(A) N.S matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. 308.12 Sq.m 3623.95 - 11,16,629.29 11,16,629.29
Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness,
vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and
Size of tile 800x2400mm of all colours and shades
Digitally signed by ANUJ
Signature of Bidder Page 21 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the
manufacturer),with water absorption less than 0.08% and conforming to IS:15622, of approved
101 N.S brand & manufacturer in all colours and shade in wall cladding ,laid with cement based high
polymer modified quick set tile adhesive (water based) conforming to IS:15477 execution as
per Engineer_in_charge.
Providing and fixing in position Acoustical wall panelling with cladding of walls with fabric
cladded glass wool acoustical panels of 25 mm thickness above 7 feet from floor level and
102 N.S prelaminated MDF/HDF/particle board based perforated acoustic panels fixed on GI sections 114.71 Sq.m 4925.00 - 5,64,936.90 5,64,936.90
upto 7 feet from floor level including GI metal framing in hall and alike locations as per
direction of engineer_in_charge.
Supply and installation at site 35 mm thick GLASS FIBRE REINFORCED CONCRETE JALI,
produced in accordance with PRE CAST INSTITUTE(U.S.A) MANUAL 128 EDN
103 N.S 4,conforming to approved drawings. Product manufactured using compositions of Alkali 0.00 Sqm 3450.00 - - -
Resistant Glass Fibers, High Silica Sand and white cement as raw materials.( Conforming to
relevant Indian and ASTM standards)
Providing and Fixing UniStone CFP – Clay Façade Panelling system in approved shade, finish,
size and in thickness of 15mm. The clay panels shall have Flexural Strength /Modulus of
rupture ≥ 9 N /mm2 in accordance to ISO – 10545 -4 with breaking strength ≥ 550 N in
accordance to ISO 10545-4. The panels should have water absorption ≤ 4 % in accordance to
ISO – 10545-3. The surface scratch hardness value i.e., Moh’s scale should be Minimum 6 in
accordance to ISO -10545-2. The clay panels should have inherent properties of being resistant
to stains and chemicals. The material should be Class I material in terms of reaction to fire in
accordance to EN 13501-1 / ASTM E136. The entire system should be certified by an
approved third-party structural consultant for a minimum structural proof load test with positive
& negative wind pressure of 5kPA.The cladding panels shall be fixed on to existing cured
plastered surface substrate wall treated with one or two coats of primer with appropriate
Aluminium rectangular hollow section vertical members framework of 25mm X 50mm (2mm
thick) which shall be spaced out in accordance to the dimensions of the panel with minimum
104 N.S. spacing of 600mm. The framework shall be attached through L shaped aluminium connectors
of 25mm X 37mm (2mm thick) to the substrate walls. The manufactured panels shall have an
evenly controlled factory – made groove for resting on to a continuous aluminium rail profiles
throughout their length. The profiles are designed and manufactured for starter piece,
intermediate and an inverted starter profile for the top piece. Aluminium rail profile shall
ensure uniform and precision joints and shall be factory finished with Super Durable powered
coated colour in approved RAL shade. All fixtures, and screws shall be corrosion free i.e., all
rail profiles, cleats to be used should be made of 6063 T6 alloy grade and all screws used
should be of Stainless steel of M/s Hilti, Worth, Klimas, Patta or equivalent. The groove of the
width can be chosen i.e., 1.7mm, 3mm, 6.5mm, 12.6mm or 20mm. The corners junctions to be
neatly treated with adequate aluminium closed ‘L’ corner shaped pieces in required length in
similar shadecoated with factory finished Super Durable Powder, to the clay façade panel.
Alternatively, the corners junctions can be treated as regular corner fixing or Mitred corner
fixing. All fixing details and drawings to be provided by vendor and to be duly approved by
All fixing details and drawings to be provided by vendor and to be duly approved by Engineer
104.1 in charge at project.All fixing details and drawings to be provided by vendor and to be duly 1145.58 Sqm 7854.00 - 89,97,383.44 89,97,383.44
approved by Engineer in charge at project.
Digitally signed by ANUJ
Signature of Bidder Page 22 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
FACADE/WINDOW GLASS: Designing, Providing, assembling and supplying vision glass
panels (IGUs) comprising of hermetically-sealed 28mm thick D.G.U. consisting of outer 6mm
high performance toughened green tint glass having performance parameters as mentioned +
16 mm air gap + inner 6mm toughened clear Glass with low ppm level of less than 700 ppm
vision panel units of size and shape as required and specified, of approved colour and shade
with reflective soft coating on surface # 2 , spacer tube 12mm wide, including primary seal and
secondary seal (structural silicone sealant) etc. all complete for the required performances, as
per the Architectural drawings, as per the approved shop drawings, as specified and as directed
by the Engineer-in-Charge. The DGUs shall be assembled in the factory/ workshop of the glass
processor.“(Payment for fixing of DGU Panels in the curtain glazing is included in cost of
relevant item )“For payment, only the actual area of glass on face # 1 of the glass panels
(including the areas of the grooves and weather silicone sealant)provided and fixed in position,
measured in sqm.“.
Providing and applying One coat of natural shade with stone dust tinted trowel texture in
approved shade over a coat of base texture that is a natural shade texture with stone dust
without chips over a coat acrylic primer Mixed with wall sealer along with repair check with
exterior grade cement mixed with primer , one coat of siloxane protection coat to be applied
over this, as directed by Engineer-In-Charge.
EXTERNAL TEXTURE FINISHES : THICKNESS : 1.25 -1.5 MM
Providing & Fixing tegular edge and 15 mm thickness,easily demountable tile , visible surface
of each tile is 7 mm below the grid, manufactured from High density glass wool , visible
surface is a batch painted glass tissue in white, back of the tile covered with glass tissue. Size
Acoustics-Sound absorption(Alpha W) - 0.95 at 200 mm overall depth of system as per EN ISO
354 Acoustics-Sound absorption Class - Class A at 200 mm overall depth of system as per EN
ISO 11654 Acoustics-Articulation class - 180 as per ASTM E1111, ASTM E1110 NRC - 0.9
NRC as per ASTM C 423 Humidity Resistance -Permanent ambient RH up to 95% at 30*C
without sagging, warping and delaminating ( 13964:2014). Fire Safety - Tested and classified
as non combustible according to EN ISO 1182 with reaction to fire classification class A2 s1
d0 according to EN 13501-1 - European Standard. Light Reflectance - 83% light reflectance.
Indoor Health & Well-being - Complying with the French regulation on VOC emissions, A+
level. Certified by the Finnish Building Information Group (RTS) with the M1 label. Free from
107 N.S. substances ofvery high Concern (SVHC) above 100 ppm as defined by the European REACH 543.23 Sqm 1946.00 - 10,57,125.95 10,57,125.95
regulation(No1907/2006).Product Certified under GRIHA council of India for Green Ratings.
Environmental Product declaration (EPD) acc to international ISO 14025 & EN 15804 series
Circularity - Re-cycled content of more than 70%
CE marking - CE-marked according to the harmonised standard EN 13964:2014
Maintenance - Weekly dusting and vacuum cleaning. Framing system - Providing and fixing
Gypsteel pre coated (Exposed portion only) GI T Grid system in 1200/600x600mm module.
Dimensions:- Main Runner ‘T’ section of size 14x32x0.3mm hot dipped galvanized steel body
and capped with precoated of dipped galvanized steel and 3.0 meter long. Cross Runner ‘T’
section of size 14x32mm hot dipped galvanized steel body and capped with precoated of
dipped galvanized steel and 1.2/0.6 meter long.
Perimeter wall angle of hot dipped galvanized steel angle body of size 19x19mm and 3.0 meter
Digitally signed by ANUJ
Signature of Bidder Page 23 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
P/F ceiling Tile of Shapes/Sizes Square 1200x1200 mm; Rectangle 2400x1200 & 1800x1200
mm; Circle Dia. 1200 & 800 mm; Hexagon 1200x1040 mm with 40 mm thickness, Tiles are
demountable, Panel is manufactured from high density glass wool with Akutex FT surface on
both the sides. Edges are straight cut & painted.
Manufacturing- Manufactured in Sweden, production unit is ISO 14001 certified.
Sound Absorption (alpha w) – 1.0
Humidity Resistance -Permanent ambient RH upto 95% at 30 * C without sagging , warping or
delaminating (EN 13964:2014).
Fire Safety -Tested and classified as non combustible according to EN ISO 1182 with reaction
to fire classification class A2 s1 d0 according to EN 13501 -1
Light Reflectance - 85% light reflectance
Indoor Health & Well-being - Complying with the French regulation on VOC emissions, A+
level. Certified by the Finnish Building Information Group (RTS) with the M1 label. Free from
Substances of Very High Concern (SVHC) above 100 ppm as defined by the European
REACH regulation (No1907/2006). Product Certified under GRIHA Council of India for
Green ratings. Environmental Product declaration (EPD) acc to international ISO 14025 & EN
15804 series of standards.
Circularity - Re-cycled content of more than 70%
CE marking - CE-marked according to the harmonised standard EN 13964:2014 Maintenance -
Daily dusting & vacuum cleaning, weekly wet cleaning
Providing & Fixing Wall Paneling size of 1200 x 2700 mm thickness 40 mm natural square
edge. Size of wall panel should be customizable as per the drawings. Tiles are manufactured
from high density glass wool, demountable panels (with standard fabric approved by the
architect) & wrapped around in concealed system with grippers
Acoustics-Sound absorption(Alpha W) - 1 at minimum 50 mm overall depth of system as per
EN ISO 354 Acoustics-Sound absorption Class - Class A at 50 mm overall depth of system as
per EN ISO 11654
NRC – Minimum 0.9 at 50 mm overall depth of system Articulation Class - 230 as per ASTM
E1111, ASTM E1110
Humidity Resistance -Permanent ambient RH upto 95% at 30 * C without sagging , warping or
delaminating (EN 13964:2014).
Fire Safety- Tested and classified as non combustible according to EN ISO 1182 with reaction
to fire classification class A2 s1 d0 according to EN 13501 -1
-European Standard.
Indoor Health & Well-being - Complying with the French regulation on VOC emissions, A+
level.Certified by the Finnish Building Information Group (RTS) with the M1 label. Free
fromsubstances of very high concern (SVHC) above 100 ppm as defined by the European
REACH regulation (No1907/2006). Product Certified under GRIHA Council of India for
Green ratings. Environmental Product declaration (EPD) acc to international ISO 14025 & EN
15804 series of standards.
Circularity - Re-cycled content of more than 70% CE marking - CE-marked according to the
harmonised standard EN 13964:2014
Maintenance - Daily dusting & vacuum cleaning, weekly wet cleaning
Fabric – Fire Retardant Fabric to be applied on the wall panel as approved by architect. Base
fabric considered @ Rs. 700/RMT.
Digitally signed by ANUJ
Signature of Bidder Page 24 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing & Fixing of GI Open Cell Laying ceiling tile of size 600mm x 600mm and cell size
of 100mm x 100mm with 60 microns powder coating of polyster paint of dimension 15mm
wide, 38mm height and 0.3mm thick."T" runner with suitably spaced joints to get required
length and of size 15x32mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm
centre to centre and cross "T" of size 15x32 mm made of 0.30 mm thick (minimum) sheet,
1200 mm long spaced between main "T" at 600mm centre to centre to form a grid of 1200 x
600 mm and secondary cross "T" of length 600 mm and size 15x32 mm made of 0.30 mm thick
(minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of
110 N.S. 600x600 mm and wall angle of size 22x22x0.4mm and laying false ceiling tiles of approved 300.61 Sqm 3148.00 - 9,46,319.26 9,46,319.26
texture in the grid including, required cutting/making, opening for services like diffusers,
grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from
ceiling using GI slotted cleats of size 30 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and
50mm long dash fasteners, 4mm GI adjustable rod with galvanized butterfly level clips of size
85x30x0.8mm spaced at 1200 mm center to center along main T, bottom exposed width of 24
mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as
per specifications, drawings and as directed by Engineer- in-charge. (supply & Installation of
Providing & Fixing of Aluminium clipin metal ceiling system consisiting of 300 x 1200mm
clipin tile of 60 microns powder coated Aluminium in 0.7mm thickness with beveled edge in
white colour with standard perforataion of 1.8mm dia. The back of the tile should have black
accoustical fleece. The NRC should be 0.70 and suitable for green building application,
Installation: to comprise 3000mm long C' channels spaced at 1200mm centre securely fixed to
the structural soffit by support clamp and approved hangers. The last hanger at the end of each
C channel should not be greater than 600mm from the adjacent wall. Use a C channel
connector for splicing two pcs of C Channel. Ceiling Profile of GI Clip in Metal Ceiling
System of 300x1200 mm module which includes providing and fixing wall angle of size 20x20
111 N.S mm made of 0.4 mm thick pre painted steel along the perimeter of the room with help of nylon 2172.92 Sqm 2603.00 - 56,56,112.74 56,56,112.74
sleeves and wooden screws at 300 mm centre to centre, suspending the main C carrier of size
10x50x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat
37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier
bracket at 1200 mm c/c. Clip in profile main runner having height of 40 mm and width of 19
mm made of GI steel 0.5 mm thick is then fixed to the main C carrier and in direction
perpendicular to it at 600 mm centres with help of suspension brackets & with L profile size of
24x24x0.40mm. Wherever the main C carrier and Clip in Profile have to join, C carrier and
Clip in Profile connectors have to be used, fixing with clip in tiles into Clip in Profile. (supply
& Installation of material)
Digitally signed by ANUJ
Signature of Bidder Page 25 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply and fixing of Linear Baffle Ceiling & Wall System:Vertical & horizontal baffle system,
exhibiting space-delineating characteristics as well as acoustic feature (Optional). The system
comprises baffles 50mm wide & 100mm Deep, installed at 100mm C/C distance. The carrier
rails run perpendicular to the baffles. Individual baffle lengths between 600 and 2400 mm can
be selected. Baffle ceiling are supplied with the end cap matching the similar finish of baffle.
Tolerances according to TAIM, DIN EN 13964 and quality controlled to ISO 9001:2015
approved by SIS. Substructure for durlum POLYLAM® Vertical baffle system consisting of U
shaped galvanized slotted carriers minimum 1.2mm Thick installed perpendicularly to baffles at
maximum 1200mm centres using cross connectors. The primary profiles must be connected to
one another with longitudinal splice connectors. The entire ceiling module shall be suspended
with 6mm diameter galvanized steel threaded rods from the true ceiling officially approved
anchor fasteners maximum at 1200mm Centres as per the requirements of DIN EN 13964 and
112 the statics of the system. Customised wall brackets for wall baffles. Ensure horizontal and flush 89.99 Sqm 11025.00 - 9,92,112.19 9,92,112.19
alignment during installation.
Baffle width: 50mm Baffle height: 100mm Individual baffle lengths: Min.600/Max.2400mm
Module: 100mm C/C. Material: Folded GMS .Minimum 0.50mm Thickness
Surface: Digitally printed woodgrain finish. Manufacturer shall have the fully automatic
powder coating system with power and free conveyorize 3mtr/minute capacity. Powder coating
plant shall be equipped with latest modern technology with fully automatic inline Pre-treatment
using nano technology, Inline automatic water Drying system after pretreatment. Finishes of
ceiling planks shall be powder coated base of minimum 60 microns coating thickness. No Pre-
Coated products shall be accepted. The spacing of the grid angles is according to the
requirements of DIN 18168 and DIN EN 13964 and quality controlled to ISO 9001:2015
approved by SIS & LEED certification by Indian Green Building council
Providing and fixing Stain finished Stainless Steel tower bolts Round (barrel type) with
necessary screws etc. complete :
Providing and fixing Stain finished Stainless Steel with Rubber hanging type floor door stopper
with necessary screws, etc. complete.
Extra for providing 5x3 mm Groove to 25 mm thick
Kota & Granite stone staircase Traed etc.
Providing and fixing Stain finished Stainless Steel 316 glass door Floor Lock with screws etc.
Providing and fixing Combi. finished Stainless Steel 316 glass door pull handles 450x25mm
(pair of handle) dia with screws etc. complete :
Supply & fixing Fresh Color Restroom(Toilet) Cubicle made out of Thickness of Compact
Laminate : 18 mm. Size of Cubicle : 1000mm (W) X 1550mm (D) X 2100mm (H),Door Size :
1995mm (H) x 610mm (W),Overall Height of Cubicle : 2100 mm (Including bottom Gap of
100mm) all Including Stainless Steel - 304 Grade accessories,Occupancy Indicator , Rubber
Lining for Groove. all complete as per direction of Engineer-in-charge. (using series floor
Digitally signed by ANUJ
Signature of Bidder Page 26 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Acoustical Door Specification: P/F acoustical doors for the Auditorium. The door to be
fabricated with 12 mm thick marine grade ply and finished with 3-4mm thk veneer (finish with
melamine polish of approved make shade and color and design both side. The door will have
insulation with one layer of 50mm th. 48 kg. Cu. M density fiberglass/rockwool with 8 mm
HDCF Panel having density 1250 kg/m3 . The fiberglass should be supported with wooden
batten of Kail wood frame work minimum 610mm X 610mm to avoid sagging. The door leaf
will be fabricated using 100mm x 74mm th. Teakwood frame. The fixed door frame
(Chowkhat) shall be 2nd class Teakwood of size 125mm x 79mm, the door frame shall be
provided on all four sides. The door will have hydraulic door closer, cross bar door handle and
relevant hardware for fabrication and fixing. The door seal "D" type of rubber seal to block
noise leakage from gap and acoustic door shutter Magnetic type of to be provided all around of
the door frame as shown in the drawing the door to be attached with the door frame by brass
metal hinges with adequate strength and numbers to avoid sagging. All joints to be sealed with
Dow corning 790 or equivalent mastic sealant. Panic bars to be provided on each leaf of the
doors. (Paid Seprately)The doors on the auditorium side to be finished using non light
reflective media like carpet of dull laminate/ veneer.(TWO HOUR FIRE RATED ACOUSTIC
DOOR WITH VISION PANEL , PANIC BAR & INCLUDING ALL NECESSARY
FIXTURES ETC. )
Manufacture, Supply, and Installation of polycarbonate multi-layered, Multicell Connectible
modular panel system, a complete assembly of coextruded UV protected polycarbonate panels
incorporated into a complete system. Standing seam polycarbonate panel system of minimum
25 mm thick (Min.) with min 1200mm (min.) width. Panels with bigger width will be preferred
for reducing number of joints in the roof.
Panels shall be with grip lock double tooth locking mechanism with interlocking connectible
connectors running lengthwise at both sides of the panel. Panels shall be fixed on Purlins of MS
structure (will be paid Separately) with 3 numbers of self-drilling screws and specials
Trapezoidal Heavy Duty Fastener to ensure a pull-out load of min. 7000N (7KN) tested as per
ISO 6892:1998 and IS 1608: 2005. Panels shall be solo opaque type in opaque and translucent
clear combination with seven layers for required lux level along with all fixing accessories to
ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels
120 N.S with more layers will be preferred for better insulation and improved shading
coefficient. U value shall not be more than 1.6 Watt/m2K as per EN ISO 1077-2:2018 and
respective third Party test certificate shall be produced before procurement. Panels must satisfy
Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate
sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155.Panels
shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample
exposed to UV for 500 Hours as per ASTM G 155.
Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as
required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming
to the detail technical specifications as per approved architectural drawings. Trained and
factory authorized labour with supervision to complete the entire panel installation as per
and direction of the engineering in charge.
Providing and fixing Roller blinds with pelmet/cover in shade and colour all complete as per
direction of Engineer-in-charge.
Digitally signed by ANUJ
Signature of Bidder Page 27 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply and fixing of V Shaped Half Elliptical Fin fixed louver comprising 165mm deep
manufactured out of 1mm thick corrosion resistance Aluminium Alloy AA3005 and formed
on a high precision CNC PNEUMATIC CONTROLLED AMADA BRAKE PRESS
MACHINE for smooth appearance. The fin profile is mechanically fixed between aluminium
extruded press plate and continuous assembly channel. The nylon end caps shall be provided on
both sides of the fins. The louver fins will be provided in the module of 300mm C/C. The
louver fin skin shall be Polyester Powder Coated RAL finish suitable for exterior applications
with minimum 80 micron coating thickness. Coating thickness shall be minimum 80 µm and
determined by TAIM standards.
No cracking/ flacking/blistering/chalking for minimum period of 5 Years shall be guaranteed.
Humidity Resistance as per ISO & Salt Spray Test shall be as per ASTM shall be provided. The
122 N.S. factory assembled louver fins of 165mm projection as per the length & 70mm width shall be 418.70 Sqm 3279.00 - 13,72,917.30 13,72,917.30
fixed mechanically to the installation frame of Aluminium/MS provided by others in a module
of 300mm C/C in varying length as per the site requirement to a maximum of 4mtrs.
For LEED certification by Indian Green Building
Council(IGBC) and ISO 9001: 2015 Quality Management System Certification from SIS , ISO
14001:2015, ISO 50001:2018, ROHS Certifications shall be provided. No Coil Coated roll
formed Products acceptable.
Additional framing for suspension shall be installed by others subject to system & wind load as
per the required standard. The erected installation frame shall be aligned within the tolerances
of ± span plumb line and level with a non-cumulative tolerance of a maximum of 2 mm. (Note -
Sub-structure will be paid
in separate item.)
Provinding & fixing Teak Wood CP Wood Step
123 N.S. 300X25X2250 mm wooden planking, tongued and grooved in flooring, including all
asscerioies all complete as per direction of engineer in charge
Extra for tile cutting with water jet all complete as per
direction of Engineer -in -charge
Providing and fixing 1.00 mm thick deck sheeting (including shear connectors/ stud of 19mm
dia. & 110mm height) for RCC slabs as per specifications including fixing the same. The
contractor shall take all precautions to prevent any bending in sheeting.(RCC & R/F shall be
paid seperately). Plan area shall be measured for payment. The vendor must be able to supply
2hr fire rating for deck sheet with concrete. The deck sheet must have minimum zinc coating of
275 g/m2 (Plan Area shall be measured for Payment)
Extra for providing & laying self compaction concrete
126 N.S. in Columns, pillars, piers, abutments, stub columns, posts and struts, offset and projection of 134.32 Cum 285.00 - 38,280.06 38,280.06
columns, lift walls & pits, shear walls etc.M40 grade concrete as per above specifications
Providing and fixing High Strength Friction Bolts (M8.8/10.9) of following grades for
connections, as per structural drawing and as instructed by Project Managers. Rate to include
cost of grouting, MS washer fastening screws/bolts, tightening with nuts and check nuts,
providing necessary holes in shearwalls (if Required), etc.,
Digitally signed by ANUJ
Signature of Bidder Page 28 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supplying, fabricating, assembling, hoisting/ erecting and fixing in position at all heights and
with all leads, structural steel E350 (In tubes for column, struts, beams, etc.,) all as per
structural drawings and as per detailed specifications (for materials & workmanship) in the
situations described hereinafter including:
The tubes shall be allowed to be made of two rolled sections with maximum 2 side butt
weld i.e. tube made of two C shaped sections. The C sections should be completely rolled
or bent from plates. For smaller tubes, single size butt weld or completely rolled section is
preferred i.e tube made of one open box section which is closed by welding at one corner
only. Other sections like plates, angles, channels can be rolled/fabricated as per structural
drawings and as per detailed specifications (for materials & workmanship) in the
situations described hereinafter
i) Cutting of components to required lengths/ widths and shapes/ profiles.
ii) Smooth grinding/ machining of edges/ faces/ all welding joints.
iii) Preparing the surface to ensure complete removal of mill scale by grit & sand blasting to
achieve finish to grade SA 2.5.
iv) Necessary welding (electric arc welding) for required weld lengths and sizes.
v) Allow for surface preparation, derusting primer coat, three or more coats of synthetic
enamel paint etc. complete all as directed by the Owner.
vi) Providing & Fixing with Anchor Fastener of approved make & size as per drawing &
design wherever required by Project Manager.
Note: The contractor shall submit fabrication drawings for work involved based on
construction drawings (that may be issued during construction period) for approval by the
Owner. The fabrication work shall start only after approval of the fabrication drawings. Any
change required in the fabrication drawings shall be carried out at no extra cost.
128.1 Fabrication shall be in a perfect Architectural workmanship manner and as provided in Section 459000.00 Kg 154.00 - 7,06,86,000.00 7,06,86,000.00
Welding shall be carried out by qualified welders. Electrodes for welding, the procedure,
selection, test and inspection shall confirm to provisions in IS 816, IS 818, IS 822, & IS 833.
Erection/ hoisting shall commence only after passing of fabricated parts by the Owner.
O SUBHEAD-15 (ROAD WORK)
129 16.3 Supplying and stacking at site.
129.1 16.3.4 Over burnt (Jhama) brick aggregate 120 mm to 40 mm 183.72 Cum 974.25 1,78,989.21 - 1,78,989.21
Laying water bound macadam sub-base with brick aggregate and binding material, earth etc.
130 16.5 including screening, sorting and spreading to template and consolidation with light power road-
roller etc. complete.(payment for brick aggregate and moorum etc. to be made separately)
130.1 16.5.1 Over burnt (Jhama) brick aggregate 120 mm to 40 mm 183.72 Cum 725.60 1,33,307.23 - 1,33,307.23
Supplying, stacking and Spreading 6 mm thick red bajri, watering and rolling complete
including preparation of the surface and rolling.
131.1 16.6.1 With road roller/ hand roller 1837.20 Sqm 21.80 40,050.96 - 40,050.96
Digitally signed by ANUJ
Signature of Bidder Page 29 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and laying design mix cement concrete of M- 30 grade, in roads/ taxi tracks/
runways, using cement content as per design mix, using coarse sand and graded stone
aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design
criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading
and compacting mechanically by using needle and surface vibrators, levelling to required slope/
camber, finishing with required texture, including steel form work with sturdy M.S. channel
sections, curing, making provision for contraction/expansion, construction & longitudinal joints
(10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with
approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of
joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).
Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per
design mix is payable/ recoverable separately.
Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to
site in transit mixer
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement
concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarse sand) including making joints with or without grooves (thickness of joints
133 16.69 except at sharp curve shall not to more than 5mm), including making drainage opening 15.90 Cum 8,613.55 1,36,972.76 - 1,36,972.76
wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb
edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to
0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with
water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in
sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10
tonne capacity to achievethe desired density, complete as per specifications and directions of
Engineer-in-Charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path,
park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/
shape, made by table vibratory method using PU mould, laid in required colour & pattern over
50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter
locking paver blocks into the sand bedding layer through vibratory compaction by using plate
vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern,
finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction
of Engineer- in-Charge.
60mm thick Cement concrete paver block of M-35 grade with approved colour, design &
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top,
for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand)
with joints 10mm wide filled with same mortar including ruled pointing etc.
complete as per direction of engineer-in-charge.
P SUBHEAD-16 (PLUMBING WORKS)
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan)
with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever required :
Digitally signed by ANUJ
Signature of Bidder Page 30 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
137.1 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid 39 Each 5,540.55 2,16,081.45 - 2,16,081.45
Providing & fixing White colour vitreous china top counter Oval Wash Basin (Size 550
138 N.S. x 400 mm) with CP brass waste assembly complete including CI / MS brackets duly
painted, cutting and making good the walls floors wherever required.
17.11 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain
with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass
unions complete, including painting of fittings and brackets, cutting and making good the wall
wherever required :
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and
as per the direction of Engineer-in-charge.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm
with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe,
141 17.5 spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap
with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting
and making good the walls and floors wherever required :
141.1 17.5.2 Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern 29 Each 15,115.40 4,38,346.60 - 4,38,346.60
Providing and fixing 75 mm high, 50 mm deep and 18 mm thick stone slab table rubbed, edges
rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with
142 8.1 chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction
of Engineer-in-charge and finished smooth.
142.1 8.10.2 Granite Stone of approved shade 29 sqm 3,542.85 1,02,742.65 - 1,02,742.65
Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved
143 17.31 quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. 33 Each 1,411.15 46,567.95 - 46,567.95
brass screws and washers complete.
Providing and fixing 450mm long braided hose with two 15mm nuts and rubber washers.
15 mm dia nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved
quality conforming to IS:8931
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S.
146 17.16A triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - 39 Each 299.35 11,674.65 - 11,674.65
Providing and fixing C.P. brass bib cock with wall flange of approved quality
conforming to IS standards.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112
148 17.71 mm distance from wall of standard shape with bracket of the same materials with snap 33 Each 146.30 4,827.90 - 4,827.90
fittings of approved quality and colour, weighing not less than 105 gms.
149 17.34 Providing and fixing toilet paper holder.
18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm,
height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
Providing and fixing of WB 46 x 36 with one pair mounting brackets, EWC & Cistern
151 N.S. complete with fittings & seat cover, one no. hinged rail 76 cm & 4 nos. 4 Each 28,302.00 - 1,13,208.00 1,13,208.00
of grab rails 60 cm.
Digitally signed by ANUJ
Signature of Bidder Page 31 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, Installation, Testing and commissioning of wall hanging drinking online water cooler
(Including RO) with bottle filler facility, made by stainless steel top and heavy duty galvanized
steel frame. With cooling capacity, ADA Compliant, size 472 mm Depth X 447mm width,
flexible bubbler guard , operated between 50 to 120 PSI, Chiller unit Suitable to R134a
Refrigerant, Adjustable thermostat control, suitable for 220-230v/50-60 hz A/C Supply
152 N.S. Complete with all accessories which include MD-CU29, which is an EPA registered 4 Each 1,52,143.00 - 6,08,572.00 6,08,572.00
antimicrobial copper that fights off microorganisms which include MRSA and e-coli. The
water Fountain shall possess NSF-USA, GRIHA, TUV, and to be placed at different
location of building. Agency has to execute all civil work for installing the Water
Fountain/Online water cooler for proper functioning and aesthetic view as directed by the
engineer-in-charge without any extra cost. with 150 ltr Storage capacity.
Providing, fixing and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592
including all fittings such as bends, clamps, tees, cowls, clean out plugs, offsets, Y-tees,
tees, door fittings, clips, clamps, stays etc. conforming to IS-14735, including jointing with
rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps
& hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the
same after pipe have been duly laid and testing complete in all respects.
Providing and fixing in position uPVC SWR floor trap conforming to IS:13592
including providing necessary steel support and as per Specification. Making proper connection
154 cutting chase / hole in floors / slabs and bringing the same in proper condition and
shape after placing the trap in right position complete as required. The hopper and
trap shall be set in cement concrete mix 1:2:4 complete as required.
Providing & fixing PVC EXTENSION PIECE for 100 mm dia floor trap formed out of main
155 N.S. pipe(Type A) with multiple side inlets, suitable for various dia pipes, side connections, 55 Each 1,476.00 - 81,180.00 81,180.00
including all fixtures and fittings as per site conditions and as per standard
Providing and fixing Heavy Class SS grating with Cockroach proof SS strainer of approved
156 N.S. design including setting in floor with cement motor to match with floor finish as per architect 55 Each 1,146.00 - 63,030.00 63,030.00
requirement suitable for waster and FT. Size 100 mm X 100 mm
Providing and fixing Heavy Class SS grating with of approved design including setting in
floor with cement motor to match with floor finish as per architect requirement .
Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working
pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees,
tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket
fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc.
including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe
have been duly laid and testing complete in all respects.
Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985
(working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls,
159 N.S. clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps &
hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the
same after pipe have been duly laid and testing complete in all respects.
Digitally signed by ANUJ
Signature of Bidder Page 32 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
(I) Single socketed pipes
Providing & fixing P.V.C. WC connector (straight or bend type) with rubber lip ring.
160 N.S. Including 110 mm dia PVC pipe / bend of required length and proper connection with M 39 Metre 295.00 - 11,505.00 11,505.00
seal to C.I. pipe complete as required.
Providing and fixing clean out plug comprising of GI socket caulked to pipe and cast
brass plug with suitable inlet key for opening male threaded joint with GI class 'C' pipe &
socket. Including lead caulked to UPVC pipes complete as
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1
m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a
coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing UPVC floor drain including all fitting and accessories fixed in cement
mortar complete in all respect.
N.S Providing, fixing, testing and commissioning of UPVC inlet fittings with maximum
164 3 inlets 40, 50 & 63 mm OD size UPVC sockets, fixed to UPVC traps including solvent 84 Each 1,357.00 - 1,13,988.00 1,13,988.00
joint/rubber ring joint complete with all civil work.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c
fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings
with one step CPVC solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in Charge. Concealed
work, including cutting chases and making good the walls
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
166 18.7 including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and testing of joints complete as per direction
of Engineer in Charge.
Internal work - Exposed on wall
167 N.S. Providing and fixing motorized valve of approved quality complete in all respect.
Providing & fixing full way lever operated forged brass ball valve of brass body with
168 N.S. forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with
threaded / flanged joints complete with nuts, bolts,gaskets, washers etc.
Digitally signed by ANUJ
Signature of Bidder Page 33 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and fixing Butter fly valve with nitrile seat and stainless steel stem with lever
operation and cast iron body in powder coated finish, suitable for test pressure of
10Kg/sq.mm) with flanges, gaskets and necessary pad locking arrangement complete
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making
good the walls etc.
Internal work - Exposed on wall
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready
mixed priming coat, both of approved quality for new work :
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto
172 2.10 1.5 m, including getting out the excavated soil, and then returning the soil as required, in
layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
172.1 2.10.1 All kinds of soil
172.1.1 2.10.1.2 Pipes, cables etc. exceeding 80mm dia. But not exceeding 300mm dia. 473 Metre 417.35 1,97,406.55 - 1,97,406.55
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of
173 19.1 cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of
joints etc. complete :
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
174 19.2 stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per
standard design :
Digitally signed by ANUJ
Signature of Bidder Page 34 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and fixing square-mouth S.W. gully trap grade ‘A’' complete with C.I. grating, brick
masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the
weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard
175.1 19.4.1 100x100 mm size P type
175.1.1 19.4.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 6 Each 2,453.55 14,721.30 - 14,721.30
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars
176 19.6 jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine
sand) including testing of joints etc. complete.
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement
177 19.27 mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating
with frame complete as per standard design :
177.1 19.27.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 8 Each 5,589.45 44,715.60 - 44,715.60
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
178 19.3 stone aggregate 40 mm nominal size) up to haunches of S.W./ R.C.C pipes including bed
concrete as per standard design
Constructing brick masonry manhole cement mortar 1:4 (1 cement: 4 coarse sand) R.C.C.
top slab with 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal
size), foundation concrete 1:4:8 mix (1cement: 4 coarse sand: 8 graded stone aggregate 40
mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3
coarse sand) finished with floating coat of neat cement and making necessary
channels in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate
20mm nominal size) finished with a floating coat of neat cement complete as per
standard design.
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm
179.1 19.7.1 internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover
23 kg and weight of frame 15 kg) :
179.1.1 19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 10 Each 11,687.10 1,16,871.00 - 1,16,871.00
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty)
180 19.7.2 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of
cover 58 kg and weight of frame 58 kg) :
With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
181 19.8 Extra depth for manholes
181.1.1 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 4 Metre 8,127.45 32,509.80 - 32,509.80
182.1 19.8.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 4 Metre 9,744.25 38,977.00 - 38,977.00
Digitally signed by ANUJ
Signature of Bidder Page 35 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum
cross section as 23 mm x 25 mm and over all minimum length
263 mm and width as 165 mm with minimum 112 mm space between protruded
legs having 2 mm tread on top surface by ribbing or chequering besides necessary and
183 19.16 adequate anchoring projections on tail length on 138 mm as per standard drawing and 50 Each 487.10 24,355.00 - 24,355.00
suitable to with stand the bend test and chemical resistance test as per specification
and having manufacture's permanent identification mark to be visible even after fixing,
including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1
cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per
Material & labour for constructing Silt trap of size 1500mm x 3000mm x 2000mm deep
in brick masonry with bricks of class designation 7.5 in cement mortar 1:6 (1 cement: 6
coarse sand) including necessary excavation and foundation concrete 150mm thick in 1:3:6
(1 cement : 3 coarse sand : 6 graded stone aggregate of 40mm nominal size), inside plaster
184 N.S. 12mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating 1 Each 2,77,398.00 - 2,77,398.00 2,77,398.00
coat of neat cement, C.C. floor, RCC slab in mix 1:2:4 & RCC baffle wall including
reinforcement, centering & shuttering etc. and SFRC manhole cover and frame 610 x 455
mm heavy duty HD 10 conforming to IS: 12592 complete in all respects as shown on
Material and labour for Constructing Brick masonry percolation pit 3m dia and 5m deep with
bricks of class designation 7.5 in cement mortar 1:6, base concrete 1:3:6 below the brick
wall, including cost of necessary excavation in any type of soil, back filling as required in
20cm thick layers, dewatering if any, shuttering and shoring and disposal of surplus
excavated material within the plot. 2 nos. 300mm dia borings to a depth of 50 metre (to be
measured from the bottom of the percolation pit), provisioning and fixing 160 O.D. PVC pipes,
tested to 6kg/sqcm, in each bore and upto the height of 300mm above the RCC top
slab. The PVC pipe shall be slotted except 3.0 metres at the top and
3.0 metres below from the bottom of the percolation pit, which shall be blind. Top of the
PVC pipe shall be covered with PVC Socket & plug. Each bore around the PVC pipe
shall be filled with pea gravels. The percolation pit shall be filled with river stone/pebbles as
shown in drawings.
The top slab shall be 150mm thick with RCC (1:2:4) including nominal
reinforcement and 2 nos. heavy duty 560 dia SFRC manhole covers with frames as per
IS:12592 (weight not less than 182 kg) shall be provided in the top slab. PVC encased
185.1 12mm dia steel bar Footrests shall be provided 300 centre to centre. The above shall be 1 Each 4,42,657.00 - 4,42,657.00 4,42,657.00
provided all as specified and shown on drawings. 300mm dia RCC pipe for inlet and
overflow as shown on drawings
shall be measured separately.
Making connection of drain or sewer line with existing manhole including breaking into
and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand
186 19.21 : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with
cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat
cement and making necessary channels for the drain etc. complete :
Digitally signed by ANUJ
Signature of Bidder Page 36 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out
187 2.10 the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in
depth, including consolidating each deposited layer by ramming, watering, etc. and disposing
of surplus excavated soil as directed, within a lead of 50 m :
187.1 2.10.1 All kinds of soil
187.1.1 2.10.1.1 Pipes, cables etc, not exceeding 80 mm dia. 200 Metre 255.55 51,110.00 - 51,110.00
188 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
18.4 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1
cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with
hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
190 18.32 aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1
cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of
neat cement complete as per standard design :
190.1 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 2 Each 1,712.15 3,424.30 - 3,424.30
Providing and filling sand of grading zone V or coarser grade alround the G.I.
pipes in external work.
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested
192 18.60 by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required
will be paid separately) :
Making connection of G.I. distribution branch with G.I. main of following sizes by providing
193 18.13 and fixing tee, including cutting and threading the pipe etc.
Digitally signed by ANUJ
Signature of Bidder Page 37 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Design fabricate, deliver (to job site) and install side hung openable aluminium window system
with top and bottom fixed units as per the architectural view. Framing members shall bew 6060
T66 or 6063 16. Aluminium brackets to be 6061-T6 or approved equivalent. The vertical
member should not deflect more than L/175 or 19 mm. whichever is the least for a wind load
(to be calculated as per IS 875 Part 3). The horizontal member should not deflect more than 3
mm. due to dead load and 15 mm. due to wind load of (to be calculated as per IS 875: Part 3).
The system should accommodate DGU as specified in vision areas (refer glazing specification
mentioned as a seperate BOQ item). The basic depth shall be 48 mm., with a vent frame view
width of 19 mm. All gaskets to be EPDM. A secondary window system should also be provided
to holds an openable mesh shutter. The mesh should be of SS 304/316 grade. All exposed
profiles should be powder coated to a minimum of 60 microns. All anchor fasteners to be made
of SS 304 grade. All shims to be capable of transferring the load evenly and made of a suitable
material (GI, Teflon etc.). Capable of lasting the life span of the system. All miscellaneous
items such as peripherals, sealants, backer rods, flashing, fasteners, brackets etc. to be included
in the rate. Performance requirements - 1. The system should have been tested by an
independent internationally accredited third party testing laboratory. 2. The system should
comply to Air infiltration requirement of +/-600Pa when tested in accordance with EN 12207.
3. The system should comply to static water penetration of 600 Pa, when tested in accordance
with EN 1027/ EN 12208. 4. The system should be designed to meet a design wind load of 2.4
kPa and a proof load of 1.5 times the design load. 5. The system should be capable of passing a
repeat air infiltration of +/- 600 Pa. Static water of 600 Pa after wind load test for design load
(to be calculated as per IS 875 Part 3). System and typology detailing: 1. Architectural: The
side-hung windows will have two openable vents to the top and a fixed light at the bottom. 2.
Hardware: All hardware to be procured by system manufacturer to ensure performance. #.
Hardwares include but not limited to hinges, Opening limiters / limiting stays, Engagement
blocks, Locking bars and keeps.
Design Fabricate, deliver (to job site) and install Fixed aluminium system window. The system
to be pressure equalised, ventilated and drained. The outer frame and vent frame should be
made of Aluminium Alloy 6063 T6 with a depth of 40mm. The vertical member should not
deflect more than L/175 or 19mm whichever is the least for a wind load(to be calculated as per
IS 875 part 3). The horozontal member should not deflect more than 3mm due to dead load and
15mm due to wind load(to be calculated as per IS 875 Part 3). The system should accommodate
24mm DGU (6mm Toughened glass+ 12mm Air Space+ 6mm Heat strengthened galss)) in
vision areas (refer glazing specification mentined as a separate BOQ item). All gaskets to be
EPDM. All exposed profiles should be powder coated to a minimum of 60 microns. All anchor
fasteners to be made of SS 304 grade. All shims to be capable of transferring the load evenly
195 NS and made of a suitable material (GI, Teflon etc.) capable of lasting the life span of the system. 3.46 sqm 25,349.56 - 87,709.48 87,709.48
System should be able accommodate surface applied decorative Georgian bars fixing. All
miscellaneous such as peripherals sealants, backer rods, flashing, fasteners, brackets etc. to be
included in the rate. Performance requirements - 1. The system should have been tested by an
independent internationally accredited third party testing laboratory. 2. The system should
comply to Air infiltration requirement of +/-600Pa when tested in accordance with EN 12207.
3. The system should comply to static water penetration of 600 Pa, when tested in accordance
with EN 1027/ EN 12208. 4. The sysytem should be designed to meet a design windload of 2.4
kPa and a proofload of 1.5 times the design load. 5. The sysytem should be capable of passing a
repeat air infiltration of +/-600 Pa. Static water of 600 Pa after windload test for design load (to
be calculated as per IS 875 Part 3).
Digitally signed by ANUJ
Signature of Bidder Page 38 of 90 GULIA Signature of NBCC
BILL OF QUANTITIES (CIVIL WORKS & PLUMBING WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and
repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as
to make it leak proof.
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS :
10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112
mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering
197 19.16 besides necessary and adequate anchoring projections on tail length on 138 mm as per standard 8.00 Each 487.10 3,896.80 - 3,896.80
drawing and suitable to with stand the bend test and chemical resistance test as per
specifications and having manufacture's permanent identification mark to be visible even after
fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement
: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Digitally signed by ANUJ
Signature of Bidder Page 39 of 90 GULIA Signature of NBCC
NBCC (INDIA) LIMITED
(A Govt.of India Navratna CPSE)
NAME OF THE WORK :-CONSTRUCTION OF BALANCE WORKS OF MEHTA FAMILY SCHOOL OF DATA SCIENCE AND ARTIFICIAL
INTELLIGENCE (MFSDSAI) INCLUDING INTERNAL EL, HVAC, FIREFIGHTING, FIRE ALARM, LIFTS, AUDIO VISUAL SYSTEM, CCTV AND
BMS INSTALLATION AND DEVELOPMENT WORKS AT I IT ROORKEE, UTTARAKHAND
NAME OF CLIENT :- IIT ROORKEE
NAME OF THE BIDDER :-
SUMMARY SHEET- ELECTRICAL WORKS
SI. NO DESCRIPTION OF ITEM
DSR N.S.I. Total
1 Conference Room 28 PAX (SUBHEAD-1) ₹ 0.00 ₹ 16,77,516.07 ₹ 16,77,516.07
3 Conference Room 16 PAX (SUBHEAD-3) ₹ 0.00 ₹ 2,63,506.98 ₹ 2,63,506.98
4 BUILDING MANAGEMENT SYSTEM (SUBHEAD-4) ₹ 0.00 ₹ 25,75,747.45 ₹ 25,75,747.45
5 Video Surveillance System(IP CCTV) (SUBHEAD-5) ₹ 0.00 ₹ 29,91,674.54 ₹ 29,91,674.54
Signature of Bidder Page No 40 of 90 DigitallySignature
signed byof ANUJ
NBCC (INDIA) LIMITED
NAME OF THE WORK :-CONSTRUCTION OF BALANCE WORKS OF MEHTA FAMILY SCHOOL OF DATA SCIENCE AND ARTIFICIAL INTELLIGENCE (MFSDSAI) INCLUDING INTERNAL EL, HVAC,
FIREFIGHTING, FIRE ALARM, LIFTS, AUDIO VISUAL SYSTEM, CCTV AND BMS INSTALLATION AND DEVELOPMENT WORKS AT I IT ROORKEE, UTTARAKHAND
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
1 1 Conference Room 28 PAX - SUBHEAD-1
1.1 1.1 Video, Video Switiching and Control
Supply, Installation, testing & Commissioning of 75" android display with SCREEN SIZE 189.3 cm
diagonal, ASPECT RATIO 16:9 3840*216, RESOLUTION (UHD), DISPLAY AREA(H x V)
1649.664(H) × 927.936(V) PIXEL PITCH 0.4296(H) × 0.4296(V), VIEWING ANGLE (HORIZONTAL /
VERTICAL) 178°(H)/178°(V)(Typ.), DISPLAY COLOURS 1.07 G, RF IN 1*Side, AV IN miniAV
1*Side, USB INPUT (2.0 SUPPORT) 2*Side(USB2.0), HDMI INPUT 3*Side, SPDIF OUT YES, RJ-45
1*Side, USB DEVICE SUPPORT USB Supported HDD, SUPPORTED FORMATS PICTURE
FORMAT: GIF/PNG/BMP/JPEG, VIDEO FORMAT: MPEG1/MPEG2/MPEG4/,
H.263/H.264/H.265/MVC/WMV/VC1/VP9/AV1, AUDIO
FORMAT:MPEG1/2/MPEG4/AC3/EAC3/AAC WMA/FLACWMA/FLAC, AUDIO OUTPUT POWER
(RMS) 10 W+10 W(Typ.) etc all complete
Supply, Installation, Testing & Commissioning of table mount flip tops with 2x universal power sockets, 6
pass through holes for HDMI, VGA, audio, LAN etc all complete
1.2 Sound Reinforcement System
Supply Installation testing and commissioning of Full digital Tabletop Delegate Discussion Unit desktop
type pure discussion unit, using a special design to ensure the machine is stable, durable, Heart-shaped
directivity capacitance pickup has double color indicating light, Speaking as red, applying as green, Unit is
1.2.1 NSI a passive device, the power is supplied by system, the input voltage is 24V With howling suppression 14.00 Nos. 49,161.75 - 6,88,264.50 6,88,264.50
function, when microphone is turned on, the native speaker automatically shut down, microphone type
capacitive diapragm, signal noise ratio (S/N) >80dB, headphone output 8-32ohm, 3.5mm miniature socket ,
power of loudspeaker 2W, unit interface 8core aerial line speacial interface etc. all complete.
Supply Installation testing and commissioning of Full digital Tabletop Cairman Discussion Unit with
Priority Chairman unit has the priority function to close all speaking unit ,Capacitive touch buttons, no
buttons pressing sound, long operating life of the buttons, waterproof design, Capacitor heart type direction
microphone, with double color indicator, Power supply; controller power supply, frequency response 20Hz-
20KHz, signal noise ratio >80dB, channel crosstalk >80dB, unit interface 8 core aviation head, maximum
power consumption 1.1W etc. all complete
Supply, Installation, testing & Commissioning of Fully Digital Conference System Controller, Frequency
response 20Hz-20KHz, Signal noise ratio >80dB, Channel crosstalk >80dB, Static power 12W, the static
power consumption <0.05% ,Circular hand-in-hand connection function, Built-in with high performance
CPU, which sets translation, discussion, attendance, voting, electronic plate as a whole, Non compressed
1.2.3 NSI audio transmission, 48K sampling rate, 20Hz~20KHz bandwidth perfect sound, system can open 8 1.00 Nos. 1,83,537.20 - 1,83,537.20 1,83,537.20
microphones at the same time , 31+1 channel cable simultaneous interpretation ,Support PC management
software, TCP/IP control, provide reliable control and safety management, individually adjust line, remote
video conferencing input, 4 audio output interface, the conference unit volume size, the adjusting range is
mute, 40dB to 0dB etc. all complete
Supply, Installation, testing & Commissioning of Ceiling Speaker - 8" / 7.5&15W,
1.2.4 NSI Power(RMS):7.5W/15W, Impedance: 8 ohms , Line Voltage: 70V/100V AC, Frequency Response: 85Hz- 8.00 Nos. 7,746.70 - 61,973.60 61,973.60
17KHz, Sensitivity(1w/1m): 91dB, Speaker unit: 8" (203mm) all complete.
Digitally signed by ANUJ
Signature of Bidder Page 41 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, Installation, testing & Commissioning of mixing Amplifier-250W, Built-in MP3 player and FM
tuner and remote control, MP3 Player with USB,SD port and fluorescent screen to display the sound
number., Four function buttons: previous, play/stop, next and mode, 70V,100V and low impedance 4-16
ohms speaker output, 5 zone and all zone speaker outputs, Three Mic input by phone jack type, AUX 1-3,
Mic 1-3 volume controls and bass/treble tone control, High temp, overload and short-circuit protection etc
1.3 Cables and Connectors
Supply, Installation, testing & Commissioning of 1.5 Sqmm x 2 core(12AWG) ATC copper Conductor,
1.3.1 NSI Insulated Cores,PVC Sheathed Speaker Cables .(as per actual) 100.00 Mtrs 119.18 - 11,918.00 11,918.00
Supply, Installation, testing & Commissioning of conferencing system cables and connectors complete etc
Supply, Installation, testing & Commissioning of Shielded twisted pair CAT6 Cable (STP) complete etc as
1.3.3 NSI required. (as per actual) 20.00 Mtrs 113.12 - 2,262.40 2,262.40
Supply, Installation, testing & Commissioning of 35' High–Speed HDMI Cable with Ethernet, resolution
1.3.5 NSI Supply, Installation, testing & Commissioning of 12U air cooled rack etc all complete . 1.00 Nos 22,644.20 - 22,644.20 22,644.20
Supply, Installation, testing & Commissioning of various cables and connectors including XLR, XLR
femarle, audio, STP, euro block etc all complete
2 2 Seminar Room 90 PAX
2.1 2.1 Video System
Supply, Installation, testing & Commissioning of 3,800 or more ANSI Lumens WXGA LED Projector,
Lamp free, Mercury free, Maintenance free, 2nd generation LED Technology with 30,000 hours lifespan,
Efficient instant power on/of, bright images in any environment, 360° projection and H/V keystone for easy
installation, Comprehensive LAN control for efficient management, Native Resolution: 1280x800, DMD
Type: DC3, Brightness: 3800 (ANSI Lumens), Contrast Ratio: 3000000:1, Display Color: 1.07 Billion
Colors, Light Source Type: LED Light Source Life (hours) with Normal Mode: up to 30000, Lamp Watt:
Optical Zoom: 1.2X, Digital Zoom: 0.8-2.0x, Image Size: 30"-300", Throw Distance: 0.86-10.60m,
(100"@2.95m), Keystone: H:+/-40° , V:+/-40°, Audible Noise (Normal): 31dB, Audible Noise (Eco):
25dB, Input Lag: 16ms, Resolution Support: VGA(640 x 480) to FullHD(1920 x 1080), HDTV
Compatibility: 480i, 480p, 576i, 576p, 720p, 1080i, 1080p, Video Compatibility: NTSC, PAL, SECAM,
Horizontal Frequency: 15K-102KHz, Vertical Scan Rate: 23-120Hz alonwith 120" Diagonal 16:10 Remote
Controlled Motorised Screen, Ceiling Kit & Standard Accessories
Supply, installation, testing and commissioning of 120” diagonal motorised projection screen with remote
control etc all complete..
Supply, Installation, testing & Commissioning of digital podium with the follwoing specifications or better
highly interactive touch monitor., screen type LE, 21" to 22", resolution full HD, aspect ratio 16:9,
brightness 250 nits, computer interface: USB (1), vga (1), HDMI (2), interactive resolution 4000 LPI, tilt
screen, sliding pad for keyboard and mouse, should be non wooden podium, Keyboard and mouse shall
2.1.3 NSI also be part of the solution, podium has number of input/output ports such as HDMI In/Out, VGA In/Out, 1.00 Nos 2,34,784.60 - 2,34,784.60 2,34,784.60
should have auto switcher, Audio In/Out, USBs, Ethernet etc. mount tilt facility, should be floor mount
with wheels, should have gooseneck microphone included, should have sliding provision for keepig laptop
and using touch monitor simultaneously, should be supplied with inbuilt video switcher to automatically
switch between PC or external laptop sources etc all complete..
Digitally signed by ANUJ
Signature of Bidder Page 42 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, installation, testing & commissioning of high resolution camera, integrated with a 20x optical
zoom lens, AAC Audio Encoding Support AAC audio encoding, better sound quality and smaller
bandwidth, Low-light High SNR of CMOS sensor combined with 2D and 3D noise reduction algorithm,
effectively reduce the noise, even under low illumination conditions, picture can still keep clean and clear,
USB3.0 support USB 3.0 ultra-high speed interface, can transfer uncompressed original video, and
downward compatible with USB 2.0 . USB3.0 , HDMI Network can output at the same time. It also
2.1.4 NSI support CVBS interface, 1080p Full HD Apply Panasonic's 1/2.7 inch, 2.07 million effective pixels high 1.00 Nos 1,85,920.80 - 1,85,920.80 1,85,920.80
quality HD CMOS sensor, can reach maximum 1920 x 1080 high resolution and achieve quality image,
20x optical zoom & 32x Digital Zoom, Using high quality TAMRON Lens, Local Storage support local
storage module, directly recording to local USB flash disk without NVR, Ultra-high Frame Rate the output
frame rate up to 60fps in 1080p, Remote Control Using R232 and RS485 interface, all the parameters of
the camera can be controled remotely, H.265 Support Enabling full HD 1080p video stream by ultra-low
bandwidth, bidder to submit bid specific OEM authorization etc all complete .
Supply, installation, testing & commissioning of HDMI extension over catX trasnmitter and receiver pair
upto 40 meters etc all complete.
Supply, installation, testing and commissioning of ceiling mount for PTZ camera as per ceiling design etc
Supply, installation, testing & commissioning of AV bridging device, should support resolutions up to
18Gbps (600MHz) 4K UHD with HDR (via the bypass path) while simultaneously streaming the audio and
video signal at 1080p to a USB connected PC, Shall have video timing stabilization feature helps to ensure
that the USB capture stream won’t lock up or drop, Digital stereo audio from either HDMI (LPCM 2.0) or
the 3.5mm analog audio input will be captured with the HDMI video source and should be selectable
within the capture software., HDMI input and output with HDR, 3D & 4K@60Hz support, DVI 1.0
compatible HDCP 2.2 and, HDCP 1.x compliant Supports up to 4K UHD (18Gbps, 4K@50/60Hz 4:4:4, 8-
bit) video input and output, should supports Deep Color input and output up to 12-bit Supports 10-bit and
12-bit HDR (High Dynamic Range) input/output Supports CEC bypass, Automatically scales 4K sources to
1080p for USB capture Supportsm video timing stabilization to help ensure a reliable and stable USB
capture stream, Capturing over USB 3.0 allows uncompressed video and audio data capture (1080p, LPCM
Supply, installation, testing & commissioning of server with having i7 11th gen, 16GB RAM, 1TB SSD,
Windows 10 pro, Artificial Intelligence Based Performance improvement software goes by default with
Windows OS, and 4GB graphics card, Minimum 4 PCIe slots – 2 PCIe x 1, 1 PCIe x 4 , 1 PCIe x 16,
Power 300W or higher with 92% Power Efficiency,monitor, Keyboard, Mouse should be of the same make
as OEM and have OEM logo/ trademark embossed on them (No sticker), To be supplied with monitor and
keyboard, Bidder to sumbit bid specific OEM authorization etc all complete.
Digitally signed by ANUJ
Signature of Bidder Page 43 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply and commissioning of video conferencing and webinar license, should enable calling with a SIP
devices, suitable licenses should be considered. All of the video and audio should be integrated into the
conference room equipment and calendar systems, Gallery feature should have AI to take a single-camera
view of multiple people in a call, and send up to three unique video streams to better display the in-room
participants to remote attendees. Remote Attendees should get an improved face-to-face experience and
interaction with call participants, it should enable start, stop and control meetings from personal mobile
devices or in-room shared controller, should support Workspace Reservation,should have Digital Signage
to display announcements and live-stream select events across the organization, Upcoming events bulletin
2.1.9 NSI board, should enable scheduling Displays, See room availability and start a meeting with one touch, shoudl 1.00 Nos 1,85,920.80 - 1,85,920.80 1,85,920.80
have Voice Command to Start a meeting without touching the controller, shoudl have centralized
Management - Dashboard to view reporting and analytics for each room available to admins, platform
should give flexibility to the users to join the meeting from PC, laptop, desktop, android and iOS devices.,
Platform must provides a complete collaboration suite for users to create adhoc meetings, schedule
meetings, chat in-meetings / outside meetings and share content in a meeting, Platform should be delivered
from cloud in a secure manner with encryption standard of AES 256 GCM, Platform should be able to
allow cloud native room devices to participate into the meeting , Platform should also allow thrid party
participants to join the meetings from cloud native room devices,
Platform should provide IM&P platform which allows point to point and group chat capability, Host should
be able to add or remove participants from the meetings, lock meetings, invite participants create breakout
rooms, manage waiting rooms , Platform should provide one-to-one and Group chat with file sharing
capabilities. , Platform should have capability for the admins / users to create chat groups / channels,
Platform should have ability to schedule meetings and re-schedule them on demand, The meetings should
be joined from cloud native room devices without need for external gateways. Minimum 200 such
participants should be able to connect to the call, should interoperate with atleast any 5 SIP or H.323
endpoint - Enable SIP or H.323 room systems to communicate with desktop, tablet, mobile devices and
other SIP or H.323 endpoints, should Support in-session webninar chat, Answer and moderate Q&A
throughout the session, Allow attendees to raise hand and respond to polls, Promote attendees to panelists
who can share audio and video, Customize webinar registration page and reminder emails, Promote social
share buttons, Build post-webinar landing page, Brand the live streaming video watermark, Gather attendee
feedback with an automatic post-webinar survey, Report on webinar attendance, Measure audience
engagement, Analyze Q&A as well as results to audience polls and surveys, Easily export all data into a csv
file, Unlimited webinar sessions for up to 30 hours each, Ability to export registrant and attendee lists,
Integrate with CRM and marketing automation tools, Monetize your webinar through paid registration,
Ability to live stream your webinar to third-party platforms, Record your webinar to the cloud, Access to
post-session reporting, Upto 500 participants, license should be for 1 year from date of handover, bidder to
submit bid specific OEM authorization
2.2 Sound Reinforcement System
Supply, Installation, testing & Commissioning of 30Watt wall speaker, Impedance: 8 Ohms, Woofer:
2.2.1 NSI 5.25"(131mm), Tweeter: 0.5" (13mm) Mylar Dome, Sensitivity: 86+-2dB/M/W, Frequency: 70Hz-18KHz(- 12.00 Nos 10,368.66 - 1,24,423.92 1,24,423.92
10dB), Power(RMS): 30Wetc all complete.
Supply, Installation, testing & Commissioning of mixing Amplifier-250W, Built-in MP3 player and FM
tuner and remote control, MP3 Player with USB,SD port and fluorescent screen to display the sound
number., Four function buttons: previous, play/stop, next and mode, 70V,100V and low impedance 4-16
ohms speaker output, 5 zone and all zone speaker outputs, Three Mic input by phone jack type, AUX 1-3,
Mic 1-3 volume controls and bass/treble tone control, High temp, overload and short-circuit protection etc
Digitally signed by ANUJ
Signature of Bidder Page 44 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, Installation, testing & Commissioning of dual microphone system with Receiver: Dual Channel
2.2.3 NSI Non-Diversity, Frequency Response, 50Hz-16KHz, Polar Pattern (Hand mic) Cardioid, Output, Individual 1.00 Nos 27,888.12 - 27,888.12 27,888.12
Channel: XLR, Mix out: ¼" Jack, Power Req. (Hand mic), 2 x 1.5V AA etc all complete.
2.2.4 NSI Supply, Installation, testing & Commissioning of wireless lapel microphone etc all complete. 1.00 Nos 17,877.00 - 17,877.00 17,877.00
Supply, installation, testing & commissioning of 6 input and 4 output digital mixer with automatic echo
cancellation, USB audio output etc all complete.
2.3 Cables and Connectors.
Supply, Installation, testing & Commissioning of 1.5 Sqmm x 2 core(12AWG) ATC copper Conductor,
Insulated Cores,PVC Sheathed Speaker Cables .(as per actual)
Supply, Installation, testing & Commissioning of 22 AWG 2 core ATC Copper Conductor,PVC Insulated,
2.3.2 NSI 90% ATC Copper Braid Shielded, PVC Sheathed Microphone Cable complete etc as required. (as per 20.00 Mtrs 107.06 - 2,141.20 2,141.20
Supply, Installation, testing & Commissioning of Shielded twisted pair CAT6 Cable (STP) complete etc as
required. (as per actual)
Supply, Installation, testing & Commissioning of 35' High–Speed HDMI Cable with Ethernet, resolution
support 4K@60Hz (4:2:0)
Supply, Installation, testing & Commissioning of 3' High–Speed HDMI Cable with Ethernet, resolution
support 4K@60Hz (4:2:0)
Supply, Installation, testing & Commissioning of various cables and connectors including XLR, XLR
femarle, audio, STP, euro block etc all complete
2.3.7 NSI Supply, Installation, testing & Commissioning of 9U air cooled rack etc all complete . 1.00 Nos 17,877.00 - 17,877.00 17,877.00
3 3 Conference Room 16 PAX
3.1 3.1 Vedio System
Supply, Installation, testing & Commissioning of 55" android display with SCREEN SIZE 139 cm
diagonal, ASPECT RATIO 16:9, RESOLUTION UHD(3840*2160), DISPLAY AREA(H x V) 120.96
(H)*68.04 (V) cm, PIXEL PITCH 0.0105 (H)*0.0315 (V) cm, DISPLAY COLOURS 1.07 Billion,
VIEWING ANGLE (HORIZONTAL / VERTICAL) 178 °/178 ° (H/V), RF IN 1*Side, DTV IN 1*Side, AV
IN 1mini *Side, USB INPUT (2.0 SUPPORT), 2*Side(USB2.0), HDMI INPUT 3*Side(HDMI 2.0),
HEADPHONE OUT 1*Side, SPDIF OUT YES,optical, RJ-45 1*Side, USB DEVICE SUPPORT USB
Supported HDD, SUPPORTED FORMATS PICTURE FORMAT:, PNG/BMP/JPEG, VIDEO
FORMAT: H.265 / H.264 / H.263 / MPEG1 / MPEG2 /MPEG4, AUDIO FORMAT: MPEG1 / 2 / MPEG4
/ AC3 / EAC3 / AAC / MP3/WMA/FLAC, HOTEL MODE Yes, Basic, CEC Yes, Basic, SOUND
OUT(ARC) Yes, DOLBY AUDIO/DOLBY MS12 Yes, HDR10/HDR10+/HLG Yes. BLUETOOTH Yes
(Ver. 4) etc all complete
Supply, Installation, Testing & Commissioning of table mount flip tops with 2x universal power sockets, 6
3.1.2 NSI pass through holes for HDMI, VGA, audio, LAN etc all complete 1.00 Nos 22,525.02 - 22,525.02 22,525.02
3.2 Cables and Connections
Supply, Installation, testing & Commissioning of 35' High–Speed HDMI Cable with Ethernet, resolution
support 4K@60Hz (4:2:0) .
4 4 BUILDING MANAGEMENT SYSTEM
4.1 4.1 WORKSTATION
Supply, installation, testing and commissioning of core i7 processor, Memory of 32 GB, Hard disk size (2x
800 GB Professional/Enterprise SSD with SATA or SAS), Giga speed Network card with 2 GB Graphic
card of Resolution 2.560 x 1600 with Onboard Intel 4600 HD Windows 8.1, 64 bit Edition or Windows
Server 2008 R2 and original anti virus software.
4.1.2 NSI Laserjet A4 Black and White printer 1.00 Nos 11,821.04 - 11,821.04 11,821.04
Digitally signed by ANUJ
Signature of Bidder Page 45 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, installation, testing and commissioning of Layer 2 unmanaged switch with 16/24 ports (RJ-45) port
rack mountable, SMPS power supply. The switch to switch distance shall not exceed beyond 80 meters.
4.2 4.2 APPLICATION SOFTWARE
SITC of the following window based graphical software for IBMS system with 1No Client for Operator
workstation. The Software shall have 3D & HD vector dynamic graphics with Autocad import of plan with
Zoom In & Zoom Out facility, Native 64 Bit System , Multi-Monitor Support-( Max 4 Nos) , Multi-
language support , BTL ,UL , EN Certified System, BACnet Profile B-AWS (Advanced workstation) as per
the BTL Listing, dot net platform, Certified OPC DA Server by OPC Foundation, Web-Based Server
software shall permit use of Standard Web-Browsers such as Microsoft Internet Explorer, Netscape
Navigator, etc. The Software shall comply to international standards and strive to deliver products that
4.2.1 NSI meet security standards such as ISA/IEC 62443, UL2900, ISO/IEC 27001, ISO/IEC62443 and OWASP. 1.00 Nos 2,79,938.67 - 2,79,938.67 2,79,938.67
Cybersecurity audit trail , 4-eye principle , Seamless integration of certificates within customer IT
infrastructure, Microsoft’s active directory-based authentication, Use of network infrastructure that
supports physical network or VLAN segmentation, Placing the web server in a “demilitarized zone”
(DMZ), End-to-end encryption, from client to server, End-to-end encryption between servers, Certificate-
based data exchange, Encrypted backups. The software shall have the capability to integrate with Lighting.
The software license shall have 5000 points.
Supply, installation, testing and commissioning of High-quality CAPACTIVE touch 7.0'' panels for
technical on-site operation of plants as well as room operation. The Touch Panel shall have integrated web
4.2.2 NSI server and a BACnet/ IP web interface to connect a HTML5 browser to a device on the network. Generic 1.00 Nos 65,444.97 - 65,444.97 65,444.97
operation and monitoring of plant functions (alarms, schedulers, calendars, set point changes, display of
actual values, etc.)
Supply, installation, testing and commissioning of True IP Based DDC Standalone 32 Bit Intelligent,
inbuilt web browser, peer to peer communication, interoperable DDC as per the specification. The compact
controller shall have inbuilt 2-port Ethernet switch, WLAN interface and Cloud Connectivity. The
controller shall have min 12 inputs/outputs inbuilt and can be expandable upto max 40 points by
Input/Output Modules. The DDC shall have 300 Mhz processor with 128 MByte SDRAM (DDR3) and
512 MByte NAND Flash. The controller shall be freely programmable and have System functions
(alarming, scheduling, trending, access protection with individually definable user profiles and categories).
It should have one integration port inbuilt and port for POT for local interface.
The above shall be housed in vandal proof, lockable & secure MS Cabinets to be supplied along with all
necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for
future expansion.
4.2.3.1 NSI Controller for Common Area 1.00 Set 58,592.12 - 58,592.12 58,592.12
4.2.3.2 NSI Controller for AHU (2 AHU per DDC) 4.00 Set 58,592.12 - 2,34,368.48 2,34,368.48
4.2.3.3 NSI Controller for HRU (2 HRU per DDC) 1.00 Set 58,592.12 - 58,592.12 58,592.12
4.2.3.4 NSI Controller for Axial type Exhaust Fans ( Max 4 Fans per DDC) 4.00 Set 58,592.12 - 2,34,368.48 2,34,368.48
4.2.3.5 NSI Controller for Electrical System LT/HT/Transformer/DG 1.00 Set 2,64,451.33 - 2,64,451.33 2,64,451.33
4.2.3.6 NSI Controller for Lifts (2 Lifts in 1 DDC) 2.00 Set 58,592.12 - 1,17,184.24 1,17,184.24
4.2.3.7 NSI Controller for Fire Fighting system & fire suppression System 1.00 Set 58,592.12 - 58,592.12 58,592.12
Supply, installation, testing and commissioning of True IP Based BTL & UL Listed for third party
integration. The controller shall have 2-port Ethernet switch, WLAN interface and Cloud Connectivity. It
should have BTL label (BACnet communications passed the BTL test) and consisting of Dual
microprocessor with Storage capacity of 1 GByte RAM. It should support Real Time clock upto 7 Days. It
should Support of the major communication protocols: BACnet/IP, BACnet MS/TP, Modbus IP and
Modbus RTU upto 500 points. (Note - Integrator shall be of same DDC make only.)
Integration of VRV on BACnet/IP
Digitally signed by ANUJ
Signature of Bidder Page 46 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Integration of AHU VFD on Modbus over RS485
Integration of UPS on Modbus over RS485
Integration of DG Sets on Modbus over RS485 - 4 Nos
Integration of HT Power Meter on Modbus over RS485
Integration of FAS System on BACnet/IP
4.3 FIELD INSTRUMENTS
Supplying, installing, testing and commissioning of the following sensors / transducers / transmitters.
4.3.1 NSI Combined Ambient air temperature + humidity, CO2 sensors with Display. 1.00 Nos. 26,594.31 - 26,594.31 26,594.31
4.3.2 NSI Combined PM2.5, PM10 Sensor with Display 1.00 Nos. 17,741.66 - 17,741.66 17,741.66
4.3.3 NSI Differential pressure switch Air 16.00 Nos 2,912.84 - 46,605.44 46,605.44
4.3.4 NSI Temprature sensor 1.00 Nos 1,774.57 - 1,774.57 1,774.57
4.3.6 NSI Duct static Pressure sensor 9.00 Nos 10,676.71 - 96,090.39 96,090.39
4.3.9 NSI Flameproof Level Switch 1.00 Nos 18,427.45 - 18,427.45 18,427.45
4.4 Cabling and Conduiting
Supply and laying of 2 Core 1.0 Sqmm Annealed Tinned Copper, Twisted pair, Shielded unarmoured cable
for signal and power as per specifications
3 Core 1.5 Sqmm Annealed Tinned Copper, Twisted pair , Shielded armoured cable for signal and power
as per specifications
4.4.3 NSI Supply and laying of Cat-6 unarmoured cable with required jacks and points 1200.00 Rmt 35.35 - 42,420.00 42,420.00
4.4.4 NSI HOT DIP GALVANISED GALVANISED PERFORATED TYPE CABLE TRAY - - -
5 5 Video Surveillance System(IP CCTV)
Supplying, installation, testing and commissioning of 2 megapixels resolution Network Dome Camera for
true HD quality images,2.8 – 12 mm motorized lens varifocal lens, Quad video streaming, SD card support
upto 256 GB, True Day/Night (TDN) functionality for true color image ,Motion Detection 4 Zones, Multi- Level
Sensitivity Privacy Zones 4 Zones ( 8 Zones), Snapshoot Support JPEG format Password Protection Support
Character Display Support (Channel /Date), IR Illumination20-30M IR( 30 Mtrs illuminators for clear images in
low light conditions Wide Dynamic Range 3D noise reduction for sharper images and lower bandwidth use in
low light ONVIF compliant complete in all respect with NDAA compliant, MTBF upto 1,00,000 Hours@40
degree (Support Document should be provided) with complete accessories as required as per specifications
Digitally signed by ANUJ
Signature of Bidder Page 47 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, installation, testing and commissioning of 2 megapixels resolution Network Bullet camera with
Quad video streaming, Imager 1/2.8”SONY 2.43 mega low illumination CMOS,Video Compression
H.264/MJPEG,Day/Night, Mechanical ICR, Minimum Illumination-0Lux/F1.4(IR ON), IR Illumination-40-50M/30
Mtrs, Electronic Shutter-Auto/Manual(1/25~1/10000), SD card support up 256 GB, Lens 2.8 – 12 mm
Motorized varifocal lens, Resolution Main stream :D1/Q1080P(960*540)/HD720P/ HD1080P 1-25/30fps, Digital
5.1.2 NSI Noise Reduction-3D, Wide Dynamic Range-Digital WDR Motion Detection -4 Zones, Multi level Sensitivity, 22.00 Each 31,248.39 - 6,87,464.58 6,87,464.58
Privacy Zones-4 Zones/8 Zones, Snapshoot-Support JPEG format, Password Protection-Support, Character
Display-Support (Channel /Date). Regulatory Emissions-FCC Part 15 CE: EN55022, Immunity -CE: EN50130-
4, IP Rating- IP66/IP67 & IK10 rated enclosure to protect against dust and water damage ONVIF compliant
with NDAA compliant, MTBF upto 1,00,000 Hours@40 degree (Support Document should be provided) with
complete accessories as required as per specifications
Supplying of 4U Rack mount single chassis Network Video Recorder with dual Gb NIC + HDMI + 1 Display
Port, max 2 simultaneous monitors, RS-232/485 serial port, DVD, Server Operating System - Windows 10 /
Ubuntu Linux 16.04, Gen 4 Intel Core i7, Local Client Display Rate (FPS) Windows – 700 FPS (HD) Linux –
900 FPS (HD), High Performance, High Reliability IP Recorder — Continuously records 400Mbps
(Windows) & 800 Mbps (Linux) of video while hosting a local client, multiple remote clients and the web server
on a single server,RAM-8 GB, 16 GB (Optional)solid-state operating system drive, 6 x USB 2.0, 2x USB 3.0
5.1.3 NSI high air flow cooling and hardware monitoring features ensure maximum uptime. keyboard and mouse, 1.00 Each 3,60,733.62 - 3,60,733.62 3,60,733.62
Professional Grade client and server software pre-installed and software updates. Access live and recorded
video on multiple client PCs with free Windows, Mac or Linux client application. web server application is pre-
installed on the server to access video through a web browser or free Mobile iPhone / iPad and Android apps.
Maximum Storage Capacity 240TB RAID 1/5/10 or 6, Maximum Hard Drive 20 Slot (Up to 12TB) Support Up
to 64 IP Camera with NDAA compliant , with Failover Support(Optional), Dual Redundant Power Supply with
complete accessories as required as per specifications
5.1.4 NSI Supply, installation, testing and commissioning of Enterprise Class 6TB HDD. 10.00 Each 26,561.99 - 2,65,619.90 2,65,619.90
Supply, installation, testing and commissioning of Video Management System (VMS) software shall be
used to view live and recorded video from capture cards and IP devices connected to local and wide area
networks. The VMS software shall have a client/server-based architecture that can be configured as a
standalone VMS system with the client software running on the server hardware and/or the client running on
any network-connected TCP/IP workstation. Multiple client workstations shall be capable of simultaneously
5.1.5 NSI viewing live and/or recorded video from one or more servers. Multiple servers shall also be able to 55.00 Each 6,446.83 - 3,54,575.65 3,54,575.65
simultaneously provide live and/or recorded video to one or more workstations. The VMS server software shall
also have the ability to be installed on an IP edge device—such as an IP camera or encoder that allows for 3rd
party applications—allowing the device to serve as both a server and IP video recording device.The VMS shall
not charge for the number of concurrent clients (min. 50 thick clients and 16 mobile clients to be provided
along with VMS). with complete accessories as required as per specifications
Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor
(8M Cache, up to 3.90 GHz); RAM: 8GB Non-ECC DDR3 1600MHz SDRAM Memory; Keyboard: 12 function
5.1.6 NSI keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; 20" TFT Monitor; Dual Graphics 2.00 Each 99,571.86 - 1,99,143.72 1,99,143.72
Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk:
250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 10 Professional 64 Bit.
Digitally signed by ANUJ
Signature of Bidder Page 48 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supplying, Installation,Testing & Commissioning of 55 " LED Full HD TV Resolution 1920 x 1080
,Contrast Ratio (Typical) 4000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source
Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play
(DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock,
HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-Swith Mounting
Brackets as per Technical Specification complete in all respect.
6 6 ELECTRICAL WORKS
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate,
suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core
cable etc. as required. Group-C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without
independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in
surface/ recessed steel onduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in
6.3 1.5 surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core 9200.00 Metre 267.65 24,62,380.00 - 24,62,380.00
cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface/ recessed steel conduit as required
6.4.3 1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Metre 265.63 - - -
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,
6.6 1.31 including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, 560.00 Each 405.01 2,26,805.60 - 2,26,805.60
connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,
6.7 1.32 including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular 330.00 Each 499.95 1,64,983.50 - 1,64,983.50
switch, connection etc. as required.
1.24.4 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,
6.8 +1.24.3 + including providing and fixing 2 Nos. 3 pin 5/6 amps modular socket outlet and 1 No. 16 amps modular 185.00 Each 693.87 1,28,365.95 - 1,28,365.95
1.27.4 switch, connection etc. as required. ( UPS Points ).
Supplying and fixing 32 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed
plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with
chained metal cover for the socket out let and complete with connections, testing and commissioning etc.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including
1.2 painting in case of surface conduit, or cutting the wall and making good the same in case of recessed
conduit as required. (For ckt wiring extra)
Digitally signed by ANUJ
Signature of Bidder Page 49 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Note;- Only Conduit for DATA,Wiring and Data Outlet in the scope of IIT Roorkee
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.
Supplying and fixing modular type call bell/ buzzer with LED indication, suitable for single phase, 230
volts, complete as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including
1.2 painting in case of surface conduit, or cutting the wall and making good the same in case of recessed
conduit as required. (For Data wiring)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution
2.4 board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB
distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus
bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as
required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.
Supplying and fixing following way, single pole and neutral,
sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required.(But without MCB/RCCB/Isolator)
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current
circuit breaker (RCCB), having a sensitivity current 100mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable
2.1 for inductive load of following poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
6.35 2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 25.00 Nos. 8.08 202.00 - 202.00
Supply, assembly and laying of under floor trunking made out of 1.6mm thick GI sheet complete with
jointing sleeve, horizontal bends, floor junction box, vertical bends, level adjustment components and
closer, vertical elbow, covers, access outlet. etc. complete with all other accessories under floor installation
including cutting and chasing the floor/ or on surface, making good the same, placing in position and
cleaning from inside complete etc. as required.
Digitally signed by ANUJ
Signature of Bidder Page 50 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply Installation, testing and commissioning of following fittings/ luminaires/ ceiling fans complete with
necessary starter/s & copper wound/ electronic ballasts, capacitors, lamps, louvers & all other accessories,
down rods of suitable length, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single
core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core
cable etc. complete as required.
SITC of surface mounted batten, 1200mm (apprx.), IP65 dust and waterproof LED minimum 4100lm,
equivalent to Make: Philips(Signify) model : WT150C LED40S-6500 PSU L120
SITC of Suspended / Recessed pure Slim LED 4 ft stand alone Light Fittng with minimum Lumen 2500
equivalent to make: Phillips (Signify) and Cat No. RC810B LED30S 4000 PSU W10L120 OD WH
SITC of LED Recessed Downlighter with spring clips and minimum lumen 1500 lumens equivalent to
Make: Philips (Signify) model Green Perform Sleek & Cat No. DN296B LED15S-6500 PSU WH
Supply of LED indoor surface Downlighter with minimum lumen output of 1500 lumens equivalent to
make: philips (Signify) model Sleek Surface SM251C LED20S- 6500 PSU WH
Supply of LED panel housing recessed Light Fitting with minimum lumen output of 3500 lumens
6.49 NSI equivalent to Make: Phillips (Signify) Full Glow G6, Cat. No.: RC380B LED36S-6500 G6 L60W60 PSU 301.00 Nos. 4,983.34 - 14,99,985.34 14,99,985.34
SITC of Surface mounted 600mm (apprx.) LED Light Fixture minimum System Lumen Output- 1200 lm
equivalent to Philips (Signify) Cat. No. Signify BN021C LED12S 6500 PSU G
SITC of LED Bulkhead Light housing: vandal resistant, self extinguishing, UV-stabilised anti yellowing
6.51 NSI polycarbonate. Diffuser: vandal resistant, Minimum System Lumen - 735lm, equivalent to Make: Phillips 18.00 Nos. 1,037.27 - 18,670.86 18,670.86
(Signify) Cat. No. WT 140W LED7S NW PSU S1 PC
SITC of Hanging LED Fixture made of die cat alluminium with clear polycarbonate diffuser alongwith
6.52 NSI suitable suspension kit, equivalent to Make: Phillips (Signify) Cat. No. SP 321 LED20S-5700 PSU NB 6.00 Nos. 6,229.68 - 37,378.08 37,378.08
SITC of Spot Light Housing: in die-cast aluminium; Minimum system wattage 27W, Minimum System
Lumen 2100lm, equivalent to Make: Phillips (Signify) Cat. No. Uniflood C Small (27-36W)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all
6.54 1.41 types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 50.00 Nos. 169.68 8,484.00 - 8,484.00
1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Supply, Installation, Testing and Commissioning of 900-1200 mm sweep, BEE 5 star rated, ceiling fan
with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod,
6.55 NSI 2 nos. canopies, shackle kit, safety rope, copper winding, and all remaining accessories including safety 196.00 Nos. 3,933.95 - 7,71,054.20 7,71,054.20
pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega
ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with
Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2
6.56 NSI nos. canopies, shackle kit, safety rope, copper winding, and all remaining accessories including safety pin, 5.00 Nos. 4,176.35 - 20,881.75 20,881.75
nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega
ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch
box including connections but excluding modular plate etc. as required
6.57.1 NSI SITC of wall mounting fan 400 mm sweep revolving type with speed regulator 5.00 Each 2,714.88 - 13,574.40 13,574.40
External Lighting -
Digitally signed by ANUJ
Signature of Bidder Page 51 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
SITC of LED Post Top diecast alluminuim housing, polycarbonate diffuser, impact resistnce and fixture
6.59 NSI protection level IP65/IK10 equivalent to Make: Phillips, Cat No. BGP 161 LED 2500/NW PSU 220-240V 6.00 Nos 20,764.59 - 1,24,587.54 1,24,587.54
SITC of 3.0-4.0 mtr Decorative street GI lighting pole of the following standard shall be used on work
Design& Construction: Decorative steel tubular GI, Pole should be hot dipped galvanised, Pole should be
PU painted (marine grade) with 4 nos of foundation nut & bolt (20mm dia & 600 mm long with templates)
with a base plate of 250mmx250mm, Base Plate thickness- 15 mm. GI Pole Thickness- 3.0mm. Pole shall
have GI coating thickness of 60 micron and paint coating thickness of 90 microns. Pole OD shall be 114
mm dia with inbuilt junction box up to 6.0mtr mtr. Pole shall have a din rail for MCB mounting provision
with Bakelite sheet and 32 mm Electrical Connector with foam sheet Packing. Pole sample and drawings to
be submitted before procurement and pole design shall be approved by EIC.
SITC of LED Bollard Light diecast alluminuim housing, polycarbonate diffuser, impact resistance and
6.61 NSI fixture protection level IP65/IK10 equivalent to Make: Phillips, Cat No. BCP 151 LED 150/NW PSU 220- 6.00 Nos 12,458.35 - 74,750.10 74,750.10
SITC of LED Inground uplighter compact and robust design with diecast alluminuim housing and stainless
6.62 NSI trim, IP68 waterproof connectors equivalent to Make: Phillips Cat No. BBP 341 LED 540/WW 6W 20D 6.00 Nos 7,475.01 - 44,850.06 44,850.06
SITC of Surface Mounted Linear Wallwasher Housing extruded aluminium housing, IP66 / IK06
protection equivalent to Make: Phillips Cat No. UniStrip G4 AC BCP384 20-80W
SITC of LED Inground Linelite compact and robust design with extruded alluminium housing, IP68
6.64 NSI waterproof connectors equivalent to Make: Phillips Cat No. Signify Cat No. BBP412 LED RGB 36W 24V 4.00 Nos. 18,168.89 - 72,675.56 72,675.56
SITC of Architecrural Spot Light Housing: in die-cast aluminium; Minimum system wattage 27W,
6.65 NSI Minimum System Lumen 2100lm, equivalent to Make: Phillips (Signify) Cat. No. Uniflood C Small (27- 12.00 Nos. 45,473.23 - 5,45,678.76 5,45,678.76
SITC of LED step light compact and robust design with diecast alluminuim housing and stainless trim,
frosted glass didffuser, IP67/IK08 waterproof connectors equivalent to Make: Phillips, cat no. BWG150
LED50/WW PSU 220-240V IP67 7043
SITC of LED spike light compact and robust design with diecast alluminuim housing and stainless trim,
6.67 NSI frosted glass didffuser, IP65/IK08 waterproof connectors equivalent to Signify Cat. No. BGP150 8.00 Nos. 4,879.31 - 39,034.48 39,034.48
LED580/WW 8W 20D GM
SITC of LED Inground uplighter compact and robust design with diecast alluminuim housing and stainless
6.68 NSI trim, IP68 waterproof connectors equivalent toSignify Cat. No. BBP 344 LED 3600/WW 36W 20D 100- 5.00 Nos. 15,054.05 - 75,270.25 75,270.25
SITC of Updownlighter Housing in die-cast aluminium IP65/IK08 waterproof equivalent to Philips
Decorative Lighting Cat. No. 31450
Supplying and drawing following sizes of PVC insulated PVC sheathed copper conductor unarmoured
multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c
providing suitable copper lugs connections etc. complete in all respect as required.
Supply & laying of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and
PVC sheathed armoured cable in existing trenches/ Hume pipe/in ground as per IS : 7098:1988 with upto
date amendments complete in all respect as required.
Supplying and making end termination with brass compression gland and copper lugs for following size of
PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Digitally signed by ANUJ
Signature of Bidder Page 52 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing, laying and fixing following dia RCC pipe NP 2 class (light duty) in ground complete with RCC
14.14 collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and
refilling etc. as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings
SITC of following items for lightning protection AS PER IEC 62305 / IS IEC 62305
Air Termination Network:
SITC of single spike air terminals of 10 mm dia. & 1000 mm length as required and as per site conditions.
6.77 NSI The air terminal shall be manufactured with aluminium & shall be as per IEC 62561-2. The air terminal 5.00 Nos. 1,748.31 - 8,741.55 8,741.55
shall be fixed with necesarry clamping arrangement.
SITC of Roof Conductor for Parapet & Mesh : Supply of 8 mm dia aluminium round conductor for air
6.78 NSI termination network at parapet and for making mesh at terrace level and shall meet the requirement of IEC 386.00 RM 113.12 - 43,664.32 43,664.32
SITC of Parapet Conductor holder for holding of 8 mm dia. round conductor (for RCC roof). The
6.79 NSI conductor holder shall be mounted on plastic base support and shall meet the requirements of IEC 62561- 341.00 Nos. 169.68 - 57,860.88 57,860.88
4.It should be installed at every 1 mtr
SITC of Mesh Conductor holder for holding of 8 mm dia. round conductor (for RCC roof). The conductor
6.80 NSI holder shall be fixed on plastic support weighed by concrete block. It shall meet the requirements of IEC 45.00 Nos. 169.68 - 7,635.60 7,635.60
62561-4 and should be installed at every 1 mtr.
SITC of Bridging cable: Supply of 16sq.mm. copper cable along with lugs, having 500mm length & as per
IEC 62561-1 so as to connect air termination rod with any metallic structure on the roof
SITC of Straight - Connector for making straight joint of 8 mm Aluminium Conductor to 8 mm dia
Aluminium conductor on parapet wall, roof and vertical facade of masonery / glass / metallic work.
SITC of T - Connector for making Tee joint of 8 mm dia. Aluminium Conductor to 8 mm dia Aluminium
conductor on parapet wall, roof and vertical facade of masonery / glass / metalic work
DOWN CONDUCTOR AS PER IEC 62305
SITC of 8 mm dia aluminium round conductor for Down conductors to be installed on vertical wall, façade
of masonary / glass / metalic work. It shall meet the requirements of IEC 62561-2.
SITC of Wall Conductor holder for holding 8 mm dia. round conductor (for RCC wall). The conductor
6.85 NSI holder should be installed at every 1 mtr. The conductor holder shall be made with clamp mounted on 220.00 Nos. 169.68 - 37,329.60 37,329.60
plastic base support & as per IEC 62561-4.
SITC of Test Clamp to disconnect the down conductor from the earth termination network for regular
6.86 NSI checks of the earth termination resistance value. (with enclosure). It shall meet the requirements of IEC 7.00 Nos. 1,417.03 - 9,919.21 9,919.21
SITC of Expansion piece made of 8mm dia. Aluminium & as per IEC 62561-2 along with suitable
6.87 NSI connecting accessory. It shall be installed at every 20 mtr to maintain the flexibility to the conductor due to 20.00 Nos. 472.68 - 9,453.60 9,453.60
SITC of Lightning Strike counter Model: JMV 7D for counting the number of lightning strikes without any
6.88 NSI power supply. The Counter should be mounted on the Down Conductor. The Lightning Counter should be 1.00 Nos. 7,086.16 - 7,086.16 7,086.16
IP 65 rated enclosure suitable for external application.
Earth Termination Network:
SITC of Earthing termination made of copper-bonded rod of 10 feet length,14.2 mm dia. (Minimum
copper bonding shall be 0.25mm) as per IS 3043, IEEE-80, NBC 2016 along with Earth enhancement
material some with resistivity of 0.12 ohm-mtr, and complying IEC 62561-7 and Pit Cover complying IEC
62561-5 and other accessories as required and as per specification and other applicable codes
Digitally signed by ANUJ
Signature of Bidder Page 53 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
SITC of 8 mm CBS Conductor laid at 600mm below the ground, as Required and as per specification and
code of practice with Tee and Straight joint
Surge Protection Device:
SITC of Class B/Type I Single Phase Surge Protection Devices as per IEC 62305-4 and tested according to
IEC 61643 – 11, DIN Rail mountable with Maximum Continuous Operating Voltage of 320 V and Voltage
Protection Level of ≤ 2.5 kV. Response Time should be less than 100 ns. The maximum impulse test
current should be 50 kA (10/350 μs) per pole and 100 kA (10/350 μs) neutral to protective earth. The surge
protection devices shall be enclosed in polycarbonate enclosure of IP 65 rating
SITC of Class C/Type II Single Phase Surge Protection Devices as per IEC 62305-4 and tested according
to IEC 61643 – 11, DIN Rail mountable with Maximum Continuous Operating Voltage of 320 V and
6.92 NSI Voltage Protection Level of ≤ 1.5 kV. Response Time should be less than 25 ns. The maximum impulse 4.00 Nos. 4,723.77 - 18,895.08 18,895.08
discharge surge current should be 20 kA (8/20 μs) per pole and 40 kA (8/20 μs) neutral to protective earth.
The surge protection devices shall be enclosed in polycarbonate enclosure of IP 65 rating
MAIN LT PANEL (BUILDING MAIN PANEL)
MAIN LT PANEL & DISTRIBUTION PANEL
The rates for the distribution boards from the Breakers and instruments shall also include the following:
NOTE: The following provisions shall be required to be made in the switchboard detailed below:
The Switchboard shall have provision for entry of all PVC cables / bus duct from the top / bottom as
All live accessible parts shall be shrouded and all equipment shall be ginger touch proof. The busbar
insulation shall be with heat shrinkable sleeves SMC / DMC shrouds and busbar supports shall be used.
Suitable tinned copper extension links for incoming / outgoing cables shall be provided wherever required.
Control circuits includes breaker control switch, auto manual selector switch, anti pumping relay, spring
charging trip indication, TIMER, Control wiring, Auxiliary contactors MCB's as required at site.
All the incomers breaker shall be interlocked with micro PLC to avoid parallel operation . Stabilized
separate power supply to be provided for micro PLC hand wiring interlocking shall also be provided.
All the incomers breaker having microprocessor breaker shall have neutral CT
All fault level breaking capacity indicates shall be I.C.S. value at 415 volts. (ICS=ICU=ICW=100%) for 1
All MCCB above 250 Amp shall have variable overload and short circuit setting.
All ACB/MCCB shall have with Rotary Handles.
Space heater / light / air filter shall be provided for each vertical compartment.
Padlocking facility shall be provided on all outgoing feeders
All ACB's shall have all standard accessories such as CT,s Arc Chute, safety shutters etc.
All meter panel wiring from PLC to DG/TR/Bus coupler as required.
Link and drops from ACB / MCCB shall be designed for fall rated current of ACB / MCCB rating at same
amount of current density as of main busbar.
All panel should be on Ethernet with embedded web page to monitor ON/OFF/Trip status of the breaker.
Compliance to the technical specifications.
All MCCB in main panel should have O/L, S/C, E/F protection with S/C and E/F differtation.
Digitally signed by ANUJ
Signature of Bidder Page 54 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
All MFM shall have minimum sampling rate of 64 samples/cycle & feature of individual Harmonic
distortion upto 15th order.
MAIN LT PANEL (BUILDING MAIN PANEL)
Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase,
4Wire 50 Hz AC supply system, fabricated in compartmentalized design from CRCA sheet steel of 2mm
thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank
process for powder coating in approved shade, having 1250 Amp capacity extensible type FP Aluminium
Alloy bus bars of high conductivity, encapsulated with PVC sleeve, DMC/ SMC bus bar supports, with
short circuit withstand capacity of 50 MVA for 1 Sec., bottom base channel of MS section not less than
100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a
common copper earth bar of size 50mm x 6mm at the rear with 2 Nos. earth stud, 24V DC powerpack,
solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring
with 2.5sq.mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c
providing following switch gears:-
a) Air Circuit Breaker Horizontal drawout type LSIGUN protection and Data storage of last 20 trips and
80events.The ACB shal be of fault breaking capacity 50KA (Ics=lcu =Icw for 1 sec) upto 415V) Electrical
Draw Out Motorized operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF
and service/ test/isolated position indicators and frame earthing contact, conforming to IS-13947-2 1993 as
amended up-to-date complete with following accessories for each ACB
b) Independent Electrical / manual spring closing mechanism - I No.
c) Microprocessor release(EMI & EMC certified) for over current, earth fault & short circuit protection -
d) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication
interface port RS 485 for recording V ( Between Phases and between each phase and neutral ), A ( In each
Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with
suitable rating CTs etc. complete with wiring , connections etc.
e) 3 Nos. Phase indication LED lamps with 2Amp back up MCB, breaker 'ON/OFF' indicating light with
2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive
interlocking of the breakers as required.
f) Shunt trip coil 220V A.C.
g) 27-Undervoltage with definite time relay - 1 No
h) 1 No. DC under voltage trip relay
1 No. 1000 A, 4P, 50 KA ( BY IIT ROORKEE )
1250A, 4P Aluminium bus bar
Following rated 415V, ACB's/MCCB's with overcurrent and short circuit releases Microprocessor based
with ON,Trip indications, front operating handle & door interlock with 1 Set of three phase R,Y,B
indicating lamps along with 2A SP MCB backup protection and control terminals & wiring as required.
etc. complete with dual source MFM in all respects as mentioned in specifications and as required For
each outgoing: ( All Outgoings of Icu=Ics= 50 KA Rating)
800 A 35 KA, 4P MCCB - 1 No.(for Essential Panel)
630 A 35 KA, 4P MCCB - 1 No.(for outdoor AC Panel + spare)
63 A 35 KA, 4P MCCB - 1 No.(for External Lighting Feeder Piller)
6.930 NSI LT Panel Described as above complete 1.00 Set 4,75,881.00 - 4,75,881.00 4,75,881.00
Digitally signed by ANUJ
Signature of Bidder Page 55 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
6.940 NSI ESSENTIAL PANEL
Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase,
4Wire 50 Hz AC supply system, fabricated in compartmentalized design from CRCA sheet steel of 2mm
thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank
process for powder coating in approved shade, having 1000 Amp capacity extensible type FP Aluminium
Alloy bus bars of high conductivity, encapsulated with PVC sleeve, DMC/ SMC bus bar supports, with
short circuit withstand capacity of 50 MVA for 1 Sec., bottom base channel of MS section not less than
100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a
common copper earth bar of size 50mm x 6mm at the rear with 2 Nos. earth stud, 24V DC powerpack,
solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring
with 2.5sq.mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c
providing following switch gears:-
1No. 630A 4P Automatic transfer switch with 630 Amps 4 Pole, 35 KA, MCCB with thermal & magnetic
releases.with 3 Nos. R,Y,B Indication Lamps with 2A back up SP MCB with ON indication.MCCB shall
be provided with spreader link and direct rotary handle.
Dual core calibrated digital Multifuctional meter of class 1.0 to record demand (KVA), energy (KWH &
KVAH), power factor, current (in each phase and the neutral), volatge (between phases and between each
phase and neutral), Total haramonic distoration (THD) as a percentage of total current,and 3 Nos. dual core
CT of 630 /5 A Class 1.0 accuracy and 30 VA burden.
Shunt trip coil 220V A.C.
Following indicating lamps and push buttons for each CB with back up 2A SP MCB .
3 No. Phase indicating Lamps .
800A, TPN Aluminium bus bar
Following rated 415V, ACB's/MCCB's with overcurrent and short circuit releases Microprocessor based
with ON,Trip indications, front operating handle & door interlock with 1 Set of three phase R,Y,B
indicating lamps along with 2A SP MCB backup protection and control terminals & wiring as required.
etc. complete with dual source MFM in all respects as mentioned in specifications and as required For
each outgoing: ( All Outgoings of Icu=Ics= 35 KA Rating)
400 A 4P 25 KA MCCB - 2 Nos.(1 No.for Power Rising Main + spare )
315 A 4P 25 KA MCCB - 1 No.(Data Center )
160 A 25 KA, 4P MCCB - 3 Nos.( Ventilation Panel + UPS I/P Panel + spare)
125 A 25 KA, 4P MCCB - 3 Nos.(1 No.for Light Rising Main + I/D AC Panel + Ventilation Panel )
63 A 25 KA, 4P MCCB - 4 Nos.(for 3 Nos. Lift + spare )
6.940 NSI Essential panel Described as above complete 1.00 Set. 5,68,643.00 - 5,68,643.00 5,68,643.00
6.950 NSI Feeder Pillar for External Lighting
Digitally signed by ANUJ
Signature of Bidder Page 56 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, assembly, erection, connecting, testing & commissioning of LT weather proof dust and vermin
proof, outdoor feeder pillar, fabricated out of suitable sized angle iron and flats and covered with 3mm
thick CRCA sheet steel including canopy, duly stove enamel painted, both sides (front and rear) openable
with locking arrangement, rubber gasket cable glands, etc. Bakelite phase separators and bus bar supports
including PCC 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) foundation,
450 mm deep and 150 mm above the ground. The feeder pillars shall be complete with 3 phase and neutral
bus bars of capacities as described below and moulded case circuit breakers (MCCBs) with adjustable
overload relays for incomers and outgoing circuits ( including ON indication for each MCCB to be
provided) , complete in all respects as per specifications as required.
63A 4P MCB 10 kA - 1 No.
TPN bus bar of 100A rating
32A TPN MCB (10ka) - 4 nos.
40A TPN MCB (10ka) -1 nos.
40A, 4P Contactor - 1 No.
Astronomical Time Switch with daily dial - 1 No.
Auto Manual Selector Switch - 1 No.
63A DP MCB (10ka) - 6 nos.
6.950 NSI Feeder pilllar Described as above. 1.00 Set. 31,562.00 - 31,562.00 31,562.00
6.960 NSI DISTRIBUTION PANELS
Supplying, installation, testing & commissioning of cubical type wall mounted motor control Distribution
panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design
from CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning
& finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity
extensible type FP Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with
short circuit withstand capacity of 31 MV A for I Sec. with 2 Nos. earth stud, solid connections from main
bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. PVC
insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, i/c
additional NO/NC contacts in all outgoing starters for automatic operation through BMS and providing &
fixing following switch gears:-
1 No. - 100 Amps Four Pole, 35 KA (ICU=ICS), MCCB with adjustable thermal and adjustable magnetic
release, direct rotary handle.
Digital Multifuctional meter of class 0.5 or better accuracy to record demand (KVA), energy (KWH), Total
power factor, current (in each phase and the neutral), volatge (between phases and between each phase and
neutral), Total haramonic distoration (THD) as a percentage of total current, comprises of suitable
communication port for connection to IBMS.
TPN aluminium bus bars of minimum of 150 Amps capacity with heat shrinkable coloured sleeves and i/c
DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing
Digitally signed by ANUJ
Signature of Bidder Page 57 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
40 Amp 4P MCB '10 KA' - 4 Nos.
6.960 NSI Panel described as above 4.00 Set. 41,183.00 - 1,64,732.00 1,64,732.00
6.970 NSI POWER PANEL
1 No. -125 Amps Four Pole, 25 KA (ICU=ICS), MCCB with adjustable thermal and adjustable magnetic
release, direct rotary handle.
Digital Multifuctional meter of class 0.5 or better accuracy to record demand (KVA), energy (KWH), Total
power factor, current (in each phase and the neutral), volatge (between phases and between each phase and
neutral), Total haramonic distoration (THD) as a percentage of total current, comprises of suitable
communication port for connection to IBMS.
TPN aluminium bus bars of minimum of 150 Amps capacity with heat shrinkable coloured sleeves and i/c
DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing
63 Amp 4P MCB '10 KA' - 6 Nos.
6.970 NSI Panel described as above 4.00 Set 39,483.00 - 1,57,932.00 1,57,932.00
6.980 NSI UPS PANEL
1 No. -100 Amps Four Pole, 25 KA (ICU=ICS), MCCB with adjustable thermal and adjustable magnetic
release, direct rotary handle.
Digital Multifuctional meter of class 0.5 or better accuracy to record demand (KVA), energy (KWH), Total
power factor, current (in each phase and the neutral), volatge (between phases and between each phase and
neutral), Total haramonic distoration (THD) as a percentage of total current, comprises of suitable
communication port for connection to IBMS.
TPN aluminium bus bars of minimum of 150 Amps capacity with heat shrinkable coloured sleeves and i/c
DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing
63 Amp 4P MCB '10 KA' - 5 Nos.
6.980 NSI Panel described as above 4.00 Set 39,285.00 - 1,57,140.00 1,57,140.00
6.990 NSI UPS Panel
Supplying, installation, testing & commissioning of cubical type wall mounted motor control L T panel
suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from
CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning &
finishing complete with 7 tank process for powder coating in approved shade, having Suitable capacity
extensible type FP Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with
short circuit withstand capacity of 31 MV A for I Sec. with 2 Nos. earth stud, solid connections from main
bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. PVC
insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, i/c
additional NO/NC contacts in all outgoing starters for automatic operation through BMS and providing &
fixing following switch gears:-
Digitally signed by ANUJ
Signature of Bidder Page 58 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
UPS INPUT PANEL
1 No. - 160 Amps Four Pole, 25 KA MCCB (Icu=Ics) with micro processor based releases with 3 Nos.
R,Y,B Indication Lamps with 2A back up SP MCB with ON,Trip indication.MCCB shall be provided with
spreader link and direct rotary handle
FP CU. bus bars of minimum of 200A 35 kA capacity with heat shrinkable coloured sleeves and i/c
DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing
3 No. 100A 4P MCCB having breaking capacity 25 KA (Ics=Icu) with thermal magnetic releaase with
o/c,s/c protection release all indication,front operating handle & door interlock.
6.990 NSI panel described as above 1.00 Set 98,014.00 - 98,014.00 98,014.00
6.100 NSI UPS OUTPUT PANEL
3 Nos. - 100 Amps Four Pole, 25 KA (ICU=ICS), MCCB with adjustable thermal and adjustable magnetic
release, direct rotary handle. (necessary interlocking to be done of both incomers)
Digital Multifuctional meter of class 0.5 or better accuracy to record demand (KVA), energy (KWH), Total
power factor, current (in each phase and the neutral), volatge (between phases and between each phase and
neutral), Total haramonic distoration (THD) as a percentage of total current, comprises of suitable
communication port for connection to IBMS.
FP copper bus bars of minimum of 150 A capacity with heat shrinkable coloured sleeves and i/c
DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing
160 Amp. 4P MCCB 25KA with E/L protection- 25KA - 2 No.(UPS Rising Main + Spare)
63Amp TPN MCB '10 KA' - 4 Nos . (spare)
6.100 NSI Panel described as above 1.00 Set 1,99,675.00 - 1,99,675.00 1,99,675.00
6.101 NSI AC Panel for indoor units
Digitally signed by ANUJ
Signature of Bidder Page 59 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, installation, testing and comissioning of dust, damp and vermin proof cubicle free floor, indoor
type factory built sheet steel enclosed modular bolted construction extendable Panel, suitable for operation
on 415 ±10% volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of Form 3b compartmentalized
design and covered with CRCA sheet steel of 2mm thick for frame work and 1.6mm thick for doors/
covers, 3mm thick for gland plates i/c cleaning & finishing complete with 9 tank process for powder
coating in approved shade, having extensible type TPN Aluminium bus bars of high conductivity, SMC
bus bar supports, with short circuit with stand capacity of 35KA for 1 sec., bottom base channel of section
not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a
common copper earth bus bar to switch gears with required size of Alum. bus bars and inter-connection
with solid copper conductor wires/ aluminium strips, neutral links, including control wiring with 1.5sqmm.
PVC insulated FRLS copper conductor Single Core cable for voltage & 2.5sq.mm for current circuits, cable
alleys, cable gland plates in two half, danger notice plates, etc. necessary metering protections &
indications and mounted with the following switch gears as per drawing and technical specifications etc.
complete as required.
1No. 125 Amp 433V, 4P MCCB of 25 kA Breaking capacity with On Indica ting Lamp with 2A SP MCB
Metering incoming:
Each Incomer (Ics=lcu) with O/L, S/C & built-in earth fault protection
1 Set of phase indicating lamp with 2Amps SP MCB back-up.
TPN aluminium extensible type main bus bars of minimum of 150 Amp capacity and auxiliary bus bar of
suitable capacity with heat shrinkable coloured sleeves and i/c SMC bus bars supports at required intervals
complete for cross section, size supports & their spacing etc. for withstanding fault level of 25kA capacity.
63A 4P MCB 10 kA- 12Nos.
40A 4P MCB 10 kA- 6Nos.
G.I. earth strip as per calculation with holes,GI nut bolt washers etc. - 2 set
Inter connecting cables/ control wiring with FRLS copper wires etc. as required complete.
Each outgoing breaker shall have the following accessories-
All control wiring required shall be included here.
6.102 NSI AC outdoor type PANEL
Digitally signed by ANUJ
Signature of Bidder Page 60 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, installation, testing and comissioning of dust, damp and vermin proof cubicle free floor, outdoor
type factory built sheet steel enclosed modular bolted construction extendable Panel, suitable for operation
on 415 ±10% volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of Form 3b compartmentalized
design and covered with CRCA sheet steel of 2mm thick for frame work and 1.6mm thick for doors/
covers, 3mm thick for gland plates i/c cleaning & finishing complete with 9 tank process for powder
coating in approved shade, having extensible type TPN Aluminium bus bars of high conductivity, SMC
bus bar supports, with short circuit with stand capacity of 35KA for 1 sec., bottom base channel of section
not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a
common copper earth bus bar to switch gears with required size of Alum. bus bars and inter-connection
with solid copper conductor wires/ aluminium strips, neutral links, including control wiring with 1.5sqmm.
PVC insulated FRLS copper conductor Single Core cable for voltage & 2.5sq.mm for current circuits, cable
alleys, cable gland plates in two half, danger notice plates, etc. necessary metering protections &
indications and mounted with the following switch gears as per drawing and technical specifications etc.
complete as required.
1No. 630 Amp 433V, 4P MCCB of 25 kA Breaking capacity with On Indica ting Lamp with 2A SP MCB
Metering incoming:
Each Incomer (Ics=lcu) with O/L, S/C & built-in earth fault protection
1 Set of phase indicating lamp with 2Amps SP MCB back-up.
TPN aluminium extensible type main bus bars of minimum of 800 Amp capacity and auxiliary bus bar of
suitable capacity with heat shrinkable coloured sleeves and i/c SMC bus bars supports at required intervals
complete for cross section, size supports & their spacing etc. for withstanding fault level of 25kA capacity.
63 Amp. 4P MCCB 25KA with E/L protection- 25KA - 14 set
40A 4P MCB 10 kA with E/L protection- 8Nos.
G.I. earth strip as per calculation with holes,GI nut bolt washers etc. - 2 set
Inter connecting cables/ control wiring with FRLS copper wires etc. as required complete.
Each outgoing breaker shall have the following accessories-
All control wiring required shall be included here.
6.103 NSI ventilaton Indoor type PANEL
Digitally signed by ANUJ
Signature of Bidder Page 61 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, installation, testing and comissioning of dust, damp and vermin proof cubicle free floor, Indoor
type factory built sheet steel enclosed modular bolted construction extendable Panel, suitable for operation
on 415 ±10% volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of Form 3b compartmentalized
design and covered with CRCA sheet steel of 2mm thick for frame work and 1.6mm thick for doors/
covers, 3mm thick for gland plates i/c cleaning & finishing complete with 9 tank process for powder
coating in approved shade, having extensible type TPN Aluminium bus bars of high conductivity, SMC
bus bar supports, with short circuit with stand capacity of 35KA for 1 sec., bottom base channel of section
not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a
common copper earth bus bar to switch gears with required size of Alum. bus bars and inter-connection
with solid copper conductor wires/ aluminium strips, neutral links, including control wiring with 1.5sqmm.
PVC insulated FRLS copper conductor Single Core cable for voltage & 2.5sq.mm for current circuits, cable
alleys, cable gland plates in two half, danger notice plates, etc. necessary metering protections &
indications and mounted with the following switch gears as per drawing and technical specifications etc.
complete as required.
1No. 160 Amp 433V, 4P MCCB of 25 kA Breaking capacity with On Indica ting Lamp with 2A SP MCB
Metering incoming:
Each Incomer (Ics=lcu) with O/L, S/C & built-in earth fault protection
1 Set of phase indicating lamp with 2Amps SP MCB back-up.
TPN aluminium extensible type main bus bars of minimum of 200 Amp capacity and auxiliary bus bar of
suitable capacity with heat shrinkable coloured sleeves and i/c SMC bus bars supports at required intervals
complete for cross section, size supports & their spacing etc. for withstanding fault level of 25kA capacity.
100 Amp. 4P MCCB 25KA with E/L protection- 25KA - 1 set
63Amp TP,10 kA MCB with Fully automatic DOL starter suitable for operating 7.5 kw motors/fan
capacity, complete with contactors,Timer, overload protection relay, current sensing type single phase
preventer, ON indications, push buttons, auto / manual / off selector switch,other accessories. complete as
required.-2 Nos.(fans)
40Amp TP,10 kA MCB with Fully automatic DOL starter suitable for operating 3.7 kw motors/fan
capacity, complete with contactors,Timer, overload protection relay, current sensing type single phase
preventer, ON indications, push buttons, auto / manual / off selector switch,other accessories. complete as
required.-6 Nos.(fans)
63A 4P MCB 10 kA with E/L protection- 2Nos. (spare)
G.I. earth strip as per calculation with holes,GI nut bolt washers etc. - 2 set
Inter connecting cables/ control wiring with FRLS copper wires etc. as required complete.
Each outgoing breaker shall have the following accessories-
All control wiring required shall be included here.
6.104 NSI ventilaton outdoor type PANEL
Digitally signed by ANUJ
Signature of Bidder Page 62 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, installation, testing and comissioning of dust, damp and vermin proof cubicle free floor, outdoor
type factory built sheet steel enclosed modular bolted construction extendable Panel, suitable for operation
on 415 ±10% volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of Form 3b compartmentalized
design and covered with CRCA sheet steel of 2mm thick for frame work and 1.6mm thick for doors/
covers, 3mm thick for gland plates i/c cleaning & finishing complete with 9 tank process for powder
coating in approved shade, having extensible type TPN Aluminium bus bars of high conductivity, SMC
bus bar supports, with short circuit with stand capacity of 35KA for 1 sec., bottom base channel of section
not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a
common copper earth bus bar to switch gears with required size of Alum. bus bars and inter-connection
with solid copper conductor wires/ aluminium strips, neutral links, including control wiring with 1.5sqmm.
PVC insulated FRLS copper conductor Single Core cable for voltage & 2.5sq.mm for current circuits, cable
alleys, cable gland plates in two half, danger notice plates, etc. necessary metering protections &
indications and mounted with the following switch gears as per drawing and technical specifications etc.
complete as required.
1No. 100 Amp 433V, 4P MCCB of 25 kA Breaking capacity with On Indica ting Lamp with 2A SP MCB
Metering incoming:
Each Incomer (Ics=lcu) with O/L, S/C & built-in earth fault protection
1 Set of phase indicating lamp with 2Amps SP MCB back-up.
TPN aluminium extensible type main bus bars of minimum of 800 Amp capacity and auxiliary bus bar of
suitable capacity with heat shrinkable coloured sleeves and i/c SMC bus bars supports at required intervals
complete for cross section, size supports & their spacing etc. for withstanding fault level of 25kA capacity.
63A 4P MCB 10 kA with E/L protection- 2Nos. (HRW unit)
40A 4P MCB 10 kA with E/L protection- 2Nos. (HRW unit)
63Amp TP,10 kA MCB with Fully automatic DOL starter suitable for operating 5.5 kw motors/fan
capacity, complete with contactors,Timer, overload protection relay, current sensing type single phase
preventer, ON indications, push buttons, auto / manual / off selector switch,other accessories. complete as
required.-4 Nos.(fans+terrace pump)
25Amp TP,10 kA MCB with Fully automatic DOL starter suitable for operating 2.2 kw motors/fan
capacity, complete with contactors,Timer, overload protection relay, current sensing type single phase
preventer, ON indications, push buttons, auto / manual / off selector switch,other accessories. complete as
required.-3 Nos.(fans)
G.I. earth strip as per calculation with holes,GI nut bolt washers etc. - 2 set
Inter connecting cables/ control wiring with FRLS copper wires etc. as required complete.
Each outgoing breaker shall have the following accessories-
All control wiring required shall be included here.
RISING MAINS & TAP OFF BOXES, END FEED UNIT PANELS
Digitally signed by ANUJ
Signature of Bidder Page 63 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following
capacity Sandwich Type Rising Mains as per IEC61439 for use on 3 phase 4 wire 415 V, 50Hz A.C.
supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made
of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus
bars , necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of
tapping at every meter, adopter box and copper flexible for joints, continuous earthing with 2 Nos.
aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle
iron bracket, steel fasteners, connecting to earthing system etc. as required.
For Type- III & IV quarter
Supplying, installation, testing & commissioning of following capacity Plug In/ tap off box on the existing
Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply
made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB (but
without MCCB) complete etc. as required
Supplying, installation, testing & commissioning of following capacity End Feed Unit for the existing
rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply made with 1.6mm thick steel sheet
3.11 enclosure (IP54) duly powder coated with provision of MCCB/ ACB (but without MCCB/ACB) complete
with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to
earthing system etc. as required
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release
and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making
connections, etc. as required.
CABLES & CABLE TRAY
Supply of following sizes of PVC sheathed LT XLPE armoured, aluminium / copper cable 1.1KV grade, as
required of the following sizes.
Digitally signed by ANUJ
Signature of Bidder Page 64 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of
following size on cable tray as required.
6.137 7.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) 4780.00 Mtr 33.33 1,59,317.40 - 1,59,317.40
6.138 7.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 290.00 Mtr 74.74 21,674.60 - 21,674.60
6.139 7.8.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 165.00 Mtr 93.93 15,498.45 - 15,498.45
6.140 7.8.4 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 2620.00 Mtr 151.50 3,96,930.00 - 3,96,930.00
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply, installation, testing & commisioning of cable termination of above cables with copper lugs &
Double compression compression glands on both the ends with inhibting compound etc. complete as
Supply, laying, testing & commisioning of LPCB/BRE/TUV approved Fire Survival armoured cable as per
BS 7846, fire Test as per BS 6387 CWZ, copper conductor /mica taped/ Flame Barrier/ Cross Linked
NSI Insulation/ Halogen Free Inner Sheath/ SWA/ Halogen Free Outer Sheath (1000V), LPCB/BRE Certified
for power cables. etc. complete as required. (Tagging to be provided with aluminium strips on both the
ends as approved).
Supply, installation, testing & commisioning of cable termination of above cables with copper lugs &
flameproof brass compression glands on both the ends for fire survival cable with inhibting compound etc.
complete as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation
thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined
with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as
Digitally signed by ANUJ
Signature of Bidder Page 65 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends"
(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections,
joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee"
(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections,
joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer"
(galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections,
joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
with charcoal/ coke and salt as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry
6.177 5.2 enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt 4.00 Each 5,361.08 21,444.32 - 21,444.32
as required.c with cover & chamber. Complete in all respects as per direction of E/I.
Providing and fixing 50 mm X 6 mm size of G.I. strip in 80 mm dia 'B' class G.I. pipe from earth electrode
6.179 NSI Providing and fixing 50 mm X 6 mm G.I. strip on surface or in recess for connections etc, as required 300.00 Mtr. 347.44 - 1,04,232.00 1,04,232.00
Providing and fixing 50 mm X 6 mm size of copper strip in 80 mm dia 'B' class G.I. pipe from earth
electrode as required
6.181 NSI Providing and fixing 50mm X 6 mm copper strip on surface or in recess for connections etc, as required 40.00 Mtr. 3,563.28 - 1,42,531.20 1,42,531.20
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode,
6.182 5.9 including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be 50.00 Mtrs. 132.31 6,615.50 - 6,615.50
done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. Pipe FRLSom earth electrode including
connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Digitally signed by ANUJ
Signature of Bidder Page 66 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (ELECTRICAL WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Providing and fixing 25 mm X 3 mm copper strip in 40 mm dia G.I. Pipe FRLSom earth electrode
including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing
surface/ recessed conduit/ submain wiring/ cable as required.
Supply and fixing of following GI strip/ wire including all necessary fixing accessories and effecting
connections as required & approved by the Engineer Incharge.
Supply and fixing in position the best quality L.T. Danger Notice plate of 200mm x 150mm,made of mild
6.189 2.21 steel atleast 2mm thick and vitreous enamelled, white on both sides and with inscription in signal red 6.00 Nos. 228.26 1,369.56 - 1,369.56
colour on front side written in English & Hindi as required.
Supply and fixing in position 1000mm wide checkered rubber matting of 1.1KV grade as per electricity
rules,with thickness not less than 12mm.
LT panel, Lift Panel, Fire fighting panels, Server Room etc.
Make: Supremex/ Lifeguard/ Firetrace/ Firetrex/ Kalpex
Supplying, installing, testing and commissioning of followings:
SITC of 2kg capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube,
6.191 NSI Novec 1230, mounting bracket, End of Line adopter and low pressure switch for monitoring system 1.00 Nos 54,323.86 - 54,323.86 54,323.86
SITC of 4kg capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube,
6.192 NSI Novec 1230, mounting bracket, End of Line adopter and low pressure switch for monitoring system 2.00 Nos 67,728.58 - 1,35,457.16 1,35,457.16
6.193 NSI SITC of Linear pneumatic heat Detection Tube with all necessary fittings & supports. 150.00 Mtr 1,562.47 - 2,34,370.50 2,34,370.50
6.194 NSI SITC of Audio Visual Alarm Gas Based System 3.00 Nos 6,085.25 - 18,255.75 18,255.75
SECTION - XII - UPS
Supply, Installation, Testing and Commissioning of online load sharing 40 KVA UPS system in parellel
redundant mode of operation following ratings with computer communication possibilities consisting of
standard software, double conversion system suitable for providing power supply to computers/servers
sports lighting, corridor lighting delivery atleast 30 minutes backup, suitable for incoming 415 volts,
3phase +15% -15%, 50Hz supply and three phase output voltage, including, rectifier/dual converter,
bypass switch, inverter, filter. Bypass & static transfer switch for automatic switch over, providing static
bypass module, high switching frequency microprocessor based with built-in technical protections like
short circuits, over load, high / low voltage cut off protection of load from source inclusive of bypass
facility without giving any break of power, maintenance bypass switch and phase reverse preventor. The
UPS should have IGBT based rectifier and IGBT based inverter.The UPS shall be provided with Isolation
transfomrer. The UPS should also give minimum 94% efficiency at 100% load. UPS shall be BMS
compatible including communication module / card as required without any additional cost
Microprocessor/ software controlled annunciation, protection (including against input phase reversal), and
menu run diagnostic module, associated cabling, connections, termination, erection including associated
foundation/ masonry or RCC work for mounting on base channels etc. complete as required and as per
specifications.
Providing & Fixing of VRLA Battery Banks and BCB consisting of (….AH x 2V x ….Nos.) Cells SMF
Type suitable for UPS System for 30 mins backup for individual UPS.
Note:- Please also attach battery back up calculation alongwith quotation.
6.195.1 NSI Note :- Total 3 Sets x 40 KVA UPS are Planned for the project. 3.00 Set 8,82,950.00 - 26,48,850.00 26,48,850.00
Digitally signed by ANUJ
Signature of Bidder Page 67 of 90 GULIA Signature of NBCC
NBCC (INDIA) LIMITED
(A Govt.of India Navratna CPSE)
NAME OF THE WORK :-CONSTRUCTION OF BALANCE WORKS OF MEHTA FAMILY SCHOOL OF DATA SCIENCE AND
ARTIFICIAL INTELLIGENCE (MFSDSAI) INCLUDING INTERNAL EL, HVAC, FIREFIGHTING, FIRE ALARM, LIFTS, AUDIO
VISUAL SYSTEM, CCTV AND BMS INSTALLATION AND DEVELOPMENT WORKS AT I IT ROORKEE, UTTARAKHAND
NAME OF CLIENT :- IIT ROORKEE
NAME OF THE BIDDER :-
SUMMARY SHEET- LIFTS WORKS
SI. NO DESCRIPTION OF ITEM
DSR N.S.I. Total
Signature of Bidder Page No 68 of 90 Signature
Digitally signed of
NBCC (INDIA) LIMITED
NAME OF THE WORK :-CONSTRUCTION OF BALANCE WORKS OF MEHTA FAMILY SCHOOL OF DATA SCIENCE AND ARTIFICIAL INTELLIGENCE (MFSDSAI) INCLUDING INTERNAL
EL, HVAC, FIREFIGHTING, FIRE ALARM, LIFTS, AUDIO VISUAL SYSTEM, CCTV AND BMS INSTALLATION AND DEVELOPMENT WORKS AT I IT ROORKEE, UTTARAKHAND
SCHEDULE OF QUANTITIES (LIFT WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
1 1 Lifts- SUBHEAD-1
Design, Fabrication, Supply, Installation, Testing & Commissioning of 16 Passenger lift (1360Kg)
Electronic Traction Type fully automatic gearless and machine room less elevator with contract speed
of 1.5 mps for passenger lift serving different floors in the lift shaft of size 2600mm (W) x 2200mm
(D), 2150 mm pit depth and 4800 mm overheadas per detailed specifications enclosed and as under:-
Location of lift: IIT Roorkee -2 Nos. (1 bank of 2 lifts )
Number of Landings (i.e. Stops) -
Ground+ 3 = 4 Floors
Travel Height - 15.1 Mtrs (approx.)
No. Of Openings - 4 Stop & 4 opening (all opening be on same side)
Drive System & Control - Micro Processor based VVVF, Integrated Controller In Door Frame) or
Alternating Current Voltage Frequency (ACVF) with Closed Loop system with Gearless Motor
Operation - Microprocessor based duplex collective selective - (with/without -attendant)
Power: 415 Volts+10%, 3 Phase 4 wire 50 Hz AC system. And Auxilary power Supply :230 V ± 10%, 50 Hz
single phase supply.
(a) Car : Power operated automatic horizontal sliding center opening SS hairline finish.
(b) Landing doors : 2 Hrs Fire Rated and SS hairline finish in all floors.
Side wall in SS Hairline Finish and Exterior side wall with see through transparent glass panel.
(x) Car Door width of 900mm-1200 (min) for passenger lift (As per car standard size )
Car Ceiling - SS- Finish Hairline
Car Walls & Doors Finish - SS - Finish (Scratch resistant) on all sides.
Car Floor - Granite Flooring
Mirror - Not Required
Sill - Aluminium profiles
Lift Car Operating Panel(COP) shall be glass touch sensitive having option of door open/close, digital
alarm button, position & visual direction indicator. Landing Operating Panel(LOP) should be Glass
Touch Sensitive and wall mounted with visual call acceptance. Digital car positions indicator in car &
at all floors with up / down direction indications
Control panel in the car and hall button panel at each landing. Braille buttons inside the car and at all
Car Lighting - LED light, Minimum 50 lux on floor and on Car operating Panel. Auto fan and light off option
Handrail - SS Finish on the rear wall and not less that 600mm long at 900mm above floor level to be fixed
adjacent to control panel in the lift car.
Car Walls - Minimum 6mm Thick
Digitally signed by ANUJ
Signature of Bidder Page 69 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (LIFT WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Decoration Skirting & Corners - Must be Anodised for weather protection
Recess Flooring (for Owners) - 25mm
Control & Fixtures Details -
Landing display - 16-segment Car position and direction of travel display and Lift under maintenance
Emergency Alarm - Alarm with Rechargeable Sealed Maintenance Free batteries.
Over load warning - Audio/ Visual Overload warning indicator to be provided.
Voice Synthesizer in car - Floor and door open/close Voice Announcement
Car Display - 16-segment LED Dynamic Car Direction display & Digital position indicators
Infra-red Light Curtain (Full Length) on Car doors - To be provided
Auto Light/Fan Cutoff - Ventilation fan ON OFF switch with auto switch off feature
Door open/ Door Close - Door open and Door Close buttons with Symbol markings.
ARD operation Audio / Visual indication in car - To be provided
Emergency Alarm Button - Emergency Alarm button with Bell symbol & the same should be at a distinct
distance from the call buttons.
Intercom - To be provided (i.e. 3-way intercom)
Hall Buttons - To be provided as per the Tenderer
Out of Service Mode - To be provided
Attendant Operation - To be provided
Power Supply -3 x 415V /220V, 50 Hz
Acceptable Voltage Fluctuation - +10% to -15%
Acceptable Frequency Fluctuation - +/- 5%
Rate of Acceleration/Deceleration M/s2 - < 0.5 meter per second square
Jerk( m/sec3) - < 1 meter per second cube
Horizontal Vibration X/Y (mPtP) - < 15mg (As per ISO 18738)
Vertical Vibration Z - < 25 mg (As per ISO 18738)
Airborne Noise Levels - 50 ± 3 dBa
Airborne Noise level in Car (without Fan) - Max 60 dBa
Airborne Noise level in front of closed Hoistway door (when car passing by) - Max 53 dBa
Stopping Accuracy - ± 3mm
Elongation - ± 20mm
Leveling Accuracy - ± 10mm
Door Drive - Compact VVVF closed loop
Car panel & Door panel thickness - Atleast 1.6 mm
Maximum Number of trips Per Hour - < 180
Safety Features & Other Inclusions
Door Protection - Multi beam infrared protection device so as to reverse the closing door in case of slight
obstruction in the door way.
Anti nuisance - To Be provided
Fire Man Control - To Be provided
Over Load detection Device - To Be provided
Buffers - Spring Buffers
Safety Governor - Electro-Mechanical type Safety governors for Car.
Safety Instructions - Do’s & Don’ts with emergency contact Numbers must be provided & displayed in
Over travel protection - Terminal and final limit switches to be provided.
Digitally signed by ANUJ
Signature of Bidder Page 70 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (LIFT WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Controller / Drive / Motor Protection - Trip Device for Over current, Under Voltage and Over voltage than
the rated capacity. + 10%
· Motor overload / over torque
· Instantaneous over current
· Under voltage
· Over voltage – 3 phase
· Output & Input phase loss
· Phase reversal
· Output short circuit
· Spikes & Surges
Protection with the Sudden surges/spikes in level in voltage alongwith shifting of neutral and earth
leading to improper earthing (Must be provided as a separate kit.)
ARD (Automatic Rescue Device) - ARD to be provided. (Detailed Literature of Make and working of ARD
to be provided separately).
Fire Rating of Landing doors - Landing doors must have 2 hour fire resistance rating and Elevator
supplier must provide the Fire-certificate for the same from Accrediated laboratory.
Self adjustment & self Daigonastic - To be provided
Intercom connection - Must be provided in 3-way
Fascia Plates & Sill angles - Full height Fascia Plates and Sill angles to be provided (or as per the IS
Code Guidelines)
Pit Ladder - MS Pit ladder to be provided and securely fastened inside the pit.
Counter Weights - In case of non-metallic filler weights, the counterweight sections shall be totally
enclosed in a metallic covering.
Major Components Service Life:-
· Ropes / Belts :- 8 years
· Over speed governor:- 20 years
· Traction machine /motor:- 20 years
· Door operator:- 20 years
· Safety gear / block :- 25 years
· Travelling cables:- 20 years
· Inverter Drive:- 20 years
· Buffer:- 20 years
Voice Announcement - Voice announcement to announce the Floor position as well as door open/door
close. Voice announcement system in the car to announce the position of the elevator in the hoist way as
the car passes or stops at floor served by the elevator.
Infra-red Light Curtain (Full Length) on Doors - To be provided - Multi beam infrared protection device
so as to reverse the closing door in case of slight obstruction in the door way.
1.1 NSI Passenger lift as described as above 2.00 Each 23,02,557.60 - 46,05,115.20 46,05,115.20
Design, Fabrication, Supply, Installation, Testing & Commissioning of 20 Passenger cum stretcher lift fully
automatic gearless and machine room less elevator with contract speed of 1.5 mps for passenger lift
serving different floors in the lift shaft of size 2500mm (W) x 3000mm (D), 2150 mm pit depth and 4800 mm
overheadas per detailed specifications enclosed and as under:-
Location of lift: IIT Roorkee- 1No. (1 bank of 1 lifts )
Number of Landings (i.e. Stops) -
Ground+ 3 = 4 Floors
Travel Height - 15.1 Mtrs (approx.)
No. Of Openings - 4 Stop & 4 opening (all opening be on same side)
Digitally signed by ANUJ
Signature of Bidder Page 71 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (LIFT WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2021 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Drive System & Control - Micro Processor based VVVF, Integrated Controller In Door Frame) or
Alternating Current Voltage Frequency (ACVF) with Closed Loop system with Gearless Motor
Automatic Rescue Device (ARD) compete with dry maintenance free batteries as required.
Operation - Microprocessor based simplex collective selective - (with/without -attendant)
Power: 415 Volts+10%, 3 Phase 4 wire 50 Hz AC system. And Auxilary power Supply :230 V ± 10%, 50
Hz single phase supply.
(a) Car : Power operated automatic horizontal sliding center opening SS hairline finish.
(b) Landing doors : 2 Hrs Fire Rated and SS hairline finish in all floors.
All Side wall in SS Hairline Finish
other details same as above
1.2 NSI Service lift as described as above 1.00 Each 23,57,380.40 - 23,57,380.40 23,57,380.40
Digitally signed by ANUJ
Signature of Bidder Page 72 of 90 GULIA Signature of NBCC
NBCC (INDIA) LIMITED
(A Govt.of India Navratna CPSE)
NAME OF THE WORK :-CONSTRUCTION OF BALANCE WORKS OF MEHTA FAMILY SCHOOL OF DATA SCIENCE AND ARTIFICIAL
INTELLIGENCE (MFSDSAI) INCLUDING INTERNAL EL, HVAC, FIREFIGHTING, FIRE ALARM, LIFTS, AUDIO VISUAL SYSTEM, CCTV AND
BMS INSTALLATION AND DEVELOPMENT WORKS AT I IT ROORKEE, UTTARAKHAND
NAME OF CLIENT :- IIT ROORKEE
NAME OF THE BIDDER :-
SUMMARY SHEET- HVAC WORKS
SI. NO DESCRIPTION OF ITEM
DSR N.S.I. Total
1 HVAC WORKS - EQUIPMENTS SUBHEAD-1 ₹ 0.00 ₹ 1,61,08,365.77 ₹ 1,61,08,365.77
2 HVAC WORKS - VENTILATION SUBHEAD-2 ₹ 0.00 ₹ 6,30,971.24 ₹ 6,30,971.24
3 HVAC WORKS - AIR DISTRIBUTION SUBHEAD-3 ₹ 33,95,838.67 ₹ 12,59,197.05 ₹ 46,55,035.71
4 HVAC WORKS - INSULATION SUBHEAD-4 ₹ 27,06,769.70 ₹ 0.00 ₹ 27,06,769.70
5 HVAC WORKS -WATER PURIFIER CUM WATER COOLER SUBHEAD-5 ₹ 0.00 ₹ 2,72,296.00 ₹ 2,72,296.00
Signature of Bidder Page No 73 of 90 DigitallySignature
signed byof ANUJ
NBCC (INDIA) LIMITED
NAME OF THE WORK :-CONSTRUCTION OF BALANCE WORKS OF MEHTA FAMILY SCHOOL OF DATA SCIENCE AND ARTIFICIAL INTELLIGENCE (MFSDSAI) INCLUDING INTERNAL EL, HVAC,
FIREFIGHTING, FIRE ALARM, LIFTS, AUDIO VISUAL SYSTEM, CCTV AND BMS INSTALLATION AND DEVELOPMENT WORKS AT I IT ROORKEE, UTTARAKHAND
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
1 1 HVAC WORKS - EQUIPMENTS SUBHEAD-1
1.1 1.1 VRF Outdoor UNITS
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable
Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically
sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,
microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,
vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated
capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall
be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first
charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less
than 3.1 and IEER not less than 6.5
For enhancement energy saving and better efficiency particular to the project requirement, recommended
min. COP @ AHRI condition should be 3.7@ 100% load and 7.5 @ 50% load of each refrigerant circuit
Final Configuration/ selection of module for ODU to be done accordingly to meet the required COP by
1.2 1.2 VRF INDOOR UNITS-4Way flow Cassette type Unit
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF
Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section
with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil,
electronic expansion valve, outer cabinet, high lift drain pump, grill, necessary supports, vibration
isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC
supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on
receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27
Degree C DB and 19 Degree C WB temperature.
1.3 1.3 VRF INDOOR UNITS-1Way/ Corner Type Cassette Unit
Supply, installation, testing and commissioning of following minimum capacity 1-way flow/ Corner type
VRV/VRF Cassette Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan
section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper
coil, electronic expansion valve, outer cabinet, high lift drain pump, grill, necessary supports, vibration
isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC
supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on
receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27
Degree C DB and 19 Degree C WB temperature.
1.4 1.4 VRF INDOOR UNITS-HIGH WALL TYPE
Digitally signed by ANUJ
Signature of Bidder Page 74 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type
Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer
cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V
± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut
down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit
will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
1.5 1.5 FLOOR MOUNTED AIR HANDLING UNITS
Supply, installation, testing and commissioning of Factory built double skin DX based Floor Mounted air
handling units made of 25mm thick panels consisting of pre coated G.I. casing of thickness 0.8mm
outside layer and 0.8mm thick plane GI inside layer with polyurethene foam (PUF) insulation of density
38kg/m3 factory injected between them by injection moulding machine,complete with blower section with
blower DIDW backward curved centrifugal fan with suitable static pressure, Multi rows (4/6/8 rows)
deep VRF based Cooling Coil Section (coil shall be with aluminium finned copper tubes(tube
thickness not less than 0.4mm)), 50mm thick prefilter section equivalent to MERV-8 rating, Super Fine
filter (MERV-14), belt drive package with TEFC drive motor (IE-3) with IP-54/55 protection and 415+/-,
10% volts, 50 Hz, 3 phase, A.C. supply, drain connections with drain valve, insulated stainless steel drain
pan, fire rated flexible inside AHU, necessary vibration isolation arrangement, gravity louvers
etc,complete as per specifications of following capacities.Suitable capacity of TPN isolator for FM AHU
within MS enclosure for AHU to be provided.
AHU with 30mmwg External Static pressure
Supply, Installation, testing and commissioning of AHU communication Kits (Based on total nos.
of Refrifgerant Ckt) complete including DX-Type electronic expansion valve, control box and all
arrangement including valves, control wiring, thermostat etc. accessories to be provided.
Supply, Installation, testing and commissioning of necessary fittings, Y-joints (Refnets) and headers for
VRF system complete in all respect.
1.8 1.8 CENTRALIZED CONTROLLER FOR VRF SYSTEM
Supplying, fixing, testing and commissioning of Main centralized controller Push Button Type suitable for
groups of indoor units to be installed for control (BMS Compatible). All required accessories (hardware
and software) to be provided for BMS connection. Controller shall have software for automation
(ON/OFF, scheduling, lock/unlock, temperature setting, error detection) of entire system, all indoor units
1.8.1 NSI add monitoring of corresponding outdoor units from one central location. Controller should be BMS (like 1.00 Set 30,152.54 - 30,152.54 30,152.54
Bacnet, Lan works, Modbus) compatible. It must show the status of all indoor units along with outdoor
unit. All required accessories (hardware and software) to be provided for BMS connection. Controller
should capable to provide all detail like Fail safe logic. ON/OFF sequencing. (Dedicated for each floor)
Digitally signed by ANUJ
Signature of Bidder Page 75 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
1.9 1.9 COPPER REFRIGERANT PIPING WITH INSULATION
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of
following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with
fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories,
insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular
sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per
specifications etc. as required :
Piping vaccumiazation and Nitrogen testing to be done by contractor and price for the same to be
Thickness of pipes should be as per VRF manufacturer's recommendation.
1.9.1 NSI 41.3 mm dia with 19mm thick insulation 10 Mtrs. 1,322.09 - 13,220.90 13,220.90
1.9.2 NSI 38.1 mm dia with 19mm thick insulation 10 Mtrs. 1,277.65 - 12,776.50 12,776.50
1.9.3 NSI 34.9 mm dia with 19mm thick insulation 90 Mtrs. 1,242.30 - 1,11,807.00 1,11,807.00
1.9.4 NSI 31.8 mm dia with 19mm thick insulation 10 Mtrs. 1,181.70 - 11,817.00 11,817.00
1.9.5 NSI 28.6 mm dia with 19mm thick insulation 700 Mtrs. 1,119.08 - 7,83,356.00 7,83,356.00
1.9.6 NSI 25.4 mm dia with 19mm thick insulation 30 Mtrs. 1,032.22 - 30,966.60 30,966.60
1.9.7 NSI 22.2 mm dia with 19mm thick insulation 150 Mtrs. 873.65 - 1,31,047.50 1,31,047.50
1.9.8 NSI 19.1 mm dia with 13mm thick insulation 280 Mtrs. 714.07 - 1,99,939.60 1,99,939.60
1.9.9 NSI 15.9 mm dia with 13mm thick insulation 430 Mtrs. 593.88 - 2,55,368.40 2,55,368.40
1.9.10 NSI 12.7 mm dia with 13mm thick insulation 700 Mtrs. 470.66 - 3,29,462.00 3,29,462.00
1.9.11 NSI 9.5 mm dia with 13mm thick insulation 180 Mtrs. 334.31 - 60,175.80 60,175.80
1.9.12 NSI 6.4 mm dia with 13mm thick insulation 390 Mtrs. 247.45 - 96,505.50 96,505.50
1.10 1.10 DRAIN PIPING
Providing & fixing of heavy duty uPVC Pipe complete with fittings, supports as per specifications and
duly insulated with 9mm thickness of closed cell tubular nitrile rubber as required & as per specifications.
Drain pipe pressure rating should be 10kg/m2
1.10.1 NSI 50 mm dia with 9 mm thick insulation 100 Mtrs. 188.87 - 18,887.00 18,887.00
1.10.2 NSI 40 mm dia with 9 mm thick insulation 220 Mtrs. 150.49 - 33,107.80 33,107.80
1.10.3 NSI 32 mm dia with 9 mm thick insulation 400 Mtrs. 132.31 - 52,924.00 52,924.00
1.10.4 NSI 25 mm dia with 9 mm thick insulation 240 Mtrs. 113.12 - 27,148.80 27,148.80
1.10.5 NSI 20 mm dia with 9 mm thick insulation 150 Mtrs. 105.04 - 15,756.00 15,756.00
1.11 1.11 CONTROL CABLE
Providing and fixing of suitable size of armoured copper control cable required for IDU to ODU
connection complete in all respect & as required.Size of cable as per Manufacturer recommedation.
Providing and fixing of control cable of 3 Core x 1.5 sqmm. shielded copper cable in Heavy duty PVC
conduit (20mm dia.) complete in all respect & as required.
Providing and fixing of control cable of 8 Core x 0.75 sqmm. shielded copper cable in Heavy duty PVC
conduit (20mm dia.) complete in all respect & as required.
Providing and fixing of control cable of 2 Core x 1.5 sqmm. shielded copper cable in Heavy duty PVC
conduit (20mm dia.) complete in all respect & as required.
1.12 1.12 VARIABLE FREQUENCY DRIVES FOR FM AHU & HRW UNIT
Supply of following HVAC dedicated VFDs with IP-20 enclosures, complying with the tender
specifications and having:
1. Without any active harmonic filters and accessories, required to limit THDI & THDV to 40%.
2. built-in EMC Filters (electromagnetic compatibility filters) for for VFDs for restriction of conducted
emissions to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 2,
3. Two feedback PID controller having capability to simultaneously accept 2/3 feedback signals from
temperature sensors or pressure sensors or CO2 sensors for process optimization and accordingly
regulate the speed of the AHUs.
Digitally signed by ANUJ
Signature of Bidder Page 76 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
4. Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy
5. MODBUS RTU / BACNET as the communication protocol between BMS & VFDs.
The complete integration of the VFD with AHU and duct static pressure sensor & integrator is included in
this item for process optimization and accordingly regulate the speed of the AHUs/ fan section. The VFD
will get signal from static pressure sensor & integrator located in the supply duct to modulate the supply
fan to control duct static pressure. On a call for full pressure, the fan runs at full speed. As duct static
pressure increases, the supply fan speed reduces.
1.13 1.13 DUCT PRESSURE SENSORS WITH INTERGRATOR
Supply, fixing, testing and commissioning of Duct mounted static pressure sensor located in the main
ducts. Pressure range shall be 0 to 75mm WC.Sensor should be complete in all respect and should be
capable to provide signal to VFD for varying the speed of fan. Integrator to allow complete integration
with Duct pressure sensor. The quoted price shall be inclusive of necessary conduting, copper control
cabling from the AHU room/ fan section to the sensor/integrator & all accessories as required. The
integrator shall be installed in AHU room/ near fan section. The integrator shall be capable to integrate
VFD . VFD shall be controlled with input signal received from duct pressure sensor. Integrator shall be
BMS compatible.
1.14 1.14 DUCT TEMPERATURE SENSORS
Supply, installation, testing and commissioning of duct mounted type Temperature Sensors S/A or R/A
complete as per requirement
1.15 1.15 DUCT MOUNTED UVGI SYSTEM
Supply, Installation, Testing and Commissioning of Ultra Violet Germicidal Irradiations, (UVGI) System to
be installed inside the Duct for Improvement of Indoor Air Quality as per Specifications. The Average Life
of UV lamps Shall be 12000 hrs.
The UVGI System shall consist of UV lamps with its mounting assembly and control panel. The Control
Panel shall be mounted outside the duct and should Consist of ballast, hour meter, MCB (or disconnect
switch), Indicating Light. The Prices to include inter connected wiring (UV resistant) between the UVGI
lamps and its panel.
UV lamp shall be fabricated out of special high transmission Quartz Glass and of the high output, hot
cathode, T5 (15mm) diameter and They shall produce 95% of their energy at 254 nm. UV lamp shall not
produce ozone or other secondary contamination and to substantiate this the lamps shall be tested by an
approved Indian lab for output performance of 254 nm. Lamp manufacturer to submit the certificate from
this lab. The lamp shall be high output type and should not be lower than 800 mA. The UV intensity of
each lamp shall be 800µW/cm² when measured at a horizontal distance of 10 inches from the lamp. Any
company offering to supply Ultraviolet Germicidal Irradiation (UVGI) System must have a minimum
experience of 50 months in supplying and implementing installations meeting these specifications.
The ballast shall only be installed in a control panel and shall be UL Listed also not inside the reflector
assembly itself. The system shall also include prices for spare lamps for one replacement after 12000
hrs. of initial supply. The number of lamps in an UVGI System shall be calculated to ensure the minimum
wattage as per selection chart based on 4016 microwatt. sec /cm2 dosage over 4 air changes.
The HVAC contactor shall submit the Duct size with CFM for Duct mounted application. The length of
straight duct should be provided by the HVAC Contractor at site.
Digitally signed by ANUJ
Signature of Bidder Page 77 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
1.16 1.16 AIR PURIFICATION SYSTEM FOR VRF IDU
Supply, Installation, Testing and commissioning of comprehensive Air Purification system , so as to
improve Indoor air quality by using combination of Needle point , Tube Type & Carbon Brush Type Bi-
polar Ionization technology, which produces a natural Bio Climate rich in positive and negative ions.
The Needle Point and Carbon Brush type Bipolar Ionizers should not have any consumables and should
have a life of 10 years. Project design should meet standard ASHRAE 62.1 IAQ Procedure for energy
saving. System should kill microorganism and pathogens, remove Odour, VOC and reduce dust particle
/particulate matter / PM2.5 /PM 10. The product should be UL / Intertek listed. Product should have
minimal or negligible pressure drop & low power consumptions. Product should have UL 867 and UL
2998 certification (for zero ozone emission). The Product shall have been Tested on COVID-19
Surrogate for its efficiency
VRF 4-WAY CASSETTE UNITS
VRF 1-WAY CASSETTE UNITS
VRF HI-WALLUNITS
1.17 1.17 HEAT RECOVERY UNIT-FOR FRESH AIR & EXHAUST AIR
Supply, Installation, Testing and commissioning of factory built floor mounted double skin type horizontal
air handling unit (two tier) made of panels consisting of pre coated G.I. casing of 0.8mm outside layer and
0.8 mm inside layer with polyurethane foam (PUF) with thermal break profile insulation and 38 kg/cum
density injected between them, complete with DIDW backward curve SA and RA blower section with
blower suitable for static pressure, filter section with 50mm thick washable synthetic type air prefilters
(MERV-8) in both supply air & return air path, Super fine filter (MERV-14) in supply air path only, belt
drive package with TEFC drive motor (IE-3) with IP-54/55 protection suitable for VFD operation at 415 ±
10% volts, 50Hz, 3 Phase AC supply, Heat recovery section with Heat Recovery Wheel as described
below,drain connections with drain valve, insulated stainless steel drain pan, fire rated flexible inside unit,
necessary vibration isolation arrangement, gravity louvers etc, complete as per specifications of following
capacities. Suitable capacity of TPN isolators for unit within MS enclosure to be provided.
The Heat Recovery wheel should have equal efficiencies both sensible & Latent greater than 70%. The
desiccant of the wheel should be Molecular Sieve 3 Angstrom to avoid any sort of cross contamination
between the two air streams. The Pressure drop across the HRW shall not be more than 20mm.
Heat recovery wheel shall be designed for ambient temperature of:
Summer -DBT 106.34 °F & WBT 74.84 °F
Monsoon-DBT 92.5 °F & WBT 83.3 °F
Winter-DBT 45 °F & WBT 41 °F
The return air temperature of air stream will be DBT 27°C respectively & RH 60%.
Supply air : 9500 CFM with 35mmwg External static pressure
1.17.1 NSI Exhaust air : 6825 CFM with 25mmwg static pressure 1.00 Nos. 8,95,153.91 - 8,95,153.91 8,95,153.91
1.18 1.18 SPLIT UNITS WITH INVERTER TECHNOLOGY
Digitally signed by ANUJ
Signature of Bidder Page 78 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, Installation, testing and commissioning of following capacity Hi wall type split air-conditioning
unit suitable to operate between 180-260 volt, 50 Hz, 1 phase power supply, with air-cooled evaporator
with coil, fan, and fan motor, air-cooled condenser with hermetically sealed rotary/ scroll compressor(with
green refrigerant gas), condenser coil, propeller fans controls, Necessary supporting arrangement for
indoor unit, M.S. frame duly Powder Coated/ Epoxy painted as per approved shade by architect to locate
Outdoor Unit with necessary vibration isolation arrangement as per site condition etc. The Unit should be
at least 3 Star rated (on the date of procurements, the minimum EER value of the units should be as per
ECBC-2017). The Refrigerant pipe size and gas quantity should suit to the copper pipe length at actual.
The capacity guarantee should be ensured by the manufacturer. The unit shall be complete with prefilters
section, control panel, with suitable rating of MCB/DP. Note:- Control and power cable will be priced
separatley with refrigerant piping item.
Civil Work such as wall hole making , wall chisling ,refilling of chiseling part with mortar etc as per site
The Outdoor unit Compressor must be provided with 5 Year Warranty Period.
1.19 1.19 DUCTABLE SPLIT UNIT WITH INVERTER TECHNOLOGY
Supply, Installation, testing and commissioning of following capacity Ductable split air-conditioning unit
suitable to operate from 415+10% volt, 50 Hz, 3 phase power supply, with air-cooled evaporator with coil,
fan, and fan motor, air-cooled condenser with suitable scroll compressors (with green refrigerant gas)
including first charges of gas, condenser coil, propeller fans controls, Compressor should be protected
with inbuilt thermal protector, internal pressure reflief valve, high pressure cutout & low pressure cutout.
Refrigerant pipe size and gas quantity should suit to the copper pipe length at actual. Necessary
supporting arrangement for indoor unit, M.S. frame duly Powder Coated/ Epoxy painted as per approved
shade by architect to locate Outdoor Unit with necessary vibration isolation arrangement as per site
condition etc.The capacity guarantee should be ensured by the vendor. The minimum EER value of the
units should be as per ECBC-2017. The unit shall be complete with prefilters section, fire retardent
canvass connection for duct connection, control panel, suitable rating of Isolator/MCB/MCCB with
weather proof enclosure. Note:- Control and power cable will be priced separatley with refrigerant piping
Civil Work such as wall hole making , wall chisling ,refilling of chiseling part with mortar etc as per site
The Outdoor unit Compressor must be provided with 5 Year Warranty Period.
1.19.1 NSI 5.5 TR-For Data Centre
1.19.2 NSI Corded Remote with control wiring (Approx. 10mtr.) with conduit for ductable split unit 3.00 Nos. 72,064.51 - 2,16,193.53 2,16,193.53
Supply, Installation, Testing and Commissioning of Auto Sequencing timer controller and Alarm system in
case of fault & failure of any Split unit, automatically start the other unit, complete with
enclosure/accessories having facility for configuration of the same as per requirement for sequenced
Start/Stop for Central control room’s units (dedicated for each room).
1.20.1 NSI For two numbers of split units (1W+1S) 3.00 Sets 4,146.05 - 12,438.15 12,438.15
1.20.2 NSI For three numbers of split units (2W+1S) 3.00 Sets 4,146.05 - 12,438.15 12,438.15
Providing and fixing of copper soft refrigerant piping (Circuit length) along with power & control cabling
1.21 1.21 and earthing. The pipe shall be insulated with 13mm thick closed cell electrometric nitrile rubber tubular
Providing and fixing of Pair of insulated Hard copper refrigerant piping along with power & control cabling
and earthing for 5.5 TR Ductable type split unit. Price shall be inclusive of all fittings (elbows, bends,
reducers etc.) along with required size of control cable, power cable & slotted angle tray. The pipe shall
be insulated with 13mm thick closed cell electrometric nitrile rubber tubular insulation.
Digitally signed by ANUJ
Signature of Bidder Page 79 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
2 2 HVAC WORKS - VENTILATION SUBHEAD-2
2.1 2.1 AMCA CERTIFIED AXIAL FAN FOR FRESH AIR
Supplying, installation, testing and commissioning of AMCA Certified , long cased single pieced ceiling
hang / floor mounted axial flow type Supply air fan of suitable capacity with powder coated MS/ GSS
casing and aluminium alloy impellers with high efficiency aero‐foil sections, blades, the impeller directly
driven by TEFC induction motor of high efficiency class IE2 (with IP55 protection) suitable for 3 Phase 50
Hz 415V ± 10 %. Motor for supply air fans shall have class 'F' insulation as required and as per
specifications. Fan total efficiency should not be less than 60%. Motors shall be pre-wired to an external
electrical terminal box through weatherproof flexible conduit/ vanes/tube.
Sound level for fan shall not exceed more than 80dB(A) at 3meter distance at both ends when measured
in hemispherical reverberant room conditions. Max. Outlet velocity should not more than 3000FPM.
Fan should be complete with all accessories including vibration isolators, mounting brackets, nut, bolts,
bird screen etc. as required and as per specifications. Suitable capacity of TP isolator within MS
enclosure for AHU to be provided.
2.1.1 NSI 19000 CFM/ 30mm WC External static pressure 2 Nos 57318.51 - 1,14,637.02 1,14,637.02
2.1.2 NSI 13000 CFM/ 25 mm WC External static pressure-Lift Lobby pressurization 2 Nos 44287.49 - 88,574.98 88,574.98
2.1.3 NSI 6500 CFM/ 20 mm WC External static pressure-Lift well pressurization 3 Nos 28864.79 - 86,594.37 86,594.37
2.1.4 NSI 20500 CFM/ 25 mm WC External static pressure-Staircase pressurization 1 Nos 61715.04 - 61,715.04 61,715.04
2.2 2.2 AMCA CERTIFIED AXIAL FAN FOR EXHAUST AIR
Supplying, installation, testing and commissioning of AMCA Certified, long cased single pieced ceiling
hang / floor mounted axial flow type Exhaust air fan of suitable capacity with powder coated MS/ GSS
casing and aluminium alloy impellers with high efficiency aero‐foil sections, blades, the impeller directly
driven by TEFC induction motor of high efficiency class IE2 (with IP55 protection) suitable for 3 Phase 50
Hz 415V ± 10 %. Motor for Exhaust air fans shall have class 'H' insulation as required and as per
specifications. Fan total efficiency should not be less than 75%. Motors shall be pre-wired to an external
electrical terminal box through weatherproof flexible conduit/ vanes/tube.
The exhaust air fan shall be rated for a minimum of 250 Deg C for a minimum of 2 hours application as
per EN 12101:3-2015, every model shall be mention in test report, make of motor shall be same as per
Sound level for fan shall not exceed more than 80dB(A) at three meter distance at both ends when
measured in hemispherical reverberant room conditions. Max. Outlet velocity should not more than
Fan should be complete with all accessories including vibration isolators, mounting brackets, nut, bolts,
bird screen etc. as required and as per specifications. Suitable capacity of TP isolator within MS
enclosure for AHU to be provided.
2.2.1 NSI 9000 CFM/ 30 mm WC External static pressure 2 Nos 41089.83 - 82,179.66 82,179.66
2.2.2 NSI 6500 CFM/ 30 mm WC External static pressure 4 Nos 35813.59 - 1,43,254.36 1,43,254.36
2.3 2.3 INLINE FAN
Supply, installation, testing and commissioning of circular/ rectangular Inline fan for exhaust air with
centrifugal blower and motor encased in sheet metal casing, as per specifications. The motor shall be
suitable for 220 voltage, 1 phase, 50 cycle AC cycle. All accessories including 6/16 Amp plug complete
with wiring between the fan and the socket to be provided as required and as per specification.The noise
level of selected fan should not more than 50dba @ 3mtr.
2.3.1 NSI 300 CFM, 8mm Static Pressure 4 Nos 4,636.91 - 18,547.64 18,547.64
2.3.2 NSI 650 CFM, 12mm Static Pressure 1 Nos 6,795.28 - 6,795.28 6,795.28
2.3.3 NSI 1550 CFM, 15mm Static Pressure-Rectangular Cabinet type with internal acoustic lining 1 Nos 14,589.45 - 14,589.45 14,589.45
2.4 2.4 PROPELLER FAN (Platsic Body- Low noise)
Digitally signed by ANUJ
Signature of Bidder Page 80 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supplying, installation, testing & commissioning of Propeller type fans for following capacities complete
with electric motor suitable for operation on 220 V ± 10%,50 Hz, 1 phase AC supply fitted with NRD, 6/16
Amp plug and wiring between the fan and the socke, mountings, frames, louvers and bird screen etc.
3 3 HVAC WORKS - AIR DISTRIBUTION SUBHEAD-3
3.1 3.1 Factory Fabricated GSS Duct
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal
rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,
hangers, supports etc. as per approved shop drawings and specifications of following sheet thickness
complete as required.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal
rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers,
vanes, hangers, supports etc. as per approved shop drawings and specifications of following
sheet thickness complete as required.
3.3 3.3 AIR DISTRIBUTION
Supply, installation, testing and commissioning of GI volume control duct damper complete with
neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control
dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air/Exhaust Air Grills with louvers but
without volume control dampers complete as required.
Supplying & fixing of powder coated extruded aluminium Supply Air Removable core Grills with
aluminium volume control dampers as per specifications.
Supply, installation, testing of extruded aluminium powder coated linear grill without volume control
damper as per drawings.
Supply, Installation and Testing of collar damper of galvanised steel sheet, provided with suitable links,
3.3.6 NSI levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution 15.00 SQM. 2,078.58 - 31,178.70 31,178.70
as per approved shop floor drawings and specifications.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with
aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without
volume control dampers with anti smudge ring & removable core.
Supply, fixing and commissioning of Fresh/ exhaust air louvers with section comprising of powder coated
Aluminium louvers & bird screen as required.
Supply, fixing and commissioning of powder coated extruded aluminium Door Transfer Grill complete
with nuts, bolts, SS screws etc. complete as required.
Digitally signed by ANUJ
Signature of Bidder Page 81 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air
path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring
return so as to close the damper in the event of power failure automatically and open the same in case of
power being restored. The spring return action shall be inbuilt mechanism and not externally mounted.
The damper shall also be closed in the event of fire signal complete as required and as per
specifications.
3.4 3.4 PREINSULATED FLEXIBLE DUCTING
Supplying and fixing of the round flexible duct inner core should be made of double lamination of
Aluminum Foil, Polyester & Metalized polyester film permanently bonded to a coated spring steel wire
helix. Fiberglass insulation shall be of 25mm thick with minimum density of 16 kg/m³. The outer
insulation jacket vapor barrier shall be made of fiber glass reinforced metalized polyester film laminated
with aluminum foil. Both the end connections shall be through double 'O' rings.
3.5 3.5 SPIGOTS
Supply, Installation and Testing of single piece GI round spigot made out of spinning process with
50mm height and having grooves on both sides and circular flanges. Spigots shall be installed on main
ducts to facilitate connection of flexible ducts.
3.6 3.6 DEMAND CONTROL VENTILATION SYSTEM
Supply, installation, Testing & Commissioning of complete (VAQ) demand control ventilation system for
fresh air, heavy gauge extruded aluminium of 1.5 mm nominal thickness complete with Zero leakage
(aerofoil construction) extruded aluminium profile volume control damper, Rapid Average Pitot tube; Air
Flow Straightner (Honey-comb Patterned) with Motorized Assembly for Dampers with programmable
single space DCV Controller combined with integrator; differential pressure sensor; & step down
transformer of 24V.IVAQ sytem shall communicate through modbus/any open protocol provide signal to
VSD of air handle/ fan sectionr unit. The system should complete in all respect including conrol
panel/integrator, CO2 sensor, thermostat, actuator, all wiring,conduiting between sensor, actuator,
thermostat and to connect with VSD shall be included, in the package.
3.6.1 NSI Bare dampers in extruded aluminium construction. 1.5 SQM. 11,991.73 - 17,987.60 17,987.60
Actuator with control panel, necessary sensors and spring return action and suitable for 10 NM Torque.
3.6.3 NSI CO2 Sensor for fresh air modulation. 7 Nos. 15,988.30 - 1,11,918.10 1,11,918.10
3.6.4 NSI Control panel / Integrator 1 Nos. 67,950.78 - 67,950.78 67,950.78
3.6.5 NSI Control & Powe Cable, 2C X 1.5 sqmm shielded skined Cu cable for DDC Controller Signal. 150 Rmt 113.12 - 16,968.00 16,968.00
3.6.6 NSI Control & Power Cable, 3C X 1.5 sqmm Cu Cable For DDC Power. 350 Rmt 138.37 - 48,429.50 48,429.50
3.6.7 NSI Cat 5/6 cable for connection between Co2 sensor and controller 500 Rmt 33.33 - 16,665.00 16,665.00
Supply and Installation of 2Hr. Fire Resistant Fabric Flexible Connection to be installed between all the
Fans and the ducting to provide flexibility of movement in case of a seismic event and to prevent
transmission of vibration from the unit to the duct. The fabric should be min. 2Hr. fire resistant, fiberglass
weave with silicone rubber coating with Galvanized metal strip as per specifications. Flexible duct
connector fabric shall be air tight, waterproof, virtually chemically inert and shall not emit toxic fumes
when exposed to open flame. The flexible canvas connector shall be tested and certified in accordance
with BS 476 Part 7 Class 1 and NFPA 701 from NABL accredited laboratory.Flexible Canvas material
shall be provided with factory fitted GI flanges on both sides (as per requirement).
Digitally signed by ANUJ
Signature of Bidder Page 82 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (HVAC WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supply, installation & testing of GI back draught dampers similar construction of gravity louvers
3.8 NSI provided with suitable links to prevent the back pressure of air.Back draft damper to be provided at the 2 SQM 4,636.91 - 9,273.82 9,273.82
discharge side of the fan.
4 4 HVAC WORKS - INSULATION SUBHEAD-4
4.1 4.1 DUCT INSULATION
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile
rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints
shall be sealed with 50 mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as
per specifications and as required. Insulation as per CPWD-2017 specification.
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass
wool having density of 32kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600mm centre to
4.2 16.21 centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to 150 SQM. 653.47 98,020.50 - 98,020.50
inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as
required and as per specifications.
4.3 4.3 ACOUSTIC INSULATION FOR AHU ROOM
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m
resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of
4.3.1 16.22 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced 480 SQM. 1,150.39 5,52,187.20 - 5,52,187.20
fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and
as per specifications.
5 5 HVAC WORKS -WATER PURIFIER CUM WATER COOLER SUBHEAD-5
5.1.1 NSI SITC of Water Cooler 150/150 Ltrs with 150 ltrs cooling capacity (3-4 faucets) are required. 4.00 No. 55,449.00 - 2,21,796.00 2,21,796.00
SITC of UV+UF (Optional) Water purifier with 6 stage 15-20LPH ouflow capacity and 8-10 Ltrs storage
tanks including water sensor completeas required.
Digitally signed by ANUJ
Signature of Bidder Page 83 of 90 GULIA Signature of NBCC
NBCC (INDIA) LIMITED
(A Govt.of India Navratna CPSE)
NAME OF THE WORK :-CONSTRUCTION OF BALANCE WORKS OF MEHTA FAMILY SCHOOL OF DATA SCIENCE AND
ARTIFICIAL INTELLIGENCE (MFSDSAI) INCLUDING INTERNAL EL, HVAC, FIREFIGHTING, FIRE ALARM, LIFTS, AUDIO
VISUAL SYSTEM, CCTV AND BMS INSTALLATION AND DEVELOPMENT WORKS AT I IT ROORKEE, UTTARAKHAND
NAME OF CLIENT :- IIT ROORKEE
NAME OF THE BIDDER :-
SUMMARY SHEET- FIRE FIGHTING AND FIRE ALARM WORKS WORKS
SI. NO DESCRIPTION OF ITEM
DSR N.S.I. Total
1 FIRE FIGHTING WORKS - SUBHEAD-1 ₹ 7,50,955.20 ₹ 5,50,700.48 ₹ 13,01,655.68
Signature of Bidder Page No 84 of 90 Signature
Digitally signed of
NBCC (INDIA) LIMITED
NAME OF THE WORK :-CONSTRUCTION OF BALANCE WORKS OF MEHTA FAMILY SCHOOL OF DATA SCIENCE AND ARTIFICIAL INTELLIGENCE (MFSDSAI) INCLUDING INTERNAL EL, HVAC,
FIREFIGHTING, FIRE ALARM, LIFTS, AUDIO VISUAL SYSTEM, CCTV AND BMS INSTALLATION AND DEVELOPMENT WORKS AT I IT ROORKEE, UTTARAKHAND
SCHEDULE OF QUANTITIES (FIRE FIGHTING AND FIRE ALARM WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
1 1 FIRE FIGHTING WORKS - SUBHEAD-1
1.1 1.1 PUMPS
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic
1.1.1 1.1.1 operation and consisting of following, complete in all respects, as required: (Terrace Pump)
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless
steel shaft, mechanical confirming to IS : 1520
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz,
AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F'
insulation, conforming to IS-325.
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
1.2 1.2 System Controller System
Designing, Supply, Installation, Testing and Commissioning of system controller to control operation of
1.2.1 1.2.1 Terrace Fire Pumps in sequence as per specification consisting of relays, timers, sensors, annunciation
window for fault indication, complete as per specification.
First Terrace pump will start and in case for failure another stand by pump will start.
Colour coded internal wiring and connections etc. with suitable size Fire Retardant Low Smoke PVC
insulated copper cable / solid aluminium strip / bus bar from incoming to bus bar and from bus bar to
switch gears / MCCB, starters, meters, selector switches, indicating LED's, interlocking and sequence
operation arrangements.
1.2.1 NSI System Controller Panel for terrace pump 1.00 Set 23,882.46 - 23,882.46 23,882.46
1.3 1.3 PIPING, VALVES AND ACCESSORIES
SLTC of M.S. pipe on surface
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat
duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as
Digitally signed by ANUJ
Signature of Bidder Page 85 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (FIRE FIGHTING AND FIRE ALARM WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of
required size to be fitted between flange & landing valve of external and internal hydrants to reduce
pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type
Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 .
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm
thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:
5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
1.4 1.4 HYDRANTS SYSTEM
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel
1.4.1 1.4.1 coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank
Gunmetal/Stainless Steel cap and chain as required :
1.4.1.1 9.2 Single headed Stainless steel 10.00 Each 6,046.87 60,468.70 - 60,468.70
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly
bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size
nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming
1.4.4 1.4.4 to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic
(Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve &
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal
valve & M.S. Pipe and socket.
1.4.5 1.4.5 SITC weather proof M.S Door and glass fire door size 2100 mm x 900 mm or as per arch.
Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 2100
mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with
glass, locking arrangements to accommodate the following: -
Digitally signed by ANUJ
Signature of Bidder Page 86 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (FIRE FIGHTING AND FIRE ALARM WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
a) Gunmetal single headed Hydrant valve - 1 No.
b) Fire Hoses 63mm, 15 M long with accessories - 2 Nos.
c) Short branch - 1 No.
d) First Aid hose Reel - 1 No.
f) Fireman's Axe - 1 No.
g) Pressure Gauge - 1 No.
The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved
Digitally signed by ANUJ
Signature of Bidder Page 87 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (FIRE FIGHTING AND FIRE ALARM WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet
couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air
release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel
valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved
shade as required.
1.5 1.5 FIRE EXTINGUISHERS
Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel
cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type
valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non
conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed.
1.5.1.2 NSI ABC type extinguisher with cylinder fully charged with 6 Kg. capacity. 20.00 Each 2224.02 - 44,480.40 44,480.40
2 2 FIRE ALARM WORKS - SUBHEAD-2
2.1 2.1 FIRE ALARM SYSTEM
Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main
fire alarm panel, central processing unit with the following loop modules and capable of supporting not less
than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km,
network communication card, minimum 320 character graphics/ LCD display with touch screen or other
keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230
2.1.1 17.2.1 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The
panel shall have facility to connect printer to printout log and facility to have seamless integration with
analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and
shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol
BACnet/ Modbus over IP complete as per specifications.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD
display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable Photothermal Detector
2.1.3 17.2.4 detector complete with mounting base complete as required. 441.00 Nos. 2886.58 12,72,981.78 - 12,72,981.78
Supplying, installation, testing & commissioning of intelligent addressable Thermal/Heat Detector with rate
of rise cum fixed tempreature thermistor complete with base as required.
2.1.5 17.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 13 Nos. 3909.71 50,826.23 - 50,826.23
2.1.6 17.2.15 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 13 Nos. 3541.06 46,033.78 - 46,033.78
Digitally signed by ANUJ
Signature of Bidder Page 88 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (FIRE FIGHTING AND FIRE ALARM WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
2.1.7 17.2.19 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. 13 Nos. 1616.00 21,008.00 - 21,008.00
2.1.8 17.2.17 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. 1.00 Nos. 5797.40 5,797.40 - 5,797.40
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
(For AHU, Ventilation and pressurization fans )
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having
two LED, metallic cover complete with all connections etc as required.
2.1.11 17.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 25.00 Nos. 3302.70 82,567.50 - 82,567.50
2.1.12 NSI Supplying, installation, testing & commissioning of addressable fire Monitor module complete as required. 4.00 Nos. 2692.66 - 10,770.64 10,770.64
Supplying, installation, testing & commissioning of Exit Sign and Internal Hydrant illuminated Sign with 90
min. battery back up
PUBLIC ADDRESSABLE SYSTEM
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player
2.1.14 17.3.1 (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for 1.00 Set 127675.11 1,27,675.11 - 1,27,675.11
voice evacuation complete as required
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone
assembly complete as required
2.1.16 17.3.2 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required 187.00 Nos. 974.65 1,82,259.55 - 1,82,259.55
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at
240 Volt AC Supply complete as required
CONDUITS AND CABLES
Supplying & laying of 2x1.5 sqmm fire survival armoured/unarmoured cable, 600/1000V rated with
annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross
Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring &
LSZH outer sheath complete as required
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing
2.1.19 17.5.3 surface / recessed steel conduit of following pairs, cores and size including connections and
interconnections etc. as required
2.1.19.1 17.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm 2200 Meter 54.54 1,19,988.00 - 1,19,988.00
Digitally signed by ANUJ
Signature of Bidder Page 89 of 90 GULIA Signature of NBCC
SCHEDULE OF QUANTITIES (FIRE FIGHTING AND FIRE ALARM WORKS)
CPWD Rate Rate Amount Amount Total Amount
CPWD Rate Rate Amount Amount Total Amount
S.No. Description of Item Quantity Unit
DSR 2018 DSR Non-DSR DSR Non-DSR DSR + Non-DSR
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including
2.1.20 1.20 painting in case of surface conduit, or cutting the wall and making good the same in case of recessed
conduit as required.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and
accessories like coupler etc. as required.
Digitally signed by ANUJ
Signature of Bidder Page 90 of 90 GULIA Signature of NBCC
aoc.pdf