Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹36.5 L+₹1.2 L (3.42%)Rejected-Finance 2 B KRISHNA NAGAR AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹41.7 L+₹6.4 L (18.1%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹44.9 L+₹9.5 L (27.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
15 May 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
CLEANING MAINT OF CENTRAL SEWAGE SYSTEM IN SECTOR C UNDER GE UTILITY AMBALA CANTT
2023_MES_589322_1
CA NO GE U AMB T 13 OF 2023-24
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹92,000
22 May 2023
13 Apr 2023
18 May 2023
13 Apr 2023
15 May 2023
1 May 2023
13 Apr 2023 - 20 Apr 2023
Amount
Cleaning of under ground EXISTING SEWAGE DEEP TRUNK LINE SGSW/RCC/HDPE pipe line of any dia of pipes line and depth exc 2.5 mtr and above including manholes of any size working/running conditions involving removal of blockages of any kind of sewage lines and manholes by means of Heavy truck mounted High pressure Suction Cum Jetting Machine including desludging, descaling and dechoking of lines whereever required, flushing the entire stretch with water making the stretch clean and funtional. Removal & depositing any type of sludge/debries to excavated area, spreading necessary Insecticides where sludge is deposited all as specified and directed by Engr in-charge. (Note :- All sludge/debried should be deposited in nearest pit & cover with sand & necessary disinfection be carried out OR Removing/depositing of sludge/debries not exc 500mtr beyond the periphery of defence land & covering the entire sludge & solids with local earth.Sewage Lines in area for cleaning of depth Max 10 mtr.)
Notes for Ser item Nos 1 :-The quoted rate of contractor shall comprise the following :- (i) Contractor shall provide Heavy truck mounted suction cum jetting machine on each day from 9 A.M to 5 P.M of minimum following specification for cleaning Sewage Deep Lines:- (a) Minimum Tank capacity of machine - 8000 ltr (b) Minimum Working pressure range of jetting pump - 155 bar (c) Minimum water flow for pump of jetting machine - 269 LPM (d) Minimum Suction hose length - 30 mtr (e) Minimum Jetting Hose length - 120Mtr (f) Minimum Vacuum Pump Power - 4.4 Hp@RPM (g) Minimum Vacuum Suction depth - 8 mtr
(ii) Contractor shall provide minimum 3 Nos skilled/unskilled menpower , High Qualified driver with Heavy duty Motor Vehicle License on each day for attending and completing the complaints as per the users satisfaction. However, the numbers of skilled and unskilled menpower shall be increased as directed by Enginner-in-Charge depending upon the requirements/ number of complaints registered at the complaint center all as directed by the Engr-in-charge
(iii) If Contactor does not provide Heavy truck mounted Suction jetting machine of above mentioned specifiacation with minimum number of staff as mentioned then a penalty at the rate RS 20000/- per day shall be levied on the contractor and recovery for the same shall be affected from contractor's til that day when Contractor provides above all mentioned for cleaning of Sewage Lines.
(iv) Complaints cell for receiving complaints from JE or as directed by Engr-In-Charge shall be opened by the contractor from 09.00 am to 0 5.00 pm at MES service centre of AGE E/M-I under GE (U) Ambala Cantt. The complaints pertaining to sewage cleaning and opening of blockage etc. against serial item No 1shall be attended and completed within 24 hours after lodging/ receipt of complaints. Minimum Avg Cleaning of Sewage line cleaning appx 100-150 mtr . Contractor shall ensure that all the complaints shall be attended and completed within above prescribed schedule/ time period, failing which, a penalty at the rate of double the quoted rate for that particular trade work/cmplaint per day till the satisfactorily completion of complaint shall be levied on the contractor and recovery for the same shall be affected from contractor's dues. A separate register shall be maintained for recording the same and shall be signed by both the contractor or his authorised rep and Engr-in-charge.
(v) For each complaint in location, a docket slip shall be prepared by the contractor/ his representative and handed over to related tradesman, etc. for attending the complaint and after satisfactorily completion of complaint, docket slip shall be submitted to concerned executive on day of register of complaint, which shall be got signed from the occupant and shall be produced at the time of payment to be made to the contractor.
(vi) Format of docket slip and complaint register which shall be kept in complaint cell (complaint slip shall be as per sample kept in AGE office) are attached as per Appendix 'E' and Appendix 'F' of tender documents. Stationery i.e. log sheets, docket slips, job cards, complaint registers, handing taking registers, etc. shall be provided by the contractor without any extra cost to the department and cost thereof shall deemed to be included in quoted rates by the contractor against respective item of schedule 'A'. The complaint slip shall be prepared by the contractor or his authorised rep and handed over to the tradesmen and necessary entry shall be made in the complaint register and will be handed over to to concerned JE / the Engr-in-Charge next day. Contractor shall maint seprate register for lodging the complaints and the same shall be produced to concerned JE / Engr-in-Charge on next day.Length of cleaning of sewage line will be mentioned by contractor per day and will be certified by Engr-in-Charge .
(vii) : Necessary transportations, diesel , tools, plants, ladders, cleaning rods/Bamboos, all medical safety equpiments etc. including to complete the jobs/complaints shall be provided by the contractor without any extra cost to the department and cost thereof shall deemed to be included in quoted rates by the contractor .
Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins,arches, pillars, etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches, not exc 1.5 mtr wide and n.exc 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and n.exc 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
All as per item No 4 above but exc 1.5m deep & not exc 3.00m deep .
All as per item No 4 above but exc 3.0m deep
Excavating over areas by meachanical means (hydraulic Excavator), n exc 1.5 m deep and getting out in soft/loose soil all as specified and directed.
All as per item No 7 above but exc. 1.5 mtr and not exc.3.00 mtr deep.
All as per item No 7 above but exc. 3 mtr
Use and waste of timbering as planking and strutting for excavations in trenches in soil, including wales, struts, open poling boards, etc. as may be necessary and fixing and removal n exc 1.5 m deep
All as per item No 10 above but exc. 1.5 mtr and not exc.3.00 mtr deep.
All as per item No 10 above but exc. 3.00 mtr
Important Notes for Srl Item No. 4 to 12 : (i) Bailing and Pumping out of water where required shall be carried out as per clause 3.17 & 3.18 of SSR (Part-II) of 2009. (ii) Timbering, planking and strutting if required shall be carried out as per clause 3.24, 3.24.1 & 3.24.6 of SSr (Part-I) of 2009 and paid separetely in item No 10 to 12 as above. (iii) The earth work shall be as per authorised width as per clause 3.2.3 of SSR part-II.There will be no extra payment for Earth work to Contractor .Contractor must quote the earth rates accordingly. (iv) Sand cushioning/lean conrete will be provided for stablizing of mud strata if required (v) The rates quoted by contractor for Srl Item No. 4 to 8 shall deemed to be included for provisions described in note (i),( ii), (iii),(iv) here-in-before. Nothing extra shall be paid on this account. (vi) Contractor shall take level wher depth of excavation more than 1.5 m. Complete record of level book shall be produced at the time of payment.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 300 mm
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 250 mm
M&L Concrete bed to 300mm internal dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; in PCC (1:3:6)
M&L Concrete bed to 250mm internal dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; in PCC (1:3:6)
M&L for DWC(Double wall corrugated) HDPE pipes of size 300mm internal dia ) confiRMing to IS -16098 Part-II of strength/stiffness class SN 8 laid in trenches on conrete bed to level/gradient , jointing as per manufacturers instructions including jointing accessories as required complete all as specified as directed by Engr-In-Charge.
M&L for DWC(Double wall corrugated) HDPE pipes of size 250mm (internal dia ) confiRMing to IS -16098 Part-II of strength/stiffness class SN 8 laid in trenches on conrete bed to level/gradient , jointing as per manufacturers instructions including jointing accessories as required complete all as specified as directed by Engr-In-Charge.
Returning, filling in foundation/trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil/materials to a distance not exceeding 100 Mtr and depositing where directed at a level not exceeding 1.5 Mtr from the starting point, complete all as specified and as directed by Engineer-in-Charge.
M&L for plain cement concrete M-10, as in foundations, and mass concrete over rammed earth .
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter ( Flat rough finished).
Use and waste of form work to faces of walls, retaining walls, RCC circular manholes, parapets and stair cases rough finished curved surfaces of manholes etc all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat
Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs n exc 20 cm wide & sides of RCC/PCC bands in walls, horizintal or sloping & similar work exc 10cm but n exc 20cm wide Roughed finished surface of concrete
S&F mild steel TMT CRS bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified.
All as per srl item No 26 here-in before but 6 mm to 8 mm dia.
M&L RCC M-25 design mix using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete inculding demolition of old RCC complete all as specified and directed.
M&L for reinforced cement concrete M-25, 20 mm graded aggregates (design mix) in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses including demolition of old RCC complete all as specified.
M&L RCC M-25 design mix using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like inculding demolition of old RCC complete all as specified and directed.
Cutting into existing manholes for connecting new drains 300/250mm dia, making good to pipe & rendering, cutting out existing benching for & foRMing branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, & refoRMing benching as required
Cutting existing road incl repairing after laying of pipe line with premix carpet, WBM and hardcore complete as per existing specifications complete all as specified and directed by Engr - in - Charge.
M&L PCC in surface channels,benching in sewers,drains etc type B1 (1:2:4) using 20 mm graded stone aggregate
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stopped ends etc complete all specified and directed.
S&F manhole cover SFRC factory made of size 560 mm dia with steel frame heavy duty all as specified
S&F Rolled mild steel Stairs (framed) including stringers, treades, landing, balusters, hand rails etc, including cleats,brackets, etc. complete (GDE Fe 410-W or Grade E-250).
M&L PCC in sub base, foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate
M&L Machine pressed precast concrete interlocking paver block (50% grey and 50% coloured) any shape and size confiRMing to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment over and including 50 mm sand cushion all as directed.
Lavour only for brick work with sub class ’B’ brick (For raising man holes)straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1 :4 complete all as specified and directed by Engr-in Charge.( Bricks shall be used obtained from ser Item No 2 here in before
M&L 15 mm thick rendering in cement mortor 1:4 with water proofing compound (2% by weight of cement)finished even and smooth without using extra cement on fair faces of brick work or concrete surfaces. (Note- WPC shall be measured and paid separetely)
Supply only water proofing compound.
M & L providing cement concrete (1:2:4) type B1 (20 mm graded aggregate ) in lintels upto 1.5 m clear span , cills, steps; seimic and other similar bands , plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates,water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed.
M&L for pre-cast cement concrete 1:2:4 type B1 (using 20mm graded aggregate) as in man hole cover, with plain fair faces including chamfers, weathering throttling etc and set in cement mortor (1:4) complete with joint to match in cl necessary form work complete all as specified and as directed by Engr-in-Charge
Note:- Amount of credit of Rs. 52250.00 for retrieved materials is mentioned in Schedule of Credit mentioned in tender documents in pdf form which will be deducted offline while acceptance of tender.
Puneet Sharma
KULWANT SINGH
M/s Kang Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .