Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | L1 | Accepted-AOC The lowest bidder. | |
| 2 | L2₹30.8 L+₹1.3 L (4.23%)Rejected-AOC | L2 | Rejected-AOC Other than the lowest bidder | |
| 3 | L3₹31.3 L+₹1.8 L (5.97%)Rejected-AOC GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-AOC Other than the lowest bidder | |
| 4 | L4₹34.4 L+₹4.8 L (16.3%)Rejected-AOC 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L4 | Rejected-AOC Other than the lowest bidder | |
| 5 | L5₹37.0 L+₹7.5 L (25.2%)Rejected-AOC 93 618 A MOHANTA PARA WARD NO 19 PO DIST JALPAIGURI PIN 735101 | JALPAIGURI | WEST BENGAL | 735101 | L5 | Rejected-AOC Other than the lowest bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
27 Dec 2023, 6:00 pmClosed
COMMANDER WORKS ENGINEER
Commander Works Engineers (Sub) Military Engineer Services PO Barrackpore, Dist 24 Pgns (N) Kolkata 700120 (W.B)
REPAIR AND MAINT OF HT SWITCH GEAR, VCBS, TRANSORMERS, AB SWITCHES, 2-4 POLE STRUCTURE, HT CABLES AT BARRACKPORE UNDER GE BARRACKPORE
2023_MES_631619_1
CWE/BKP/31 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BARRACKPORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE BARRACKPORE
₹78,000
Yes
10 Feb 2024
7 Dec 2023
29 Dec 2023
7 Dec 2023
27 Dec 2023
21 Dec 2023
Amount
Supply and fix in repairs HT bus bar with insulators as suitable for existing rating current in three phase with proper moisture proof with nuts, bolts and washer and suitable lugs with proper crimping and adequate clearance between the bus bar and earth and any fabrication as required as per site conditions by the contractor at its own cost
Supply and fix in repairs 11 KV HT VCB operating mechanism with motor operated spring charged system assembly including coil assembly with 24 Volts DC auxiliary supply system works satisfactorily and testing complete all as specified and directed
Supply and fix in repairs manual charging of closing spring and emergency hand trip assembly and testing complete all as specified and directed
Supply and fixing in repairs of 11 KV HT CTs( Primary and secondary) as per existing suitable ratio, whether wound ring or bar type with complete settings with relay, short circuit instrument, earthfault instrument ,metering equipment with transformer ratio adjustment with burden,accuracy and Overhauling of primary injection by artificial load through CT's & secondry injection of over current earth fault relays/release on each multipule setting readjustment and testing comlete all as specified and directed
Supply and fix in repairs of 11 KV PT's both ( Primary and secondary) and apply multi grease for mechnical parts, inspecting HT bushing male and female and apply dry graphite conductive sealant for contacts,replaced damaged insulators and testing, and assembling, allienemts of components and testing complete all as specified and directed.
Supply and fix in repairs of 11 KV HT contact assembly such as auxillary contactor(2 No+2NC) with burnt coil and all accessories and checking of electrical wiring system,and testing complete all as specified and directed.
Supply and fix in repairs phase indication 'RYB' neon lamps with all connected accessories and including 9w LED lamp at inside of the VCB with electrical wiring system and testing complete all as specified and directed.
Supply and fix in repairs tripping shaft assembly with coil and including springs,strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed.
Supply and fix in repairs closing shaft assembly with coil and including springs, close strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed.
Supply and fix in repairs vaccum interrupter bottles assembly and connected accessories for functional requirement and checking of electrical wiring system and testing complete all as specified and directed.
Supply and fix in repairs of 11 KV numerical relay 2 o/c + E/F and connected accessories for functional requirement checking of electrical wiring system and testing complete all as specified and directed.
Disconnected of 6.6KV electric supply from existing 2/4 pole structure and maintenance and servicing/ overhauling of existing indoor type, horizontal draw out type VCB, of rupturing capacity 250/350 MVA, current rating of 630-800 Amps by disconnected HT cable termination joints, checking and cleaning all the spare parts of 6.6 KV VCB to avoid any chance of flashing, loose connection sparking, any burning parts and to replace all nuts,bolts and washers, if found any damaged due to flashing,short circuit, moisture descaling(cleaning of joints/busbars),earth fault etc with new one anodiesed of existing size,testing and calibration of earth fault and over load relays complete after re-connection of all dismantled cables and again testing after re-charging the VCB and testing complete with satisfactorily of Engr-in-charge and the necessary spares i e as per original equipment manufactures as per site requirement and materials as under:- (Location BGTC :- BGTC old & Power House No.6 of 6.6 KV sub stn) (Make:- Yamuna & CG)
All as per item No.14 but 11 KV VCB 630 amps complete all as specified and directed:- (Location:- TCP, Nursing Mess and Power House No 2 11 KV Sub Stn)
All as per item No.14 above but VCB 800 amps complete all as specified and directed (Location:- BH,DODA,RCTC, APS , CQB & Power House No.1 11 KV Sub Stn) (Make:- Yamuna & ABB) Note for item No 14 to 16: - (a) New spare parts shall be measured & paid separetly under relevent items as supply only) (b) Cost of sleeves if replaced shall be demed to be included in unit rate only (c) Transportation requirement at site and back cost shall be included in quoted rate only
Supply and fix in repairs connected items of 11 KV VCB monitor display in which circuit breaker 'open' where indication light should be " Green" colour, Breaker 'Close' indication light "Red", breaker 'auto trip' indication light "White" and breaker 'Spring charged' indication light is to be "Blue" and all connected items made serviceable and testing complete all as specified and directed.
M&L for Spray Painting of vaccume circuit breaker 6.6/11 KV following capacity,indoor type with Two coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities and all as per specified and as directed by Engineer-in-charge.
(a) 6.6KV indoor type VCB 630 Amps
(b) 6.6KV indoor type VCB 800 Amps
(c) 11KV indoor type VCB 630 Amps
(d) 11KV indoor type VCB 800 Amps
Testing of dielectric strength of transformer oil of indoor type transformer ,11KV/433 volt,& filteration of transformer oil by passing through filtration machine /plant to remove moisture , impurities and for improving di-electic strength to above 60 KV for 2mm gap and including filling with new transformer oil for toping up & testing after filtration complete as specified. (Location:- TCP,BH,DODA,RCTC, APS & CQB ,BGTC OLD power house & BGTC PowerHouse No.6 11 KV Sub Stn) Note (a) : Transformer oil will be measured & paid separately (b) Contractor carry out the filtration at site by on line machine filtration shall cost quoted in unit rate only
Supply & toping up /replacement of new transformer oil as per IS335 with 50KV di-electric strength complete all as specified. (Make: Power /Asian /Savita/Electric as approved)
Supply & fixing in repair of breather with 1450 Grams celica gel of indoor type transformers of cap 500KVA/400 KVA/315 KVA/250 KVA/200 KVA/160 KVA/100 KVA and 63 KVA, all as specified & all as directed by Engineer - in charge.
Repair and maintenance and servicing and overhauling of step down transformers and disconnecting of LT and HT cable carefully from Transformer and opening top cover by removing nuts, bolts and washers and all mounting accessories and conservator tanks,draining out transformer oil, and including of cleaning of oil tank with replacement of all gaskets,oil seals,servicing of tap chaging gears by cleaning and polishing tapping contact points, and dismantling of 4Nos LT bushing and 3Nos of HT bushing with studs and including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding and cleaning/heating of slica gel in breather and replacing with new silica gel after to make up the reduced quantity and etc and new transformer oil if required for topping up and attending leakages problem and including re assembling and testing with HT megger at the presence of engineer-in- charge upto satishfatory level complete all as specified and directed. Note :- (a) Cost of sleeves if replaced shall be deemed to be included in unit rate only (b) Any transportation requirement at site and back cost shall be included in quoted rate only (c) New transformer oil and spare parts will be measured and paid separatley excluding oil seal
(i) Transformer 63 KVA ,11KV/433Volt
(ii) Transformer 100 KVA ,11KV/433Volt
(iii) Transformer 160 KVA ,11KV/433Volt (Location- PH No-2)
(iv) Transformer 200KVA ,11KV/433Volt
(v) Transformer 250KVA ,11KV/433Volt
(vi) Transformer 315KVA ,11KV/433Volt
(vii) Transformer 400VA ,11KV/433Volt(Location- BH,Make:- Auto Electric Gear)
(viii) Transformer 500KVA ,11KV/433Volt(Location- SUPPLY DEPOT & BGTC)
M&L for Burnt out Studs and Busshing with nuts of any material by providing new copper alloy stud with nut,washers and bushing on HT Side and all as directed for following capacity :
(i) Transformer 63 KVA ,11KV/433Volt (Location- Sainik Cinema Hall ,Make:- Bhart Electric )
(ii) Transformer 100KVA ,11KV/433Volt (Location-TCP& Nursing Mess,Make:- Auto Electric Gear)
(iii) Transformer 200KVA ,11KV/433Volt (Location- DODA & APS,Make:- Auto Electric Gear)
(iv) Transformer 315KVA ,11KV/433Volt (Location- DODA,P/H NO.1 & CQB,Make:- Auto Electric Gear)
(v) Transformer 400VA ,11KV/433Volt(Location- BH & RCTCMake:- Auto Electric Gear)
All as per item No 23 but 6.6 KV Transformers complete all as specified and directed
(i) Transformer 100KVA ,6.6KV/433Volt (Location-BGTC old power House,Make:- Voltamp)
(ii) Transformer 500 KVA ,6.6KV/433Volt (Location-Power House No.6,Make:- Voltamp)
Supply & fix in repair of thermo meter(oil temperature gauge) for indoor type transformer installed at varius Sub stations all as specified & all as directed by Engineer -in -charge for following capacity:-
(i) Transformer 63 KVA ,11KV/433Volt (Location- Sainik Cinema Hall ,Make:- Bhart Electric )
(ii) Transformer 100KVA ,11KV/433Volt (Location-TCP& Nursing Mess,Make:- Auto Electric Gear)
(iii) Transformer 200KVA ,11KV/433Volt (Location- DODA & APS,Make:- Auto Electric Gear)
(iv) Transformer 315KVA ,11KV/433Volt (Location- DODA,P/H No.1 & CQB,Make:- Auto Electric Gear/ Voltamp)
(v) Transformer 400VA ,11KV/433Volt(Location- BH & RCTCMake:- Auto Electric Gear)
Supply & fix in repair of thermometer(oil temperature gauge) for indoor type transformer installed at varius Sub stations all as specified & all as directed by Engineer -in -charge for following capacity:-
(i) Transformer 100KVA ,6.6KV/433Volt (Location-BGTC old power House,Make:- Voltamp)
(ii) Transformer 500 KVA ,6.6KV/433Volt (Location-Power House No.6,Make:- Voltamp)
Disconnected all electrical connections and earth strip at existing Servo Voltage Stabilizer of Capacity 250 KVA all connected accessories/cables and shifting and transportation safely by hydra/ lifting vehicle and including providing suitable carrying vehicle from existing power house to MES yard and once again shifted from MES Yard to required power houses and making all electrical connections properly with earth strip etc and re connected with the shifted Servo Voltage Stabiliser after servicing /overhauling of transformer and testing and including providing functional accessories such as nuts, bolts, washers, lugs, sleevs etc and megger testing and complete all as specified and directed
Material and labour for rewiring of Servo Voltage Stabilizer LT coils with copper wire/strips wound LT coil,re-strectching,rewinding the same after providing new necessary insulting packing material, by using the same old strip/wire complete of existing guage alongwith allied materials complete for upto functional requirement of capacity 250 KVA complete all as specified and drected by engineer-in-charge.
Material and labour for rewinding of step down transformer HT coils with copper wire of existing guage alongwith allied materials complete for upto functional requirement of capacity 300 KVA to 400 KVA complete all as specified and drected by enngineer-in-charge.
Material and labour for rewinding of step down transformer LT coils with copper wire of existing guage alongwith allied materials complete for upto functional requirement of capacity 300 KVA to 400 KVA complete all as specified and drected by enngineer-in-charge.
M&L for Spray Painting of Transformer following capacity,indoor type with Two coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities and all as per specified and as directed by Engineer-in-charge of following capacity:-
(i) Transformer 63 KVA ,11KV/433Volt (Location- Sainik Cinema Hall ,Make:- Bhart Electric )
(ii) Transformer 100KVA ,11KV/433Volt (Location-TCP& Nursing Mess, Make:- Auto Electric Gear)
(iii) Transformer 200KVA ,11KV/433Volt (Location- DODA & APS, Make:- Auto Electric Gear)
(iv) Transformer 315KVA ,11KV/433Volt (Location- DODA,P/H No.1 & CQB, Make:- Auto Electric Gear & Voltamp)
(v) Transformer 400VA ,11KV/433Volt(Location- BH & RCTCMake:- Auto Electric Gear)
(vi) Transformer 500 KVA ,11KV/433Volt(Location- MAP SUP DEPOT)
(vii) Transformer 100KVA ,6.6KV/433Volt (Location-BGTC old power House, Make:- Voltamp)
(viii) Transformer 500 KVA ,6.6KV/433Volt (Location-Power House No.6, Make:- Voltamp)
Material and labour for fault finding on 11 KV HT cables in trenches of any size and any length with fault detective(fault finding) machine by thumbing method and injection suitable high voltage proper fault finding equipment and all as manufactures instructions and including necessary excavation,returning filling,removing surplus soil,sand, existing bricks etc where find the cable faulty complete all as directed by Engineer-in-charge.
Disconnected all electrical connections and earth strip at existing transformer all connected accessories/cables and shifting of 11 KV/0.433 Volts up to 100 KVA to 500 KVA capacity transformer and transportation safely by hydra/ lifting vehicle and including providing suitable carrying vehicle from existing power house to MES yard and once again shifted from MES Yard to required power houses and making all electrical connections properly with earth strip etc and re connected with the shifted transformer after servicing /overhauling of transformer and testing and including providing functional accessories such as nuts,bolts,washers, lugs, sleevs etc and megger testing and complete all as specified and directed
Material and labour for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers, PCC (1:3:6) earth pit chamber type C1, RCC cover (1:2:4) type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.
Material and labour for paintng of 4 pole structure of any type/size/length and removing from existing pole painting by using wire brush and using with emary paper and cleaning with chemical agents after cleaning of steel tubular pole and GI brackets and cross arms in two coats of red oxide primer and two coats of silver oil painting upto smooth finishining and painting to satisfactorly by engr-in-charge and painting work carryout at any height and including marking of pole numers as directed and safety eqpts & tools will be own arrangement and complete all as specified and directed. (Note:- Cost of painting material is deemed to be included in quoted rate only).
All as per item No. 36 but 2 pole structure and complete all as specified and directed
Material and labour for tree branches/vegitation cutting around the 2/4 polestructure and HT lines and installations from line conductor to tree distance up to 4 mtrs and cutted wood pieces/vegitation materials disposal upto distance not exc 100 mtr at defence land location where as directed and including providing safety eqpts & cutting tools,ladders etc will be own arrangement by the contractor and complete all as specified and directed. Note:- (1) Safety measures will be fully responsible by tenderer (2) During tree /branches/vegitation cutting any damages on OH lines/installation should be reuniform responsible fully by the tenderer with out any extracost.(3) Approximately distance covered both side for the HT lines/installatons not exc 100 mtr measured as a one Job only
M&L for steel tubular swaged type poles 11 metrs long,pole weight approximately 175 to183 kgs, pole should be in one piece only and smooth finishing,ISI marked complete with all accessories such as cast iron base plate, finial taper plug,bolts, nuts, screws,washers and drilling of holes for continious GI earth wire as specified type 410 SP-53 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface etc. incl. dismantling of old unserviceable pole complete all as specified and directed.
Material and labour for steel tubular pole painting of any type/size/length and removing from existing pole painting by using wire brush and using with emary paper and cleaning with chemical agents after cleaning of steel bubular pole and GI brackets and cross arms in two coats of red oxide primar and two coats of silver oil paint upto smooth finishining to satisfactorly by engr-in-charge and painting work carryout at any height, including safety eqpts & tools will be own arrangement and complete all as specified and directed
Material and labour for PCC pole painting of any type /size/length and removing from existing pole painting by using wire brush and cleaning with with cotton waste after cleaning of PCC pole in two coats water proof cement based paint in two coats and GI brackets and cross arms in two coats of red oxide primar and two coats of silver oil paint upto smooth finishining to satisfactorly by engr-in-charge and painting work carryout at any height, including safety eqpts & tools will be own arrangement and complete all as specified and directed
M&L for cross arms, bracings, supports, clamps and back plates fabricated in structural GI sections including nuts, bolts,washers, welding, bending, fabrication, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide primar, one under coat and one finishing coat of silver paint and including dismantling and removing old unserviceable items complete all as specified and directed
Material and labour for PCC (1:4:8), type D2, (using 40 mm graded stone aggregate) for making good cutting portion, mass concrete, filling of foundations etc including necessary use and waste of form work complete all as specified and directed
Material and labour for PCC (1:3:6), type C2, (using 40 mm graded stone aggregate ) for making good distrubed road surfaces including necessary use and waste of form work complete all as specified and directed
Supply and fix in repair 11 KV out door type Air Break gang operated device of rating 400 Amps, triple pole, vertical type, mechanically operated, mounted on HT insulators and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium grade with operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supply cand testing complete all as specified and directed. (Make :- Atlas/Elpro/ECE/Pactil/Oblum)
Supply and fix in repair 11 KV out door type Air Break gang operated device of rating 200 Amps, triple pole, vertical type,mechanically operated, mounted on HT insulators and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium grade with operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supply cand testing complete all as specified and directed.(Make :- Atlas/Elpro/ECE/Pactil/Oblum)
Supply and fix in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm and testing complete all as specified and directed. (Make: Raychem/M-Seal/Denson)
Supply and fix in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm and testing complete all as specified and directed. (Make: Raychem/M-Seal/Denson)
Supply and fix in repair cable jointing kit for 11KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm and testing complete all as specified and directed. (Make: Raychem/M-Seal/Denson)
Supply and fix in repair cable jointing kit for 11KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm and testing complete all as specified and directed. (Make: Raychem/M-Seal/Denson)
Supply and fix in repair cable jointing kit for 11KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm and testing complete all as specified and directed. (Make: Raychem/M-Seal/Denson)
Supply and fix in repair cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm and testing complete all as specified and directed. (Make: Raychem/M-Seal/Denson)
Supply and fix in repair cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm and testing complete all as specified and directed. (Make: Raychem/M-Seal/Denson)
Supply and fix in repair HT 11 KV out door expulsion type lightning arrestor of transmission class having discharge capacity 65 kilo Amps including mounting accessories complete fixed on cross arms of 4 pole structure and connected with ACSR conductor & earthing connections aand testing complete all as specified and directed.
Supply, laying, testing and commisssioning HT cable, XLPE insulated (Earthed), 11 KV, screened PVC bedded, galvanized steel strip armoured, with stranded aluminium conductor of cross sectional area 95 sqmm,3 core conforming to IS:7098 part-II with latest ammendments up to date including suitable aluminium lugs with proper crimping and laid in trenches/ducts/wall/through pipes etc including taking down old unserviceable cable complete all as specified and directed. Note:- (i) Excavation,Earth work,sand cushioning,cable covers and cable protection pipes shall be measured and paid separately.) (ii) The cable shall be in one length unless otherwise directed by GE.
Supply and laying reinforced precast concrete cable cover class HT, Type 1, flat, size 300mm x 180 mm x 40 mm for protection under ground HT cable complete all as specified and directed
Material & labour for GI pipe 100mm "light grade" laid in trenches floors/on pole/road for cable protection with all fittings etc including taking down old unserviceable pipe complete all as specified and directed .
Material & labour for GI pipe 80 mm "light grade" laid in trenches floors/on pole/road for cable protection with all fittings etc including taking down old unserviceable pipe complete all as specified and directed .
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft /loose soil complete all as specified and directed.
Returning, filling in, soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
Supply and fix drop out fuse unit expulsion type for air break gange operated switch single pole mounted on and including insulators for 11KV working pressure fixed to and including MS channel with nut,bolts and washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 50Amps and testing complete all as specified and directed. (Make:- Jaipuriya Brothers /RAMCO/ Atlas /Elpro /ECE /Pactil /Oblum)
M&L for cleaning the vegitation grass, bushes etc inside and out side the installation perimeter incl. necessary gardening works and surface excavation in all repect to maintain the installation premises in inspection mode and also cleaning of installation, panel room, verandah, labour rest room, toilets etc and allied rooms complete all as specified and directed. Note:- (a) Neccessary tools like cutting, digging, cleaning cane brooms with bamboo handle etc for gardening purpose required. (b) The cost of all items mentioned are included in item rate, no extra payment will be paid separately.
M&L for hardcore of gauge n.exc. 40mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface etc complete all as specified and directed.
M&L for calibration and testing of protection relays of any make or type fitted on 11 KV RMU's/CSS as per IS and code of practice to ensure NO ERROR including setting for earth fault, over current, phase over current with trip time delay in accordance to feeder load and other parameters of site, settings to ensure that fault shall not travel to nearest source feeder including minor repair, replacement of wiring etc, if required all as directed by Engr-in-Charge. Note :- (a) The setting shall be carried out by only qualified engineers. (b) Caliberation shall be carried out as per load and site conditions to avoid any fault.
S & F Relay of RMU upto 630Amps, complete all as specified and as directed.
S & F HT bushing of RMU upto 630 Amps, complete all as specified and as directed.
Papai Enterprises
JADAV CONSTRUCTION
Ultimate Solution Company
SOMIK DAS
SOMA BUILDERS
MPM ELECTRIC
ChakrabortyTraders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .