Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 CrAdmitted-Finance | ₹26.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹27.0 CrAdmitted-Finance | ₹27.0 Cr | L2 | Admitted-Finance |
| 3 | L3₹27.9 CrAdmitted-Finance | ₹27.9 Cr | L3 | Admitted-Finance |
| 4 | L4₹29.4 CrAdmitted-Finance | ₹29.4 Cr | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Ess Ess Enterprises & Electronics L1 | MS Anil Kumar Kapahi Contractor L2 | S K Integrated Consultants L3 | MS ABRAQ INFRASTRUCTURES LLP L4 |
|---|---|---|---|---|---|---|---|
| 1.00EARTH WORK | |||||||
| 2.00 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50m and lift upto 1.5m in : All kinds of Soil: | 2,453.53 | Sqm | - | - | - | - |
| 3.00 | Earth work in excavation by manual means over areas (Exceeding 30 cm and upto 1.5 mtr in depth, 1.5 mtr in width as well as 10 sqm. on plan) including disposal of excavated earth upto 1 mtr from cutting edge, disposed earth to be levelled and neatly dressed in : All kinds of Soil | 67.95 | Cum | - | - | - | - |
| 4.00 | Earth work in excavation in bulk by mechanical means (Hydraulic excavator) including disposal of excavated earth within complex or as directed by the Engineer-in-charge and disposed earth to be levelled and neatly dressed and consolidation with power road roller: All kinds of soil | 2,719.67 | Cum | - | - | - | - |
| 5.00 | Filling available excavated earth in trenches, plinth, sides of foundation incl ramming and watering | 754.25 | cum. | - | - | - | - |
| 6.00 | Supplying chemical emulsion in sealed containers i/c delivery as specified.: Chlorpyriphous / Lindane emulsifiable concentrate of 20% | 435.25 | Litre | - | - | - | - |
| 7.00Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : | |||||||
| 7.01 | Along external walls where the apron is not provided using chemical emulsion @ 7.5 Ltr/sqm of the vertical surface of the substructure to a depth of 300 mm including excavation of channel along the wail & redding etc. with chlorophyilpros/ Lindane E. C 20% with 1% concentration | 560 | RM | - | - | - | - |
| 7.02 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 ltr/ linear mtr. including drilling and plugging holes etc.: with chlorophyriphos/ Lindane E.C. 20% with 1% concentration | 850 | RM | - | - | - | - |
| 8.00 | Disposal of surplus excavated earth by mechanical transport outside municipal limits including all costs and carriages | 1,375.8 | Cum | - | - | - | - |
Tender Value
₹31.2 Cr
EMD Value
₹62.4 L
Closing Date
4 Jan 2020, 4:00 pmClosed
General Manager Projects
JKSICOP Head Office Jammu
Construction of Centre for training and Skill Development CTSD at JKEDI Campus Baribrahmna
2019_SICOP_87665_1
SICOP/GM (PE)/2019/01 Dated 09/12/2019
Open Tender
Civil Works
450 days
Baribrahmana Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
Account No 0116010100002211 IFSC code JAKA0GNGYAL
₹62.4 L
Yes
10 Jan 2020
9 Dec 2019
6 Jan 2020
9 Dec 2019
4 Jan 2020
9 Dec 2019
Amount
EARTH WORK
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50m and lift upto 1.5m in : All kinds of Soil:
Earth work in excavation by manual means over areas (Exceeding 30 cm and upto 1.5 mtr in depth, 1.5 mtr in width as well as 10 sqm. on plan) including disposal of excavated earth upto 1 mtr from cutting edge, disposed earth to be levelled and neatly dressed in : All kinds of Soil
Earth work in excavation in bulk by mechanical means (Hydraulic excavator) including disposal of excavated earth within complex or as directed by the Engineer-in-charge and disposed earth to be levelled and neatly dressed and consolidation with power road roller: All kinds of soil
Filling available excavated earth in trenches, plinth, sides of foundation incl ramming and watering
Supplying chemical emulsion in sealed containers i/c delivery as specified.: Chlorpyriphous / Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Along external walls where the apron is not provided using chemical emulsion @ 7.5 Ltr/sqm of the vertical surface of the substructure to a depth of 300 mm including excavation of channel along the wail & redding etc. with chlorophyilpros/ Lindane E. C 20% with 1% concentration
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 ltr/ linear mtr. including drilling and plugging holes etc.: with chlorophyriphos/ Lindane E.C. 20% with 1% concentration
Disposal of surplus excavated earth by mechanical transport outside municipal limits including all costs and carriages
Sand filling including levelling, watering, ramming and all carriage upto site of work.
P/L in position cement concrete of spcified grade excluding the cost of centring and shuttering -All work upto plinth level
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Reinforced Cement Concrete
Providing and laying in position machine· batched, machine mixed and machine vibrated -design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering, finishing and reinforcement, including Admixtures in recommended proportions, (as per IS 91 03) to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of Engineer-in-charge-M-20 grade reinforced cement concrete
All work upto plinth level
All work from plinth level upto Vth floor
Walls, columns, pillars, posts and struts.
Beams, plinth beams, girders, bressumers, centilevers, suspended floor lintels roofs and staircases including spiral staircases, shelves etc
Extra for R.C.C. work above floor V level for each four floors or part thereof.
Add or deduct for providing richer or leaner mixes respectively at all floor levels.
Providing M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing M-30 grade R.C.C. instead of M-20 grade R.C.C.(cement content considered in M30 is@ 340 kg/cum)
Centring and shuttermg including strutting, propping etc. and removal of form for
Foundations: footings, bases of columns etc. for mass concrete.
Wall ( Any Thickness) including attached pilasters, buttresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12mm thick
Lintel, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiralstaircases.
Extra for shuttering in circular work (20% of respective centring and shuttering items)
Edges of slabs and breaks in floors and walls. Under 20cms wide
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc including cost of de-shuttering and decentring at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be easured) : Suspended floors. roofs, landing, beams and balconies (Plan area to be measured).
Steel Reinforcement
Reinforcement for RCC work including straighting cutting,bending, placing in position and binding all complete. Cold twisted bars
Brick Work
Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 fine sand)
Extra for brick work in superstructure above plinth level upto Vth Floor (By manual means)
Extra for brick work in superstructure above floor V level for each four Floors or part there of (By manual means)
Extra for brick work with bricks of class designation 75 curved on plan upto a mean radius not exceeding 6metres.
Half brick masonry with bricks of class designation 75 in foundations and plinth in : Cement mortar 1 :4 ( 1 cement : 4 coarse sand)
Extra for half Brick masonry in superstructure above plinth level upto floor V
Extra for half brick work in superstructure above floor V level for each four Floors or part there of (By manual means)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
Stone Work
Providing and fixing 20mm thick Fiber reinforced cement conc exterior grade wall tiles with wire mesh clamp having weather proof coating set in 20mm thick cement mortar 1:3 mix and jointing with cement including cost of scaffolding upto floor 7th level and all carriages upto site of work.
Providing and fixing 18-20 mm thick Red sand stone premoulded and prepolished machine cut for external cladding, window sills , jambs, facias and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints in white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge complete at all levels including cost of scaffolding upto floor 7th level and all carriages upto site of work.
WOOD WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): 2nd class teak wood
Extra for additional labour for circular works, such as in frames of fan light 2nd class teak wood
Providing and fixing glazed shutters for doors, windows and clerestory windows using 10 kg/sqm (4mm thick) float glass panes including lSI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Ist class Kail wood 35mm thick
Providing and fixing 35mm wire gauze Shutters using galvanised M.S. wire gauze of avg width for aperture 1.4 mm in both direction with wire of dia 0.63 mm for doors, windows with hinges and screws. Ist class Kail wood
Providing and fixing lSI marked factory made flush door shutters , core of block board construction with frame of 1st class hard wood and well matched commercial ply with lamination of approved shade and two horizontal / vertical aluminum strip on both faces of shutters including cost of SS hutt hings. 40 mm thick.
Providing and fixing wooden moulded beading/architraves to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class Teak wood
Providing and fixing of side hand rail / grab bar fixed with PVC plug and wooden pegs incl chamfering of edges making of grooves and pattern as per drawings in Ist class local hard wood at various locations . 25mm x 150 mm
Providing and fixing 40x5mm flat iron hold fasts 40cm long including fixing to frame with 10mm dia bolts, nuts and wooden plugs and embedding in cement concrete blocks 30 x10 x 15 cm in 1:3:6 mix with 20mm nominal size stone aggregate.
Providing and fixing aluminium Tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete
Providing and fixing sliding door bolts lSI with marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete 300 x16 mm
Providing and fixing sliding door bolts lSI with lock ( L-drop) marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete Link, Godraj or equivalent. 300 x16 mm
Providing and fixing of aluminium anodised eye hooks 200 mm size
Providing and fixing aluminium hanging floor door stopper lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete. Twin rubber stopper
Providing and fixing aluminium handle lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete
Providing and fixing IS: 3564 marked Aluminium extruded section body tubular type universal hydraulic door closer,(having superior brand) embossed on the body door weight upto 36-80 kg and door width upto 700-1000 mm with double speed adjustment with necessary accessories and screws etc.complete
4mm glass
FLOORING
Cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, complete: 50mm thick with 20mm nominal size stone aggregate. (Crushed)
Marble flooring
Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer incharge) over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing. Pink plain marble
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete
Size of tile 60x60cm
Size of tile 80x80cm
Providing and fixing Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 13755 of NITCO, ORIENT, SOMANY, KAJARIA or equivalent make in colour such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick bed of Cement Mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 13753 ( miniumum thickness 5 mm ) of approved make in all colours, shades except begundy, bottle green, black of any size skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 and jointing with grey cement slurry
Granite flooring in floors, staircases treads and risers, landings, skirtings, counters and like with 18mm thick granite stone (sample of granite shall be approved by Engineer-incharge) over 20 mm (average) thick base of cement mortar 1:4 (1cement: 4 coarse sand) laid and jointed with grey cement slurry including moulding of edges, rubbing and polishing complete with:
Providing of double nosing (edge ) of granite sheet to required shape to achieve arch look in treads.
Granite stone work for wall cladding upto 4 m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.
Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in granite/ marble stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete
Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand). 25mm thick
Providing and Laying of cement concrete inter-lock pavement tiles 50mm thick layed over thick layer of fine sand
Ceiling
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanised with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide x1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastner 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G. I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick buttom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clips made out of 2.64mm dia X230 mm long G. I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws@ 230 mm interval, including fixing of gypsum board to celing section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers' specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with:
12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I.
Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer -in-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5mm thick with 8mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Providing and fixing plain Multipurpose Cement board ( High Pressure steam cured ) as per IS : 14862, with suitable screws for fibre cement board in ceiling etc. complete (frame work to be paid separately) : 6 mm thick cement board
Providing and fixing of khatamband with carving in budloo wood in false ceiling fixed on 12mm thick ply including framework in grids and polishing complete.
FINISHING
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 ( 1 cement: 6 fine sand)
12mm cement plaster on rough side of single or half brick wall of mix : 1:6 ( 1 cement: 6 fine sand)
12mm cement plaster on rough side of single or half brick wall of mix : 1:4 ( 1 cement: 4 fine sand)
6mm thick cement plaster 1:3 ( 1 cement: 3 fine sand)
Extra for plastering on circular work not exceeding 6 m in radius: In one coat
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface
Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade.
Applying priming coat on wood and wood based sufaces of approved brand and manufacture
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Finishing walls with textured paint of required shade and color of standard make on New work (two or more coats ) and a base coat of water proofing cement paint.
POP mouldings / cornice/ other patterns on flase ceilings/ walls / columns/ arches and curved surfaces etc.
Aluminum Partition and Curtain wall glazing
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion. Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
Providing and fixing 5mm thick toughen glass in aluminium sections for doors, windows and partitions etc including cost of beadings, EPDM rubber gasket required
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
Providing and fixing Aluminium Composite sheet cladding (exterior grade) in vertical / horizontal surface using 4mm thick sheet of approved make and colour. The sheet shall be bent to shaped profiles as required including Perimeter Extrusion base frame extruded stifferners 2.5 to 3mm, SS expansion fasteners and silicone sealant (Dow Corning 789),all back up arrangements required for installation as per approved Architectural Elevation drawings, complete in all respects.
WATER PROOFING
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and lying integral cement based water proofing trearment including preparation of surfaceas required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS.2645 and approved by Engineeer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortat of mix 1:5 (1 cement: 5 coarse sand) admixed with waterproofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3mm deep. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and final test. All above operations to be done in order as directed and specified by the Engineer-in-charge:
With average thickness of 120mm and minimum thickness at khurra as 65mm
STEEL WORK
Structural steel work welded in built up sections, trusses and framed work, including cutting,hoisting , fixing in position and applying a priming coat of approved steel primer all complete
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc.including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete,i/c fixing the railing with necessary accessories, balasters and stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
PLUMBING SANITARY FIXTURES & FITTINGS
Providing and fixing white vitreous china pedestal type water closet ( European type) with seat and lid , 10 litre low level white vitreous china flushing cistern and CP flush with fittings, C.I./ M.S. brackets 40mm bend diameter flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
W.C. pan with lSI marked white solid plastic seat and lid. with white vitreous china flushing cistern & C. P. flush bend.
Providing and fixing white vitreous china wall hung type water closet including concealed cistern along with push knob stainless steel flushing plate complete with all hardware/accessoris, solid plastic seat and lid, soft closing type and ablution jet complete
Providing and Fixing, testing & commissioning of ABS Health Faucet (complete with hook and flexible SS tube min. Length 1.0 m) as required.
Providing & Fixing first quality vitreous china oval/rectangula/ round (under counter) wash basin of following sizes for under counter mounting, specially fabricated fastners/ brackets, C.P brass chain & rubber plug 32 mm C.P brass waste and C.P brass cast bottle trap and pipe to wall with C.P brass flange and rubber adopter for waste connection complete including cutting and making good the walls wherever required. 560 x 400 mm size
Providing, fixing, testing & commissioning of C.P. brass eurometic self closing Pillar tap.
Providing, fixing, testing and commissioning of vitreous china large flat back Urinal with built in automatic sensor based flushing system. All other details as per item described above.
Providing & Fixing white glazed vitreous china urinal partitions of approved make including rawl plugs, screws or any other approved device for fixing arrangements, making holes in walls, floors & making good.
Providing and fixing toilet paper holder, C.P. brass
Providing and fixing brass bib cock of approved quality. 15 mm nominal bore
Providing and fixing C.P. brass close hole basin mixer piller tap of approved quality and make, weighing not less than 1.970 kg.
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved make conforming to IS : 8931
Providing and fixing uplasticised PVC connection pipe with brass unions.15 mm nominal bore 600 mm long
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing electrical gyser including all fitting accessories. Geyser of Capacity 35 ltr
Providing and fixing Salem Stainless Steel A lSI 304 (18/ 8) kitchen sink as per I.S. 13983 with C.l. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required: 610x510mm bowl depth 200mm
Providing,Fixing of 15 mm C.P brass wall mounted mixing fittings swinging spout for sink complete including cutting and making good the walls where required.
Single lever wall mixer with spout, adjustable OH shower with arm and wall flange complete with wall flange diverter assembly with Non-return Valves.
Providing & Fixing SS towel Ring of approved design and make
Providing & Fixing SS towel rail 600mm of approved design and make
Providing & Fixing looking mirror 5mm thick bevelled edge of approved make and desigh. Rectangular Shape 600x450mm
Providing & fixing of bath robe hooks made of brass, of approved make and design 3-4 hooks complete set
COLD / FLUSHING WATER SUPPLY (INTERNAL / EXTERNAL)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SOR 7.4 UV stablized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fitings 1/C fixing the pipe with clamps at 1.00m spacing. This includes cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. (Internal work exposed on walls)
PN-16 pipe , 32mm OD
PN-16 pipe , 40mm OD
PN-16 pipe , 50mm OD
PN-16 pipe , 63mm OD
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SOR 7.4 UV stablized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fitings 1/C fixing the pipe with clamps at 1.00m spacing. This includes cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. (concealed work including cutting chases and making good the walls etc.)
PN-16 pipe, 16mm OD
PN-16 pipe , 20mm OD
PN-16 pipe , 25mm OD
PN-16 pipe , 32mm OD
Providing & fixing PP-R ball valves of full flow of superior quality.
PN-16 pipe, 16mm OD
PN-16 pipe , 20mm OD
PN-16 pipe , 25mm OD
PN-16 pipe , 32mm OD
PN-16 pipe , 40mm OD
PN-16 pipe , 50mm OD
PN-16 pipe , 63mm OD
Providing and fixing Butterfly valve (upto 150mm dia with band lever operation & above with gear box operation) with SS-304 disc. Tested to a pressure not less than 15 Kg/sq.cm including rubber gaskets, flanges, nuts, bolts, washers & painting complete as required.
50 mm dia
65 mm dia
Providing, fixing, jointing and testing in position the following Heavy class G.I. pipes conforming to IS:1239 cut to required lengths including all necessary fittings (All fittings shall confirm to IS:1879 - part 1 to 10) and specials such as bends, tees, unions, reducers, flanges & plugs etc. fixing at wall / ceiling level supported by galvanized clamps, hangers etc as per specification or chasing in wall / floor and making good the same by using 1:1 cement mortar over the wire mesh. Threading, jointing and making proper connections. Cutting hole in wall / floor / slab and making good the same. Cost shall be inclusive of providing two coats of synthetic enamel paint of approved shade on exposed pipes, over a coat of primer, including painting of legends with direction around OR GI pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls / floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end as per directions
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
Providing & fixing full way lever forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
50 mm dia
Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid lSI license].
Supply, assembly, erection, testing and commissioning of SS submersible clear water pumps, suitable to transfer clear water (solid handling 10-12 mm) having capacity of 150 lpm against a total head of 60m with vortex impeller / grinder type, complete with 3 phase squirrel cage submerssible motor of required HP for 415 + 10% volts, 3 phase, 50 Hz. A.C. supply cooled by surrounding liquid, submersible cable upto main panel within the plant room, dry running preventor, G.I. guide pulling chain, all the necessary piping and accessories, valves, delivery header etc. as required complete in all respects. (Pumps for basement/pump room drainage)(1 working +1 standby) The installation shall be complete with sump pump lifting assembly, ready made electro – galvanized MS lifting chain, GI pipe header complete with discharge manifold, flanges, tee, elbow etc. complete including GI pipe upto the top of sump and including GI union. Header shall be sized for both pump working under delivery velocity of 1.5 m/sec.
Providing and fixing automatic water level controller with motor protection and overflow control.
INTERNAL DRAINAGE (SOIL, WASTE & VENT)
Providing and fixing, uPVC pipes 6 Kg/Cm2 (IS: 13592) including all fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointing with rubber ring/solvent cement joints including required suports,cutting chase or holes in walls and floors and making good where required.
Providing & fixing in position uPVC P"or S" trap of self cleaning design of following sizes for the embedded areas. Making proper connection with drip-seal joints, cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. 110 mm inlet and 110 mm outlet ( Make - Supreme / Prince / AKG )
Providing, fixing, testing and commissioning of pipe inlet fittings fabricated with P.P. Pipe with maximum 3 inlets 40, 50 & 75 mm OD size with Poloplast pipe OR by fixing Tee 110 x50/110 x75 mm (as required) fixed to 'P' traps for connecting fixture drains including fixing with drip seal / Pipe seal/ solvent weld joint / rubber ring joint as required complete.
Providing and fixing floor drain (FD) with 50mm/40mm outlet and one 40mm inlet for waste, with SS grating (adjustable height), having 50mm water seal and in-built NRV (McAlpine mrfg3 ).
Providing and fixing Heavy Class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT.
Providing and fixing stainless steel grating over the drain in bath room laid to sutaible slope leading into floor trap.
Providing and fixing CP brass grating with frame of approved design including setting in floor with cement motor to match with floor finish as per architect requirement.
Size 100 mm X 100 mm
Size 150 mm X 150 mm
Providing and fixing P.V.C. WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia PVC pipe / bend of required length and proper connection with M seal to C.I. pipe complete as required.
Providing, fixing and jointing UV stablised uPVC rain/waste water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cuting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects.
FIRE FIGHTING Fire Hydrants, Piping & Accessories
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of class 'C' M.S. pipes confirming to IS 1239 and 3589 including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/slabs and making good the same etc. complete in all respect as required.
100 mm dia
80 mm dia
Providing & fixing of heavy class M.S. pipes conforming to IS: 1239/3589 complete with fittings including trenching and refilling etc. (external work) including all fittings and accessories like tees, elbows, flanged joints, rubber insertion, nuts, bolts or cutting and welding joints. Providing thrust block at distance specified as per specifications. (Pipe shall be provided with anti corrosive protective treatment with coal tar/asphalt tape confirming to IS: 10221 standard complete as per specification). All work complete as per specification and as directed by Engineer-In-Charge.
150 mm dia
80 mm dia
Providing, Installation, Testing and Commissioning of double flanged cast iron Dual Plat Check Valve, PN 1.6 of following sizes confirming to IS : 5312 complete with EPDM rubber lining seat and stainless steel disc, rubber gasket, Gl bolts, nuts, washers etc. as required.
150mm dia
100mm dia
Providing of Cast Iron Non Rising Spindle Gate Sluice valve PN 16 (Flanged) rating hand wheel operated, stain less steel stem with gun metal parts, Nut, bolts & washers etc. complete as required as per specification conforming to IS:14846.
150mm Dia
Supplying of Butterfly valves of PN 1.6rating of following sizes with EPDM rubber lining seat and CF-8 stainless steel disc duly ISI marked and stainless steel stem with lever/gear operation and cast iron body in powder coated finish for fire fighting application complete in all respects confirming to IS: 13095 as required.
150mm dia
100 mm dia
65 mm dia
Supplying and fixing Single Headed Internal Hydrant Valve oblique pattern with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked, conforming to IS : 5290 (Type A), with 80 mm dia flanged inlet, with ABS cap and chain complete with all accessories etc. as required.
Supplying and fixing ISI marked single headed external hydrant valve with instantaneous stainless steel of 63 mm dia with cast iron wheel ,conforming to type "A" of IS:5290 with blank ABS cap and steel chain etc complete as required.
Supply, Installation, Testing and Commissioning 63 mm dia. 15 Mtr. Long RRL hose pipe with 63 mm dia. male and female stainless steel couplings duly binded with GI wire rivets etc. ISI marked, IS 636 (type-A) as required.
Supplying and Fixing First Aid Hose Reel, wall mounting swinging type complete with drum & bracket of MS construction, spray painted in Post office Red, confirming to IS 884/1995 with upto date amendments, complete with the following as required. 30 Mtr Long 20 mm nominal internal dia as per IS 12585 water hose thermoplastic (Textile reinforced)Type II, 20 mm dia. ball valve & nozzle., Drum and brackets for fixing the equipments on wall, Connection from riser with 25 mm dia gun metal stop valve and M.S pipe as reqd.
Supplying and fixing Stainless Steel branch pipe with 20mm dia nozzle conforming to IS:903. suitable for instantaneous connections to hose pipe coupling etc. as required.
Supplying and fixing of weather proof hose cabinet of size 900 mm x 600mm x 500mm made of 2mm thick MS sheet with 6mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 nos. 15 mtr. Long Hose Pipe, 1 No. branch pipe, mounted on wall or raised brick platform & duly painted with Post office red externally and White internally with Synthetic enamel paint complete in all respect, for external hydrant, as required.
Supplying and fixing 2 way FBC of CI body with 3 no. Stainless Steel male instantaneous inlet couplings complete with cap and chain as required. For 150mm dia M.S Pipe connection conforming to IS: 904 as required.
Providing,fixing,testing and commissioning of one number Stainless steel fire brigade section hose coupling (Fire brigade withdrawal connection) i/c foot valve in the bottom etc. as per specification complete as required. (M.S pipe of 100 mm dia will be paid in pipe item.
Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia Stainless Steel wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Providing,fixing,testing and commissioning 100 mm dia pressure gauge of range 0 -015 Kg / sqcm conforming to IS - 3624 having bourdon tube of stain steel 310 in cast aluminium,stove enamelled, black, weather proof case with outer, screwed aluminium bezel and complete with necessary U-type stainless steel siphon tube and cock complete as required.
Supplying, installation, testing and commissioning of M.S cabinet size 1000 mm x 2100 mm x 600mm deep fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements.
FIRE EXTINGUISHERS & MISC
Providing and fixing with bracket/supports etc. wall mounted fire extinguishers as per detail below:
Providing and fixing water based CO2 type extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:934 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. Capacity 9 lit.
Providing and fixing fire extinguisher of water srored type extinguisher with cylinder fully charged with 6ltr capacity.
ABC Modular Type Fire Extinguisher 9 Kg capacity filled with MAP 70% ABC Powder complete in all respect.
Internal Electrical installation & street lights (with conduting for telphone and other Services) POINT WIRING
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required - Group C
Wiring for light/power plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 No.4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required (for power plugs & UPS outlet).
Wiring for light/power plug with 4 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 2 Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required (for power plugs & UPS outlet).
Wiring for circuit / submain alongwith earth wiring with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed in suitable size of steel conduit as required.
2 x 1.5 sq.mm + 1 x 1.5 sqmm earth wire (For circuit wiring)
4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire
6 X 1.5 sq. mm + 3 X 1.5 sq. mm earth wire
2 x 6 sq. mm + 1 x 6 sq. mm earth wire
4 x 6 sq. mm + 2 x 6 sq. mm earth wire
4 x 10 sq. mm + 2 x 10 sq. mm earth wire
4 x 16 sq. mm + 2 x 16 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel / PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (for Circuit / CCTV / Telephone/LAN/ Nursecall System / Fire alarm )
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
TV antenna socket outlet
Supplying and Fixing following sizes / modules , GI box along with modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75 mm X 75 mm) For Switch, Telephone, TV and LAN
Supplying and fixing following Modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing brass batten / angle holder including connection etc. as required.
Supplying and fixing call bell/buzzer suitable for single phase, 230 volts, complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
SUPPLY AND INSTALLATION OF FAN & LIGHT FITTING
Supply of energy efficient 1200MM ceiling fan of white colour (But with-out regulator) capacitor type complete with 30 cm down rod , canopies, hanging shackle, i/c pdg & fixing phenolic laminated sheet cover in the fan box, blades, double ball bearing type (Energy Saver - 5 star rating ) suitable for use on 220/240 volts, 50Hz single phase A.C. supply i/c wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper condutor, single core cable etc. as required.
Supply of energy efficient wall fan including installation arrangment (Energy Saver - 5 star rating ) suitable for use on 220/240 volts, 50Hz single phase A.C. supply
Supply, Installation, Testing and Commissioning of 13Watt LED down lighter with minimum 1200 Lumen output with latest LED technology and reliable heat managment to deliver a long lasting efficient complete with constant driver, internal wiring etc as require.
Supply, Installation, Testing and Commissioning of 18Watt LED down lighter with minimum 2000 Lumen output with latest LED technology and reliable heat managment to deliver a long lasting efficient complete with constant driver, internal wiring etc as require.
Supply, Installation, Testing and Commissioning of 600mm x 600 mm LED recess type fitting with minimum lumen output 3300 lumen and luminar's lumen output / wattage should not be less than 85 with all accessories directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required.
Supply, Installation, Testing and Commissioning of 300mm x 300 mm LED recess type fitting with minimum lumen output 3300 lumen and luminar's lumen output / wattage should not be less than 85 with all accessories directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required.
Supply, Installation, Testing and Commissioning of 1 x 28Watt TL'5 wall / surface mounted light fixture complete with 28watt tube, Constant Ballast, connection etc as required.
Supply, Installation, testing & commissioning of 1x9watt LED bulkhead surface mounted light fixture complete with driver etc as required.
Supply, Installation, Testing and Commissioning of 1 x 54Watt recess mounted1200mm LED fitting with minimum lumen output / wattage not be less than 85 with all accessories directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required
DISTRIBUTION BOARDS & DB's
Supplying, testing, installation and commsioning of surface/ recess mounting, double door vertical type, 415 Volts, TPN MCB Distribution board of sheet steel, dust protected, duly phosphatised and powder painted, inclusive of 250 Amps tinned copper bus bar, common neutral link, earth bar, tin bar for mounting MCB's detachable gland/ knock out plate suitable for 100 to 160 Amp MCCB as incomer interconnection between incomer MCCB and bus bar of following ways (But without MCCB, MCBs) as required.
4 way double door (IP-43)
6 way double door (IP-43)
12 way double door (IP-43)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40Amp 4P MCB 'C' Curve 10 KA
63Amp 4P MCB 'C' Curve 10 KA
Supplying and fixing TP, 415 volts, 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40Amp TP MCB 'C' Curve 10 KA
63Amp TP MCB 'C' Curve 10 KA
Supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
LIGHTNING PROTECTION
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper / G.I. tape, base of the finial or any other mettalic object) by riveting / nut bolting / sweating and soldering etc as required.
Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required (For horizontal run)
Providing and fixing GI tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required. (for vertical run).
Providing and fixing testing joint, made of 20mm x3mm thick GI strip, 125mm long, with 4 nos. of GI bolts, nuts, check nuts and spring washers etc. complete as required.
Providing and laying GI tape, 32mm x 6mm thick, from earth electrode directly in ground as required.
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long with charcoal / coke and salt as required.
ADDRESSABLE FIRE ALARM SYSTEM AND DIGITAL VOICE EVACUATION AND 2-WAY COMMUNICATION SYSTEMINTELLIGENT ADDRESSABLE FIRE ALARM SYSTEM
Supply, Installation, Testing & Commissioning of Microprocessor based 10 loop capacity , Networkable Analogue Addressable type Fire Alarm Control panel.The FACP shall have minimum 640 character Display with fully functional QWERTY Keypad. Each loop shall have a maximum loading of 159 detectors and 159 devices . Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and for 2 hours during an emergency conditions as required. The FACP shall be UL 9th Edition Listed. FACP should be integrated with Digital Voice Controller with capacity to communicate and transmit pre-recorded and paging messages through the Digital Audio Amplifiers distributed across various floors of the building on a Digital Audio Loop with zone control function and other accessories required to complete the system. The System shall have capability to connect Fire Fighting Phone and Telephone Phone Jacks . FACP and Digital Voice Controller should be with Network Communication Module with true peer to peer Connectivity. Failure of Fire Alarm Panel CPU shall not result in failure of operation of Amplifiers. Hence if the Digital Audio Amplifiers are CPU Rail Mounted, consider 1 No. CPU dedicated for Digiital Audio Amplifier Bank.
Supply, installation,testing and commisioning of The LCD indicator panel is used as an add-on device for the remote display of FACP status information of the FDA operating front relating to detectors and detector zones. Event messages are displayed via LED collective indicators and on the 4-line minimum 80 Alpha Numeric LCD display with the associated detector zone number and a programmable additional text. Each message is signalled via the built-in buzzer. The buzzer can be acknowledged by pressing a button. Up to 31 LCD indicator panels can be operated on an RS 485 bus .
Supply, installation,testing and commisioning of Repeater Panel: Central remote Indicator in aesthetic Surface Mounted Housing as additional Display for Fire alarm System. Actuaation is made over Serial Interface of FACP . Plain Text Msg - 2 x 20 Characters with 2000 programmable texts. It should have provision to connect upto 31 such Repeaters over single Panel .
Supply, Installation, Testing & Commissioning of Analog Addressable type Self Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting base, LED, Address Switch, complete with MS Powder coated Junction Box for mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends, cable compression glands, cable tags and Ferruling. (BFC)
Supply, Installation, Testing & Commissioning of Response Indicator with matching screws complete with GI Junction box, Cable lugs at cable end and ferruling.
Supply, Installation, Testing & Commissioning of Addressable Dual Action Manual Pull Station with Adddress Switch and all mounting accessories , complete with MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Supply, Installation, Testing & Commissioning of Addressable Monitor Module with Adddress Switch and all mounting accessories, complete with MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Supply, Installation, Testing & Commissioning of Addressable Relay Module with Address Switch and all mounting accessories complete as required. Shall be complete with Pilot Relay for Tripping of Third Party Equipment, suitable for switching 5A/15A current through the Relay contacts , MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Supply, Installation, Testing & Commissioning of Addressable Control Module with Address Switch and all mounting accessories, complete with MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Supply, Installation, Testing & Commissioning of Fault Isolator Module , complete with MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Supply, Installation, Testing & Commissioning of Directional Sounders with 20Hz to 20 KHz operating frequency with minimum 8 distinct sound patterns to indicate Exit doors and direct occupants for safe and fast evacuation , complete with MS Powder coated Junction Box for mouting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Supply and drawing of 2c x 1.5 sq.mm copper cable, 2 cores twisted together, armored, such that the cable retains Circuit Integrity for minimum 2 hours at a service voltage of up to 1000V under SIMULTANEOUS ACTION of flame at 950°C, Mechanical Shocks and Water Stress with all these 3 being performed on the same cable sample. The cable should also have Light Transmittance as per IEC-61034. 3rd Inspection report shall be submitted with every Lot.
DIGITAL VOICE EVACUATION AND 2-WAY COMMUNICATION SYSTEM
Supply, Installation, Testing & Commissioning of Ceiling Mounted Voice Evacuation Speaker having power taps upto 2W and frequency response of 400 to 4000Hz for Voice Evacuation.
Supply, Installation, Testing & Commissioning of Wall Mounted Muli-Candela Strobe cum Hooter with all required accessories for mounting complete as required.
Supply, Installation, Testing & Commissioning of Digital Audio Amplifier capable of processing one of 8 audio channels and total of 50W at 70.7 VRMS output along with necessary enclosures. The DAA shall be fully monitored for fault and alarm reporting. The proposed Digital Amplifiers shall not be rail mounted / dependant on Fire Panel CPU for operation. (Failure of Fire Panel CPU shall not result in failure of Amplifier operation).
Supply, Installation, Testing & Commissioning of Power Supply Unit - 240VAC to 24VDC - 6Amps. Power Supply shall be UL Listed with Necessary Battery Backup.
Supplying, laying and fixing of following size of unarmoured, twisted copper flexible FRLS cable in existing surface / recessed in suitable size of steel conduit complete with all accessories as required.
2 C X 1.5 Sq mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
SUB PANELS LIFT PANEL - 1
Supplying, installation, testing & commissioning of cubical type wall mounted motor control L T panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 315 Amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MV A for I Sec. with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, i/c additional NO/NC contacts in all outgoing starters for automatic operation through BMS and providing & fixing following switch gears:-
Incoming:
4 pole 125 Amp. Auto matic transfer Switch with CI 1000 contactor - 1 Set
3 Pole MCCB 125 Amp (lcs=I cu) 25 KA, with phase spreader links and barrier, Solid neutral link - 1 Set
3 Nos. Phase indication LED lamps with 2Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB,
Outgoings:
3 Pole MCCB (lcs=Icu), with phase spreader links and barrier , Solid neutral link
63 Amp MCCB - 25 KA - 3 Nos.
LIGHT PANEL
Supplying, installation, testing & commissioning of cubical type wall mounted motor control L T panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 315 Amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MV A for I Sec. with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, i/c additional NO/NC contacts in all outgoing starters for automatic operation through BMS and providing & fixing following switch gears:-
Incoming:
4 pole 400 Amp. Auto matic transfer Switch with CI 1000 contactor - 1 Set
3 Pole MCCB 125 Amp (lcs=I cu) 25 KA, with phase spreader links and barrier, Solid neutral link - 1 Set
3 Nos. Phase indication LED lamps with 2Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB,
Outgoings:
3 Pole MCCB (lcs=Icu), with phase spreader links and barrier , Solid neutral link
100 Amp MCCB - 25 KA - 10 Nos.
POWER PANEL
Supplying, installation, testing & commissioning of cubical type wall mounted motor control L T panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 315 Amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MV A for I Sec. with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, i/c additional NO/NC contacts in all outgoing starters for automatic operation through BMS and providing & fixing following switch gears:-
Incoming:
4 pole 630 Amp. Auto matic transfer Switch with CI 1000 contactor - 1 Set
3 Pole MCCB 125 Amp (lcs=I cu) 25 KA, with phase spreader links and barrier, Solid neutral link - 1 Set
3 Nos. Phase indication LED lamps with 2Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB,
Outgoings:
3 Pole MCCB (lcs=Icu), with phase spreader links and barrier , Solid neutral link
125 Amp MCCB - 25 KA - 10 Nos.
EXTERNAL LIGHTING PANEL
Supplying, Installation, Testing and Commissioning of dust, damp and vermin proof free floor standing mounted factory built sheet steel enclosed modular construction extendable panel, suitable for operatrion on 415 + 10% volts, 50 Hz AC 3 phase 4 wire system fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with aluminium bus bars, interconnection with solid copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per drawing and technical specifications attached etc. complete as required.
INCOMING :
1 No. of 125 Amp 4P MCCB of 25 kA Breaking capacity.
1 No. Intelligent multifunction digital panel meters of class 1.0 accuracy with communication interface port RS 485 for recording V (Between Phases and between each phase and neutral), A (In each phase and neutal), KWHr with suitable rating CTs, CT shorting links, R,Y,B LED indicating lamp and 2 A control SP MCB's.
BUSBAR:
150 Amp. TPN Al. Bus Bar
OUTGOING
16 Amp DP MCB 10 KA - 10 Nos.
20Amp. Industrial socket with MCB (IP 66) - 1 No.
Sutiable size of DP Contactor with NO/NC Contacts -1 No.
24 Hour Timer - 1 No.
SAFETY EQUIPMENTS
Providing & fixing danger plates made of mild steel at least 2 mm thick & vitreous enameled white on both sides & with inscriptions in signal red colour on front side as reqd.
High Voltage- Size 250 mm x 200 mm
Medium Voltage- Size 200 mm x 150 mm
Supply and fixing safety instruction chart in word duly framed with 5 mm thick glass as required. (approx front area 1.20 sq.mt).
Providing of set of 3 Nos 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint FIRE and mounted on 50 mm x 50 mm x 6 mm thick MS angle iron frame of appropriate size i/c filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS 2217 : 1963.
Supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as reqd (approximate front area 1.20 sq.metre)
Fabrication supplying & fixing of 10 mm thick M.S. chequired plate in cutting welding including 2 no M.S. handle for lifting, painting with black paint etc. as required.
Supplying and fixing of M.S. frame made out 50x50x6 mm thick M.S. angle including cutting welding and grouting with 1:2:4cc etc. complete as required.
Providing of rubber mat 1 mtr.x 2 mtr and 12.50 mm thick to withstand 15 KV dielectic strength as per IS 15652:2006 blake or red complete etc as reqd with text cerfified.
EARTHING
Earthing with GI earth place 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connection etc. as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25mm X 5 mm G.I. strip on surface or in recess for connections etc, as required
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 50mm X 6 mm G.I. strip on surface or in recess for connections etc, as required
Supply, making end termination with copper lugs for following sizes of PVC sheathed copper conductor unarmoured cable of 1.1 KV grade on existing cable tray / surface including saddle, clamps etc. complete as required.
1C X 25 Sqmm. Copper unarmoured cable
CABLE & CABLE TRAYS
Supply of following sizes of XLPE insulated PVC sheathed aluminium conductor armoured cable of 1.1 KV grade on existing cable tray / surface including saddle, clamps etc. complete as required.
4 Core X 6 Sqmm.
4 Core X 10 Sqmm.
4 Core X 16 Sqmm.
4 Core X 25 Sqmm.
3½ Core X 35 Sqmm.
3½ Core X 50 Sqmm.
3½ Core X 70 Sqmm.
3½ Core X 95 Sqmm.
3½ Core X 120 Sqmm.
3½ Core X 150 Sqmm.
3½ Core X 185 Sqmm.
3½ Core X 240 Sqmm.
3½ Core X 300 Sqmm.
Supplying and making end termination with brass compression glands and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.
4 Core X 10 Sqmm.
4 Core X 16 Sqmm.
4 Core X 25 Sqmm.
3½ Core X 35 Sqmm.
3½ Core X 50 Sqmm.
3½ Core X 70 Sqmm.
3½ Core X 95 Sqmm.
3½ Core X 120 Sqmm.
3½ Core X 150 Sqmm.
3½ Core X 185 Sqmm.
3½ Core X 240 Sqmm.
3½ Core X 300 Sqmm.
Supply, and making end termination with copper lugs for following sizes of PVC sheathed copper conductor unarmoured cable of 1.1 KV grade on existing cable tray / surface including saddle, clamps etc. complete as required.
1C X 25 Sqmm.
Fabricating and installing follwoing size of ladder type M.S. cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenderes and icnluding painting with powder coating etc. as required:
100 mm. Width x 50mm Depth x 1.6 mm Thickness
150 mm. Width x 50mm Depth x 1.6 mm Thickness
300 mm. Width x 50mm Depth x 1.6 mm Thickness
450 mm. Width x 62.5mm Depth x 2.0 mm Thickness
600 mm. Width x 75mm Depth x 2.0 mm Thickness
750 mm. Width x 75mm Depth x 2.0 mm Thickness
900 mm. Width x 75mm Depth x 2.0 mm Thickness
Laying of one number PVC Insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq.mm
Above 35 sq.mm and upto 95 sq.mm
Above 95 sq.mm and upto 185 sq.mm
Above 185 sq.mm and upto 400 sq.mm
Laying of one number additional PVC Insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq.mm
Above 35 sq.mm and upto 95 sq.mm
Above 95 sq.mm and upto 185 sq.mm
Above 185 sq.mm and upto 400 sq.mm
Laying of one number PVC Insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC / HUME / METAL pipe as required.
Upto 35 sq.mm
Above 35 sq.mm and upto 95 sq.mm
Above 95 sq.mm and upto 185 sq.mm
Above 185 sq.mm and upto 400 sq.mm
Laying of one number PVC Insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq.mm
Above 35 sq.mm and upto 95 sq.mm
Above 95 sq.mm and upto 185 sq.mm
Above 185 sq.mm and upto 400 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on open duct / cable tray as required.
Upto 35 sq.mm (clamped with 1mm thick saddle)
Above 35 sq.mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp)
Above 95 sq.mm and upto 185 sq.mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq.mm and upto 400 sq.mm (clamped with 40x3mm MS flat clamp)
Providing, laying and fixing following dia RCC pipe NP 2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep)and refiling etc as required.
150 mm dia
250 mm dia
300 mm dia
Passenger Lift
Supply, Installation, Testing & Commisioning of 13 Passenger lift (1000Kg) electric traction, without machine room having contract speed of 1.0 Meter per second serving different floors in the lift shaft of size 2050mm (W) x 2500mm (D), 1600 mm pit depth and 4200 mm / 4800 overhead as per detailed specifications attached and as under complete with all the equipement and accessories.
Floor Height - 4.10 meter
Number of Landings (i.e. Stops) - Ground Floor + 6 Floors = 7 Floors
Travel Height - 30.0 Meter (approx.)
No. Of Openings - 7 Stop & 7 Opening (all opening be on same side)
Drive System & Control - Alternating Current Voltage Frequency (ACVF) with Closed Loop system with Gealess Motor
Automatic Rescue Device (ARD) compete with dry maintenance free batteries as required.
Power: 415 Volts+10%, 3 Phase 4 wire 50 Hz AC system.
Car Enclosure: Car Size ( WxDxH) - As per the Indian Standard Codes. Car height shall be minimum 2100mm Car door (Height x Width)mm -(2000 x 900 )mm Minimum Must be Fully Automatic Power operated, central opening, horizontal sliding stainless steel scratch resistant SS finish
Car Ceiling - SS- Finish Hairline
Car Walls & Doors Finish - SS - Finish (Scratch resistant) on all sides.
Car Floor - Granite Flooring
Mirror - All the three side
Sill - Aluminium profiles
Car Operating Panel - To Be furnished by the tenderer
Car Lighting - Minimum 50 lux on floor and on Car operating Panel.
Handrail - SS Finish on the rear wall and not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.
Car Walls - Minimum 6mm Thick
Decoration Skirting & Corners - Must be Anodised for weather protection
Recess Flooring (for Owners) - 25mm
Landing Doors: Fully Automatic Power operated, central opening, horizontal sliding MS Doors with powder coating of approved shade.
Landing Door Size (WxD) mm - Minimum 900 (Width) x 2000 (Height)
Control & Fixtures Details -
Landing display - 16-segment Car position and direction of travel display and Lift under maintenance display
Emergency Alarm - Alarm with Rechargeable Sealed Maintenance Free batteries.
Over load warning - Audio/ Visual Overload warning indicator to be provided.
Voice Synthesizer in car - Floor and door open/close Voice Announcement
Car Display - 16-segment LED Dynamic Car Direction display & Digital position indicators
Infra-red Light Curtain (Full Length) on Car doors - To be provided
Auto Light/Fan Cutoff - Ventilation fan ON OFF switch with auto switch off feature
Door open/ Door Close - Door open and Door Close buttons with Symbol markings.
ARD operation Audio / Visual indication in car - To be provided
Emergency Alarm Button - Emergency Alarm button with Bell symbol & the same should be at a distinct distance from the call buttons.
Intercom - To be provided (i.e. 3-way intercom)
Hall Buttons - To be provided as per the Tenderer
Out of Service Mode - To be provided
Attendant Operation - To be provided
Machine Power Supply -3 x 415V /220V, 50 Hz
Acceptable Voltage Fluctuation - +10% to -15%
Acceptable Frequency Fluctuation - +/- 5%
Rate of Acceleration/Deceleration M/s2 - < 0.5 meter per second square
Jerk( m/sec3) - < 1 meter per second cube
Horizontal Vibration X/Y (mPtP) - < 15mg (As per ISO 18738)
Vertical Vibration Z - < 25 mg (As per ISO 18738)
Airborne Noise Levels - 50 ± 3 dBa
Airborne Noise level in Car (without Fan) - Max 60 dBa
Airborne Noise level in front of closed Hoistway door (when car passing by) - Max 53 dBa
Stopping Accuracy - ± 3mm
Elongation - ± 20mm
Leveling Accuracy - ± 10mm
Door Drive - Compact VVVF closed loop
Car panel & Door panel thickness - Atleast 1.6 mm
Maximum Number of trips Per Hour - < 180
Safety Features & Other Inclusions
Door Protection - Multi beam infrared protection device so as to reverse the closing door in case of slight obstruction in the door way.
Anti nuisance - To Be provided
Fire Man Control - To Be provided
Over Load detection Device - To Be provided
Buffers - Spring Buffers
Safety Governor - Electro-Mechanical type Safety governors for Car.
Safety Instructions - Do’s & Don’ts with emergency contact Numbers must be provided & displayed in the car
Over travel protection - Terminal and final limit switches to be provided.
Controller / Drive / Motor Protection - Trip Device for Over current, Under Voltage and Over voltage than the rated capacity. + 10%
· Motor overload / over torque
· Instantaneous over current
· Ground fault
· Under voltage
· Over voltage – 3 phase
· Output & Input phase loss
· Phase reversal
· Output short circuit
· Over speed
· Spikes & Surges
Protection with the Sudden surges/spikes in level in voltage alongwith shifting of neutral and earth leading to improper earthing (Must be provided as a separate kit.)
ARD (Automatic Rescue Device) - ARD to be provided. (Detailed Literature of Make and working of ARD to be provided separately).
Fire Rating of Landing doors - Landing doors must have 2 hour fire resistance rating and Elevator supplier must provide the Fire-certificate for the same from Accrediated laboratory.
Self adjustment & self Daigonastic - To be provided
Intercom connection - Must be provided in 3-way
Fascia Plates & Sill angles - Full height Fascia Plates and Sill angles to be provided (or as per the IS Code Guidelines)
Pit Ladder - MS Pit ladder to be provided and securely fastened inside the pit.
Counter Weights - In case of non-metallic filler weights, the counterweight sections shall be totally enclosed in a metallic covering.
Major Components Service Life:-
· Ropes / Belts :- 8 years
· Over speed governor:- 20 years
· Traction machine /motor:- 20 years
· Door operator:- 20 years
· Safety gear / block :- 25 years
· Travelling cables:- 20 years
· Inverter Drive:- 20 years
· Buffer:- 20 years
Voice Announcement - Voice announcement to announce the Floor position as well as door open/door close. Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.
Infra-red Light Curtain (Full Length) on Doors - To be provided - Multi beam infrared protection device so as to reverse the closing door in case of slight obstruction in the door way.
EQUIPMENTS VRF Outdoor Units
Supply, Installation, Testing and Commissioning of Variable refrigerant flow type air-conditioning system suitable to operate at 415 ± 10% volt, 50 Hz,3 phase AC power supply for cooling/heating with compressors (Hermetically sealed scroll type) complete with fittings including full charging of R-410A refrigerant gas complete as per requirement.
60 HP (3 x 20 HP per circuit)
48 HP (3 x 16 HP per circuit)
40 HP (2 x 20 HP per circuit)
32 HP (2 x 16 HP per circuit)
8 HP (FOR TFA)
VRF Indoor Units Cassette Unit
Supply, Installation, Testing and Commissioning of 4-way flow type Cassette Units of following capacity with fittings, controller,drain pump, panel, complete as required.
Treated Fresh Air Unit (TFA) Supply, Installation, Testing and Commissioning of ceiling suspended type Treated Fresh air unit of the following capacities as specified and shown in drawings complete with the following :-
1000 CFM (6.4 TR,8HP)
Air Handling Unit
Supply Installation testing and Commissioning of Air Handling Unit with Double Skin Floor Mounted with DX Coil Double Circuit with three phase motor and including AHU Connecting Kit with VRF ODU EEV & Commnication as per Specification.
10000 CFM 65 mm SP 25 TR
Controller
Supply, installation, testing and commissioning of touch screen controller (Which is controlled 64 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls.
Y-Joints
Supply,Installation, Testing and Commissioning of Y-joints for various pipe sizes and headers etc.
Supply,Installation, Testing and Commissioning of Cordless / Corded remotes
Refrigerant Piping
Supply, Installation and testing of refrigerant interconnecting piping inside and outside the building (thickness of 0.8 mm for soft pipe and 1.0 mm for hard pipe including circuit of liquid & suction) insulated with 13 mm / 19mm thick closed cell nitrile rubber complete.
41.3 mm dia
34.9 mm dia
28.5 mm dia
22.2 mm dia
19.05 mm dia
15.8 mm dia
12.7 mm dia
9.5 mm dia
6.3 mm dia
Drain Piping
Supply, Installation and Testing in position the following UPVC condensate drain pipe (suitable for minimum 6kg/sq cm working pressure) insulated with 6 mm thick insulation as per required .
50 mm dia drain pipe
32 mm dia drain pipe
25 mm dia drain pipe
AIR DISTRIBUTION WORK
Supply, installation, balancing and commissioning of site fabricated GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
24 Gauge
22 Gauge
Supply, installation, testing and commissioning of extruded aluminium powder coated supply air grills with damper of approved shade and make as per specifications including any framework required for fixing .
Supply, installation, testing and commissioning of extruded aluminium powder coated return air grills without damper of approved shade and make as per specifications including any framework required for fixing .
Supplying, Fixing, Testing and Commissioning of supply air diffusers ( 150 x 150 mm Size) of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supply, Installation and testing of fresh air arrangment including insulated flexible duct of 2 mtr. lenth of 100 mm dia
Supply , Installation , Testing and Commissioning of extruded aluminum louvers with bird screen and volume control damper for fresh air intake in indoor units.
INSULATION
Supplying and fixing of following thickness closed cell Nitrile rubber (class ''O'') insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50mm wide and 3 mm thick self afhesive nitrile rubber tape insulaton complete as per specifications and as required.
9 mm thickness
Supplying and fixing of following thickness XLPE (Cross linked polyethylene ) with foil for underdeck insulation after applying two coats of cold setting adhesive Complete as per specifications and as required.
12mm Thickness
ELECTRICAL FOR HVAC
CONTROL & TRANSMISSION WIRING
Supply, installation, testing and commissioning of 2 Core x 1.5 mm copper Shield wire in PVC conduit as per specifications for transmission
Supply, installation, testing and commissioning of 2 Core x 1.0 mm copper wire in PVC conduit as per specifications for remotes
Supply, installation, testing and commissioning of 3 Core x 1.5 mm copper wire in PVC conduit as per specifications for connecting indoor units with AC Mains
VRF ELECTRIC PANEL
Supplying, installation, testing & commissioning of cubical type wall mounted motor control L T panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 315 Amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MV A for I Sec. with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, i/c additional NO/NC contacts in all outgoing starters for automatic operation through BMS and providing & fixing following switch gears:-
Incoming:
1No 4 Pole MCCB 630 Amp (lcs=I cu) 36 KA,
3 Nos. Phase indication LED lamps Digital AVF meter
800Amp TPN Aluminium busbar - 1set
Outgoings:
8Nos. 4 Pole 80 Amp RCCB 300 mA (lcs=Icu),
MS Anil Kumar Kapahi Contractor
S K Integrated Consultants
MS ABRAQ INFRASTRUCTURES LLP
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
SBDmergedFinal.pdf
Tender Documents • 5.13 MB
BOQ_163991.xls
BOQ • 1.00 MB
Download all tender documents and submit your bid