Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC LANE NO 11 HOUSE NO 4 INDRAPRASTHA COLONY UPPER NATHANPUR RING ROAD DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹32.3 L | L1 | Accepted-AOC AOC accepted. |
| 2 | L2₹33.7 L+₹1.4 L (4.18%)Rejected-AOC | ₹33.7 L+₹1.4 L (4.18%) | L2 | Rejected-AOC AOC rejected. |
| 3 | L3₹35.1 L+₹2.8 L (8.66%)Rejected-AOC | ₹35.1 L+₹2.8 L (8.66%) | L3 | Rejected-AOC AOC rejected. |
| 4 | L4₹36.3 L+₹4.0 L (12.4%)Rejected-AOC | ₹36.3 L+₹4.0 L (12.4%) | L4 | Rejected-AOC AOC rejected. |
| 5 | L5₹37.1 L+₹4.7 L (14.6%)Rejected-AOC H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | ₹37.1 L+₹4.7 L (14.6%) | L5 | Rejected-AOC AOC rejected. |
Tender Value
Refer Docs
EMD Value
₹95,400
Closing Date
28 Jul 2021, 6:00 pmClosed
GE DEHRADUN
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair to leakage/ seepage, joinery, flooring, ceiling, plastering, approach path, drain and internal electrification of Md Accn at Birpur under GE Dehradun
2021_MES_455791_1
8310/A/E8
Open Tender
Civil Works
Item Rate
120 days
GE DEHRADUN
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹95,400
Yes
27 Sept 2021
30 Jun 2021
30 Jul 2021
30 Jun 2021
28 Jul 2021
14 Jul 2021
Amount
Taking down chowkhats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed.
All as per Srl Item No1 here-in-before, but exceeding 1.5 Sqm and n.exc 4 Sqm(without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each complete all as specified and directed.
Taking down shutters of any description n.exc 1 Sqm each complete all as specified and directed.
M/L 30mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified in SSR Part I.
M/L 30mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated without sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified in SSR Part I.
S&F 30mm Flush shutters, factory made solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified in SSR Part I.
M/L 35mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(a) complete all as specified in SSR Part I.
M&L for 2nd Class hardwood Plain, solid, straight Chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together withglue pinned at joints, supplied & fixed complete all as specified and directed.
S&F Factory Made with particle board core Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with but 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified in SSR Part I complete all as specified and directed.
S&F solid PVC Door Frame prelam of size 95mm x 50mm made out of 5mm PVC sheet reinforced with MS tube match with moulded door shutter supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F 18/19mm prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work and wooden leaping alround the shutter complete all as specified and directed.
Taking down and re-fixing the existing shutter in same opening after & including necessary easing/repair etc. 1 sqm but n. exc. 2 Sqm each complete all as specified and directed.
Taking down and re-fixing the existing shutter in same opening after & including necessary easing/repair etc. n exc 1 sqm each complete all as specified and directed.
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete with glazing bars dovetailed or welded with one shop coat of primer complete all as specified and directed.
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete without glazing bars, as fly proof shutters with one shop coat of primer complete all as specified and directed.
S&F factory made steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
Taking down existing projected type hinges from the steel window carefully with disturbing frame and S&F and fix 50 mm long mild steel box type hinge weld to steel frame and shutter with welding and making good including touch with paint and with existing surfaces complete all as specified and directed.
M&L in repair plain fillets 2nd class Hard wood exc 13 & n exc 25 Sqcm Square or rectangular in section, wrought secured with nails or barbs complete all as specified and directed.
S & F Framed work such as grills, gratings , Iron Chowkhats etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming toFe 290. Gde-E-165 complete all as specified and directed.
S&F butt hinges, mild steel medium weight 100 mm size with nut & bolt complete all as specified and directed.
S&F butt hinges, mild steel medium weight 75 mm long size complete all as specified and directed.
S&F 100 mm size stainless steel butt hinges and fixed with stainless steel screws, complete all as specified and directed by Engr-in-Charge.
S&F 200 mm long, stainless steel barrel tower bolts of extruded section 10mm dia shoot complete all as specified and directed by Engr-in-charge.
S&F 150 mm long, stainless steel barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm size stainless steel handles,cast D type,anodised all as directed complete all as specified and directed by Engr-in-Charge.
S&F 125mm size stainless steel handles,cast D type,anodised all as directed complete all as specified and directed by Engr-in-Charge.
S&F 300mm long MS Helical door spring welded to steel frame or fixed to wooden door frame with screws including roller and roller plate etc complete all as specified and directed.
S&F in repair 300mm long MS Helical door spring to steel chowkhat with same as but fixed to wooden door frame including roller and roller plate etc complete of approved quality.
S&F Hasp and staple 100mm safety type, stainless steel with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F floor door stopper of stainless steel double legged and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and directed.
S & F Continuous (Piano) hinges, mild steel, bright finished or electro galvanized, width of flaps (When open) 30 mm complete all as specified and directed.
S&F magnet catcher for cub board with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F stainless steel sliding door bolts, hasp and staple type with bright bolt not less than 16mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm long complete all as specified and directed.
S&F in repair peg set of five stainless steel fixed on CP steel plate including fixing screw as per approved sample complete all as specified and directed.
M&L sheet glass ordinary quality 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc. .5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed.
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing fixing new ones complete all as specified and directed.
Hacking out old broken glass ( any thickness , size, quality, or description) from wooden frame glazed with putty or fixed with beads all as specified and directed
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as directed by Engineer- in -Charge.
S&F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as directed by Engineer- in -Charge.
M&L for second class hardwood beads, straight nexc 9 sqcm in section for fixing galvanised MS wire cloth, including mitres etc. complete all as directed by Engineer-in-charge.
M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair 25 mm dia MS drapery rod with wooden finish, decorative, including brackets, decorative finished at both ends complete all as speccified and directed as per approved sample.
Demolition of cement concrete ground floor and paving nexc 15cm thick (below or above ground level) and dispose with in the MD land 1.5km as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement and demolition of existing old cement concrete of plinth protection in ground floor and paving below or above ground level complete all as specified and directed.
M&L for coloured Non Skid Ceramic joint free tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed.
M&L for coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 350mm x 250mm x 7mm/ 450x 350 x 7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and ditected.
M&L for coloured Non Skid Ceramic joint free tiles 7 to 8mm thick (square/rectangular) as in skirting cut from tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slury and pointed in white or coloured cement to match including screed bed 10mm thick in cm 1:4 complete all as specified and directed.
Demolition of Stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons complete all as specified and directed.
M&L for Udaipur green stone pre polished mirror for flooring/self slabs 12-15mm thick over 15 mm thick cement screed bed in CM 1:6 base laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rounding of edges of stone complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works and dispose of rubbish with in MD land all as directed by Engr-in-Charge.
M&L for reinforced cement concrete (nominal mix) 1:2 :4 type B1 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like. Note :- Reinforcement & formwork shall be measured and paid for separately complete all as specified and directed.
S&F TMT MS bar 8 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc. including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed.
M&L 10 mm thick ceiling plaster in CM (1:4) on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L rendering 15mm thick in cement mortar 1:4 mixed with water proofing compound of cement finished fair faces of brick/concrete surfaces, chajja/ facia even and fair without using extra cement complete all as specified and directed.
M & L rendering 15mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and directed.
Supply only integral waterproofing compound complete all as specified and ditected.
M&L applying silicon based water proofing chemical by spray on walls complete all as specified & directed by Engr-in-charge
M&L for three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed.
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over primer coat of approved tint complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over primer coat of approved shade on walls all as specified & directed by Engineer-in-Charge.
Dismantling asbestos cement sheet (Corrugated, semi corrugated etc ) in roof covering complete all as specified and directed.
M&L for 6 mm thick asbestos cement corrugated or semi corrugated sheets in roof fixed with 'L' type or J type or cranked hook bolts complete all as specified and directed.
S&F 0.63mm plain galvanised mild steel sheeting in ridges , hips, valley gutters , drip and straight flashings with frade of zink coating 275 incl dismantling of old plain or corrugated steel sheet complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs /blankets any thickness incl cover fillets complete all as specified and directed.
Providing & fixing tiled false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 3mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engineer-in-Charge.
S&F roof trusses (framed), trussed, purlins crane gantries, rails & fastenings & heavy brackets framing Fe-410W Gde E-250 quality A (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 15 mm bore GI tubing complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 20 mm bore GI tubing complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling as directed, for 15mm bore GI tubing complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling as directed, for 20mm bore GI tubing complete all as specified and directed.
M&L cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth complete all as specified and directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing complete all as specified and directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing complete all as specified and directed.
S & F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend of suitable size complete all as specified and directed.
S&F in repairs PVC connection 15mm size with PTMT nuts, of 450 mm long complete all as specified and directed.
Dismantling water tank of exc 500 ltr and not exc 1000 ltr Capacity complete all as specified and directed.
S&F rotational moulded polyethylene 500 Ltrs Capacity water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float three layer external white and fly nut complete screwed down for iron pipe of 20 mm dia complete all as specified and directed.
S&F in repair vitreous china wash hand basin including brackets, white size 550 x 400 mm incl cutting cutting for and pinning in ends of brackets. Including Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed.
S&F CP brass fancy type Pillar Tap High Neck complete all as specified and directed by Engr-in Charge. Make :- Jaquar product code : 5357N or equivalent in Hindware/ Parryware.
S&F in repairs vitreous china water closet (squatt pan) orrisa pattern 580x440 mm size pan white with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to 'flushing cistern/pipe complete all as specified and directed including 100mm dia CI 'P' trap of 60cm long complete all as specified and directed.
S&F in repair ball valve high pressure of PTMT with epoxy coated alum rod & high density plastic ball screwed for 20mm bore iron pipe and fixed ( minimum weight 20mm -210 gms) complete all as specified and directed.
S&F in repair epoxy coated alum rod only for PTMT ball valve with screwed both side for 20mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair heavy duty PVC ball in white colour for PTMT ball valve with screwed both side for 20mm bore iron pipe and fixed complete all as specified and directed.
S&F in repairs vitreous china water closet Padestal pattern (white) excluding fixing bolts, flushing cistern and flush pipe and including EWC Sheet cover complete all as specified and directed.
S&F in repair looking mirror of size 450mmx600mm x 5.5 mm thick or higher size mounted on decorative type PVC frame fixed to PVC plug with CP brackets screw fixed, complete all as specified .
S&F in repair CP brass bib tap fancy type 15mm bore screwed for iron pipe or for brass ferrule. Make-Pearl/Essco/Jaquar
S&F in repair 15mm bore Bib taps long body cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. Make : - JAGUAR CAT Part No ALI-85037/Hindware CAT Part No F-370004/Prayag CAT Part No S9906
S&F in repair 15mm bore bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/ 20mm-125gms) complete all as specified and directed.
S&F in repairs CP brass Angle Valve 15mm dia. Make - Jaquar(ESSCO) Cat Part No. ES 526 or or equivalent in Hindware/ Parryware.
S&F in repairs 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified.
S&F in repair CP brass shower rose with arm 15mm dia and shower 100mm dia complete all as specified and directed.
S&F in repair PVC Shelves of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105 gms) complete all as specified and directed.
S & F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S&F in repair heavy duty thread type PVC water tank cover with fixing frame fixed on PVC tank with 4 Nos of screws complete all as specified and directed.
Taking down AC/Salt glazed ware pipes and fittings upto 110mm complete all as specified and directed.
S&F 100mm dia centrifugally cast (spun) iron pipe in any length with or with ears, with cement joints laid in trenches or in floors as per IS-3989-1984 complete all as specified and directed.
S&F 100mm dia centrifugally cast (spun) iron pipe in any length with or with ears, fixed to wall as per IS-3989-1984 complete all as specified and directed.
S&F 75mm dia centrifugally cast (spun) iron pipe soil and waste pipe in any length with or with ears, with cement joints laid in floors as per IS-3989-1984 complete all as specified and directed.
S&F 75mm dia centrifugally cast (spun) iron pipe soil and waste pipe in any length with or with ears, fixed to wall as per IS-3989-1984 complete all as specified and directed.
S&F in repair centrifugally cast (spun) iron bends with cement joint any radius for 100pipe.mm dia with duck 's foot or heel rest complete all as specified and directed.
S&F in repair centrifugally cast (spun) iron bends with cement joint any radius for 75pipe.mm dia with duck 's foot or heel rest complete all as specified and directed.
S&F in repair centrifugally cast (spun) iron pipe branch peices, single(equal or unequal) ordinary or inverted (spigot or socket type), or with parrallel branches fitted with oval access doors of 100mm bore dia complete , ISI Marked, fixed in repairs all as specified & directed.
S&F in repair 75mm centrifugally cast (spun) iron branch piece single equal spigot or socket type fitted with oval access doors complete all as specified and directed.
S&F in repair centrifugally cast (spun) iron bend (any radius) of 100mm bore with oval access door complete all as specified and directed.
S&F in repair centrifugally cast (spun) iron bend (any radius) of 75mm bore with oval access door complete all as specified and directed.
S&F in repair 100 mm dia centrifugally cast (spun) iron cowls complete all as specified and directed.
S&F in repair 75mm dia centrifugally cast (spun) iron fioor trap with grating including jointing to waste pipe fixed in cement concrete type B 1(1:2:4) complete all as specified and directed.
S&F in repairs for 75mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed.
S&F in repairs for 100mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed.
S&F in repair 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F in repair 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F in repair Grating round 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
S&F in repair 32mm bore heavy duty waste pipe with PVC coupler for WHB all as directed by Engr-in-Charge.
S&F in repair 40mm bore heavy duty waste pipe for kitchen sink complete all as specified and directed by Engr-in-Charge.
S&F in repair stainless steel sink coupling with waste pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair CP steel Grating round with steel frame with hinge 100mm dia all as sample approved by Engr-in-charge.
Cutting around the pipe 75/100mm bore waste pipe/soil pipe including taking out plant roots up to any depth in brick masonary and rejointing in pipe joint in CM 1:2 and making good to existing surface all as directed by Engr-in-charge. (After the jointing pipe one week to be open for checking of leaking including scaffolding)
Removing / cutting trees vegetation, digging out roots from concrete or brick wall, filling holes on building (Block of 4 qtrs) wall / roof / chajja etc applying and making good with epoxy mortar (Asian/Berger) and applying surface treatment to match with existing specifications complete all as specified and directed.
M&L taking down existing plaster from the roof including existing treatment and M&L 15mm thick cement plaster in cement motar 1:3 on concrete surface finished even and smooth with using extra cement with water proofing compound (water proofing compound will be paid separately) all as directed by Engr-in-charge.
M&L applying evenly a tack coat industrial bitumen 85/25 at the rate of 1.20 Kg per Sqm including cleaning of surface on roof all as directed by Engr-in-charge.
M&L one coat of aluminium bitumen paint @ 0.30 litres/Kg on the roof all as directed by Engr-in-Charge.
M&L for rendering 10 mm thick on fair faces of roof surface and sunken portion in cm 1:3 finished even and smooth (with out using extra cement) using water proofing admixture incl taking down old plaster complete all as specified and directed.
M&L for PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation filling and mass concrete (sunken floors) complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for complete all as specified and as directed.
M&L for preparation of old decorated surfaces of walls (plastered) by brooming down with steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and finally clean with sand paper all as directed by Engr-in-Charge.
M&L for complete removal of existing treatment from wall upto plaster surface by washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper all as directed by Engr-in-charge.
M&L preparation of old decorated surfaces of ceiling (Plastered) by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.
M&L one coat of white wash on already prepared surfaces of wall using DDL complete all as specified and directed.
M&L one coat of white wash on already prepared surfaces of ceiling using DDL complete all as specified and directed.
M&L one coat of oil bound distemper in any tint on already prepared surfaces of walls complete all as specified and directed by Engr-in-Charge
M&L two coat oil bound distemper any tint on already prepared surfaces of walls complete all as specified and directed by Engr-in-Charge.
M&L one coat of cement base paint on external already prepared surfaces of wall surfaces complete all as specified and directed by Egnr-in-Charge.
M&L two coat of cement base paint over primer coat on external already prepared wall surfaces complete all as specified and directed Engr-in-Charge.
M&L for preparation of wall and applying wall putty 2 to 3 mm thick interior grade to make the surface smooth as specified and directed by Engr-in-Charge.
M&L for preparation of wall and applying exterior grade wall care putty 2 to 3mm thick to make the surface smooth as specified and directed by Engr-in-Charge.
M&L one coat of whether proof exterior emulsion paint on brick/concrete on already prepared wall surfaces complete all as specified and directed by Engr-in-Charge
M&L two coat of whether proof exterior emulsion paint over primer coat on brick/concrete wall surfaces plastered surface of walls incl preparation of surfaces all as specified and directed by Engr-in-Charge.
Preparation of old AC sheets surfaces by brooming down with steel wires brushing and washing with water and applying one coat of Apex paint, complete all as specified in SSR part Iand directed by Engr-in-Charge.
M&L for preparation of old painted steel surfaces over 10 cm width/girth and applying one coat of synthetic enamel paint all as specified in SSR Part I and directed by En gr-in-Charge.
M&L for preparation of old painted surfacesof wood over 10 cm width/girth and applying one coat of synthetic enamel paint all as specified in SSR Part I and directed by Engr-in-charge.
Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm highWriting bldg No all as specified and directed by Engr-in-Charge.
Cleaning of existing water storage tank with vaccume cleaner machine exc 250 to 1000 ltrs capacity with liquid bleach and dry with and apply on coat of anti bacterial spray and refil including cleaning float with five steps as per PS Clause. Date of cleaning to and CA No to be painted with synthetic enamel paint on water storage tank with stencil in black/white paint all as directed by Engr-in-charge. Note : Any damage to float valve/sintex cover/GI pipe will be responsible and change/repair will be the contractors responsibility without any charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and directed.
M&L for 65 mm thick vibromatic reinforced precast cement concrete 1:1:2 (using 20mm graded stone aggregate) with 2mm thick mild steel CR sheet around painted with 2 coats of bituminous paint , as in man hole cover slabs finish fair even and smooth without using extra cement ( Top surface will be chequred finish) including necessary form work, 100 mm long handle of 12mm dia round bar counter sunk by 25mm welded to reinforcement complete all as specified and directed by Engr-in-charge (Note : CA No and date will be engraved on covers. Reinforcement shall be measured and paid saperately. Curing will carried out with ponding method)
S&F TMT MS bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia as specified and directed.
Demolition and breaking up drain pipes (SGSW, AC or RCC) 150mm bore set in cement mortar including PCC bedding / haunching complete all as specified and directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre depth for foundation, manhole etc not exc 10 Sqm on plan and not exc 1.5 metre in depth including getting out in soft/loose soil complete all as specified and directed by Engr-in-charge
Returning, filling in including spreading, leveling watering and well ramming in layers not exceeding 25 centimetre in soft/loose soil complete all as specified and directed by Engr-in-charge
Removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engr-in-charge
M&L for Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) bed for drain Pipes of bore 150mm including Packing under and Haunching against the Sides of Pipes after they are laid in Foul Condition and Testing, complete all as specified and as directed.
S&F for Reinforced cement concrete drain Pipes 150 mm dia NP-2 , laid in trenches in foul condition, Jointed with collars in cement mortar and tested, complete all as specified and as directed.
Cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete al as specified and directed.
M&L for salt glazed stone ware gully traps square or rounded mouthed type ‘P’ of size 150x150mm embedded in PCC with necessary brick work . plastering etc complete and connecting to pipe all as directed by Engineer-in-charge.
M&L Cleaning of existing seawage pipe lines 100mm/150/200mm internal dia at any depth inciuding manholes by removing the manhole covers of any type / size and cleaning by means of hydraulic jet pressure machine manually as requierd at site from manholes and well flushing with water after cleaning including getting out sudge if any and liquid materals from connecting manholes deposited in sewar line removing the solids and sludge to any distance and reinstating the manhole cover to its oiginal postion (cost of removal of sludge/liquid material from sewage lines and manholes in same line is incl. in rate of this item and rate quoted also includes for keeping particular sewage line which is undertaken once for cleaning, functional for full contract period) complete all as specified and directed.
Removing the manholes covers and de-sluding /de-watering of septic tank and soakage well of any size and depth by mechanical pumping by plugging inlet as requried,and making the septic tank and soak well fully functional to the entire satisfaction of Engr -In- Charge including carrying the effluent out of MD land using 5000 ltr capacity sewage tanker and re-instating the manholes cover to its original postion complete all as spd and directed by Engr-In Charge
M&L cleaning the blockage of bathroom/ kitchen by cleaning the Nahani traps/gully traps of all the mud/sludge and getting out, washing thoroughly grating of tarp, CI waste pipes by opening the clearang eyes and deposting the sludge in a pit of suitable size at a distance not exceeding 50 meters form the gully trap and and covering the same with the soil obtained from excavation of pit including all excavations and earthwork complete all as spd and directede by Engr -in- Charge. (the quoted rate includes for keeping particular bathroom/kitchen undertaken once for cleaning functional for full contract period)
M&L Cleaning of blockage of WC indian or European type by removing of all the mud/ sludge and getting out including cleaning of SGSW or CI pipe upto First manhole and deposting the sludge in a pit of suitable size at a distance n' exc 50 meters from the wc and covering the same with the soil obtained from excavation of pit including all excavations and earth work complete all as spd and directed by Enge-In -Charge. (The quoted rate includes for keeping particular WC under taken once for cleaning, functional for full contract period)
Cleaning of Man hole any depth any size taking out accumulated, soil , sludge any material incl both ends and removal to MD lands and manhole cover refixing all as directed by Engr-in-charge.
Notes. For cleaning of sewage system:- (a) Contractor's representative shall attend office of Engr-in-Charge on all working days at 0900 hrs to collect the complaints pertaining to blockage of traps, cleaning of sewage lines, manholes, septic tank and soak wells . In case contractor's representative fails to report Rs 450/- per day will be deducted from the contractor payment for the absent period. (b) complaint slips shall be deposited to the JE concerned after completion of job duly singed by the users. payment shall be made on the basis of complaint slips and site verification by JE/ Engr-in-Charge. (c) Contractor shall provide printed complaint register/ slip as per format given by Engr-in-Charge before commencement of work. (d) The work in foul conditions such as cleaning of soakwell, septic tanks, manholes etc shall be carried out with mechanical means where work with mechanical means is not practicle and work shall be executed manually with the permission of Engr-in-Charge.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed by Eng-in-charge.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following. Make of PVC Wire: Havells/KEI/Finolex/L&T. Note: The wiring to be done as per IE rule and maintain colour code accordingly.
(a) One light point point /bell buzzer point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
(e) One light point controlled by two way switch
All as per item No 169 (d) above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 1.5 Sq mm.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in existing PVC / Steel, concealed and existing MS boxes, mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following Make of PVC Wire: Havells/KEI/Finolex/L&T. Note: The wiring to be done as per IE rule and maintain colour code accordingly
One light point point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two way switch
All as per item No 171 (d) above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 1.5 Sq mm.
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified.
S&F Bell switch paino flush button type 5 Amp complete all as specified.
S&F ding dong bell AC 230 V single pole complete all as specified and directed .
S&F switch paino flush button type 5 Amp SP 2 way complete 250 V AC all as specified and directed.
S&F step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Ampds 400 watts.
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC.
S&F lamp holder,pvc/polycarbonate type with back platesuitable for batten fittings including 9w LED bulb complete all as specified & directed.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm (nominal area) drawing in and including 20 mm dia or higher medium duty PVC concealed conduit/flexible conduit where reqd and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 6 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium duty PVC concealed conduit/flexible conduit where reqd and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4 Sqmm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
S&F in replacement sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed.
S&F in replacement sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed.
S&F MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed.
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed.
S&F MCCB 415 Volt 16 KA 4 pole 63 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed.
S&F in replacement of U/S Tamper Proof electronic single phase whole current energy meter (LCD Display) 10 Amp to 60 Amp, 240 volt class 1.03 and class 2.05 AC supply including cable connection, proper sealing with lead. The meter shall comply with the latest version of IS-13779 with atleast 2 anti tamper LED indication of line load reversal and earth loading indication including electrical connection with existing system and sealing properly including push fit type pvc box complete. The meter shall work satisfactory with guarantee accuracy as per limit of IS-13779. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. (Note: Old U/S Meter shall be deposited to E/M store yard). Make:- L&T/ Legrand/Secure/BHEL.
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten)CRYSTAL1213T8DSTL20WLED865SGLASS(TUBE DOUBLE SIDE)
Supply, Fixing and testing LED down lighter recessed mounted 2x2 feet36W ultra modern designed LED luminaire which provide soft light and glair free symmetrical illumination suitable for grid ceiling and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on as per Havells Cat Part no: ENDURASLIMPROPLUS2x2PLR28/36WLED 840MOD or equivelent make of PHILIPs/ CROMPTONall as directed by Engineer-in-Charge.
S&F LED light fitting 1x10 w bulk head fitting complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size Make:WIPRO CAT PART NO-LW07-141-XXX-57XXor equivelent , HAVELLS/CROMPTON
S&F in replacement LED light fitting decorative wall mounting SS brush finish fixture with frosted glass suitable for upto 1x40 watt mini glass lamp with and including one no 12 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable sizeAs per Havells Cat Part NO LHFOAJE1TN1IO60 or equivelent of Bajaj/ Philips.
S&F mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size . Make Havells Cat No Edgelite or equilent in Philips/Wipro
Supply only LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed.
S&F Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 40/45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed. Make:- Crompton model No. LSTP-45-CDL/Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand syska SSK-ST-40W including taking out old unserviceable street light.
M&L for service cable 6 sq mm twin core Weather proof aluminium multistranded conductor cable PVC sheathed PVC insulated round suspended with No.8 SWG GI wire and reel insulators at distance of 01 mtr duly connected with earthing and clamp etc from Pole to pole completeMake of PVC Cable.
All as per Item No 198 but 10x2 sq mm Cable.
Supply only LED tube rod 18/20 Watts single or double sided connections polycarbonate complete incl making connection alteration in existing tube light fitting complete.
S&F in replacement of ceiling fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan comlete all as specified and directed Make Havells/ Crompton/ Orient/ GEC.( Note: Old unserviceable ceiling fan will be deposited in E/M store yard).
S&F in replacement of 3 core PVC insulated copper cable of size 40/0.0076 multi standard in repairs complete all as specified and directed by Engineer-in-Charge.
S&F copper flexible wire twin core 23/0076 for connection of ceiling fan etc complete all as specified and directed.
Disconnecting electric connection and taking downhof ceiling fan / Exhaust fan removing capacitor,split pins of any sweep ceiling fan / Exhaust fans complete carefully for overhauling checking of bearings/bush, cleaning the fan blades with cleaning solution, replacing the unserviceable bearing, bush, capacitor , safety split pin and nuts, bolts, washer etc duly threaded of down rods (bush, bearing, capacitor, down rod, hanging clamps, will be paid under relevant item of the Sch 'A') reassembling the ceiling fan complete after greasing/servicing, oiling testing the same making the fan in serviceable condition ana refixing/ hanging the same complete all as specified and directed by Engineer-in-Charge . Note 1: Cost of Split pins, nut bolts and threading of down rod pipe rates are included in quoted rate
Supply only standard ball bearing of ceiling fans of 1200/1400 mm sweep to suitable for different makes of fans of approved quality including necessary greasing. Make :- NORE/NBC/SKF
Supply only bush gun metal suitable for ceiling fans 1200/1400 mm sweep/exhaust fan 300 to 400 mm sweep, cabin fan of any make any size complete all as directed at site.
Supply only fan capacitor 2.5/3.15 mfd make universal / Asian/Epcos .complete all as specified and directed
Supply only fan capacitor 4 mfd complete all as specified and directed make universal / Asian/Epcos
S&F in replacement air ventilation fan matalic body 300mm, 900 RPM, single phase, 230V AC including necessary, M&L for making hole fixing arrangement on wall with frame holdfastner, bolt, washer etc including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector all a directed by Engineer-in-charge. Make:- Havells cat part No. Ventil Air DXWHT, CG cat No. BRISKAIR or equivalent Orient.Note: old unserviveable fan shall be deposite in E/M yard.
S&F in relacement LED decorative post top lantern for Garden light 40 watt IP 65 protection resistance to impact and corrosion glare, free and better uniformity milky version as per CG cat part No LPTO40CDL/ Bajaj model No. BGCTW4LEDWW including taking down old unserviceable post of lantern.
Supply, Fixing & Connecting wall mounted fan oscillating type 400mm sweep single phase 230 Volt complete all as specified and directed.Make :- Havells/ Crompton/ Usha( Note: Old unserviceable Exhaust fan will be deposited in E/M store yard. )
Dismantling electric and water connection of the 25/50 ltr's geyser, taking down from its original position on ground, dismantling geyser complete such as removing tank from its outer body, removing apparatus plate from the tank, descaling the geyser inner tank and apparatus plate complete, testing its thermostat, heating element, and tank from leakage, reassembling the geyser, replacement of unserviceable parts such as heating element, rubber gasket & testing the geyser and installation of the geyser into its original position and connecting all electric and water supply connection complete and testing on completion all as directed by Engineer-in-Charge. (Heating element & Aparatus if require to be replaced shall be measured and paid separately) (Nut, bolts and hold fastners if require to be replaced shall be deemed to be included in the quoted rates of this item). Note: All repair shall be carried out on complaint basis and measurement will be made only once through out the contract period irrespective number of repair carried out in same Geyser. All repairs shall be carried out on complaint basis contractor shall be delay to the maintenance and collect complaint slip from concerned JE daily upto 11.00 Hrs
Supply only heating element any type/size as per site requirement of capacity 2 KW ISI Marked. Make:-Theta/Newton/Dasmesh/Bajaj
Supply only thermostat for geyser long type 11" in length as per site requirement temp setting on 60 degree centigrade ISI Marked, long type complete all as specified and directed. Make: Dashmesh/Indofors/Donfoss/Bajaj
Supply only in replacement of water supply PVC flexible connection Nylon braided with suitable threaded check nut with washer complete (Each set of two) suitable for hot/ cold water 15mm dia alongwith threaded Brass nuts and washers 45 cm long complete all as specified and directed. Make:- POLO/Havells/Prayag
Supply only syphon assembly for geyser any type of hole (6/7/9) all complete as per existing make & size as per site requirement all complete all as directed by Engr-in-Charge. Make:- Dashmesh/Theta/Newton/Bajaj.
Supply only pressure release valve as per existing make and size geyser spring loaded 15 mm dia complete all as specified and directed.
Supply only rubber Gasket as per existing make/size site requirement suitable for 25/50 Ltr capacity geyser complete all as specified and directed.
S&F in replacement Sheet metal enclosure SPN with a two pin and earth plug and socket complete with one 240 volts 20 amp single pole MCB complete all as specrified & directed.
S&F in replacement of Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed . MAKE: BAJAJ, RECOLD,/ HAVELLS . ( Note: old unserviceable Geyser will be deposited in E/ M store yard )
S&F plug top 3 pin 15 Amp in repair. ISI marked. Make Anchor/ Cona/ Plaza
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
Ram Naresh Singh Sikarwar
M/S C S AITHANI
M/S SETHI BROTHERS
PAWAN KUMAR
VERDHMAN ASSOCIATES
SARASWATI CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .