Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC HYDERABAD TELANGANA 500076 INDIA UDYAM TS 02 0009467 | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹19.1 L+₹2.5 L (15.1%)Rejected-AOC | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹20.2 L+₹3.7 L (22.3%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-AOC Quoted L3 | |
| 4 | L4₹24.0 L+₹7.4 L (44.9%)Rejected-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L4 | Rejected-AOC Quoted L4 |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
1 Nov 2021, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
REPAIR TO STREET LIGHT DG SETS AND CONNECTED WORKS, REPAIR TO HT VCB, GOD, LT PANEL AND ELECTRIC CABLE AT AF STN HIGHGROUND UNDER GE (AF) CHANDIGARH
2021_MES_473395_2
GE(AF)/CHD/T-27/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HighGround
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹39,000
27 Apr 2022
12 Oct 2021
3 Nov 2021
12 Oct 2021
1 Nov 2021
18 Oct 2021
12 Oct 2021 - 15 Oct 2021
Amount
Maintenance of DG set of any make, type, model as per set norms of the original manufacturer set and by the authorised rep of the company after unscrewing nut, bolts, screws etc. for servicing, maintenance, tigthtening, adjustment & cleaning of all moving and stationary parts of DG set, complete and segregating the parts for repair/ refixing/ replacing of capacity 10KVA installed at IMMOLS , complete all as specified and directed. Make of DG sets :- kirloskar/Crompton Greaves/Ruston/Ashok Leyland Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective parts/ engine oil to be replaced will be measured & paid separately under supply only item as apended below.
All as per Serial Item No. 1 here-in-before but capacity 30 KVA
All as per Serial Item No. 1 here-in-before but capacity 35 KVA
All as per Serial Item No.1 here-in-before but capacity 40 KVA
All as per Serial Item No. 1 here-in-before but capacity 63 KVA
All as per Serial Item No. 1 here-in-before but capacity 75KVA
All as per Serial Item No. 1 here-in-before but capacity 82.5KVA
All as per Serial Item No. 1 here-in-before but capacity 400KVA
Supply only under mentioned spare/parts suitable for the DG set complete all as specified and directed:-
Primary fuel filter element for DG set capacity 10KVA
Primary fuel filter element for DG set capacity 30KVA
Primary fuel filter element for DG set capacity 35KVA
Primary fuel filter element for DG set capacity 40KVA
Primary fuel filter element for DG set capacity 63KVA
Primary fuel filter element for DG set capacity 75KVA
Primary fuel filter element for DG set capacity 82.5KVA
Primary fuel filter element for DG set capacity 400KVA
Secondry fuel filter element for DG set capacity 10KVA
Secondry fuel filter element for DG set capacity 30KVA
Secondry fuel filter element for DG set capacity 35KVA
Secondry fuel filter element for DG set capacity 40KVA
Secondry fuel filter element for DG set capacity 63KVA
Secondry fuel filter element for DG set capacity 75KVA
Secondry fuel filter element for DG set capacity 82.5KVA
Secondry fuel filter element for DG set capacity 400KVA
Air filter element for DG set capacity 10KVA
Air filter element for DG set capacity 30KVA
Air filter element for DG set capacity 35KVA
Air filter element for DG set capacity 40KVA
Air filter element for DG set capacity 63KVA
Air filter element for DG set capacity 75KVA
Air filter element for DG set capacity 82.5KVA
Air filter element for DG set capacity 400KVA
Oil filter element for DG set capacity 10KVA
Oil filter element for DG set capacity 30KVA
Oil filter element for DG set capacity 35KVA
Oil filter element for DG set capacity 40KVA
Oil filter element for DG set capacity 63KVA
Oil filter element for DG set capacity 75KVA
Oil filter element for DG set capacity 82.5KVA
Oil filter element for DG set capacity 400KVA
Fuel line complete for DG set capacity 10KVA
Fuel line complete for DG set capacity 30KVA
Fuel line complete for DG set capacity 35KVA
Fuel line complete for DG set capacity 40KVA
Fuel line complete for DG set capacity 63KVA
Fuel line complete for DG set capacity 75KVA
Fuel line complete for DG set capacity 82.5KVA
Fuel line complete for DG set capacity 400KVA
Material and labour for taking out radiator and repairing/brazing to make it leakage free, cleaning and re-fixing the radiator including testing for DG set capacity 10KVA to 40KVA, complete all as specified and directed.
All as per item No. 50 here-in-before but DG set capacity 63KVA to 82.5KVA complete all as specified and directed.
All as per item No. 50 here-in-before but DG set capacity 400KVA complete all as specified and directed.
Supply only lubricant oil (Engine oil) SAE30 (Make as recommended by the manufacturer of DG set and as approved)
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 180AH, complete all as specified and directed.
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 92AH, complete all as specified and directed.
Supply and fix, battery lead not less than 1.5mtr long, made out of 50Sqmm copper cable with terminal of brass with marking (+)/(-) and fixing in position and testing, including taking down and removal, complete all as specified and directed.
Supply and filling, engine coolant in radiators of DG sets as per DG set manufacturer's recommendations at different locations, brought at site in sealed packets, complete all as specified and directed.
Maintenance, repair, servicing and calibration of automatic mains failure panel, DC & 415/440 volt AC supply operated system by locating faults and replacement of unserviceable parts and components for DG set 10KVA to 400KVA and testing on completion , complete all as specified and directed. Make of DG sets:- Kirloskar/Crompton Greaves/Ruston/Ashok Leyland Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective parts/ engine oil to be replaced will be measured & paid separately under supply only
Repair of faulty worn out control wiring DC/AC for engine starting and off, with adequate and suitable size copper conductor wire, connected with proper copper lugs & terminals through protection pipe/casing, complete all as specified and directed.
Repair of worn out/faulty internal wiring of controls and timers, indicating/measuring instruments through various control fuses and relays with suitable and adequate size of copper conductor wire, connected with suitable copper lugs and terminals, complete all as specified and directed.
Replacement of worn out small control fuses, indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order , complete all as specified and directed.
M & L for repairing battery charging dynoma including replacing worn out/unserviciable spares up to the capacity of 82.5 KVA all as specified and directed by Engineer in charge
M & L for repairing battery charging dynoma including replacing worn out/unserviciable spares of the capacity of 400 KVA all as specified and directed by Engineer in charge
M & L for repairing self starfer including replacing worn out/unserviciable spares up to the capacity of 82.5 KVA all as specified and directed by Engineer in charge
M & L for repairing self starfer including replacing worn out/unserviciable spares up to the capacity of 400 KVA all as specified and directed by Engineer in charge
M & L for replacing the unserviciable AVR of DG sets up to the capacity of 82.5 KVA and testing complete all as specified and directed by Engineer in charge
M & L for replacing the unserviciable AVR of DG set of capacity of 400 KVA and testing complete all as specified and directed by Engineer in charge
S & F Power contractor 3 pole 200 Amps 415 volts operating coil , complete all as specified and directed. Make - Havells/L & T/ABB
S & F Power contractor 3 pole 315 Amps 415 volts operating coil , complete all as specified and directed. Make - Havells/L&T/ABB
S & F Power contractor 3 pole 400 Amps 415 volts operating , complete all as specified and directed. Make - Havells/L&T/ABB
M & L repairs to unserviceable street/security lights fittings of LED, of any wattage and size by taking down from poles/buildings after disconnecting the electric connection, replace the unserviceable drive ,PVC connector etc, cleaninng, refixing the light fittings at its original position after rectifying the defects and connecting to street light feeder including testing complete all as specified and directed. Note :- (i) Replacement of parts like drive , will be measured and paid seperatily as supply only (ii) The cost of labour ,tools and minor spares required for replacement of parts shall deem to include in the unit rate quoted by the contractor.
Taking down the existing light fittings multi mounting brackets from High Mast Pole/Structure (12 mtrs High) for repairs/replacing the defective parts and refixing the same in original position after carrying out necessary repair/replacement of parts i.e. unserviciable ignitor, ballast, capacitor from control gear box , complete all as specified and directed.
M & L for PVC insulated stranded aluminium conductor, 1100 volts grade heavy duty cable of size 2.5Sqmm 2 core (from junction box to street light fitting mounted on steel tubular/PCC pole) including taking down existing unserviceable cable, complete all as specified and directed.
Supply only Open construction ballast copper wounded for 400 watts HPSV/MH lamps,complete all as specified and directed.
Supply only Metal halide lamp 400 watts, 230 volts, single/double ended tubular/ballon type,complete all as specified and directed.
Supply only electronic drive suitable for LED street light /Flood light of capcity up to 90W all as specified and and directed by Engineer in charge
Supply and fix in replacement of LED street light fitting 60W AC 230V 50 Hz powder coated pressure die cast alluminum housing power LED with heat resistant toughned glass IP 66 complete all as specified and diredted by Engineer in charge Make - Havells Cat No ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent in Appx 'A'.
Supply and fix in replacement of LED street light fitting 35W AC 230V 50 Hz powder coated pressure die cast alluminum housing power LED with heat resistant toughned glass IP 66 complete all as specified and diredted by Engineer in charge Make - Havells Cat No ENDURACITYLITEPLATPLUSSL35WLED757SASBOPC or equivalent in Appx 'A'.
Supply and fixing in replacement LED flood light luminare 150Watts comprising of single piece pressure die cast aluminium alloy housing powder coated with clear acrylic bowl, complete prewired fixed to pole/wall bracket and connected with flexible copper conductor cable. Make - Havells Cat No JETAIRISFLS150WLED757PSYMLTG or equivalent in Appx 'A'.
Supply and fixing LED post to latern 25Watts comprising of single piece pressure die cast aluminium alloy housing powder coated cone round milkey post top ,complete prewired fixed to pole/wall bracket and connected with flexible copper conductor cable of size 1Sqmm three core suitable length, including taking down old fitting, complete all as specified and directed. Make- Havells Cat No CORALPT25WLED757PSYMTOPC or equivalent in Appx 'A'.
S & F in replacement of 200x160x98mm PVC junction box having IP 65 protection with metric knockouts for 16/25 sqmm cable entry with terminalals /bus bar 4 pole including provn of one MCB 6 Amps complete all as specified Make Sintex/Hensel
S & F in replacement LED 10 watts round type bollard garden light fittings diffuser at the upper portion act as a beacon of path guidance all as specified and directed by Engineer in charge Make- Havells Cat No MINIMOUNTBL10WLED830PSYMTOPMMAS(0.3M) or equivalent in Appx 'A.'
Supply and fixing Water pump for DG sets suitable upto to the capacity of 82.5 KVA including diamantling and reifxig the accessories of prime mover all as specified and directed by Engineer in Charge
Supply and fixing in replacemnt of automatic battery charger suitable for battery capacity up to 2x12 V 180 AH having Ammeter and charge cut option complete all as specified and directed
Supply, Install test and commissioning in replacement with new indoor type AMF panel board suitable for control of 2 nos DG Sets 75 KVA and commercial supply made out of CRCA sheet of 2mm thickness totally enclosed, weather dust and vermin proof with front and rear opening gates voltage 440 volts 3 phase 4 wire 50 cycles having aluminium bus bar of suitable capacity for phase 4 wires 50 cycles having aluminium bus bar of duly colour coated with coloured heat shrinkable PVC sheelves including two coats of finishing Siemens gray paint over one coat of primer red oxide with including necessory mounting on floors for and comprising the following accessories
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Material and labour, locally available, sub class `B’ bricks (old size), laid flat and dry perpendicular to the direction of cable adjacent to each other, in trenches over the cable for protection, complete all as specified and directed.
Relaying only well burnt brick sub class 'B' old size brick laid dry in trenches with width equal to the length of the brick , complete all as specified and directed. Note:- Bricks are to be reused retrived during the cable taking out
Taking out / down old existing LT 1100volt grade cables, size 2x10Sqmm, aluminium conductor 2core, XLPE/ PLCA/ PVC, armoured, laid in trenches, including bricks for protection, sand cushioning and stacking, removal to store for re-use or for credit, complete all as specified and directed Note : Excavation shall be measured and paid for separately
All as per Serial Item No.93 here-in-before but 16Sqmm 2Core size
All as per Serial Item No. 93 here-in-before but 16Sqmm 4Core size
All as per Serial Item No. 93 here-in-before but 35Sqmm 3.5Core size
All as per Serial Item No. 93 here-in-before but 50Sqmm 3.5Core size
All as per Serial Item No. 93 here-in-before but 95Sqmm 3.5Core size
All as per Serial Item No. 93 here-in-before but 150Sqmm 3.5Core size
All as per Serial Item No . 93 here-in-before but HT cable 95Sqmm 3Core size
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 10Sqmm 2 core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Returning filling & removal of earth, sand cushioning and bricks for protection of cable shall be measured and paid separately.
All as per Serial Item No. 101 here-in-before but 16Sqmm 2Core size
All as per Serial Item No. 101 here-in-before but 16Sqmm 4Core size
All as per Serial Item No. 101 here-in-before but 35Sqmm 3.5Core size
All as per Serial Item No. 101 here-in-before but 50Sqmm 3.5Core size
All as per Serial Item No. 101 here-in-before but 95Sqmm 3.5Core size
All as per Serial Item No. 101 here-in-before but 150Sqmm 3.5Core size
Supply, laying, jointing, testing and commissioning of High Tension (HT) XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armoured, armoured, heavy duty, electric power cable, cross sectional area 95Sqmm 3core aluminum conductor 11000volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Returning filling earth work, sand cushioning and bricks for protection of cable shall be measured and paid separately.
Supply, jointing & testing, indoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor cable, 3core, 95Sqmm size cable, complete including taking dwon old jointing kit all as specified and directed
Supply, jointing & testing, outdoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armored aluminium conductor cable, 3core, 95Sqmm size cable, complete including taking dwon old jointing kit all as specified and directed
Supply, jointing & testing, straight through joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor, 3core, 95Sqmm size cable,including taking dwon old jointing kit complete all as specified and directed
Supply and laying / fixing , GI pipe light grade 100mm dia bore for cable protection fixed to pole/wall or laid under floor/roadv /pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and directed. Note: Boring of holes under road etc. shall be measured and paid separately.
All as per item No 112 here - in before but GI pipe 80mm complete all as specified and directed.
All as per item No112 here - in before but GI pipe 50mm complete all as specified and directed.
Material and labour for switch air break, gang operated triple pole ,mechanically operated, mounted on 12 insulators including drop out insulators including 3 nos barrel type drop out fuses and steel frame with operating mechanism worked from ground level with 25mm light grade GI tubing for current rating upto 400 amps,11000 volt including taking down old and removal complete all as specified and directed.
Material and labour for lightening arrestor high tension ,expulsion type complete with all fittings, transmission class ,discharge capacity 65 kilo amp ,suitable for 11000 volt grade system fixed in position including disconnecting and taking down old and removal complete all as specified and direced
Supply and filling of transformer oil of superior quality having di-electric strength not less than 40 KV at 4.0mm gap, ISI marked and filling into transformers and other equipments installed at various locations, after taking out old unserviceable oil, complete all as specified and directed. Note:- (i) Transformer oil will be supplied in duly filled in sealed drums. (ii) Necessary test certificate provided from authorised lab or state electricity board test lab.
Supply and fixing in replacement the under mentioned spare/parts of transformer capacity from 50 KVA to 400KVA, complete all as specified and directed.
Air breather assembly with silica gel
HT side procelain bush 11KV (Set of 03) with brass studs, nuts & washers, rubber gasket etc
LT side procelain bush 415V upto 100KVA transformer (Set of 04) with brass studs, nuts & washers, rubber gasket etc
LT side procelain bush 415V upto 200KVA - 250KVA transformer (Set of 04) with brass studs, nuts & washers, rubber gasket etc
LT side procelain bush 415V upto 300KVA - 400KVA transformer (Set of 04) with brass studs, nuts & washers, rubber gasket etc
Dismantling/Strip opening of the HT VCB 11KV 400 Amps for calibration, repairing, preventative maintenance, servicing including replacement of worn out parts to make it fully functional, reassembling the same after repair, installation to its original position, connection input/output supply, testing to its full load capacity and all other relevant tests as per IE/IS rules, complete all as specified and directed. Note: Spare parts required for repair/replacement shall be maeasured and paid separately.
Supply and fixing in replacement under mentioned spare/parts 11KV, 400 Amps HT VCB, any model/type of make :- Kirloskar/Crompton complete all as specified and directed.
Supply only, Potenional Transformer (PT) of 11KV/110V , totally enclosed, sealed and stamped, epxoy filled, heavy duty, suitable for 11 KV 400 Amps HT VCB, complete including taking dwon old PT all as specified and directed.
Supply only, Micro process based relay heavy duty, suitable for 11 KV 400 Amps HT VCB, complete inlcuding taking down old relay all as specified and directed.
Supply only, vaccum interruptor for VCB, complete all as specified and directed.including taking down old interruptor
Supply only, trolly insulator for mounting vaccum interruptor for VCB, complete all as specified and directed.
Supply only, epoxy fibre base plate for interruptor, complete all as specified and directed.
Supply only, epoxy insulator for bus bar supports, complete all as specified and directed.
Supply only, finger moving contact (Made up of six, each male and female, fingers), spring loaded, heavy duty, suitable for 11KV, 400Amp, HT VCB, complete all as specified and directed.
Supply only, Current Transformer (CTs) of CTR 50-25 / 5Amps, totally enclosed, sealed and stamped, epxoy filled, heavy duty, suitable for 11 KV 400 Amps HT VCB, complete all as specified and directed.
Supply and fix in replacement of spout type insulator suintable for HT VCB including cleaning the bus bar all as specified and directed by Engineer in Charge
Servicing of Battary Bank, and checking calibration and time gap, adjustment of earth fault relay,replacement of battery of existing capacity, over current relay and reconnecting all the relays to their respective circuits and locations, of HT VCB 11 KV 400 Amps, and testing on completion to the entire satisfaction of Engr-In-Charge, complete all as specified and directed.
Supply and fix, in replacement MCCB, four pole, 400Amps, 415 volts, 50 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, four pole, 250Amps, 415 volts, 35 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, four pole, 200Amps, 415 volts, 35 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, four pole, 160Amps, 415 volts, 25 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, three pole, 250Amps, 415 volts, 35 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, three pole, 200Amps, 415 volts, 25 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, three pole, 160Amps, 415 volts, 25 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, three pole, 125Amps, 415 volts, 25 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Supply and fix, in replacement MCCB, three pole, 63Amps, 415 volts, 16 KA, 50Hz , with adjustable thermal and magnetic release, complete with extension links and making connection in panel board, complete all as specified and directed.
Material and labour, Cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section Fe-290 grade E-165 quality including nuts, bolts, washers, and welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminium paint over a coat of red oxide primer, complete all as specified and directed.
Material and labour, painting two coats of aluminium paint to steel tubular poles of any description (external surface only) including MS cross arms etc making of 5 strips of width 300mm each (03 Nos Sky blue and 2 No. white) writing pole No. with black paint with letters/figures in girth 3 inch, including preparation of old painted surface, complete all as specified and directed.
Material and labour, painting two coats of aluminium paint to MS cross arms only fitted with PCC poles of any description and making of 5 strips of width 300mm each (03 Nos Sky blue and 2 No. white) writing pole No. with black paint with letters/figures in girth 3 inch, including preparation of old painted surface, complete all as specified and directed.
M & L preparation of old steel suface over 10cm width or grith not otherwise described and applying a coat of synthetic enamal paint to LT feeder pillar box all as specified and directed by Engineer in charge
M & L for chequered plate as in duct cover complete all as specified and directed by Engineer in Charge
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm complete all as specified.
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm complete all as specified.
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 150 Sqmm complete all as specified.
M & L cable jointing kit for 1100 Volts (Earthed) grade cable for straight through joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 Sqmm to 300 Sqmm complete all as specified.
Supply and fix in replacement of factory made indoor type bus bar chamber box wall mounted type made out of 2 mm thick CRCA sheet powder coated single door of size 60cmx60cm x30 cm having insulated copper bus of capacity 200 Amps three phase installed on porcelin insulator , all as specified and directed by Engineer in Charge
S & F in repair on-load change over switch four pole, 200A, in sheet steel enclousure complete all as specified.
S & F in repair on-load change over switch four pole, 400A, in sheet steel enclousure complete all as specified.
Supply, installation, testing and commissioning in replacement of LT feeder pillar box 3 Phase 4 wire, 415 volts outdoor type made out of 3mm thick MS sheet duly powder coated, weather proof, finished internally/externally with sufficient working space, mounted on angle iron frame 40mmx40mmx6mm, fixed in PCC 1:2:4 not less than 500mm above the ground level, connecting with all incoming/outgoing cable with the thimbles/lugs/cable glands, bus bar, opening at both side i.e. front/back with locking arrangements, all the accessories pre connected with alluminum bus bar RYB 200Amp and complete with following:- (a) MCCB 4 pole, 160Amp, 415 Volts, 25KA, 50Hz complete with extension links and making connection with panel - 01 No. (b) MCCB 40A 4pole, 415Volts 50Hz complete with extension links and making connection with panel - 05 Nos.
Note:- Amount of credit of Rs. 62813.00 for retrieved materials is mentioned in Schedule of Credit Page No 110 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Sabhyata Electrical and Mechanicals
R D Bansal
HARISH SALES CORPORATION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .