Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹43.5 L+₹61,294 (1.43%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹46.6 L+₹3.6 L (8.48%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L3 | Rejected-Finance Being L3 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
21 Oct 2024, 6:00 pmClosed
GE I CG PORBANDAR
GE I CG PORBANDAR DHQ 1 OPPOSITE BIRLA FACTORY PORBANDAR
REPAIR MAINT OF HT LT INTERNAL EXTERNAL ELECTRIC SUPPLY MAINT TO LT APFC PANELS STREET LIGHTS POLES GARDEN LIGHTS MAINT TO EXTERNAL WATER SUPPLY PIPE LINES MAINT OF PUMP MOTOR STP DG SETS COOLING APPLIANCE MISC ITEMS AT ICGS VERAVAL
2024_MES_675418_1
8004A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
VERAVAL
As per NIT
9 documents required · 9 mandatory
₹500
GE I CG PORBANDAR
₹94,000
Yes
30 Nov 2024
19 Sept 2024
23 Oct 2024
19 Sept 2024
21 Oct 2024
4 Oct 2024
Amount
SCHEDULE 'A' E/M
Material and labour for painting of the tranformer 100 KVA to 400 KVA, RMU, VCB and CSS Body complete by removing old paint by scrapping and providing spray painting with epoxy paint of approved (suitable for existing colour) make duly marking/writing MES/SM No., Complete all as specified and directed by Engineer-in-Charge.
Taking out UNSV HT UG cables of any sizes from trenches, Complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, connecting, testing and commissioning and jointing of HT underground cable of size 95 Sqmm 3 core, 11000 volts grade, XLPE insulated screened PVC bedded, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/ path/drain/ culverts or encased in GI pipe fixed & testing and commissioning, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Indoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of air break switch triple pole, 11KV, mechanically operated mounted on insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 400 Amps complete with including insulators horizontal /vertical rod and operating pipe of suitable size and length, jumper connections and reconnecting of suitable size and length and making connection to new AB switch gang operated, Complete all as specified and directed by Engineer-in-Charge.
Preventive Maintenance and Servicing, 11/0.433 KV Step down Transformer Indoor and Oil Cooled type by disconnecting carefully electric connection on primary & secondary side, Checking both side HT bushing, bushing rod, opening top cover of the transformer by unscrewing nuts, bolts, washers etc, rectify the oil leakages issues, if noticed any from the entire body of the transformer, during servicing and re-fixing the top cover of transformer according to previous system. Servicing of the transformer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each transformer to the Engr-in-Charge. Note 1. :- Inspection of transformer shall involve :- (a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc. (b) Checking all brazings, joints, tap heads, gaskets and connection joints. (c) Checking all terminations / connections inside/ouside the transformer. (d) Checking of off load tap changer assembly, checking the moving and fixed contacts for contact wear and connection to winding. (e) Conducting the test on core and windings as per IS like ratio, magnetic imbalance, short circuit, IR Value, High Voltage Test etc. in presence of Engr-in-Charge. Note 2. : Spares used bushes studs HT/LT, bushing rod HT/LT, transformer oil, filteration of oil, buchholtz relay, Gaskets set, Off Load Change over switch etc will be measured and paid separately under respective item of BOQ. Note 3 :- The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement.
100 to 400 KVA
Material & Labour for Dehydration/Filteration of tranformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement, Complete all as specified and directed by Engineer-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Supply & fixing in replacement of Silica Gel (Moisture absorbent chemical ) for breather of transformer 11 KV /433 Volt of any make / rating, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of oil temperature indicator gauge suitble for transformer of capacity 11KV/433 Volt, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of LT bushings with brass studs complete washer with nuts bolts and washers of brass of suitable size for 250 KVA to 630 KVA transformer, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of HT bushing with brass studs complete washer with nuts bolts and washers of brass of suitable size for 250 KVA to 630 KVA transformer, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Maintenance/Over hauling of HT VCB 11 KV (1 No incoming, 1 Nos outgoing) by taking shunt down with prior intimation and cleaning of HT VCB by using air blower, tightning the control circuit, Checking the all fuses, to ensure the smooth functioning of HT VCB by employing the Skilled trades man and helper, Complete all as specified and directed by Engineer-in-Charge. Note: Rate Include following:- (i) Replacement of small piece of wire of sq area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of unseviceable indicator lamps as per colour code all as specified and as directed by Engineer - In - Charge. (ii) Rack out /Down the HT VCB kept in Test position , Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the serviceability of earthing connection by Earth megger note down the readings.
Supply & fixing in replacement of charging motor suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of closing coil 24Volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Tripping coil 24Volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of master Trip Relay 110 Volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Auxilary Relay 110 volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement of protection Relay (over short Circuit /earth fault) 110 volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of HT 11 KV drop out fuse assembly with insulator and base including fuse tube, fuse carrier top connectors incomming and out going connectors, Complete all as specified and directed by Engineer-in-Charge. (Note: Rate include taking down existing unserviceble/ Faulty DO fuse assembly and fix the new one and make the incomming and out going connections and switch on the supply through the new DO fuse assembly all as directed by EIC)
Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of connect lightening arrestor non linear, pole type 11 KV discharge capacity 65 KA, with all fittings suitable for 11 KV electric working pressure including strap, bolts, nuts and washers etc., Complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in hard/dense soil, Complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading levelling watering and well Ramming in layers not exc 25 cm thick, Complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exc 1.5 m above the starting point, Complete all as specified and directed by Engineer-in-Charge.
Laying only un-reinforced precast concrete cable cover class HV, type-I, flat size 300mmx 180mm x 40mm laid cable cover to be reused, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:2:4; including removal of surplase soil, Complete all as specified and directed by Engineer-in-Charge.
Comprehensive maintenance and repair of APFC panel by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, Complete all as specified and directed by Engineer-in-Charge. Note: Defective parts if any will be measured and paid seprately.
Supply & fixing in replacement of heavy duty gas filled Capacitor 5 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified and directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply & fixing in replacement of heavy duty gas filled Capacitor 10 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified and directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply & fixing in replacement of heavy duty gas filled Capacitor 20 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified and directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply & fixing in replacement of 6 Steps APFC Relay, microprocessor based and connected items, Complete all as specified and directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Material & Labour for apply two coat of epoxy paint on LT Panels of any size, including preparation of rusted surface of panel by means of sand paper/scrubing of dust etc and apply one coat of epoxy based primer before painting, Complete all as specified and directed by Engineer-in-Charge. Note: Minor repair/ replacement of hinges suitable for screw fastners and fixed in original position deemed to be included in unit rate.
Supply & fixing in replacement of Digital time switches (SST 15 min) for street light 215 V single Phase, Complete all as specified and directed by Engineer-in-Charge. Make :L&T/Havells
Material & Labour for preparation of old painted surfaces of Steel Tubular pole upto 9 Mtr long by scarping old paint and applying Single coat of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and Blue stripes each 30 cm (5 Strips) apart up to 1.5 Mtr height and including one coat white distempering for pole foundation above ground level shall deemed to be included in the quoted rate etc., Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor, Complete all as specified and directed by Engineer-in-Charge. Cable Joint of following sizes:-
25 Sqmm to 50 Sqmm
70 Sqmm to 120 Sqmm
150 Sqmm to 185 Sqmm
Taking out unserviceable LT UG cables of any sizes from trenches, Complete all as specified and directed by Engineer-in-Charge.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area, Complete all as specified and directed by Engineer-in-Charge. Cable of Following sizes:-
16 Sqmm 4 Core
25 Sqmm 4 Core
50 Sqmm 3.5 Core
95 Sqmm 3.5 Core
150 Sqmm 3.5 Core
185 Sqmm 3.5 Core
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories, including taking down old unservicable DWC pipe, Complete all as specified and directed by Engineer-in-Charge. Note: Cutting of floor/ road and making good with PCC deemed to be included in item rate. Make: Rex/Poly/Geminie DWC Pipe of Following sizes:-
Supply and fixing in replacement of MCB/MCCB FP, 415 V fixed type, including taking down of old unsv panel after disconnecting Existing cables and reconnecting the cabes with proper lugs and glands, Complete all as specified and directed by Engineer-in-Charge of following:-
MCCB 63/100 Amp FP, 415 V breaking capacity 27 KA
MCCB 200 Amp FP, 415 V breaking capacity 25 KA
MCCB 320 Amp FP, 415 V breaking capacity 36 KA
MCB 63 Amps FP, 415 V breaking capacity 10 KA
MCB 6 to 32 Amps SP, 240 V breaking capacity 10 KA
Dismantling and taking down the existing defective street light fitting of any type and any capacity LED street light from steel tubular pole, opening the street light fitting, checking the serviceability, remove the cable carbon and replacement of 3 Core 1.5 Sqmm size multistranded copper conductor including taking down old unsv 3 Core 1.5 Sqmm size copper conductor, Complete all as specified and directed by Engineer-in-Charge. Note:- 1.5 Sqmm 3 core size multistranded copper conductor etc will be measured and paid separately.
Supply & fixing in replacement of street light fitting LED type 70 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and including driver unit etc, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of LED flood Light fitting 150 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of of Multi standard Copper Conductor cable of size 1.5 Sqmm 3 Core, inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to street light fitting etc., Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement 4 pole power contactor MCX-13, 50 Hz, Complete all as specified and directed by Engineer-in-Charge. Make : L&T or equvalent
Supply & fixing in replacement power Relay MNX - A1,/MNX - A2, 50 Hz, Complete all as specified and directed by Engineer-in-Charge. Make : L&T or equvalent
Supply & fixing in replacement of Bldg Security light fitting LED type 25 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and including driver unit etc., Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of LED Bollard 11W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, 50 Hz, pole mounted, including PCC 1:2:4 type B1 (20mm graded aggregate) base of size 300mm x 300mm and depth 600mm for fixing of Bollard with nuts bolts etc required as per site, Complete all as specified and directed by Engineer-in-Charge. Note: Apply for single coat of suitable colour distempering for bollard foundation shall deemed to be included in the quoted rate.
Supply & fixing in replacement of LED Bollard 10W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, pole mounted, including PCC 1:2:4 type B-1 (20mm graded aggregate), base of size 300mm x 300mm and depth 500 mm for fixing of Bollard with nuts bolts etc required as per site, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of automatic street light switch (5 KW to 8 KW) Amps rating 20 Amps NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compound conforming to IP-54. The contactor, MCB and circuit wiring 16/10 Sqmm copper shall be suitable, Complete all as specified and directed by Engineer-in-Charge. Make :- Model No. SWADEEP-02EC-5KW, 3P (3 PHASE) of Healer or equivalent to Havells /L&T
Supply & fixing in replacement of On-Load Changeover Switch with encloser 200 Amps, 4 Pole, 415 Volt with cable entry, connecting the cables with proper lugs and glands, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Pole box with 6 Amps MCB provision and suitable connector for single hose connections loop in and out 10 to 16 Sqmm 4 core aluminium armoured cable branch out 1.5 Sqmm single core copper PVC insulated cable enclosed in a thermoplastic polycarbonate enclosure which should be shock proof safe IP 66/67 weather proof, rust proof, dust proof, water proof, internally embedded gasket with provision for cable entry through IP 66/67 thermoplastic metric size glands and/or grommets enclosure size (155 x 210 x 92mm ), fixing arrangement and clamps including making connections, Complete all as specified and directed by Engineer-in-Charge. (Cat Part No KF 1616 G of Make : Hensel or equivalent model of Sintex)
Supply & fixing in replacement of Aluminum lugs long barrel of size 185 Sqmm, Complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply & fixing in replacement of Aluminum lugs long barrel of size 150 Sqmm, Complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply & fixing in replacement of Aluminum lugs long barrel of size 120 Sqmm, Complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply & fixing in replacement of Aluminum lugs long barrel of size 95 Sqmm, Complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply & fixing in replacement of Aluminum lugs long barrel of size 70 Sqmm, Complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply & fixing in replacement of Aluminum lugs long barrel of size 50 Sqmm, Complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply & fixing in replacement of Aluminum lugs long barrel of size 25 Sqmm, Complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Material and Labour for painting the MS supporting structure of solar ON Grid power plant up to capacity 30KW, complete as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc., Complete all as specified and directed by Engineer-in-Charge. Location : Inaz Vig, OTM Complex.
Taking up/down CI/DI pipes with connection from trenches including connected fittings/accessories complete of 100mm bore size and removing the pipes and reused to site, Complete all as specified and directed by Engineer-in-Charge.
Taking up/down CI/DI pipes with connection from trenches including connected fittings/accessories complete of 80mm bore size and removing the pipes and reused to site, Complete all as specified and directed by Engineer-in-Charge.
Supply & laying of jointing in trenches DI pipes class K 7 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 100 mm dia ISI, Complete all as specified and directed by Engineer-in-Charge.
Supply & laying of jointing in trenches DI pipes class K 7 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 80mm dia ISI, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of size 50mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of size 25mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of size 50mm dia, PP-R Ball valves (brass insert) as per requirement of the site, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of size 25mm dia, PP-R Ball valves (brass insert) as per requirement of the site, Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of ISI marked ductile iron socketed fittings supplied as per IS: 9523/2000 of class K-12, PN-10 for pressurized water delivery with inside Cement Mortar lining and outside zinc followed by black bitumen coating for size 80mm dia to 150mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch, cross collars, caps and plug set including rubber ring push on joints, Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement rubber gasket (Tyton) joints suitable for 100mm bore CI/DI pipe and fittings including jointing material, Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement rubber gasket (Tyton) joints suitable for 80mm bore CI/DI pipe and fittings including jointing material, Complete all as specified and directed by Engineer-in-Charge.
Dismantling monoblock pump set centrifugal type of cap 20 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc and re-assembling the complete pump after repairs and replacement of parts as required, refixing the same at site including electric and piping connections complete, checking for satisfactory working, Complete all as specified and directed by Engineer-in-Charge. (Note : Cost of dismantling and refixing deemed to be included in quoted rate)
Pumping out sewage water from the existing sumps/tanks of STPs (MBBR technology) with the help of Non clogging of pump any kind capacity of pump set not less than 1500 LPM capacity 10HP/15 HP (Minimum) along with tanking out mud/ solid sludge from the tank complete from solid seperation chamber, aeration chamber and despose whole sludge to faraway areas from public places including cleaning of sump completely. So as to vacate the sumps to enable the repair of the main non clogging pump sets installed in the STPs, Complete all as specified and directed by Engineer-in-Charge. Location : CGRA Inaz Note :- (a) Pumping shall be continued till the main pumps installed in STPs sump is cleared for carrying out repair work. (b) Delivery pipe should be connected and the sewage water shall be thrown in the manhole of out side the fencing /wall of STPs towards the main gravity dropping main hole. (c) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative. (d) Necessary man power to operate the pump set are deemed to be included in the rate. (e) Rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set. (f) Rate included for transportation of pump set to site/back.
Material & Labour in PP floating media to top up for bio reactors, Complete all as specified and directed by Engineer-in-Charge.
Carry out water testing of bacterial, chemical and biological analysis of sewage water treated water from NABL accredited Govt approved lab for following parameters and submission of test reports, Complete all as specified and directed by Engineer-in-Charge. Location : CGRA Inaz (a) PH (b) Chemical Oxygen demand/COD (c) Biological Oxygen Demant/BOD (d) Total Suspended solids (e) Oil and grease (f) TKN (g) Total Coliform (h) Organism MPN (k) Dissolved Oxygen Note: Every Quarterly water testing shall be carried out as per CA Qty in period of contract all as directed without fail else recovery will be made at Rs 15000/- per test for execution of item and for non-submission of Test Report.
Water Testing, Collecting the sample of water at Pump house and testing of water for iron, PH value, TDS, colour, Total Hardness, chloride, Chlorine, fluoride, Coliform, arsinic test and submitting the test report from reputed laboratory, Complete all as specified and directed by Engineer-in-Charge. Location : CGRA Ianz
Supply only Sodium hypochloride Calcium based, high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed container (45/50 Kg 45 Kg container), chlorine concentration level 40-60% 65-70 % , Complete all as specified and directed by Engineer-in-Charge. Make Rayalseema, Brand Puri chlor
Supply only Hypochlorous Acid net Weight 38 kg, high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed HDPE container (45/50 Kg 45 Kg container), chlorine concentration level 40-60% 65-70 % and delivered at STP, Complete all as specified and directed by Engineer-in-Charge. Make: Aditya birla or equivalent
Supply only bleaching powder suitable for water disinfection, Complete all as specified and directed by Engineer-in-Charge.
Dismantling Sewage submersible pumping set of cap 3 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including electric and piping connections complete, checking for satisfactory working, Complete all as specified and directed by Engineer-in-Charge. (Note : Cost of dismantling and refixing deemed to be included in quoted rate)
Dismantling Sewage submersible pumping set of cap 5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including electric and piping connections complete, checking for satisfactory working, Complete all as specified and directed by Engineer-in-Charge. (Note : Cost of dismantling and refixing deemed to be included in quoted rate)
Taking down air blower of Air blowers with working pressure 0.3 Kg/cm2 alongwith motor of capacity 5 HP with blower pipe of size 3", from the existing position after disconnecting all electrical connection and transportation to workshop for repair for un-serviceable parts complete and removing the defective parts, repair the air blower throughly including machine work and re-assembling the air blower and commssioning testing complete on full load, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for taking out & servicing of existing unserviceable Air Blower (of any Make) of capacity 5 HP pressure 0.3 Kg/cm2 with taking out of electric cable complete and reconnecting the electric and mechanical connection at existing location after carrying out following repairs, Complete all as specified and directed by Engineer-in-Charge. Note:- (i) Spare part required for replacement shall be measured and paid separetly under relevent items (ii) Replacement of Oil seal, locking arrangement of pully, gland packing with oil and greasing shall be deemed to be including in the quoted rate of this item.
Supply & fixing in replacement of "V" Belt (SPA 1250) unserviceable /worm-out 'V' belt of air blower etc, Complete all as specified and directed by Engineer-in-Charge. Makes:- Fenner/Dunlop/Nerlon/Super flix/Ecodrive.
Supply & Fixing in replacement of Gear oil 90 EP, Pressure Gear Oil etc., Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of air-filter for blower suitable size for existing air-filter etc, Complete all as specified and directed by Engineer-in-Charge.
Supply only Grease 30K, for using ensure protection of metal surfaces extending bearings, Hinges etc., Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for finding out defect of STPs panel and taking out burnt interconnection wiring including U/S and serviceable component for re-use including rewiring of panel using existing size of copper cable, ferrule, lugs, insulating materials, nut bolts washer of various sizes refixing serviceable items, Complete all as specified and directed by Engineer-in-Charge.
Comprehensive maintenance of RO Water Plant of capacity 2000 Ltr/Hr servicing complete: (a) Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (b) Major parts will be measured and paid separately Make of RO Plant : Ion Exchange
Supply & fixing in replacement of following spares for RO water Plant 2000 Ltr/Hr :-
20" Sediment filter
Anti scalent chemical
Membrane
Solenoid Valve
Sand filter media
Carbon media
Comprehensive maintenance of RO Water Plant of capacity 150 Ltr/Hr servicing complete: (a) Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (b) Major parts will be measured and paid separately Make of RO Plant : Ion Exchange
Supply & fixing in replacement of following spares for RO water Plant 150 Ltr/Hr :-
20" Sediment filter
Carbon block
Membrane
Anti scalent chemical
Solenoid Valve
Material and labour for maintenance of solar water heating system flat plate type including all water and electric connections of capacity 100 Ltrs per day and refixing the same in existing position after the following repairs and testing complete :- Location : Inaz Vig. (a) Replacement of the worn out/missing nuts bolts, washers, unions, sockets flanges and screw etc complete. (b) Descaling/desludging the hot water pipes and normal water by using appropriate chemicals/Anti corrosive/Anti scaling agent solution, cleaning and washing all copper tube & water circulated pipes of heat convetor sets throughly cleaning the complete solor pannel of making the tube scale free and reassemling the pannel. (c) Cleaning hot and cold water tanks, removing sludge and scale from the tank manually using suitable chemicals complete. (d) Repair of collector fins incl required welding works etc complete. (e) Testing on completion after Repair work and making the Solar Water Heater functional in each aspects. (Note : Cost of dismantling and refixing and minor repairs deemed to be included in quoted rate.
Supply & fixing in replacement of PVC Suction hose pipe at STP, working pressure 10 Kg/Sqcm of size 50/63 mm bore, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of PVC foot valve assembly complete of suitable size for pipe of size 50/63 mm bore, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Butterfly valves lever operated body grey cast iron of size 50mm bore, with all fittings confirming to IS specification, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of non return valves (NRV) body grey cast iron of size 50/63 mm bore, with all fittings confirming to IS specification, Complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of CPVC pipes of size 50mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, Complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of CPVC pipes of size 32mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, Complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of CPVC pipes of size 25mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Ball Valve of 50mm Dia Long Handle of size and connected at both ends for CPVC pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and including any addition / alteration any required for fixing and making good, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Ball Valve of 32mm Dia Long Handle of size and connected at both ends for CPVC pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and including any addition / alteration any required for fixing and making good, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Ball Valve of 25mm Dia Long Handle of size and connected at both ends for CPVC pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and including any addition / alteration any required for fixing and making good, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Flexible Flat of size 2.5 Sqmm 3 core, PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade including drawn through HDPE/PVC conduit of size 25 mm dia inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to light etc, Complete all as specified and directed by Engineer-in-Charge. Note: 1. Conduit, saddles & small excavation of cable in gardens deemed to be included in the quoted rate.
Supply & Fixing in replacement of Round strand Galvanized Iron Steel Wire Rope dia 8mm and connected clamp nut bolts fixed etc, Complete all as specified and directed by Engineer-in-Charge.
Spray Painting of Pump & Motor any type, any capacity upto 20 HP as per colour code (Shade) of MES specification after cleaning the dust particle of existing motor & Pump, Complete all as specified and directed by Engineer-in-Charge.
Servicing of DG set ('C' Check) of Cap 20KVA to 70 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following,Complete all as specified and directed by Engineer-in-Charge. (a) Lub oil filter. (b) Lubrication oil. Make of DG set: Ashok Leyland/ Greaves Cotton/ kirloskar Note: Defective parts if any other than listed at (a) to (b) above will be measured and paid separately
Supply only parts/ Items of DG set 50/62.5 KVA & Taking down old unservicable parts
Fuel Filter cum water seperator
Oil Filter
Air Filter Safety
Air Filter Primary
Fuel strainer
Engine Oil
Coolant
Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 20 KVA to 70 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint, Complete all as specified and directed by Engineer-in-Charge.
Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., Complete all as specified and directed by Engineer-in-Charge.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces inclduing painting, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors in exsisting conduit/ Provision of PVC cassing capping as per site requirment size conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed cassing capping, modular cover-plates and frame complete all as specified in IS: 732- 1989 and directed. NOTE: Circuit wire from DB to switch boards shall be included in quoted rate. Note (i) Exsisting Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of exsistng size is to be replace and rate are deemed to be inlcuded in quoted rate.(iii) PVC cassing capping measured and paid under relevent Item.
One light/ Bulb Holder /fan/exhaust point / bell point controlled by one, one way switch
One light point controlled by 2, Two way switch
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board..
Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size PVC medium grade surface/recessed cassing capping conforming to IS: 537 (Part 3)- 1983, colour-coded as specified in IS: 11353- 1985, and including modular cover plates, IS: 732- 1989, Complete all as specified and directed by Engineer-in-Charge. Note:- (i) Exsisting Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of exsistng size is to be replace and rate are deemed to be inlcuded in quoted rate.
One 16 Amp socket outlet, independent, with cables 2.5 mm² size
Supply & fixing in replacement of modular type 6 Amp one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of modular type 16 Amp one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of modular type 2/3 pin combined shuttered type 6 Amp socket conforming to IS: 1293- 2005, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of modular type 6 Amp bell-push conforming to IS: 8884- 1978 with finger proof terminal, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Bell multi music type 230 Volt, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of modular type 120 Watt step fan regulator of 2 module size, conforming to IS: 11037-1984, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of 6 Amp, 250 Volt high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Modular switch 2 way 6 Amp, 1 module, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of PVC Modular surface box of following size:-
1 or 2 Module of size 85mm x 85mm
3 Module of size 85mm x 115mm
4 Module of size 85mm x 145mm
6 Module of size 132mm x 135mm
Supply and fixing in replacment of Modular cover plate with frame of following size:-
1 or 2 Module of size 85mm x 85mm
3 Module of size 85mm x 115mm
4 Module of size 85mm x 145mm
6 Module of size 132mm x 135mm
Supply & fixing in replacement switch piano flush button, 240 volts, 6 Amps, single pole, one way (ISI marked), Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Socket outlet 2 in 1, 3 pin, 5 Amp flush type (ISI marked), Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of Socket outlet 3 pin, 16 Amp, flush type, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of switch piano flush button 230 V, 16 Amps, Single pole, one way ISI marked, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 Volt with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 Volt with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 Volt with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 4 way type, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for submain wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size in exsisting conduits / PVC Cassing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, Complete all as specified and directed by Engineer-in-Charge. NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Cassing capping shall be measured as one length.
2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire
2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
Supply & fixing in replacement of casing capping of 25 x 12 mm size, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of casing capping of 32 x 16 mm size, Complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, Complete all as specified and directed by Engineer-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling, Complete all as specified and directed by Engineer-in-Charge.
Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of wall mounted LED Tube light fitting 1 x 10 Watt LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of wall mounted LED Tube light fitting 1 x 20 Watt LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of LED Luminaires recessed mounted down lighter 18 Watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of 6 Watt LED spot light with multiple beam tilting angles, no UV radiation and dimmable ballast, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of square shape slim recessed mounted LED down light of capacity 36 Watt (2ft x 2ft) with die cast housing finished in white powder coating, Complete all as specified and directed by Engineer-in-Charge.
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ, Complete all as specified and directed by Engineer-in-Charge. Note- worn out parts shall be measured as separately.
Supply & Fixing in replacement of spare parts for Geyser
Heating element 1.5 KW with rubber gasket.
Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
Hot/Cold water connection pipe 450 mm length.
Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia
Indication lamp red and green suitable for geyser as required
Material & Labour for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush, refixing the front cover of indoor unit. Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressureized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of out door unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection, Complete all as specified and directed by Engineer-in-Charge. Note - Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule.
Material & Labour for detecting the cause of leakage in any type/capacity of 1.5/2 ton inverter / non inverter AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning, Complete all as specified and directed by Engineer-in-Charge. Notes :-(i) Dismantling of unserviceable compressor, cost of refrigarent gas and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates.
Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity, Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement over load protector suitable range and capacity
Supply & fixing in replacement Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply
Supply & fixing in replacement capacitor of 2.5 mfd suitable for blower fan motor of 1.5/2.0 ton AC
Supply & fixing in replacement thermostat switch of suitable for 1.5/2.0 ton AC
Supply & fixing in replacement Contactor relay of suitable for 1.5/2.0 ton AC
Supply & fixing in replacements Blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 20 Watt, 3 speed for indoor unit of split AC 1.5/2.0 TR of existing make complete
Supply & fixing in replacements condenser fan motor 1/8 to 1/12 HP, 900/1400 RPM, 60 Watt suitable for 1.5/2 TR split AC outdoor unit, single phase, of existing make complete. Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
Supply & fixing in replacements Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete
Supply & fixing in replacements PVC fan blower assembly for 1.5 /2TR split AC's any make
Supply & fixing in replacements Printed circuit board(PCB) with suitable for non inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection.
Supply & Fixing in replacement of defective cut open compressor/Uncut compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping and replacement of filter complete for split type AC's of the following capacity, Complete all as specified and directed by Engineer-in-Charge.
1.5 ton capacity
2.0 ton capacity
Supply & fixing in replacements Codenser Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacements Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacements Printed circuit board(PCB) with hand set of indoor, outdoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing with necessary electrical connection, Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of oudoor condencer unit of copper with 2 run of copper pipe of out door unit of split type AC 1.5/2.0 TR, Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of swing motor 230 Volt for 1.5/2.0 Ton indoor unit of split AC, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacements Blade set of fan motor of out door unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacements Blade set of fan motor of out door unit, made out of PVC Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacements copper tubing of size 3/8" suitable for split AC with nitrile self adheive foam wrapped with PVC insulation all around the pipe line, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacements copper tubing of size 5/8" suitable for split AC with nitrile self adheive foam wrapped with PVC insulation all around the pipe line, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement flexible PVC pipe for condense water outlet for Split AC as per existing, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for charging of refrigerant R-410/R-22/R-32 gas to air conditioner or as per existing /manufacturer instrcutions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for charging of refrigerant R-410/R-22/R-32 gas to air conditioner or as per existing /manufacturer instrcutions suitable for split air conditioner cap 2.0 ton after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of outdoor unit stand of metal including fixing accessories such as nut bolt washers and fastner for 1.5/2 Ton outdoor unit, Complete all as specified and directed by Engineer-in-Charge.
Material and labour for servicing/cleaning of water cooler of storage capacity/ nominal cooling capacity(Ltrs/hr) 80/40 & 120/60 litres with the use of antiscaling agent for internal steel water tank ,outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush, cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipments, cleaning of fins and tubes of condenser, repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap, Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repalcement hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler, Complete all as specified and directed by Engineer-in-Charge. Make : Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor and replacement with new electric motor, single phase 230 Volt of water cooler 40ltrs/hrs with condenser fan blade, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of following items of water cooler
Thermostat for water cooler capacity 40/80 ltr/hrs.
Push type Bib tap Cast copper alloy 15 mm Push type chromium plated.
PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15 mm dia GI Pipe.
Material and labour for carrying out repair /maintenance/ servicing of Refrigerator of any capacity by periodic cleaning of internal and external parts, cleaning of water collection area and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Refigerator in good working condition, Complete all as specified and directed by Engineer-in-Charge. Note: Defective spares required for replacement shall be measured and paid separately under respective items.
Material and labour for maintenance of Refrigerator any capacity with replacement of old/unsv spare parts as under including testing on load, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement condensor suitable for Refigerator of 195/ 250/ 300 ltr cap
Supply & fixing in replacement cooling effect tranmitting fan motor suitable for Refigerator of 195/ 250 / 300 ltr cap
Supply & fixing in replacement Compressor Relay suitable for Refigerator of 195/250 / 300 ltr cap or as per existing Make KCL/Rentrol/Indofos
Supply & fixing in replacement thermostat suitable for Refigerator of 195/250 / 300 ltr cap
Supply & fixing in replacement Compressor suitable for Refigerator of 250 / 300 ltr cap or as per existing
Material & Labour for charging of refrigerant R-134a gas to Refrigerator for the 230/250 Litre capacities as per existing /manufacturer instrcutions after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned, Complete all as specified and directed by Engineer-in-Charge.
Deployment of manpower, instrument, tools, and all connected accessories for testing of earth resistance of existing earthing at provided earth test point for each earth set by competent calibrated digital earth test meter electronic type along with accessories (earth rod set with Copper wire with clips) and recording the result dully signed with date by MES representative and contractor, Complete all as specified and directed by Engineer-in-Charge. NOTE:- (a) Testing of each earthing shall be carried out at the interval of 3 months and measurement shall be done each time separately and test result shall be maintained dully signed with date by MES representative and contractor. (b) Pouring of water in each earth pit is deemed to be included in the rate quoted. (c) Necessary arrangement to be made by the contractor for pouring the water in earth pits. Vehicle reqd for carrying/storage of water (upto to the site) with helper will be arranged by contractor and deemed to be included in the rate quoted. (d) Cost of Maintenance of carrying vehicle (if any) and cost of fuel reqd for veh is deemed to be included in the rate quoted.
Supply & fixing in replacement Test point terminal block made of gun metal or phosphorus bronze size of 75mm x 75mm x 25 mm drilled and screwed with 3 Nos 8mm dia, 25mm long screw, fixed in and including SMC junction box of size 170 x 170 x105mm hinged door fixed on wall, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for PCC earthing pit in PCC 1:2:4 type B-1 of internal size 300mm x 300mm x 300mm with 120mm thick wall and 700mm x 700mm x 150mm thick bed concrete and 50mm thick precast chamber cover of RCC 1:2:4, type B1 for, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), complete all as shown in the electrical plate No 3 of SSR part –I including demolition of old pit, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement mild steel galvanised earth strip of size 25 x 4 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for marking of earthing pit (GI earth / Copper earth / Chemical earth) with two or more coat synthetic enamel paint, colour & pattern as approved by the Engr-in-Charge, Letter size shall not be less than 50 mm, Complete all as specified and directed by Engineer-in-Charge.
Material & Labour for bore Earthing 150mm bore for earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length, top edge of GI pipe not less than 1.25 metres below ground level, connected with earthing lead of 25 x 4 mm GI strip to the earthing test point and filling of charcol dust, salt etc and testing on completion, Complete all as specified and directed by Engineer-in-Charge. Note: IR Value should be less than 5 Ohms. Note: GI earth stip of size 25 x 4 including installation 7.5 Mtr is deemed to be included in the unit rate.
fakhrie apostrical (BID ID -3133331)
ALBA AC AND REF SERVICES (BID ID -3145792)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .